Вы находитесь на странице: 1из 5

The ANSI Pump

The ANSI pump is designed and built to the dimensional standards of the American
National Standards Institute. Over the years, the ANSI pump has become the preferred
style of end suction pumps, not only for chemical process applications, but also for
water and other less aggressive services. The Standard provides for dimensional
interchangeability of pumps from one manufacturer to another.

The API Pump


On the other hand, the API pump meets the requirements of the American Petroleum
Institute Standard 610 for General Refinery Service. This style is almost the exclusive
choice for applications in the oil refinery industry, where it handles higher temperature
and pressure applications of a more aggressive nature that are common in the
refineries.

The Service Considerations


In both the chemical and petrochemical industries, many of the liquids being pumped
require more consideration than merely environmental damage and pumping efficiency
and reliability. It is necessary to consider the aspect of personal safety. Therefore, the
choice between the ANSI pump and the API pump must take into account the specific
fluid properties as well as the operating conditions.
Advertisement
One of the main differences between these choices is predominantly a result of the
differences in casing design ratings which are as follows:
ANSI Pump Rating = 300-psig at 300-deg F
API Pump Rating = 750-psig at 500-deg F
In view of these figures, it is apparent that the API pumps should be considered for
higher pressure and temperature services than the lighter duty ANSI pump.

Case Designs
Both styles are of a single stage design with a radially split casing to accommodate a
back pullout arrangement for ease of maintenance.

Advertisement
Most ANSI pumps, and some API pumps, employ a single volute design in the interior
passages of the casing. This is particularly evident in the smaller sizes that involve low
flow rates and lower specific speeds of the impeller.
As shown in Figure 1, the area of the volute increases at a rate that is proportional to the
rate of discharge from the impeller, thus producing a constant velocity at the periphery
of the impeller. This velocity energy is then changed into pressure energy by the time
the fluid enters the discharge nozzle.

Figure 1. Single Volute Case


The peculiar shape of the volute also produces an uneven pressure distribution around
the impeller which, in turn, results in an imbalance of the thrust loads around the
impeller and at right angles to the shaft. This load must be accommodated by the shaft
and bearings, and much has been discussed on this problem in recent years.
This load is at its maximum when the pump is run at the shutoff condition, and gradually
decreases as the flow rate approaches the B.E.P. If the pump operates beyond the
B.E.P., the load increases again, but in the opposite direction on the same plane.
Examination of the resultant shaft deflection problems has indicated that the radial plane
on which the out of balance load acts is approximately 60-deg counterclockwise from
the cut-water of the volute.

Figure 2. Double Volute Case


Most of the larger API pumps are produced with a double volute design to reduce these
loads on high flow and high head units. This is accomplished by balancing the opposing
out-of-balance loads from each volute. While the cost of this is a slight reduction in
efficiency, it is considered a small price to pay for the increased reliability that ensues.
Another casing feature found in many API pumps is the top suction/top discharge
arrangement, where the suction nozzle is located at the top of the casing adjacent to the
discharge nozzle, rather than on the end. The drawback of this design is that, for most
of these pumps, the NPSH required is usually greater than in the end suction
arrangement in order to accommodate the friction losses in the tortuous path from the
suction flange to the eye of the impeller.

Back Cover Arrangements


One of the major differences between the ANSI and API pump casings is in the manner
in which the back cover is secured to the casing.

Figure 3. Typical ANSI Pump

Courtesy of Flowserve Corporation

In the ANSI design shown in Figure 3, the back cover and gasket is held against the
pump casing by the bearing frame adaptor, which is most frequently supplied in cast
iron. This usually results in a gap between the mating faces of the frame adaptor and
the pump casing that has the potential to permit uneven torquing of the bolts. This may
cause a fracture of the adaptor in the event of a higher than normal pressurization of the
casing by the process system.
- See more at: http://www.pumpsandsystems.com/topics/pumps/which-process-pumpshould-i-use-ansi-or-api#sthash.8pRbmjzN.dpuf
by Ross Mackay

Figure 4. Typical API Pump

Courtesy of Flowserve Corporation

The API design in Figure 4 bolts the back cover directly to the casing and uses a
confined, controlled compression gasket with metal to metal fits. The adaptor is bolted
independently to the back cover and does not play a part in the pressure boundary of
the pump casing.

Mounting Feet
Another difference between the two pump styles is the configuration of the mounting
feet. All ANSI pump casings are mounted on feet projecting from the underside of the
casing and bolted to the baseplate. If these pumps are used on high temperature
applications, the casing will expand upwards from the mounting feet and cause severe
thermal stresses in the casing which will detrimentally affect the reliability of the pump.
Operation at lower temperatures will not be affected by this feature.
Advertisement
On the other hand, API pumps are mounted at the horizontal centerline of the casing on
feet projecting from each side of the casing and bolted to pedestals which form part of
the baseplate. This arrangement provides the API pump with the advantage of being
able to operate with pumpage at elevated temperatures. As the pump comes up to
temperature in such cases, any expansion of the metal will be above and below the
casing centerline and will exert minimal amounts of stress to the casing, thus
contributing to the optimum reliability of the pump.
The ability to handle higher temperature services is also evident in the bearing housings
of the API pumps, which tend to be much more robust in design and also accommodate
cooling jackets with a greater capacity of cooling water.
Lets get practical. By keeping these factors in mind during the selection process, you
can finish up with the correct pump design that has been properly selected to provide a
profitable and reliable operating system.
- See more at: http://www.pumpsandsystems.com/topics/pumps/which-process-pumpshould-i-use-ansi-or-api?page=2#sthash.RuwglToO.dpuf