(vi) Each flow monitoring device shall flare monitoring plan shall include, at a and record total volume and total sulfur
achieve a temporal sampling resolution minimum, the following: concentration of gases combusted in the
of at least one flow rate measurement (i) A facility plot plan showing the flare.
per minute, meet the requirements location of each flare in relation to the (xii) A complete description of the
expressed in the definition of hourly general plant layout; method and equations used to calculate
average in 40 CFR 52.1392(c)(12), and (ii) Information regarding pilot and the amount of total sulfur, including all
be installed in a manner and at a purge gas for each flare; what is used for conversion factors. The total sulfur
location that will allow for accurate pilot and purge gas and how the concentrations will be used in the
measurements of the total volume of the concentration and volumetric flow rate methods referenced in 40 CFR
gas stream going to each flare. monitors are analyzing the pilot and 52.1392(h)(4) to determine compliance
(3) Flare concentration monitoring: purge gases. with the three-hour emission limit.
(i) Within 180 days after receiving (iii) Drawing(s) with dimensions, (xiii) A schedule for the installation
EPA approval of the flare monitoring preferably to scale, and an as built and operation of each flare monitoring
plan required by 40 CFR 52.1392(h)(5), process flow diagram of the flare(s) system consistent with the deadline in
each facility named in 40 CFR identifying major components, such as 40 CFR 52.1392(h)(2).
52.1392(a) shall install and calibrate, flare header, flare stack, flare tip(s) or (xiv) A complete description of the
and thereafter calibrate, maintain and burner(s), purge gas system, pilot gas methods to be used to estimate flare
operate, a continuous total sulfur system, ignition system, assist system, emissions when either the flow
concentration monitoring system water seal, knockout drum and monitoring device or total sulfur
capable of measuring the total sulfur molecular seal. analyzer are not working or the
concentration of the gas stream to each (iv) A representative flow diagram operating range of the monitor or
flare. Continuous monitoring shall occur showing the interconnections of the analyzer is exceeded.
at a location(s) that is (are) flare system(s) with vapor recovery (xv) A complete description of the
representative of the gas combusted in system(s), process units and other methods to be used for calculating, and
the flare and be capable of measuring equipment as applicable. hourly and three-hour SO2 emission
the expected range of total sulfur in the (v) A complete description of the from flares.
gas stream to the flare. The assist system process control, flame (6) Thirty days prior to installing the
concentration monitoring system may detection system and pilot ignition continuous monitors required by 40
require one or more concentration system. CFR 52.1392(h)(2) and (3), each facility
(vi) A complete description of the gas named in 40 CFR 52.1392(a) shall
monitoring devices or concentration
flaring process for an integrated gas submit for EPA review a quality
measurements at one or more locations
flaring system that describes the method assurance/quality control (QA/QC) plan
if one monitor cannot measure the total
of operation of the flares. for each monitor being installed.
sulfur concentration to each flare.
(vii) A complete description of the
(ii) The total sulfur analyzer(s) shall vapor recovery system(s) which have [FR Doc. 06–6096 Filed 7–11–06; 8:45 am]
achieve a temporal sampling resolution interconnection to a flare, such as BILLING CODE 6560–50–P
of at least one concentration compressor description(s), design
measurement per fifteen minutes, meet capacities of each compressor and the
the requirements expressed in the vapor recovery system, and the method
definition of ‘‘hourly average’’ in 40 currently used to determine and record FEDERAL COMMUNICATIONS
CFR 52.1392(c)(12), be installed, the amount of vapors recovered. COMMISSION
certified (on a concentration basis), and (viii) Drawing(s) with dimensions,
operated in accordance with 40 CFR 47 CFR Part 73
preferably to scale, showing the
part 60, Appendix B, Performance following information for proposed flare
Specification 5, and be subject to and [DA 06–1308; MB Docket No. 04–318; RM–
gas stream monitoring system: 11040]
meet the quality assurance and quality (A) Sampling locations; and
control requirements (on a (B) Flow monitoring device and total
concentration basis) of 40 CFR part 60, Radio Broadcasting Services; Culebra
sulfur analyzer locations and the and Vieques, Puerto Rico
Appendix F. methods used to determine the
(iii) Each affected facility named in 40 locations. AGENCY: Federal Communications
CFR 52.1392(a) shall notify the Air (ix) A detailed description of Commission.
Program Contact at EPA’s Montana manufacturer’s specifications, including ACTION: Proposed rule; denial.
Operations Office, Federal Building, 10 but not limited to, make, model, type,
West 15th Street, Suite 3200, Helena, range, precision, accuracy, calibration, SUMMARY: We deny the petition for rule
MT 59626, in writing of each Relative maintenance, a quality assurance making filed by Western New Life, Inc.,
Accuracy Test Audit a minimum of procedure and any other relevant proposing the substitution of Channel
twenty-five (25) working days prior to specifications and information 291A for Channel 254A at Culebra,
the actual testing. referenced in 40 CFR 52.1392(h)(2) and Puerto Rico. To accommodate the
(4) Calculation of SO2 emissions from (3) for all existing and proposed flow substitution, Petitioner also proposed
flares. Methods for calculating hourly monitoring devices and total sulfur the deletion of vacant Channel 291B at
and three hour SO2 emissions from analyzers. Vieques, Puerto Rico. We find that
flares shall be submitted with the flare (x) A complete description of the neither the deletion of Channel 291B,
monitoring plan discussed in 40 CFR proposed data recording, collection and nor the alternative downgrade and
wwhite on PROD1PC61 with PROPOSALS

52.1392(h)(5). management and any other relevant substitution of Channel 254A for
(5) By [DATE 180 DAYS AFTER specifications and information Channel 291B at Vieques, is in the
PUBLICATION OF THE FINAL RULE referenced in 40 CFR 52.1392(h)(2) and public interest. Specifically, expressions
IN THE Federal Register], each facility (3) for each flare monitoring system. of interest have been filed to retain the
named in 40 CFR 52.1392(a) shall (xi) A complete description of the Vieques vacant channel as a Class B
submit a flare monitoring plan. Each proposed method to determine, monitor allotment.

VerDate Aug<31>2005 18:09 Jul 11, 2006 Jkt 208001 PO 00000 Frm 00044 Fmt 4702 Sfmt 4702 E:\FR\FM\12JYP1.SGM 12JYP1
Federal Register / Vol. 71, No. 133 / Wednesday, July 12, 2006 / Proposed Rules 39279

FOR FURTHER INFORMATION CONTACT: Information Center (Room CY–A257), required to submit a copy of this Report
Sharon P. McDonald, Media Bureau, 445 12th Street, SW., Washington, DC. and Order to GAO, pursuant to the
(202) 418–2180. The complete text of this decision may Congressional Review Act, see 5 U.S.C.
also be purchased from the 801(a)(1)(A) because the proposed rule
SUPPLEMENTARY INFORMATION: This is a Commission’s copy contractor, Best was denied.)
synopsis of the Commission’s Report Copy and Printing, Inc., Portals II, 445
and Order, MB Docket No. 04–318, Federal Communications Commission.
12th Street, SW., Room CY–B402,
adopted June 21, 2006, and released Washington, DC 20554, telephone 1– John A. Karousos,
June 23, 2006. The full text of this 800–378–3160 or http:// Assistant Chief, Audio Division, Media
Commission decision is available for www.BCPIWEB.com. This document is Bureau.
inspection and copying during normal not subject to the Congressional Review [FR Doc. E6–10729 Filed 7–11–06; 8:45 am]
business hours in the FCC Reference Act. (The Commission, is, therefore, not BILLING CODE 6712–01–P
wwhite on PROD1PC61 with PROPOSALS

VerDate Aug<31>2005 18:09 Jul 11, 2006 Jkt 208001 PO 00000 Frm 00045 Fmt 4702 Sfmt 4702 E:\FR\FM\12JYP1.SGM 12JYP1

Вам также может понравиться