H3C S12500 High Availability and High Reliability Technology White Paper

H3C S12500 High Availability and High


Reliability Technology White Paper
Key words: HA, high reliability
Abstract: As a mandatory feature of a carrier-class device, high availability (HA) enables high reliability. If
any fault occurs, HA feature helps rapidly and properly restore system running, thus lessening
mean time to repair (MTTR). Network HA refers to maximizing system running time on the basis of
limited cost, thus minimizing the losses resulting from service interruption caused by a fault.
Acronyms:
Acronym

Full Spelling

BFD

Bidirectional Forwarding Detection

DLDP

Device Link Detection Protocol

FIB

Forwarding Information Base

FRR

Fast ReRoute

GR

Graceful Restart

HA

High Availability

LACP

Link Aggregation Control Protocol

MPLS

Multiprotocol Label Switching

MTBF

Mean Time Between Failures

MTTR

Mean Time To Repair

NSF

None Stop Forwarding

OAA

Open Application Architecture

OAM

Operations Administration and Maintenance

OAP

Open Application Platform

RPR

Resilient Packet Ring

RRPP

Rapid Ring Protection Protocol

VPN

Virtual Private Network

VRRP

Virtual Router Redundancy Protocol

Hangzhou H3C Technologies Co., Ltd.

Page 1 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

Table of Contents
Overview 3
Background 3
Benefits 3
Implementation of Reliability Technology of System Architecture 4
Introduction to Four Boards and Four Planes in One Device 4
Reliability of Control Plane 5
Advantages of Dual MPUs 5
Running Mechanism of Dual MPUs 5
Introduction to Hot Backup 5
Reliability of Forwarding Plane 6
Reliability of Detection Plane 7
Reliability of Support Plane 7
Reliability Technology of Power Supply 7
Reliability Technology of Fan 8
Hot Swapping Technology 9
HA of Services 9
Introduction to NSF Technology 9
High Reliability Technology of Link 11
Link Aggregation Technology 11
RRPP Technology 11
Smart Link Technology 12
DLDP Technology 13
High Reliability Technology of Network 15
VRRP 15
Equivalent Route 17
BFD 17
IP FRR 18
MPLS TE FRR 19
HA of Software Maintenance (Software Hot Patch on Line) 20

Hangzhou H3C Technologies Co., Ltd.

Page 2 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

Overview
Background
As a mandatory feature of a carrier-class device, HA feature helps rapidly and properly restore
system running in the case of a fault, thus lessening MTTR and increasing mean time between
failures (MTBF).
As the amount of data traffic increases as well as the requirement for QoS, HA increasingly becomes
one of the most important features of a high-performance network. Network HA refers to maximizing
system running time on the basis of limited cost, thus minimizing the losses resulting from service
interruption caused by a fault. A network featuring HA should reduce faults of hardware and software
and back up important resources. Once detecting that a fault may occur, the system can rapidly
transfer the tasks to be affected to the backup resources to continue service provisioning.

Benefits
Built upon a non-blocking Clos switching architecture with higher performance and better scalability,
H3Cs new-generation S12500 series routing switches are free from a single-point failure in
architecture, hardware, software, and protocol, reaching carrier-class reliability requirement, 99.999%.
The S12500 series switches support diversified HA and high reliability features:

System architecture reliability


z

Four boards and four planes in one device: Four boards refer to the main processing unit (MPU),
switching fabric module, line processing unit (LPU), and open application architecture (OAA)
board. Four planes refer to the support plane, detection plane, control plane, and forwarding
plane. The control plane is physically separate from the forwarding plane.

Reliability of control plane: The device supports dual MPUs for redundancy and rapid
active/standby switchover.

Reliability of forwarding plane: The advanced forwarding architecture of Clos non-blocking switch
fabric supports multiple independent switching network boards and N+M redundant backup of
switching capacity.

Reliability of detection plane: The device supports redundant backup of dual detection planes
which are separate from each other. The detection plane rapidly detects various network
protocols and switches over services.

Reliability of support plane: The device supports redundant backup of power supply, fan, storage
device, and clock. It also supports detection control of the power supply system and fan system.
It reports an alarm if any failure is detected. Furthermore, all boards support hot swapping.

HA of services
z

Non-stop forwarding technology: NSF, GR

Link high-reliability technology: DLDP, Smart Link, RRPP, link aggregation

Network high-reliability technology: VRRP, ECMP, dynamic routing fast convergence, BFD for
VRRP/BGP/IS-IS/OSPF/RSVP, TE FRR/IP FRR

Hangzhou H3C Technologies Co., Ltd.

Page 3 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

HA of software maintenance
z

Supporting hot patch

Supporting online upgrade

Implementation of Reliability Technology of System


Architecture
Introduction to Four Boards and Four Planes in One Device
Figure 1 System architecture

As shown in Figure 1, an S12500 switch is built upon a carrier-class high-reliability architecture with
four boards and four planes on it.
z

The control plane consists of the CPU system of the MPU, the CPU system of LPUs, and
management channels on the backplane. As the control core part of the switch, the control plane
carries out protocol operation, routing table maintenance, device management, and operation,
administration & maintenance.

Consisting of switching units, forwarding engines, and data channels on the backplane, the
forwarding plane implements service processing and data forwarding, including L2 forwarding in
Ethernet, ACL/QoS, IP forwarding, MPLS VPN and multicast.

Consisting of the CPU of MPUs, dedicated OAM detection engine and OAM channels, the
detection plane implements fast detection of various network protocols and fast service

Hangzhou H3C Technologies Co., Ltd.

Page 4 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

switchover, for example, RRPP, BFD for BGP/IS-IS/OSPF/RSVP/VPLS PW/VRRP. It can


achieve 50 ms service switchover.
z

Consisting of the control system and the control channel of each module, the support plane
implements such functions as detection and control of power supply system and fan system, and
reporting alarms.

The four planes are independent from each other without affecting each other. The system reliability
reaches 99.999%.

Reliability of Control Plane


The S12500 series switches support active and standby MPUs, which is an important embodiment of
high reliability technologies. As the core of the control plane, the active MPU communicates with the
external for service implementation and implements normal functions of each module, while the
standby MPU is the backup of the active MPU without communication with the external for service
implementation. When the active MPU fails, the switch automatically implements active/standby
switchover. Then, the standby MPU takes over tasks of the active MPU to guarantee normal service
running.

Advantages of Dual MPUs


Compared with a single MPU, dual MPUs show much better convergence. In the case of dual MPUs,
the standby MPU will first load the image file and initialize configuration. During active/standby
switchover, the LPUs do not need to be re-registered, and L2 and L3 interfaces will not be up/down.
In addition, the standby MPU has backed up forwarding entries so it can undertake the forwarding
task immediately to avoid service interruption.

Running Mechanism of Dual MPUs


In the case of dual MPUs, the status of the MPU is determined by the hardware upon startup.
Generally, the device selects the MPU in the slot with a smaller slot number as an active MPU, while
the hardware sets a delay for the MPU in the slot with a larger slot number so that it is started later.
Upon initial startup, two MPUs are in standby state and start software respectively. In general, the
MPU in the slot with a smaller slot number is an active MPU. If the active MPU fails, the MPU in the
slot with a larger slot number becomes an active MPU. If the device is restarted, the status of the
MPU in the slot with a larger slot number is active prior to restart. After the restart, the MPU in the slot
with a smaller slot number is still an active MPU.

Introduction to Hot Backup


Hot backup process
Hot backup of active and standby MPUs is divided into three stages: batch backup, real-time backup
and smooth data migration.
z

After the standby MPU starts, the active MPU synchronizes the standby MPU to store current
backup data on all modules, due to great difference between the active MPU and the standby
MPU. This process is called batch backup.

Hangzhou H3C Technologies Co., Ltd.

Page 5 of 20

H3C S12500 High Availability and High Reliability Technology White Paper
z

After batch backup ends, the system backs up data in real time, wherein the changes in the
backup data on the active MPU are also embodied on the standby MPU.

After active/standby switchover, the standby MPU becomes an active MPU to notify each module
of collecting data from LPUs and synchronizing data on LPUs. This process is called smooth
data migration.

After receiving data in real time, the standby MPU is upgraded to be an active MPU upon detecting a
switchover notification. The detection notification is triggered by interruption and hardware switchover
time for active/standby switchover is accurate to ms. After hardware is switched over, the status
machine of the new active MPU is in smooth state to smoothly process data.

Triggers of active/standby switchover


Triggers of active/standby switchover are classified into the following:
z

Run the active/standby switchover command in the command line to forcedly carry out
switchover.

A function of the active MPU fails.

The active MPU is hard reset or removed manually, which causes active/standby switchover.

On the active MPU, software is improperly restarted, which triggers switchover. For example, a
module takes up CPU for excessively long time, which causes the watch dog of hardware to
initiate restart; improper data access and command access lead to restart.

No matter which triggers switchover, the standby MPU is triggered by hardware interruption and
status switchover time is accurate to millisecond.

Reliability of Forwarding Plane


The forwarding plane of the S12500 series switches is not integrated on the MPU, which is different
from previous switches. It is installed on an independent switching fabric module architecture instead.
As a result, the control plane is physically separated from the forwarding plane, thus reducing the
impact of the control plane on the forwarding plane and freeing data switching from the influence of
MPU switchover.
Built upon an innovative Clos network architecture, the S12500 series switches support non-blocking
switching. In the S12500 series switches, LPUs form the first and third levels of a Clos network. The
switching network card on the switching fabric module is the medium level, each of which contains
one or more data planes.

Hangzhou H3C Technologies Co., Ltd.

Page 6 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

Figure 2 Clos interactive forwarding architecture

The biggest feature of the S12500s forwarding plane is N+M redundant backup of the switching
fabric module. In other words, the number of switching fabric modules can be greater than the
exchange capacity required by current forwarding. When a switching fabric module fails, the link
hardware on the backplane can detect and avoid it. In other words, data forwarding between LPUs is
forwarded to other network boards instead of the faulty link, thus reducing the influence of hardware
failures of switching fabric modules on services.

Reliability of Detection Plane


The S12500 series switches support an independent plane on which an independent OAM engine is
installed for rapid detection of BFD and RRPP without conflicting with other services, thus
guaranteeing reliability of rapid detection. Whats more important is that the OAM engine of the
S12500 series switches is located on the MPU, which greatly enhances performance of rapid
active/standby switchover.
Additionally, the S12500 series switches support online service detection. When the forwarding
function of the S12500 fails, the detection plane reports an alarm, which alerts users to isolate the
faulty part in advance.

Reliability of Support Plane


Reliability Technology of Power Supply
Because a power supply is the basis for guaranteeing devices running, it is necessary to configure
redundant power supplies. A high-end device requires higher reliability. To guarantee stable power
supply input, industry players always employ 1+1 redundant backup. Using a multiple-module power
supply, the S12500 supports X+N redundant backup. Users can run a command to set desired
redundancy. Furthermore, MBUS is used to control boards to be powered on in order to avoid
influence of concurrent power-on of components at an instant on the system.
Hangzhou H3C Technologies Co., Ltd.

Page 7 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

The S12500 series switches support independent power supply management and monitoring of
power supply status of boards, including voltage and current monitoring, and temperature monitoring
of POLA module. Users can run a query command to check system load and details on the power
supply module at any time.
Assuming that the number of actual in-position power supply modules is N, the effects arising from
configuration changes are as listed in Table 1:
Table 1 Configuration changes and corresponding effects
Configuration change

Effects

No configuration

When there is no alarm, the system can normally provide


supply when one power module fails.

The number of redundant


modules is 0.

The actual power supply capability is unchanged, but more line


card boards can be inserted without causing an alarm.
The redundant capability is enhanced.

From zero configuration to n


(n>1) redundant modules

When system load exceeds the power supply capability of N-n


power modules, an alarm is generated.
If there is no alarm, the system can normally provide supply
when n power modules fail.

Insert one power module.

Actual power supply capability is enhanced without changing


the redundancy capability. More line card boards can be
inserted without causing an alarm.

Remove one power module, but


system load is within the
redundancy capability.

Actual power supply capability is degraded without changing


the redundancy capability.

Remove one power module and


system load is beyond the
redundancy capability.

Actual power supply capability is degraded as well as the


redundancy capability, thus causing an alarm.

One power module fails.

An alarm is generated and actual power supply capability is


degraded.

Insert one LPU and system load


is beyond the redundancy
capability.

An alarm is generated.

Disable power supply


management.

No alarm is generated. When system load exceeds power


supply capability, the whole frame may be powered off.

Reliability Technology of Fan


As an important heat dissipation means, a fan is directly linked to the stable operation of the device.
Once the fan is faulty and heat cannot be dissipated in time, the interior of the device will create high
temperature and excessive heat, which may result in the burning of chips and boards. Fan
redundancy is also very important. The S12500 series switches provide two fan trays (in 1+1
redundant backup) so that fan trays can be changed on line without affecting normal running of the
device.

Hangzhou H3C Technologies Co., Ltd.

Page 8 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

The S12500 series switches support the detection of ambient temperature and fan speed adjustment
based on the device temperature, thus saving energy and guaranteeing timely heat dissipation of
boards. When temperature of one board is excessively high, the support plane reports an alarm and
powers it off in time.
Moreover, the S12500 series switches support alarm generation. When the hardware of a fan fails,
the S12500 reports an alarm to notify users of replacing the faulty hardware.

Hot Swapping Technology


Hot swapping technology refers to the direct inserting or removing of the component or board during
the operation of the device, which will not affect the other components or the services borne on the
boards. Hot swapping function includes:
z

Insert or remove a board in or from a frame without affecting the board which is being used.

Replace a board on line. In other words, when users remove a board and insert another board
(or insert the removed board again), the new board can inherit the original configuration without
affecting running of other boards.

All components in the S12500 series switches support hot swapping, including MPUs, power modules,
fans, and various LPUs. With the hot swapping function, users can maintain and update components,
deploy more services, and provide more functions, without interrupting services.

HA of Services
Introduction to NSF Technology
Figure 3 NSF schematic diagram
Active MPU
Original protocol
sessions are
switched over.

Standby MPU

Control

Control

Protocol sessions
are kept.

Switching plane

Control

FIB

Hangzhou H3C Technologies Co., Ltd.

FIB

Control

FIB

FIB

Page 9 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

As an important HA technology on the service plane, NSF ensures non-stop data forwarding when the
control plane of the switch fails, for example, fault-triggered restart or routing oscillation, thus
preventing various streams of the network from being impacted. To support NSF, a device should
meet the following two requirements:
z

The device should adopt the distributed architecture, with data forwarding separate from control,
and support dual MPUs. When an active/standby switchover takes place, the standby MPU must
save IP/MPLS forwarding entries (forwarding plane) successfully.

Status (control plane) of some protocols can be saved.

For OSPF, IS-IS, BGP, LDP and other complicated protocols, it costs a lot or it is impossible to
completely back up complicated status of the control plane. In contrast, by partly backing up some
protocol status (or not backing up protocol status) and the help of adjacent devices, session
connections on the control panel are not reset in the case of active/standby switchover so that
forwarding is not interrupted.
Figure 4 GR schematic diagram

The technology for not resetting the control plane is called graceful restart (GR) of routing protocols,
which shows that forwarding is not interrupted when routing protocols are restarted.
The core of the GR mechanism is when the routing protocol of a device is restarted, it informs
adjacent devices of keeping the neighbor relationship and routes to the device stable for a certain
period. After the routing protocol is completely restarted, the adjacent devices help the device to
synchronize the routing information and restore the routing information of the device to the state
before the restart within the shortest time. During the entire protocol restart, network routes and
forwarding are kept highly stable. The packet forwarding path is not changed in any way. The whole
system can forward IP packets continually.
The S12500 series switches support GR for OSFP/BGP/IS-IS/LDP/RSVP. When the active/standby
switchover of MPUs takes place, the peer device continues keeping the protocol neighbor relationship
with the local device, thus avoiding network oscillation and guaranteeing network stability.
Hangzhou H3C Technologies Co., Ltd.

Page 10 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

High Reliability Technology of Link


Link Aggregation Technology
Link aggregation technology is also called trunking or bonding technology. The essence of the
technology is that a number of physical links between two devices are combined into a logical data
channel, called an aggregated link, as shown in Figure 5. Two physical links between switches form
an aggregated link. Logically the link is a totality. The internal composition and details of data
transmission are transparent to the upper-level services.
Figure 5 Schematic diagram of link aggregation

The physical links within the aggregation jointly complete the tasks of data transmitting/receiving, and
provide backup to each other. As long as the aggregation has a normal member, the whole
transmission link will not fail. As shown in Figure 6, if Link 1 fails, data tasks of Link 1 are rapidly
transferred to Link 2 and data streams between two switches are not interrupted.
Figure 6 Mutual backup of link aggregation members

The S12500 series switches support manual aggregation, dynamic aggregation, intra-board
aggregation, and inter-board aggregation.

RRPP Technology
Dedicated to Ethernet rings, RRPP is a link layer protocol, which avoids broadcast storm caused by
data loops on a complete Ethernet ring. When one link on the Ethernet ring is cut off, RRPP rapidly
restores communication path between nodes on the ring network. Most MANs and enterprise
networks are ring networks to guarantee high reliability. However, failure of any node on the ring may
affect services.
Currently, STP and RRPP are common technologies used to solve loop problems on L2 networks.
STP applications are relatively mature, but convergence is accurate to second. As a link layer
protocol dedicated to Ethernet loops, RRPP supports faster convergence than STP. In addition,
convergence time supported by RRPP is irrelative to the number of nodes on the ring network. RRPP
can be applied to the networks with long diameters.
The S12500 supports RRPP multiple instances and establishment of multiple RRPP networks, thus
meeting the flexibility requirements of networking.
Hangzhou H3C Technologies Co., Ltd.

Page 11 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

Figure 7 RRPP networking

Domain 1
Device A

Device B

Transit node

Master node
Ring 1

Transit node

Transit node

Device D

Device C

Polling mechanism is that for master nodes on the RRPP ring to actively detect health of the ring
network.
The master node regularly sends Hello packets from its master port, which are transmitted on the ring
by passing each transmit node in turn. If the loop is healthy, the secondary port on the master node
receives the Hello packets before the timer expires and the master node keeps the blocking status of
the slave port. If a loop is cut off, the secondary port on the primary node cannot receive Hello
packets before the timer expires, the master node removes the blocking status of data VLAN on the
secondary port and sends a Common-Flush-FDB packet to notify all transmit nodes of updating their
own MAC entries and ARP/ND entries.
When discovering one of their ports in the RRPP domain is down, a transmit node, an edge node, or
an auxiliary edge node sends a Link-Down packet immediately to the master node. After receiving the
Link-Down packet, the master node removes the blocking status of the data VLAN on its secondary
port and sends the Common-Flush-FDB packet to notify all transmit nodes, edge nodes, and auxiliary
edge nodes of updating their own MAC entries and ARP/ND entries. After each node updates its own
entry, data streams are switched over to normal links.
In addition, RRPP can be configured on an aggregation group and link reliability is guaranteed by
aggregation and RRPP.

Smart Link Technology


A Smart Link group is also called a flexible link group. Each Smart Link group contains two ports only.
One is an active port and the other is a standby port. Normally, only one port is in active state, while
the other port is blocked, in standby state. When the link of the active port fails, the Smart Link group
automatically blocks this port and the standby port is switched over to be an active port. For example,
the port is down and OAM unidirectional link occurs. In addition, Smart Link can be configured on an
aggregation group and link reliability is guaranteed by aggregation and Smart Link.
Smart link meets the requirement for rapid link convergence and also backs up active/standby links
for redundancy and rapidly migrates active/standby links. In the networking with two uplinks, when the
Hangzhou H3C Technologies Co., Ltd.

Page 12 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

active link fails, the device automatically switches over traffic to the standby link, thus backing up links
for redundancy. The main characteristics are as follows:
z

Dedicated to two uplinks

Rapid convergence (accurate to sub-second)

Simple configuration, which facilitates user operation

When a Smart Link is switched over, MAC address forwarding entry and ARP/ND entry on each
device on the network may not be the latest. To properly send packets, a mechanism for updating
MAC address forwarding entries and ARP/ND entries should be provided. Currently, two update
mechanisms are available:
z

Automatically update MAC address forwarding entries and ARP/ND entries by traffic. This mode
is applicable to interconnection to the devices (including the devices of other vendors) that do not
support Smart Link. It should be triggered by upstream traffic.

A Smart Link device sends Flush packets from a new link. This mode requires upstream devices
to identify Flush packets on the Smart Link and update MAC address forwarding entries and
ARP/ND entries.

When the original active link is failed over, the port is still in standby state without link status
switchover, thus keeping traffic stable. This port is switched to be active only after next link switchover.
Smart Link supports multiple instances. In different Smart Link instances, one port can assume
different roles. For example, in instance 1, a port is an active port, while in instance 2, the port is a
standby port. In this case, traffic load of different instances can be balanced between ports.

DLDP Technology
A special phenomenon occurs during actual networking, namely, unidirectional link. Unidirectional link
means that the local end can receive the packets sent by the peer end over the link layer, but the peer
end cannot receive the packets sent by the local end. Unidirectional link leads to a series of problems,
such as loop in spanning tree topology.
Take fiber as an example. A unidirectional link is classified into two cases: fibers are cross-connected;
one fiber is disconnected or one fiber is cut off. As shown in Figure 8, crossed fibers refer to the fibers
which are connected reversely. As shown in Figure 9, hollow lines indicate that one fiber is not
connected or one fiber is cut off.

Hangzhou H3C Technologies Co., Ltd.

Page 13 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

Figure 8 Cross-connect of fibers

Device A
GE2/0/1

GE2/0/1

GE2/0/2

Device B

GE2/0/2

PC

Figure 9 One disconnected fiber or one broken fiber

Device A
GE2/0/1

GE2/0/1

GE2/0/2

Device B

GE2/0/2

PC

DLDP can monitor link status of fibers or copper twisted pairs. If a unidirectional link exists, DLDP
automatically disables related ports or notifies users of manually disabling them according to user
configuration to prevent network problems.
DLDP is a link layer protocol, which is used together with the protocols at the physical layer to monitor
link status of devices. The automatic negotiation mechanism at the physical layer detects physical
signals and faults. DLDP identifies peer devices and a unidirectional link, and disables an
unreachable port. DLDP and the automatic negotiation mechanism at the physical layer work together
to detect and disable physical and logical unidirectional connection. If the links at both local end and
remote end can work properly at the physical layer, DLDP detects whether these links are properly
connected and whether two ends can properly exchange packets at the link layer. This detection
cannot be implemented by the automatic negotiation mechanism.
DLDP has the following two working modes:

Hangzhou H3C Technologies Co., Ltd.

Page 14 of 20

H3C S12500 High Availability and High Reliability Technology White Paper
z

Common mode: In this mode, once the aging timer of a neighbor expires, one Advertisement
packet with RSY label is sent concurrently when the neighbor entry is deleted.

Enhanced mode: In this mode, once the aging timer of a neighbor expires, the enhanced timer is
started. Every one second, one Probe packet is sent to actively detect the neighbor. Eight Probe
packets are continuously sent. If an Echo packet from the neighbor is not received when the
Echo wait timer expires, the device is disabled.

The enhanced mode aims to detect a network black hole to prevent that one end is up and another
end is down. When a port is set to forced rate and forced full duplex mode, some devices may
experience the cases as shown in Figure 10. In fact, port B has been down, but a common link layer
protocol cannot detect that it has been down. As a result, port A is still up. In the enhanced mode, port
A initiates a probe after the aging timer of a neighbor expires. If port A does not receive Echo packet
of port B after Echo wait timer expires, port A is disabled. Because physical status of port B is down,
DLDP status of port B is inactive.
Figure 10 Enhanced DLDP mode

In common mode of DLDP, the system can identify one type of unidirectional link only: crossconnected fibers.

In enhanced mode of DLDP, the system can identify two types of unidirectional links. One is
cross-connected fibers, and the other is one disconnected fiber or one broken fiber. When
detecting the unidirectional link of the latter type, a port should be set to work in forced rate and
forced full duplex modes. Otherwise, even if DLDP is enabled, DLDP is invalid. When the
unidirectional link of the latter type occurs, the port that has optical signal at the receive end is
disabled, while the port that does not have optical signal at the receive end is inactive.

High Reliability Technology of Network


Network reliability technologies include the following:
z

VRRP

Equivalent route

BFD

FRR, including IP FRR, MPLS TE FRR

VRRP
As shown in Figure 11, a default route with the gateway as the next hop is set for all the hosts in the
same network segment. The packet sent by the host to other network segments is sent to the
gateway through the default route, and then forwarded by the gateway, thus completing
communication between the host and the external network. When the gateway is faulty, all hosts
within the network segment with the gateway as the default route cannot communicate with the
external network.

Hangzhou H3C Technologies Co., Ltd.

Page 15 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

Figure 11 Common LAN networking

The default route provides convenience to configuration operation of users. However, it poses a high
requirement on stability of the default gateway. Adding more egress gateways is a common method to
improve system reliability. In that case, the way to select a route among multiple egresses becomes a
pending issue.
VRRP is an error tolerance protocol, which solves the preceding problems well by the separation
between physical devices and logical devices. On a LAN with multicast or broadcast capability, for
example, Ethernet, highly reliable default link can still be provided with the help of VRRP when a
device is faulty. Network interruption caused by the fault of a single link is avoided. There is no need
to modify the dynamic routing protocol, routing discovery protocol and other configuration.
According to VRRP, a group of routers within the LAN are put together as a VRRP group. The VRRP
group consists of a master router and multiple backup routers, which is equivalent to a virtual router
regarding functions. Figure 12 shows the typical networking of VRRP.
Figure 12 VRRP typical networking scheme
Virtual router
Switch A
Host A

Switch B

Network
Host B
Switch C

Host C

The S12500 series switches support VRRP. The S12500 series switches support 256 VRRP groups
and BFD for VRRP high-speed detection to achieve 30 ms fault checking and 50 ms service
switchover.
Hangzhou H3C Technologies Co., Ltd.

Page 16 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

Equivalent Route
Figure 13 Equivalent route implementation mechanism

The S12500 series switches support equal-cost multi-path routing (ECMP). Each route supports eight
equivalent paths for load balancing of IP or MPLS traffic and also supports Hash load balancing by
driving traffic. ECMP minimizes occurrence of disordered packets. After path switchover, traffic is
rapidly switched over to other active links, thus guaranteeing service reliability.

BFD
BFD is a networkwide unified detection mechanism for fast detecting and monitoring the connectivity
of network links or IP route forwarding. To improve the existing network performance, the adjacent
protocols should be able to fast detect a communication fault, thus quickly establishing a backup
channel to restore communication.
z

BFD: Defined by the IETF, BFD rapidly detects faults of nodes and links. By default, the
handshake time is 10 ms. BFD enables detection with light load and short duration. BFD can
detect any medium and any protocol layer in real time. The detection time and overhead range
are wide.

BFD can detect faults on any type of channel between systems, including direct physical link,
tunnel, MPLS LSP, multi-hop routing channel and indirect channel.

BFD detection results can be applied to IGP fast convergence and FRR.

BFD protocol has been accepted and recognized by the industry and deployed widely.

Hangzhou H3C Technologies Co., Ltd.

Page 17 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

Figure 14 BFD implementation mechanism

The S12500 series switches fully support BFD for VRRP/BGP/IS-IS/OSPF/RSVP/VPLS PW/static
routing. On the basis of the dual planes (control plane and forwarding plane) of the traditional core
switch, the switches adopt the unique design of the detection plane. The plane monitors network
faults. It helps to implement 30 ms fault detection and 50 ms service switchover, ensuring that
services are not interrupted. The detection plane and the control plane & forwarding plane are
independent from each other and will not affect each other. They provide carrier-class equipment
reliability and network reliability to users. A test shows that BFD switchover time of the S12500 is
shorter than 50 ms.

IP FRR
The interruption of traffic transmission caused by a link or node fault on the network is restored only
when the route is re-converged on the new topology. During the time interval between interruption
and restoration, the packets that can reach the destination by penetrating the faulty part will be lost or
undergo a loop. The route convergence process consists of the following aspects:
1)

Fault detection time

2)

Re-propagation time of the routing information (including the generation and propagation time of
LSA/LSP)

3)

Route calculation time (including the time for LSDB route calculation after the change)

4)

Route delivery time (including inter-board synchronization of FIB entries and time for delivery to
the driver)

Currently, a number of new technologies are used in fast convergence of routing protocols. For
example, shorten fault detection time by BFD, lessen the time for re-propagating routing information
by Fast Flood, and decrease the time for route calculation by ISPF and PRC. As a result, route
convergence is greatly quickened. Currently, in the case of 10,000 routes, traffic interruption time
caused by a network fault can be within one second.
However, voice, video and other new network services pose more stringent requirements on the
traffic interruption time. A large number of carriers hope to control the traffic interruption time caused
by network faults within 50 ms or less. This requirement cannot be satisfied by the traditional routing
protocol fast convergence technologies.
At present, the new method that is being researched for meeting such a requirement is to calculate
backup route in advance. In other words, when detecting a fault, a router does not disseminate route
Hangzhou H3C Technologies Co., Ltd.

Page 18 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

information or calculate a route at once. Instead, the router replaces the failed route with the backup
route to directly rectify the fault locally. During the process when the whole new route completes reconvergence, the pre-determined backup route is used for forwarding. In this case, traffic interruption
time which is equal to the sum of the time for detecting an adjacent fault and the time for replacing the
failed route with a backup route is greatly shortened. The new technology of using local preset repair
path to provide protection for the failed link or router is called IP FRR.
Figure 15 IP FRR
Switch C

Switch A

Switch B

Fault

Switch D

Switch E

The basic principle for IP FRR is as shown in Figure 15. Normally, the routing table of Switch B
indicates that the packets with the destination of Switch E should be forwarded by Switch D. In
addition, a backup path is added to the routing table of Switch B, that is, the packets with the
destination of Switch E can be forwarded by Switch C. When detecting a link fault between Switch B
and Switch D, Switch B forwards the packets with the destination of Switch E to the backup next-hop
Switch C.

MPLS TE FRR
MPLS TE FRR is a mechanism for link protection and node protection. When an LSP link or a node is
faulty, protection is performed at the faulty node to allow traffic to go through the tunnel of the
protected link or node. In that way, data transmission is not to be interrupted. At the same time, the
head node can continue to initiate re-establishment of the main path without affecting data
transmission.
The basic principle of MPLS TE FRR is to use a pre-established LSP to protect one or more LSPs.
The pre-established LSP is called FRR LSP and the protected LSP is called main LSP. The ultimate
goal of MPLS TE FRR is to use the bypass tunnel to bypass the faulty link or node, thus protecting
the main path.
MPLS TE FRR is implemented on the basis of RSVP TE. There are two modes for implementing FRR;
z

Detour: One-to-one Backup. Each protected LSP is protected, and a protection path is created
for each protected LSP. The protected path is called Detour LSP.

Bypass: Facility Backup. One protection path is used to protect multiple LSPs. The protected
path is called Bypass LSP.

The Detour mode provides protection to each LSP, requiring a relatively large amount of overheads.
In fact, Bypass mode is more widely used than Detour mode.

Hangzhou H3C Technologies Co., Ltd.

Page 19 of 20

H3C S12500 High Availability and High Reliability Technology White Paper

Figure 16 MPLS TE FRR

The S12500 series switches support MPLS TE FRR. It ensures 50 ms carrier-class switchover
performance by the BFD for RSVP fast detection mechanism.

HA of Software Maintenance (Software Hot Patch on


Line)
Figure 17 Online patch

The S12500 series switches can modify software bugs or add a small scale of new features on line
without restarting the devices. They provide commands for controlling status switchover of patch units
so that users can easily load, activate, deactivate, run and delete a patch unit.

Copyright 2009 Hangzhou H3C Technologies Co., Ltd. All Rights Reserved.
Any company and individual shall not excerpt and/or duplicate the content of this document, in part or in full, without the written consent of
H3C, and shall not propagate the content in any form.
This document is subject to change without prior notice.

Hangzhou H3C Technologies Co., Ltd.

Page 20 of 20

Вам также может понравиться