Академический Документы
Профессиональный Документы
Культура Документы
MWI-2014 Software
Overview
Installing software
Starting software and basic operations
Detailed software capabilities
Starting software
Installing:
MWI-2014 Software
After downloading the mwi2014.exe file, save it on the hard drive of the
computer that will be using the software
Do not install on a network system
If not able to download the *.exe file, there is an option to download the same file
that is in a zip format
MWI-2014 Software
MWI 2010
Thermal Coefficient of Dk
Dissipation Factor
Thermal
conductivity
of the
substrate
When floating
the mouse over
the material
name,
additional
information will
be shown.
MWI 2010
MWI-2014 Software
Only standard thicknesses of the
selected material are shown. This
can be overridden.
MWI 2010
MWI-2014 Software
Conductor conductivity
can be entered; however
it will affect all conductor
layers of the circuit
MWI-2014 Software
MWI-2014 Software
For simple
impedance
calculations the
default z-axis Bulk
Dk can be used
More accurate
results can be
achieved by using
the Digital Dk
Values
MWI-2014 Software
For RF applications
at a specific
frequency or narrow
frequency range,
then the RF Design
Dk values can be
used.
For more
information on
Design Dk please
refer to literature
on the Rogers Technology Support Hub at:
http://www.rogerscorp.com/acm/technology/index.aspx
MWI-2014 Software
Synthesis will generate the conductor width or spacing, given an impedance target.
Analytical will solve for impedance and other electrical properties given circuit geometry.
MWI-2014 Software
MWI-2014 Software
Models in the
Compare database
can be edited
10
MWI-2014 Software
5 models can be
compared at one time
11
MWI-2014 Software
Graphs of insertion
loss can be compared
as well
12
MWI-2014 Software
MWI-2014 Software
14
MWI-2014 Software
15
MWI-2014 Software
16
MWI-2014 Software
17
MWI-2014 Software
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
-0.05
-0.1
-0.15
Loss (dB/in)
-0.2
Dielectric Loss
Conductor Loss
-0.25
Total Loss
-0.3
-0.35
-0.4
-0.45
-0.5
Frequency (GHz)
18
MWI-2014 Software
19
MWI-2014 Software
20
MWI-2014 Software
21
MWI-2014 Software
22
MWI-2014 Software
23
MWI-2014 Software
The information in this presentation is intended to assist you in working with Rogers' High-Frequency Materials. It is not intended to and does not create any
warranties, express or implied, including any warranty of merchantability or fitness for a particular purpose or that any results show in this presentation will
be achieved by a user for a particular purpose. The user is responsible for determining the suitability of Rogers' High Frequency Materials for each
application.
This presentation may not be reproduced, copied, published, broadcast, transmitted or otherwise distributed without the written approval of Rogers
Corporation.
2009 Rogers Corporation. All rights reserved
24