Академический Документы
Профессиональный Документы
Культура Документы
epoc
Page 5
EnergyMax Stratus
Page 8
createchange is our commitment to meeting the challenges and opportunities posed by rising
energy costs, environmental concerns, energy legislation, LEED certification, utility rebates, and
EPAct tax deductions. It is a product philosophy dedicated to development of innovative, high
performance luminaires.
To receive the createchange trademark, a product must meet three criteria.
When compared to fixtures traditionally used in lighting applications, createchange luminaires must:
1. Save at least 20% in energy
2. Maintain lighting quality
3. Maintain light levels
We achieve these goals through innovative design that optimizes performance through our choice of
lamp, ballast, reflector, refractor, and control technologies, to create ultra-high efficiency luminaires
that deliver proper light levels and distribution at the lowest possible wattage.
EnergyMax Intersect
Page 13
Page 14
EnergyMax Parabolic
Page 19
Bi-Level Luminaire
Page 49
VersaBay
Page 59
XFSW
Page 82
XTS
Page 85
Morph
Page 93
Energy Benefits
Energy efficient lighting solutions can help cut lighting costs by up to 52% without sacrificing light
levels; even higher savings can be realized when combined with lighting controls.
createchange lighting solutions typically pay for themselves in under two years when installed in
new buildings.
createchange solutions costs are often recouped in one to three years following installation in a
remodel project.
createchange solutions, if used wherever possible, would lower the nations electrical demand by
over 10%, saving ratepayers nearly $17 billion annually.
Collateral Benefits
EPAct
createchange energy solutions can help leverage federal tax deductions by up to $0.60 per square
foot when meeting guidelines established by the Energy Policy Act of 2005.
LEED
Reducing power demand is the largest single consideration when applying for LEED certification.
createchange energy solutions help achieve that goal.
Utility Rebates
Many electrical utilities offer substantial rebates for energy-efficient lighting. createchange energy
solutions typically qualify, in many cases completely defraying most or all of the cost of the fixture.
Environmental Benefits
The use of createchange energy solutions contributes significantly to the reduction of greenhouse
gases. If just the estimated 50 million 400W metal halide high bays and 100 million 3-lamp
parabolics in use today were converted to their createchange equivalents, we could save 43 million
metric tons of CO emissions annuallyan amount equal to 1.7% of all CO caused by the generation
of electricity in the U.S. This equates to taking 7.8 million cars of the road. Replacing troffers and
other fixtures that use outdated technology could save far greater amounts.
A rapid transition to energy efficiency and renewable energy sources will combat global climate
change, protect human health, create new jobs, protect wildlife habitats, and ensure a secure,
affordable energy future.
For more createchange information, visit www.columbialighting.com
EPC
RECESSED ARCHITECTURAL
Ordering Information
EPC
Model
EPC epoc Full
Distribution
Luminaire
No. of lamps
1 One
2 Two
Size
14 1' 4'
22 2' 2'
24 2' 4'
Ceiling type
Shielding
G Grid
DL Delta Profile
SM Surface SH
Shield Profile
Mount
For hard
ceilings use
flange kit.
Air function
Blank Static
A Air Return
Side Slots
(N/A 1' 4')
Voltage
U 120V-277V
347 347V2
Lamp type
Ballast
14
17
24
28
32
Accessories
(Order Separately)
FK14 1' 4' Flange Kit
FK22 2' 2' Flange Kit
FK24 2' 4' Flange Kit
FKCR Flange Kit Row Adaptor
Product Availability
SIZE
NO. OF
LAMPS
LAMP TYPE
1' 4'
28, 32, 54
1' 4'
28, 54
2' 2'
2' 4'
28, 32, 54
24"
EPC24
Options
C388
C488
C588
EL
EL5
GLR
GMF
NYC
NYCU
3-Wire Flex
4-Wire Flex
5-Wire Flex
Emergency Battery Pack, T8
Emergency Battery Pack, T5
Fast Blow Fuse
Slow Blow Fuse
NYC Compliant
NYC Compliant, Union Label
Lamps Installed
FO730
FO735
FO741
FO830
FO835
FO841
PLUS30
PLUS35
PLUS41
FOH830
FOH835
FOH841
F5830
F5835
F5841
F5H830
F5H835
F5H841
FTT830
FTT835
FTT841
3"
3"
3"
24"
EPC22
12"
EPC14
TRA
Features
Ordering Information
TRA
Model
TRA Transition
High Efficiency
Architectural
Lensed
CLO
No. of Lamps in
Cross section
1 One
2 Two
3 Three
Ceiling type
G Grid Lay-in
SM Surface
Ballast
E Electronic T8, Instant
Options
EL
EL5
FO730
FO735
FO741
FO830
FO835
FO841
F5830
Start
ED Electronic Dimming T8
Mount
and T5
Lamp type
14
17
24
28
32
Instant Start
Shielding
CLO Clear Linear
Prism
Acrylic with
Overlay
3E
3EP
ELW
3ELW
E104
Accessories
(Order Separately)
FK14 1' 4' Flange Kit
FK22 2' 2' Flange Kit
FK24 2' 4' Flange Kit
ESD104
Programmed Start
3-Lamp Electronic T8,
Instant Start
3-Lamp Electronic T8,
Programmed Start
2-Lamp Electronic T8,
0.77 Ballast Factor, Low
Wattage, Instant Start
3-Lamp Electronic T8,
0.77 Ballast Factor, Low
Wattage, Instant Start
Electronic T8, 1.04
Ballast Factor, Instant
Start
Electronic T8, 1.04
Ballast Factor, Step
Dimming, Programmed
Start1
Voltage
U 120V-277V
347 347V
F5835
F5841
PLUS30
PLUS35
PLUS41
FTT830
FTT835
FTT841
C388
C488
DG
NYC
NYCU
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS IN
FIXTURE
LAMP TYPE
HEIGHT
1' 4'
1
1
2
3
1
2
2
3
28, 32, 54
40TT
28, 32, 54
28, 32, 54
5"
5"
5"
5"
2' 2'
2
3
2
3
4"
4"
2' 4'
2
2
3
3
2
4
3
6
28, 32, 54
40TT
28, 32, 54
40TT
4"
4"
4"
4"
SIZE
51/2"
12"
TRA14
43/4"
24"
TRA22, TRA24
EMSE
RECESSED ARCHITECTURAL
Ordering Information
EMSE
No. of lamps
2 Two
Model
EMSE EnergyMax
Stratus
E-Series1
Ceiling type
G Grid
SM Surface Mount
MPO
SHIELDING
MPO Metal Perf
w/Overlay
U
Voltage
U 120V-277V
Size
22 2' 2'
24 2' 4'
Lamp type
17 2', T8: 17 Watt
32 4', T8: 32, 30, 28
or 25 Watt
Ballast
E104 Electronic T8, 1.04 Ballast Factor,
Instant Start1 (N/A 1-Lamp)2
Accessories
(Order Separately)
FK22 2' 2' Flange Kit
FK24 2' 4' Flange Kit
FKCR Flange Kit Row Adaptor
Options
FO730
FO735
FO741
FO830
FO835
FO841
PLUS30
PLUS35
PLUS41
EL
GLR
GMF
DG
NYC
NYCU
C388
C488
Product Availability
SIZE
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS IN
FIXTURE
LAMP TYPE
2' 2'
17
2' 4'
32
51/2"
12"
EMSE14
43/4"
24"
EMSE22, EMSE24
STE
Features
Ordering Information
STE
Model
STE Stratus
E-Series
Recessed
Indirect
No. of Lamps in
Cross section
1 One
2 Two
3 Three
MPO
Ceiling type
G Grid Lay-in
SM Surface Mount
Ballast
E Electronic T8, Instant Start
ED Electronic Dimming T8
Options
EL
EL5
FO730
FO735
FO741
FO830
FO835
FO841
F5830
and T5
Size
14 1' 4'
22 2' 2'
24 2' 4'
Lamp type
14
17
24
28
32
Shielding
MPO Metal Perf
w/Overlay
3EP
ELW
3ELW
Programmed Start
3-Lamp Electronic T8,
Instant Start
3-Lamp Electronic T8,
Programmed Start
2-Lamp Electronic T8,
0.77 Ballast Factor, Low
Wattage, Instant Start
3-Lamp Electronic T8,
0.77 Ballast Factor, Low
Wattage, Instant Start
Voltage
U 120V-277V
347 347V
F5835
F5841
FTT830
FTT835
FTT841
C388
C488
DG
NYC
NYCU
Accessories
(Order Separately)
FK14 1' 4' Flange Kit
FK22 2' 2' Flange Kit
FK24 2' 4' Flange Kit
Product Availability
51/2"
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS IN
FIXTURE
LAMP TYPE
HEIGHT
1' 4'
1
1
2
3
1
1
2
3
28, 32, 54
40TT
28, 32, 54
28, 32, 54
5"
5"
5"
5"
2' 2'
2
3
2
3
4"
4"
2' 4'
2
2
3
3
2
4
3
6
28, 32, 54
40TT
28, 32, 54
40TT
4"
4"
4"
4"
SIZE
12"
STE14
43/4"
24"
STE22, STE24
STEL
RECESSED ARCHITECTURAL
STEL
Model
STEL Stratus
E-Series
Center
Louver
Recessed
Indirect
MPO
No. of lamps
1 One
2 Two
3 Three
Ceiling type
G Grid Lay-in
SM Surface Mount
Shielding
MPO Metal Perf w/Overlay
Voltage
U 120V-277V
347 347V
Size
14 1' 4'
22 2' 2'
24 2' 4'
Lamp type
14
17
24
28
32
Accessories
(Order Separately)
FK14 1' 4' Flange Kit
FK22 2' 2' Flange Kit
FK24 2' 4' Flange Kit
Louver type
High Efficiency (H)*
HLS Low Iridescent Specular
Ballast
E Electronic T8, Instant Start
ED Electronic Dimming T8
Parabolic
HMA Matte Anodized Low
Iridescent Semi-Specular
EP
ETT
EPTT
3E
Overly
WPBO White Perforated Cross Baffle
with Baffle Overlay
*N/A with 3-40TT Lamps
3EP
ELW
3ELW
and T5
Electronic T5, T5HO, or T8,
Programmed Start
Electronic Twin Tube,
Instant Start
Electronic Twin Tube,
Programmed Start
3-Lamp Electronic T8,
Instant Start
3-Lamp Electronic T8,
Programmed Start
2-Lamp Electronic T8,
0.77 Ballast Factor, Low
Wattage, Instant Start
3-Lamp Electronic T8,
0.77 Ballast Factor, Low
Wattage, Instant Start
Options
EL Emergency
Battery Pack
EL5 Emergency
GLR
GMF
DG
NYC
NYCU
Battery Pack, T5
Fast Blow Fuse
Slow Blow Fuse
Dust Guard
NYC Compliant
NYC Compliant,
Union Label
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS IN
FIXTURE
LAMP TYPE
HEIGHT
1' 4'
1
1
2
1
2
2
28, 32, 54
40TT
28, 32, 54
5"
5"
5"
2' 2'
1
2
3
1
2
3
14, 17, 24
14, 17, 24, 40TT
14, 17, 24, 40TT*
4"
4"
4"
2' 4'
1
2
2
3
1
2
4
3
28, 32, 54
28, 32, 54
40TT
28, 32, 54
4"
4"
4"
4"
SIZE
51/2"
12"
STEL14
43/4"
24"
STEL22, STEL24
STS
Features
Ordering Information
STS
Model
STS Stratus
No. of Lamps in
Cross Section
Recessed
Indirect
Side Basket
MPO
Ceiling type
G Grid Lay-in
SG Slot Grid
SM Surface Mount
1 One
2 Two
4 Four
Air function
Blank Static
A Air Handling
Voltage
U 120V-277V
347 347V
Size
14 1' 4'
22 2' 2'
24 2' 4'
Lamp type
14
17
24
28
32
Shielding
MPO Metal Perf
w/Overlay
Ballast
NOTE: See Technical Section for
other ballast options.
E Electronic T8, Instant Start
4E 4-Lamp Electronic T8,
Instant Start
ED Electronic Dimming T8 and T5
EP Electronic T5, T5HO, or T8,
Programmed Start
ETT Electronic Twin Tube,
Instant Start
Options
EL Emergency
GLR
GMF
NYC
NYCU
Battery Pack
Fast Blow Fuse
Slow Blow Fuse
NYC Compliant
NYC Compliant,
Union Label
Accessories
(Order Separately)
FK14
FK22
FK24
FKCR
Product Availability
5"
5"
12"
STS14-1
NO. OF LAMPS IN
FIXTURE
LAMP TYPE
HEIGHT
24"
STS22-240TT, STS24-240TT
1' 4'
1
1
2
1
2
2
28, 32, 54
40TT
28, 32, 54
5"
5"
5"
2' 2'
2
2
4
2
2
4
14, 17, 24
40TT
14, 17, 24
5"
5"
5"
2' 4'
2
2
4
2
4
4
28, 32, 54
40TT
28, 32, 54
5"
5"
5"
5"
5"
24"
STS22-217, STS24-232
10
NO. OF LAMPS IN
CROSS SECTION
SIZE
24"
STS22-417, STS24-432
STSL
RECESSED ARCHITECTURAL
Ordering Information
STSL
Model
STSL Stratus
Side Basket
with Louver
No. of Lamps in
Cross Section
Ceiling type
G Grid Lay-in
SG Slot Grid
SM Surface Mount
1 One
2 Two
4 Four
MPO
Shielding
MPO Metal Perf
w/Overlay
Air function
Blank Static
A Air Handling
Voltage
U 120V-277V
347 347V
Size
14 1' 4'
22 2' 2'
24 2' 4'
Lamp type
14
17
24
28
32
Louver finish
GW Gloss White Enamel
LS Low Iridescent Specular
Parabolic Louver
MA Matte Anodized Low
Iridescent SemiSpecular Aluminum
M4R 95% Reflective Specular
Aluminum
Ballast
NOTE: See Technical Section for other
ballast options.
E Electronic T8, Instant Start
ED Electronic Dimming T8 and T5
EP Electronic T5, T5HO, or T8,
Programmed Start
ETT Electronic Twin Tube, Instant Start
Options
EL Emergency
GLR
GMF
NYC
NYCU
Battery Pack
Fast Blow Fuse
Slow Blow Fuse
NYC Compliant
NYC Compliant,
Union Label
Accessories
(Order Separately)
FK14 1' 4' Flange Kit
FK22 2' 2' Flange Kit
FK24 2' 4' Flange Kit
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS IN
FIXTURE
LAMP TYPE
HEIGHT
1' 4'
1
1
2
1
2
2
28, 32, 54
40TT
28, 32, 54
5"
5"
5"
2' 2'
2
2
4
2
2
4
14, 17, 24
40TT
14, 17, 24
5"
5"
5"
2
2
4
2
4
4
28, 32, 54
40TT
28, 32, 54
5"
5"
5"
SIZE
2' 4'
5"
5"
11"
STSL14-132
24"
STSL22-417, STSL24-432
5"
24"
STSL22-217, STSL24-232
11
STP
Features
Ordering Information
STP
Model
STP Stratus
Surface or
Pendant
Mounted
Shielding
MPO Metal Perf w/Overlay
WCBMPO White Cross Baffle inset
No. of Lamps in
cross section
2 Two
in perforated metal
WPBMPO White Perforated
Cross Baffle inset in
perforated metal
See Product
Availability table
below.
SIZE
14 1' 4'
18 1' 8'
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28 or 25 Watt
54 4', T5HO: 54 or 51 Watt
Reflector Type
ST Solid Type Reflector
Options
EL Emergency
Voltage
U 120V-277V
347 347V
(Std.)
U Apertured Uplight
Battery Pack
(Small case size)
GLR Fast Blow Fuse
GMF Slow Blow Fuse
NYC NYC Compliant
NYCU NYC Compliant,
Union Label
For more options see
pages 96-112.
Reflector
Ballast
Note: See Technical Section for other
ballast options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8, Instant Start
4E 4-Lamp Electronic T8, Instant Start
EP Electronic T8, Programmed Start
Accessories
(Order separately)
CM24 24" Adjustable Cable
Mounting Kit
Mounting Kit
Cable mounting kits are ordered and
shipped separately from fixture. Other
lengths are available on request.
12"
Product Availability
45/16"
STP14-2
12
SIZE
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS
IN FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
1' 4'
28, 32, 54
12"
483/16"
45/16"
1' 8'
28, 32, 54
12"
963/16"
45/16"
EMI
RECESSED ARCHITECTURAL
Ordering Information
EMI
Model
EMI EnergyMax
Intersect2
No. of lamps
2 Two
Ceiling type
G Grid
Size
22 2' 2'5
24 2' 4'
Lamp type
14
17
24
28
31U1
Ballast
E Electronic T8, 0.88 Ballast Factor, Instant
Start
Accessories
(Order Separately)
FK22 2' 2' Flange Kit
FK24 2' 4' Flange Kit
FKCR Flange Kit Row Adaptor
EP
EP95
ESD95
EP115
ESD115
ETT
EPTT
Voltage
U 120V-277V
347 347V3
Options
FO730
FO735
FO741
FO830
FO835
FO841
PLUS830
PLUS835
PLUS841
FOH830
FOH835
FOH841
F5830
F5835
F5841
F5H830
F5H835
F5H841
C388
C488
EL
GLR
GMF
NYC
NYCU
Product Availability
SIZE
NO. OF
LAMPS
LAMP TYPE
LOUVER
CONFIGURATIONS
2' 2'
2 3 (6)
2' 4'
28, 32, 54
2 6 (12)
3"
4"
9"
23"
EMI22-2
9"
23"
EMI24-2
13
ZPT
Features
Ordering Information
ZPT
Model
ZPT Zero Plenum
No. of lamps
2 Two
Troffer
Size
14 1' 4'
22 2' 2'
24 2' 4'
Ceiling type
G Grid Lay-in
SM Surface Mount2
Lamp type
14
24
28
54
Recessed only.
Zero Plenum may be ordered as a factory-assembled surface mounted
unit ordered as grid (G) ceiling type and surface mounted in the field
using the ZPTSMK surface mounting kit.
3
Where available.
2
1"
1"
1"
24"
PRF - Metal Perf with Overlay 2 4
12"
FCB - Flush Curved Baffle 1 4
1"
12"
LSR - Linear Prismatic Lens 1 4
1"
1"
Surface Mount
14
10"
Compressed Dimension 1 4
1"
24"
FCB - Flush Curved Baffle
Voltage
U 120V-277V
347 347V
Ballast
NOTE: See Technical Section for
other ballast options.
EP Electronic T5, 1.00 Ballast
Factor (28W or 54W)
EP95 Electronic T5, 0.95 Ballast
Factor (28W only)
EP115 Electronic T5, 1.15 Ballast
Factor (28W only)
ED Electronic T5, 1.00 Ballast
Factor, Variable Dimming
Ballast (28W or 54W)
ESD95 Electronic T5, 0.95 Ballast
Factor, Step Dimming
(28W only)
ESD115 Electronic T5, 1.15 Ballast
Factor, Step Dimming
(28W only)
Note: Step dimming ballasts use
two hot leads for 100% (both on)
or 50% (one on) power.
Options
C38890 3-Wire Flex, 90
C48890
GLR
GMF
TB4
EL5
F5835
F5841
NYC
NYCU
Connector1
4-Wire Flex
(Step Dimming or
-EL Option1
Fast Blow Fuse
Slow Blow Fuse
(4) Bulk T-Bar Clips1
Emergency Battery
Pack (N/A 2 x 2)
35K 85CRI T5
or T5HO Lamps
Installed
41K 85CRI T5
or T5HO Lamps
Installed
NYC Compliant
NYC Compliant,
Union Label
Product Availability
1"
22"
Compressed Dimension
Reflector
O Open (N/A with PRF)
R Ribbed Curve (N/A w/ 1 4)
S Smooth Curve (N/A w/ 1 4)
Shielding
FCB Flush Curved Baffle
LSR Linear Prismatic
1"
SIZE
NO. OF
LAMPS
LAMP
TYPE
COMPRESSED
WIDTH
INSTALLED
WIDTH
LENGTH
HEIGHT
1' 4'
28, 54
10"
11"
47"
1"
2' 2'
14, 24
22"
23"
23"
1"
2' 4'
28, 54
22"
23"
47"
1"
COV
Covelight
Features
T8, T5 or T5HO
RECESSED ARCHITECTURAL
Ordering Information
COV
Model
COV Covelight
No. of Lamps
in Cross Section
Size
2 2'
3 3'
4 4'
6 6'
8 8'
1 One
2 Two (N/A with TT lamps)
See Product Availability
table below.
Lamp type
Ballast
14
17
21
24
25
28
32
Product Availability
SIZE
2'
3'
4'
6'
8'
Voltage
U 120V-277V
347 347V
3716"
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
1
1
2
1
1
2
17, 40TT
14, 24
14, 17, 24
7516"
6"
7516"
24"
221116"
24"
3716"
1"
3716"
1
1
2
1
1
2
25
21, 39
21, 25, 39
7516"
6"
7516"
36"
34"
36"
3716"
1"
3716"
1
1
2
1
1
2
32
28, 54
28, 32, 54
7516"
6"
7516"
48"
45516"
48"
3716"
1"
3716"
1
1
2
2
2
4
25
21, 39
21, 25, 30
7516"
6"
7516"
72"
69"
72"
3716"
1"
3716"
1
1
2
2
2
4
32
28, 54
28, 32, 54
7516"
6"
7516"
96"
92716"
96"
3716"
1"
3716"
Options
EL
GLR
GMF
MS
SMS
SMSS
NYC
NYCU
3716"
22932"
22932"
7516"
7516"
COV4-132
3716"
22932"
COV2-140TT
1"
7516"
COV4-232
6"
COV4-128, COV4-154
3716"
22932"
7516"
COV4-228, COV4-254
15
BR
RECESSED ARCHITECTURAL
Features
Ordering Information
BR
Model
BR Brio T5
Low Glare
No. of lamps
2 Two
3 Three
See Product Availability
table below.
Size
22 2' 2'
24 2' 4'
Ceiling type
G Grid
SG Slot Grid
SM Surface
Lamp type
14
24
28
54
EP
PERFORATED FACE
MPO Metal Perf
w/Overlay
Voltage
U 120V-277V
347 347V
Options
F5830 30K 85CRI T5 or T5HO
Lamps Installed
Ballast
Louver finish
LS Low Iridescent Specular
MA Matte Anodized Low
1WW
2WW
C388
C488
EL5
GLR
GMF
PAF
NYC
NYCU
Lamps Installed
Asymmetric Wall Wash
Double Wall Wash
3-Wire Flex
4-Wire Flex
Emergency Battery Pack
(Use low profile only)
Fast Blow Fuse
Slow Blow Fuse
Paint After Fabrication
NYC Compliant
NYC Compliant, Union
Label
Accessories
(Order Separately)
FK22 2' 2' Flange Kit
FK24 2' 4' Flange Kit
FKCR Flange Kit Continuous
Row Connector
PRODUCT AVAILABILITY
2"
24"
BR22-2, BR24-2
LAMP TYPE
DEDICATED
LOUVERS
PERFORATED
PANELS
FIXTURE
HEIGHT
CEILING TYPE
2' 2'
2
3
14, 24
14, 24
2
3
3
2
2"
2"
G, SG
G, SG
2' 4'
2
3
28, 54
28, 54
2
3
3
2
2"
2"
G, SG
G, SG
2"
24"
BR22-3, BR24-3
16
NO. OF LAMPS IN
CROSS SECTION
SIZE
BR STRETTO
RECESSED ARCHITECTURAL
Ordering Information
BR
Model
BR Brio Stretto
4" T5 Low
Glare
Ceiling Type
GT Integral Cross Tee
no. of lamps
1 One
See Product Availability
table below.
SGT
Size
Lamp type
14
24
28
54
Accessories
(Order Separately)
FK042 4" 2' Flange Kit
FK044 4" 4' Flange Kit
FKCR Flange Kit
SM
SG
EP
Ballast
Voltage
U 120V-277V
347 347V
Options
F5830 30K 85CRI T5 or T5HO
Lamps Installed
Louver Finish
LS Low Iridescent Specular
MA Matte Anodized Low
Iridescent Semi-Specular
Aluminum
M4R 95% Reflective Specular
Aluminum
MW Matte White
GLR
GMF
PAF
NYC
NYCU
Lamps Installed
Asymmetric Wall Wash
Double Wall Wash
3-Wire Flex
Emergency Battery Pack
(Low profile)
Fast Blow Fuse
Slow Blow Fuse
Paint After Fabrication
NYC Compliant
NYC Compliant, Union
Label
Continuous Row
Connector
3"
PRODUCT AVAILABILITY
SIZE
NO. OF LAMPS IN
CROSS SECTION
LAMP TYPE
DEDICATED
LOUVERS
FIXTURE
HEIGHT
TRIM OPTIONS
(STANDARD BOLD)
4" 2'
14, 24
3"
GT, SGT, G, SM
4" 4'
28, 54
3"
GT, SGT, G, SM
3"
24"
4"
G
3"
48"
3"
3"
5"
GT
10"
2"
6"
SM
17
AC
Architectural Cove
RECESSED ARCHITECTURAL
Features
Ordering Information
AC
Model
AC Architectural
No. of lamps
4 Four
Cove
Ceiling
Compatibility
2' 2'
3' 3'
4' 4'
5' 5'
14", 26"
38" or 50"
Voltage
U 120V-277V
347 347V
inverted T-Bar)
F Overlap Flange Trim
(For hard ceilings)
Lamp Type
Ballast
Size
22
33
44
55
14
17
21
24
25
28
32
36
39
54
SIZE
3"
24", 36", 48" or 60"
O.A. Trim Type F
18
Custom trim
(optional)
Skirt Color
MW Matte White (Std.)
Options
EFH Extended Flange
Hanger (Minimum
2", maximum 4"
depth adjustment
GLR Fast Blow Fuse
GMF Slow Blow Fuse
Product Availability
9"
3"
14", 26"
38" or 50"
MW
9"
NO. OF
LAMPS
LAMP TYPE
SOCKET
TYPE
LAMP
DESCRIPTION
LAMP
LENGTH
2' 2'
36
2G11
Twin Tube
16"
3' 3'
14, 17, 24
Bi-pin
Programmed Start
2'
4' 4'
21, 25, 39
Bi-pin
Programmed Start
3'
5' 5'
28, 32, 54
Bi-pin
Programmed Start
4'
EMX
PA R A B O L I C S
Ordering Information
EMX
No. of lamps
2 Two
Ceiling Type
G Grid
Model
EMX EnergyMax
Energy Saving
Parabolic
M5
Lamp type
14 2', T5: 14 Watt
17 2', T8: 17 Watt
24 2', T5HO: 24
28
32
32U6
54
CELLS WIDE BY
CELLS LONG
Size
22 2' 2'
24 2' 4'
Louver
Finish
M5 MIRO-5
Watt
4', T5: 28 Watt
4', T8: 32, 30,
28 or 25 Watt
U-Bent, 6" Leg
Spacing T8: 32
Watt
4', T5HO: 54 or
51 Watt
See Product
Availability table
below.
CV
CD
CVD
H
HD
Options
PLUS30 30K 82CRI 28W T8
Lamps Installed1
AIR handling
S Static
A Air Handling
AV Air Handling
C
Accessories
(ORDER SEPARATELY)
FK24 2' 4' Flange Kit
FK22 2' 2' Flange Kit
FKCR Flange Kit Row Adaptor
Voltage
U 120V-277V
347 347V
w/Supply
Vanes
Combination
Supply/Extract
Combination
Supply Vanes/
Extract
Combination
Supply Extract
Dampers
Combination
Supply Vanes
Extract
Dampers
Heat Extract
Heat Extract
w/Dampers
Ballast
E Electronic T8, 0.88 Ballast Factor,
Instant Start
ESD115
Lamps Installed1
30K 82CRI T8
Lamps Installed
35K 82CRI T8
Lamps Installed
41K 82CRI T8
Lamps Installed
35K 85CRI T5
Lamps Installed
3-Wire Flex
4-Wire Flex
Emergency Battery
Pack
Fast Blow Fuse
Slow Blow Fuse
Four Bulk T-Bar
Clips
NYC Compliant
NYC Compliant,
Union Label
PRODUCT AVAILABILITY
SIZE
NO. OF
LAMPS
LAMP TYPE
LOUVER CONFIGURATIONS
2' 2'
2 3 (6), 3 3 (9)
2' 4'
28, 32, 54
2 6 (12)
5316"
31316"
4"
3"
24"
24"
EMX22-2
EMX24-2
19
P2
PA R A B O L I C S
Features
Ordering Information
p2
Model
P2 High
Efficiency
Static
Parabolic
Ceiling Type
No. of lamps
1
2
3
4
One
Two
Three
Four
See Product Availability
table below.
Size
94 9" 4'
14 1' 4'
22 2' 2'
24 2' 4'
G
F
M
SM
Grid
Overlap Flange
Modular Fit-in Trim
Surface Mount
(Static only)
Lamp type
17 2', T8: 17 Watt
28 4', T5: 28 Watt
31U1 U-Bent, 1" Leg
32
32U6
40TT
54
CELLS WIDE BY
CELLS LONG
AIR
FUNCTIONS
S Static
H Heat Extract
See Product
Availability
table below.
Louver Finish
LD Low Iridescent
Semi-Specular (Std.)
LS Low Iridescent
Specular
AIR CONTROL
Blank None
D Extract
Dampers
Ballast
NOTE: See Technical Section for other
ballast options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8, Instant Start
4E 4-Lamp Electronic T8, Instant Start
24E (1) 2-Lamp and (1) 4-Lamp
Electronic T8, Instant Start
EP Electronic T5 or T8, Programmed
Start
3EP 3-Lamp Electronic T5HO or T8,
Programmed Start
4EP 4-Lamp Electronic T5HO (N/A 347V)
or T8, Programmed Start
ETT Electronic Twin Tube, Instant Start
(Specify voltage)
Voltage
U 120V-277V
347 347V
Options
FO735 35K 75CRI T8 Lamps
Installed
Installed
Two Ballast Covers
3-Wire Flex
4-Wire Flex
Emergency Battery
Pack
GLR Fast Blow Fuse
GMF Slow Blow Fuse
MS9 Master/Satellite
w/9' Harness
PAF Paint After
Fabrication
For other options see pages
96-112.
2BC
C388
C488
EL
PRODUCT AVAILABILITY
5"
4"
24"
P224-2
5"
4"
24"
P224-3
5"
4"
24"
P224-4
20
NO. OF
LAMPS
LAMP TYPE
LOUVER CONFIGURATIONS
9" 4'
1
2
28, 32, 54
28, 32, 54
1 10 (10)
1 10 (10)
1' 4'
1
2
28, 32, 54
28, 32, 54
1 8 (8)
1 8 (8)
2' 2'
2
3
3 3 (9), 4 4 (16)
3 3 (9), 4 4 (16)
2' 4'
2
3
4
28, 32, 54
28, 32, 54
28, 32, 54
SIZE
P4
PA R A B O L I C S
Ordering Information
P4
Model
P4 Recessed
Air
Handling
Parabolic
No. of lamps
Ceiling Type
G Grid
F Overlap Flange
M Modular Fit-in
1
2
3
4
One
Two
Three
Four
See Product Availability
table below.
Trim
32
32U6
40TT
54
CELLS WIDE BY
CELLS LONG
See Product
Availability
table below.
SM Surface Mount
(Static only)
SG Slot Grid
Lamp type
17 2', T8: 17 Watt
28 4', T5: 28 Watt
31U1 U-Bent, 1"
Size
14 1' 4'
22 2' 2'
24 2' 4'
Louver Finish
GW Gloss White Enamel
LD Low Iridescent
Semi-Specular
LS Low Iridescent
Specular
MA Matte Anodized
Low Iridescent
Semi-Specular
Aluminum
AIR
FUNCTIONS
S Static
A Air Handling
C Combination
Supply/Extract
H Heat Extract
NO. OF
LAMPS
LAMP TYPE
Air control
Blank None
V Supply Vanes
D Extract Dampers
VD Vanes & Dampers
Voltage
U 120V-277V
347 347V
Options
FO735 35K 75CRI T8 Lamps
Installed
Installed
Ballast
Installed
Installed
Two Ballast Covers
3-Wire Flex
4-Wire Flex
Emergency Battery
Pack
GLR Fast Blow Fuse
GMF Slow Blow Fuse
M4R 95% Reflective
Specular Aluminum
Insert
MS9 Master/Satellite w/9'
Harness
PAF Paint After Fabrication
SRA Specular Anodized
Aluminum Reflector
NYC NYC Compliant
NYCU NYC Compliant, Union
Label
For other options see pages
96-112.
2BC
C388
C488
EL
10"
PRODUCT AVAILABILITY
SIZE
LOUVER CONFIGURATIONS
1' 4'
1
2
28, 32, 54
28, 32, 54
2' 2'
2
3
3 3 (9), 4 4 (16)
3 3 (9), 4 4 (16)
2' 4'
2
3
4
28, 32, 54
28, 32, 54
28, 32, 54
Standard louver configurations shown in bold. For other lamp or louver configurations,
contact your local Columbia Lighting representative. Various options may increase fixture
height on 2' 2' units. Contact your Columbia Lighting representative if plenum depth is a
concern.
5"
4"
24"
P424-2
14"
5"
4"
24"
P424-3
16"
5"
5"
4"
24"
P424-4
21
P4 Small Cell
PA R A B O L I C S
Features
Ordering Information
P4
Model
P4 Recessed Air
Handling
Small Cell
Parabolic
No. of lamps
2 Two
3 Three
4 Four
See Product
Availability
table below.
Ceiling Type
G Grid
F Overlap Flange
M Modular Fit-in
Trim
CELLS WIDE BY
CELLS LONG
See Product
Availability table
below.
SG Slot Grid
SM Surface Mount
Lamp type
17 2', T8: 17 Watt
28 4', T5: 28 Watt
31U1 U-Bent, 15/8"
32
32U6
40TT
54
Louver Finish
LD Low Iridescent
Semi-Specular
LS Low Iridescent
Specular
MA Matte Anodized
Low Iridescent
Semi-Specular
Aluminum
4"
24"
P424-3
4"
24"
P424-2
P424-4
22
AIR
FUNCTIONS
S Static
A Air Handling
C Combination
Supply/Extract
H Heat Extract
Ballast
NOTE: See Technical Section for other
ballast options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8, Instant
Start
4E 4-Lamp Electronic T8, Instant
Start
EP Electronic T5 or T8,
Programmed Start
3EP 3-Lamp Electronic T5HO or
T8, Programmed Start
4EP 4-Lamp Electronic T5HO (N/A
347V) or T8, Programmed
Start
ETT Electronic Twin Tube, Instant
Start (Specify voltage)
ELW Electronic T8, 0.77 Ballast
Factor, Low Wattage, Instant
Start
3ELW 3-lamp Electronic T8, 0.77
Ballast Factor, Low Wattage,
Instant Start
Options
FO735 35K 75CRI T8
Lamps Installed
Lamps Installed
Lamps Installed
Lamps Installed
Fabrication
Union Label
For other options see pages
96-112.
NO. OF
LAMPS
LAMP TYPE
LOUVER CONFIGURATIONS
2' 2'
2
3
6 6 (36), 7 7 (49)
6 6 (36), 7 7 (49)
2' 4'
2
3
4
28, 32, 54
28, 32, 54
28, 32, 54
6 13 (78), 7 15 (105)
6 13 (78), 7 15 (105)
6 13 (78), 7 15 (105)
SIZE
5"
Voltage
U 120V-277V
347 347V
PRODUCT AVAILABILITY
16"
5"
Air control
Blank None
V Supply Vanes
D Extract Dampers
VD Vanes & Dampers
(Static only)
Size
14 1' 4'
22 2' 2'
24 2' 4'
For other lamp or louver configurations, contact your local Columbia Lighting
representative. Various options may increase fixture height on 2' 2' units.
Contact your Columbia Lighting representative if plenum depth is a concern.
P4D
Shallow housing
Lightweight
PA R A B O L I C S
Ordering Information
P4D
Model
P4D High
Performance
Parabolic
No. of lamps
2 Two
3 Three
4 Four (N/A in
22)
See Product
Availability
table below.
Size
22 2' 2'3
24 2' 4'
Ceiling Type
G Grid
For hard ceilings, use
flange kit. See options
on page 105-106.
Lamp type
17 2', T8: 17 Watt
28 4', T5: 28 Watt
31U1 U-Bent, 15/8"
32
32U6
40TT
54
Louver Finish
LS Low Iridescent
Specular
MA Matte Anodized
Low Iridescent
Semi-Specular
Aluminum (Std.)
CELLS WIDE BY
CELLS LONG
Ballast
See Product
Availability table
below.
AIR Handling
S Static1
A Air Handling1
AV Air Handling with
1
Supply Vanes
C Combination
Supply/Extract2
CV Combination
CD
CVD
H
HD
Supply Vanes/
Extract2
Combination
Supply Extract
Dampers2
Combination
Supply Vanes
Extract Dampers2
Heat Extract2
Heat Extract with
Dampers2
Voltage
U 120V-277V
347 347V
Options
FO735 35K 75CRI T8 Lamps
Installed
Installed
Two Ballast Covers
3-Wire Flex
4-Wire Flex
Emergency Battery Pack
Fast Blow Fuse
Slow Blow Fuse
Master/Satellite w/9'
Harness
MS11 Master/Satellite w/ 11'
Harness
PAF Paint After Fabrication
TB4 (4) Bulk T-Bar Clips
For other options see pages
96-112.
2BC
C388
C488
EL
GLR
GMF
MS9
PRODUCT AVAILABILITY
NO. OF
LAMPS
LAMP TYPE
LOUVER CONFIGURATIONS
2' 2'
2
3
4
3 3 (9), 4 4 (16)
3 3 (9), 4 4 (16)
3 3 (9), 4 4 (16)
2' 4'
2
3
4
SIZE
513/16"
313/16"
24"
P4D22-2
1315/16"
47/8"
31/2"
24"
P4D24-3
23
NP
Narrow Parabolic
PA R A B O L I C S
Features
Ordering Information
NP
Model
NP Narrow
Parabolic
6" 2'
6" 3'
6" 4'
6" 6'
6" 8'
Lamp Type
17
25
28
32
Trim Type
FS Flush Steel Trim (G only)
FA Flush Trim (N/A Grid Trim)
RA 13/4" Regressed Trim
No. of Lamps
1 One
2 Two
SIZE
62
63
64
66
68
Ceiling Type
G Grid (For 1"
Voltage
U 120V-277V
347 347V
Shielding
LD Low Iridescent Semi-
inverted T-Bar)
F Overlap Flange
LS
WCB
A12
A19
OA
Ballast
Specular Parabolic
Louver
Low Iridescent Specular
Parabolic Louver
White Cross Baffle
Pattern 12 Acrylic Lens
Pattern 19 Acrylic Lens,
0.156" Nominal
Opal Acrylic Lens
Options
EL
GLR
GMF
NYC
NYCU
Row Configuration
SGL Single (Cross tee
installations only)
Accessories
(Order Separately)
116281 Yoke Hanger (Pair) One
Per (F) Trim Fixture
6"
Flush Grid
6"
6"
7"
5" Max.
3" Min.
6" R.O.
End View
Nominal
Side View
6" R.O.
6" O.A. Trim
Flush Flange
5"
6" R.O.
6" O.A. Trim
Regressed Flange
7"
Regressed Grid
24
VHC
PA R A B O L I C S
Ordering Information
94
Model
VHC Standard
VHC
PVHC 55 degree
Cutoff VHC
Louver Finish
LS Low
No. of lamps
1 One
2 Two1
Iridescent
Specular
Size
94 9" 4'
Lamp type
28 4', T5: 28 Watt
32 4', T8: 32, 30,
28 or 25 Watt
54 4', T5HO: 54 or
51 Watt
LS
Ceiling Type
GT Integral Cross-tee
F Overlap Flange
G Lay-in (GT is typically
CELLS WIDE BY
CELLS LONG
See Product
Availability table
below.
Air Function
S Static
H Heat Extract
(No dampers)
recommended)
SM Surface Mount
Voltage
U 120V-277V
347 347V
Distribution Options
Blank Symmetric Distribution
1WW Asymmetric Wall Wash
2WW Double Wall Wash
Ballast
NOTE: See Technical Section for
other ballast options.
E Electronic T8, Instant Start
EP Electronic T5 or T8,
Programmed Start
Options
FO735
FO835
F5835
EL
GLR
GMF
MSEE
NYC
NYCU
VHC only.
PRODUCT AVAILABILITY
MODEL
SIZE
NO. OF LAMPS
LAMP TYPE
LOUVER CONFIGURATIONS
VHC
9" 4'
1
2
28, 32, 54
28, 32, 54
1 13 (13)
1 13 (13)
PVHC
9" 4'
28, 32, 54
1 15 (15)
Type GT Integral cross-tee. Grid ends lay into standard T-Bar. Sides act as
integral cross tees to support tile. Fits standard 1" wide, 11/2" tall tee. Cut
ceiling tiles into two 73/8" strips.
6"
6"
8"
8"
9"
9"
VHC94-1 GT
VHC94-2 GT
25
HC
PA R A B O L I C S
Features
Ordering Information
HC
Model
HC Low Glare
No. of lamps
1 One
2 Two
3 Three
Parabolic
Size
14 1' 4'
22 2' 2'
24 2' 4'
Lamp type
28 4', T5: 28 Watt
31U1 U-Bent, 15/8"
32
32U6
40TT
54
Ceiling Type
CELLS WIDE BY
CELLS LONG
G
F
M
SG
SM
Grid
Overlap Flange
Modular Fit-in Trim
Slot Grid
Surface Mount*
*See limitations under
Product Availability in
the Product Selection
Guide.
AIR CONTROL
Blank None
V Supply Vanes
D Extract
See Product
Availability table
below.
Louver Finish
LD Low Iridescent
Semi-Specular (Std.)
Lamps Installed
Lamps Installed
PRODUCT AVAILABILITY
24"
NO. OF
LAMPS
LAMP TYPE
LOUVER
CONFIGURATIONS
LOUVER FINISH
1' 4'
1
2
28, 32, 54
28, 32, 54
1 12 (12)
1 12 (12)
LD, LS
LD, LS
12"
2' 2'
2
2*
2*
3
31U1, 40TT
40TT
32U6
31U1, 40TT
2 4 (8)
3 4 (12)
3 4 (12)
3 4 (12)
LD, LS
LD, LS
LD, LS
LD, LS
2' 4'
2
3
28, 32, 54
28, 32, 54
2 9 (18)
3 9 (27)
LD, LS
LD, LS
HC14-2 12 Cell
26
Lamps Installed
Options
FO735 35K 75CRI T8
FO835 35K 82CRI T8
Supply/Extract
SIZE
24"
Dampers
For information
about air handling
and controls, see
page 103.
H Heat Extract
7"
HC24-2 18 Cell
Voltage
U 120V-277V
347 347V
Dampers
Air Function
S Static
A Air Handling
C Combination
1"
61116"
VD Vanes &
6"
HC24-3 27 Cell
45
PA R A B O L I C S
Ordering Information
45
Model
45 Recessed
4" Deep
Cell
Parabolic
Size
14
22
24
44
1' 4'
2' 2'
2' 4'
Ceiling type
No. of lamps
G
F
M
SM
1
2
3
4
6
8
Grid
Overlap Flange
Modular Fit-in Trim
Surface Mount
(Static only)
SG Slot Grid
One
Two
Three
Four
Six
Eight
See Product Availability
table below.
Lamp type
17 2', T8: 17 Watt
28 4', T5: 28 Watt
31U1 U-Bent, 1" Leg
4' 4'
32
32U6
40TT
54
Cells wide by
cells long
See Product
Availability table
below.
Louver finish
LD Low Iridescent
LS Low Iridescent
Air function
S Static
A Air Handling
C Combination
MA Matte Anodized
H Heat Extract
Semi-Specular (Std.)
Specular
Supply/Extract
Air Control
V Supply Vanes
D Extract Dampers
VD Vanes &
Voltage
U 120V277V
347 347V
Dampers
Ballast
NOTE: See Technical Section for other
ballast options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8, Instant
Start
4E 4-Lamp Electronic T8, Instant
Start
24E (1) 2-Lamp and (1) 4-Lamp
Electronic T8, Instant Start
EP Electronic T5 or T8,
Programmed Start
3EP 3-Lamp Electronic T5HO or T8,
Programmed Start
4EP 4-Lamp Electronic T5HO (N/A
347V) or T8, Programmed Start
3ETT 3-Lamp Electronic Twin Tube,
Instant Start (Specify voltage)
For a specific ballast vendor show as
option.
T8 Lamps
Installed
FO835 35K 82CRI
T8 Lamps
Installed
F5835 35K 85CRI
T5 Lamps
Installed
2BC Two Ballast
Covers
C388 3-Wire Flex
C488 4-Wire Flex
EL Emergency
Battery Pack
GLR Fast Blow
Fuse
GMF Slow Blow
Fuse
MS9 Master/
Satellite
w/9' Harness
PAF Paint After
Fabrication
NYC NYC
Compliant
NYCU NYC
Compliant,
Union Label
For other options see
pages 96-112.
1"
PRODUCT AVAILABILITY
NO. OF
LAMPS
LAMP TYPE
LOUVER CONFIGURATIONS
1' 4'
1
2
28, 32, 54
28, 32, 54
1 6 (6), 1 9 (9)
1 6 (6), 1 9 (9)
2' 2'
2
3
3 3 (9), 4 4 (16)
3 3 (9), 4 4 (16)
2' 4'
2
3
4
28, 32, 54
28, 32, 54
28, 32, 54
4' 4'
6
8
28, 32, 54
28, 32, 54
6 6 (36), 8 8 (64)
6 6 (36), 8 8 (64)
SIZE
Options
FO735 35K 75CRI
Standard louver configurations shown in bold. For other lamp or louver configurations,
contact your local Columbia Lighting representative. Various options may increase
fixture height on 2' 2' units. Contact your Columbia Lighting representative if plenum
depth is a concern.
6"
6116"
24"
4524-2
6"
7"
12"
4514-2
6116"
24"
4524-3
6"
6116"
24"
4524-4
27
PW
PA R A B O L I C S
Features
Ordering Information
PW
Model
PW Parawash
Recessed
Wall Wash
LD
Ceiling Type
G Grid
SG Slot Grid
SM Surface Mount
No. of lamps
1 One
See Product
Availability table
below.
Aperture
K Kicker
B Cross Baffle
Voltage
U 120V-277V
347 347V
Options
EL Emergency Battery
Pack
Size
81 8" 1'
82 8" 2'
84 8" 4'
Lamp type
14 2', T5: 14 Watt
17 2', T8: 17 Watt
24 2', T5HO:
Reflector Finish
LD Low Iridescent SemiSpecular (Std.)
24 Watt
Ballast
Union Label
For other options see pages
96-112.
Compact, 2G11
Base: 40 Watt
54 4', T5HO: 54 or
51 Watt
Accessories
(Order Separately)
FK81 8" 1' Flange Kit
FK82 8" 2' Flange Kit
FK84 8" 4' Flange Kit
PRODUCT AVAILABILITY
4"
4"
8"
Twin Tube with
Cross Baffle
28
8"
Twin Tube with Kicker
SIZE
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS IN
UNIT
8" 2'
17, 40TT
1 9 (9)
8" 4'
1
1
1
2
28, 32, 54
40TT
1 18 (18)
1 18 (18)
LAMP TYPE
CROSS BAFFLE
CONFIGURATIONS
FW
Contractor friendly
PA R A B O L I C S
Ordering Information
FW
Model
FW Fluorescent
No. of Lamps
1 One
2 Two (Not available
Wall Wash
Ceiling Type
G Grid
SM Surface
in Twin Tube)
See Product Availability
table below.
Mount
(For hard ceiling
use flange kit.)
Reflector Finish
MA Matte Anodized Low
Voltage
U 120V-277V
347 347V
Options
EL Emergency
Battery Pack
MSEE Master/Satellite
End-To-End
SIZE
102 10" 2'
104 10" 4'
Lamp Type
Ballast
14
17
24
28
32
40TT
Union Label
For other options see pages
96-112.
Accessories
(Order Separately)
FK102 Flange Adaptor for
Hard Ceilings,
2' Fixture
FK104 Flange Adaptor for
Hard Ceilings,
4' Fixture
PRODUCT AVAILABILITY
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS IN
UNIT
LAMP TYPE
HEIGHT
LENGTH
10" 2'
1
2
1
2
49/16"
49/16"
24"
24"
10" 4'
1
1
2
1
2
2
49/16"
49/16"
49/16"
48"
48"
48"
SIZE
4916"
10"
FW Twin Tube
4916"
10"
FW 2T8
29
VC
Videoconference Luminaire
PA R A B O L I C S
Features
Ships separately
Ordering Information
VC
Model
VC Videoconference
Luminaire
Lens
VCL Black Cross Baffle
No. of lamps
2 Two
Length
12 1' 2'
14 1' 4'
Lamp type
17
28
32
54
Ballast
Voltage
U 120V-277V
347 347V
Options
C388 3-Wire Flex
C488 4-Wire Flex
GLR Fast Blow Fuse
GMF Slow Blow Fuse
NYC NYC Compliant
NYCU NYC Compliant,
Union Label
For other options see
pages 96-112.
PRODUCT AVAILABILITY
6"
48"
30
12"
VC12-2, VC14-2
SIZE
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS IN
UNIT
1' 2'
1' 4'
LAMP TYPE
WIDTH
LENGTH
HEIGHT
17
12"
24"
6"
28, 32, 54
12"
48"
6"
HH/HV
PA R A B O L I C S
Ordering Information
22
Model
HH Horizontal
Ceiling Type
F Flange
G Grid
Lamp type
P Pulse Start,
Lamp
Orientation
HV Vertical
Lamp
Orientation
Metal Halide
CELLS WIDE BY
CELLS LONG
See Product
Availability table
below.
Air Function
S Static
A Air Handling
Voltage
U 120V-277V
347 347V
480 480V
QT Quad-Tap,
120V, 208V,
240V, 277V
Lamp watts
175 175 Watt
200 200 Watt
250 250 Watt
320 320 Watt
350 350 Watt
400 400 Watt
Size
22 2' 2'
Louver Finish
LD Low Iridescent
Air control
Blank None
V Supply Vanes
Semi-Specular
LS Low Iridescent
Specular
Options
GLR
QR
NYC
NYCU
28916"
PRODUCT AVAILABILITY
SIZE
NO. OF LAMPS
LAMP TYPE
LAMP WATTAGE
LOUVER CONFIGURATIONS
2' 2'
3 3 (9), 4 4 (16)
28916"
If desired lamp or louver configuration is not shown above, contact your local
Columbia Lighting representative.
162532"
11"
11"
24" C-C Tees
HH22
31
4PS
LENSED TROFFERS
Features
Ordering Information
4PS
Model
4PS Specification
Grade Static
Troffer
SIZE
14 1' 4'
22 2' 2'
24 2' 4'
No. of Lamps
1
2
3
4
6
One
Two
Three (24 only)
Four (24 only)
Six (2x4 only)
See Product Availability
table below.
Ceiling type
G Inverted T-Bar
F Overlap Flange
M Modular
Door
FS
FA
RA
SFA
SRA
Lamp type
14 2', T5: 14 Watt
17 2', T8: 17 Watt
24
28
31U1
32
32U6
40TT
54
(2, 3, or 4 lamps)
2', T5HO: 24 Watt
4', T5: 28 Watt
U-Bent, 1" Leg Spacing
T8: 31 Watt (2 or 3 lamps)
4', T8: 32, 30, 28 or 25 Watt
U-Bent, 6" Leg Spacing
T8: 32 Watt (2 lamps)
Twin Tube Compact, 2G11
Base: 40 Watt (2 or 3 lamps)
4', T5HO: 54 or 51 Watt
Shielding
A12 Pattern 12 Acrylic Lens
A12125 Pattern 12 Acrylic Lense,
0.125" Nominal
0.156" Nominal
PC1 " " " Specular
Silver Polystyrene Louver
PC2 1" 1" 1" Specular
Silver Polystyrene Louver
For more shielding options see page 40.
Options
FO735 35K 75CRI T8 Lamps
Installed
Installed
EL Emergency Battery
Pack
(No Dampers)
Label
For more options see pages
96-112.
NO. OF
LAMPS
LAMP TYPE
GRID TRIM
HEIGHT*
FLANGE TRIM
HEIGHT*
1' 4'
1
2
3
28, 32, 54
28, 32, 54
28, 32, 54
5"
5"
5"
5"
5"
5"
2' 2'
2
3
4
4"
4"
4"
*
*
*
2' 4'
2
3
4
6
28, 32, 54
28, 32, 54
28, 32, 54
28, 32, 54
4"
4"
4"
4"
4"
4"
4"
4"
SIZE
4"
24"
4PS24-2
4"
24"
4PS24-3
4"
32
Voltage
U 120V-277V
347 347V
Product Availability
24"
4PS22-2
12"
4PS14-2
Ballast
4"
5"
24"
4PS24-4
*Some ceiling types and options may increase height of 2' 2' units.
Typically 4" high, some options may increase this to 6". Please
contact your Columbia Lighting representative for details.
ST8
LENSED TROFFERS
Ordering Information
ST8
Model
ST8 Low Profile
No. of Lamps
One
Two
Three
Four
Six
See Product Availability
table below.
SIZE
14 1' 4'
22 2' 2'
24 2' 4'
28
32
32U6
40TT
54
A12
A12125
A19
PC1
(14 only)
Lamp type
14
17
24
31U1
Shielding
Ceiling type
G Inverted T-Bar
F Overlap Flange
1
2
3
4
6
Specification
Troffer
NO. OF
LAMPS
LAMP TYPE
GRID TRIM
HEIGHT
1' 4'
1
2
3
32
28, 32, 54
32
4"
4"
4"
2' 2'
2
3
4
4"
4"
4"
2
3
4
6
28, 32, 54
28, 32, 54
28, 32, 54
28, 32, 54
3"
3"
3"
3"
2' 4'
Voltage
U 120V-277V
347 347V
Options
FO735 35K 75CRI T8
Lamps Installed
Lamps Installed
Lamps Installed
Door
Ballast
Aluminum
PS Premium Steel
Product Availability
SIZE
Lamps Installed
EL Emergency
Battery Pack
MS11 Master/Satellite
Pair w/ 11'
Harness
C388 3-Wire Flex
C488 4-Wire Flex
PAF Paint After
Fabrication
SLL Spring Loaded
Latches
NYC NYC Compliant
NYCU NYC Compliant,
Union Label
For more options see pages
96-112.
4"
4"
12"
ST814-2
24"
ST822-2
3"
3"
24"
ST824-3
24"
ST824-2
13"
5"
3"
2"
24"
ST824-4
33
JT8
LENSED TROFFERS
Features
Ordering Information
JT8
Model
JT8 Dedicated
No. of Lamps
2 Two
3 Three
4 Four (2 4 only)
T8 Lensed
Troffer
Ceiling type
G Inverted T-Bar
0.125" Nominal
A19 Pattern 19 Acrylic Lens,
0.156" Nominal
PC1 " " " Specular
Silver Polystyrene Louver
For more shielding options see page 40.
Lamp type
Door
Voltage
U 120V-277V
347 347V
Shielding
A12 Pattern 12 Acrylic Lens (Std.)
A12125 Pattern 12 Acrylic Lens,
SIZE
22 2' 2'
24 2' 4'
4 lamps)
U-Bent, 1" Leg
Spacing T8: 31 Watt (2
or 3 lamps)
4', T8: 32, 30, 28 or
25 Watt
U-Bent, 6" Leg
Spacing
T8: 32 Watt (2 lamps)
Twin Tube Compact,
2G11 Base: 40 Watt (2
or 3 lamps)
Aluminum
For more door options
contact factory.
Options
FO735 35K 75CRI T8
Lamps Installed
Lamps Installed
Lamps Installed
Lamps Installed
EL Emergency
Battery Pack
Ballast
w/9' Harness
MS11 Master/Satellite
w/ 11' Harness
Fabrication
SRA Specular
Reflector
For more options see
pages 96-112.
Product Availability
3"
4"
24"
JT822-2
24"
JT824-3
3"
3"
24"
JT824-2
34
24"
JT824-4
NO. OF
LAMPS
LAMP TYPE
GRID TRIM
HEIGHT
2' 2'
2
3
4
4"
4"
4"
2' 4'
2
3
4
32
32
32
3"
3"
3"
SIZE
WT
LENSED TROFFERS
Ordering Information
WT
Model
WT Wet Location
No. of Lamps
1
2
3
4
6
One
Two
Three
Four
Six
See Product Availability
table below.
Lensed
Troffer
SIZE
14 1' 4'
22 2' 2'
24 2' 4'
Ceiling type
G Inverted T-Bar
F Overlap Flange
Shielding
A12 Pattern 12 Acrylic Lens
A12125 Pattern 12 Acrylic Lens,
32
32U6
40TT
54
0.156" Nominal
Door
FA White Flush
Aluminum
RA White
Regressed
Aluminum
Product Availability
LAMP TYPE
GRID TRIM
HEIGHT
1' 4'
1
2
3
32
28, 32, 54
32
4"
4"
4"
2' 2'
2
3
4
4"
4"
4"
2
3
4
6
28, 32, 54
28, 32, 54
28, 32, 54
28, 32, 54
3"
3"
3"
3"
2' 4'
Ballast
NOTE: See Technical Section for other ballast
options.
E Electronic T8, Instant Start
3E 3-lamp Electronic T8, Instant Start
4E 4-Lamp Electronic T8, Instant Start
24E (1) 2-Lamp and (1) 4-Lamp
Electronic T8, Instant Start
EP Electronic T5 or T8, Programmed Start
3EP 3-lamp Electronic Programmed Start
(T8, T5HO) Others available.
4EP 4-Lamp Electronic T5HO (N/A 347V)
or T8, Programmed Start
EPTT Electronic Twin Tube,
Programmed Start
4"
NO. OF
LAMPS
SIZE
Voltage
U 120V-277V
347 347V
Lamp type
14
17
24
28
31U1
0.125" Nominal
11"
WT14-1
Options
FO735 35K 75CRI T8
Lamps Installed
Lamps Installed
Lamps Installed
4"
23"
WT22-2
3"
4"
23"
WT24-2
11"
WT14-2
3"
4"
11"
WT14-3
23"
WT24-3
35
5PA
LENSED TROFFERS
Features
Ordering Information
5PA
Model
5PA Specification
Grade Air
Handling
Troffer
No. of Lamps
Ceiling type
G Grid
1
2
3
4
6
One
Two
Three
Four
Six
See Product Availability
table below.
SIZE
14 1' 4'
22 2' 2'
24 2' 4'
Overlap
F Flange
M Modular
32
32U6
40TT
54
Air handling
S Static
RA White Regressed
A Return
H Heat Extract
C Combination
Aluminum
Aluminum
0.156" Nominal
PC1 " " " Specular
Silver Polystyrene Louver
PC2 1" 1" 1" Specular
Silver Polystyrene Louver
For more shielding options see
page 40.
Air Supply/
V Return Vanes
Heat Extract
D Dampers
VD Supply/
Return Vanes
& Heat Extract
Dampers
Ballast
NOTE: See Technical Section for other
ballast options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8,
Instant Start
4E 4-Lamp Electronic T8,
Instant Start
24E (1) 2-Lamp and (1) 4-Lamp
Electronic T8, Instant Start
EP Electronic T5 or T8,
Programmed Start
3EP 3-Lamp Electronic T5HO or T8,
Programmed Start
4EP 4-Lamp Electronic T5HO (N/A
347V) or T8, Programmed Start
ETT Electronic Twin Tube,
Instant Start
EPTT Electronic Twin Tube,
Programmed Start
24"
5PA24-3
24"
5PA22-2
4"
24"
5PA24-4
36
Options
FO735 35K 75CRI T8
Lamps Installed
Lamps Installed
Lamps Installed
EL Emergency
Battery Pack
Fabrication
Union Label
For more options see
pages 96-112.
NO. OF
LAMPS
LAMP TYPE
GRID TRIM
HEIGHT
1' 4'
1
2
3
28, 32, 54
28, 32, 54
28, 32, 54
5"
5"
5"
2' 2'
2
3
4
4"
4"
4"
2' 4'
2
3
4
6
28, 32, 54
28, 32, 54
28, 32, 54
28, 32, 54
4"
4"
4"
4"
SIZE
4"
4"
Voltage
U 120V-277V
347 347V
Product Availability
24"
5PA24-2
12"
5PA14-2
Air Supply/
Shielding
A12 Pattern 12 Acrylic Lens
A19 Pattern 19 Acrylic Lens,
Air control
Blank None
Supply/
Extract
4"
5"
Door
FA White Flush
Fit-in Trim
SG Slot Grid
Lamp type
14
17
24
28
31U1
4VS
LENSED TROFFERS
Ordering Information
4VS
Model
4VS Vandal
Resistant
Specification
Grade Troffer
No. of Lamps
2 Two
3 Three
4 Four
Ceiling type
G Grid
Overlap
F Flange
M Modular
Fit-in Trim
Voltage
U 120V-277V
347 347V
Door
FS Flush Steel
FA Flush Aluminum
To select the type
of screws in door
frame, see Tamper
Resistant Options at
right.
SIZE
14 1' 4'
22 2' 2'
24 2' 4'
Lamp type
14
17
24
28
31U1
32
32U6
40TT
54
Shielding
Product Availability
NO. OF
LAMPS
LAMP TYPE
GRID TRIM
HEIGHT*
1
2
3
28, 32, 54
28, 32, 54
28, 32, 54
5"
5"
5"
5"
5"
5"
2' 2'
2
3
4
*
*
*
*
*
*
2' 4'
2
3
4
6
28, 32, 54
28, 32, 54
28, 32, 54
28, 32, 54
4"
4"
4"
4"
4"
4"
4"
4"
1' 4'
Lens, Impact
Resistant, 0.140"
AT12 KSH Acri-Tuf, 0.140"
LG250 Polycarbonate
Acrylic Laminate
Lens, 0.250"
LG375 Polycarbonate
Acrylic Laminate
Lens, 0.375"
4"
FLANGE
TRIM
HEIGHT*
SIZE
Ballast
NOTE: See Technical Section for other
ballast options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8,
Instant Start
4E 4-Lamp Electronic T8,
Instant Start
24E (1) 2-Lamp and (1) 4-Lamp
Electronic T8, Instant Start
EP Electronic T5 or T8,
Programmed Start
3EP 3-Lamp Electronic T5HO or T8,
Programmed Start
4EP 4-Lamp Electronic T5HO (N/A
347V) or T8, Programmed Start
ETT Electronic Twin Tube,
Instant Start
EPTT Electronic Twin Tube,
Programmed Start
Options
FO735 35K 75CRI T8
Lamps Installed
Lamps Installed
Lamps Installed
EL Emergency
Battery Pack
MS9 Master/Satellite
w/9' Harness
Fabrication
Union Label
For more options see
pages 96-112.
5"
24"
4VS24-2
4"
12"
4VS14-2
4"
24"
4VS24-3
24"
4VS24-4
Variable*
24"
4VS22-2
*Some ceiling types and options may increase height of 2' 2' units.
Typically 4" high, some options may increase this to 6". Please
contact your Columbia Lighting representative for details.
37
M46
LENSED TROFFERS
Features
Ordering Information
M46
Model
M46 Specification
Grade
Circular
Regressed
Static Troffer
No. of Lamps
2
4
6
8
Two
Four
Six
Eight
See Product Availability
table below.
SIZE
2 2' Diameter
3 3' Diameter
4 4' Diameter
Ceiling type
F Overlap Flange
FS
OP
Door
FS White Flush
Shielding
OP Translucent
Steel (Std.)
Lamp Type
14
17
21
24
25
28
31U1
32
32U6
39
40TT
54
Voltage
U 120V-277V
347 347V
White Lens
Ballast
NOTE: See Technical Section for other
ballast options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8, Instant Start
4E 4-Lamp Electronic T8, Instant Start
24E (1) 2-Lamp and (1) 4-Lamp
Electronic T8, Instant Start
EP Electronic T5 or T8, Programmed Start
3EP 3-Lamp Electronic T5HO or T8,
Programmed Start
4EP 4-Lamp Electronic T5HO (N/A 347V)
or T8, Programmed Start
Options
EL Emergency
Battery Pack
Product Availability
NO. OF
LAMPS
LAMP TYPE
HEIGHT
2' Diameter
2
4
6
9"
9"
9"
3' Diameter
4
6
21, 25, 39
21, 25, 39
9"
9"
4' Diameter
4
6
8
28, 32, 54
28, 32, 54
28, 32, 54
9"
9"
9"
SIZE
9"
36"
38"
48"
50"
M462
M463
M464
38
HH/HV Lensed
Recessed HID Lensed Troffer
Features
LENSED TROFFERS
Ordering Information
22
Model
HH Horizontal
Lamp type
P Pulse Start
Lamp
Orientation
HV Vertical
Lamp
Orientation
Metal Halide
SIZE
22 2' 2'
Lamp watts
175 175 Watt
200 200 Watt
250 250 Watt
320 320 Watt
350 350 Watt
400 400 Watt1
Ceiling type
G Grid
F Flange
Shielding
TG73 Tempered Glass,
Pattern 73
CTGY12 Clear Tempered
Glass with A12
Underlay
DP Drop Polycarbonate
Lens2
Door
FS White Flush Steel
FA White Flush Aluminum
RA White Regressed
Aluminum
Voltage
347 347V
480 480V
QT Quad-Tap,
Air handling
S Static
Options
120V, 208V,
240V, 277V
GLR
QR
NYC
NYCU
Wired to
277 277V (Std.)
120 120V
208 208V
240 240V
4 00W horizontal positioned lamp listed for Marked Spacing only. See specification sheet for details.
Available with FS door only.
28916"
28916"
162532"
11"
11"
24" C-C Tees
HH22
39
Below are the door frames and lenses available for Columbia Lighting lensed troffers. The matrix identifies the availability of each option for
each specific troffer family. Other diffusers in addition to those listed below are available. Some restrictions apply.
Contact your local Columbia Lighting representative for information.
Availability Matrix
S - Standard
Door Frames
FS
FA
RA
BFS
BFA
BRA
SFA
SRA
Lenses
A12
A12125
A1212M
A12187
AT12
DR12
RF12
A15
A19
RF19
IMA
8224
8246
4PS
S
O
O
O
O
O
O
O
ST8
S
O
O
O
O
O
O
O
JT8
S
O
Description
Pattern 12 Acrylic
Pattern 12 Acrylic, 0.125" Nominal
Pattern 12 Acrylic, 0.125" Minimum
Pattern 12 Acrylic, 0.187" Nominal
KSH Acri-Tuf, 0.140"
Pattern 12 Acrylic, Impact Resistant, 0.125"
Pattern 12 Acrylic, Radio Frequency Suppressed
Pattern 15 Acrylic, 0.200" Nominal
Pattern 19 Acrylic, 0.156" Nominal
Pattern 19 Radio Frequency Suppressed
Injection Molded Acrylic, 0.150"
Holophane 8224
Holophane 8246
4PS
S
O
O
O
O
O
O
O
O
O
O
O
O
ST8
S
O
O
O
O
O
O
O
O
O
O
O
O
JT8
S
O
O
O
O
O
40
O
O
O
O
O
O
5PA
S
O
O
O
O
O
O
O
O
O
O
O
O
PM
S
O
O
O
O
O
O
O
O
O
O
O
O
SM
S
O
O
O
O
O
O
O
O
O
O
O
O
PM
Mitered corners
S U R FAC E
Ordering Information
PM
Model
PM Specification
Grade
Surface
Mount
No. of Lamps
Door
FS White Flush Steel
FA White Flush
2
3
4
6
Two
Three
Four
Six
See Product Availability
table below.
SIZE
14 1' 4'
22 2' 2'
24 2' 4'
Aluminum
RA White Regressed
Aluminum
Shielding
A12 Pattern 12 Acrylic Lens
A19 Pattern 19 Acrylic Lens,
0.156" Nominal
PC1 " " " Specular
Silver Polystyrene Louver
PC2 1" 1" 1" Specular
Silver Polystyrene Louver
For more shielding options see
pages 40.
Lamp Type
14
17
24
25
28
31U1
32
32U6
40TT
54
Voltage
U 120V-277V
347 347V
Ballast
NOTE: See Technical Section for other ballast
options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8, Instant Start
4E 4-Lamp Electronic T8, Instant Start
EP Electronic T5 or T8, Programmed Start
3EP 3-Lamp Electronic T5HO or T8,
Programmed Start
4EP 4-Lamp Electronic T5HO (N/A 347V) or
T8, Programmed Start
ETT Electronic Twin Tube, Instant Start
EPTT Electronic Twin Tube, Programmed Start
No. OF
LAMPS
LAMP TYPE
HEIGHT
1' 4'
2
3
28, 32, 54
28, 32, 54
3"
3"
2' 2'
2
3
4
3"
3"
3"
2' 4'
2
3
4
28, 32, 54
28, 32, 54
28, 32, 54
3"
3"
3"
Battery Pack
Union Label
For more options see
pages 96-112.
Product Availability
SIZE
Options
EL Emergency
3"
3"
24"
PM24-3
12"
PM14-2
3"
24"
PM24-2
3"
24"
PM24-4
41
SM
Surface Mount
S U R FAC E
Features
Low profile
Mitered corners
Ordering Information
SM
Model
SM Surface
No. of Lamps
2 Two
3 Three
4 Four
6 Six*
8 Eight*
Mount
Door
FS White Flush Steel
FA White Flush Aluminum
RA White Regressed
Aluminum
SIZE
14
22
24
44
1' 4'
2' 2'
2' 4'
4' 4'
Shielding
A12 Pattern 12 Acrylic Lens
A19 Pattern 19 Acrylic Lens,
Voltage
U 120V-277V
347 347V
0.156" Nominal
PC1 " " " Specular
Silver Polystyrene
Louver
PC2 1" 1" 1"
Specular Silver
Polystyrene Louver
For more shielding options see
pages 40.
32
32U6
40TT
54
Battery Pack
Lamp Type
14
17
24
28
31U1
Options
EL Emergency
Ballast
NOTE: See Technical Section for other ballast options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8, Instant Start
4E 4-Lamp Electronic T8, Instant Start
EP Electronic T5 or T8, Programmed Start
3EP 3-Lamp Electronic T5HO or T8, Programmed Start
4EP 4-Lamp Electronic T5HO (N/A 347V) or T8,
Programmed Start
EPTT Electronic Twin Tube, Programmed Start
Product Availability
3"
3"
24"
SM24-4
24"
SM24-2
SIZE
NO. OF LAMPS
LAMP TYPE
HEIGHT
1' 4'
2
3
28, 32, 54
28, 32, 54
3"
3"
2' 2'
2
3
4
3"
3"
3"
2' 4'
2
3
4
28, 32, 54
28, 32, 54
28, 32, 54
3"
3"
3"
4' 4'
4
6
8
28, 32, 54
28, 32, 54
28, 32, 54
4"
4"
4"
3"
24"
SM24-3
Note: SM 2' 2', 2' 4' and 4' 4' require four stems for
stem mounting.
42
WPM
S U R FAC E
Ordering Information
WPM
Model
WPM Specification
Grade Wall
Bracket
SIZE
2 2'
3 3'
4 4'
No. of Lamps
2 Two
See Product
Availability table
below.
Lamp Type
17 2', T8: 17 Watt
25 3', T8: 25 Watt
32 4', T8: 32, 30, 28
or 25 Watt
Ballast
NOTE: See Technical
Section for other ballast
options.
E Electronic T8,
Instant Start
EP Electronic T8,
Programmed Start
Voltage
U 120V-277V
347 347V
Options
EL Emergency Battery Pack
GCO Grounded Convenience
Outlet (120V only)
Product Availability
SIZE
No. OF
LAMPS
LAMP TYPE
Width
Length
HEIGHT
2'
17
79/16"
24"
4"
3'
25
79/16"
36"
4"
4'
32
79/16"
48"
4"
4"
79/16"
43
WAL
S U R FAC E
Features
Low profile
Ordering Information
WAL
Model
WAL Low
Profile
Wall
Mount
SIZE
2 2'
3 3'
4 4'
Lamp Type
2' T8: 17 Watt
3' T8: 25 Watt
4' T5: 28 Watt
4' T8: 32, 30, 28 or 25 Watt
Twin Tube Compact, 2G11
Base: 40 Watt (2' and 4'
units only, see table below)
54 4' T5HO: 54 or 51 Watt
Ballast
NOTE: See Technical Section for
other ballast options.
E Electronic T8, Instant Start
11E Two 1-Lamp Ballasts,
Instant Start
EP Electronic T5 or T8,
Programmed Start
EPTT Electronic Twin Tube,
Programmed Start
Downlight
1-Lamp Downlight
Downlight
See Product Availability
table below.
3"
44
7"
1"
3"
WAL4-1
Voltage
U 120V-277V
347 347V
17
25
28
32
40TT
No. of Lamps
1 1-Lamp, Downlight
2 2-Lamp, Downlight
1UD 1-Lamp, Uplight &
7"
3"
3"
WAL4-1UD
7"
7"
1"
WAL4-1U1D
7"
1"
Product Availability
No. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WAL2
1
2
1
2
17, 40TT
17, 40TT
WAL3
1
2
1
2
25
25
WAL4
1
2
1
2
1
2
2
4
28, 32, 54
28, 32, 54
40TT
40TT
SERIES
3"
WAL4-2
Options
EL
GCO
GLR
PSW
RSWD
WAL4-2UD
S U R FAC E
Ordering Information
Model
W Slim Wall
Mount
Light
SIZE
2 2'
3 3'
4 4'
No. of Lamps
1 One
2 Two
Lamp Type
Ballast
2', T5 14 Watt
2', T8: 17 Watt
3', T5: 21 Watt
2', T5HO: 24 Watt
3', T8: 25 Watt
4', T5: 28 Watt
4', T8: 32, 30, 28
or 25 Watt
39 3', T5HO: 39 Watt
54 4', T5HO: 54 Watt
14
17
21
24
25
28
32
See Product
Availability table
below.
Product Availability
NO. OF LAMPS
IN FIXTURE
LAMP TYPE
LAMP
LENGTH
WIDTH
LENGTH
HEIGHT
W2
1
2
1
2
14, 17, 24
14, 17, 24
2'
2'
4"
4"
24"
24"
4"
4"
W3
1
2
1
2
21, 25, 39
21, 25, 39
3'
3'
4"
4"
36"
36"
4"
4"
W4
1
2
1
2
28, 32, 54
28, 32, 54
4'
4'
4"
4"
48"
48"
4"
4"
Options
EL Emergency Battery Pack, T8
4ft only
Outlet
Less Switch
Paint After Fabrication
Pull Chain Switch (120V only)
18" Stem w/Canopy
18" 45 Swivel Stem w/Canopy
For more options see pages 96-112.
LSW
PAF
PSW
S18
SS18
71/16"
NO. OF LAMPS IN
CROSS SECTION
MODEL
Voltage
U 120V-277V
347 347V
4"
"
4"
4"
45
SA
S U R FAC E
Features
Ordering Information
SA
Model
SA Wall Mount
SIZE
2 2' (SA only)
3 3'
4 4'
Light
SAM (Includes
baffle for
directional
light)
No. of Lamps
1 One (SA only)
2 Two
See Product
Availability table
Below.
Lamp Type
17 2', T8: 17 Watt
(SA only)
Ballast
Voltage
U 120V-277V
347 347V
Options
4SW 4-Way Switch
EL Emergency Battery
Pack
28 or 25 Watt
Outlet
71/16"
71/16"
Product Availability
No. Of LAMPS IN
CROSS SECTION
No. Of
LAMPS IN
FIXTURE
LAMP
TYPE
LAMP
LENGTH
WIDTH
LENGTH
HEIGHT
SA2
1
2
1
2
17
17
2'
2'
71/16"
71/16"
24"
24"
4"
4"
SA3
1
2
1
2
25
25
3'
3'
71/16"
71/16"
36"
36"
4"
4"
SA4
1
2
1
2
32
32
4'
4'
71/16"
71/16"
48"
48"
4"
4"
SERIES
4"
4"
SA
71/16"
SA
"
71/16"
4"
SAM
46
SAM3
25
3'
71/16"
36"
4"
SAM4
32
4'
71/16"
48"
4"
PR
S U R FAC E
Ordering Information
PR
Model
PR Specification
SIZE
2 2'
3 3'
4 4'
Grade Bed
Light
No. of Lamps
1U1D 1-Lamp Uplight,
1-Lamp Downlight
1-Lamp Downlight
See Product Availability
table below.
Lamp Type
Ballast
NOTE: See Technical
17 2', T8: 17 Watt
Section for other ballast
25 3', T8: 25 Watt
options.
32 4', T8: 32, 30, 28
E Electronic T8,
or 25 Watt
Voltage
U 120V-277V
347 347V
Options
EL Emergency Battery Pack
GCO Grounded Convenience Outlet
(120V only)
Product Availability
No. OF
LAMPS
LAMP TYPE
Width
Length
HEIGHT
2'
2
3
17
17
79/16"
79/16"
24"
24"
4"
4"
3'
2
3
25
25
79/16"
79/16"
36"
36"
4"
4"
4'
2
3
32
32
79/16"
79/16"
48"
48"
4"
4"
SIZE
QCT
Quick-Change
Electrical Tray
4"
79/16"
PR1U1D
79/16"
PR2U1D
47
WM
S U R FAC E
Features
Ordering Information
WM
Model
WM Premium Wall/
Bed Light
SIZE
4 4'
Lamp Type
1D32 1-Down T8: 32 Watt
1U1D32 1-Up, 1-Down T8:
32 Watt, 2 Ballasts
1U2D32 1-Up, 2-Down T8:
32 Watt, 2 Ballasts
2D32 2-Down T8: 32 Watt
2U1D32 2-Up, 1-Down T8:
32 Watt, 2 Ballasts
Ballast
NOTE: See Technical Section
for other ballast options.
E Electronic Instant
Start (Std.)
Options
GCO Grounded Convenience Outlet
Voltage
U 120V-277V
(120V only)
Product Availability
513/16"
513/16"
9"
WM4-1D
513/16"
513/16"
9"
WM4-2U1D
513/16"
9"
WM4-1U2D
48
9"
WM4-1U1D
9"
WM4-2D
SERIES
LAMPS IN
CROSS SECTION
LAMPS IN
FIXTURE
LAMP
TYPE
LAMP
LENGTH
WIDTH
LENGTH
HEIGHT
WM4-1D
32
4'
9"
50"
513/16"
WM4-1U1D
32
4'
9"
50"
513/16"
WM4-2U1D
32
4'
9"
50"
513/16"
WM4-2D
32
4'
9"
50"
513/16"
WM4-1U2D
32
4'
9"
50"
513/16"
BIL
Bi-Level Luminaire
Features
Energy saving luminaire with integrated occupancy/
dissipation
S U R FAC E
photocell sensitivity
Ordering Information
BIL
Model
BIL Bi-Level
32
No. of Lamps in
Cross Section
Primary Ballast
NOTE: See Technical Section for other
ballast options.
EP Electronic T8, 0.88 Ballast Factor,
Programmed Start
EPLW Electronic T8, 0.77 Ballast Factor,
Low Wattage, Programmed Start
EPHL Electronic T8, 1.18 Ballast Factor,
High Light Output, Programmed
Start
2 Two
See Product Availability
table below.
Luminaire
SIZE
4 4'
Options
Voltage
U 120V-277V
FO730
FO735
FO830
FO835
EL
NYC
NYCU
Lamp type
32 4', T8: 32, 30, 28 or 25
Unoccupied
Occupied
Ballast Type
Watts
Lumens
Watts
Lumens
EP (0.88 BF)
EPLW (0.77 BF)
EPHL (1.18 BF)
15
15
15
989
989
989
74
62
90
4669
4208
5170
6"
Product Availability
SIZE
NO. OF
CONTROLLED
LAMPS
CONTROLLED
LAMP TYPE
NO. OF
CONSTANT
LAMPS
CONSTANT
LAMP TYPE
WIDTH
LENGTH
HEIGHT
4'
32
17
6"
54"
4"
4"
49
UC/UCS
S U R FAC E
Features
UC
Model
UC Undercabinet
SIZE
18 18"
24 24"
36 36"
48 48"
No. of Lamps
1 One
See Product
Availability
table below.
Lamp Type
15
17
20
25
30
32
Ballast
Voltage
U 120V-277V
Options
F0735 35K 75CRI T8 Lamps
Installed
Product Availability
1"
SERIES
SIZE
No. of LAMPS
IN FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
UC
18"
24"
36"
48"
1
1
1
1
15
17, 20
25, 30
32
5"
5"
5"
5"
18"
24"
36"
48"
1"
1"
1"
1"
5"
Ordering Information
UCS
Model
UCS Low Profile
Undercabinet
SIZE
12 12"
21 21"
24 24"
33 33"
42 42"
No. of Lamps
1 One
See Product
Availability
table Below.
Lamp Type
08 12" or 24", T5: 8 Watt
13 21" or 42", T5: 13 Watt
0813 33", T5: (1) 8 Watt, (1)
PH
120
Voltage
120 120V
Ballast
PH Preheat
Options
WSW On-Off Rocker Switch
GCO Grounded Convenience
Outlet
13 Watt
See Product Availability table
below for lamping options.
Installed
Product Availability
No. OF LAMPS
1"
5"
50
SERIES
SIZE
8W T5
UCS
12"
21"
24"
33"
42"
13W T5
1
2
1
1
2
WIDTH
LENGTH
HEIGHT
5"
5"
5"
5"
5"
12"
21"
24"
33"
42"
1"
1"
1"
1"
1"
MW/EW
WRAPS
Ordering Information
Model
Injection Molded Wrap
MWN 10" Narrow
MWW 15" Wide
Extruded Wrap
EWN 10" Narrow
EWW 15" Wide
SIZE
4 4'
8 8'
No. of Lamps in
Cross Section
2 Two
3 Three
4 Four
See Product
Availability table
below.
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28
or 25 Watt
54 4', T5HO: 54 or
51 Watt
Ballast
NOTE: See Technical Section for
other ballast options.
E Electronic Instant Start
(Std.)
3E 3-Lamp Electronic T8,
Instant Start
4E 4-Lamp Electronic T8,
Instant Start
EP Electronic T5 or T8,
Programmed Start
3EP 3-Lamp Electronic T5HO
or T8, Programmed Start
4EP 4-Lamp Electronic
T5HO (N/A 347V) or T8,
Programmed Start
Voltage
U 120V-277V
120 120V
347 347V
Options
EL Emergency Battery
Pack
Fluorescent Night
Light in G23 Base for
5W, 7W, 9W or GX23
Base for 13W. (120V
or 277V; Lamp not
included)
SB3 Stem Mounting
Bracket (Required for
3-Lamp units only)
NYC NYC Compliant
NYCU NYC Compliant, Union
Label
Accessories
(Order Separately)
S18 18" Stem w/Canopy
SS18 18" 45 Swivel Stem w/Canopy
CS-2 Ceiling Spacer
Product Availability
15"
SERIES
No. of lamps in
cross section
No. Of lamps
in fixture
Lamp Type
Lamp
length
WIDTH
LENGTH
HEIGHT
MWN4/EWN4
MWN8/EWN8
2
2
2
4
28, 32, 54
28, 32, 54
4'
4'
10"
10"
4'
8'
4"
4"
MWW4/EWW4
2
3
4
2
3
4
28, 32, 54
28, 32, 54
28, 32, 54
4'
4'
4'
15"
15"
15"
4'
4'
4'
4"
4"
4"
MWW8/EWW8
2
3
4
4
6
8
28, 32, 54
28, 32, 54
28, 32, 54
4'
4'
4'
15"
15"
15"
8'
8'
8'
4"
4"
4"
4"
MWW/EWW
10"
4"
MWN/EWN
51
WC
WRAPS
Features
Ordering Information
Model
WC 10" Wide
WCW 15" Wide
SIZE
2 2'
4 4'
8 8'
Voltage
U 120V-277V
120 120V
347 347V
See Product
Availability table
below.
3/32"
15/16"
2"
End
215/16"
15/16"
2"
End
WCW 215/16"
2-Lamp
15" Shielding w/Glow End
3/32"
15/16"
2"
End
WCW
3-Lamp 215/16"
15" Shielding w/Glow End
Options
EL
GLR
PAF
SB3
Accessories
(Order Separately)
S18 18" Stem w/Canopy
SS18 18" 45 Swivel Stem w/Canopy
Product Availability
52
Ballast
Lamp Type
14
17
24
28
32
No. of Lamps in
Cross Section
2 Two
3 Three
4 Four
WC
SERIES
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
LAMP
LENGTH
WIDTH
LENGTH
HEIGHT
WC2
WC4
WC8
2
2
2
2
2
4
14, 17, 24
28, 32, 54
28, 32, 54
2'
4'
4'
10"
10"
10"
2'
4'
8'
215/16"
215/16"
215/16"
WCW2
2
4
2
4
14, 17, 24
14, 17, 24
2'
2'
15"
15"
2'
2'
215/16"
215/16"
WCW4
2
3
4
2
3
4
28, 32, 54
28, 32, 54
28, 32, 54
4'
4'
4'
15"
15"
15"
4'
4'
4'
215/16"
215/16"
215/16"
WCW8
2
3
4
4
6
8
28, 32, 54
28, 32, 54
28, 32, 54
4'
4'
4'
15"
15"
15"
8'
8'
8'
215/16"
215/16"
215/16"
AW
WRAPS
Ordering Information
Model
AWN 85/16" Wide
AWW 14" Wide
SIZE
2 2' (AWN
only)
4 4'
8 8'
No. of Lamps in
Cross Section
2 Two
3 Three
4 Four
Lamp Type
17 2', T8: 17 Watt
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28
See Product
Availability table
below.
or 25 Watt
Product Availability
Ballast
NOTE: See Technical Section
for other ballast options.
E Electronic Instant
Start (Std.)
3E 3-Lamp Electronic T8,
Instant Start
4E 4-Lamp Electronic T8,
Instant Start
24E (1) 2-Lamp and (1)
4-Lamp Electronic T8,
Instant Start
EP Electronic T5 or T8,
Programmed Start
3EP 3-Lamp Electronic
T5HO or T8,
Programmed Start
4EP 4-Lamp Electronic
T5HO (N/A 347V) or
T8, Programmed Start
Voltage
U 120V-277V
347 347V
No. of lamps in
cross section
No. Of lamps
in fixture
Lamp Type
Lamp
length
WIDTH
LENGTH
HEIGHT
AWN2
AWN4
AWN8
2
2
2
2
2
4
17
28, 32, 54
28, 32, 54
2'
4'
4'
85/16"
85/16"
85/16"
2'
4'
8'
2"
2"
2"
AWW4
2
3
4
2
3
4
28, 32, 54
28, 32, 54
28, 32, 54
4'
4'
4'
14"
14"
14"
4'
4'
4'
225/32"
225/32"
225/32"
AWW8
2
3
4
4
6
8
28, 32, 54
28, 32, 54
28, 32, 54
4'
4'
4'
14"
14"
14"
8'
8'
8'
225/32"
225/32"
225/32"
Accessories
(Order Separately)
S18 18" Stem w/Canopy
SS18 18" 45 Swivel Stem w/Canopy
Ceiling
SERIES
Options
EL
GLR
PAF
SB3
1/16"
2"
Ceiling
AWN
85/16"
15/16"
225/32"
AWW
14"
3/32" Ceiling
15/16" 225/32" AWW
14"
53
AD
Corridor Light
WRAPS
Features
Slim design
Ordering Information
AD
Model
AD Corridor
SIZE
2 2'
3 3'
4 4'
Light
No. of Lamps in
Cross Section
1 One
2 Two
See Product
Availability table
below.
Lamp Type
Ballast
14
17
21
24
25
28
32
Voltage
U 120V-277V
347 347V
Options
EL Emergency Battery
Accessories
(Order Separately)
S18 18" Stem w/Canopy
SS18 18" 45 Swivel Stem w/Canopy
Product Availability
4"
4"
71/16"
"
4"
54
No. of LAMPS IN
CROSS SECTION
No. of
LAMPS IN
FIXTURE
LAMP TYPE
LAMP
LENGTH
WIDTH
LENGTH
HEIGHT
AD2
1
2
1
2
14, 17, 24
14, 17, 24
2'
2'
4"
4"
2'
2'
4"
4"
AD3
1
2
1
2
21, 25, 39
21, 25, 39
3'
3'
4"
4"
3'
3'
4"
4"
AD4
1
2
1
2
28, 32, 54
28, 32, 54
4'
4'
4"
4"
4'
4'
4"
4"
SERIES
PT
WRAPS
Ordering Information
PT
Model
PT Premium
Corridor
Wraparound
SIZE
2 2'
4 4'
8 8'
No. of Lamps in
Cross Section
1 One
2 Two
See Product
Availability table
below.
Lamp Type
Ballast
14
17
24
28
32
Voltage
U 120V-277V
347 347V
Options
EL Emergency Battery
Pack
Accessories
(Order Separately)
S18 18" Stem w/Canopy
SS18 18" 45 Swivel Stem w/Canopy
Product Availability
No. Of LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
PT2
1
2
PT4
PT8
SERIES
43/16"
LAMP TYPE
LAMP
LENGTH
WIDTH
LENGTH
HEIGHT
1
2
14, 17, 24
14, 17, 24
2'
2'
6"
6"
2'
2'
413/16"
413/16"
1
2
1
2
28, 32, 54
28, 32, 54
4'
4'
6"
6"
4'
4'
413/16"
413/16"
1
2
2
4
28, 32, 54
28, 32, 54
4'
4'
6"
6"
8'
8'
413/16"
413/16"
413/16"
27/16"
6"
55
RO
Corridor Wraparound
WRAPS
Features
Ordering Information
RO
Model
RO Corridor
Wraparound
SIZE
2 2'
4 4'
8 8'
No. of Lamps in
Cross Section
1 One
2 Two
See Product
Availability table
below.
Lamp Type
17 2', T8: 17 Watt
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28
or 25 Watt
43/16"
Ballast
27/16"
6"
56
Options
EL Emergency Battery Pack
GLR Fast Blow Fuse
PAF Paint After Fabrication
For more options and
accessories see pages 96-112.
Accessories
(Order Separately)
S18 18" Stem w/Canopy
SS18 18" 45 Swivel Stem w/Canopy
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
LAMP
LENGTH
WIDTH
LENGTH
HEIGHT
RO2
1
2
1
2
17
17
2'
2'
6"
6"
2'
2'
47/16"
47/16"
RO4
1
2
1
2
28, 32, 54
28, 32, 54
4'
4'
6"
6"
4'
4'
47/16"
47/16"
RO8
1
2
2
4
28, 32, 54
28, 32, 54
4'
4'
6"
6"
8'
8'
47/16"
47/16"
SERIES
47/16"
Voltage
U 120V-277V
347 347V
VL
WRAPS
Ordering Information
VL
Model
VL Vandal
Resistant
Wrap
SIZE
4 4'
No. of Lamps in
Cross Section
2 Two
See Product
Availability table
below.
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28
or 25 Watt
54 4', T5HO: 54 or
51 Watt
Ballast
NOTE: See Technical Section
for other ballast options.
E Electronic T8 Instant
Start
EP Electronic T5 or T8,
Programmed Start
Note: Certain non-standard
ballast cases may not fit
the VL. Contact factory for
details.
Voltage
U 120V-277V
347 347V
Options
GLR Fast Blow Fuse
WL Wet Location
(Ceiling only)
Accessories
(Order Separately)
VLSC Surface Conduit Entry Box
VLTS Tamper Resistant
Screwdriver
Note: Certain non-standard
ballast cases many not fit the VL.
Contact factory for details.
Product Availability
SERIES
No. of
lamps
LAMP type
WIDTH
LENGTH
HEIGHT
VL
28, 32, 54
9"
51"
3"
3"
9"
VL
1"
9"
VLSC Surface Conduit Entry Box
57
VR
WRAPS
Features
Ordering Information
VR
Model
VR Vandal
Resistant
Wraparound
WIDTH
N Narrow (51/8")
M Medium (85/16")
W Wide (125/16")
32
SIZE
4 4'
No. of Lamps
1
2
3
4
One (VRN)
Two (VRN, VRM)
Three (VRW)
Four (VRW)
See Product Availability
table below.
Lamp Type
32 4', T8: 32, 30,
28 or 25 Watt
Ballast
NOTE: See Technical
Section for other ballast
options.
E Electronic T8,
Instant Start
3E 3-Lamp Electronic
T8, Instant Start
4E 4-Lamp Electronic
T8, Instant Start
Voltage
U 120V-277V
347 347V
OPTIONS
EL Emergency
Battery
Pack
NYC NYC
Compliant
NYCU NYC
Compliant,
Union
Label
Accessories
(Order Separately)
VDR
GLRK
S18
SS18
Product Availability
23/4"
33/4"
No. of
lamps
Lamp Type
WIDTH
LENGTH
HEIGHT
4' VRN
1
2
32
32
51/8"
51/8"
48"
48"
33/4"
33/4"
4' VRM
32
85/16"
48"
23/4"
4' VRW
3
4
32
32
125/16"
125/16"
48"
48"
23/4"
23/4"
Size
125/16"
VRW 3-Lamp
51/8"
VRN
23/4"
23/4"
85/16"
VRM
58
125/16"
VRW 4-Lamp
LHV
INDUSTRIALS
ambient operation
Ordering Information
LHV
SIZE
4 4'
No. of Lamps
4 Four
6 Six
8 Eight
Model
LHV VersaBay
Fluorescent
High Bay
Reflector
M4R 95% Reflective
Specular Aluminum
(Narrow Beam)
GW Gloss White (Wide Beam)
Lamp Type
32 4', T8: 32, 30,
28 or 25 Watt
51, or 49 Watt
uplight
ST Solid Top
U Uplight
Voltage
U 120V-277V
347 347V
480 480V
Lamps installed
T8
FO730 3000K 75CRI
LHV4-454
FO735 3500K 75CRI
4EP (1) 4-Lamp Electronic T5HO,
FO741 4100K 75CRI
Programmed Start
FO750 5000K 75CRI
LHV4-654
T5HO
24EP (1) 2-Lamp and (1) 4-Lamp
Electronic T5HO, Programmed Start
F5830 3000K 85CRI
3EP (2) 3-Lamp and Electronic T5HO,
F5835 3500K 85CRI
Programmed Start
F5841 4100K 85CRI
LHV4-854
F5850 5000K 85CRI
(2)
4-Lamp
Electronic
T5HO,
4EP
Programmed Start
F5865 6500K 85CRI
LHV4-432
F51830 3000K 85CRI 51W
4EHL (1) 4-Lamp Electronic T8,
F51835 3500K 85CRI 51W
High Light Output, Instant Start
4100K 85CRI 51W
EPHL (2) 2-Lamp Electronic T8, High Light F51841
F51850 5000K 85CRI 51W
Output, Programmed Start
4EPHL (1) 4-Lamp Electronic T8, High Light F51865 6500K 85CRI 51W
Output, Programmed Start
F49830 3000K 85CRI 49W
LHV4-632
F49835 3500K 85CRI 49W
3EHL (2) 3-Lamp Electronic T8,
F49841 4100K 85CRI 49W
High Light Output, Instant Start
F49850 5000K 85CRI 49W
24EHL (1) 2-Lamp and (1) 4-Lamp
Electronic T8, High Light Output,
F49865 6500K 85CRI 49W
Ballast
Options
C6TL15_ 6' Cord and Twist-Lock Plug 15A
(Add Voltage: 1=120, 2=277)
ODS2
Instant Start
LHV4-832
4EHL (2) 4-Lamp Electronic T8, High Light
Output, Instant Start
ODS480
SP
WG
NYC
NYCU
120V
Clear Acrylic Lens2
Clear Polycarbonate Lens2
Clear Acrylic Lens and Flat Wire Guard2
Clear Polycarbonate Lens and Flat Wire
Guard2
1100-1400 Lumens, T8 1-Lamp
725-1250 Lumens, T5HO 1-Lamp
4-Conductor Cord
Fast Blow Fuse
Factory Installed Occupancy Sensor,
120/277/347V, One Relay, All Lamps
On/Off1
Factory Installed Occupancy Sensor,
120/277/347V, Two Relay, Two Ballasts
Controlled Separately1
Factory Installed Occupancy Sensor,
480V, One Relay, All Lamps On/Off1
Factory Installed Occupancy Sensor
with Daylight Harvesting Photosensor,
120/277/347V, One Relay, All Lamps
On/Off1
Factory Installed Occupancy Sensor
with Daylight Harvesting Photosensor,
120/277/347V, Two Relay, Two Ballasts
Controlled Separately1
Factory Installed Occupancy Sensor with
Daylight Harvesting Photosensor, 480V,
One Relay, All Lamps On/Off1
Side Panels Installed2
Flat Wire Guard2
NYC Compliant
NYC Compliant, Union Made
Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories see page 98.
Side panels increase height to 2".
Product Availability
MODEL
SOURCE
NO. OF
LAMPS
UPLIGHT
OPTIONS
LAMP
TYPE
WIDTH
LENGTH
HEIGHT2
LHV4
T5HO, T8
T5HO, T8
T5HO, T8
4
6
8
U, ST
U, ST
U, ST
32, 54
32, 54
32, 54
163/16"
205/8"
25"
48"
48"
48"
2"
2"
2"
59
LHV/LHA
Shielding System
Features
2
INDUSTRIALS
Ordering Information
2. The end jaw securely attaches to the end cap and side
panels. Each end jaw rotates for easy access to the lens
and wire guard but locks in place when returned to its
closed position. Once in place, the lens and wire guard is
supported on all four sides.
2"
4-Lamp
163/16"
2"
20"
6-Lamp
2"
25"
8-Lamp
3. The end jaw rotates down without the use of any tools.
163/16"
2"
4-Lamp
20"
2"
6-Lamp
25"
2"
8-Lamp
4. The lens or wire guard simply slides out once jaw is rotated.
LHV
Model
Shielding
S Shielding
LHV VersaBay
Fluorescent
High Bay
No. of Lamps In
Cross Section
4 Four
6 Six
8 Eight
Shielding1
CA Clear Acrylic Lens
CP Clear Polycarbonate Lens
CAWG Clear Acrylic Lens and Flat
Wire Guard
60
LHV*SPJ
LHV*FWG
LHV*CA
LHV*CP
LHA
INDUSTRIALS
Ordering Information
LHA
SIZE
4 4'
Lamp Type
32 4', T8: 32
Watt
54 4', T5HO: 54
uplight
ST Solid Top
U Uplight
Ballast Factor
BLANK 0.88BF for T8, 1.00BF
for T5HO
Watt
Model
LHA Industrial
Reflector
N Narrow Distribution
W Wide Distribution
Fluorescent
High Bay
No. of Lamps
4 Four
6 Six
Accessories (order separately)
LHVTH Tong Hanger (Pair)
LHVWG4-4 Wireguard, White,
LHVWG4-6
LHVWG4-8
LHVQM5
LHVQM10
LHVSPM5
LHVSP
LHVOS480
LHVOS1
LHVOS2
C6TL15-120
C6TL15-277
C6P15-120
4-Lamp Fixture
Wireguard, White,
6-Lamp Fixture
Wireguard, White,
8-Lamp Fixture
Aircraft Cable, 5' (Pair)
Aircraft Cable, 10' (Pair)
Single Point Mounting,
Includes Pair of 5' Aircraft
Cables
Side Panels (Pair)
Occupancy Sensor1,
480V, One Relay
Occupancy Sensor1,
120/277/347V, One Relay
Occupancy Sensor1,
120/277/347V, Two Relays
Cord and Plug Kit (white),
6 ft., Twist Lock NEMA
L5-15P, 15 amp, 120V
Cord and Plug Kit (white),
6 ft., Twist Lock NEMA
L7-15P, 15 amp, 277V
Cord and Plug Kit (white),
6 ft., Straight Blade NEMA
5-15P, 15 amp, 120V
Ballast
LHA4-454
EP (2) 2-Lamp Electronic T5HO,
Programmed Start
4EP (1) 4-Lamp Electronic T5HO,
Programmed Start
LHA4-432
E (2) 2-Lamp Electronic T8, Instant
Start
Start
4EP (1) 4-Lamp Electronic T8,
Programmed Start
LHA4-654
24EP (1) 2-Lamp & (1) 4-Lamp
Options
C6TL15_ 6' Cord and Twist-Lock Plug 15A
Voltage
U 120V-277V
347 347V
480 480V
Lamps installed
T8
FO835 32 Watt, 82 CRI,
3500K
4100K
FO850 32 Watt, 82 CRI,
5000K
T5HO
F554835 54 Watt, 85 CRI,
3500K
LHA4-632
3E (2) 3-Lamp Electronic T8, Instant
Start
3EP (2) 3-Lamp Electronic T8,
Programmed Start
24E (1) 2-Lamp & (1) 4-Lamp
Electronic T8, Instant Start
24EP (1) 2-Lamp & (1) 4-Lamp
Electronic T8, Programmed Start
OS480
ODS1
ODS2
ODS480
Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight
harvesting sensor accessories see page 98.
2
Side panels increase height to 2".
Guard2
Clear Polycarbonate Lens and Flat
Wire Guard2
Side Panels Installed2
Flat Wire Guard2
Top Cover
1100-1400 Lumens, T8 1-Lamp
725-1250 Lumens, T5HO 1-Lamp
3-Conductor Cord
4-Conductor Cord
Factory Installed Occupancy
Sensor, 120/277/347V, One
Relay, All Lamps On/Off1
Factory Installed Occupancy
Sensor,
120/277/347V, Two Relay, Two
Ballasts Controlled Separately1
Factory Installed Occupancy
Sensor, 480V, One Relay, All
Lamps On/Off1
Factory Installed Occupancy
Sensor with Daylight Harvesting
Photosensor, 120/277/347V, One
Relay, All Lamps On/Off1
Factory Installed Occupancy
Sensor with Daylight Harvesting
Photosensor, 120/277/347V, Two
Relay, Two Ballasts Controlled
Separately1
Factory Installed Occupancy
Sensor with Daylight Harvesting
Photosensor, 480V, One Relay, All
Lamps On/Off1
Product Availability
MODEL
SOURCE
NO. OF
LAMPS
UPLIGHT
OPTIONS
LAMP
TYPE
WIDTH
LENGTH
HEIGHT2
LHA
T5HO, T8
T5HO, T8
4
6
U, ST
U, ST
32, 54
32, 54
163/16"
205/8"
48"
48"
2"
2"
61
LHR
INDUSTRIALS
Employs T5 or T8 technology
Efficiency up to 99.3%
Ordering Information
LHR
Model
LHR Ultra-
No. of Lamps
4 Four
6 Six
Efficient
Fluorescent
High Bay
SIZE
4 48"
(Nominal)
Reflector
M4R 95% Reflective
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30,
Specular Aluminum
(Narrow Beam)
LS Specular Anodized
Aluminum
(Narrow Beam)
GW Gloss White Powder
Coat (Wide Beam)
uplight
ST Solid Top
Voltage
U 120V-277V
347 347V
480 480V
(No uplight)
U Uplight,
12%
Options
F5830
F5835
F5841
F5850
FO830
F0835
F0841
LHHB
C6TL15_
28 or 25 Watt
54 4', T5HO: 54
or 51 Watt
Ballast
NOTE: See Technical Section for other ballast options.
LHR4-454
EP (2) 2-Lamp Electronic T5HO, Programmed Start
4EP (1) 4-Lamp Electronic T5HO, Programmed Start
LHR4-654
EP (3) 2-Lamp Electronic T5HO, Programmed Start
3EP (2) 3-Lamp Electronic T5HO, Programmed Start
24EP (1) 2-Lamp and (1) 4-Lamp Electronic T5HO, Programmed
Start
LHR4-432
E (2) 2-Lamp Electronic T8, Instant Start
EP (2) 2-Lamp Electronic T8, Programmed Start
4E (1) 4-Lamp Electronic T8, Instant Start
4EP (1) 4-Lamp Electronic T8, Programmed Start
LHR4-632
3E (2) 3-Lamp Electronic T8, Instant Start
3EP (2) 3-Lamp Electronic T8, Programmed Start
24E (1) 2-Lamp and (1) 4-Lamp Electronic T8, Instant Start
24EP (1) 2-Lamp & (1) 4-Lamp Electronic T8, Programmed Start
3EHL (2) 3-Lamp Electronic T8, High Light Output, Instant Start
Product Availability
21116"
17"
LHR4-4
4"
SOURCE
NO. OF
LAMPS
UPLIGHT
OPTIONS
LAMP TYPE
WIDTH
LHR4-4
T5, T8
ST, 6, 12
28, 32, 54
LHR4-6
T5, T8
ST, 6, 12
28, 32, 54
LENGTH
HEIGHT
173/18"
48"
211/16"
243/16"
48"
4"
Note: Not intended for surface mounting. Provide a minimum of 3" clearance.
24316"
LHR4-6
62
MODEL
LHR Narrow
Narrow Fluorescent High Bay
Features
Ordering Information
LHR
Model
LHR Narrow
No. of Lamps
2 Two
3 Three
Fluorescent
High Bay
Reflector
M4R 95% Reflective
Specular Aluminum
LS Specular Anodized
uplight
U 15% Uplight
ST Solid Top
Aluminum
Voltage
U 120V-277V
347 347V
480 480V
SIZE
4 48"
8 96"
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28 or
25 Watt
Accessories
GLH5
GLH10
GLH15
LHRNWG
OS1K
Ballast
NOTE: See Technical Section for other ballast options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8, Instant Start
24E (1) 2-Lamp and (1) 4-Lamp Electronic T8,
Instant Start
3EHL 3-Lamp Electronic T8, 1.2 Ballast Factor,
High Light Output, Instant Start
EP Electronic T5 or T8, Programmed Start
3EP 3-Lamp Electronic T5HO (or T8), Programmed
Start
24EP (1) 2-Lamp and (1) 4-Lamp Electronic T5HO
or T8, Programmed Start
Options
F0841 41K 82CRI 32W T8 Lamps Installed
F5841 41K 85CRI T5 or T5HO Lamps
Installed
to Fixture
Fast Blow Fuse
White Cross Baffle
NYC Compliant3
NYC Compliant, Union Label3
For more options see Technical Section.
GLR
WCB
NYC
NYCU
Product Availability
NO. OF LAMPS
IN CROSS
SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
LHR4
2
3
2
3
28, 32, 54
28, 32, 54
9"
9"
481/16"
481/16"
411/16"
411/16"
LHR8
2
3
4
6
28, 32, 54
28, 32, 54
9"
9"
961/16"
961/16"
411/16"
411/16"
MODEL
41116"
9"
LHR4-332
63
LHC
INDUSTRIALS
Ordering Information
LHC
Model
LHC Enclosed and
Gasketed
Linear High
Bay
No. of Lamps
4 Four
6 Six
See Product Availability
table below.
Door style
FA White Flush
Aluminum
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30,
28 or 25 Watt
54 4', T5HO: 54
or 51 Watt
ACCESSORIES
(order separately)
LHHB Universal Hanger Bracket Kit
Steel Door
Shielding
Options
Ballast
Clear Acrylic
Clear Polycarbonate
Pattern 12 Acrylic Lens
Pattern 12 Acrylic Lens
0.0125" Nominal
A15 Pattern 15 Acrylic Lens,
0.200" Nominal
A19 Pattern 19 Acrylic Lens,
0.156" Nominal
Voltage
U 120V-277V
347 347V
480 480V
Specular Aluminum
(S/MH = 1.0)
LS Specular Anodized
Aluminum
(S/MH = 1.0)
GW Gloss White Powder
Coat (S/MH - 1.4)
CA
CP
A12
A12125
Reflector
M4R 95% Reflective
Stainless Steel
Door
SIZE
164 16" 4'
24 2' 4'
FO730
FO735
FO741
FO830
F5835
Product Availability
5"
5"
24"
LHC24
64
16"
LHC164
MODEL
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
LHC164
28, 32, 54
16"
48"
5"
LHC24
28, 32, 54
24"
48"
5"
LHE
Efficiency up to 95%
INDUSTRIALS
Ordering Information
LHE
Model
LHE Efficient
SIZE
4 48"
8 96"
High Bay
(LHEM only)
No. of Lamps
2 Two (LHEM only)
4 Four
6 Six (LHEW only)
See Product
Availability table
below.
BODY
M Medium Body, 91516"
W Wide Body, 15516"
LHHB
GLH5
GLH10
GLH15
LHTF
LHTWCB
LHEMWG
LHEWWG
LHEMCG
LHEWCG
OS1K
Shielding
Blank None
WCB White Steel Cross
uplight
ST Solid Top
(No uplight)
Baffle*
PA Prismatic Acrylic
Wraparound Lens*
*N/A with wire guard. May
be used with cage guard.
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28 or 25 Watt
54 4', T5HO: 54 or 51 Watt
ACCESSORIES
(order separately)
U Uplight
Voltage
U 120V-277V
347 347V
480 480V
Options
Ballast
NOTE: See Technical Section for other ballast
options.
E Electronic T8, Instant Start
3E 3-Lamp Electronic T8, Instant Start
4E 4-Lamp Electronic T8, Instant Start
24E (1) 2-Lamp and (1) 4-Lamp Electronic
T8, Instant Start
3EHL 3-Lamp Electronic T8, 1.2 Ballast Factor,
High Light Output, Instant Start
EP Electronic T5 or T8, Programmed Start
3EP 3-Lamp Electronic T5HO (6-Lamp only)
or T8, Programmed Start
4EP 4-Lamp Electronic T5HO or T8,
Programmed Start
24EP (1) 2-Lamp and (1) 4-Lamp Electronic
T5HO or T8, Programmed Start
F5830
F5835
F5841
F5850
C6TL15_
Use programmed start ballast. Not recommended for use with instant start.
For more occupancy/daylight harvesting sensor accessories see page 98.
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
LHEM4
2
4
2
4
28,32, 54
28, 54
915/16"
915/16"
48"
48"
2"
2"
LHEM8
2
4
4
8
28,32, 54
28, 54
915/16"
915/16"
96"
96"
2"
2"
LHEW4
4
6
4
6
28, 32, 54
28, 32, 54
155/16"
155/16"
48"
48"
2"
2"
MODEL
2"
2"
91516"
LHEM
15516"
LHEW 6-Lamp
2"
15516"
LHEW 4-Lamp
65
LHG
INDUSTRIALS
Ordering Information
LHG
24
Model
LHG Recessed
Fluorescent
High Bay
No. of Lamps in
cross section
4 Four
6 Six
See Product
Availability table
below.
SIZE
24 2' 4'
Ceiling Type
G Inverted T-Bar
F Flange
M Fit-In Trim
SM Surface Mount
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30,
28 or 25 Watt
54 4', T5HO: 54
or 51 Watt
Door style
Blank None
FS Flush Steel
FA Flush
Aluminum
RA Regressed
Aluminum
Reflector
M4R 95% Reflective
A12125
A15
A19
Voltage
U 120V-277V
347 347V
480 480V
Specular Aluminum
(S/MH = 1.0)
LS Specular Anodized
Aluminum
(S/MH = 1.0)
GW Gloss White Powder
Coat (S/MH - 1.4)
Shielding
Blank
CA
CP
CAWG
CPWG
ACCESSORIES
(order separately)
OS1K Occupancy Sensor Kit,
Lamps Installed
Lamps Installed
F5835
T8
E (2) 2-Lamp Electronic T8, Instant Start
EP (2) 2-Lamp Electronic T8, Programmed Start
EHL (2) 2-Lamp Electronic T8 High Light Output,
Instant Start
F5841
F5850
EL
Instant Start
Instant Start
24E (1) 2-Lamp and (1) 4-Lamp Electronic T8,
Instant Start
24EP (1) 2-Lamp and (1) 4-Lamp Electronic T8,
Programmed Start
24EHL (1) 2-Lamp and (1) 4-Lamp Electronic T8 High
Light Output, Instant Start
Lamps Installed
Ballast
None
Clear Acrylic
Clear Polycarbonate
Clear Acrylic with
White Wire Guard
Clear Polycarbonate with
White Wire Guard
Pattern 12 Acrylic Lens,
0.125" Nominal
Pattern 15 Acrylic Lens,
0.200" Nominal
Pattern 19 Acrylic Lens,
0.156" Nominal
Options
FO730 30K 75CRI T8
GLR
PAF
or T5HO Lamps
Installed
35K 85CRI T5
or T5HO Lamps
Installed
41K 85CRI T5
or T5HO Lamps
Installed
50K 82CRI T5HO
Lamps Installed
Emergency
Battery Pack
(Not available
for wet
locations)
Fast Blow Fuse
Paint After
Fabrication
T5HO
EP (2 or 3) 2-Lamp T5 or (2) 2-Lamp T5HO,
Programmed Start
*Use programmed start ballast. Not recommended for use with instant start.
For more occupancy/daylight harvesting sensor accessories see page 98.
1
Only to be used in surface mount applications.
Programmed Start
Product Availability
5"
5"
24"
LHG24-6
Surface
66
24"
LHG24-6
Recessed
MODEL
NO. OF
LAMPS
LAMP TYPE
WIDTH
LENGTH
HEIGHT
LHG
28, 32, 54
24"
48"
5"
LHG
28, 32, 54
24"
48"
5"
LHB
Optional uplight
INDUSTRIALS
Ordering Information
LHB
Model
LHB High-
Performance
Shielded
High Bay
No. of Lamps
2 Two
Louver finish
M4R 95% Reflective
Voltage
U 120V-227V
347 347V
U Uplight 15%
Aluminum
or 25 Watt
54 4', T5HO: 54 Watt
(No uplight)
MA Matte Anodized
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28
uplight
ST Solid Top
Specular Aluminum
See Product
Availability
table below.
SIZE
4 48" (Nominal)
8 96" (Nominal)
Cell configuration
26 2 Cells Wide by 6
Cells Long (4')
Ballast
NOTE: See Technical Section for other
ballast options.
E Electronic T8, Instant Start
EP Electronic T5,
Programmed Start
4EP 4-Lamp Electronic T5HO (N/A
347V)
ACCESSORIES
(Order separately)
LHTF
GLH5
GLH10
GLH15
OS1K
Options
FO830
FO835
FO841
F5830
Use programmed start ballast. Not recommended for use with instant start.
For more occupancy/daylight harvesting sensor accessories see page 98.
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS
IN FIXTURE
LAMP
TYPE
WIDTH
LENGTH
HEIGHT
LHB4
2
2
2
2
28, 54
32
73/16"
73/16"
46"
48"
3"
3"
LHB8
2
2
4
4
28, 54
32
73/16"
73/16"
933/16"
96"
3"
3"
MODEL
3"
3"
7316"
T5
7316"
T8
Note: Not intended for surface mounting. Provide a minimum of 3" clearance.
67
IC
INDUSTRIALS
Features
Ordering Information
IC
Model
IC Premium
No. of Lamps in
Cross Section
2 Two
3 Three
4 Four
Turret
Industrial
REFLECTOR TYPE
U Apertured 10% Uplight Reflector
ST Solid Top 0% Uplight Reflector1
VR Deep V Apertured Uplight
Lamp Type
32 4', T8: 32, 30,
48HO
96
96T8
96HO
96T8HO
Voltage
U 120V-277V
347 347V
28 or 25 Watt
4', T12: 60 Watt
8', T12: 75 or
60 Watt
8', T8: 59 Watt
8', T12: 110 or
95 Watt
8', T8: 86 Watt
Options
BC1 Branch Circuit Wiring Single
ICFC
ICNC
EL
GLR
GMF
RIF
NYC
NYCU
See Product
Availability table
below.
SIZE
4 4'
8 8'
Ballast
NOTE: See Technical Section for other ballast options.
E Electronic, Instant Start
3E 3-Lamp Electronic T8 (32W), Instant Start
4E 4-Lamp Electronic T8 (32W), Instant Start
EP Electronic, Programmed Start
LE Energy Saving Magnetic T12 (1-Lamp 48HO only)
Use programmed start ballast. Not recommended for use with instant start.
For more occupancy/daylight harvesting sensor accessories see page 98.
Product Availability
6"
139/16"
2-Lamp
Standard Reflector
ICWCB
ICRC
68
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
4'
(Standard
Reflector)
2
2
3
4
2
2
3
4
32
48HO
32
32
13916"
13916"
13916"
13916"
49"
49"
49"
49"
6"
6"
6"
6"
4' (Deep V
Reflector)
2
2
2
2
32
48HO
13916"
13916"
49"
49"
6"
6"
ICVWCB
8'
(Standard
Reflector)
2
2
3
3
4
4
2
6
3
4
32
96, 96T8, 96HO, 96T8HO
32
96, 96T8, 96HO, 96T8HO
59
13916"
13916"
13916"
13916"
13916"
98"
98"
98"
98"
98"
6"
6"
6"
6"
6"
ICBC
8' (Deep V
Reflector)
4
2
2
4
4
2
13916"
13916"
13916"
98"
49"
49"
6"
6"
6"
SIZE
6"
139/16"
2-Lamp
Deep V Reflector
KL
Premium Industrial
Features
Heavy gauge steel housing with longitudinal
ribs
INDUSTRIALS
Ordering Information
KL
Model
KL Premium
No. of Lamps
2 Two
3 Three
4 Four
Industrial
See Product
Availability
table below.
SIZE
4 4'
8 8'
16 16' (Two
housing)
96
96T8
96HO
96T8HO
1
REFLECTOR TYPE
U Apertured Uplight Reflector (Std.)
SLR Apertured Specular
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30,
48HO
54
28 or 25 Watt
4', T12: 60 Watt
4', T5HO: 54 or
51 Watt
8', T12: 75 or 60
Watt
8', T8: 59 Watt
8', T12: 110 or
95 Watt
8', T8: 86 Watt
Voltage
U 120V-277V
347 347V
Ballast
NOTE: See Technical Section for other ballast options.
E Electronic, Instant Start
3E 3-Lamp Electronic T8 (32W), Instant Start
4E 4-Lamp Electronic T8 (32W), Instant Start
EP Electronic, Programmed Start
24E (1) 2-Lamp and (1) 4-Lamp Electronic T8 (32W), Instant Start
3EP 3-Lamp Electronic T5HO or T8, Programmed Start
4EP 4-Lamp Electronic T5HO (N/A 347V) or T8, Programmed Start
Instant Start ballasts available for 32, 96, and 96T8.
Programmed Start ballasts available for all except 96 and 96T8.
Options
BC1 Branch Circuit Wiring Single
ACCESSORIES
(Order Separately)
S18 18" Stem, Canopy and
8" Aligner
Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories see page 98.
4316"
Product Availability
SIZE
4'
8'
16'
(Two
housings)
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
2
2
3
4
2
2
3
4
28, 32, 54
48HO
28, 32, 54
28, 32, 54
13"
13"
13"
13"
49716"
48"
49716"
49716"
6"*
6"*
6"
6"
2
2
3
3
4
4
2
6
3
4
28, 32, 54
96T8, 96HO, 96T8HO
28, 32, 54
59, 96HO, 96T8HO
96T8
13"
13"
13"
13"
13"
981316"
96"
981316"
96"
96"
6"*
6"*
6"
6"
6"
2
2
3
3
4
4
8
4
12
6
8
16
28, 32, 54
96T8, 96HO, 96T8HO
28, 32, 54
96T8, 96HO, 96T8HO
28, 32, 96T8
28, 32, 54
13"
13"
13"
13"
13"
13"
197"
192"
197"
192"
192"
197"
6"*
6"*
6"
6"
6"
6"
4316"
3"
3"
3"
6"
KL
3"
KL
4316"
4316"
2"
3"
3"
2"
2"
KL
2"
6"
13"
KL-VR
69
CSR
Industrial
INDUSTRIALS
Features
Ordering Information
CSR
Model
CSR Industrial
No. of Lamps
1 One
2 Two
3 Three (T8 or T5)
housings)
Voltage
U 120V-277V
347 347V
Lamp Type
28
32
48
48HO
54
96
96T8
96HO
96T8HO
REFLECTOR TYPE
ST Solid Top Reflector (Std.)
U Apertured Reflector for 5%
SIZE
4 4'
8 8'
16 16' (Two
Ballast
Options
BC1 Branch Circuit Wiring
Accessories
(Order Separately)
CSRWG Wireguard
CSHC Chain Hanger
(pair)
Hanger (pair)
OS1K Occupancy
Sensor Kit,
120/277/347V,
One Relay1
For more accessories see
pages 96-99.
1
Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories see page 98.
4"
4716"
" Diameter
3"
" Diameter
3"
70
LAMP TYPE
WIDTH
LENGTH
HEIGHT
4'
1
2
1
2
3
1
2
1
2
3
28, 32
28, 32
48, 48HO, 54
48, 48H0, 54
28, 32, 54
11"
11"
11"
11"
11"
48"
48"
48"
48"
48"
3"
3"
3"
4"
3"
8'
1
2
1
2
2
3
2
4
2
2
2
6
28, 32, 54
28, 32, 54
96, 96T8
96, 96T8
96HO, 96T8HO
28, 32
11"
11"
11"
11"
11"
11"
96"
96"
96"
96"
96"
96"
3"
3"
3"
3"
4"
3"
16'
(Two
housings)
2
2
2
8
4
4
28, 32, 54
96, 96T8
96HO, 96T8HO
11"
11"
11"
192"
192"
192"
3"
3"
4"
4"
" Diameter
" Diameter
3"
11"
HO
NO. OF
LAMPS IN
FIXTURE
RS
4316"
4"
NO. OF LAMPS IN
CROSS SECTION
SIZE
11"
11"
RS, Slimline
Product Availability
11"
T8
STRIPLIGHTS
Ordering Information
K
Model
K Heavy Duty
Channel
SIZE
4 4'
8 8'
16 16' (Two
No. of Lamps in
cross section
1 One
2 Two
See Product Availability
table below.
housings)
Lamp Type
28
32
48HO
54
96T8
96HO
96T8HO
Ballast
NOTE: See Technical Section
for other ballast options.
E Electronic T8, Instant
Start
4E 4-Lamp Electronic T8,
Instant Start
EP Electronic T5, T8,
or T12 (96HO only),
Programmed Start
4EP 4-Lamp Electronic
T5HO (N/A 347V) or T8,
Programmed Start
Voltage
U 120V-277V
347 347V
Options
BC1 Branch Circuit Wiring,
Accessories
(Order separately)
CSWG4
CSR4
CSRA4
S18
Product Availability
NO. of
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
4'
1
2
1
2
43/16"
43/16"
48"
48"
2"
2"
8'
1
2
1
2
43/16"
43/16"
96"
96"
2"
2"
16'
(Two housings)
1
2
2
4
43/16"
43/16"
192"
192"
2"
2"
SIZE
4316"
4316"
NO. OF LAMPS IN
CROSS SECTION
2"
2"
4"
4"
2"
71
CS
STRIPLIGHTS
Features
Ordering Information
CS
Model
CS StraightSided
Utility
Channel
SIZE
2
3
4
6
8
16
2'
3'
4'
6'
8'
16' (Two
housings)
No. of Lamps in
cross section
1 One
2 Two
3 Three
Lamp Type
14
17
21
24
25
28
32
See Product
Availability table
below.
39
48
54
96
96T8
Ballast
NOTE: See Technical Section
for other ballast options.
E Electronic T8, Instant
Start
3E 3-Lamp Electronic T8,
Instant Start
4E 4-Lamp Electronic T8,
Instant Start
24E (1) 2-Lamp and (1)
4-Lamp Electronic T8,
Instant Start
EP Electronic T5 or T8,
Programmed Start
3EP 3-Lamp Electronic T5 or
T8, Programmed Start
4EP 4-Lamp Electronic
T5HO (N/A 347V) or T8,
Programmed Start
Voltage
U 120V-277V
347 347V
Options
BC1 Branch Circuit Wiring,
Accessories
(Order separately)
CSWG3
CSWG4
CSR4
CSRA4
CSRU4
S18
SS18
CSHC
Product Availability
" Diameter Knockout
113/16"
211/16"
NO. OF LAMPS IN
CROSS SECTION
NO. OF LAMPS
IN FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
2'
1
2
3
1
2
3
14, 17, 24
14, 17, 24
17
47/16"
47/16"
47/16"
24"
24"
24"
113/16"
113/16"
113/16"
3'
1
2
3
1
2
3
21, 25, 39
21, 25, 39
25
47/16"
47/16"
47/16"
36"
36"
36"
113/16"
113/16"
113/16"
4'
1
2
3
1
2
3
47/16"
47/16"
47/16"
48"
48"
48"
113/16"
113/16"
113/16"
6'
1
2
3
2
4
6
21, 25, 39
21, 25, 39
21, 25, 39
47/16"
47/16"
47/16"
72"
72"
72"
113/16"
113/16"
113/16"
8'
1
1
2
2
3
2
1
4
2
6
28, 32, 54
96, 96T8
28, 32, 54
96, 96T8
28, 32
47/16"
47/16"
47/16"
47/16"
47/16"
96"
96"
96"
96"
96"
113/16"
113/16"
113/16"
113/16"
113/16"
16'
1
1
2
2
4
2
8
4
28, 32, 54
96, 96T8
28, 32, 54
96, 96T8
47/16"
47/16"
47/16"
47/16"
192"
192"
192"
192"
113/16"
113/16"
113/16"
113/16"
SIZE
47/16"
211/16"
47/16"
72
CH
STRIPLIGHTS
Ordering Information
CH
Model
CH Heavy
Duty
Narrow
Channel
SIZE
1.5
2
3
4
8
16
18"
2'
3'
4'
8'
16' (Two
housings)
No. of Lamps in
cross section
1 One
2 Two
See Product
Availability table
below.
Lamp Type
Ballast
14
15
17
21
24
25
28
30
32
Voltage
U 120V-277V
347 347V
Options
GLR Fast Blow Fuse
EL Emergency Battery Pack
PAF Paint After Fabrication
*Not available in all lamp/
ballast combinations. For more
options see pages 96-112.
Accessories
(Order separately)
CHWG4*
CHR4*
CHRA4*
S18
SS18
Product Availability
SIZE
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
1.5'
15
33/16"
18"
13/16"
2'
2'
1
2
1
2
14, 17, 24
14, 17, 24
33/16"
33/16"
24"
24"
13/16"
13/16"
3'
3'
1
2
1
2
33/16"
33/16"
36"
36"
13/16"
13/16"
4'
4'
1
2
1
2
33/16"
33/16"
48"
48"
13/16"
13/16"
8'
8'
1
2
2
4
28, 32, 54
23, 32, 53
33/16"
33/16"
96"
96"
13/16"
13/16"
1
2
4
8
28, 32, 54
28, 32, 54
33/16"
33/16"
192"
192"
13/16"
13/16"
33/16"
33/16"
113/16"
End Plate
19/16"
213/16"
113/16"
End Plate
19/16"
37/16"
CH-2LT8
CH-1LT12
73
CN/CNSS
T5 Channel
STRIPLIGHTS
Features
Ordering Information
Model
CN T5 Strip
CNSS T5 Staggered
SIZE
2 2'
3 3'
4 4'
5 5'
6 6'
8 8'
Strip
No. of Lamps in
cross section
1 One
2 Two
See Product
Availability table
below.
Lamp Type
14
21
24
28
35
39
54
Ballast
NOTE: See Technical Section
for other ballast options.
EP Electronic T5,
Programmed Start
4EP 4-Lamp Electronic
T5HO (N/A 347V),
Programmed Start
Voltage
U 120V-277V
347 347V
Options
GLR Fast Blow Fuse
GMF Slow Blow Fuse
PAF Paint After
Fabrication
EL Emergency
Battery Pack
(N/A in 2' and 3')
For more options see
pages 96-112.
Accessories
(Order separately)
CNR4*
CNRA4*
CNSAR4*
CNSARA4*
CNSSR4*
CNSSAR4*
CNSSARA4*
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP
TYPE
WIDTH
LENGTH
(CN)
LENGTH
(CNSS)
HEIGHT
2'
1
2
1
2
14, 24
14, 24
2"
2"
22"
22"
22"
26"
23/16"
23/16"
3'
1
2
1
2
21, 39
21, 39
2"
2"
345/16"
345/16"
345/16"
385/16"
23/16"
23/16"
4'
1
2
1
2
28, 54
28, 54
2"
2"
46"
46"
46"
50"
23/16"
23/16"
5'
1
2
1
2
35, 80
35, 80
2"
2"
5715/16"
5715/16"
5715/16"
6115/16"
23/16"
23/16"
6'
1
2
2
4
21, 39
21, 39
2"
2"
64"
64"
64"
72"
23/16"
23/16"
8'
1
2
2
4
28, 54
28, 54
2"
2"
92"*
92"*
87"
96"
23/16"
23/16"
SIZE
1"
1"
23/16"
2"
74
23/16"
2"
DE
STRIPLIGHTS
Ordering Information
DE
Model
DE Side
Lamp
Channel
SIZE
1.5 18"
2 2'
3 3'
4 4'
No. of Lamps in
cross section
1 One
2 Two
See Product
Availability table
below.
Lamp Type
15
17
25
30
32
Ballast
NOTE: See Technical Section
for other ballast options.
E Electronic T8, Instant
Start
EP Electronic T5 or T8,
Programmed Start
L Low Power Factor,
Non-energy Saving
(T12 lamps only)
Voltage
U 120V-277V
347 347V
Options
GLR Fast Blow Fuse
EL Emergency Battery Pack
(3' and 4' only)
Accessories
(Order separately)
S18 18" Stem, Canopy, and 8 Aligner
SS18 18", 45 Swivel Stem, and Canopy
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
Lamp
Type
Width
Length
Height
1.5'
1
2
1
2
15
15
2"
2"
18"
18"
1"
1"
2'
1
2
1
2
17
17
2"
2"
24"
24"
1"
1"
3'
1
2
1
2
25, 30
25, 30
2"
2"
36"
36"
1"
1"
4'
1
2
1
2
32
32
2"
2"
48"
48"
1"
1"
Size
2"
1"
2"
1"
" Dia. K.O.
31516"
75
SS
Staggered Strip
STRIPLIGHTS
Features
Ordering Information
SS
Model
SS Staggered
NO. of Lamps in
Cross Section
1 One
2 Two
Strip
(Individual
units)
See Product
Availability table
below.
Lamp Type
17 2', T8: 17 Watt
25 3', T8: 25 Watt
32 4', T8: 32, 30,
28 or 25 Watt
Reflector Type
Blank No Reflector
SYM Symmetric Reflector
ASYM Asymmetric Reflector
Voltage
U 120V-277V
347 347V
SIZE
1-Lamp
Length
2 24"
3 36"
4 48"
6 69"
8 93"
EL
GLR
LR
PAF
NYC
NYCU
Ballast
2-Lamp
Length
2 27"
3 39"
4 51"
6 75"
8 99"
Options
ADJ Adjustable 1-Lamp 4' or
Single Circuit (For more
branch circuit wiring
options see page 113)
Emergency Battery Pack
Fast Blow Fuse
Left/Right Switching
Paint After Fabrication
NYC Compliant
NYC Compliant, Union
Label
Reflector Accessories
(Order separately)
SSR
SSRA
SSRAK
SSRD
SSRDA
Product Availability
Wireway Cover
(cut to length)
4"
2"
4"
SS4-2
SS2-2
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
Lamp Type
Width
Length
Height
2'
1
2
1
2
14, 17, 24
14, 17, 24
4"
4"
24"
27"
2"
2"
3'
1
2
1
2
21, 25, 39
21, 25, 39
4"
4"
36"
39"
2"
2"
4'
1
2
1
2
28, 32, 54
28, 32, 54
4"
4"
48"
51"
2"
2"
6'
1
2
2
4
21, 25, 39
21, 25, 39
4"
4"
69"
75"
2"
2"
8'
1
2
2
4
28, 32, 54
28, 32, 54
4"
4"
93"
99"
2"
2"
Size
Adjustable Unit
76
Extreme enclosed and gasketed products fall into three groups based upon their suitability to different applications.
Suitability is based upon listings and ratings by various testing labs and trade organizations. Some options may upgrade a
fixtures suitability for more demanding environments.
For safety, careful evaluation is required to match the correct product with the intended application. Ambient temperature
extremes, NSF (food service, splash zone rating) and exposure to vandalism are some factors to consider.
Adverse: Used in protected or semi-protected outdoor locations. At a minimum these fixtures have UL1598 wet location
listings. They may have an IP54 rating (protected from sprays in all directions). Upgrades include stainless steel latches,
tough polycarbonate lens and vandal proof hardware.
Severe: Used when the application calls for greater dust and water protection. Typically, these products have a rating of
IP65 (protected against dust and low pressure jets of water), IP66 (protected from strong jets of water) or IP67 (temporary
immersion in 3' of water). Products may be covered by UL1958A for marine application. They are rugged products that can
endure exposure to most severe weather conditions.
Hazardous: Used in hazardous locations calling for a UL844 listing and an IP66 or greater rating. These units have been
evaluated for hazardous, caustic environments and ignition protection. Typically, they have a continuous metallic or high
strength resin housing supplied with hazardous rated ballasts and other high performance components.
Feature
ADVERSE
LUN
FNPV
LU
47A/47S
SEVERE
XFSW
NSF
Option
IP Rating
IP54
IP67
NEMA 4X
UL1598A
Marine
UL844
ABS
Hazardous
(Shipbuilding) Location
High
Ambient
x
x
x
x 47A
x
(Inside
Drip Proof)
x
(Inside
Drip Proof)
FNPS
Fiberglass Reinforced
Polyester Resin
IP65
FDPS
IP66
(2 ft.)
IP65
IP65
40C*
IP66
x
(Inside
Drip Proof)
50C*
IP65
XTS
FNPH
HAZARDOUS
Material
Fiberglass Reinforced
Polyester Resin
Fiberglass Reinforced
Polyester Resin
Extruded Aluminum
Formed Aluminum
or Steel
Fiberglass Reinforced
Polyester Resin
UL1598
Wet
Location
FDPH
FSPH
HZ
Extruded High
Impact Acrylic
Fiberglass Reinforced
Polyester Resin
Die Cast Aluminum
Die Formed
Stainless Steel
Formed Steel
40C*
50C*
x
x
* Maximum ambient temperature approved for product family (can change based on lamp type, markings and options).
77
LUN
Features
Fully gasketed
Ordering Information
LUN
Model
LUN Enclosed
and
Gasketed
Fiberglass
Industrial
SIZE
2 2'
4 4'
8 8'
No. of Lamps in
Cross Section
1 One
2 Two
3 Three
See Product
Availability table
below.
Lamp Type
17 2', T8: 17 Watt
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28
Ballast
or 25 Watt
4', T12HO: 60 Watt1
4', T8HO: 44 Watt
4', T5HO: 54 Watt
8', T12: 75 or 60
Watt
96T8 8', T8: 59 Watt
96HO 8', T12HO: 110 or
95 Watt1
96T8HO 8', T8HO: 86 Watt
1
High Output units should
not be surface mounted or
mounted in areas with warm
ambient temperatures.
48HO
48T8HO
54
96
Options
DR 50% DR Acrylic Lens
GLR Fast Blow Fuse
PP Clear Prismatic
Voltage
U 120V-277V
347 347V
Polycarbonate Lens
Tamper Resistant
Latches
TP Tamper Resistant
Latches
NYC NYC Compliant
NYCU NYC Compliant,
Union Label
Note: Contact your
local Columbia Lighting
representative for a list of
available battery packs.
Product Availability
79/16"
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
2'
1
2
1
2
17
17
79/16"
79/16"
2513/16"
2513/16"
61/8"
61/8"
4'
1
2
3*
1
2
3
28, 32, 54
28, 32, 48HO, 48T8HO, 54
32
79/16"
79/16"
79/16"
4913/16"
4913/16"
4913/16"
59/16"
59/16"
59/16"
8'
1
1
2
2
3*
2
1
4
2
6
28, 32, 54
96, 96T8, 96HO, 96T8HO
28, 32, 54
96, 96T8, 96HO, 96T8HO
32
79/16"
79/16"
79/16"
79/16"
79/16"
9713/16"
9713/16"
9713/16"
9713/16"
9713/16"
59/16"
59/16"
59/16"
59/16"
59/16"
SIZE
3"
59/16"
78
FNPV
NSF listed
EXTREME ENVIRONMENT
Ordering Information
FNPV
Model
FNPV Performer
Lens
No. of Lamps in
Cross Section
2 Two
Series,
Severe
Environment
2H
Blank
DR
CA
OA
PP
Voltage
U 120V-277V
347 347V
(HO only)
Entries
2H (2) "
Aluminum
Hubs
Options
GLR Fast Blow Fuse
MLID Marine Listed, Indoor
Drip Proof
SIZE
2 2'
4 4'
8 8'
Lamp Type
14
17
24
28
32
48T8HO
96T8
96T8HO
Ballast2
Tamper Resistant
Latches
TP Tamper Resistant
Latches
NYC NYC Compliant
NYCU NYC Compliant,
Union Label
Accessories3
(Order separately)
PTBS Top Bracket Surface Mount, 2 Per Kit,
304 Stainless
79/16"
Product Availability
SIZE
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
2'
14, 17, 24
6"
2515/16"
5"
4'
79/16"
4913/16"
55/16"
8'
2
2
2
4
96T8, 96T8HO
28, 32, 48T8HO
79/16"
79/16"
9713/16"
9713/16"
5"
5"
55/16"
79
LU
Features
Fully gasketed
Polypropylene latches
Ordering Information
LU
Model
LU Enclosed and
Gasketed
Aluminum
Industrial
SIZE
4 4'
8 8'
No. of Lamps in
Cross Section
1 One
2 Two
See Product
Availability table
below.
Lamp Type
32 4', T8: 32, 30,
28 or 25 Watt
Watt1
48T8HO 4', T8: 44 Watts1
96 8', T12: 75 or
60 Watt
96T8 8', T8: 59 Watt
96HO 8', T12: 110 or
95 Watt1
96T8HO 8', T8: 86 Watt1
1
High Output units should
not be surface mounted.
Ballast
Voltage
U 120V277V
347 347V
Options
DR 100% DR Acrylic Lens
EL Emergency Battery Pack
GLR
WL
NYC
NYCU
Product Availability
"
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
4'
1
2
1
2
8"
8"
50"
50"
5"
5"
8'
1
1
2
2
2
1
4
2
8"
8"
8"
8"
98"
98"
98"
98"
5"
5"
5"
5"
SIZE
80
7"
2"
3"
5"
27/16"
8"
47
EXTREME ENVIRONMENT
Ordering Information
Model
47A Aluminum
Housing
47S Steel
Housing
No. of Lamps in
Cross Section
1 One
2 Two
Ballast
Voltage
U 120V-277V
347 347V
Product Availability
Lens
DR12 Pat #12
High Impact
(Standard)
CPP Clear Prismatic
Polycarbonate
OP Frost Glaze
Acrylic Lens
UV UV Blocking
Acrylic Lens
Options
EL Factory Installed Damp
7"
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
4'
1
2
1
2
7"
7"
51"
51"
5"
5"
8'
1
1
2
2
2
1
4
2
7"
7"
7"
7"
99"
99"
99"
99"
5"
5"
5"
5"
SIZE
" Diameter
Knockout
5"
81
XFSW
Features
Ordering Information
XFSW
Model
XFSW Severe
Fiberglass
Low/High
Bay
SIZE
4 4'
No. of Lamps in
Cross Section
4 Four
6 Six
Lens Type
CA Clear Impact
Options
F5841 41K 85CRI 54W T5HO Lamps
Voltage
U 120V-277V
Resistant Acrylic
Installed
CP Clear UV
See Product
Availability table below.
Lamp Type
32 4', T8: 32, 30, 28,
or 25 Watt
54 4', T5HO: 54 or
51 Watt
Stabilized
Polycarbonate
Reflector
M4R 95% Reflective
Specular
Aluminum
(Narrow Beam)
GW Gloss White
(Wide Beam)
Installed
F3C15W
XFSW4-454
4EP (1) 4-Lamp Electronic T5HO,
F3C8WQ
Programmed Start
XFSW4-654
24EP (1) 2-Lamp and (1) 4-Lamp Electronic
T5HO, Programmed Start
XFSW4-432
4EHL (1) 4-Lamp Electronic T8, High Light
F3C15WQ
Accessories
(Order Separately)
LHVQM5 Aircraft Cable, 5' (Pair)
LHVQM10 Aircraft Cable, 10' (Pair)
XFSWSB Surface Mount Bracket,
XFSW4-632
3EHL (2) 3-Lamp Electronic T8, High Light
4'
7"
50"
" Entry
11/16"
6"
82
14"
GLR
GMF
Product Availability
SIZE
7"
OSWL
NO. OF LAMPS IN
CROSS SECTION
LAMP TYPE
WIDTH
LENGTH
HEIGHT
4
6
32, 54
32, 54
14"
14"
50"
50"
6"
6"
FNPS
EXTREME ENVIRONMENT
Ordering Information
FNPS
Model
FNPS Performer
No. of Lamps in
Cross Section
2 Two
3 Three (4' only)
4 Four (4' only)
Series,
Severe
Environment
SIZE
4 4'
8 8'
Lens
Blank
DR
CA
OA
PP
Lamp Type
28
32
48T8HO
96T8
96HO
96T8HO
Voltage
U 120V-277V
347 347V (HO only)
Ballast2
Entries
2H (2) "
Aluminum
Hubs
2HS (2) 1/2"
Stainless
Steel Hubs
2H3S (2) 3/4"
Stainless
Steel Hubs
2HMS (2) 20mm
Stainless
Steel
Hubs3
Options
GLR Fast Blow Fuse
MLID Marine Listed,
Tamper Resistant
Latches
TP Tamper Resistant
Latches
Accessories3
(Order separately)
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
4'
2
3
4
2
3
4
79/16"
79/16"
79/16"
4913/16"
4913/16"
4913/16"
55/16"
55/16"
55/16"
8'
79/16"
9713/16"
5"
SIZE
55/16"
FNPS
83
FDPS
Features
Gasket (silicone)
Ordering Information
FDPS
Model
FDPS Die Cast
No. of Lamps in
Cross Section
2 Two
3 Three
Performer
Series,
Severe
Environment
Lens
CP Clear Polycarbonate
Smooth
PP Clear Prismatic
Lamp Type
14 2', T5: 14 Watt
17 2', T8: 17 Watt
24
28
32
48T8HO
GLR
ML
NC
VPS
Polycarbonate
See Product
Availability table
below.
SIZE
2 2'
4 4'
Options
Voltage
U 120V-277V
347 347V
(2-Lamp only)
2', T5HO: 24 Watt
(2-Lamp only)
4', T5: 28 Watt
4', T8: 32, 30, 28
or 25 Watt
4', T8HO: 44 Watt
Ballast1
Accessories3
(Order separately)
Ballasts may not be available in all combinations of lamp/voltage/starting temp/THD shown above.
Fusing not available.
3
Mounting hardware not included with accessories.
4
Recommend use of PTBS & PTBA accessories with stainless steel hubs.
2
5"
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
2'
2
3
2
3
14, 17, 24
14
5"
5"
27"
27"
49/16"
49/16"
4'
2
3
2
3
5"
5"
50"
50"
49/16"
49/16"
SIZE
49/16"
84
XTS
EXTREME ENVIRONMENT
Ordering Information
XTS
Model
XTS Enclosed and
No. of Lamps in
Cross Section
2 Two
Gasketed Acrylic
Tube, Severe
Environment
Reflector
M4R 95% Reflective
Specular
Aluminum
(Narrow Beam)
GW Gloss White
(Wide Beam)
See Product
Availability table
below.
SIZE
4 4'
8 8'
Lamp Type
32 4', T8: 32, 30, 28,
or 25 Watt
54 4', T5HO: 54 or
51 Watt
SIZE
Voltage
U 120V-277V
Lamps INstalled
FO841 41K 82CRI 32W T8
Lamps Installed
Ballast*
NOTE: See Technical Section for other ballast options.
E (1) 2-Lamp Electronic T8, Instant Start
4E (1) 4-Lamp Electronic T8, Instant Start
EHL (1) 2-Lamp Electronic T8,
High Light Output, Instant Start
4EHL (1) 4-Lamp Electronic T8,
High Light Output, Instant Start
EP (1) 2-Lamp Electronic T5, Programmed Start
4EP (1) 4-Lamp Electronic T5HO, Programmed Start
EPHL (1) 2-Lamp Electronic T8,
High Light Output, Programmed Start
4EPHL (1) 4-Lamp Electronic T8,
High Light Output, Programmed Start
*For NEMA premium ballast, add prefix N. e.g., NEPHL.
Options
F3C6WT 6' Mini-Quick
disconnect cord
set. Threaded male
receptacle, strain
relief installed in end
cap. Straight threaded
female plug one end
of cord, other end has
stripped leads ready
for feed installation
F3C12WT 12' Mini-Quick
disconnect cord
set. Threaded male
receptacle, strain
relief installed in end
cap. Straight threaded
female plug one end
of cord, other end has
stripped leads ready
for feed installation
GLR Fast Blow Fuse
GMF Slow Blow Fuse
50" / 97"
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS
LAMP
TYPE
DIAMETER
LENGTH
4'
32, 54
6"
50"
8'
32, 54
6"
97"
6"
Hanger
Bracket
7"
85
FNPH
Features
For use in wet, outdoor, hazardous, hosedown,
applications
requirements
stainless steel
Ordering Information
FNPH
Model
FNPH Performer
Lens
No. of Lamps in
Cross Section
2 Two
3 Three
4 Four
Series,
Hazardous
Location
Blank
DR
CA
OA
PP
See Product
Availability table
below.
SIZE
Lamp Type
4 4'
Voltage
U 120V-277V
347 347V
Ballast1
25 Watt
Entries
2H (2) "
Aluminum
Hubs
2HS (2) 1/2"
Stainless
Steel Hubs
2H3S (2) 3/4"
Stainless
Steel Hubs
2HMS (2) 20mm
Stainless
Steel Hubs3
Options
BHD65U Hazardous and
Damp Rated
Emergency Battery
Pack
GLR Fast Blow Fuse3
SSLTP Stainless Steel
Tamper Resistant
Latches
TP Tamper Resistant
Latches
Accessories2
(Order separately)
PTBS Top Bracket Surface Mount, 2 Per Kit,
304 Stainless4
Ballasts may not be available in all combinations of lamp/voltage/starting temp/THD shown above.
20mm entries not CSA or ABS certified.
3
Fusing not available with CSA certification.
4
Recommend use of PTBS & PTBA accessories with stainless steel hubs.
2
Product Availability
SIZE
4'
86
79/16"
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
AMBIENT
CLASS 1
DIV 2
CLASS 1
ZONE 2
LENGTH
2
2
3
3
4
2
2
3
3
4
32
28
28
32
28
40C
40C
40C
35C
40C
T5
T5
T4A
T5
T4A
T5
T5
T4
T5
T4
4913/16"
4913/16"
4913/16"
4913/16"
4913/16"
55/16"
FDPH
EXTREME ENVIRONMENT
Gasket - silicone
Finish - electrostatically applied baked powder
polyester paint
housing
clear
5mm driver)
Ordering Information
FDPH
Model
FDPH Die Cast
No. of Lamps in
Cross Section
2 Two
3 Three (4' only)
Performer
Series,
Hazardous
Location
Lens
CP Clear Polycarbonate
Smooth
PP Clear Prismatic
Polycarbonate
See Product
Availability table
below.
SIZE
2 2'
4 4'
Options
GLR Fast Blow Fuse
ML UL 1598 Marine Outdoor
NC National Sanitation
Foundation
Lamp Type
14
17
28
32
Voltage
U 120V-277V
347 347V
Ballast2
Accessories
(Order separately)
PTBS Top Bracket Surface Mount,
2 Per Kit, 304 Stainless
Product Availability
5"
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
CLASS 1
DIV 2
CLASS 1
ZONE 2
CLASS 2
ZONE 2
LENGTH
2'
2
3
2
3
14, 17
14
T6
T4A
T6
T4
T6
T6
27"
27"
4'
2
3
2
3
28, 32
28
T5
T5
T5
T5
50"
50"
SIZE
49/16"
FDPH
87
FSPH
Features
Ordering Information
FSPH
Model
FSPH Stainless
SIZE
4 4'
Steel
Performer
Series,
Hazardous
Location
32
Lens
Blank Tempered Glass
DR Acrylic High Impact,
No. of Lamps in
Cross Section
1 One
2 Two
3 Three
Voltage
U 120V-277V
347 347V
100% DR
CP Clear Polycarbonate
Options
BHD65U Hazardous and Damp
Rated Emergency
Battery Pack
NC National Sanitation
Foundation Certified
Lamp Type
Ballast 1
Accessories
(Order separately)
FSPHWA Top Bracket Wall/Angle Kit,
Ballasts may not be available in all combinations of lamp/voltage/starting temp/THD shown above.
Contact your local Columbia Lighting Representative for more details.
Product Availability
SIZE
4"
4'
8"
88
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP TYPE
WIDTH
LENGTH
HEIGHT
1
2
3
1
2
3
32
32
32
8"
8"
8"
51"
51"
51"
4"
4"
4"
HZ
20 gauge housing
EXTREME ENVIRONMENT
Ordering Information
HZ
Model
HZ Hazardous
No. of Lamps in
Cross Section
2 Two
3 Three
4 Four
Location
Troffer
FS
See Product
Availability table
below.
SIZE
14 1' 4' (2- and 3-Lamp only)
22 2' 2' (2-Lamp only)
24 2' 4'
Lamp Type
32 4', T8: 32, 30,
28 or 25 Watt
Doors
FS Flush Steel
Fully Hinged
Door Frame
Leg Spacing
T8: 32 Watt
Ceiling Type
G Lay-in Grid
F Flange with Wing Hangers
Ballast
NOTE: See Technical Section
for other ballast options.
E Electronic T8, Instant
Start
3E 3-Lamp Electronic T8,
Instant Start
4E 4-Lamp Electronic T8,
Instant Start
Lens
TG73 Tempered Glass,
Pattern 73
TG Tempered Glass
DR12 Pattern 12 Acrylic
Options
NYC NYC
Compliant
NYCU NYC
Compliant,
Union Label
Voltage
U 120V-277V
347 347V
Lens, Impact
Resistant, 0.140"
PP12 Pattern 12
Polycarbonate
Prismatic Lens
Product Availability
SIZE
NO. OF LAMPS
LAMP TYPE
HEIGHT
1' 4'
2
3
32
32
5"
5"
2' 2'
32U6
5"
2' 4'
2
3
4
32
32
32
5"
5"
5"
5"
24"
HZ24-4
5"
12"
HZ14-2
89
CLEANROOM Guide
Cleanroom Lighting
Cleanroom Class
1
10
100
1000
10000
100000
90
0.1
35
350
N/A
N/A
N/A
N/A
5.0
N/A
N/A
N/A
7
70
700
CRS
Cleanroom, Class 1
Features
EXTREME ENVIRONMENT
Ordering Information
CRS
Model
CRS Cleanroom,
No. of Lamps in
Cross Section
Ceiling Type
G Lay-in Inverted
Ballast2
Door
FA Flush Aluminum
FCS Flush One-Piece
Voltage
U 120V-277V
347 347V
Options
1T 1" T-Bar
2T 2" T-Bar (1' 4'
and 2' 4' only)
with Emergency
Battery Pack)
NYC NYC Compliant
NYCU NYC Compliant,
Union Label
Grid
Product Availability
SIZE
NO. OF LAMPS
LAMP TYPE
HEIGHT
1' 4'
2
3
28, 32, 54
28, 32
5"
5"
2' 2'
2
3
4
5"
5"
5"
2' 4'
2
3
4
6
28, 32, 54
28, 32, 54
28, 32, 54
28, 32, 54
5"
5"
5"
5"
61/8"
Surface
5"
12"
CRS14-2
24"
2' 2' and 2' 4' End Section
5"
63/8"
12"
CRS14-2
24"
2' 2' and 2' 4' End Section
91
CRC
EXTREME ENVIRONMENT
Features
Mitered corners
Ordering Information
CRC
Model
CRC Cleanroom,
Class 1000
No. of Lamps
2 Two
3 Three
4 Four
SIZE
14 1' 4'
22 2' 2'
24 2' 4'
FA
Ceiling Type
G Lay-in Inverted
1" or 1" Grid
32
32U6
40TT
54
Door
FA Flush Aluminum
Ballast
F Flange (Wing
Hangers)
Lamp Type
14
17
24
28
31U1
Shielding
A12 Pattern 12 Acrylic Lens
A12125 Pattern 12 Acrylic Lens,
0.125" Nominal
Product Availability
5"
24"
CRC14-2
5"
24"
CRC22-2
5"
24"
CRC24-3
5"
24"
CRC24-2
92
Voltage
5"
24"
CRC24-4
SIZE
NO. OF LAMPS
LAMP TYPE
HEIGHT
1' 4'
2
3
5"
5"
2' 2'
2
3
4
5"
5"
5"
2' 4'
2
3
4
5"
5"
5"
Morph
O u t d oo r
MB
MC
Ordering Information
Model
MBA Box Sided
NO. of lamps
2 Two
4 Four
Area Light
Mounting
Blank None
A8 Bolt On Arm
AA2 Adjustable 2"
Wall Mount
MCA Chamfered
Area Light
MCW Chamfered
Wall Mount
TG
Slipfitter Arm
Lens
TG Tempered
Distribution
MBA and MCA
5 Standard Optics
Glass
Voltage
U 120V-277V
HU 347V-480V
(Type V)
2R Forward Throw Optics
(Right hand, Type II*)
2L Forward Throw Optics
(Left hand, Type II*)
SIZE
2 2'
4 4'
Lamp type
24 2', T5HO: 24 Watt
54 4', T5HO: 54, 51,
Finish
DB Dark Bronze
BL Black
GR Gray
or 49 Watt
Ballast
2-Lamp
EP Electronic T5HO,
Options
F5841 41K 85CRI T5HO Lamps
Installed
Programmed Start
4-Lamp
4EP 4-Lamp Electronic
T5HO, Programmed
Start, Switchable
(54W only)
Street Side
A8
HS
2R
Locking Photocell
GLR
GMF
HS
OS
*Beam Direction
AA2
Installed
2L
House Side
Product Availability
9"
EPA Values
MOdel
NO. OF LAMPS In
Cross Section
LAMP
TYPE
Length
MBA2/MCA2
MBA4/MCA4
2, 4
2, 4
24
54
26.5"*
50.5"*
MBW2/MCW2
MBW4/MCW4
2, 4
2, 4
24
54
26.5"*
50.5"*
MOdel
Single
Twin
@
90
Twin
@
180
Triple
@
90
Triple
@
180
Quad
@
90
MBA2
MBA2 w/OS
1.6
1.7
3.2
3.5
3.2
3.5
4.7
5.2
4.7
5.2
6.3
7.0
MB Standard Optics
MCA2
MCA2 w/OS
1.5
1.6
2.9
3.2
2.9
3.2
4.4
4.8
4.4
4.8
5.8
6.4
9"
MBA4
MBA4 w/OS
2.7
2.9
5.4
5.7
5.4
5.7
8.1
8.6
8.1
8.6
10.8
11.4
MCA4
MCA4 w/OS
2.5
2.6
5.0
5.3
5.0
5.3
7.5
7.9
7.5
7.9
10.0
10.6
AA2
0.5
1.0
1.0
1.5
1.5
2.0
A8
0.3
0.6
0.6
0.9
0.9
1.2
9"
6"
MC Standard Optics
6"
6"
MC Forward Throw Optics
(Right hand shown)
93
Morph ACCESSORIES
Catalog No.
O u t d oo r
Item
Description
WMB-XX1
TA-4-XX1
TA-5-XX1
TA-6-XX1
PTA190-XX1
PTA2180-XX1
PTA290-XX1
PTA390-XX1
PTA3120-XX1
PTA490-XX1
PTASSA8-XX1
TP
1
ft.
Nominal
Shaft
Dim.
16
4.9
19.5
14
10.5
20
6.1
13.5
9.5
25
7.6
8.5
30
9.1
18
70
MPH
Bolt
Circle
Pole
Bolt Wt.
Proj. (lbs)
120
MPH
Wall
Thick.
(Sugg.)
Bolt
Circle
Bolt (Sq.)
Base Plate
(Sq.)
Anchor
Bolt Size
7.5
0.119
11"
8-11"
5.6-7.8"
10 "
30 3"
4"
128
6.5
4.5
1.8
0.119
11"
8-11"
5.6-7.8"
10 "
30 3"
4"
160
1.5
NR
0.119
11"
8-11"
5.6-7.8"
10 "
30 3"
4"
238
12
4.5
NR
0.179
11"
1013.5"
7.1-9.5"
12 1"
1 36 4"
4"
398
All poles are painted Dark Bronze and are drilled on all four sides with our #2 and #6 pattern.
They include: Poles Shaft, Anchor Bolts, Pole Cap, Anchor Bolt Template, Anchor Base Covers
See additional Spaulding pole offerings on pages 610-625.
See Wind Speeds table on page 611.
Anchor Bolt Detail Base Program
Anchor Rod
Hex Nut
Anchor Bolt
Location in
Relation
to Shaft
Rotation
Plain Washer
Base Plate
Grout Finish Grade
Bolt Projection
Plain Washer
Hex Nut
Grout after pole is set
and plumbed
Foundation Level
94
Handhole
Straight Square
and Tapered Poles
Engineering of
footing by others
Bolt Circle
Bolt Square
SLA
O u t d oo r
Ordering Information
SLA
Model
SLA Outdoor
No. of lamps In
Cross Section
1 One
Sign and
Faade
Luminaire
options
DR High Impact Lens
ANO Anodized Diffuse
Exterior (Gray)
Lamp type
SIZE 1
4 4'
6 6'
8 8'
32
48
48HO
72
72HO
96
96T8
96HO
96T8HO
Lamp Type
No. of lamps
OPerated
1 One
2 Two
Voltage
U 120V-277V (T8
See housing
Lamp Type.
and T5 only)
347 347V
Ballast
E Electronic T8, T12 or Slimline
OPtions
GRAY Gray Ballast
Box (Std.
White)
NYC NYC
Compliant
NYCU NYC
Compliant,
Union Label
SLA
Model
SLA Outdoor
No. of lamps In
Cross Section
1 One
SIZE 1
4 4'
Sign and
Faade
Luminaire
Lamp Type
28 4', T5: 28 Watt
(Indoor only)
54 4', T5HO: 54
options
Blank Gloss White
ANO Anodized
or 51 Watt
(Indoor only)
Diffuse
Exterior
(Gray)
EP
Ballast
EP Electronic,
Programmed
Start
Voltage
U 120V-277V (T8
and T5 only)
347 347U
Sizes shown are based on nominal housing lengths. Where units will be mounted in rows, please provide row information. E.g. One 16' row consisting of (4) SLA4-154-EPU.
Product Availability
NO. OF LAMPS in
Cross section
No. of Lamps
in Fixture
LAMP TYPE
Width
Length*
HEIGHT
4'
1
1
1
1
28, 32, 54
48HO
53/16"
53/16"
51"
49"
33/16"
33/16"
6'
72HO
53/16"
73"
33/16"
8'
96T8, 96HO
53/16"
97"
33/16"
SIZE
Conduit supplied by
others. Seal conduit
thread with sealing
compound.
Gasket cemented in socket
housing cover.
Neoprene sleeves
provide watertight
seal between lamp
and socket housing.
UL Reflector end block.
Optional plastic shield. Recommended
for severe cold weather condition.
53/16"
33/16"
2"
95
Accessories
Mounting Accessories
Surface Mount Hangers
Technical
Cat. No.
ITB-4
CS-2
CS-4
CS-5
All purpose spacer with special T-Bar clip and stud for
All surface mounted fixtures
mounting to an inverted T-Bar ceiling. Maintains 1" spacing.
CSZT
KZT
Zip tee hanger 1" spacer. Designed for 15/16" wide T-Bars.
Zip tee hanger 1" spacer. Designed for 15/16" wide T-Bars.
CSTH
KTH
LHVTH
LHV
LHSH6
LHSH4
PEBU
PEBUHSMS
PEBA
PEBAHSMS
PTBS
PTBS3
PTBA
PTBA3
FSPHB
FSPHWA
96
Description
Hanger for mounting close to ceiling on T-Bar grid system
FNPV, FNPS
FNPV, FNPS, FDPS, FNPH, FDPH
FNPV, FNPS, FDPS, FNPH, FDPH
FNPV, FNPS, FDPS, FNPH, FDPH
FNPV, FNPS, FDPS, FNPH, FDPH
FSPH
FSPH
Accessories
Mounting Accessories
Cat. No.
SSHK
LU
CSHC
Chain hanging assembly includes two 24" lengths of chain and two
hanger hooks.
Chain hanging assembly includes two 24" lengths of chain and two
hanger hooks.
Chain hanger assembly, #3 size double loop chain, 12'.
Cable hangers, #2 size cable with loop-end, 5', 10', and 20'
lengths, adjustable
CS and CSR
Y-Fit Hook Cable Hangers, #2 size cable, 5', 10', and 20' lengths,
adjustable
LHV
KHC
ICHC
GLH5
GLH10
GLH20
LHVQM5
LHVQM10
LHVQM20
CM24
CM48
Technical
Description
Chain hanging (chain not included)
LUNHK
Cat. No.
Description
HUBK
Stem hanging kit consists of two die cast hubs, two O rings and LUN, FNPV, LU, FNPS, FNPH, FDPH
locknuts. Hubs are threaded for " pipe. Housings must be drilled
to install hubs.
S18D
SB3
MWW 3-lamp
EWW 3-lamp
AWW 3-lamp
WCW 3-lamp
S18
SS18
C18
SO18
97
Accessories
Technical
Chain Hangers
LHVWG-6 shown
Cat. No.
Description
KLRAC
KLVRAC
Full range aligners (set of two) for aligning reflector flanges and
closing gaps between two reflectors. White
KL
KL-V
KLEC
KL and KL-V
KC2
LHV 4-lamp
LHV 6-lamp
LHR 4-lamp
LHR 6-lamp
LHR Narrow
LHEM
LHEW
IC
KL
CSR
CSR
CSR
CS
CS
K, CS
CH
CH
CH
KL (not available with KL-V)
LHVWG-4
LHVWG-6
LHRWG4K
LHRWG4K
LHRNWG
LHEMWG
LHEWWG
ICWG4
KLWG4
CSRWG4-4PK
CSRWG2-4PK
CSRWG3-4PK
CSWG2-24PK
CSWG3-12PK
CSWG4
CHWG2-12PK
CHWG3-12PK
CHWG4-12PK
KLEGG
KLFSA12
LHVOS1
LHVOS2
LHVOS480
LHVODS1
LHVODS2
LHVODS480
*Factory installed sensor options available with LHV fixture, see page 60.
98
OS1K
OS2K
OS480K
ODS1K
Accessories
Reflector Accessories
Technical
3"
3"
6"
41116"
Symmetric
CHR2 Symmetric reflector for 2' fixtures.
CHR3 Symmetric reflector for 3' fixtures.
CHR4 Symmetric reflector for 4' fixtures
Asymmetric
CHRA2 Asymmetric reflector for 2' fixtures.
CHRA4 Asymmetric reflector for 4' fixtures.
CHR and CHRA reflectors are secured to channel with sheet metal screws provided.
CHR and CHRA reflectors are pre-finished with baked enamel, 86% minimum reflectance.
Polyester powder coat paint after fabrication (PAF) available as option.
3"
3"
11"
7"
Symmetric - CSR4
Symmetric reflector for 4' fixtures (order two for 8' units).
Center saddles are required for 8' channels.
For CS channel order center saddle CSSAD.
For K channel order center saddle KSAD.
Asymmetric - CSRA4
Asymmetric reflector for 4' fixtures (order two for 8' units).
Center saddles are required for 8' channels.
For CS channel order center saddle CSSAD.
For K channel order center saddle KSAD.
CSR and CSRA reflectors are attached with captive quarter turn fasteners included.
CSR and CSRA reflectors are pre-finished with baked enamel, 86% minimum reflectance.
Polyester powder coat paint after fabrication (PAF) available as option.
67/16"
63/4"
39/16"
SSRA
Asymmetric
(1 piece)
5"
518/32"
47/16"
47/16"
SSRAK
Asymmetric Kicker
(1 piece only)
SSRD
Symmetric Deep
(2 pieces)
SSRDA
Asymmetric Deep
(1 piece)
Ordering Guide: Show reflector as option on strip catalog number. (Example: SS4-132SYM-EU-SSR)
Notes
1. Symmetric reflectors consist of two pieces.
2. Asymmetric reflectors consist of one piece.
3. Adjustable housings require 4' reflectors for field adjustment.
4. Use of reflector(s) on staggered strip requires modification to strip housing. Bulk reflectors should not be ordered except as replacements.
5. Reflectors attach with sheet metal screws, provided.
Reflectors are pre-finished with baked white enamel, 86% minimum reflectance.
Polyester powder coat paint after fabrication (PAF) available as option.
99
Recessed Options
Air Handling
Technical
Designation
Description
Air Function
-S
Static
-A
Air Supply/Return
Air flows into room from plenum or back into plenum from room. We provide slots in housing.
For optional vanes, see below.
-H
Heat Extract
Slots are provided in end cap or back of housing (instead of through black reveal). Units
without a black reveal feature slots in door for air passage to lamp compartment. For optional
dampers, see below.
-C
Combined
Supply
Return
Vanes (V) Also referred to as air pattern blades or directional air vanes.
Vanes work with supply/return air (-A or -C). Vanes open outward, from 0 to 90 degrees, like a door swinging open. To control air flow, adjust
opening as desired or close completely. When used on a -C fixture, vanes operate independently of dampers.
Dampers (D) Also referred to as heat removal dampers or control dampers.
Dampers work with extract air (-H, -C). Dampers slide open, like a window. To control air flow, adjust opening as desired or close entirely. When
used on a -C fixture, dampers are controlled independently of vanes.
Designation
Description
Designation
Description
-AV
-HD
-CV
-CD
-CVD
Black Reveal
Slide Direction
Slider Panel (inside)
Knockouts (3)
Slide Panel Screws (2)
Vane (open)
100
Recessed Options
Ceiling Trims
Ceiling Type
Recommended Trim
1" T-Bar
G (Grid)
Cross Section
Availability
Technical
SG (Slot Grid)
Hard Ceiling
F (Flange)
Metal Pan
M (Modular)
101
Recessed Options
Flange Trims
Max.
Technical
Min.
Recessed Opening
Overall Trim
Dimensional Example
Parabolics
Rough-In Dimensions
Specify option INT (intermediate) or EOR (end of row).
Vertical Wing
Hanger Adjust
Overall Trim
Dimensions
Single
or Row
Single
Unit
Row Length
Series
Size
Min.
Max.
Width
Length
Width
Length
Nom.
Length
P4, HC
1' 4'
2' 2'
2' 4'
1' 4'
2' 2'
2' 4'
9" 4'
1"
1"
1"
1"
1"
1"
2"
4"
3"
3"
3"
3"
3"
4"
121316"
241316"
241316"
121316"
241316"
241316"
10"
481316"
241316"
481316"
481316"
241316"
481316"
48"
12"
24"
24"
12"
24"
24"
9"
48"
24"
48"
48"
24"
48"
48"
48"
24"
48"
48"
24"
48"
48"
45
VHC, PVHC
Lensed Troffers
Multiply
by
Plus
Example
# in row
# in row
# in row
# in row
# in row
# in row
# in row
"
"
"
"
"
"
"
Rough-In Dimensions
Specify option INT (intermediate) or EOR (end of row).
Vertical Wing
Hanger Adjust
Series
4PS, 4VS
5PA
ST8, WT
102
Size
Min.
1' 4'
"
2' 2'
2' 4'
1' 4'
2' 2'
2' 4'
1' 4'
2' 2'
2' 4'
1' 4'
2' 2'
2' 4'
1' 4'
2' 2'
2' 4'
1' 4'
2' 2'
2' 4'
1"
1"
"
1"
1"
1"
1"
1"
13/4"
13/4"
13/4"
13/4"
13/4"
13/4"
35/8"
35/8"
35/8"
Overall Trim
Dimensions
Single
or Row
Single
Unit
Row Length
Width
Length
Width
Length
Nom.
Length
3"
12"
48"
12"
48"
48"
2"
2
3"
2"
2"
33/16"
33/16"
33/16"
41/2"
41/2"
41/2"
41/2"
41/2"
41/2"
41/8"
41/8"
41/8"
24"
24"
12"
24"
24"
12"
24"
24"
1215/16"
2415/16"
2415/16"
1211/16"
2411/16"
2411/16"
12"
24"
24"
24"
48"
48"
24"
48"
49"
24"
49"
4911/16"
243/4"
4911/16"
487/8"
247/8"
487/8"
483/4"
243/4"
483/4"
24"
24"
12"
24"
24"
12"
24"
24"
111/4"
231/4"
231/4"
12"
24"
24"
12"
24"
24"
24"
48"
48"
24"
48"
48"
24"
48"
481/4 "
241/4"
481/4"
481/4"
241/4"
481/4"
48"
24"
48"
24"
48"
48"
24"
48"
48"
24"
48"
48"
24"
48"
48"
24"
48"
48"
24"
48"
Max.
Multiply
by
Plus
Example
# in row
"
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
# in row
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Recessed Accessories
Flange Kit and Plaster Frame Information
Flange Kits
Technical
Flange kits are extruded aluminum frames that act as individual fixture T-Bar frames to support the weight of any G (grid) trim recessed fixture
in drywall or plaster ceilings. Kits snap together without the use of tools (18 gauge galvanized corner clips provided) and are hung by tie wire
(by others) from the ceiling support structure.
From the room side flange kits mimic the appearance of T-Bars in a baked white enamel finish. Consult chart for ceiling cut out dimension.
For continuous row applications order flange kits plus one FKCR, continuous row flange connector kit, for each joint between fixtures.
(One less than the number of fixtures in the row.)
Flange Kit
Catalog No.
Size
FK14
1' 4'
FK22
2' 2'
FK24
2' 4'
FK44
4' 4'
FK81
8" 1'
FK82
8" 2'
FK84
8" 4'
Ceiling Opening
Width
Length
12"
48"
24"
24"
24"
48"
48"
48"
8"
12"
8"
24"
8"
48"
FKCR
Side Rail
End Rail
Plaster Frames
Plaster frames are galvanized steel rails used to trim ceiling openings primarily in wet plaster applications. They are installed during
ceiling construction and help maintain the correct opening dimensions for installation of flange ST8 trimmed recessed fixtures. See fixture
specification sheet for dimensions required for framing to support the weight of the fixture.
Use plaster inside dimensions for framing opening in dry ceilings.
Framing (by others) required to support the weight of the fixture.
Catalog No.
PL14
PL14R
PL22
PL24
PL24R
PL44
Description
Individual
For Rows
Individual
Individual
For Rows
Individual
Nominal Size
1' 4'
1' 4'
2' 2'
2' 4'
2' 4'
4' 4'
Inside Dimension
12" 48"
24" 24"
24" 48"
48" 48"
1"
"
Plaster Frames:
For mounting any Columbia Lighting flanged troffer
in a plaster ceiling
Provides a clean, finished appearance
103
Standards Compliance
Technical
Columbia Lighting can provide a fire rated label (FR option) which states that our recessed
light fixtures are manufactured in accordance with UL1598 and, therefore, can be installed
in a fire rated ceiling system. There are no additional requirements of a recessed fixture in
order for it to be used in a fire rated design.
I need a fire rated troffer.
A true fire rated troffer does not exist because UL does not list troffers as fire rated.
Instead, they list ceiling systems which may include UL listed troffers as part of that system.
But my inspector says I need one.
Your inspector has authority and jurisdiction over your project. However, a better understanding of the fire rated ceiling system process can help
in your discussions. Order the FR option where required by local authorities.
I remember fire rated troffers from jobs past.
UL listed three ceiling designs using a special fire rated troffer many years ago. Columbia Lighting (and a few others) offered this troffer, which
consisted of a recessed unit with a sheet of fire resistant material attached to the back of it. Since all three ceilings have been obsolete for
decades (some exceptions in Canada), Columbia Lighting no longer manufactures this troffer. Instead, we manufacture in accordance with UL
1598, which allows our recessed fixtures to be installed in a fire rated ceiling system.
Fire Rated Enclosures
An FR label does not indicate whether or not tenting of the fixtures is required; all installation must be in accordance with the UL Fire Rated
Ceiling design.
Non-integral Clip
Ballast Disconnect
All Columbia fixtures are in compliance with NEC and CEC requirements for ballast disconnects by including integral ballast disconnects in
required fixtures.
The following fixtures are excluded from the ballast disconnect requirement:
Hazardous location fixturesHZ, FNPH, FDPH, FSPH, CRS (with D2 option)
Fixtures with emergency battery pack options
104
Ballast Options
Ballast Types
Ballast Types
Start Method
Definition
Designation
E
Characteristics
Standard (.87-1.0 BF)
E104
EnergyMax 1.04 BF
EHL
ELW
ETT
EP
Standard, 0.88 BF
EPTT
EP_
EPSP8
EPSP5
ESD
ESD104
ESD80
ED_
Start Method
Definition
Designation
L
Characteristics
For residential fixtures using 2', 3', or 4'
Bi-pin T12 lamp types.
105
Technical
Columbia Lighting supplies ballasts from a variety of reputable vendors whose products conform to Columbia Lightings
standard specifications (pg. 107). See Ballast Specified Vendor Options to order a particular manufacturers product or ballast
series. All ballast information is based on manufacturer's published literature and is subject to change without notice.
Ballast Options
Technical
Fixtures with 3, 4, 6, and 8 lamps will be supplied with two ballasts standard. Optional ballast quantities are available.
See also Master-Satellite option for ballast quantity options on tandem-wired pairs. In tandem-length fixtures with more than one ballast, lamps
are wired side by side unless left and right (LR option) is specified.
Number of Lamps in Fixture
1 or 2
Standard Designation
Must specify
Consult factory
Specified Vendors*
Specify ballast type, optional ballast quantity and vendor option. Eg. 3ED120LUTFDB
Vendor
Vendor
Specified Designation
LUT
ULT
GE
SYL
ADV
LUTEC10
Eco10 Dimming
LUTHIL
Hi-Lume Dimming
LUTES
LUTESSW
LUTEHD
EcoSystem H
ULTHE
Ultim8
ULTHP
High Performance
GEMAXH
Ultramax High BF
GEMAXL
Ultramax Low BF
GEMAXN
Ultramax
SYLQHE
High Efficiency
SYLPSX
Extreme
SYLPHO
Helios Dimming
SYLDIM
Powersense Dimming
ADVCEN
Centium
ADVIOP
Optanium
ADVMK10
Mark X Dimming
ADVMK7
*Others available, call out ballast catalog number in fixture description. Dimming ballasts use ED plus voltage and vendor designation.
106
Ballast Options
Technical
Measure of how effectively ballast converts power source into usable watts. Ideal power factor would measure 1.0.
Crest Factor
Measure specifying the ratio of peak current to R.M.S. current in the waveform used to drive programmed start lamps. High crest factors shorten
lamp life.
Total Harmonic Distortion
Measure of magnitude of input current harmonics compared with amplitude of fundamental frequency current.
Ballast Factor
Lamp manufacturers publish lumen data based upon a reference ballast built to meet ANSI standards. Ballast factor is a measure of how well a
ballast performs in comparison to the reference ballast as a percentage of rated lumen output.
Ballast Type
Electronic
Programmed
Start
T5
Electronic
Programmed
Start
T8
Catalog
Designation
EP
EP
EP
EP
EP
EP
EP
EP
3EP
4EP
EP80
EP95
EP115
ESD80
ESD95
ESD104
ESD115
EP
EP
EP104
3EP
4EP
Lamp Type
F14/T5
F14/T5
F24/T5HO
F24/T5HO
F28/T5
F28/T5
F54/T5HO
F54/T5HO
F54/T5HO
F54/T5HO
F54/T5HO
F28/T5
F28/T5
F54/T5HO
F28/T5
F32/T8
F28/T5
F32/T8
F32/T8
F32/T8
F32/T8
F32/T8
No. of Input
Lamps Watts*
1
19
2
34
1
28
2
53
1
34
2
66
1
63
2
121
3
182
4
240
2
96
2
60
2
69
2
96/52
2
60/28
2
65/32.5
1, 2
71/34
1
31
2
62
2
65
3
92
4
119
Ballast Type
Electronic
Instant Start
T8
Electronic
T12
Electronic
TT
Catalog
Designation
E
E
3E
4E
E
E
E
E
E104
E104
E105
E
E
EP
EP
ETT
ETT
3ETT
EPTT
EPTT
3EPTT
No. of Input
Lamp Type
Lamps Watts*
F32/T8
1
30
F32/T8
2
56
F32/T8
3
85
F32/T8
4
112
F96/T8
1
70
F96/T8
2
108
F96/HO/T8
1
100
F96/HO/T8
2
185
F32/T8
2
67/66
F32/T8 (28 watt)
2
60/59
F32/T8 (25 watt)
2
51/51
F96/T12/ES
1
64
F96/T12/ES
2
105
F96/T12/HO
1
119
F96/T12/HO
2
208
F40/TT
1
39
F40/TT
2
68
F40/TT
3
99
F40TT
1
38
F40TT
2
76
F40TT
3
110
*Where published input watts differ between 120/277V the higher (120V) wattage is given. For 2 level step dim ballasts (ESD types) both high and
low output wattages are given.
107
Electrical Options
Emergency Battery Packs Installed
Technical
Luminaires with factory installed battery packs will bear the UL Emergency equipment label. Dry location labeling standard. Standard inverter
options below are not suitable for cold temperature starting, damp or wet location labeling. Optional inverters available for these applications.
Consult factory or specify vendors catalog number.
EL
EL61
EL71
EL72
350-450 lumens for one 2'-4' lamp (T8, T12, U-Bent, TT)
500-600 lumens for one 2'-4' lamp (T8, T12, U-Bent, TT)
600-700 lumens for one 2'-8' lamp (T8, T12, U-Bent, TT)
600-700 total lumens for two 2'-8' lamps (T8, T12, U-Bent)
EL141
EL142
EL5*
EL5H*
1100-1400 lumens for one 2'-8' lamp (T8, T12, U-Bent, TT)
1100-1400 total lumens for two 2'-4' lamps
390-700 lumens for one 2'-4' T5/T5HO
725-1250 lumens for one 2'-4' T5/T5HO
*These inverters not available in some 2' fixtures due to space constraints. Remote mounting using accessory enclosure (by others) recommended.
Fusing
Fusing is available on all fixtures to prevent over current from being transmitted upstream through the fixture as may be possible due to a dead
short fault in a ballast. Specify GLR (fast blow) or GMF (slow blow) fusing options. Fuses are not UL listed to break under load and therefore are
not a substitute for the in-fixture ballast disconnects supplied standard where required by the National Electric Code.
Cable
No. of Wires
C Cable
Cable Diameter
3 3
4 4
5 5
8 "
2 "
Wire gauge
8 18 gauge
4 14 gauge
2 12 gauge
Miscellaneous Fixtures and Electrical Options (add As Suffix on end of Catalog string)
Fixture/Option
Cat. No.
PSW
PSWD
4PSW
Description
Pull switch, one circuit, 120V only
Pull switch, wired to the downlight circuit on a two circuit unit, 120V only
Four-way pull switch for two circuit, two lamp unit, 120V only
NL
Medium base lampholder for 15W, 25W, 40W, or 60W T10 lamp. Lamp not
included. 120V only
AWN, SM units
PL7
PL9
PL13
GCO
C6P15_ 6' Cord and Straight Blade, NEMA 5-15P, 15A (Add Voltage: 1 = 120)
C6TL15_ 6' Cord and Twist-Lock Plug, NEMA L5-15P (120V) NEMA L7-15P (277V), 15A
(Add Voltage: 1 = 120, 2 =277)
C6TL20_ 6' Cord and Twist-Lock Plug, NEMA L5-20P (120V) NEMA L7-20P (277V), 20A
(Add Voltage: 1 = 120, 2 =277)
F3C_
3-Conductor feed cord, 18ga stranded wire
(Add length needed: 5 = 5', 10 = 10', or 15 = 15')
F4C_
4-Conductor feed cord, 18ga stranded wire
(Add length needed: 5 = 5', 10 = 10', or 15 = 15')
GLR
Fast blow fuse, fuse amps based on fixture ordered
108
All fixtures
Wiring Options
Master Unit
Satellite Unit
Ballast
Master
Satellite
E, EP
(2) 2-Lamp
(1) 2-Lamp
24E, 24EP
None
Layout Options
8'
F
Satellite Unit
Fixture Position
12'
10'
8'
K
4'
Position
6'
7'
8'
9'
8'
10'
7'
7'
8'
9'
9'
Master Unit
Line Feed
Adapter Plate
K.O.
109
Wiring Options
Branch Circuits
Technical
Plug-On Branch Circuit Wiring System features complete branch circuit wiring. You supply the feeder; Plug-On does the rest. The system will
handle all popular voltage/phase combinations 2 or 3 wire, 120V, 277V, or 240V, and 3-phase, 4 wire 120/208V or 277/480V-20 amp rating. It
is UL listed and combines the following features:
Available on all continuous row surface mounted fixtures for up to 20 amp circuit runs. Supplied as single or multiple circuit with these
fixtures: Surface (PT, AW), Strips (CS, CN, K, LB, KT, SS), Industrials (KL, CSR).
Available for easy wiring connections for single circuit (BC1), multiple circuits (BC2A, BC2B) or alternating AB or ABC patterns (BC2X, BC3X)
for up to 4 circuits in a row.
May be used with any conventional hanging method chain, Zip-Tee, slide clamp, stem, or stud.
Add "G" to option to add a ground wire in harness
Complete, ready for connection as shipped no separate parts to misplace. Connectors snap-lock for positive mechanical connection and are
color coded for instant identification.
Carton and channel marked for ballast circuit identity aids installation, distribution, and maintenance.
Free factory consulting on coordination of order is recommended to assure proper application.
Catalog Number
-Suffix
Description
-BC1
-BC2A
-BC2B
-BC2AB
Black and red wires. Ballast on each plus white. Add L/R
option for left/right (in-line) switching
-BC2X
-BC3X
-BC3A
-BC3B
-BC3C
-BC4A
-BC4B
-BC4C
-BC4D
4 Circuit (5 Wire)
110
Technical
Many fixtures can be ordered with lamps pre-installed. Some fixture designs are not available pre-lamped because there is no installation or
shipping advantage. Lamp options listed below provide the factorys choice of reputable vendors. Insert lamp option after ballast voltage
designation in fixture catalog number. NFO and reduced wattage designations provide lamps meeting applicable NEMA Premium and CEE listing
criteria.
Color Rendering Index (CRI) refers to how accurately the lamps phosphor blend reproduces colors compared with a natural source (sunlight).
Color temperature refers to how warm (3000K) or cool (4100K) the light appears. Candlelight represents an extreme warm (reddish)
temperature while sunlight represents an extreme cool (blue-white) temperature.
Please specify vendors catalog number if a specific vendor, series or lamp feature is required. Reduced wattage lamps may not be suitable for
dimming or cold temperature applications. Consult vendors specification.
Lamp Profile
(f = Fluorescent)
FO
FO30
FO28
FO25
NFO
F5
FTT
T8 (full wattage)
4' T8 reduced wattage (30W)1
4' T8 reduced wattage (28W)1 (PLUS)
4' T8 reduced wattage (25W)1
4' T8, NEMA Premium Full wattage (32W)
T5 or T5HO
Twin Tube
Color Rendering
Index
Color
Temperature
7 Minimum 75
8 Minimum 82 (T8) or
85 (T5) (Required for
NEMA Premium/CEE)
30 3000K
35 3500K
41 4100K
Lamp Shape
Blank Straight or Twin Tube
U6 U-Lamp 6" Leg Spacing
U1 U-Lamp 1" Leg Spacing
Packaging Options
Products are shipped in individual cartons standard. In fixtures ordered in pallet quantities or greater specify choice of job packaging to ease
fixture handling and reduce job site waste disposal. Option available on lensed and parabolic troffers.
JP
Job pack. Fixtures less cartons, with protective outer packaging and stretch-wrapped to standard 4-way pallet.
PN
Job pack narrow, less cartons, with protected outer packaging and stretch-wrapped to 4-way pallet no greater than 24" inches wide.
111
Technical
Troubleshooting
Flickering Lamps
Cycling of Ballast
1. Line voltage varies.
Check line voltage to make sure constant power is supplied.
2. Replace lamps to verify ballast problem.
3. Insulation covering fixtures.
Check to make sure that fixtures are not covered. Excess heat will
cause thermal protector to cycle.
4. Fixtures are mounted on ceiling directly.
Verify that fixtures are designed to be mounted directly to ceiling.
If not, an air space must be provided between ceiling and fixtures.
2. Lamp compatibility.
Cross check lamps against ballast designation listed on ballast
case. Some energy saving lamps and ballasts are not compatible.
3. Incorrect or loose wiring.
Disconnect power and check all wiring connections.
4. Check fuses if supplied.
Disconnect power before removing. Check with ohmmeter or test
equipment. Reinstall and energize.
5. Line voltage low.
Voltage range for 120 volts is 112 minimum and 125 maximum.
Voltage range for 277 volts is 255 minimum and 289 maximum.
6. Low ambient temperature.
Fluorescent lamps are hard to start at temperatures below 50F.
7. Are lamps properly engaged in the lampholders?
Check to make sure that pins are properly engaged.
Noise
Slow Starting
3. Incorrect lamp.
Make sure lamps are compatible with ballast.
112
RKT
F I X T U R E R E N OVAT I O N
Ordering Information
RKT
Model
RKT Retrofit Kit
Lens Troffer
No. of Lamps in
Cross Section
2 Two
3 Three
SIZE
22 2' 2'
24 2' 4'
Reflector Type
GW Gloss White, 91% Reflective
M4R Enhanced Specular Aluminum,
95% Reflective
Lamp Type
17 2', T8: 17 Watt
32 4', T8: 32, 30, 28 or 25 Watt
Voltage
U 120V-277V
Options
GTS Hi-Lo Control, Single Circuit Toggle
Switch (used for Step Dimming
Ballast)
Ballast
NOTE: See Technical Section for other ballast options.
ELW Electronic T8, Instant Start, 0.77 Ballast Factor
E Electronic T8, Instant Start, 0.88 Ballast Factor
E104 Electronic T8, Instant Start, 1.04 Ballast Factor
EHL Electronic T8, Instant Start, 1.18 Ballast Factor
ESD Electronic T8, Step Dimming, Programmed Start, 0.88
Ballast Factor
EP Electronic T8, Programmed Start, 0.88 Ballast Factor
3ELW 3-Lamp Electronic T8, Instant Start, 0.77 Ballast Factor
3E 3-Lamp Electronic T8, Instant Start, 0.88 Ballast
3EHL 3-Lamp Electronic T8, Instant Start, 1.04 Ballast Factor
3EP 3-Lamp Electronic T8, Programmed Start, 0.88 Ballast
Factor
Blank No Ballast supplied (Please specify socket type under
options)
Product Availability
SIZE
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP
TYPE
2' 2'
2, 3
2, 3
17
2' 4'
2, 3
2, 3
32
2.26"
9.00"
18.08"
2-Lamp Cross Section
113
RKS/RKSR
Features
Ordering Information
Model
RKS Retrofit Kit
Strip Type
Fixtures
RKSR Retrofit Kit
Industrial
Reflector
Type
SIZE
4 4'
8 8'
No. of Lamps in
Cross Section
1 One
2 Two
See Product
Availability table
below.
Reflector Type
(RKSR ONLY)
GW Gloss White, 91%
U
Voltage
U 120V- 277V
Reflective
Lamp Type
32 4', T8: 32, 30,
Options
(Required when no ballast is supplied.)
IS8 Instant Start T8 Sockets
PS8 Programmed Start T8 Sockets
PS5 Programmed Start T5 Sockets
Ballast
NOTE: See Technical Section for other ballast options.
ELW 1 or 2-Lamp, Electronic T8, Instant Start, 0.77 Ballast Factor
E 1 or 2-Lamp, Electronic T8, Instant Start, 0.88 Ballast Factor
EHL 1 or 2-Lamp, Electronic T8, Instant Start, 1.18 Ballast Factor
ESD 1 or 2-Lamp, Electronic T8, Step Dimming, Programmed Start,
0.88 Ballast Factor
EP 1 or 2-Lamp, Electronic T8, Programmed Start, 0.88 Ballast
Factor or Electronic T5HO, 1.0 Ballast Factor
4ELW 4-Lamp, Electronic T8, Instant Start, 0.77 Ballast Factor
4E 4-Lamp, Electronic T8, Instant Start, 0.88 Ballast Factor
4EHL 4-Lamp, Electronic T8, Instant Start, 1.18 Ballast Factor
4EP 4-Lamp, Electronic T8, Programmed Start, 0.88 Ballast Factor
or Electronic T5HO, 1.0 Ballast Factor
Blank No Ballast Supplied (Please specify socket type under
options)
28 or 25 Watt
54 4', T5HO: 54 or
51 Watt
Product Availability
NO. OF LAMPS IN
CROSS SECTION
NO. OF
LAMPS IN
FIXTURE
LAMP
TYPE
4'
1
2
1
2
32, 54
32, 54
8'
1
2
2
4
32, 54
32, 54
SIZE
RKS
2-Lamp
RKSR
2-Lamp
114
RKS
1-Lamp
RKSR
1-Lamp
ZPT - Zero Plenum Troffer High Efficiency Architectural Luminaire, Mt. Sinai Hospital, New York, NY