Individual vents
Individual vents serve individual fixtures.
This vents only one fixture but may connect into an other vent that extend to the open air.
an individual vent should be at least one-half the size of the drain it vents (no less than 1 1/4", 32 mm)
Relief vents
Relief vents provide additional air to the drainage system where the primary vent is too far from the fixture.
an relief vent should be at least one-half the size of the drain it vents (no less than 1 1/4", 32 mm)
Circuit vents
Circuit vents are used with more than one fixtures. A circuit vent is installed before the last fixture extend up to open air or connects to an other vent
that extend to the outside
an circuit vent should be at least one-half the size of the drain it vents (no less than 1 1/4", 32 mm)
Branch vents
Branch vents are vents extending horizontally that connects multiple vents together.
Stack vents
A vent stack is used only for the purpose of venting.
Vents are normally sized by using the "Developed Length" (total linear footage of pipe making up the vent) method.
Maximum length of vent stacks and relief vents
Size of Soil
Waste Stack
(in)
Fixture Units
Connected
1 1/4
30
50
150
10
30
100
12
30
75
200
20
26
1 1/2
2
2 1/2
3
1 1/2
2 1/2
50
150
42
30
100
300
10
30
100
200
600
30
60
200
500
60
50
80
400
100
35
100
260
1000
200
30
90
250
900
500
70
180
700
200
35
80
350
1000
500
30
70
300
900
1100
20
50
200
700
20
Sponsored Links
Related Documents
Waste Water and Flow Capacity - In sewage piping and pumping systems the fluid flow rate must be kept within certain limits to avoid
operating problems
Drainage Fixture Unit Loads for Sanitary Piping - Maximum Drainage Fixture Unit - DFU - Loads for sanitary piping
Main Vents - Vents in draining systems protects traps against pressure differences that could cause them to siphon or blow out
Building Drains and Sewers - Number of Drainage Fixture Units connected to a building sewer
Copper Tubes DWV - Drain, Waste and Vent - Dimensions of copper tube ASTM 306 DWV - Drain Waste and Vent
Capacity of Sewer Pipes - Carrying capacity of sewer and wastewater pipes - gpm and liter per second
Tag Search
en: vents drain sewage
es: rejillas de drenaje de aguas cloacales
de: ffnungen abflieen Abwasser
Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your SketchUp model with the
Engineering ToolBox - SketchUp Extension/Plugin - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro . Add the
Engineering ToolBox extension to your SketchUp from the Sketchup Extension Warehouse!
Home
Acoustics
Air Psychrometrics
Basics
Combustion
Drawing Tools
Dynamics
Economics
Electrical
Environment
Fluid Mechanics
Gas and Compressed Air
HVAC Systems
Hydraulics and Pneumatics
Insulation
Material Properties
Mathematics
Mechanics
Miscellaneous
Physiology
Piping Systems
Process Control
Pumps
Standard Organizations
Statics
Steam and Condensate
Thermodynamics
Water Systems
Ads by Google
0.0
oC
oF
Convert!
Length
1.0
m
km
in
ft
yards
miles
nautical miles
Convert!
Volume
1.0
m3
liters
in3
ft3
us gal
Convert!
Velocity
1.0
m/s
km/h
ft/min
ft/s
mph
knots
Convert!
Pressure
1.0
Pa (N/m 2)
bar
mm H2O
kg/cm 2
psi
inches H2O
Convert!
Flow
1.0
m 3/s
m 3/h
US gpm
cfm
Convert!
Offshore
Share
mee ickets
- summarize meetings and keep track of tasks to be done - with tickets!
the Travlet
- tracking and sharing expenses between participants!
Sponsored Links
alibaba.com
98