Guidelines for Acoustic Induced Vibration (AIV), Flow Induced


Vibration (FIV) Analysis
By A JAD

Introduction
The scope of this topic is to define the design criteria and guidelines to be used for Design & Supporting for lines prone to Acoustic
Induced Vibration (AIV) & Flow Induced Vibration (FIV), especially with regard to small bore connections, in line with EI (Energy
Institute) Guide lines. This topic does not address lines subjected to other types of vibrations, such as vibrations due to pulsation,
mechanical excitation, wind, earth quake etc.
High Frequency Acoustic Excitation more commonly referred to as Acoustic Induced Vibration (AIV).
Flow Induced Turbulence more commonly referred to as Flow Induced Vibration (FIV).

Abbreviations
AIV

Acoustic Induced Vibration

DLF

Dynamic Load Factor

EI

Energy Institute

FIV

Flow Induced Vibration

LOF

Likelihood of Failure

NPS

Nominal Pipe Size

IFC

Issued for construction

SIF

Stress Intensification Factor

SBC

Small Bore Connections

TPI

Third party Inspection

References
Energy Institute (EI) Guide lines: Guide Lines for the Avoidance of Vibration Induced Fatigue Failure in Process Pipe Work.

6/24/2014 6:06 AM

Guidelines for Acoustic Induced Vibration (AIV), Flow Induced Vibration...

2 of 8

http://www.piping-engineering.com/acoustic-induced-vibration-aiv-flow-...

ASME B31.3: Process Piping

Description of Activities
4.1 Acoustic Induced Vibration
a) Acoustic Induced Vibration AIV Definition
Acoustic Induced Vibration (AIV) is generally applicable to lines in gas service. In a Gas System, high levels of high frequency
acoustic energy can be generated by a pressure reducing device such as a Relief valve, Control valve or Orifice plate. The amplitude of
this energy is governed primarily by the Flow rate & Pressure drop. Excitation due to this can lead to fatigue failure of welded
downstream connections. Piping downstream of Pressure reducing devices as below is prone to Acoustic Induced Vibration AIV.
Relief Valves.
Blow Down valves & Restriction Orifices.
Pressure reducing Valves.
Compressor recycle Valve.
Choke Valve.
b) Impact of Acoustic Induced Vibration AIV
Acoustic Induced Vibration can lead to Fatigue failure at Small Bore branches.
c) Mitigation of Acoustic Induced Vibration AIV
Detailed Acoustic Induced Vibration AIV study shall be carried out by AIV Consultant based on the Multidiscipline responsibility
Matrix as per Appendix-1. The study recommendations shall be incorporated in the design of Piping Systems.
Generally the study recommendations will be available at a later stage of the Project. In order to minimize the modifications due to
Acoustic Induced Vibration AIV Consultants recommendations, the following guidelines shall be followed during initial design of lines
prone to AIV.
Process to identify Acoustic Induced Vibration AIV Prone lines in Line list, at early stage of the Project.
A separate Pipe Class may be used for Flare system.
Generally after Acoustic Induced Vibration AIV study, the Consultant comes up with typical recommendations such as increase
of Pipe wall thickness particularly, for low wall thick Flare lines, Sweepolet branch fitting in place of weldolet, forged lateral/ 90
Deg Tee in place of stub in lateral/ 45 Degree connections, Full encirclement pad for supports at PSV outlets etc. In case of
reinforced Stub-in connection, consideration shall be given to Clause 304.3.5 (b) of ASME B31.3 regarding use of Tee fittings or
complete encirclement types of reinforcement for branch stub-in connection.
As this will have impact on material procurement & design, the study shall
be expedited & provision for incorporation of such
recommendations shall be kept to the extent possible in preliminary piping design itself.
For high energy level PSVs like Slug Catcher/ Export Line PSVs, in low wall thick piping, D/T (Diameter/Thickness) ratios of
pipes shall be reviewed & D/T<= 72 is recommended along with use of Sweepolets in place of weldolets. However, this needs to
be reviewed during initial Piping bulk procurement stage in consultation with Acoustic Induced Vibration AIV Consultant &
Project Management.
SBC tappings (2 & below) shall be braced back to header by 2-plane bracing. In header pipe sufficient spool shall be provided
to accommodate this bracing support. Bracing supports shall be from the main pipe, thus ensuring that the small bore connection
moves with the main pipe during start up, thermal transients and vibration. Small bore connections shall not be braced from a
local structure such as steel work, Decks etc. Any mass at the free end of a cantilever shall be supported in both directions to the
axis of the small bore. Any possibility of reducing mass at the free end of cantilever also to be considered. (E.g. using mono block
/ slim line valves instead of 2 separate block and bleed valve arrangement.)
Pipe wall thickness for flare systems shall be agreed with Consultant at early stage of Project, particularly in low wall thick lines.
Type of Branch fittings for Acoustic Induced Vibration AIV prone lines shall be agreed with Consultant at early stage of Project.
For Small bore standout connections, the branch fitting and overall unsupported length shall be as short as feasible.

6/24/2014 6:06 AM

Guidelines for Acoustic Induced Vibration (AIV), Flow Induced Vibration...

3 of 8

http://www.piping-engineering.com/acoustic-induced-vibration-aiv-flow-...

In certain cases use of clamped Pipe shoes will be recommended by Acoustic Induced Vibration AIV Consultant for flare system.
In such cases, specific confirmation shall be taken from Consultant for the locations where this is mandatory & at other locations
confirmation for use of welded shoes shall be taken, as clamped shoes, especially in higher sizes 24 & above are to be avoided.
In Flare lines from outlet of Flare Knock out Drum to Flare Stack, confirmation for use of welded shoes shall be taken from
Acoustic Induced Vibration AIV Consultant.

Provide Axial Stop support very close to relief valve at PSV outlet lines, with full encirclement pad.
Provide Hold Down support & Guides for Flare lines.
Support span for flare lines for offshore platforms especially running on bridge to be determined at early stage of design to
finalize bridge structural drawings.
Low noise trim, if used by Instrumentation, the same shall be informed to Acoustic Induced Vibration AIV Consultant to include
in Acoustic Induced Vibration AIV calculations which will help to reduce Acoustic Energy levels in the system.
Avoid Spool between PSV inlet/outlet Flange & reducers at upstream & downstream of relief valves, Blow down valves.
Minimize use of Trunion supports.
Any fastenings used shall be designed to be effective under vibration such as providing lock nuts etc.
Particular care shall be taken when adopting small bore supports that are welded to the connection and its main pipe as these
welds provide additional sites for fatigue failure. Dressing of welds by grinding shall be recommended and discussed with
Construction & QC.
Clamp type supports rely on bolted arrangements. Periodic inspection at field shall be recommended to ensure that no loosening
occurs during years of operation.
For lines where Acoustic Insulation is recommended, Support selection shall be as per support codes suitable for Acoustic
Insulation, as mentioned in Pipe Support Standard.

4.2 Flow Induced Vibration


a) Flow Induced Vibration - FIV Definition
Turbulence due to flow depends on flow regime. The main sources of turbulence are flow discontinuities in the system. This in turn
generates high levels of broad band Kinetic Energy which can propagate through the Piping system. This leads to excitation of low
frequency vibration modes of the pipe work causing vibrations of piping and in some cases pipe supports, which is generally referred to
as Flow Induced Vibration FIV.
b) Impact of Flow Induced Vibration - FIV
Flow Induced Vibration can lead to Fatigue failure at Small Bore branches.
c) Mitigation of Flow Induced Vibration - FIV

6/24/2014 6:06 AM

Guidelines for Acoustic Induced Vibration (AIV), Flow Induced Vibration...

4 of 8

http://www.piping-engineering.com/acoustic-induced-vibration-aiv-flow-...

Detailed Flow Induced Vibration FIV study shall be carried out by the Consultant based on the multi discipline responsibility Matrix as
per Appendix-1.The study recommendations shall be incorporated in the design of Piping Systems.
Generally the study recommendations will be available at a later stage of the Project. In order to minimize the modifications due to
Flow Induced Vibration FIV requirements the following guidelines shall be followed during initial design of lines prone to Flow
Induced Vibration FIV.
Process to Identify Flow Induced Vibration FIV prone lines at the beginning of the project.
Generally after Flow Induced Vibration FIV study, the Consultant comes up with typical recommendations such as Sweepolet
branch fitting in place of weldolet, Brace supports for SBCs etc. As this will have impact on material procurement, the study shall
be expedited & provision for incorporation of such recommendations shall be kept in piping deign. Bracing supports shall be from
the main pipe, thus ensuring that the small bore connection moves with the main pipe during start up, thermal transients and
vibration. Small bore connections shall not be braced from a local structure such as steel work, Decks etc. Any mass at the free
end of a cantilever shall be supported in both directions perpendicular to the axis of the small bore.
Type of Branch fittings for Flow Induced Vibration FIV prone lines shall be agreed with Consultant at early stage of Project.
For Small bore standout connections, the branch fitting & overall unsupported length shall be as short as feasible.
Provide Axial Stop support very close to Control valves. The recommended support configuration for Control valve is
Rest+Guide on one side & Rest+Guide+Axial Stop+Hold Down on the other side, subject to feasibility as per line geometry &
Stress analysis.
Provide adequate Hold down supports & Guides for FIV lines.
For High Delta P valves, provide spool on upstream & downstream piping to accommodate Anchor Support on one side & Guide
support on the other side.
For 2 Phase & Slug Flow lines, provide axial stops on main line at all changes of direction as per feasibility. It shall be ensured
that Guides & Axial stops in these lines are active for all Load cases. Also provide adequate Hold down supports (types FCG,
SG2 etc. as per Support Standard) for main line & braced support for Small bore stand-alone connections.
Minimize use of Trunion supports.
Any fastenings used shall be designed to be effective under vibration such as providing lock nuts etc.
Particular care shall be taken when adopting small bore supports that are welded to the connection and its main pipe, as these
welds provide additional sites for fatigue failure. Dressing of welds by grinding shall be recommended and discussed with
Construction.
Clamp type supports rely on bolted arrangements. Periodic inspection shall be recommended to ensure that no loosening occurs
during years of operation.
Appendix- 1(Work Process Steps and the Responsibility Matrix for AIV /FIV study)

6/24/2014 6:06 AM

Guidelines for Acoustic Induced Vibration (AIV), Flow Induced Vibration...

5 of 8

http://www.piping-engineering.com/acoustic-induced-vibration-aiv-flow-...

Related Posts:
Stress Analysis: Steps for Stress Analysis 1.0 Introduction to Stress Analysis Stress Analysis is a subject, which is ...
Purpose of Pipe Supports Purpose of Pipe Supports: 1. Introduction The Piping Profile in general can ...
Induced Stresses in Pipe- Hoop, Longitudinal and Radial Topic covered Introduction Circumferential or Hoop Stresses
Longitudinal Stresses Radial Stress Introduction to Induced Stresses: When ...
Selection of Pipe Supports: Parameters Considered The basic parameters considered during the selection of supports are ...
Cooling Tower: Heat Transfer Equipment in Process Industry 1.0 Introduction to Cooling Tower: Cooling Tower is the most
common equipment/ ...
Send

Leave a Reply

6/24/2014 6:06 AM

Guidelines for Acoustic Induced Vibration (AIV), Flow Induced Vibration...

6 of 8

http://www.piping-engineering.com/acoustic-induced-vibration-aiv-flow-...

Add a comment...

Facebook social plugin

Find us on Facebook

Piping-engineering
Like
486 people like Piping-engineering.

Facebook social plugin

Or reach me on aj@piping-engineering.com

Subscribe Updates. It's Free!


Your email:

6/24/2014 6:06 AM

Guidelines for Acoustic Induced Vibration (AIV), Flow Induced Vibration...

7 of 8

http://www.piping-engineering.com/acoustic-induced-vibration-aiv-flow-...

Google+
Recent Posts

Importance of Optical Fibre in Oil & Gas Sector


5:34 pm By Piping engineering
We all have heard about optical fibre and its wide applications in various industries. But many of us know very little about
its features and reason Read More

Solenoid Valve An Electromagnetic Part Of A Control Valve


1:16 pm By Piping engineering
Introduction to solenoid valve The solenoid valve is an electromagnetic part of a control valve. A solenoid valve is an
electromechanically operated valve used for controlling Read More

Plant Design And Management System PDMS An Overview


4:55 pm By Piping engineering
Table of contents: 1. Features Of PDMS 2. How PDMS is organized 3. Different Modules In PDMS Plant design
management system (PDMS) and its related application Read More

Crude Oil Processing on Offshore Facilities

6/24/2014 6:06 AM

Guidelines for Acoustic Induced Vibration (AIV), Flow Induced Vibration...

8 of 8

http://www.piping-engineering.com/acoustic-induced-vibration-aiv-flow-...

9:25 am By Piping engineering


Crude Oil Processing on Offshore Facilities Table of contents: 1. PURPOSE 2. SCOPE 3. DEFINITIONS AND
ABBREVIATIONS 3.1 Definitions 3.2 Abbreviations 4. DESCRIPTION 4.1 Overview Production Read More

Winterization: Protection Against Low Ambient Temperature


10:58 am By Piping engineering
Table of contents: 1. PURPOSE 2. SCOPE 3. DESCRIPTION 3.1 Application of Winterization 3.2 Winterization
Temperature 3.3 Methods 3.4 Application and extent of winterization 3.5 General Read More