WATERPROOF YOUR
BATHROOM IS WHEN
ITS ON PAPER
Content
Introduction 03
Impact of a leaking bathroom
04
05
08
09
Bill of quantity
13
BATHROOMS
A life-style space...
Nowadays bathrooms are not just a space to freshen up but is visualized as a personal space to get
refreshed and rejuvenated. Substantial amount of time and investment is put in to build bathrooms as
per an individuals choice.
Tile
Latex membrane
Screed
Brickbat coba
Bathseal System
Gaps around
pipe inserts
Gaps around
nahani traps
Waterproofing
of sunken
portion
Gaps around
sanitary wares
Wall Slab
Junction
Splash zone
(Shower area)#
Solutions
recommended
Area of application
Non-shrink expansive,
cementitious free
flowing grout for filling
gaps around bathroom
pipes
Acrylic elastomeric
Cementitious waterproof
coating for sunken
portion and walls in
bathroom
Recovery - Accommodates
expansion & contraction
Excellent waterproofing
characteristics
Polymer modified
cementitious tile joint
filler
Polymer based
Waterproof
Non-dusting
Easy to use and clean
Mixing pot
Broom
Notched trowel
Vacuum cleaner
Wire Brush
Chisel
Measuring tape
Hammer
Marker/ ink
Paddle mixer
Hand trowel
Sponge
Water bucket
Other products required for waterproofing
Dr. Fixit Pidicrete URP
Dr. Fixit Pidiproof LW+
Clean water
Glass Fibre mesh
Clean & washed sand
Tile
1500 mm
Screed
300 mm
100 mm
WET AREA
1800 mm
DRY AREA
Concrete slab
Sandwiched fibre mesh
Dr. Fixit Bathseal Grout
Dr. Fixit Bathseal Tape
Tile
1500 mm
Brickbat coba
Screed
WET AREA
1800 mm
DRY AREA
300 mm
b. A
pply Dr. Fixit Bathseal
Sealant around periphery
of pipe after grout is set.
b. H
orizontal pipe inserts
should be sealed using
Dr. Fixit Bathseal Tape
& Grout internally &
externally with Dr. Fixit
Pidicrete URP mixed
mortar, as shown in the
sketch above.
B. Surface Preparation
Clean the wall and floor surface thoroughly to ensure no dust, grease or oil is left on it.
a
e. S
aturate the surface with
water.
10
b. T
reat uneven surface
or surface cracks
using polymer modified
mortar.
f. R
emove excess water
using sponge. Before
application the surface
should be at saturated
surface dry (SSD)
condition.
c. Provide 50 mm x 50 mm
angle fillets using cement
sand mortar mixed with
Dr. Fixit Pidicrete URP at
all wall to floor junctions.
b. M
ark the wall splash zone
up to 300 mm on all
4 walls as well as 1500
mm wide by 1800 mm
height on shower splash
area.
c. K
eep the substrate in
Saturated Surface Dry
(SSD) condition and
then apply first coat on
areas marked on wall
and covering entire floor.
Coating should also be
extended up to 150 mm
on slab of dry area on
floor.
d. While
the coating is
still wet, place the
150 mm wide strip of
glass fibre mesh on the
angle fillet & allow it to
soak completely. Apply
immediately one more
coat on angle fillet, thus
embedding mesh firmly
between 2 coats of
Dr. Fixit Bathseal WPC.
11
b. F
ill the water up to height
of 25 to 50 mm. Water
level should not exceed
above level of coating
on wall. Leave it as is for
24 hrs. and check for
water leakages.
12
b. G
aps around bath tubs,
wash basins, electric
fixtures should be filled
using Dr. Fixit Bathseal
Sealant.
d. L
ay a 40 to 50 mm
screed to proper slope,
using cement to sand in
1 : 3 ratio, with addition of
Dr. Fixit LW+.
BILL OF QUANTITY
Sr.
No.
Description of work
Unit
Item
L. M.
No.
Qty
Rate
Amount
Sq. Mtr.
Item
13
NOTES
14
15
CONTACT US: Ahmedabad (079) 27552043/ 1483 Bengaluru (080) 30563000/3001 Chennai (044) 28350338/ 1614 Delhi (011) 45529000
Hyderabad (040) 23351250/ 1308 Kochi (0484) 2543978, 3045000 Kolkata (033) 22888844 Mumbai (022) 2835 7000
OVERSEAS CONTACTS: Dubai +9714 3471678 Singapore +65 67638681 Thailand +66 27228535
DISCLAIMER The product information & application details given by the company & its agents has been provided in good faith & meant to serve only as a general guideline during usage. Users are
advised to carry out tests & take trials to ensure on the suitability of products meeting their requirement prior to full scale usage of our products. Since the correct identification of the problems,
quality of other materials used and on-site workmanship are factors beyond our control, there are no expressed or implied guarantee/ warranty as to the results obtained. The Company does not
assume any liability or any consequential damage for unsatisfactory results, arising from the use of our products.
113CC0035-DF-BSBRO-ENG-JAN-13