MM-ENDObook
04 Working length
07 Speed and torque
10 Endodontic treatment
22 Endodontic retreatment
25 Obturation
Discover
MICRO-MEGA
solutions,
developed for you
and with you
All our savoir-faire
for your comfort
and that of your
patients!
Supporting you...
MICRO-MEGA, a hundred-year-old French company, possesses savoir-faire that is
recognized worldwide in the fields of the design, manufacture and sale of dental surgical
instruments (root canal instruments, obturation, hand instruments and instrument hygiene).
MICRO-MEGAs savoir-faire in the design and construction of its own production machinery
has helped to achieve a predominant position in the dental instrument world. Over the years,
MICRO-MEGA has become a leader and undisputed specialist in endodontics.
Its mission is to innovate in this field, setting the standards for general dental practitioners
throughout the world and offering the dental market a unique range of technical and scientific
expertise. Its motto Your Endo Specialist perfectly reflects this mission.
The MM-ENDOBook, dedicated to endodontics, will guide you through each stage of the
treatment, retreatment and obturation.
Simple to use
Reliable
Time-saving
Working
length
n
The first exploration of the root canal is done with a pre-curved
steel hand instrument, which provides information on canal
anatomy. The importance of the mineralisation of the root canal
lumen and the curve determine the difficulty of the treatment
and therefore thechoice of the sequence best suited to the
clinical case.
n
Apex locators have become indispensable tools in endodontics.
They allow you to reliably determine working length and their
results complement those obtained by pre-operative x-rays and
the manual determination carried out with a K file (MMCn10
L21 mm for example).
Working length
MMC files
How to effectively assess the root canal anatomy?
Passing a manual file coated with MM-EDTA Cream is the first indispensable step in any successful
endodontic treatment. The use of MMC files offers excellent precision and simplicity.
10
Color code
15
Individual sizes
06 15
Assortment by box 08 15
N
umber
identification
n
n
n
n
S
ilicone stop
radio-opaque
P
re-curvature Parachute
mark
Hang on
Instrument
identification
Apex Pointer +
Pre-apical zone
1 Carefully
insert the file into the
3
n
n
n
n
n
n
Apical constriction
2
zone 23
2 The4 scale
is divided
4 into 5
segments between the apical
constriction and the apex.
Inserting the file deeper will
increase beep sensitivity. One
segment has a clear round
spot towards the bottom
of the scale. This means a
reading of 0.5 and indicates
the apical constriction.
Apical zone
(foramen)
Speed
and torque
n
The use of Nickel-Titanium files requires total compliance with
the recommended protocol and speed, in order to optimize
the effectiveness of your instruments and limit the risk of
breakage in the canal.
Endo Contra-angles
AXS Endo
n 3 reduction ratios
InGeT
n 3 reduction ratios
InGeT 04 (100:1)
InGeT 06 (75:1)
InGeT 08 (50:1)
n
Improved visibility
of the operating field.
n
Lightweight, outstanding
ergonomics, even easier
to handle.
n Exceptional working comfort.
Standard
head
InGeT
Microhead
Superimposed
heads
Simple head
mechanism
Endo Motor
Speed and torque
MMcontrol
Endo motor with torque and speed control +
integrated apex locator. MMcontrol is the
indispensable tool in endodontics which
offers reliability, simplicity and safety.
Proven reliability
n Controls the speed which remains stable according
the apex.
n Torque control + auto-reverse of rotation
Simplicity of use
n Easy to use: simple and intuitive interface.
n Space saving all-in-one device: no need to buy
Use in continuous
rotation
n A principle with
scientifically proven
efficiency versus
reciprocation.
n Apical debris extrusion
with reciprocating
movement is higher than
with continuous rotation.
Literature
references
Apically extruded debris
with reciprocating single-file
and full-sequence rotary
instrumentation systems.
Brklein S., Schfer E. /
JOE 2012 June
Quantitative evaluation of
apically extruded debris with
different single-file systems:
Reciproc, F360 and One Shape
versus Mtwo. Burklein, Shaefer
& Benten / IEJ 2013 July 6
Endodontic
treatment
n Reliable and practical tools to make every step of treatment easier
by conforming to the biological and ergonomical requirements of
disinfecting and shaping.
n Simple protocols for more efficiency.
n Saving time at every stage.
Scientific articles:
One Shape
10
ENDOFLARE
n
n
n
n
n
3
4
Irrigate generously.
Endodontic
treatment
Additional information to this protocol for use: refer to regulatory and legal information (pages 42-43)
Classics or InGeT
.12 - n25 - L 15 mm
11
G-Files
How to prepare access for rotary instruments rapidly and in complete safety?
Glide path development is an essential but time-consuming step in endodontic treatment. G-Files are
based on an innovative design to help the clinician safely save time in endodontic procedures. The
superior cross-section of the G-Files combines efficiency and innovation. Along the length of the
instrument, the G-File has cutting edges on three different radiuses leaving a large and efficient area
for upward debris removal.
Used after hand files have measured working length, G-Files safely enlarge the glide path in preparation
for RCT with rotary instrumentation system.
G1
G2
-N
Only
.03
L2
1,
25
or
-N
12
29
.03
+
L2
1, 2
5o
r 29
mm
mm
instruments!
Pack of 4 assorted
instruments
Classics
or InGeT
G1 x 2 + G2 x 2
L 21, 25 or
29 mm
Pack of 4 identical
instruments
n
Superior flexibility due
to their small instrument
diameters (n 12 and n 17)
and their slight .03 taper.
n
Non-working (safety) tip.
n
Optimized electropolishing
offers excellent cutting
efficiency and enhances
penetration of the file down
to the apex.
n
Enhanced circulation of the
irrigation solution beginning
from the initial phase
of treatment.
n
Quickly and safely enlarge
the canal passageway
to the apex.
12
Additional information to this protocol for use: refer to regulatory and legal information (pages 42-43)
File K
(MMC)
G1
G2
WL
WL
stainless-steel
instrument
(MMC08 and 10 files).
Endodontic
treatment
R1
R2
R3
Non-working Tip
13
One Shape
On Ne
eS w
ha
pe
Blister of 5 identical
instruments
Classics
14
.6 - n25
L 21, 25
or 29 mm
Additional information to this protocol for use: refer to regulatory and legal information (pages 42-43)
Simplicity of use
Efficiency
Safety
Flexibility
packaging.
n Respect of office hygiene.
Endodontic
treatment
effect.
n Minimal fatigue along the length of the file
Literature
references
Apically extruded debris
with reciprocating single-file
and full-sequence rotary
instrumentation systems.
Brklein S., Schfer E. /
JOE 2012 June
Quantitative evaluation of
apically extruded debris with
different single-file systems:
Reciproc, F360 and One Shape
versus Mtwo. Burklein, Shaefer
& Benten / IEJ 2013 July 6
15
The first zone presents a variable 3-cutting-edge design.
The second (transition zone) has a cross-section that
progressively changes from 3 to 2 cutting edges.
The last (coronal) is provided with 2 cutting edges.
The instrument presents a variable asymmetrical crosssection along the blade.
n Examples of instrument cross-section evolution.
Apical zone
Asymmetrical cross-section
MICRO-MEGA patent
since 1999.
n Longer pitch.
n Variable cross-section along
the instrument.
n Depth identifications on the file.
n
Coronal zone
Operating Protocol
16
Take
a preoperative radiograph to assess canal anatomy and establish Estimated Working
Length (EWL).
Remove coronal constrictions with ENDOFLARE (or use your current flaring technique). Canal
penetration of ENDOFLARE is limited to 3 mm below the pulp chamber floor.
3 mm
NaOCl
K-File
Scout
each root canal with small diameter hand files which provide information
about the root canal anatomy complementary to that obtained by the preoperative
X-rays.
Prepare
the glide path using #10 Stainless Steel K-type hand file (for example
MMC 10).
K-File
(MMC)
N10
(MMC)
N15
a) If the #10 K file easily reaches the EWL, and if it is possible to take
a #15 K file down to this EWL:
b) If canal constrictions prevent the #10 K file from easily reaching the
EWL: complete glide path preparation using G-Files, NiTi files for glide path
development in continuous rotation. Use G1 to EWL followed by G2 to EWL:
G1
(MMC)
N10
NaOCl
G2
EWL
EWL
NaOCl
EWL
Endodontic
treatment
K-File
EWL
EWL
One Shape
One Shape
Withdrawal
and cleaning
of the file
Patency check
(#10 K file)
One Shape
Withdrawal
and cleaning
of the file
Patency check
(#10 K file)
2/3 WL
NaOCl
WL - 3 mm
NaOCl
WL
17
Optional
instruments
18
19
20 mm
mm
22
mm
are proposed:
19
20 mm
mm
22
mm
n
Sterile and single-use files.
n
Efficient enlargement of the apical zone after One Shape instrumentation.
n
Apical preparation shaping respecting the path.
n
Respect of the apical constriction.
n
Superior debris removal.
n
Minimal fatigue along the length of the file virtually eliminates the risk
of separation.
Additional information to this protocol for use: refer to regulatory and legal information (pages 42-43)
Operating Protocol
One Shape
One Shape
NaOCl
NaOCl
WL
NaOCl
WL
Endodontic
treatment
WL
Working movement identical to One Shape technique: in and out movement without pressure in the apical zone.
n
One Shape Apical 2 for use after One Shape Apical 1 WL.
In case of resistance or slight apical pull remove and clean the instrument and irrigate the root canal.
This instrument is for single use and intended for the treatment of only one tooth.
Check the condition of the instrument after the treatment of each canal and dispose of all instruments which show signs
of unwinding, wear or premature fatigue. In case of reutilization the instrument presents a risk of separation. The root canal
must be irrigated using sodium hypochlorite after each instrument passage.
19
Revo-S
n Enables a better root canal penetration due to a snake-like movement = excellent progression of the
instrument toward the apical region of the root canal.
n Facilitates the elimination of debris upward the coronal thanks to the increased available volume for debris.
n Avoids the grooves to be obstructed and thus avoids the extrusion of debris beyond the instrument tip
and apical foramen.
n Reduces the stress on the instrument thanks to the rippling movement of the file along the canal walls: no
screwing effect, more flexibility, better ability to negotiate curves.
1) Cutting
2) Debris elimination
3) Cleaning
R2
R3
R1
Clockwise
Asymmetrical section
Symmetrical section
The 3 cutting edges are located to the canal axis on 3 different radiuses: R1, R2 and R3.
20
Additional information to this protocol for use: refer to regulatory and legal information (pages 42-43)
SU
SC2
(Shaper Universal)
N25 .06
L 21, 25 or 29 mm
Endodontic
treatment
SC1
2/3 WL
WL
WL
n Excellent cleaning.
n Adapted active length.
n The extended cutting part in the coronal region increases instrument flexibility.
n Facilitates the upward elimination of dentine debris.
21
Revo-S
AS 30
AS 35
AS 40
Apex 30/100
Apex 35/100
WL
22
Apex 40/100
WL
WL
n Shaping down to the working length: more accurate finishing of the apical 1/3.
n Efficient disinfection: The irrigating solution penetrates to the apical 1/3.
n The extended helical machining up to the coronal region enables a continuous bending of
the instrument.
Operative dynamics
Endodontic
treatment
n Revo-S instruments should be used with a rotation speed ranging between 250 and 400 rpm.
lU
se SC1 with slow and unique downward movement in a free progression and without pressure.
l Use SC2 with a progressive 3 wave movement (up and down movement).
l Use SU with a slow and unique downward movement in a free progression and without pressure. Then check
apical patency and if necessary, perform an upward circumferential filing movement.
n The AS instruments should be used without apical pressure, after using the SU. Their penetration depth
corresponds to the working length. This length is shortened in thin root canals or with a marked curvature. They
are then used in a step back motion (AS30 at WL, AS35 at WL 0.5mm, AS40 at WL 1mm if necessary).
Irrigation
n The canal should be thoroughly irrigated using sodium hypochlorite (2.5% to 5%) between the use of each
instrument. The use of a chelating colloid gel (MM-EDTA Cream recommended, see p. 41) is advised for
instrument lubrication and dentine debris removal.
Pack of 6assorted
instruments
Classics
or
InGeT
SC1 + SC2
+SU + AS30
+AS35 + AS40
Pack of 6identical
instruments
SC1, SC2,
SU, AS30,
AS35 or
AS40
L 21 mm L 21, 25 or 29 mm
.06
.04
.06
N25
SC1
SC2
SU
N30
AS30
N35
AS35
N40
AS40
Pack of 3assorted
instruments
SC1 + SC2 + SU,
AS30 + AS35 + AS40
23
Kits MMcontrol
One Shape Total Solution: a gain in efficiency and simplicity!
MMcontrol
+ One Shape
Solution Kit
Ref. 51400104
n 1
MMcontrol
blister MMC 08 (sterile - L25 mm)
+ 1 blister MMC 10 (sterile - L25 mm)
+ 1 blister MMC 15 (sterile - L25 mm)
n 1 blister ENDOFLARE (sterile L25 mm)
n 1 blister G-Files G1 (sterile L25 mm) + 1 blister G-Files G2
(sterile - L25 mm)
n 1
24
n 5
MMcontrol
+ Revo-S
Solution Kit
Ref. 51400103
n 1
MMcontrol
packs MMC ass 08-10-15 L 25 mm
n 1 pack ENDOFLARE - L 25 mm
n 1 pack G-Files G1 - L 25 mm
+ 1 pack G-Files G2 - L 25 mm
n 3 packs Revo-S SC1 - L 21 mm
+ 3 packs Revo-S SC2 - L 25 mm
+ 3 packs Revo-S SU - L 25 mm
n 5
n 1
25
Endodontic
retreatment
n Endodontic retreatment (ERT) is indicated following the failure
of an initial endodontic treatment.
Scientific articles:
Effectiveness, flexibility adapted to each canal zone, parietal cleaning of root canals, respect of the initial canal path, rapidity, operating
comfort, simplicity and ergonomics, safety and finally asepsis are the major advantages of the R-Endo concept, which allows
endodontic retreatments to be carried out with a great deal of serenity.
26
R-Endo
Lime Rm
N25 .04
N25 .12
n 1 /4 turn with
pressure directed
towards apex.
n Removal.
Re
R1
N25 .08
R2
N25 .06
R3
N25 .04
Endodontic
retreatment
Additional information to this protocol for use: refer to regulatory and legal information (pages 38-39)
n In curved canals:
S
ame precaution as for any kind of NiTi
instrument must be observed to avoid
false canal creation.
Introduction of a pre-curved hand
file MMC n10 is necessary prior to
penetration with R-Endo files.
27
R-Endo
Rm
Re
R1
R2
n Files specially
designed for ERT.
n Rapid: only 5 NiTi
instruments (Rm,
Re,R1, R2, R3).
n Simple: a protocol
that is easy to
memorize.
n Safe: inactive tips.
R3
Pack of
6 Rm hand files
.04
Introductory package
Pack of
5assorted
R-Endo InGeT
Re
R1
R2
28
Rs
Pack of
6 identical R-Endo
InGeT
R1
Pack of 3
assorted R-Endo
Classics
R3
R2
R3
Classics
Obturation
n Obturation guarantees the threedimensional
sealing of canals and conditions the
success of the endodontic treatment in the
long term.
n Whether temporary or permanent, obturation is
an important stage for which MICRO-MEGA
has developed reliable, practical tools that will
make your job easier.
Scientific articles:
Comparatively to similar techniques and materials, the modifications added to the HEROfill are likely to
improve its success, allowing a quick and simple three-dimensional obturation.
29
MM-MTA
n
Biocompatibility.
n
Formation of
a protective
waterproof layer,
resistant to
bacterial infiltration.
n
Excellent adhesion
to the dentine.
n
Optimal results,
even in humid
conditions.
n
Radiopacity.
30
Intended uses
MM-MTA is used in the following cases:
n
Repair of root perforations during
an endodontic treatment.
n
Root-end fillings
n
Pulp capping.
Innovative characteristics
Thanks to its unique characteristics, MM-MTA offers indisputable advantages compared to other
existing materials:
An adapted packaging:
n
Consisting of capsules containing MM-MTA powder and liquid, automatic mixing is achieved quickly with a
vibrating mixer. In addition, the resulting MM-MTA blend is extremely homogenous with transformation properties
which are always optimal and reproducible.
n Each capsule contains the exact dosage of MM-MTA to avoid waste.
A homogenous consistency:
n MM-MTA packaging insures a consistently high-quality product mix for simple handling and easy placement
Obturation
Simple, quick
31
MM-Paste
How to temporarily obturate reliably and precisely?
MM-Paste for:
n Temporary antiseptic obturation of infected canals (acute or chronic infection).
n Temporary obturation between sessions.
n Temporary obturation of canals in the case of root fracture.
After preparing the root canal, clean it and dry it. Fit a single-use nozzle on the syringe and introduce it into the canal
(1). Press on the piston and completely fill the canal, withdrawing the nozzle from the latter gradually (2 and 3). Clean
away the excess coronal paste using sterile cotton wool.
32
n
n
n
n
n
Pastinject
Pastinject
Plastic handle
L 21-25-29 mm
15
20
25
30
35
40
Individual Sizes 15 40
Assortment by box 25 40
n Its great flexibility allows it to perfectly follow the shape of the canal.
n The instruments helical shape creates a translational movement,
facilitates the transport of the filling material and guarantees
its perfect application onto the canal walls.
Obturation
33
HEROfill
Select
the
appropriate
size
HEROfill obturator.
Generally this will
be the same size
as the last file used
at the apex of the
canal.
After
the
tone,
remove the HEROfill
obturator.
Without
twisting the handle,
immediately insert it
into the canal to the
working distance.
34
n
n
n
n
n
Obturators
20
25
30
35
Verifiers
40
45
20
25
30
35
40
45
Detachable handle.
Adjustable working length.
Easy control owing to the HEROfill Verifiers.
Rapid heating with HEROfill Oven.
Easier post space preparation.
How to perfectly obturate radicular canals after shaping with One Shape?
MICRO-MEGA developed reliable and practical tools to simply obturate after shaping with One Shape.
Apical 1
Apical 2
Shaping
n Radio-opaque.
n Easy to introduce.
n Flexible for perfect adjustment to all root canal
anatomies without bending.
n Easy-to-identify thanks to the coloured tip.
n Special taper adapted to One Shape.
60 points per box. L29 mm.
Apical 1
Apical 2
Shaping
Obturation
35
Revo-S Obturation
AS30
AS35
SU
Improved
efficiency
owing to the Revo-S
Paper Points! Their taper
perfectly matches canals
shaped with Revo-S
files and thus guarantees
quick, efficient and safe
drying.
AS40
n Easy-to-identify owing to
the same colour code as
Revo-S.
n For quick, efficient and
economical drying: Less
paper points are needed
to dry the canals thanks
to their adapted taper.
Revo-S GP Points
The new Revo-S GP Points have been designed with specific tapers
and diameters perfectly matching the Revo-S files.
AS30
SU
AS35
AS40
36
Revo-S GP Points SU
Revo-S GP Points AS30
Revo-S GP Points AS35
Revo-S GP Points AS40
Revo Spreaders
Revo Condensor
NiTi Spreaders
NiTi Thermocompactor
20
25
L 25 or 29 mm
30
n
n
Additional information to this protocol for use: refer to regulatory and legal information (pages 42-43)
Obturation
L 21 or 25 mm
37
Revo-S Obturation
Lateral condensation
technique
WL
Thermomechanical
condensation technique
WL
38
WL
WL -2 mm
WL
Combined condensation
technique
WL
2
WL -2 mm
WL
Obturation
39
The Micro-Mega +
HERO Shaper
MM-GP Points
.02, .04 and .06
MICRO-MEGA also offered MM-GP Points, gutta percha points with .02, .04 and .06 tapers to obturate root canals prepared
with NiTi instruments. Their shaped makes possible to use lateral, thermomechanical or combined condensation techniques.
40
n Radio-opaque.
n Easy to introduce.
n Highest precision for all filling techniques:
cold, warm or thermomechanical
condensation techniques.
MM-Seal
n Excellent biocompatibility.
n Can be worked for 35 minutes at 23C.
n Sets in 45 minutes at 37C, allowing stress-free
placement of gutta percha cones.
MM-EDTA Cream
EDTA Cream
MM-EDTA Cream ensures effective cleaning and shaping of the root canal
system. Its lubricating action smoothes file penetration and facilitates the
removal of debris.
41
MM-ENDObook
Regulatory information
InGeT P. 8
G-Files P. 12
Revo-S P. 18
Advertising
0459
MMC Files P. 5
Advertising
Year of CE-marking: 1998
Medical device class I according
to directive 93/42/EEC
Medical device for dental care,
meant for professional dental use only.
See product labelling and, where
applicable, instructions for use.
Apex Pointer + P. 6
Advertising
0459
AXS ENDO P. 8
Advertising
0459
ENDOAce P. 9
Advertising
0459
ENDOAce Torque P. 9
Advertising
0459
ENDOFLARE P. 11
Advertising + Protocol for use
0459
42
STERILE EO
0459
Sterile devices
0459
Sterile devices
One Shape P. 14
R-ENDO P. 23
0459
Sterile devices
0459
Sterile devices
MM-MTA P. 26
Advertising
0459
MM-Paste P. 28
Advertising
0459
Pastinject P. 29
Advertising
0459
HEROfill P. 30
Revo-S Obturation P. 36
Revo-S Paper Points
Advertising
0459
0459
Advertising
0459
0459
MM-Seal
Advertising
0459
Revo-S GP Points
Advertising
0459
Advertising
Year of CE-marking: 2000
Medical device class IIA according
to directive 93/42/EEC
Certifying body: LNE/G-MED
Medical device for dental care,
meant for professional dental use only.
See product labelling and, where
applicable, instructions for use.
Revo Condensor
Revo-S Obturation P. 38
Revo Spreaders
Advertising + Protocol for use
Year of CE-marking: 2011
Medical device class I according
to directive 93/42/EEC
Medical device for dental care,
meant for professional dental use only.
See product labelling and, where
applicable, instructions for use.
Maximum number of uses indicated
on the product labeling.
The MICRO-MEGA + P. 40
HERO Shaper
Advertising
0459
MM-EDTA Cream
Advertising
0459
Non-sterile devices
43
Micro-Mega
5-12, rue du Tunnel
25006 Besanon Cedex - France
Tel.: +33 (0)3 81 54 42 34
Fax: +33 (0)3 81 54 42 39
mmid@micro-mega.com
www.micro-mega.com
Join us
on Facebook
MICRO-MEGA reserves the right to modify the characteristics of its instruments without advance notice.
Non contractual pictures
You
With
JC.AUG n www.jcauge.com
110
Years