Carnegie Mellon University, Engineering & Public Policy/ H. John Heinz III Professor
of Environmental Engineering, Carnegie Mellon University, Civil & Environmental
Engineering and Engineering & Public Policy
Abstract
Today, three billion people around the world have no access to clean drinking water and about 1.76
billion people live in areas already facing a high degree of water stress. This paper analyzes the costeffectiveness of a stand alone small-scale renewable energy powered sea water reverse-osmosis (SWRO)
system for developing countries. In this paper, we have introduced a new methodology; an energy
optimization model which simulates hourly power production from renewable energy sources. Using the
results of the model, we have computed hourly water production for a two stage SWRO system with a
capacity of 35m3/day. According to our results, specific energy consumption is about 2.33kWh/m3, which
is a lower value than that achieved in most of the previous designs. Using a booster pump, energy
recovery turbine and appropriate membrane, specific energy consumption could be decreased by about
70%. Furthermore, the energy recovery turbine could reduce water cost by about 41%. Still, power cost is
the major component of the total investment constituting about 80% of the total cost of the SWRO
system. Our results show that, wind powered system is the cheapest and a PV powered system, the most
expensive, with about 0.50$/m3 and 1.00$/m3, respectively. By international standards, for example, in
China, these values are considered economically feasible. Detailed simulations of RO system design,
energy options, power and water costs, and life cycle analysis are discussed.
_________________________________
Key Words:
1. Background
Today, about three billion people around the world have no acess to clean drinking water.
According to the World Water Council, by 2020, the world will be about 17 percent short of the
water to feed the world population. Moreover, about 1.76 billion people live in areas already
facing a high degree of water stress (Vrsmarty et. al, 2001). "Water stress" is on the top of the
worlds agenda at least as firmly as climate change (Vaknin, 2005). As a result, the need for
desalination is increasing, even in regions where water supply is adequate.
As part of the most affected arid areas of the world, Eritrea has been the victim of recurrent
droughts and water shortage. The problems of water supply vary from place to place and one of
the most severe problems exists in the coastal areas and islands (MLWE, 1995). Thus, the case
study will asses the use of renewable energy for sea water reverse osmosis for the coastal village
of Berasoel, located at the Southern Red Sea, Eritrea.
Sea water desalination is an energy-intensive process (Gaparini, 1985; Carta, et. al 2003). Most of the
available large scale desalination plants around the world are powered by fuel. Due to the concern of
global warming, and increasing fuel costs alternative energy sources has been proposed for desalination
purposes. For example, the International Atomic Energy Agency (IAEA) has proposed to use nuclear
power for large scale desalination plants (Carta et. al. 2003), and the use of renewable energy sources for
small scale desalination plants is emerging. Autonomous wind powered sea water reverse osmosis
potentials has been studied (Feron 1985; Marcos et.al. 2002) and pilot projects are in progress (Carta et.
al. 2003). However, the application of renewable energy for desalination has not yet reached sufficient
maturity to be applied widely. Moreover, most of the proposed designs are connected to the conventional
power grids (Sultan et. al. 2002, Carta et. al. 2003). Thus, the main objective of this research is to design
a cost-effective reverse osmosis system, which functions under optimal energy options. This paper
introduces a new methodology of an energy optimization model for the sea water reverse osmosis
(SWRO) system.
In the analysis, two major models are applied, namely Reverse Osmosis System Analysis
(ROSA)1, a sophisticated reverse osmosis (RO) design program that predicts the performance of
membranes in user specified systems, and HOMER2, an energy optimization model for hybrid as
well as stand alone power systems. Life cycle analyses are performed to examine the
performance of the system, determine water costs and undertake comparative analysis of
different options.
2. Situation Analysis
2.1 Water Demand: Recent studies conduced by the Swiss Federal Institute for Environmental
Science and Technology (2003) indicate that East African countries have renewable freshwater
resources below the calculated threshold of 1500 m3 per capita year. Eritrea is already in water
deficits. According to the recent studies, in the coastal parts of the country water demand is
116m3/household/year (Marie and Pedersen, 2001). Thus, for the Berasoel village of 108
households, we are assuming an average water demand of 35m3/day and 13,000m3/year.
2.2. Energy Supply: In Eritrea, there is a strong potential for wind-powered electricity
generation (Habtesion et. al. , 2001) and sunshine is abundant. The Southeast coast of Eritrea has
as much as 100 - 200 kilometres of 6 and 7 wind classes. At these sites, wind turbines may
operate at a 40% - 60% capacity factor (Habtetsion and Tsighe, 2002), which implies that the
wind potential ranges from excellent to exceptional (African Development Bank, 2004), and
could be potentially used for commercial and industrial purposes as well. The average annual
wind speed and solar radiation are about 6.8m/s and 6.8kWh/m2, respectively.
3. Modeling Sea Water Reverse Osmosis Design and Optimal Energy Options
3.1 Sea Water Reverse Osmosis Design Considerations
3.1.1 Model Description: ROSA 6.0.1 software is the latest version, used in the analysis in order
to determine the performance of a membrane and energy requirements for desalination. The use
of the model is influenced by the need to design a technically feasible RO system. We have
1
2
extended the application of the model in creating an operating window for a RO system that
could operate under intermittent power supply. This is done by running the model multiple times
under different water flow and pressures. The main inputs of the model include the amount of
feed water and its chemical characteristics, feed water flow rate, feed water and concentrate feed
pressures, temperature and pH. Then a configuration of the number of membranes, pressure
vessels, and type of membrane, and feed and booster pumps is determined. After performing
calculations, the model provides the amount of water produced and energy required. The energy
required to produce an intended amount of drinking water with acceptable water quality is then
determined by running the model multiple times. Booster pumps and an energy recovery turbine
are applied.
3.1.2 RO System Design and Energy Consumption: Using ROSA, we have performed several
RO design options capable of producing 35m3/day potable water. After performing several
design alternatives, our preferred design is a two stage design with three membrane elements in
each stage (figure 1). The reasons for choosing a two stage system is in order to increase water
productivity by applying a booster pump, and recover a significant amount of energy. The type
of the membrane used in the analysis is SW30HRLE-400. The membrane is designed to properly
function under intermittent energy supply (Dow, 2005).
Seawater Reverse Osmosis Desalination System for Beraso'ele Village, Southern Red Sea, Eritrea
Low pressure
pump
1st stage
membranes
Q5
Pr1
Feed water
from Red Sea
Pretreatment
Pw1
Post
Treatment
Q1
Q2 Pr2
High pressure
pump (Booster)
Pw2
2nd stage
membranes
Pr3
Q3
Pw3
Energy
Recovery
Turbine
Q7
Product
tank
Q6
Q4 Pr4
Product/
permeate
water
Figure 1: Schematic double stage RO system for the village of Berasoel, Southeastern Red Sea, Eritrea.
According to Darwish et. al (2002) the low pressure pump consumes the highest energy(Pw1),
and the rest constitutes about 20% of the LP pump. The power required for the systems LP
pump, at 10m3/h feed water flow rate, 45bar pressure, and 0.85 pump efficiency, is about
14.71kW. An additional 2.94kW will be needed for booster, feed water, chemical treatment and
other pumps, which is about 20% of the LP power requirement. Thus, the total power required
for the RO system design is about 17.64kW. Using ROSA software, we have obtained a similar
result, which is 17.23kW. The specific work done is about 3.92kWh/m3 potable water produced.
Without a booster pump, the system requires about 7.87kWh/ m3, and its water quality
deteriorates from 270 ppm to 800 ppm total dissolved solids. Moreover, if the booster pump is
not applied, water production in the second stage could decrease by about 33% per hour i.e. from
2.1 m3/hr to 1.4m3/hr. Thus, in terms of water production, water quality, and energy recovery, a
two stage RO design is a preferable. The system design has an average conversion factor of 55%
(relation between product water flow and feed water flow), producing about 4.4m3/hr of potable
water.
3.1.3 Performance Prediction: In designing the SWRO system that uses intermittent energy
sources, it is very important to design a RO system that could operate under broad operational
windows. The main thresholds of the operational window include the maximum feed pressure
(determined by the membrane mechanical resistance); maximum brine flow rate (should not be
exceeded to avoid membrane deterioration); minimum brine flow rate (should be maintained to
avoid precipitation and consequent membrane fouling); and maximum product concentration (if
the applied pressure is less than a determined value, the permeate concentration will be too high)
(Marcos et. al, 2002).
Using chemical characteristics of water of the study area (Thomson et. al., 2001), and varying
the values of variables of operational window thresholds, we have run the model several times.
According to the results of the analysis, at 250C, the maximum allowable pressure, maximum
brine flow rate, minimum feed flow rate, and minimum pressure of our design are about 50 bar,
16m3/h, 7m3/h, and 30 bar, respectively (figure 2a).
30
700
50 bar
25
45 bar
600
30 bar
500
400
35 bar
300
40 bar
45 bar
50 bar
200
40 bar
20
35bar
30 bar
15
10
100
0
6
10
11
12
13
3
(a)
14
15
16
17
10
11
12
13
14
15
16
17
(b)
Figure 2. (a) Water quality and feed water flow rate, (b) power thresholds of the SWRO system.
This design allows the production of potable water with an average water quality of about 500
ppm total dissolved solids or less, which is the World Health Organization (WHO)s water
quality acceptable standard. Likewise, in order to operate under this operational window, the
energy supply or pumping power should not be less than 7 kW and not exceed 26 kW (figure
2b). This means that, without interrupting the operation of the system, it can operate at as low as
7kW and as high as 26kW power supply, which is a wide operating window. This is one of the
aspects that could potentially make renewable energy resources for SWRO systems more
attractive.
The average conversion factor of the system, at 250C, is about 55%. Carta et. al.(2003)
indicated that for an increase of 10C, water production increases by about 4%. Thus, since the
climatic condition of the study area is very hot, with average monthly temperatures varying from
26.50C to 35.50C (Buskirk, 1998), it is expected that, most of the time of the year; the conversion
factor could reach as high as 70%.
3.1.4 Energy recovery: Energy recovery should be considered if brine exits the system at 300
psig or more, and if system recovery is less than 80 % (Amjad, Z. 1993). Since the brine
rejection pressure of our design is well above 300 psig, such as 760 psi (52.82 bar), the potential
for energy recovery is very high. For example, using an energy recovery turbine with an
efficiency of 0.85, at a concentrate pressure of 52.82 bar, and concentrate water flow of 5.6m3/hr,
about 6.98kW (equation 2) energy could be recovered. Thus, our design can potentially reduce
power consumption by half, from 15kW to about 9kW.
`
Pw
= Q n Pr n E t
(2)
Where, Et is turbine efficiency, Prn(kPa) is the feed pressure, and Qn(m3/s) is rates of the feed brine.
The type of energy recovery turbine under consideration is the pressure exchange (PX) turbine,
PX45s (Energy Recovery Inc. Data Sheet, 2005). Using this energy recovery device, net energy
consumption could be reduced from 17.23kW to 10.25kW, and specific energy consumption
from 3.92kWh/m3 to 2.33kWh/m3. This is about a 40% energy recovery, and it is a substantial
energy recovery opportunity for a small scale sea water reverse osmosis system. Therefore, using
a boosted pump and energy recovery turbine, energy consumption has decreased from about
7.87kWh/ m3 to about 2.33kWh/m3. Darwish (2002) and a RO system in a Caribbean (Curacao)
islands have reported a specific energy consumption of 4.52kWh/m3, and 3.15kWh/m3,
respectively, for 5700 m3/day desalination water capacity. Compared with these results, our
design results are low, though compatible.
Thus, depending on the feed flow rate and pressure exerted, our operating window of the system
can potentially recover anywhere between 4kW to 12kW. The RO system is expected to operate
under a semi-instantaneous base load of 17kW. Thus, assuming a feed pressure of 45 bar,
boosting pressure of 10 bar and feed water flow rate of 10 m3/hr, the system can recover about 4
kW to 7 kW per hour (figure 3). Moreover, increasing the feed water flow rate at low pressure
could substantially increase energy recovery and water production. In this regard, within the
operational window of the system, any other points of operation could be selected as an initial
point of operation.
Proceedings of the International Conference on Renewable Energy for Developing Countries-2006
Energy recovery(kW)
Energy consumption/recovery(kW)
20
15
10
0
6
10
11
12
13
14
15
16
17
Feed water(m3/hr)
In order to solve the challenge, we have designed the SWRO system to operate anywhere
between 7kW and 27kW, which are the allowed operating power thresholds. Any power below
and above about 7kW and 27kW, could ultimately be considered as excess power. Thus, we are
trying to optimize the regular SWRO power load under an irregular power supply, which makes
the analysis complex, especially when wind energy is considered. Based on the base load power
requirement, different energy models are simulated with different based load configurations,
with and without energy storage devices. An energy dispatch strategy is designed to fulfill the
base load of the RO system depending on the type of energy option selected.
3.2.3 Wind Power
3.2.3.1. Implications of Wind Speed Variations: The average wind speed of the study area is 6.8
m/s (GoE, 2004). Wind speed distributions can typically be described in terms of the Weibull
distribution (Feron, 1985). According to Rosen (1998), the shape parameter for the Southern Red
Sea area, particularly Port Assab, is 2.4. The standard Weibull shape parameter is 2.5. Using the
Danish Industry Wind Association power calculator, at 250C, 10m above sea level, 101.21 kPa
atmospheric pressure, 1.22 kg/m3 air density and 2.4 shape parameter, the scale parameter is
7.67. Thus, using equation 3, the probability of the wind speed distribution is computed.
k v
fv ( v ) =
c c
k 1
( )
exp v
(3)
V 1 +
However, wind speeds throughout the seasons are irregular, and the average wind speed has high
seasonal variations. According to the U.S. Navy Climatic Study of the Red Sea report conducted
in 1982 (Rosan, 1998), for 7 months (October through April), mean wind speeds are between 6
m/s and 10 m/s, and the remaining months (May through September), mean wind speeds are
between 3 m/s and 5 m/s. Assuming an average wind speed of 8 m/s for season 1(October
through April ) and 4 m/s for season 2 (May through September), the scale parameters are 9 and
4.5, respectively. The density and cumulative Weibull distributions of the two seasons are shown
in figure 5. A very high wind speed in one season and a very low wind speed in the other season
makes the modeling process more complex. That is, the irregularity of seasonal wind speed
makes the system more complex to optimize without expecting very high excess electricity
during the high wind speed season, and employing energy storage systems during the low wind
speed season. Most studies indicate that to overcome power shortages during the low wind speed
seasons a large number of wind turbines should be installed (Cavalllo,1997 and De Carlos and
Keth, 2002, Denhom et.al, 2005). This is one of the issues that we need to address in this
analysis.
3.2.3.2. Model Input: In this analysis, we assume that the RO system will be powered by a stand
alone wind turbine. In this model, a 17kW base load is considered in order to produce potable
water at about 2.33 kWh/m3. This approach allows capturing all wind energy outputs, produced
whenever the wind is blowing. Taking in to consideration the above mentioned seasonal wind
speed and energy variations, we have considered monthly average wind speeds, with an annual
average wind speed of 6.8 m/s. The monthly average wind speeds are then simulated to hourly
wind speeds for 8750 hours of a year. Using a FL3 30kW wind turbine the result of the
simulation are shown in figure 6.
Seasonal variation of wind speed
0.25
Season 1(Oct. to April)
Season 2 (May to September)
Total
Probability
0.20
0.15
0.10
0.05
0.00
0
10
12
14
16
18
20
According to the model, the effective annual number of hours is more than 4000 hours. Thus, the
wind turbine seems to be a good candidate for the analysis. However, in doing so, excess
electricity is expected, especially during the high wind speed season. Thus, using FL 30 wind
turbine with a lifetime of 20 years (Manwell 2002), capital cost of $130,000, and operation and
Fuhrlnder(FL) 30kW is a type of 30kW wind turbine developed by Fuhrlnder AG. http://www.fuhrlaender.de/start.php
maintenance costs of $3900 (2.5% of capital cost) (DuPont, 2004) and replacement cost (85% of
the capital cost), an analysis has been conducted and its performance determined.
3.2.3.3. Results of the Analysis: According to the optimization results, the least cost and feasible
wind energy option consist of one FL 30kW wind turbine, 10 batteries, and 10 converters. The
cost of this option is about $0.17/kWh with a capacity shortage of about 51%. This means that
our RO system will be functional at full capacity for about 4000 hours of the year, producing
about 30,000m3/year. Since most of the high wind speeds are during the day, the system can
operate for more than 8 to 12 hours per day for the whole year totaling 4000 hours of a year. In
order to deal with water production increase during high temperature and wind speed seasons,
there might be a need to build a water storage tank in order to store water to be used during the
low-wind-speed season of the year.
It should be noted that the use of a battery as an energy storage device is not solely meant to
increase energy production. The primary objective is to keep the power supply at a semiinstantaneous condition (fig. 7) so that the RO system could produce water continuously. When
wind power is starting to decrease, electricity is dispatched accordingly to meet the demand. This
could also potentially minimize the deterioration of membranes. According to the results of the
model, the lowest wind speeds occur from mid night up to early in the morning. Thus, there is a
possibility of putting off the RO system or adjusting it to function with battery power during this
time interval. Annual wind power output, base load, and water production scenarios are shown in
figure 8.
RO Baseload, Wind Power and Water Production
40
35
30
25
20
15
10
5
0
-5
50
100
150
200
250
300
350
400
-10
-15
Time(hr)
Figure 7: Base load, wind power production, battery power dispatched, and water production for
the first two weeks of the month of January.
40
35
30
25
20
15
10
5
0
0
1000
2000
3000
4000
5000
6000
7000
8000
-5
Time for one year (hr)
Figure 8: Annual wind power, base load, and water production scenarios.
10
time the PV power is above or equal to the base load. Since the RO system can operate at up to
27 kW, all the electricity could be used producing as high as 8 m3/hr. Under this scenario, on
average water production is about 5 m3/hr. Without battery storage, annual water production is
about 11,600 m3 and with battery storage, about 14, 000 m3. Thus, PV power with battery
storage increases water production by about 20%. Figure 10 shows the annual load, power and
water produced. From this analysis, it can be concluded that the PV-battery configuration is an
appropriate configuration option, enough to achieve daily water needs without substantially
investing in a big water storage tank.
Baseload of RO, PV Power, Battey Power Storage and Dispatch and Water Production
35
30
25
20
15
10
5
0
0
10
20
30
40
50
60
70
80
90
100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340
-5
-10
-15
Time (hr)
Figure 9: The first two weeks of the month of Januarys simulated RO base load, PV
power produced, battery power dispatched/stored in kW, and water produced (m3/hr).
RO Baseload kW
RO Base load, PV Power Produced and Water Produced for one year
PV Power kW
Water Produced
40
35
30
25
20
15
10
5
0
0
1000
2000
3000
4000
5000
6000
7000
8000
Time(hr)
11
hours. In Eritrea, the cost of electricity produced by the gensets is at least twice as expensive as
grid electricity (Habtesion and Tsighe, 2005). This is mainly due to the high diesel transporting
cost to remote areas, high maintenance costs and high fuel consumption. Despite such high costs,
users tend to give high value to the power generated by gensets as it is flexible to meet the
energy needs of both domestic and income generating activities.
3.2.5.2 Results of the Analysis: According to the results of the analysis, a 25 kW diesel
generator is enough to meet the intended water demand, operating for about 8 hours per day. The
cheapest electricity cost and feasible option of diesel generator is about 0.29 $/kWh.
3.2.6 Integrated Power System
This option simulates the combination of the three options such as wind, PV and diesel energy
sources with battery as energy storage. In this scenario, the challenge is the assumptions of base
load configurations. In the case of stand alone power systems, it is possible to configure the base
load according the behavior of energy sources. In an integrated case, we will assume that the
base load will be the same as the wind energy configuration 24 hours per day and 8750 hours per
year. Then, based on the simulation results, in addition to least cost options, we will determine
the most feasible options.
In an integrated approach, whenever wind energy is available it is the cheapest option. Under
this scenario, the cost of electricity of the feasible options ranges from 0.17 $/kWh to 0.22
$/kWh, for stand alone wind turbine with battery, and wind turbine and PV with diesel
(W_PV_D), respectively. A 5 kW PV, 30 kW wind turbine, and 5 kW battery are one of the least
cost ($0.190/kWh) choices. However, it seems that whenever wind speed is very high, PV
energy is also very high. Thus, there is no point to incorporate PV power in our system. Wind
energy with a battery is the cheapest option ($0.170/kWh), and it is a feasible choice with the
lowest capacity shortage of about 55%. Thus, for SWRO system an integrated system might not
be feasible option.
4. Discussion
4.1. Energy Options: Based on the renewable energy potential of the study area, both wind and
PV energy resources are feasible. With respect to power cost, the optimization model doesnt
incorporate price uncertainty. All costs are simulated based on the net present value. According
to the optimization model, at about a 6% interest rate, the PV powered RO system is more
expensive than the wind powered RO system, with the costs about 0.39 $/kWh and 0.17 $/kWh,
respectively (table 1). However, the results of our sensitivity analysis shows that PV could be
competitive with wind energy as the interest rate increases. As a result of changes in interest
rates, production, and other factors, energy prices are volatile4, especially for diesel. Thus,
assuming about 25% error, we have calculated the maximum and minimum power costs (figure
11). According to the results, the minimum and maximum wind power costs are about 0.13
$/kWh and 0.22 $/kWh, respectively. Likewise, for PV power, the minimum and maximum
costs are about 0.30 $/kWh and 0.50 $/kWh, respectively. In either case, wind power is cheaper
4
The research will be further extended (not discussed in this paper) to incorporate energy prices volatility using stochastic
process.
12
than PV power. In terms of reliability, for this particular area of study, it seems that PV is more
reliable than wind. This is due to the fact that the duration of the availability of sunshine is more
predictable than the wind speed. As a result, it is easier to schedule the operation of PV powered
RO systems than a wind powered system.
4.2 Water cost: In the last 20 years, the water cost from SWRO has dramatically decreased from
about $2.8/m3 to $1.5/m3. This has been attributed to the use of energy recovery devices, and
efficient membranes that allow rejection of salt at low pressure (Meyer-Steele and Gottberg,
2005). Water costs are analyzed based on the overall life cycle of the RO system, which includes
the capital costs of the initial membrane, pressure vessel, pumps, energy recovery turbine, and
operational and maintenance for membrane replacement and electricity costs. The power costs
(table 1) are the results of an optimization model for selected energy options. Assuming the life
time of the RO system is 10 years, at 10% interest rate, water costs are computed (table 1).
According to the results of the analysis, energy expenses per cubic meter water produced range
from 0.520 $/m3 for wind powered, and 1.06 $/m3 for the PV powered RO system. PV powered
water cost is more expensive than wind powered by about a factor of two. Recent studies
indicated that today a cost of $1/m3 for seawater desalination would be feasible (Zhou and Tol ,
2005). With an estimated 25% water cost error, water costs for each option are shown in figure
12.
Table 1: Summary of power and water costs for different energy options
1
Energy Options*
W_B
W_PV_B
W_D
W_D_B
W_PV_D_B
W_PV_D
PV_B
PV
0.170
0.190
0.197
0.200
0.217
0.222
0.286
0.394
0.402
Water cost($/m3)**
0.522
0.569
0.585
0.592
0.631
0.643
0.791
1.042
1.061
(1). W_B= Wind and battery; (2). W_PV_B= Wind, Photovoltaic, and Battery; (3). W_D= Wind and diesel; (4) W_D_B= Wind,
diesel, and battery; (5). W_PV_D_B= Wind, Photovoltaic, Diesel, and Battery; (6). W_PV_D= Wind, Photovoltaic, and Diesel; (7).
D= Diesel Only;
(8). PV_B= Photovoltaic and Battery; and (9). PV= Photovoltaic.
0.55
1.50
0.50
0.45
1.25
Water costs($/m )
0.35
Power cost($/kWh)
0.40
0.30
0.25
0.20
1.00
0.75
0.50
0.15
0.10
0.25
0.05
0.00
0.00
Energy Options
10
10
Energy Options
(Note: the number of energy options corresponds with the types of energy options shown in table 2).
13
According to the results, power cost constitutes the highest proportion (fig. 13). Regardless of
the type of energy option chosen, the fraction of energy expenses per cubic water produced is
about 80% of the total expenses. The proportion of expense per cubic water produced for other
expenses constitutes less than 20%, which includes the initial membrane and pressure vessel
(3%), the capital cost of the energy recovery turbine, pumps and miscellaneous (8%), and the
membrane replacement cost (3%).
4.3 Water productivity: According to the model, wind powered (option 1) and PV powered
(Option 2) RO systems could produce about 30,000 m3 and 15,000 m3 per year, respectively. PV
produces about the exact demand at high price and wind produces more than double of the
required amount at the cheapest price. Wind powered water production for the months of
November through March is about 4000 m3/month and for the months of April through October,
about 1600m3/month (figure 14). The PV powered RO system produces a constant amount of
water, 1,200 m3/month. Based on the potential of water productivity and water cost, the wind
powered RO system is indicated to be the best option.
4.4 Implications of battery storage: We have tried to compare the implications of energy
storage in wind and PV powered systems. For wind and PV systems with energy storage, the
average water production increases by about 11% and 6%, respectively (figure 15). This implies
that, using our model, the use of battery storage in a RO system is more pronounced or important
for the PV than the wind powered RO system. Moreover, in addition to increasing water
production at a minimum incremental cost of about 6% for battery in wind and 2% for battery in
PV, it helps to decrease the intermittency of the electricity flow.
4.5 Implication of Energy Recovery: An attempt has also been made to compare the impact of
energy cost with and without the energy recovery system (figure 16). The results show that
using a pressure exchange (PX) 45s energy recovery turbine, the energy expenses for the wind
powered option for example could be reduced by about 41% from 0.67 $/m3 to 0.40 $/m3. The
capital cost of a PX 45s energy recovery turbine, which is about $12,000, could be paid back
within a year.
$1.1
4500
Energy expenses with ER ($/m3)
Capital cost(turbine,pumps,misl.)/m3
Memb Repl
Init Memb + PV Capital
$0.9
$0.7
$0.6
$0.5
$0.4
$0.3
PV Powered
3500
Wind Powered
3000
2500
2000
1500
1000
$0.2
500
$0.1
Ju
ly
O
ct
ob
er
ov
em
be
r
D
ec
em
eb
er
N
Months
Se
pt
em
be
r
Energy options
PV
Au
gu
st
PV_B
ay
Ju
ne
W_PV_D
W_PV_D_B
ch
W_D_B
Ap
ril
W_D
M
ar
W_PV_B
Fe
b
W_B
ra
ua
ry
$0.0
Ja
nu
ar
$ per m3 of water
$0.8
4000
Water Production(m3/month)
$1.0
14
Energy Expense with and without energy recovery(ER) the system under different energy options
14%
PV Powered
$1.6
Wind Powered
$1.4
$1.3
10%
$1.2
$1.1
8%
$ per m 3 of water
$1.5
12%
6%
4%
$1.0
$0.9
$0.8
$0.7
$0.6
$0.5
$0.4
2%
$0.3
$0.2
$0.1
r
eb
e
be
r
$0.0
W_B
De
ce
m
No
ve
m
be
r
ct
ob
er
O
pt
em
Se
Ju
ly
Months
Au
gu
st
ne
Ju
ay
M
ry
ril
Ap
ry
nu
a
au
a
Fe
br
Ja
ar
ch
0%
W_PV_B
W_D
W_D_B
W_PV_D_B
W_PV_D
PV_B
PV
Energy options
5. Conclusion
This paper has analyzed the performance of a renewable energy powered small scale sea water
reverse osmosis system particularly in terms of water productivity and energy cost. The RO
system has been designed with a wide operating system capable of operating under intermittent
energy supply. Results of our analysis show that the contribution of the booster pump and energy
recovery are not negligible in increasing water productivity and decreasing energy consumption
per cubic meter of water produced. Our results show that using the available technologies, it is
possible now to produce water at about 2.33 kWh/m3, which for a long time seemed unattainable.
Using a booster pump and energy recovery turbine, energy consumption can be decreased from
about 7.87 kWh/m3 to about 2.33 kWh/m3. The results indicate that wind powered water
production (0.50 $/m3) seems economically feasible. According to Zhou and Tol (2004), in
China, 1.0 $/m3 desalinated water is considered as economically feasible. This implies that even
a PV powered system could be competitive, and most of the world could benefit. Generally, in
Eritrea water production and tariff costs are about 0.30/m3 and $0.43/ m3, respectively. This
implies that wind powered system might be competitive.
Our energy optimization model for reverse osmosis desalination system is the first step toward
facilitating its widely used application. Moreover the energy optimization model, which has not
been used before for such purpose, provides a useful and easy model, particularly in simulating
hourly renewable energy production and consequently synchronizing with the energy load in
order to operate under the wide operating system of the RO plant. However, in order to
determine the robustness of the methodology, we should point out that the model needs to be
tested. We recommend that since the availability of energy recovery systems capable of
operating under wide operating system are limited, for higher water productivity and continuous
energy recovery, it is important to operate above 10m3/hr feed water at low pressures between 30
to 45 bars. The lower the pressure the lower the energy required to produce water.
15
6. Further Research
In this paper, energy options are selected primarily based on the Net Present Values (NPVs). The
research will be further extended to look at the impact of optimal investment options under
uncertainties in energy prices under clean development mechanism (CDM) of the United Nations
Framework Convention on Climate Change (UNFCCC). We believe that stochastic process as a
result of energy price and demand volatility could give a valuable incentive in determining
energy options under CDM beyond the SWRO system.
References:
African Development Bank, 2004. Strategic Study of Wind Energy Deployment in Africa,
Hlimax nergie inc. March, 2004. http://www.afdb.org
Buskirk, R, Garbesi, K & Karen Rosen. South Red Sea Wind and Solar Radiation Maps.
http://www.punchdown.org/rvb
Carta,J. Gonzalez,J and Subiela, V.(2003). Operational Analysis of an innovative wind powered
reverse osmosis system installed in the Canary Islands. Solar Energy 75(2003) 153-168.
Chen JZ, Li GH ,2005. Marine Reverse Osmosis Desalination Plant - A case study. APR 20
2005
Darwish, M, Asfour, N and Al-Najem(2002). Energy Consumption in equivalent work by
different desalinating methods: case study for Kuwait. Desalination 152 (2002) 83-92.
Danish Industry Wind Association (2005). http://www.windpower.org
DeCarolis J; Keith, D.W. Is the Answer to Climate Change Blowing in the Wind ? Proceedings
of the first International Doctoral Consortium on Technology, Policy, and Management, Delft
University, Delft, 2002.
DOW (2005). FILMTEC Membrane, System Design: Membrane System Design Guidelines,
Form No. 609-02054-604. (2005).
DOW (2005). ROSA 6.0.1 Software. http://www.dow.com (2005).
DuPont, H (2004). Wind Diesel Workshop, Lorax Energy Systems LLC. Block Island, RI.
September 29, 2004. http://www.eere.energy.gov/windandhydro/windpoweringamerica/pdfs/
Energy Recovery Inc. Data Sheet (2005), Performance Curves PX-45s Pressure Exchanger.
http://www.energy-recovery.com/pdf (2005)
Feron, P. 1985. The Use of Wind power in Autonomous Reverse Osmosis sea Water
Desalination. Wind Energy Group, the Netherlands. Wind Engineering, Vol. 9. No.3. 1985
16
17
Zhou, Y. and Tol, R.(2005). Evaluating the costs of desalination and water transport. Water
Resources Research. VOL. 41. March 2005.
Zhou, Y. and Tol, R.(2004). Implications of desalination for water resources in China--an
economic perspective. Desalination 164(2004) 225-240. November, 2004.
18