Alcatel-Lucent 9130
BSC/MFS Evolution |
Installation Manual
3MN-00467-1011-RJZZA
Issue 1 | March 2012
Legal notice
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2012 Alcatel-Lucent. All rights reserved.
Note:
Contents
About this document
Purpose
............................................................................................................................................................................................. ix
ix
........................................................................................................................................................................ ix
ix
....................................................................................................................................................................... ix
ix
Intended audience
......................................................................................................................................................................... ix
ix
......................................................................................................................................................................... x
x
Prerequisites ..................................................................................................................................................................................... xx
Conventions used
........................................................................................................................................................................... x
x
Safety Information
Structure of safety statements ............................................................................................................................................... 1-1
1-1
Overview
Overview ...................................................................................................................................................................................... 2-1
2-1
Presentation ................................................................................................................................................................................. 2-1
2-1
Preparation
.................................................................................................................................................................................. 2-6
2-6
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
iii
3MN-00467-1011-RJZZA
Issue 1 March 2012
Contents
....................................................................................................................................................................................................................................
Scenario
Overview ...................................................................................................................................................................................... 3-1
3-1
Before Going Onsite
Overview ...................................................................................................................................................................................... 3-3
3-3
Before You Start
Before You Start ........................................................................................................................................................................ 3-4
3-4
Install Rack
Prepare Floor
.............................................................................................................................................................................. 3-5
3-5
............................................................................................................................................ 3-7
3-7
.............................................................................................................................................. 3-31
3-31
................................................................................................................................................................. 3-38
3-38
................................................................................................................................................ 3-41
3-41
................................................................................................................................................. 3-59
3-59
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
iv
3MN-00467-1011-RJZZA
Issue 1 March 2012
Contents
....................................................................................................................................................................................................................................
..................................................................................................................................................... 3-67
3-67
....................................................................................................................................... 3-72
3-72
...................................................................................................................................... 3-74
3-74
O7: Install Ethernet Cables for IP Telecom Traffic in Release B11 ..................................................................... 3-75
3-75
O8: Install Optical Cables for STM1 in Release B11
How to Install Optical Cables for STM1 in Release B11 ........................................................................................ 3-76
3-76
Install Optical Cables in Cable Way ................................................................................................................................ 3-77
3-77
Install SFP Modules
.............................................................................................................................................................. 3-79
3-79
............................................................................................................................................................ 3-81
3-81
Finish Installation
How to Finish Installation ................................................................................................................................................... 3-85
3-85
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
v
3MN-00467-1011-RJZZA
Issue 1 March 2012
Contents
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
vi
3MN-00467-1011-RJZZA
Issue 1 March 2012
List of figures
2-1
............................................................................................... 2-2
2-2
3-1
3-2
3-3
3-4
3-5
3-6
3-7
3-8
3-9
3-10
3-11
3-12
3-13
Bind Cables
3-14
3-15
3-16
3-17
3-18
3-19
3-20
3-21
...................................................................................................... 2-3
............................................................................................................................. 3-16
.................................................................................................................... 3-18
....................................................................................................................................................... 3-26
3-26
.................................................................................................................. 3-27
.................................................................................................................................... 3-35
................................................................................................................................. 3-36
............................................................................................................................................................... 3-41
3-41
................................................................................................................................... 3-42
............................................................................................................... 3-43
................................................................................................................................... 3-45
..................................................................................................................................... 3-46
................................................................................................................................... 3-54
..................................................................................................................................... 3-55
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
vii
3MN-00467-1011-RJZZA
Issue 1 March 2012
List of figures
....................................................................................................................................................................................................................................
3-22
...................................................................................................... 3-61
3-23
Rear View of ATCA Shelf Variant Before 3BK 27291 ABxx ................................................................. 3-62
3-24
3-25
Rear View of ATCA Shelf from Shelf Variant 3BK 27291 ABxx On
3-26
3-27
3-28
3-29
3-30
3-31
3-32
3-33
Close Doors
...................................................................................................... 3-64
................................................. 3-65
........................................................................................................................................... 3-67
3-67
................................................................................................... 3-83
.............................................................................................. 3-84
.............................................................................................................................. 3-85
............................................................................................................................................................... 3-86
3-86
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
viii
3MN-00467-1011-RJZZA
Issue 1 March 2012
Purpose
This document describes how to install onsite an Alcatel-Lucent BSS 9130 MFS/BSC
Evolution and how to install a second equipment in an 9130 MFS/BSC Evolution rack.
Reason for reissue
Issue number
Edition 01
None.
Other changes
None.
Intended audience
Installers
Site administrators
Supervisors
Project managers
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
ix
3MN-00467-1011-RJZZA
Issue 1 March 2012
No specific recommendation applies regarding the way readers should read this
document.
Safety information
For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.
Prerequisites
Conventions used
None.
Typographical conventions
Description
Italicized text
Emphasized information.
Related information
None.
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
x
3MN-00467-1011-RJZZA
Issue 1 March 2012
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatellucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
xi
3MN-00467-1011-RJZZA
Issue 1 March 2012
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
xii
3MN-00467-1011-RJZZA
Issue 1 March 2012
Safety Information
1
This topic describes the components of safety statements that appear in this document.
General structure
E
L
P
M
CAUTION
Lifting hazard
SA
F
G
H
Item
Structure element
Purpose
Safety symbol
Signal word
Hazard type
Safety message
Avoidance message
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
1-1
3MN-00467-1011-RJZZA
Issue 1 March 2012
Safety Information
....................................................................................................................................................................................................................................
Item
Structure element
Purpose
Identifier
Signal words
Meaning
DANGER
WARNING
CAUTION
NOTICE
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
1-2
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
2
Overview
Purpose
This Overview gives information needed by project managers and foremen, for
presentation to the customer and for site planning.
Contents
Presentation
2-1
Preparation
2-6
Scheduling
2-7
Resources
2-8
Presentation
Hardware Description
The following figure shows the front view of the 9130 MFS/BSC Evolution rack.
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-1
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Presentation
....................................................................................................................................................................................................................................
The following figure shows all 9130 MFS/BSC Evolution possible configurations.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-2
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Presentation
....................................................................................................................................................................................................................................
The following table gives the dimensions and weight of the cabinet.
Description
Dimensions
Width
600 mm
Depth
600 mm
1
2000 mm
Weight
Notes:
1.
Cases
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-3
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Presentation
....................................................................................................................................................................................................................................
Options
Initial State
Before the installation, the rack and installation kits are packed and delivered onsite.
Final State
Restrictions
None.
Grouped Task Sequence
The following figure shows the task sequence for dismantling onsite an Alcatel-Lucent
BSS 9130 MFS/BSC Evolution.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-4
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Presentation
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-5
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Preparation
....................................................................................................................................................................................................................................
Preparation
Prerequisites
The site must comply with the safety rules given in the General Wiring Handbook
The site is ready to receive the racks, according to the SPP 59 - Specification for 9130
BSC/MFS Evolution Site Preparation.
You must have the following specific information to complete the scenario.
Site:
Rack:
Kits:
PCM cables impedance (120-ohm, 75-ohm).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-6
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Scheduling
....................................................................................................................................................................................................................................
Scheduling
Time based on technical constraints
The number of resources shown in the table below does not take into account individual
customer or safety requirements.
Task
Time / Task
1st person
Time / Task
2nd person
15 min.
15 min.
15 min.
15 min.
15 min.
15 min.
15 min.
15 min.
15 min.
15 min.
15 min.
15 min.
15 min.
10 min.
10 min.
10 min.
10 min.
10 min.
10 min.
10 min.
10 min.
10 min.
10 min.
20 min.
20 min.
15 min.
15 min.
Total Time
2h 55 min.
2h 55 min.
Notes:
1.
The following table gives the duration for the optional tasks.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-7
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Scheduling
....................................................................................................................................................................................................................................
Task
Time / Task
1st person
Time / Task
2nd person
30 min.
30 min.
30 min.
30 min.
10 min.
10 min.
10 min.
10 min.
10 min.
10 min.
15 min.
15 min.
Resources
Tools
The following tables describe the necessary hardware tools, software tools, and forms.
Installation Kits
Use the following table to check, onsite, the mandatory or optional delivery item kits.
The following symbols apply:
mandatory kit
technical choice kit
customer option kit.
Mandatory kits
Mnemonic
Reference
Quantity
Cabinet equipped
JRXMX
3BK 27154 AA
JDMX
3BK 27244 AB
PVCABE10
1AB 060540027
PVCABE11
1AB 060540023
PVCABE13
1AB 060540026
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-8
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Resources
....................................................................................................................................................................................................................................
Reference
Quantity
JLIU75E1
JLIU75E1
JLIU75E1
CA120S
3BK 08941 AA
PC35YG1D
3BK 08960 BA
PC16BL1D
3BK 08955 BB
PC16B1D
3BK 08956 BA
PV25BL1D
3BK 08963 BA
PV25B1D
3BK 08963 BB
ALETHD
3BW 01804 JA
ALETHC
3BW 01805 JA
DDF
TERBLO1
TERBLO2
BNC connector M
BNCCON1
128
TERBLO3
BNCCON2
128
LABRAC1
JDTCO
3BK 25297 AA
EABMX
JDTCFF
3BK 25341 AA
JDSISM
3BK 25284 AA
Mandatory kits
Mnemonic
SFP modules
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-9
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Resources
....................................................................................................................................................................................................................................
Mandatory kits
Mnemonic
Reference
Quantity
JLOPT6
Depending of length:
OFC3SEC
3BK28064 GLAA
for L=15m
3BK27700ABAA
Hardware Tools
Refer to the Tools Catalogue for Field Activity for more information.
Kit name
Reference
Calibration
OUT 001
no
Forms
Supplies
The installer must supply these kits (not included in Alcatel-Lucent kits).
Item
Quantity
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-10
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Resources
....................................................................................................................................................................................................................................
Applicable Documents
You must have the following documents or have electronic access to the following
documents:
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-11
3MN-00467-1011-RJZZA
Issue 1 March 2012
Overview
Resources
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
2-12
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
3
Overview
Purpose
This Scenario presents all checks needed before beginning the scenario, and all detailed
tasks to be performed onsite.
Contents
Before Going Onsite
3-3
Overview
3-3
3-4
3-4
Install Rack
3-5
Prepare Floor
3-5
3-7
3-11
Fix Rack
3-13
3-22
3-22
3-23
3-25
3-28
3-31
3-34
3-38
3-41
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-1
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Overview
....................................................................................................................................................................................................................................
3-41
3-47
3-56
3-58
3-58
3-59
3-67
3-70
3-71
3-71
3-72
3-73
3-74
3-75
3-76
3-76
3-77
3-79
3-81
Finish Installation
3-85
3-85
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-2
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Before Going Onsite
Overview
....................................................................................................................................................................................................................................
Before going onsite, check that the following information and supplies are available:
Installation Kits (p. 2-8) are available and ready for operation
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-3
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Before You Start
....................................................................................................................................................................................................................................
Refer to the SPP 10 - Site Condition Inspection Specification (All SPG/SPP) and
complete the Site Premises Inspection Form (CEL)
Check that the safety precautions are taken in accordance with the safety instructions
described in the B11 BSS Methods Handbook
Complete the header field of the CCL. Complete the CCL as each instruction is
carried out.
Attention: Among the Cases (p. 2-3) and the Options (p. 2-4), identify which
cases and options apply to you.
Required Knowledge
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-4
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Prepare Floor
....................................................................................................................................................................................................................................
Install Rack
Prepare Floor
Overview
Note: To be compliant with EN 60950 rules, it is mandatory that the rack be fixed to
the floor (refer to SPP 59 - Specification for 9130 BSC/MFS Evolution Site
Preparation).
There are two installation cases:
Using a template, cut a rectangular hole in the tile to pass the cables.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-5
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Prepare Floor
....................................................................................................................................................................................................................................
You must:
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-6
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-7
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-8
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
A box with four Ethernet cables is delivered inside the rack. Leave the cables in the rack.
The cables are connected during commissioning.
...................................................................................................................................................................................................
On the back side of the ATCA shelf, remove metallic parts used during transportation. If
two shelves are equipped, remove the metallic parts on both shelves.
Note: If the metallic parts used for transportation are removed during the installation,
keep the parts safely onsite to be reused for transportation in the case of dismantling.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-9
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Slightly unfasten the screws fixing the JSXPDU (one or two turns).
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-10
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
....................................................................................................................................................................................................................................
Materials
Reference
Kit
JDTCO
Edge protection
JDMX
Procedure
Cut a hole in the site cable way for each used cable entry.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-11
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Follow the same procedure to install the second vertical cable way.
E...................................................................................................................................................................................................
N D O F S T E P S
No specific preparation of cable way. Use the same rules for cable separating.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-12
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Fix Rack
....................................................................................................................................................................................................................................
Fix Rack
C1: Concrete Floor Fixing
Nr
Materials
Reference
Kit
Screws HM 8 x 65 mm
(JDMX)
Washer 8 mm
The following figure shows how to level the rack then fix the rack to the concrete floor.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-13
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Fix Rack
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-14
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Fix Rack
....................................................................................................................................................................................................................................
Procedure
Materials
Reference
Kit
Screw 8 mm x 80 mm
3BK 25341 AA
Washer 8 mm
(JDTCFF)
Frame of rack
3BK 08094 AA
3BK 27244 AB
Coupling nut 8 mm
(JDMX)
Threaded rod 8 mm
Hexagon nut 8 mm
Washer 8 mm
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-15
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Fix Rack
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-16
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Fix Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Put the expanding plug (9) in the concrete floor (see Figure 3-3, Raised Floor Fixing
Example (p. 3-16)).
...................................................................................................................................................................................................
Screw the threaded rod (6), then the washer (8) and nut (7).
...................................................................................................................................................................................................
Screw the coupling nut (5) as shown in Figure 3-3, Raised Floor Fixing Example
(p. 3-16).
...................................................................................................................................................................................................
Attention: This option can be installed only with a raised floor exactly 34 cm high
from the concrete ground.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-17
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Fix Rack
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-18
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Fix Rack
....................................................................................................................................................................................................................................
Nr
Materials
Reference
Kit
Pedestal
Bracket
(JDSISM)
Screw 16 x 40
Washer M16
Screw 8 x 35
Washer M8
Nut H8
Washer M10
10
Screw 10 x 65
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-19
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Fix Rack
....................................................................................................................................................................................................................................
Assemble the earthquake frame using screw (3) and washer (4) (see Figure 3-4,
Mechanical Assembling of Frame (p. 3-18)).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-20
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Rack
Fix Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Drill the ground and fit the wall plug (8) (see Figure 3-5, Fixing Raised Floor at Same
Level of Earthquake Frame) (p. 3-20)).
...................................................................................................................................................................................................
Fix the earthquake frame using the washer (9) and screw (10).
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-21
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
DANGER
Electric-shock hazard
Risk of electrocution to personnel and damage to equipment.
Before making any electrical connections to the rack, ensure that the safety instructions
are followed.
It is essential that:
The electrical power supply is disconnected. Ensure all breakers or fuses devoted to
the new rack into the site connection box are switched OFF
The protective EARTH (GND) must be connected to the equipment before DC power
cable connection. It must be firstly connected at site side and secondly at rack side.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-22
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
The following figure shows how to install the cables in the site cable way.
Procedure
Install DC 48V power cables in the power compartment of the cable way (BATA, BATB
and BATR cables).
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-23
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-24
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
Fit the corner profile to the left or to the right of the cabinet according to the site
configuration.
...................................................................................................................................................................................................
Fix the 200 mm braid to the cable way (mechanical ground) (see Figure 3-7, Power
Cables Outlet General View (p. 3-27)).
...................................................................................................................................................................................................
Additional information
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-25
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
The following figure shows a general view of the power cable outlet.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-26
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-27
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Pass the power cables for branch A through the left cable entry.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-28
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Pass the GND cable and power cables for branch B through the right cable entry.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-29
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Cut the metallic sheet to the required length and fit a lug.
...................................................................................................................................................................................................
Run the power cables for branch A through the left cable duct to the top of the rack.
...................................................................................................................................................................................................
Run the GND cable and power cables for branch B through the right cable duct to the top
of the rack.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-30
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
Materials
Reference
Kit
90 bent lugs
Tie wrap
Label
Consumable supplies
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-31
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
Procedure
Label the site end of the GND cable (for example: 9130 MFS/BSC Evolution N 4).
...................................................................................................................................................................................................
Crimp an adapted lug at the site side and at the rack side of the GND yellow/green cable.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-32
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Before connecting to the rack, connect the yellow/green GND cable to the site earth plate.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-33
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
Materials
Reference
Kit
Labels
90 bent lugs
(JDMX)
Tie wrap
Consumable supplies
Procedure
Connect the -48 Volts blue cables to BATA and BATB studs.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-34
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-35
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-36
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-37
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
On the site power cabinet, check if DC 48 volts fuse breakers are switched OFF (BATA
and BATB).
...................................................................................................................................................................................................
On the rack side, check that all power breakers on JSXPDU are switched OFF;
otherwise switch them OFF.
...................................................................................................................................................................................................
On the rack side, check that the power breakers on all JBXPSs are switched OFF;
otherwise switch them OFF.
...................................................................................................................................................................................................
On the rack side, on the connection box, with an ohmmeter, test if there is no short
circuit between -48 volts (BATA or BATB) and 0 volts (BATR).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-38
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
On the rack side, perform the same test between the -48V cables.
...................................................................................................................................................................................................
On the site power cabinet, check that the site fuse breakers correspond to the
recommendations from SPP 59 - Specification for 9130 BSC/MFS Evolution Site
Preparation.
...................................................................................................................................................................................................
On the site power cabinet, switch ON the DC 48 volts fuse breakers (BATA and BATB).
...................................................................................................................................................................................................
On the rack side, measure if 48 V is present on the BATA and verify the polarity.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-39
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install Protective Earth and Power Supply Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
On the rack side, measure if 48 V is present on the BATB and verify the polarity.
...................................................................................................................................................................................................
10
On the site power cabinet, switch OFF the site fuse breakers.
...................................................................................................................................................................................................
11
When all power lines are checked, replace the JSXPDU covers and fix them with the
provided screws.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-40
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
Bind the cables in groups of eight cables as shown in the following figure.
Figure 3-13 Bind Cables
...................................................................................................................................................................................................
Run the group of eight cables through the cable ducts to the bottom of the rack.
...................................................................................................................................................................................................
Run the cables under the rack through the side cable entries of the rack.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-41
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Run the cables to the JSXLIU shelf through the front cable entry of the rack.
...................................................................................................................................................................................................
If a second ATCA shelf must be installed, run the cables before ATCA shelf installation.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-42
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-43
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
Run the cables through the front window in the bottom plate (see Figure 3-8, Bottom
Cable Entry (p. 3-29)).
...................................................................................................................................................................................................
If a second ATCA shelf must be installed, run the cables before ATCA shelf installation.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-44
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-45
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-46
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
For the first eight cables on each side of the rack, run the free end of the cables, from the
bottom, through the cable duct to the top of the rack.
...................................................................................................................................................................................................
If more than eight cables are required on each side, run the cables between the cable duct
and the rack back side, close to the side walls.
Attention: Ensure that the PCM cables:
Cannot be damaged when running out at the rack top (edge protection is
available).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-47
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-48
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Ensure that the PCM cables are close to the rack side panels.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-49
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-50
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Disconnect the PCM cables from the JBXLIU boards and leave them near the JSXLIU
shelf, not connected. PCM cable connection is performed during commissioning,
according to customer requirements.
E...................................................................................................................................................................................................
N D O F S T E P S
Run the cables through the front window in the bottom plate.
Note: If two JSXLIU shelves are used, the PCM cables can also be routed through the
side cable windows.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-51
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-52
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Disconnect the PCM cables from the JBXLIU boards and leave them near the JSXLIU
shelf, not connected. PCM cable connection is performed during commissioning,
according to customer requirements.
The following figures show a front and side view for the cable routing solution.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-53
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-54
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-55
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
Note: Refer to Site Specific Information (p. 2-6) to know the quantity of PCM
cables to install.
If a second ATCA shelf must be installed, install the PCM cables now for this ATCA
shelf.
Nr
Materials
Reference
Kit
Tie wraps
Consumable supplies
Note: Before starting the installation, ensure that the PCM cables have the required
length.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-56
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Install PCM Cables
....................................................................................................................................................................................................................................
Procedure
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-57
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
To install the PCM cables for the second equipment, refer to Install PCM Cables
(p. 3-41).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-58
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
Check on the rack that the 16 screws and/or nuts required for second ATCA shelf
installation are available.
...................................................................................................................................................................................................
Ensure that nothing can block the second ATCA shelf insertion in the cabinet.
...................................................................................................................................................................................................
Ensure that PCM cables for the second ATCA shelf are already installed; if they are not,
install the PCM cables before ATCA shelf installation.
E...................................................................................................................................................................................................
N D O F S T E P S
Connect the strap to the shelf by attaching the front or rear ESD jack.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-59
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Install ATCA Shelf Power Cables in Case of Shelf Variant Before 3BK 27291 ABxx
(p. 3-61)
Install ATCA Shelf Power Cables in Case from Shelf Variant 3BK 27291 ABxx On
(p. 3-64).
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-60
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
Install ATCA Shelf Power Cables in Case of Shelf Variant Before 3BK 27291 ABxx
Connect the ground and power cables to the second ATCA shelf:
...................................................................................................................................................................................................
...................................................................................................................................................................................................
Remove the M6 nuts and lockwashers from each of the connections on the JBXPSs and
set aside.
...................................................................................................................................................................................................
Install the power cables to the connections on the JBXPSs with the M6 nuts and
lockwashers previously removed. Torque nuts to 7.1 Nm (63 lbf.in).
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-61
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
Figure 3-23 Rear View of ATCA Shelf Variant Before 3BK 27291 ABxx
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-62
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-63
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
10
Install ATCA Shelf Power Cables in Case from Shelf Variant 3BK 27291 ABxx On
Connect the ground and power cables to the second ATCA shelf:
...................................................................................................................................................................................................
...................................................................................................................................................................................................
Remove the M6 nuts and lockwashers from each of the connections on the JBXPSs and
set aside.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-64
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Install the power cables to the connections on the JBXPSs with the M6 nuts and
lockwashers previously removed. Torque nuts to 7.1 Nm (63 lbf.in).
...................................................................................................................................................................................................
Figure 3-25 Rear View of ATCA Shelf from Shelf Variant 3BK 27291 ABxx On
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-65
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-66
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
Ensure that nothing can block the second LIU shelf insertion in the cabinet.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
Perform the following steps only if the shelf must be installed from the front.
...................................................................................................................................................................................................
Loosen the screws fixing the brackets at the rear of the shelf and remove the brackets.
Figure 3-26 Brackets at Shelf Rear
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-67
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Mount the fixation brackets at the front of the shelf and fix them with the screws.
Figure 3-27 Brackets at Shelf Front
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-68
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
Connect the strap to the shelf by attaching the front or rear ESD jack.
...................................................................................................................................................................................................
From the back when the existing LIU shelf is installed from the rear
From the front when the existing LIU shelf is installed from the front.
Attention: Do not hold the LIU shelf from inside; hold it by the side panels.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-69
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O2: Install Second Equipment in Rack
....................................................................................................................................................................................................................................
Connect the first JLCAT6 Ethernet cable (1AB 22983 0005) between ATCA shelf 4,
JAXSSW1, Ethernet port 2 and the GbE port on JBXMUX1 (slot 10) in JSXLIU shelf 2.
...................................................................................................................................................................................................
Connect the second JLCAT6 Ethernet cable (1AB 22983 0005) between ATCA shelf 4,
JAXSSW2, Ethernet port 2 and the GbE port on JBXMUX2 (slot 12) in JSXLIU shelf 2.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-70
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O3, O4, O5, O6, O7: Install Ethernet Cables
....................................................................................................................................................................................................................................
Materials
Reference
Kit
Labels OMC-R
Ethernet cables
OMC-R Ethernet
cables (ALETHD)
3BW 01804 JA
Procedure
Install the OMC-R (and CBC for the 9130 BSC Evolution) router cables:
...................................................................................................................................................................................................
Refer to Site Specific Information (p. 2-6) for quantity and cabling of OMC-R cables.
...................................................................................................................................................................................................
Pass the cables into the cabinet the same way as for PCM cables.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-71
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O3, O4, O5, O6, O7: Install Ethernet Cables
....................................................................................................................................................................................................................................
Materials
Reference
Kit
Labels A-GPS
Ethernet cable
A-GPS Ethernet
cables (ALETHD)
3BW 01804 JA
Procedure
Refer to Site Specific Information (p. 2-6) for quantity and cabling of A-GPS cables.
...................................................................................................................................................................................................
Pass the cables into the cabinet the same way as for the PCM cables.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-72
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O3, O4, O5, O6, O7: Install Ethernet Cables
....................................................................................................................................................................................................................................
Materials
Reference
Kit
Labels EAB
Ethernet cable
3BW 01804 JA
Procedure
Pass the cable for EAB into the cabinet in the same way as for the PCM cables.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-73
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O3, O4, O5, O6, O7: Install Ethernet Cables
....................................................................................................................................................................................................................................
Materials
Reference
Kit
Labels SGSN
Ethernet cables
SGSN Ethernet
cables (ALETHD)
3BW 01804 JA
Procedure
Refer to Site Specific Information (p. 2-6) for the quantity and cabling of SGSN cables.
...................................................................................................................................................................................................
Pass the cables into the cabinet the same way as for the PCM cables.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-74
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O3, O4, O5, O6, O7: Install Ethernet Cables
....................................................................................................................................................................................................................................
Materials
Reference
Kit
Labels IP telecom
traffic Ethernet
cables
IP telecom traffic
Ethernet cables
(ALETHD)
3BW 01804 JA
Procedure
Pass the cables into the cabinet the same way as for the PCM cables.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-75
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O8: Install Optical Cables for STM1 in Release B11
....................................................................................................................................................................................................................................
Note: This task must be performed only if the STM1 option was selected at BSC side.
An optical fiber cable (patch cord) is a very sensitive object. Please handle it with
care.
When routing the optical fiber cables, ensure that the bending radius is higher than the
minimum bending radius provided by the manufacturer. Generally the bending radius
of a optical cable is greater than 20D, where D is the diameter of cable.
Follow the manufacturer's recommendations.
Refer to Site Specific Information (p. 2-6) for the number of STM1 cables to install.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-76
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O8: Install Optical Cables for STM1 in Release B11
....................................................................................................................................................................................................................................
Materials
Reference
Kit
Basic installation
kit for Optical Fibre
cable
3BK27700ABAA
Consumable supplies
Procedure
Install the optical cables in the STM1 compartment of the cable tray.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-77
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O8: Install Optical Cables for STM1 in Release B11
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-78
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O8: Install Optical Cables for STM1 in Release B11
....................................................................................................................................................................................................................................
Replace the protective rubber from the SFP module and insert straight into the slot until
the module clicks firmly into place. When inserting the SFP, be sure that the hinged face
is closed.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-79
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O8: Install Optical Cables for STM1 in Release B11
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-80
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O8: Install Optical Cables for STM1 in Release B11
....................................................................................................................................................................................................................................
Note: The optical fiber cable cannot be cut to the correct length. You must therefore
adjust the cable length by making loops with the cable in the rack or cable tray.
C1: Route Optical Cables by Top Entry of Rack
...................................................................................................................................................................................................
Run the optical cables at the back of the rack from top to bottom. Attach the optical cables
with plastic tie wraps.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-81
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O8: Install Optical Cables for STM1 in Release B11
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
From the bottom of the rack pass optical cable in front of the rack, route them until you
reach front of the JBXTP3 boards. Attach the optical cables with plastic tie wraps from
this point. Refer to Figure 3-31, Optical Cable Connection on JBXTP3 Board (p. 3-84).
E...................................................................................................................................................................................................
N D O F S T E P S
Note: The optical fibre cable cannot be cut to the correct length. You must therefore
adjust the cable length making loops with the optical cable in the rack or cable tray.
Perform the following steps:
...................................................................................................................................................................................................
Run the optical cables from the bottom of the rack to the front side of the JBXTP3.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-82
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O8: Install Optical Cables for STM1 in Release B11
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-83
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
O8: Install Optical Cables for STM1 in Release B11
....................................................................................................................................................................................................................................
The following figure shows the optical fibre cable connection positions on the front plate
of the JBXTP3 boards.
Figure 3-31 Optical Cable Connection on JBXTP3 Board
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-84
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
....................................................................................................................................................................................................................................
Finish Installation
How to Finish Installation
Procedure
...................................................................................................................................................................................................
Fit the labels to the rack (for example: 9130 MFS/BSC Evolution n12).
...................................................................................................................................................................................................
Close the front door and leave the rack key to the door with the customer.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-85
3MN-00467-1011-RJZZA
Issue 1 March 2012
Scenario
Finish Installation
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Clean the site. Do not put packages into the customer bin.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC/MFS
3-86
3MN-00467-1011-RJZZA
Issue 1 March 2012