Вы находитесь на странице: 1из 44

*

our
E
ludes
c
E
in
FR
ring
Now
D
t offe
c
u
A
d
E pro

Water Pressure
Reducing Valves

watts.com

Table of Contents
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5
Performance Curves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

67

Water Pressure Reducing Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8


Series LFU5B Water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

89

Series LF25AUB-Z3 Water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10 11

Series LFX65B Water pressure reducing valves (12" 2"). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12 13

Series LF45B-M1 Water pressure reducing valves (34" 1"). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14 15

Series LFN45B-EZ Water pressure reducing valves (34" 1"). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16 17

Series LF223, LF223S High capacity water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 19


Series LFN223B, LFN223BS Super capacity water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20 21

Series LFN223F, LFN223FS Flanged super capacity water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . .

22 23

Series LF127W and LFF127W High capacity water pressure reducing valves . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24 25

Series 2300 Direct operated water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26


Series 115/1115 Water pressure reducing automatic control valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Series LFN250, LFN250B Iron body water pressure reducing valves with integral strainer . . . . . . . . . . . . . . . . . . . . . . . 28
Series LF26A, LF263A Small water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Series SS263AP Stainless steel water pressure reducing valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Series P60-M1 Plastic miniature water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Series LF560, LFH560 Water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Series LF123LP Water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Series LF215 Super sensitive low pressure water pressure regulators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Model 276H300, IWTG Hose connection gauges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Series LFDPG-3 Center back-entry pressure gauges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Series LFDPG-5 Top entry pressure gauges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Jumper Kits Temporary bypass for water pressure reducing valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

General Information
Ensuring Practical, Safe Working Water Pressure
Water pressure reducing valves have
been in use since 1874, when Watts
regulators were used to reduce the
pressure of incoming water to industrial
operations. Subsequently, they have
been adapted for residential and commercial use.
The most important and practical reason that water pressure reducing valves
(WPRVs), also known as pressure regulators, are used is protection against the
effects of high water main pressures.
Municipal and private water supply companies use pumps and pumping stations

to boost water supply pressures in supply mains in order to supply water for fire
fighting, to overcome loss of pressure as
the elevation increases in high rise buildings, and to maintain water supply in
water towers and supply tanks. Pressure
in water supply mains can exceed
200psi.
Most plumbing codes require water pressure reducing valves on domestic systems where the municipal water mains
pressure exceeds 80psi. Higher pressures could rupture pipes, damage fixtures, and injure the people using them.

Promoting Water Conservation


High water pressures waste water.
Anyone concerned with conserving
water, a vital and increasingly expensive
resource, should be interested in reducing
water consumption and the associated
costs. Many municipalities today not only
charge homeowners and businesses high
rates for water consumption, but also
charge consumers equally high rates for
the disposal of wastewater. Furthermore,
conserving water reduces the excess

energy required for heating additional hot


water. Watts water pressure reducing
valves have proven themselves over the
years by ensuring efficient water distribution, longer life for the entire plumbing
system, and considerable savings in
water and energy consumption.

Why Do You Need a Watts Water Pressure Reducing Valve?


Common practice and analysis indicate
that 50psi or less is sufficient inflow pressure for most home and commercial
purposes. The higher the pressure the
more water resources are wasted. Watts
water pressure reducing valves help save
money, energy, system maintenance, and
wastewater returned to the environment
(see Fig. 1).
W
 ater Savings: Twice as much water
flows through a system at 150psi pressure than at 50psi. Much of this additional water is wasted.

Energy Savings: If less water flows


through the system, then less energy
is needed to heat domestic hot water.
Calculations show that a Watts water
pressure reducing valve can save as
much as 30% on domestic water heating
costs.
W
 astewater Savings: When the communitys wastewater treatment load is
reduced, cost benefits accrue to both
the environment and your bottom line.
Many municipalities prorate sewer
usage fees based upon the water
meter reading.

What is a Water Pressure Reducing Valve?


There are two types of water pressure reducing valves: directacting and pilot-operated. Both use globe- or angle-style bodies. Valves used on smaller piping diameter units are
cast from brass; larger piping diameter units are made
from ductile iron. Direct-acting valves, the more
popular type of water pressure reducing valve,
consist of globe-type bodies with a springloaded, heat-resistant diaphragm.

This diaphragm is connected to the outlet of the valve


which in turn acts on a spring. This spring holds a
pre-set tension on the valve seat installed with
a pressure equalizing mechanism for precise
water pressure control.

Pilot-Operated Valve

Fig. 1 Faucet with 10


minutes running time

Direct-Acting Valve

How Does a Watts Direct Acting Water Pressure Reducing Valve Work?
Water pressure regulators are installed
in series directly after the water meter
in homes, commercial buildings, and
manufacturing plants. The water pressure
reducing valve automatically reduces the
pressure from the water supply main to
a lower, more sensible pressure. Water
entering the valve from municipal mains
is constricted within the valve body and
directed through the inner chamber; this
inner chamber is controlled by an adjustable spring-loaded diaphragm and disc.

Even if the supply water pressure fluctuates, the pressure reducing valve ensures
a constant flow of water at a functional
pressure (as long as the supply pressure
does not drop below the valves pre-set
pressure).

Spring
Diaphragm

Seat

Disk

Inlet

Outlet

Thermal Expansion Bypass Technology


The installation of a water pressure
reducing valve on the potable water
distribution line creates a closed
plumbing system, since water can no
longer return to the supply main. A
Thermal
water heater installed in the system
Expanded
will cause the water in the heater to
Pressure
expand, a condition known as thermal expansion. Thermal expansion
Reduced can cause problems with the heaters
Pressure temperature and pressure (T&P) relief
valve. Watts water pressure reducing
Initial Pressure
valves offer a patented, integral bypass
check valve feature that eliminates
frequent dripping of T&P relief valves
caused by thermal expansion. Under
Inlet Seat and Disc
normal operation, the check valve is
held closed by the street main presFig. 2 Watts Thermal Expansion Bypass feature
sure. However, should thermal expansion pressure rise just 1psi higher
than the supply pressure, the bypass
opens, passing the expanded water
back to the supply main. The expanding water is dissipated and the temperature and pressure relief valve is
not affected.
Thermal Expansion
Bypass Feature

The effectiveness of the bypass feature is


limited to systems where the supply pressure is less than the pressure setting of
the relief valve. The bypass model in no
way replaces a water heater temperature
and pressure (T&P) relief valve, which
is a necessary precaution against other
causes of excessive pressure. Even with
a bypass feature installed, the installation
of a backflow preventer or check valve on
the water meter and/or high service pressure may also require a thermal expansion control device. Watts offers both
thermal expansion tanks as well as thermal expansion relief solutions. For more
information on these products reference
literature PG-ThermExpansion.

NOTICE
The bypass feature will not prevent the
pressure relief valve from opening on
the hot water supply system with pressures above 150psi.

Sizing a Water Pressure Reducing Valve for Your Application


A properly sized valve prevents noisy
operation or premature valve failure. Over
sizing water pressure reducing valves
can lead to problems such as wire draw
under low flow conditions. In general, the
minimum flow through a water pressure
reducing valve should be 10% to 15%
of the maximum flow rate desired in the

system. Also, water pressure reducing


valves should be selected based on the
flow and pressure ranges listed in the
literature, not the size of the pipe where
they are attached. You should select a
regulator where operating pressures fall
within the middle of its rated range.

For example, imagine you want to create a working pressure of 50psi within
a building with a flow rate of 35 to 40
gpm, and a reduced pressure fall-off of
20psi, working with a supply water pressure of 150psi. Using Table I, on page 4
(example 1), you would choose to use a
1" Watts LF25AUB-Z3.

Choosing the Correct Installation Configuration


Watts water pressure reducing valves
can increase your water systems performance, reduce operating costs, and
ensure a longer life for other plumbing
fixtures. Most simple pressure reducing
applications require a single regulator.
However, there are applications that

require more than one unit installed in a


specific system configuration.

consider using a two-stage, serial reduction configuration.

When there is wide variation in pressure


between the municipal mains inflow pressure and the functional pressure needed
within the building, or when the mains
pressure exceeds 200psi, you should

When you want to maintain a continuous


supply of water at reduced pressures you
should consider a parallel installation.

Two-Stage Serial Reduction Configuration


The two-stage serial reduction approach
uses two valves in series to reduce or
eliminate extreme variations between
the water mains inflow pressure and the
desired, final reduced pressure. Twostage reduction is recommended when
initial pressures are 200psi or greater,
or when the desired pressure reduction ratio is greater than 4:1, e.g., from
200psi to 50psi, or where the inflow
pressure fluctuates greatly.
The advantage of two-stage serial reduction is that neither valve is subjected to
extreme pressure differential, thus prolonging valve life and delivering more precise pressure regulation.

LFU5B-Z3 valve and a 112" Series LF223S


valve exceed the 80 gpm capacity at either
a 10psi or 15psi fall-off pressure (example
2). You should then select the appropriate
valves based on relative product cost and
performance at lower fall-off pressures.

Selecting the proper valves and pressure


settings is straightforward. For example in
Fig. 3, the first regulator in series reduces
the mains pressure of 250psi to 150psi,
and the second regulator reduces the
pressure from 150psi to approximately
50psi. A similar ratio should be used no
matter the initial inflow pressure.

Valve sizes and capacities should be


112" LFU5B-Z3-HP
selected from the capacity table (see
Table I) below. Remember, each valves
flow capacity should exceed the total
flow requirement of the system. For
example, assume that the desired
system capacity is 80 gallons
Supply Pressure
per minute (gpm). In reviewing
250psi
Table I, we find that a 2" Series

112" LFU5B-Z3

Reduced
Pressure
150psi

Final
Reduced
Pressure
50psi

Fig. 3 Two-stage serial reduction configuration

Table I
Summary of Capacities of Watts Water Pressure Reducing Valves
Table shows capacity in gallons per minute based on various reduced pressure fall-off.
c = Example 1
= Example 2

Capacity (gallons per minute)


fall-off
LFU5B-Z3 LF25AUB-Z3 LF223
- LF223S
PRESSURE

5psi
10psi
15psi
20psi

2"

4" 1" 114" 112" 2" 12"

4" 1" 114" 112" 2" 12"

4" 1" 114" 112" 2" 212"

5 6 7 9 12 30 2 3 5 3 5 15 8 10 12
16 37
50
60
10 13 20 25 32 60 5 7 10 10 10 28 16 20 29 46 80 100
105
12 21 30 40 52 84 10 15 22 26 33 55 20 29 40 70 107
136
143
17 27 40 50 64 100 16 25 38 52 60 85 23 36 50 88 132
162
170

For average installations and applications, the capacities shown at 20psi fall-off are recommended since statistics show that typical
demands are well within the total sized capacity of the system. Capacities at 15, 10, and 5psi are offered for comparison and where a lesser
fall-off is needed or required for maximum performance or a specific application.

Parallel Installation
The parallel installation makes use of
two or more smaller size water pressure
reducing valves serving a large size supply pipe main (see Table III on page 5
for reference). This approach should be
used wherever there is a wide variation
of reduced pressure requirements such
as an apartment building where demand
could be .5 gpm at 1am and 100 gpm
at 6am and where you must maintain a
continuous water supply. Parallel installations also offer the advantage of providing
increased capacity where needed beyond
that provided by a single valve. In addition,
the parallel configuration improves valve
performance for wide variable demands
and permits servicing of an individual valve

without shutting down water flow


to the building completely, thus
avoiding costly shutdowns. (The
extra piping is not a factor inasmuch as the secondary valve
uses the piping bypass line that
is always recommended in the
installation of larger size regulators).
For a two-valve installation
as shown, the total capacity
of the valves should equal or
exceed the capacity required by
the system. One valve should be
set at 10psi higher delivery pressure than the other. For example,
assume that the system is piped

2" LF223
Set at 60psi

2" LF223
Set at 50psi

Reduced
Pressure

4" Supply Main

Table II

Fig. 4 Parallel Installation

Note: The lower set valve is recommended


to be located on the main run with the higher set valve located on the saddle for easier
maintenance of this 100% used valve.

Summary of Capacities of Watts Water Pressure Reducing Valves


Table shows capacity in gallons per minute based on various reduced pressure fall-off.
= Example 3
= Example 4
fall-off

Capacity (gallons per minute)
PRESSURE
LF223
- LF223S LFN223B LFN223F LF127W

2"

4" 1" 114" 112" 2" 212" 212" 3" 3" 3" 4"

5psi 8 10 12 16 37 50 60 60 85 70 75 80
10psi 16 20 29 46 80 100 105 130 180 120 130 140
15psi 20 29 40 70 107 136 143 200 280 160 180 230
20psi
23 36 50 88 132 162 170 285 375 210 250 300

for 265 gpm and the delivery pressure


required is 50psi. One valve should be
set at 50psi, with the other valve set 10psi
higher at 60psi. Thus, when low volume is
required, the higher set valve operates alone.
When a larger volume is needed, both
valves open, delivering full line capacity.
Now, select from Table II, on page 4, two
valves whose total capacity equals or
exceeds 265gpm. Referring to the Series
LF223 in Table II (example 3), note that
the 2" size offers a capacity of 136gpm,
at a 15psi fall-off (totaling 272gpm). Or
the 212" size, Series LF223 has a capacity of 143gpm at a 15psi fall-off (totaling
286gpm). Thus, the 2" size Series LF223
would appear to be adequate since excellent flow would be provided between
15psi and 20psi fall-off, not to mention
lesser fall-offs for typical lower demands.
Parallel Installation of Same Size
Regulators
Use Table III, shown below, as a convenient reference for choosing the various
combinations of regulators of the same size
whose equivalent capacity matches that of
a larger valve or pipeline capacity. Although
Table II shows only two-valve combinations
of the same size, three valves can also be

used. It is only necessary that the sum of


the valves capacities equal the system
requirements.
For example, as shown in Table II, a
system requiring 275gpm at 20psi falloff pressure could use two of the 3"
LFN223F valves or two 212" LF223s.
The final selection would be based on
the comparative potential capacity performance of 20psi fall-off pressure.
We recommend restricting installations
to two valves for most applications to
avoid excessive pressure drop and to
assure more precise control of reduced
pressure. The number of regulators used
should be determined by the engineers
judgment, based on operating conditions for a specific installation.
Parallel Installation of Different Size
Regulators
Another type of parallel installation is one
using a two-valve combination of different
sizes. This would be practical on larger
commercial or institutional installations
where supply lines are 2" and larger and
where there are frequent periods of low
volume demand. In such cases, the
smaller valve would have the 10psi higher
delivery pressure and thus operate alone

to satisfy small demands such as for the


flushing of urinals or for supply to drinking
fountains. When a larger volume is required,
the main regulator would open to satisfy the
system demand, for example for an apartment building requiring 275gpm. In this
case, selection could be a 4" LF127W and
a 1" LF223 as shown in Table II, Example
4.
Table IV Shows the average rate of water
flow in pipe lines which is used quite generally
in supply system design. Watts water pressure reducing valves are designed to equal or
exceed these capacities.

Pipe Size

gpm Flow

2" 10
4" 16
1"
25
114" 41
112" 55
2"
84
212" 115
3"
165
4"
265
6"
530
3

Table III
Number of Smaller Size Valves of Same Size to Meet Required Capacity at 15psi fall-off Pressure

Valve

Capacity Required for System (gpm)


30 40 50 60 70 80 90 100 110 120 130 140 150 160 175 200 225 250
275
300
400 450 500 550
600

Series LF25AUB-Z3 2-34" 2-1" 2-114" 2-112" 2-2" 2-2" 2-2" 2-2" 2-2"
Series LFU5B-Z3

2-34" 2-34" 2-1" 2-1" 2-14" 2-14" 2-112" 2-112" 2-2" 2-2" 2-2" 2-2" 2-2" 2-2"

Series LF223

2-12" 2-12" 2-34" 2-1" 2-1" 2-1" 2-114" 2-114" 2-114" 2-114" 2-114" 2-114" 2-112" 2-112" 2-112" 2-112" 2-2" 2-2" 2-212"

Series LFN223B
2-212" 2-212" 2-212" 2-3" 2-3"
Series LFN223F
2-3" 2-3"
Series LF127W
2-3" 2-4" 2-4"

Lead Free Transition


With the changeover to Lead Free in the United States that became effective January 4, 2014, Lead Free* pressure reducing valves
are required in many applications and/or settings. The Watts product line includes a full complement of top-quality, fully-tested
Lead Free* versions of our trusted and reliable water pressure reducing valves.
Standard Material Products (not Lead Free*) CONTAIN MORE THAN 0.25% LEAD.
Effective January 4, 2014, it is illegal to use this product in any plumbing system providing water for human consumption, such as
drinking or dishwashing, in the United States.
Before installing standard material product, consult your local water authority, building and plumbing codes.

End Connections
To facilitate installation and servicing of the regulator, Watts offers a variety of end fitting configurations, which include union fittings
(female threaded, solder, CPVC, PEX, and Quick-Connect end connections), flanged valves, water meter threads and special lay
lengths for water meter installations. Please refer to the valve model for specific availability of end connection options.
*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

Performance Curves
To match the valve characteristics to
system requirements Watts has provided
performance curves for each type and size
of valve giving the capacities of each with
reduced pressure fall-offs up to 25psi.

Where more than one type has adequate


capacity, the selection should consider
the advantages of the one that would
permit smaller pipe sizing and evaluate
the relative costs of each.

By the use of these charts, the most


suitable and economical valve can be
selected to satisfy the job requirements.

In solving capacity sizing problems, it is


suggested that Chart No. 1 is to be used
for a trial solution and the results then
compared with other types for final
evaluation of the selection.

The charts or curves for all types are plotted on a simple basis of rate of flow plotted against the reduced pressure fall-off.

The following examples are prepared to


enable a clear understanding of the use of
the charts in selecting valves for specific
applications or determining valve capacities
under specific pressure conditions.

In the left hand column, the reduced


pressure fall-off is listed up to 25psi.
Along the bottom, is listed capacity in
terms of gallons per minute flow.

Refer to specific charts on each page of


the guide or engineering sheets.

In the reduced pressure fall-off column,


the 0" represents the reduced pressure
setting of the valve set point when there
is no flow (reduced lock-up pressure). It
can be any setting within the adjustment
range of the valve. The figures below
0 show the pressure fall-off or change
the set pressure that results in the flow
shown by the curves of the various sizes
of valves.

EXAMPLE: Chart No. 1


Initial supply pressure: 100psi
Reduced no-flow (set) pressure: 50psi
Demand: 20 gallons per minute
Allowable reduced pressure fall-off:
15psi

On Chart No. 1, locate 20 gallons per


minute along the bottom line and move up
until it intersects a curve line. In this case, it
intersects the 34" size at approximately the
14psi reduced pressure fall-off line. Thus,
the 34" size provides the required capacity
at less than a 15psi fall-off and therefore,
will give excellent reduced flow pressure
service.
In this procedure, also note a 12" Model
LF223 in Chart No. 3 will meet this
capacity at a 15psi fall-off.
EXAMPLE: Chart No. 1
F
 ind the maximum capacity of a 1"
sized valve.
Find the 1" size curve and the intersection with the 20psi pressure fall-off
line. Moving down from this intersection, the a flow of 40 is found.
The valves maximum capacity is 40
gallons per minute.

With Watts water pressure reducing


valves, the difference between the initial
and reduced lock-up (no-flow) pressures
has a minor effect upon the valve capacity except when it is less than 50psi.
When this difference is less than 50psi,
the capacity of the valve is reduced and
some minor compensation must be made
in the sizing procedure. Therefore, either
deduct 20% from capacity shown or add
20% to capacity required.

Chart No. 1A Series LFU5B-Z3

Chart No. 1 Series LFU5B-Z3


Sizes 12", 34", 1"
4"

2"

138 20

1"

103 15
69 10
34 5

2"

112"

114"

138 20
103 15
69 10
34 5
0 0

0 0
0
0

Sizes 114", 112", 2"

kPa psi
172 25

Reduced Pressure Fall-off

Reduced Pressure Fall-off

kPa psi
172 25

10
38

20
76

Flow

30
114

40
152

50 gpm
190 lpm

10
38

30
114

50
190

70
266

Flow

90
342

110 gpm
418 lpm

Chart No. 2 Series LF25AUB-Z3


Sizes: 12", 34", 1", 114", 112", 2"

Reduced Pressure Drop

kPa psi
0 0

34 5

103 15

138 20
2"

172 25

4"

1"

114"

2"

112"

0 10 20 30 40 50 60 70 80 90
100
gpm
0 38 76 114 152 190 228 266 304 342
380
lpm

Flow

Chart No. 2A Series LFN223B


I.P. = 83psi, R.P. = 50psi Lockup

kPa psi
345 50

223
3"

Reduced Pressure Fall-Off

2 12"

(65mm)

276 40

70
60

207 30
138 20
121 17.5
103 15
86 12.5
69 10
52 7.5
34 5
17 2.5
0 0

(80mm)

80

50
40
30
20
10
0
0
5
10
15
40
80
120
160
200
240 320 400 480 560 640
720
gpm
PRESSURE
152
304
456
608
760
912 1216 1520 1824 2128 2432
2736
lpm FALL OFF - PSI

20

Flow

Chart No. 3 Series LF223

Chart No. 3A Series LF223

223

Sizes 12", 34", 1"

lpm gpm
304 80

266 70
70

2"

1"
4"

151 40
114 30

2"

76 20
20

150
570 150

112"

Flow

190 50
50

Flow

212"

200
760 200

227 60
60

100
379 100

114"

190 50
50

38 10
10
0 00

Sizes 114", 112223


", 2", 212"

lpm gpm
950 250

80

00

5
10
15
20 psi
5
10
15
20
0 34 69 103
138
kPa
PRESSURE FALL OFF - PSI

Pressure Drop

0 00

00

55
34

10
10

15
15

20
20

69
103
PRESSURE
FALL OFF138
- PSI

25
25
172

30 psi
30
207 kPa

Pressure Drop

223

200

150
100

Series LFU5B

Water Pressure Reducing Valves**


Sizes: 12" 2" (15 50mm)
LEAD FREE* Series LFU5B Water Pressure Reducing Valves are designed to

reduce incoming water pressure to a sensible level to protect


plumbing system components and reduce water consumption. The LFU5B features
Lead Free* construction to comply with Lead Free* installation requirements. This
series is suitable for water supply pressures up to 300psi (20.7 bar) and may be
adjusted from 25 75psi (172 517 kPa). The standard setting is 50psi (345 kPa).
All parts are quickly and easily serviceable without removing the valve from the line.
The LFU5Bs standard bypass feature*** permits the flow of water back through the
valve into the main when pressures, due to thermal expansion on the outlet side of
the valve, exceed the pressure in the main supply.

Sensitive spring and large


diaphragm area provide for
accurate pressure control
and wide range of adjustment

Body construction
Lead Free* Copper silicon alloy

High Temperature resisting diaphragm for hot or cold water


Suffix B bypass feature
Stainless steel seat
Large integral stainless
steel strainer screen easily
removed for cleaning

Disc holder removable


for replacement of disc
without dismantling the
valve - no special tools
required
Spring (not shown)
LP model only

Features

Models

Options

Standard construction includes Z3


sealed spring cage and stainless steel
corrosion resistant adjusting cage
screws for accessible outdoor or pit
installations

LFU5B-Z3 NPT threaded female


union inlet x NPT female
outlet w/built in thermal
expansion bypass
LFU5B-S-Z3 Solder union inlet x NPT
female outlet w/built in
thermal expansion bypass
LF5M3-Z6 Water meter threaded
connections and 712"
(190mm) lay length for
new or existing meter
box installations. For 58"
(16mm), 58" x 34" (16 x
20mm) or 34" (20mm)
meter setters or resetters
LFU5B-QC-Z3
Quick-Connect SingleUnion Inlet end

add Suffix:
G Gauge tapping
GG Gauge tapping and 160psi
(11.0 bar) gauge
HP High pressure range 75 100psi
(5.2 6.9 bar)
LP Low pressure range 10 35psi
(69 241 kPa)

Integral stainless steel strainer


Replaceable seat module
Lead Free* cast copper silicon alloy
body construction
Serviceable in line
Bypass feature controls thermal
expansion pressure (LFU5B-Z3)***
High temperature resistant reinforced
diaphragm for hot water

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
**A water saving test program concluded that reducing the supply pressure from 80-50psi (551-345 kPa) resulted in a water savings of 30%.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).*

Pressure Temperature

Standards

Temperature Range: 33F 160F



(0.5C 71C)
Maximum Working Pressure: 300psi

(20.7 bar)
Adjustable Reduced Pressure Range:

25 75psi (172 517 kPa)
Standard Reduced Pressure Setting:

50psi (345 kPa)

Meets requirements of ASSE Standard


1003; (ANSI A112.26.2); CSA Standard
B356; Southern Standard Plumbing
Code and listed by IAPMO.

Sizes 12", 34", 1" (15, 20, 25mm)

kPa psi
172 25

4"

2"

138 20

Reduced Pressure Fall-off

Reduced Pressure Fall-off

Capacity

1"

103 15
69 10
34 5
0 0

0
0

10
38

20
76

30
114

40
152

50 gpm
190 lpm

Sizes 114", 112", 2" (32, 40, 50mm)

kPa psi
172 25

114"

138 20

2"

112"

103 15
69 10
34 5
0 0
10
38

30
114

50
190

70
266

90
342

110 gpm
418 lpm

Dimensions Weights

A - LFU5B-Z3
A1 - LFU5B-S-Z3
ET - NPT Engagement for tight joint
ES - Female sweat socket depth
EQC
- Quick-Connect

Et

F*(Max)
C (Max)

FQC

Es

D
EQC

MODEL

SIZE (DN)

DIMENSIONS
A

in.

mm

in.

A1
mm

2
15 558 142.8
3
4
20 6316 157.1
1
25 658 168.2
114 32 71516 190.5
112 40 9716 239.7
2
50 1078 276.2

Dimension includes optional gauge


LFU5B-Z3

A
A1

in.

mm

in.

mm

in.

mm

in.

512
614
634
71116
934
1112

139.7
158.7
171.4
195.2
247.6
292.1

578
678
738
838
938
1214

149.2
174.6
187.3
212.7
238.1
311.1

158
178
2
214
278
314

41.2
47.6
50.8
57.1
73
82.5

3116
312
4
412
434
6

mm

weight

Et
in. mm

77.7 716
88.9 12
101.6 916
113.3 58
120.6 58
152.4 58

11.1
12.7
14.2
15.8
15.8
15.8

Es

EQC

in.

mm

12.7 1716 36 112


19 1916 40 11116
22.2 11116 43 134
25.4

28.5

34.9

2
3
4
7
8
1
118
138

in.

FQC
mm

in.

For additional information, reference literature ES-LFU5B.

mm

in.

38
42
45

1014
1112
1218
1338
15
1814

lbs.

kgs.

260.3 4
292.1 5
307.9 6
339.7 9.4
381.0 14.4
463.5 23

mm

1.8
2.3
2.7
4.3
6.5

10.4

Series LF25AUB-Z3

Water Pressure Reducing Valves**


Sizes: 12" 2" (15 50mm)
LEAD FREE* Series LF25AUB-Z3 Water Pressure Reducing Valves are

designed to reduce incoming water pressure to a sensible level


to protect plumbing system components and reduce water consumption. This series
is suitable for water supply pressures up to 300psi (20.7 bar) and may be adjusted
from 25 75psi (172 517 kPa). The LF25AUB-Z3 features Lead Free* construction
to comply with Lead Free* installation requirements. The standard setting is 50psi (345
kPa). All parts are quickly and easily serviceable without removing the valve from the
line. The standard bypass feature*** permits the flow of water back through the valve
into the main when pressures, due to thermal expansion on the outlet side of the valve,
exceed the pressure in the main supply.

Bypass valve assembly


for 114" 2" sizes

EPDM diaphragm

Union inlet connection


Bypass for 12" 1" sizes
Integral stainless
steel strainer

Replaceable seat module

Features

Models

Options

Standard construction includes Z3


sealed spring cage and stainless steel
corrosion resistant adjusting & cage
screws for accessible outdoor or pit
installations

LF25AUB-Z3 NPT threaded female


union inlet x NPT female
outlet
LF25AUB-S-Z3 Solder union inlet x NPT
female outlet
LF25AUB-DU-Z3 Double Union NPT
threaded union female
inlet and outlet
LF25AUB-S-DU-Z3
Double Union Solder
union inlet and outlet
LF25AUB-DU-THDxPEX-Z3
Double Union NPT
threaded female inlet
and PEX union outlet
LF25AUB-DU-LF-Z3
Double union body less
fittings (34", 1", 11/4")
LF25AUB-QC-Z3 Single Union QuickConnect union inlet (12",
3
4", 1")
LF25AUB-DU-QC-Z3
Double Union QuickConnect inlet and outlet
(12", 34", 1")

add Suffix:

Union inlet connection


Integral stainless steel strainer
Replaceable seat module
Lead Free* cast copper silicon alloy
construction
Serviceable in line
Bypass feature controls thermal
expansion pressure***
High temperature resistant reinforced
diaphragm for hot water

GG Gauge tapping, 18" (3mm)


GG Gauge tapping and 160psi
(11 bar) gauge
HP High pressure range 75125psi
(5.2 8.6 bar)
LP Low pressure range 1035psi
(69 241 kPa)
Z7 400psi (27.6 bar) initial pressure,
1
2" (20mm) models only

Pressure Temperature
Temperature Range: 33F 160F

(0.5C 71C)
Maximum Working Pressure: 300psi

(20.7 bar)
Adjustable Reduced Pressure Range:

2575psi (172 517 kPa)
Standard Reduced Pressure Setting:

50psi (345 kPa)

Standards
Meets requirements of ASSE Standard
1003: ANSI A112.26.2: CSA Standard
B356; Southern Standard Plumbing
Code and listed by IAPMO.
Military Standard MIL-V-18146B Type I.

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
**A water saving test program concluded that reducing the supply pressure from 80-50psi (551-345 kPa) resulted in a water savings of 30%.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).

Currently not available with G or GG options.

10

Capacity
Sizes: 

1
2", 34", 1", 114", 112", 2"
(15, 20, 25, 32, 40, 50mm)

kPa psi
0 0

Reduced Pressure Drop

34 5

69 10

103 15
138 20
172 25

2"

1"

4"

114"

2"

112"

0 10 20 30 40 50 60 70 80 90
100
gpm
0 38 76 114 152 190 228 266 304 342
380
lpm

Flow

Dimensions Weights
A - LF25AUB-Z3
A1 - LF25AUB-S-Z3
A2 - LF25AUB-DU-LF-Z3
B - LF25AUB-DU-Z3
B1 - LF25AUB-S-DU-Z3
B2 - LF25AUB-DU-THDxPEX-Z3
ET - NPT Engagement for tight joint
ES - Female sweat socket depth
EP - PEX end connection
FQC - Quick-Connect union
ET

F* (Max)

FQC

EP

ES

A2

C (Max)

EQC

B, B1, B2

SIZE (DN)

dimensions
A

A1

A2

B1

B2

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

15
20
25
32
40
50

538
5516
6
834
834
914

137
135
152
222
222
235

5516
512
614
81516
9
10

135
140
159
227
229
254

5316
514
578
814
814
834

132
133
149
210
210
222

6716
612
738
1034
1034
11516

164
165
187
273
273
287

638
678
71316
11
11316
121116

162
175
198
279
284
322

634
71116

171
195

7
7
8
9
912
1114

178
178
203
229
241
286

2
3
4
1
114
112
2

SIZE (DN)

DImensions

D
in.

F*
mm

in.

112
38
9716
38
9716
112
44
10716
134
54
11716
218
60
111516
238
83
131116
314
* Dimension includes optional gauge

A, A1

ET

Weight
ES

EP

FQC

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

240
240
266
291
304
348

318
318
358
358
4116
434

79
79
92
92
103
121

13
13
16
16
16
16

13
19
23
25
28
34

5
8
13
16

16
21

112
11116
134

38
42
45

3.5
3.5
6.5
10
10
15

1.6
1.6
3.0
4.5
4.5
6.8

2
1
2
5
8
5
8
5
8
5
8

2
3
4
15
16
1
1116
1516

For additional information, reference literature ES-LF25AUB.

11

Series LFX65B

Water Pressure Reducing Valves**


Sizes: 12" 2" (15 50mm)
LEAD FREE* Series LFX65B Water Pressure Reducing Valves are designed

to reduce incoming water pressure to a sensible level to protect


plumbing system components and reduce water consumption.
The LFX65B features Lead Free* construction to comply with Lead Free* installation
requirements.
The LFX65B is a cartridge style regulator and is orderable three ways: As a complete,
ready-to-install regulator, or as a separate Rough-in Kit consisting of a Lead Free* cast
copper silicon alloy body with integral strainer, or as a separate Cartridge Assembly.
The LFX65B delivers superior flow performance with low fall off pressure while reducing flow noise with its engineered seat design. The LFX65B is a 100 percent balanced
valve, as inlet pressures fluctuate, reduced pressure does not.
The LFX65B incorporates control valve style stem and disc guidance for accuracy
and longevity. It is available with interchangeable union tailpiece kits in standard-sized
solder and threaded tailpieces for Quick-Connect, PEX and CPVC options. The X65B
Cartridge Assemblies are available in standard pressure range of 20 - 80psi (138 552
kPa), preset at the factory to 50psi (345 kPa) or high-pressure range (HP) of 50 -150psi
(345 1034 kPa) preset at the factory to 100psi (6.9 bar). The standard bypass feature*** permits the flow of water back through the valve into the main when pressures,
due to thermal expansion on the outlet side of the valve, exceed the pressure in the
main supply.

Features

Models

Cartridge Style valve enables quick and


easy installation or service in-line.

LFX65B NPT threaded female


inlet x NPT female
outlet
LFX65BU NPT threaded union
inlet x NPT female
outlet
LFX65BUS Solder union inlet x
NPT female outlet
LFX65BDU Double Union NPT
threaded union female
inlet and outlet
LFX65BDUS Double Union Solder
union inlet and outlet
LFX65BU-QC Single Union QuickConnect union inlet x
NPT female outlet*
LFX65BDU-QC Double Union
Quick-Connect union
inlet and outlet
LFX65BDU-CPVC Double Union - CPVC
union inlet x CPVC
union outlet
LFX65BDU-PEX Double Union - PEX
union inlet x PEX
union outlet

Greater flow performance with lower


fall off pressure for consistent operation
100% balanced valve, unique to Watts,
provides reliable flow performance
Full size range available rated to 400psi
to meet your commercial and residential applications
Cartridge Assemblies available in standard and high-pressure (HP) models
Bypass feature in Cartridge Assembly
controls thermal expansion pressure***.
Standard construction includes sealed
spring cage and corrosion resistant
adjusting and cage screws for accessible outdoor or pit installations
High performance thermoplastic integral seat cartridge
Union connection and tailpiece kits for
solder, Quick-Connect, PEX, CPVC
and threaded to meet your commercial
and residential applications.
High temperature resistant reinforced
diaphragm for hot water

For sizes 1/2", 3/4", 1 (15, 20, 25mm) only


For sizes 3/4", 1" (20, 25mm) only

Adjusting Screw
Lock Nut
Lock Seal
Spring Washer
Spring
Spring Cage
Stem Nut
Stem Lock Washer
Diaphragm Pressure Plate
Diaphragm
Base Plate
Valve Stem
Stem O-ring
Strainer
Seat Cartridge
Disc
Disc Holder
Valve Body
Gauge Port Plug

Materials
Body: Lead Free* cast copper silicon
alloy
Seat: Thermoplastic cartridge
Integral Strainer: Stainless steel
Diaphragm:
Reinforced EPDM
Valve Disc:
EPDM

Pressure Temperature
Temperature Range: 33F 180F

(0.5C 82C)
Maximum Working Pressure: 400psi

(27.6 bar)
Adjustable Reduced Pressure Range:

2080psi (138 552 kPa)
Standard Reduced Pressure Setting:

50psi (345 kPa)
HP Reduced Pressure Range:
50-150psi (345 1034 kPa)
HP Reduced Pressure Setting: 100psi

(6.9 bar)

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
**A water saving test program concluded that reducing the supply pressure from 80-50psi (551-345 kPa) resulted in a water savings of 30%.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).

12

Options
add Suffix:
G
Gauge tapping, 14" (8mm)
GG Gauge tapping and 160psi
(11.0 bar) gauge
HP High pressure range 50150psi
(3.4 10.3 bar)
LP Low pressure range 10-15 psi

Standards
Certified to ASSE Standard 1003, and
listed by ASSE and IAMPO.

Capacity
kPa psi

Sizes 12", 34", 1" (15, 20, 25mm)

14 2
28 4

Reduced Pressure Drop

Reduced Pressure Drop

0 0

(25mm)

41 6
55 8
69 10

(20mm)

(15mm)

83 12
96 14
110 16
124 18

138 20

0 5 10 15 20 25
30
gpm

0 79 38 57 76 95
114
lpm

kPa psi
Sizes 114", 112", 2" (32, 40, 50mm)
0 0
14 2
28 4
(50mm)
41 6
55 8
69 10
(40mm)
83 12
(32mm)
96 14
110 16
124 18
138 20
0
20
40
60
80
100 120 140 gpm
0 76 151 227 303 379 454 530
lpm

Dimensions Weights
D

A
E

C
F

SIZE (DN)

dimensions
A

in.

mm

in.

mm

15
20
25
32
40
50

3
318
3916
4516
512
512

76.7
79.8
90.4
110.2
140.2
140.2

2
3
4
1
114
112
2

B (MAX) STD
in.
mm

5716
5716
6316
61516
1134
1134

137.7
137.7
157.2
176.0
297.9
297.9

B (MAX) HP
in.
mm

61116
61116
71416
91316
1634
1634

169.9
169.9
199.9
248.9
426.0
426.0

C
in.

mm

1516
1516
138
1916
178
178

32.8
32.8
34.5
39.40
47.50
47.50

D (DIA)
in.
mm

2716
2716
234
314
4916
4916

61.2
61.2
70.6
81.8
115.8
115.8

E (Threaded)
in.
mm

31116
334
41516
558
61316
61316

93.0
96.0
110.2
142.7
142.7
173.5

WEIGHTS
E (Sweat)
in.
mm

358
4
4916
538
61116
61516

E (QC)
in.
mm

91.9 412 115


101.1 41316 122
116.1 5516 135
136.9

169.9

176.5

F (Threaded)
in.
mm

4516
4716
518
678
8116
818

109.2
112.3
130.0
175.3
205.2
206.8

F (Sweat)
in.
mm

414
41316
5916
6716
778
838

For additional information, reference literature ES-LFX65B.

F (QC)
in.
mm

107.2 6
122.4 612
141.7 7116
163.6
199.6
212.9

153
165
179

lbs.

kgs.

1.43
1.52
2.22
3.61
9.27
9.59

0.65
0.69
1.01
1.64
4.20
4.35

13

Series LFN45B-M1

Water Pressure Reducing Valves**


Sizes: 34" 1" (20 25mm)
LEAD FREE* Series LFN45B-M1 Water Pressure Reducing Valves are

designed to reduce incoming water pressure to a sensible


level to protect plumbing system components and reduce water consumption. The
LFN45B features Lead Free* construction to comply with Lead Free* installation
requirements. This series is suitable for water supply pressures up to 400psi (27.6
bar) and may be adjusted from 25 75psi (172 517 kPa). The standard setting
is 50psi (345 kPa). All parts are quickly and easily serviceable without removing the
valve from the line. The standard bypass feature*** permits the flow of water back
through the valve into the main when pressures, due to thermal expansion on the
outlet side of the valve, exceed the pressure in the main supply.

Reinforced diaphragm
Integral stainless
steel strainer

Threaded, solder
PEX or CPVC ends

Thermal expansion bypass

Thermoplastic seat

Features

Models

Options

Double union inlet & outlet connections


(option DU)

LFN45B-M1 NPT threaded female


inlet x NPT female outlet
LFN45BU-M1 NPT threaded union
inlet x NPT female outlet
LFN45BU-S-M1 Solder union inlet x
NPT female outlet
LFN45BU-QC-M1 Single Union QC
union inlet
LFN45BDU-M1 Double Union NPT
threaded union female
inlet and outlet
LFN45BDU-S-M1

Double Union Solder

union inlet and outlet
LFN45BDU-PEX-M1
Double Union PEX
union inlet and outlet
(34" and 1" only)
LFN45BDU-CPVC-M1
Double Union CPVC
union inlet and outlet
(34" and 1" only)
LFN45BDU-QC-M1
Double Union QC
union inlet and outlet
(34" and 1" only)

add Suffix:
G
Gauge tapping
GG Gauge tapping and 160psi
(11.0 bar) gauge

Integral stainless steel strainer


Thermoplastic seat & cage
Lead Free* cast copper silicon alloy
body construction
Serviceable in line
Bypass feature controls thermal
expansion pressure***
Sealed spring cage on all models for
accessible outdoor or pit installations

Pressure Temperature
Temperature Range: 33F 180F

(0.5C 82C)
Maximum Working Pressure: 400psi

(27.6 bar)
Adjustable Reduced Pressure Range:

25 75psi (172 517 kpa)
Standard Reduced Pressure Setting:

50psi (345 kpa)

Standards
Meets requirements of ASSE Standard
1003; (ANSI A112.26.2) and
CSA Standard B356. Certified by NSF
to ANSI/NSF Standard 61 Annex
G. Listed by IAPMO and City of Los
Angeles.

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
**A water saving test program concluded that reducing the supply pressure from 80-50psi (551-345 kPa) resulted in a water savings of 30%.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).

14

Capacity
kPa psi

Pressure Drop

0 0
34.5

68.9

10

103.4

15

137.8

20

172.3

25
0 10 20 30
40
gpm
0
37.3
75.7
113.6 151.4
lpm

Flow

FNPT

Dimensions Weights
ENPT
FSWEAT

ESWEAT
C

FPEX

FEMALE NPT THREAD


BOTH ENDS OF BODY

EPEX
FCPVC
D

ECPVC

A
A+E
A+E+E

FQC

ABOVE VALVE SHOWN WITH SINGLE NPT UNION CONNECTION ON INLET


VALVES MAY BE ORDERED WITH 0,1,OR 2 UNION CONNECTIONS USING ANY
COMBINATION OF NPT, SOLDER, PEX OR CPVC CONNECTIONS REQUIRED
F" DIMENSIONS ARE APPROXIMATE ENGAGEMENT LENGTHS.

EQC

Size (DN)

Dimensions
A

in.

mm

20
25

4
1

in.

C
mm

in.

D
mm

in.

ENPT
mm in. mm

3716 88 4916 116 11116 43


418 105 4916 116 11116 43

8
3
4

16
20

ESWEAT
in. mm
7

EPEX
in. mm

ECPVC
in. mm

EQC
in. mm

8 21 1516 24 1316 21 1916 40


1 26 118 29 1116 26 11116 43

WEIGHT
FNPT
in. mm

FSWEAT
in. mm

FPEX
in. mm

FCPVC
in. mm

16 14
11
16 17

4 19
15
16 23

8 16
13
16 21

FQC
in.

G
mm

in.

mm lbs. kgs.

4 18 11116 42 214 57
15
16 23 134 45 214 57

For additional information, reference literature ES-LFN45B.

2 .91
3 1.36

15

Series LFN45B - EZ**


Water Pressure Reducing Valves
Sizes: 34" 1" (20 25mm)
Series LFN45B-EZ Water Pressure Reducing Valves are

LEAD FREE* designed to reduce incoming water pressure to a sensible

level to protect plumbing system components and reduce water consumption.


This series is suitable for water supply pressures up to 400psi (27.6 bar) and may
be adjusted from 25 75psi (172 517 kPa). The standard setting is 50psi (345
kPa). All parts are quickly and easily serviceable without removing the valve from
the line. The standard bypass feature*** permits the flow of water back through the
valve into the main when pressures, due to thermal expansion on the outlet side of
the valve, exceed the pressure in the main supply. The LFN45-B-EZ features Lead
Free* construction to comply with Lead Free* installation requirements.

Reinforced
Diaphragm
Threaded, Solder,
PEX or CPVC ends

Integral Stainless
Steel Strainer

Thermal Expansion
Bypass

Thermoplastic Seat

Features

Models

Options

F
 actory calibrated outlet pressure
adjustment

LFN45B-EZ-M1 NPT threaded female


inlet x NPT female
outlet
LFN45BU-EZ-M1 NPT threaded union
inlet x NPT female
outlet
LFN45BU-EZ-S-M1
Solder union inlet x
NPT female outlet
LFN45BDU-EZ-M1
Double Union NPT
threaded union female
inlet and outlet
LFN45BDU-EZ-S-M1
Double Union Solder
union inlet and outlet
LFN45BDU-EZ-PEX-M1
Double Union PEX
union inlet and outlet
LFN45BDU-EZ-CPVC-M1
Double Union CPVC
union inlet and outlet

add Suffix:
G
Gauge tapping
GG Gauge tapping and 160psi (11 bar)
gauge

Easily adjustable pressure setting


D
 ouble union inlet & outlet connections
(option DU)
Integral stainless steel strainer
Thermoplastic cage & seat
L
 ead Free* copper silicon alloy body
construction
Serviceable in line
B
 ypass feature controls thermal expansion pressure***

Materials
Body: Lead Free* Cast Copper Silicon
Alloy
Seat: Thermoplastic
Cage: Thermoplastic
Integral Strainer: Stainless steel
Diaphragm:
Reinforced EPDM
Valve Disc:
Elastomer

Pressure Temperature
Temperature Range: 33F 180F

(0.5C 82C)
Maximum Working Pressure: 400psi

(27.6 bar)
Adjustable Reduced Pressure Range:

25-75psi (172 - 517kPa)
Standard Reduced Pressure Setting:

50psi (345kPa)

Standards
Meets requirements of ASSE Standard
1003; (ANSI A112.26.2); CSA Standard
B356; and listed by IAPMO.

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
**A water saving test program concluded that reducing the supply pressure from 80-50psi (551-345 kPa) resulted in a water savings of 30%.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).

16

Capacity
kPa psi

Pressure Drop

0 0
34.5

68.9

10

103.4

15

137.8

20

172.3

25
0 10 20 30
40
gpm
0
37.3
75.7
113.6 151.4
lpm

Flow

Dimensions Weights
FNPT

ENPT
FSWEAT

C
FEMALE NPT THREAD
BOTH ENDS OF BODY

ESWEAT
FPEX
D
EPEX
A
A+E
A+E+E

FCPVC

ABOVE VALVE SHOWN WITH SINGLE NPT UNION CONNECTION ON INLET


VALVES MAY BE ORDERED WITH 0,1,OR 2 UNION CONNECTIONS USING ANY
COMBINATION OF NPT, SOLDER, PEX OR CPVC CONNECTIONS REQUIRED

ECPVC

F" DIMENSIONS ARE APPROXIMATE ENGAGEMENT LENGTHS.

Size (DN)

DIMENSIONS
A

in.

mm

20
25

4
1

in.

C
mm

in.

D
mm

in.

mm

3716 88 438 111 11116 43


418 105 438 111 11116 43

ENPT
in. mm

ESWEAT
in. mm

8
3
4

16
20

8
1

21
26

EPEX
in. mm
15

16
118

24
29

WEIGHT

ECPVC
in. mm
13

16
1116

21
26

FNPT
in. mm

FSWEAT
in. mm

FPEX
in. mm

FCPVC
in. mm

16
11
16

14
17

4
15
16

19
23

8
13
16

16
21

For additional information, reference literature ES-LFN45B-EZ.

4
15
16

18
23

G
in.

mm

lbs

kg

214
214

57
57

1.75
2

.79
.91

17

Series LF223, LF223S

High Capacity Water Pressure Reducing Valves**


Available with or without
separate strainer

Sizes: 12" 212" (15 65mm)


LEAD FREE* Series LF223 and LF223S High Capacity Water Pressure

Reducing Valves are designed to reduce incoming water pressure to a sensible level to protect plumbing system components and reduce water
consumption. The LF223/LF223S features Lead Free* construction to comply with
Lead Free* installation requirements. This series is suitable for water supply pressures
up to 300psi (20.7 bar) and may be adjusted from 25 75psi (172 517 kPa). The
standard setting is 50psi (345 kPa). Series LF223 features an enlarged diaphragm,
spring cage and seat orifice for high capacity performance. Series LF223S has the
same options as the LF223, except it is furnished with a strainer. All parts are quickly
and easily serviceable without removing the valve from the line. The optional bypass
feature*** permits the flow of water back through the valve into the main when pressures, due to thermal expansion on the outlet side of the valve, exceed the pressure
in the main supply.

Sealed spring cage

High temperatureresisting diaphragm


for hot or cold
water

Sensitive spring and large


diaphragm area for accurate
pressure control
Lead Free* brass construction
1
2" 2"
Replaceable stainless seat
Disc holder removable for
replacement of disc without
dismantling the valve - no
special tools required

Light Stainless steel


perforated strainer
screen

Features

Models

Options

Enlarged diaphragm, spring cage and


seat orifice for super capacity performance

LF223 NPT threaded female inlet x


NPT threaded female outlet
LF223-S 
NPT threaded female inlet with
strainer x NPT threaded female
outlet
For 212" 3" (65 80mm) bronze
threaded valves, refer to literature
ES-LFN223B.
For 3" (80mm) flanged connections, refer
to literature ES-LFN223F.

add Suffix:
B Built in bypass feature
LP Low pressure range 10-35psi
(69 241 kPa)
HP High pressure range, reduced
range shown below:

Lead Free* brass body construction


(except 212" (65mm) which is iron)
Serviceable in line
Series LF223S furnished with separate
strainer
Optional bypass feature controls thermal expansion pressure***
Sealed spring cage on all models for
accessible outdoor or pit

Reduced Pressure Range - Suffix HP


Size

Range

in.

mm

psi

bar

15
20
25
32
40
50
65

50-145
50-145
50-145
50-120
50-95
50-95
50-95

3.52-10.19
3.52-10.19
3.52-10.19
3.52-8.44
3.52-6.68
3.52-6.68
3.52-6.68

2
3
4
1
114
112
2
212

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
**A water saving test program concluded that reducing the supply pressure from 80-50psi (551-345 kPa) resulted in a water savings of 30%.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).

18

223
80

Materials

Pressure Temperature

Body: 12" 2" (15 50mm) Lead Free*


Brass 212" (65mm) Iron
Seat: Replaceable stainless steel
Strainer Screen: Stainless steel (Model
LF223S)
Diaphragm:
Reinforced Buna-N
Valve Disc:
EPDM

Temperature Range: 33F 160F 60



(0.5C 71C) 50
Maximum Working Pressure: 300psi 40

(20.7 bar) 30
Adjustable Reduced Pressure Range:

25-75psi (172 517 kPa)20
Standard Reduced Pressure Setting:10

50psi (345 kPa) 0

Standards

70

2" 2"
(15 50mm)
meets requirements of ASSE Standard
1003; (ANSI A112.26); CSA Standard
B356; Southern Standard Plumbing
Code, Military Standard MIL-V-18146B
and listed by IAPMO.

10

15

20

PRESSURE FALL OFF - PSI

Capacity
223

Sizes 12", 34", 1" (15, 20, 25mm)

lpm gpm
304 80
80
266 70
70

2"

1"

190 50
50

150
570 150

4"

151 40
114 30

112"

Flow

Flow

212"

200
760 200

227 60
60

100
379 100

2"

114"

76 20
20

190 50
50

38 10
10
0 00

Sizes 114", 112", 2", 212223


" (32, 40, 50, 65mm)

lpm gpm
950 250

0 00

00

5
10
15
20 psi
5
10
15
20
0 34 69 103
138
kPa
PRESSURE FALL OFF - PSI

00

55
34

Pressure Drop

10
10

15
15

20
20

69
103
PRESSURE
FALL OFF138
- PSI

25
25
172

30 psi
30
207 kPa

Pressure Drop

As

223

C
200
150

Dimensions Weights
D

100

N
50
0
0

10

15

20

25

30

PRESSURE FALL OFF - PSI

Size (DN)
in.

mm

15
20
25
32
40
50
65

414
414
434
5
634
8
9

2
3
4
1
114
112
2
212

Dimensions
A (LF223)
in.
mm

108
108
121
127
171
203
229

As (LF223S)
in.
mm

9
9
101516
111516
1434
1634
2018

229
229
262
287
375
425
511

Weight

in.

mm

in.

mm

614
614
612
634
978
1034
1034

159
159
165
172
251
273
273

2
2
218
234
234
338
338

50
50
54
70
70
86
86

N (LF223S)
in.
mm

212
212
21516
3
3716
4
5

64
64
75
76
87
102
127

LF223

LF223S

lbs.

kgs.

lbs.

kgs.

4.5
5
7
9
19.5
30
32.5

2.0
2.3
3.2
4.1
8.8
13.6
14.8

6
6.5
9.5
12
23.5
37.5
59

2.7
2.9
4.3
5.4
10.7
17.0
26.8

For additional information, reference literature ES-LF223.

19

Series LFN223B, LFN223BS

Super Capacity Water Pressure Reducing Valves**


Sizes: 212" 3" (65 80mm)
LEAD FREE* Series LFN223B and LFN223BS Super Capacity Water

Pressure Reducing Valves are designed to reduce incoming


water pressure to a sensible level to protect plumbing system components and
reduce water consumption. The LFN223B/LFN223BS features Lead Free* construction to comply with Lead Free* installation requirements. This series is suitable
for water supply pressures up to 300psi (20.7 bar) and may be adjusted from 25
75psi (172 517 kPa). The standard setting is 50psi (345 kPa). Series LFN223B
features an enlarged diaphragm, spring cage and seat orifice for super capacity
performance. Series LFN223BS has the same options as the LFN223B, except it
is furnished with a Lead Free* strainer. All parts are quickly and easily serviceable
without removing the valve from the line. The standard bypass feature*** permits
the flow of water back through the valve into the main when pressures, due to
thermal expansion on the outlet side of the valve, exceed the pressure in the main
supply.

Sensitive spring and large


diaphragm area for accurate
pressure control
Bypass

Sealed spring cage


Lead Free*body
construction

Large stainless steel


perforated strainer screen

Disc holder removable for replacement of


disc without dismantling the valve
no special tools required.

Renewable
stainless steel
alloy seat

Features

Models

Options

Enlarged diaphragm, spring cage


and seat orifice for super capacity
performance

2 2" LFN223M2-B

NPT threaded female inlet
x NPT threaded female
outlet
3" LFN223M1-B
NPT threaded female inlet x
NPT threaded female outlet
212" LFN223M2-BS
NPT threaded female inlet
with strainer x NPT threaded
female outlet
3" LFN223M1-BS
NPT threaded female inlet
with strainer x NPT threaded
female outlet
For 12" 212" threaded connections, refer
to literature ES-LF223.
For 3" flanged connections, refer to literature ES-LF223F.

add Suffix:
HP H
 igh pressure range 75 125psi
(172 862 kPa)
212" HP, LP, G and GG options
3" HP option

Lead Free* cast copper silicon alloy


body construction
Serviceable in line
Series LFN223BS furnished with
separate Lead Free* strainer
Standard bypass feature controls
thermal expansion pressure***
Sealed spring cage on all models for
accessible outdoor or pit installations

Materials
Body: Lead Free* cast copper silicon
alloy
Seat: Replaceable stainless steel alloy
Strainer Screen: Stainless steel (model
LFN223S)
Diaphragm:
Reinforced Buna-N
Valve Disc:
EPDM

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
**A water saving test program concluded that reducing the supply pressure from 80-50psi (551-345 kPa) resulted in a water savings of 30%.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).

20

Pressure Temperature

Standards

Temperature Range: 33F 160F



(0.5C 71C)
Maximum Working Pressure: 300psi

(20.7 bar)
Adjustable Reduced Pressure Range:

25 75psi (172 517 kPa)
Standard Reduced Pressure Setting:

50psi (345 kPa)

Both 212" and 3"


are listed to ASSE
1003 through IAPMO (UPC).
The 212" is also listed to ASSE 1003
through ASSE.
Both 212" and 3" are listed to NSF 61-G

Capacity
kPa psi

Reduced Pressure Fall-Off

345 50
3"

2 12"

276 40

207 30

138 20
121 17.5
103 15
86 12.5
69 10
52 7.5
34 5
17 2.5
0 0
40
80
120
160
200
240 320 400 480 560 640 720
gpm
152
304
456
608
760
912 1216 1520 1824 2128 2432
2736
lpm

Flow

Dimensions Weights
A

N
L

Size (DN)

Dimensions (APPROX.)

In.

mm

212
3

65
80

A (LFN223BS)
In.
mm

17
2034

432
527

Weight

In.

mm

In.

mm

In.

mm

N (LFN223BS)
In.
mm

1034
1234

273
324

278
418

73
105

778
1012

200
267

5
634

127
172

LFN223B
lbs.
kgs.

LFN223BS
lbs.
kgs.

30
71

44
95

For additional information, reference literature ES-LFN223B.

13.6
32.2

20.0
43.0

21

Series LFN223F, LFN223FS

Flanged Super Capacity Water Pressure Reducing Valves**


Size: 3" (80mm)
LEAD FREE* Series LFN223F and LFN223FS Super Capacity Water Pressure

Reducing Valves are designed to reduce incoming water pressure to a sensible level to protect plumbing system components and reduce water
consumption. This series is suitable for water supply pressures up to 175psi (12.1
bar) and may be adjusted from 25 75psi (172 517 kPa). The standard setting is
50psi (345 kPa). Series LFN223F features an enlarged diaphragm, spring cage and
seat orifice for super capacity performance. These valves also contain a semibalanced
piston feature to assure rapid response to reduced pressure changes as well as to
provide maximum flow with minor pressure drop. Series LFN223FS has the same
options as the LFN223F, except it is furnished with a strainer. All parts are quickly and
easily serviceable without removing the valve from the line.

Sensitive spring and large


diaphragm are for accurate
pressure control.

Sealed cage

High temperatureresisting nylonreinforced diaphragm.

Iron body of
valve is coated
with special
corrosion
preventative
type of cold
galvanizing.

Renewable
stainless
steel seat

All parts easily


serviceable
for quick
maintenance.

4" (20mm) tapping for auxiliary regulator

Features

Models

Pressure Temperature

Enlarged diaphragm, spring cage and


seat orifice for super capacity performance
Iron body construction
Stainless steel piston
Series LFN223FS furnished with separate strainer
Sealed spring cage on all models for
accessible outdoor or pit installations

LFN223F Flanged inlet x Flanged outlet


LFN223FS Flanged inlet x Flanged outlet
with strainer

Temperature Range: 33F 160F



(0.5C 71C)
Maximum Working Pressure: 175psi

(12.1 bar)
Adjustable Reduced Pressure Range:

25 75psi (172 517 kPa)
Standard Reduced Pressure Setting:

50psi (345 kPa)

Materials
Body: Iron coated with corrosionresistant cold galvanizing
Seat: Replaceable stainless steel
Diaphragm: Reinforced Buna-N
Disc: EPDM
Piston: Stainless steel

Options
add Suffix:
3
WR 
4" (20mm) Model LF223 auxiliary
regulator (piping not included)
S Strainer
(See ES-77F-DI-125 for details)

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
**A water saving test program concluded that reducing the supply pressure from 80-50psi (551-345 kPa) resulted in a water savings of 30%.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).

22

Option WR
3" (80mm) LFN223F
Reduced Pressure

High Pressure

4" (20mm) LF223 regulator


to handle low demands.
Set 10psi (68 kPa)
higher than LFN223F.

Piping not provided

Capacity

Reduced Pressure Fall-Off

kPa psi
138 20

103 15

69 10

34 5

0 0

40 80 120 160 200
gpm

152 304 456 608 760
lpm

Flow

Dimensions Weights

D
N

L
A
AS

Model NO.

Size (Dn)

Dimensions
A

LFN223F
LFN223FS

AS

Weight

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

3
3

80
80

1212
1212

318
318

2258

575

1412
1412

368
368

334
334

95
95

712
712

191
191

1018

257

178

86
120

39
54

For additional information, reference literature ES-LFN223F.

23

Model LF127W and LFF127W


High Capacity Water Pressure Reducing Valve
Sizes: 3" 4" (80 100mm)
LEAD FREE* Model LF127W and LFF127W High

Capacity Water Pressure Reducing Valves


are designed to reduce incoming water pressure to a sensible
level to protect plumbing system components and reduce water
consumption. The LF127W and LFF127W are remote control
type regulators ideal for commercial and industrial applications
where a regulator must reach full capacity with a minor drop in
reduced pressure. These models are also suitable for applications
where close pressure regulation is required through extensive
volume demand. These models are suitable for water supply
pressures up to 175psi (12.1 bar) and may be adjusted from 25
100psi (172 690 kPa). All parts are quickly and easily serviceable.
The LF127W and LFF127W feature Lead Free* construction to
comply with Lead Free* installation requirements.

Equalizer Line
(not furnished)

3" (80mm) LF127W


with Threaded Ends

4" (100mm) LFF127W


with Flanged Ends

6", 8" or 10"


(150, 178,
or 200mm)
depending
upon reduced
pressure range.
High temperatureresisting diaphragm

Diaphragm chamber is
easily changed by the removal of two cap screws

Requirements of various
pressure conditions
can be quickly met by
interchanging the various
sizes of diaphragm
chambers - 6", 8", 10"
(150, 178, 200mm) as well
as by interchanging spring

Stainless steel stem

Valve disc can be


quickly replaced

Tapping provided in low


pressure side of body to permit convenient, economical
attachment of equalizer line

Replaceable stainless steel seat

Features

Pressure Temperature

Options (4" F127W only)

Lead Free* body construction

Temperature Range: 33F 160F



(0.5C 71C)
Maximum Working Pressure: 175psi

(12.1 bar)
Adjustable Reduced Pressure Range:

25 100psi (17 690 kPa))

add Suffix:

Replaceable stainless steel seat


Outstanding maintenance features
Close control of reduced pressure
High temperature-resisting diaphragm
Interchangeable diaphragm chamber

Materials
Body: LF127W: Lead Free* cast copper silicon alloy
LFF127W: Iron
Seat: Replaceable stainless steel
Stem: Stainless steel

3
WR 
4" (20mm) Model 223 auxiliary
regulator. (Piping not included)

4" LFF127W
High Pressure

Piping not provided

Needle Valve
Reduced Pressure

4" (20mm) 223 regulator


to handle low demands.
Set 10psi (68 kPa)
higher than LFF127W.

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).

24

Capacity
kPa psi

Pressure Drop

138 20

103 15

69 10

34 5

0 0
0 50 100 150 200 250 300
gpm
0 190 380 570 760 246
1140
lpm

Flow

Dimensions Weights

Size

Dimensions
Connection

in.

3
3
4

threaded
flanged
flanged

Weight
C

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

8
8
1218

203
203
308

1618
1618
1618

410
410
410

225
3710
2310

70
93
59

238
334
412

60
95
114

40
42
84

18
19
38

For additional information, reference literature ES-LF127W.

25

Series 2300

Direct Operated Water Pressure Reducing Valves


Sizes: 3" 6" (80 150mm)

LEAD FREE* Series 2300 Direct Operated Water Pressure Reducing Valves

are designed for dead-end water service where the flow is
intermittent and changes rapidly, as on domestic water system. Series 2300 is also
installed to regulate the flow of water to such fast acting equipment as flushometers
and snap cocks. The Series 2300 is recommended where city water pressure is to be
reduced to supply plumbing fixtures to prevent violent pressure fluctuations. The 2300
features Lead Free* construction to comply with Lead Free* installation requirements.
Series 2300

A large Hycar diaphragm ensures a


sensitive response to
the slightest change in
reduced pressure

The design of this


valve minimizes
any danger of dirt
lodging in the stem
guide

This design being selfcontained, no control


lines are required

Essentially balanced single


seat minimizes a
variation in delivery
pressure resulting
from a varying inlet
pressure

No stem guide in bottom flange to collect dirt. These


valves are self-aligning and the guiding of the disc is
independent of the bolted bottom flange.

Features

Designed to close
against the flow. Will
not chatter or produce water hammer.
Operates smoothly and
quietly

Applications

An essentially balanced single seat


minimizes variation in delivery pressure
resulting from varying inlet pressure

Large pressure plate gives ample support to the diaphragm assuring long
life

A large Hycar diaphragm ensures a


sensitive response to the slightest
changes in reduced pressure

Self-contained design, requires no control lines

Packless design eliminates stuffing box


friction
Hycar composition single seat provides for dead-end shutoff and prevents pressure-creep when no flow is
required
Self-aligning design. Eliminates the
need for a stem guide in the bottom
flanges and removes a point of direct
collection that can cause faulty operation
Disc and piston are located to minimize
the possibility of obstruction by dirt

All internal parts accessible by removing blind flange or spring chamber.


Regular maintenance can be performed with the valve body in line
No stuffing box maintenance required

Materials
Body: Cast Iron
Disc:
Hycar Composition
Trim:
Stainless Steel
Diaphragm: Hycar
Spring: Tempered Steel

Industrial plants for washrooms and


processing operations
Apartment buildings, hotels, office
buildings and hospitals to provide each
floor with a steady pressure.
Municipal or plant water main to maintain constant pressure

Pressure Temperature

Maximum Temperature: 150F (66C)


Maximum Pressure: 200psi (13.8 bar)
Reduced Pressure Range: 30 80psi
(207 552 kPa)

Typical Applications
Washroom Water Supply

Series 2300 is a direct operated, balanced, tight seating pressure reducing


valve, opened and closed by small variations in delivery pressure.

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

26

For additional information, reference literature ES-2300.

Series 115 (Globe), 1115 (Angle)


Water Pressure Reducing Automatic Control Valves
Sizes: 114" 16" (32 400mm)
Series 115 (Globe) and 1115 (Angle) Water Pressure Reducing Automatic Control Valves automatically reduce a higher inlet pressure to a constant lower outlet
pressure regardless of changing flow rates and or varying inlet pressure.

Features

Standard Components

Wide range of sizes available


114" 16"
100% Fused epoxy coating inside and
out (FDA and NSF approved, meets
AWWA standards)
Exclusive Quad Sea provides positive
drip-tight closure and longer valve lifespan
Diaphragm actuated (one-moving part)
Hydraulically operated (frictionless)
Top and bottom guided stem
Packless construction
(less-maintenance)

3" and Smaller


Flo-Clean pilot circuit strainer
Adjustable opening speed control
Fixed orifice supply restriction
20 175psi downstream adjustment
range

Models

Optional Components

115 (Globe)/1115 (Angle)


Pressure Reducing
115-2 (Globe)/1115-2 (Angle)
Pressure Reducing/Sustaining
115-3 (Globe)/1115-3 (Angle)
Pressure Reducing/Check
115-4 (Globe)/1115-4 (Angle)
Pressure Reducing/Solenoid On-Off
115-7 (Globe)/1115-7 (Angle)
Pressure Reducing/Surge
115-74 (Globe)/1115-74 (Angle)
Pressure Reducing/Low Flow Bypass
Valve

Adjustable opening speed control


4" and larger
Pilot circuit isolation ball valves
3" and smaller
Y-Pattern pilot circuit strainer
3" and smaller
Adjustable closing speed control (all sizes)
Position indicator (all sizes)
Inlet and outlet pressure gauges (all sizes)

Pressure-Temperature
Adjustable Reduced Pressure Range:

20-175psi (1.3 12 bar)
Optional Reduced Pressure Settings:

0-30psi (0 2 bar),

100-300psi (6.8 20 bar)

4" and Larger


Y-pattern pilot circuit strainer
Pilot circuit isolation ball valves
Fixed orifice supply restriction
20 175psi downstream adjustment
range

For additional information, reference literature C-CACV.

27

Series LFN250

Iron Body Water Pressure


Reducing Valves**
Sizes: 12" 34" (15 20mm)
LEAD FREE* Series LFN250 Iron Body Water Pressure Reducing Valves

are designed to reduce incoming water pressure to a sensible


level to protect plumbing system components and reduce water consumption. This
series is suitable for water supply pressures up to 250psi (17.2 bar) and may be
adjusted from 25 75psi (172 517 kPa). The standard setting is 50psi (345 kPa).
All parts are quickly and easily serviceable without removing the valve from the line.
The optional bypass feature*** permits the flow of water back through the valve into
the main when pressures, due to thermal expansion on the outlet side of the valve,
exceed the pressure in the main supply. The LFN250 features Lead Free* construction to comply with Lead Free* installation requirements.

Features

Models

Integral strainer

Models
LFN250 N
 PT threaded female inlet x
NPT female outlet
LFN250B NPT threaded female inlet
x NPT female outlet with
thermal expansion bypass
feature
Note: Cast iron body regulators are
not intended for buried or pit
services.

Unitized construction for ease of


maintenance
High temperature resisting diaphragm
for hot or cold water
All working parts easily and quickly
serviceable without removing the valve
from the line
Optional bypass feature*** controls
thermal expansion pressure

Pressure Temperature
Temperature Range: 33F 160F

(0.5C 71C)
Maximum Working Pressure: 250psi

(17.2 bar)
Adjustable Reduced Pressure Range:

25 75psi (172 517 kPa)
Standard Reduced Pressure Setting:

50psi (345 kPa)

Materials
Body: Iron
Seat: Stainless steel
Integral Strainer: Stainless steel
Stem: Lead Free* brass
Disc: Lead Free* brass

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.
**A water saving test program concluded that reducing the supply pressure from 80-50psi (551-345 kPa) resulted in a water savings of 30%.
***The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150psi (10.3 bar).

28

For additional information, reference literature ES-LFN250.

Series LF26A, LF263A


Small Pressure Regulators
Sizes: LF26A: 18" 12" (3 15mm)
LF263A: 14" 12" (8 15mm)
LEAD FREE* Series LF26A, LF263A Small Pressure Regulators are general

purpose pressure regulators for water service. The LF26A,


LF263A features Lead Free* construction to comply with Lead Free* installation
requirements. These regulators are ideal for use in beverage dispensers, ice cube
machines and other similar applications. Lead Free* small pressure regulators shall
comply with state codes and standards, where applicable, requiring reduced lead
content.

Features

Materials

Rugged forged Lead Free* Brass body

Body: Lead Free* Brass


Spring Cage:
Aluminum
Disc:
Buna-N stainless steel
Diaphragm:
Reinforced Buna-N

Tee handle adjustment


Oversized orifice

Models

LF26A
2-Way

Pressure Temperature

LF26A 2-way regulator


LF263A 3-way regulator

Temperature Range: 0F 140F



(-18C 60C)
Maximum Working Pressure: 300psi

(21 bar)

C
B
D
A

Dimensions Weights
Model

Size (DN)

Dimensions (APPROX.)
A

LF26A
LF26A
LF26A
LF26A
LF263A
LF263A
LF263A

Weight

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

oz.

gm.

3
8
10
15
8
10
15

218
218
218
218
218
218
218

54
54
54
54
54
54
54

378
378
378
4
478
478
4

98
98
98
100
124
124
100

3
3
3
318
4
4
318

76
76
76
79
100
100
79

22
22
22
22
22
22
22

16
16
16
16
16
16
16

454
454
454
454
454
454
454

8
1
4
3
8
1
2
1
4
3
8
1
2

8
7
8
7
8
7
8
7
8
7
8
7
8

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

For additional information, reference literature ES-LF26A/263A.

29

Series SS-263AP

Compact Stainless Steel Water Regulators


Sizes: 14" 12" (8 15mm)
LEAD FREE* Series SS-263AP Compact Stainless Steel Water Regulators

are designed for use with deionized water, chemical solutions,


high purity water purification systems and low pressure steam, 15psi (1.0 bar), applications. The SS-263AP features Lead Free* construction to comply with Lead Free*
installation requirements. The SS-263AP features Lead Free* construction to comply
with Lead Free* installation requirements.

Features

Materials

Options

R
 ugged investment cast stainless steel
body and cage

Body: Stainless steel ASTM351-CF8M


Spring Cage: Stainless steel ASTM351-CF8M
Disc: Buna-N (FDA) stainless
steel stem
Diaphragm: Reinforced Buna-N
(FDA)
Bottom Plug:
Stainless steel
Bottom Spring: Stainless steel
Trim:
Viton*
*Viton is a registered trademark of
DuPont Dow Elastomers.

add suffix:
G pressure gauge
X
slotted adjusting screw
See Pressure -Temperature section for
reduced pressure range options

Stainless steel adjusting screw


Oversized orifice
14" (8mm) gauge port

Pressure Temperature
Temperature Range: 33F120F

(0.5C 49C)
Maximum Operating Pressure: 400psi

(27.6 bar)

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

30

For additional information, reference literature ES-SS-263AP.

Series P60-M1

Miniature Plastic Water Pressure Regulators


Sizes: 14" (8mm)
LEAD FREE* Series P60-M1 Miniature Plastic Water Pressure Regulators

are ideal for applications where a small economical package is


required. This series is also suitable for deionized water. Series P60-M1 features a balanced piston design for applications where a constant downstream and accurate flow
performance is required. The P60-M1 features Lead Free* construction to comply with
Lead Free* installation requirements.

Options

Features
Corrosion resistant thermoplastic body
C
 ompact design and lightweight
construction

A
 ll internal metal components in
contact with fluid are of 300 series
stainless steel

A
 ll external components are made of
NSF approved thermoplastics

S
 traight through or 90 inlet to outlet
option (suffix 4 option)

A
 ll internal rubber components such as
disc, diaphragm and seals are all FDA
grade elastomers

Bottom clean out plug for service

High capacity

add suffix:
HC 34" (20mm) hose connection
G 14" (8mm) 0-160 gauge
S strainer
4
gauge port or 90 inlet to outlet
QD quick disconnect for plastic tubing
MK Mounting Kit

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

For additional information, request literature ES-P60.

31

Series LF560, LFH560


Mini Water Pressure Reducing Valves
Sizes: 1 8", 14" & 34" Male x 34" Female
(3, 8 & 20 x 20mm) Hose Connection
Series LF560, LFH560 Mini Water Pressure Reducing Valves are

LEAD FREE* designed to reduce incoming water pressure to a sensible level

to protect plumbing system components and reduce water consumption. This series
is ideal where a small economical package is required such as on special industrial
process applications, miscellaneous plumbing applications and OEM equipment. Series
LF560 and LFH560 are suitable for water supply pressures up to 300psi (21 bar). The
LF560, LFH560 features Lead Free* construction to comply with Lead Free* installation
requirements.

Features

Models

Options

Rugged Lead Free* brass body

LF560 Female threaded inlet x female


threaded outlet

Stainless steel stem and spring


Oversized orifices
C
 omes standard with 18" (3mm)
gauge port (plugged)

gauge

LFH560 Female hose connection inlet


x male hose connection outlet
for grid systems. Also used on
recreational vehicles.

H
 eavy duty adjusting screw. Adjusting
screw is both slotted and knurled.
*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

32

For additional information, request literature ES-LF560/LFH560.

Series LF123LP

Water Pressure Reducing Valves


Sizes: 12" 34" (15 20mm)
LEAD FREE* Series LF123LP Water Pressure Reducing Valves are designed

to reduce incoming water pressure to a sensible level to protect


plumbing system components and reduce water consumption. This series is suitable
for water supply pressures up to 200psi (13.8 bar) and may be adjusted from 10
30psi (69 207 kPa). The standard setting is 30psi (207 kPa). All parts are quickly and
easily serviceable without removing the valve from the line. The LF123LP features Lead
Free* construction to comply with Lead Free* installation requirements.

Features

Pressure Temperature

High performance

Temperature Range: 33F 180F



(0.5C 82C)
Maximum Working Pressure: 200psi

(13.8 bar)
Adjustable Reduced Pressure Range:

10 30psi (69 207 kPa)
Standard Reduced Pressure Setting:

30psi (207 kPa)

High flow capacity


Integral stainless steel valve seat
Integral stainless steel strainer
Lead Free* cast copper silicon alloy
body construction
Serviceable in-line

*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.

For additional information, request literature ES-LF123LP.

33

Series LF215

Super Sensitive Low Pressure Regulators


Sizes: 14" 38" (8 10mm)
LEAD FREE* Series LF215 Super Sensitive Low Pressure Regulators are

designed to meet low pressure precision requirements. The


high ratio of diaphragm to orifice provides excellent performance and stability at low
reduced pressure. The Series LF215 is ideally suited for water requirements up to 2.5
gpm (9.5 lpm) due to its Lead Free* brass body and brass & stainless steel internal
parts. The LF215 is also suitable for pressure supply to wall attachment fluidic devices. The LF215 features Lead Free* construction to comply with Lead Free* installation
requirements.
Model LF215

Features

Materials

Rugged forged Lead Free* brass body


for water service
Replaceable stainless steel seat
Large diaphragm provides exceptional
performance, particularly under 10psi
(69 kPa)
30 mesh stainless steel strainer

Body: Lead Free* Brass


Seat: Replaceable stainless steel
Strainer: Stainless steel

Pressure Temperature
Temperature Range: 0F 120F

(-18C 49C)
Maximum Working Pressure: 300psi

(20.7 bar)
Model LF215
cutaway

34

For additional information, request literature ES-LF215.

Model 276H300, IWTG


Hose Connection Gauges
Dial Size: 212" (65mm)
Series 276H300 and IWTG Hose Connection Gauges are used to test water supply pressures within a distribution system. The 276H300 and IWTG gauges have
red indicator hands that hold at the highest reading registered for detection of thermal expansion pressure surges. Both the 276H300 and IWTG series feature black
enamel steel cases, Kostil Polymer windows, 34" (20mm) H.T. hose connections,
and copper alloy Bourdon tube sensing elements. Accuracy is ASME, Type B.
Series IWTG gauges are available in a 0 to 200psi (13.8 bar) pressure rating scale.
The Series 276H300 gauges are available in a 0 to 300psi (20.7 bar) pressure rating
scale.

Features
Black enamel steel case
Kostil polymer window
C
 opper alloy Bourdon sensing
element
Tin alloy welding
4" (20 mm) H.T. hose connection
3

ASME Type B accuracy

Models

Standards

276H300 0
 - 300psi (20.7 bar)
pressure rating scale
IWTG
0
 - 200psi (13.8 bar) pressure
rating scale

ISO 9002 quality standard


ASME B40.100

Approvals

Working Temperature: 40F to 140F



(4C to 60C)

Certified by The Northern Certification


Society of Italy
(Det Norske Verita Italia S.r.l.)

Temperature

For additional information, reference literature ES-276H300_IWTG.

35

Series LFDPG-3

Center Back-Entry Pressure Gauges


Dial Sizes: 112", 2" (40, 50mm)
LEAD FREE* Series LFDPG-3 Center Back-Entry Pressure Gauges are used in

commercial, residential, and institutional HVAC applications. They


gauges feature ABS polymer cases, Kostil Polymer windows, 18" or 14" NPT connections, and copper alloy Bourdon tube sensing elements. The LFDPG-3 features Lead
Free* construction to comply with Lead Free* installation requirements. Accuracy is
ASME, Type B. Series LFDPG-3 gauges are available in various pressure rating scales.
The dual scale features PSI and kPa measurements.

Features

Standards

ASME B40.100

ABS polymer case


Kostil polymer window
Copper alloy Bourdon sensing element
Tin alloy welding
1
8" or 14" NPT connections
ASME Type B accuracy

Approvals

36

Temperature
Working Temperature: -4F to 176F

(-20C to 80C)

Dimensions
Model

Certified by The Northern Certification


Society of Italy
(Det Norske Verita Italia S.r.l.)

LFDPG-3

Scale

connection Size (DN)


in.

LFDPG3-112
LFDPG3-112

0 60psi
0 160psi

413 kPa
11 bar

8
1
8

For additional information, reference literature ES-LFDPG-3.

Dial Size

mm

in.

mm

3
3

112
112

38
38

Series LFDPG-5
Top Entry Pressure Gauges
Dial Sizes: 2" (50mm)
LEAD FREE* LFDPG-5 Top-Entry Pressure Gauges are used in commercial,

residential, and institutional HVAC applications. The LFDPG-5


features Lead Free* construction to comply with Lead Free* installations requirements.
These gauges feature ABS polymer cases, Kostil Polymer windows, 18" or 14" NPT
connections, and copper alloy Bourdon tube sensing elements. Accuracy is ASME,
Type B. Series LFDPG-5 gauges are available in various pressure rating scales. The
dual scale features PSI and kPa measurements.

Features

Standards

ISO 9002 quality standard.


ASME B40.100

ABS polymer case


Kostil polymer window
Copper alloy Bourdon sensing element
Tin alloy welding
1
 8" or 14" Lead Free Brass NPT connections
ASME Type B accuracy

Approvals
Certified by The Northern Certification
Society of Italy
(Det Norske Verita Italia S.r.l.)

LFDPG-5

Temperature
Working Temperature: -4F to 176F

(-20C to 80C)

Dimensions
Model

Scale

connection Size (DN)


in.

LFDPG5-2

0 160psi

11 kPa

Dial Size

mm

in.

mm

50

For additional information, reference literature ES-LFDPG-5.

37

Jumper Kits

Temporary Bypass for Water


Pressure Reducing Valves
Sizes: 34" 11/4" (20 32mm)
Jumper Kits are used in new construction as a temporary
bypass, prior to the actual installation of a water pressure
reducing valve on potable water supply systems.
The use of a temporary jumper permits testing of the building
piping system for leaks and pressure loss and facilitates pipe
flushing prior to the installation of the water pressure reducing
valve. On unsecured job sites, the jumper kit reduces loss from
theft or vandalism.
Jumper Kits come complete with union connections, washers, and a brass or plastic pipe nipple with male union
threads. The length of the jumper nipple matches the valve
lay length, allowing the piping to be completed prior to the
installation of a water pressure reducing valve and permitting
quick change out from the jumper to the valve. The jumper
kits include a stainless steel strainer screen to provide protection from debris downstream of the valve.

A
C

Jumper Kit Exploded View


Kit Consists of:
A Union Nut (2)

D Jumper Nipple

B Sweat Tailpiece (2)

E Screen

C Fiber Washer (2)

How to order jumper kits

4" JK P-345 S

Example: 34" JK P-345 S

Model

34", 1", 114", 112", 2"


Jumper Kit Designation:
Nipple Type:
P = Plastic

Fits Valve Model:


25 = LF25AUB 345 = LFN45 (34"1")

JK-P-25 S
114"
JK-P-55 S
114"
JK-P-25 S
2"
Jumper Kits Include: Jumper Nipple, strainer screen, 2 fiber washers, 2 union nuts and
tailpieces as described above.
When removing Jumper Nipple and inserting the water pressure reducing valve, two
O-rings (ordered separately) are required. Refer to literature PL-RP-GP for O-ring ordering information.

Connection:
M = Male brass solder

38

Size

Female x Female Copper Sweat Tailpiece

Size:

B = Brass

Jumper Kits COMPLETE KITS WITH PLASTIC NIPPLE

S = Female copper solder

For additional information, reference literature ES-JumperKits.

NOTES

39

NOTES

40

For Technical and Ordering Assistance, please call us at 978-688-1811.


To locate your nearest Watts representative, please click on our
find a sales rep locator on watts.com.

Represented by:

USA: Tel. (978) 688-1811 Fax: (978) 794-1848 www.watts.com


Canada: Tel. (905) 332-4090 Fax: (905) 332-7068 www.watts.ca

A Watts Water Technologies Company

PG-PRV 1352

MF10123

2014 Watts

Вам также может понравиться