Вы находитесь на странице: 1из 16

Dual Fiber and Coaxial Video Transmission

Document No.: ES0195A00015


Revision: 02
Revision Date: 2010-01-04

Datasheet Module R07

ES0195A00015

Module R07

Datasheet Module R07

Copyright 2009 by ERA a.s. Pardubice

All rights reserved. This document and the information it contains are property of ERA a.s. and
confidential. They shall not be reproduced nor disclosed to any person except to those having a need
to know them, without prior written consent of ERA a.s.

L500: ES0195A00015-02
ERA a.s.
Prmyslov 387
530 03 Pardubice
Czech Republic
Tel: + 420 467 004 253
Fax: +420 466 670 461
www.erabeyondradar.com

Module R07

Datasheet

Table of Contents
1

PURPOSE..............................................................................................5

BLOCK DIAGRAM.................................................................................5

BRIEF TECHNICAL DESCRIPTION......................................................6

LIST OF ESSENTIAL PARAMETERS...................................................7

SUBJECT ILLUSTRATION WITH PARTICULAR PARTS


LABELING .............................................................................................9

LIST OF CONNECTION POINTS ........................................................11

LIST OF INDICATORS ........................................................................11

INDICATION AND LOCALIZATION OF ERROR CONDITIONS .........12

LIST OF SETUP AND CONTROL ELEMENTS ...................................12

10

LIST OF DIAGNOSTIC OUTPUTS ......................................................12

11

REPLACEMENT PROCEDURE ..........................................................13

11.1
11.2

DISASSEMBLY .............................................................................................................13
ASSEMBLY ..................................................................................................................13

Module R07

Datasheet

Purpose
The SSR RX HD R07 module represents a high sensitive receiver of pulse
signals equipped with a SSR signal digital pulse selector enabling to process
SSR replies. The receiver has excellent dynamic range and it is suitable for
any applications within MSS. The receiver is equipped with dual output of the
fiber and coaxial video.

Block Diagram

Figure 2-1 R07 Module Block diagram

Datasheet

Module R07

Brief Technical Description


The R07 module consists of following main parts:

Overvoltage protection (OVP SSR ES0130A00230).


EMC filter (EMCF ES0100A00553).
Band pass filter (BPF SSR ES0130A00227).
SSR receiver (RXI2 ES0140A00465).

Over-voltage coaxial protection is designated to protection electrical


equipment against atmospheric surge and secondary effect lightning.
Band-pass filter is used for non-SSR signals elimination.
Receiver RXI2 processes SSR signal passes through surge suppressor and
band-pass filter. The input signal is directly amplified, filtered and
demodulated by logarithmic detector. Demodulated signal is amplified in a
differential driver and led to ten bits A/D converter. Digitalized signal is
entering into FPGA circuit. The Receiver RXI2 is controlled by the FPGA
circuit of Xilinx Spartan 3 series. A 32-bit embedded processor Microblaze is
recorded into FPGA.
The FPGA circuits performs following functions: processing of digitalized
signal, digital pulse selection functions, diagnostics of the receiver, data
communications, signaling operating states and conditions.
The processed signal is converted to fibre and coaxial video signal.
Three LED indicators serve as a signalization of operating states and
conditions.
The receiver firmware together with the communication software enables a
change of the receiver configuration parameters:
Threshold, i.e. the signal level on the receiver input, which is not,
processed more in the digital pulse selector.
Output configurations register (CfgOut). The register content determines
the status (off/on) of particular outputs of the optical and coaxial video,
changes the way of operating states indication, controls the status
(off/on) of the detector of A,C-mode and S-mode responses, controls
entering of diagnostic pulses and interrogation marks to the output video.

Module R07

Datasheet

List of Essential Parameters


Electrical parameters
Input impedance

50 , SWR 1.5 max.

Sensitivity S0,9

-90 dBm min. (typical -92 dBm)

Dynamic range

90 dB min.

Bandwidth (3 dB)

16 MHz
90 dB (DC 860 MHz) min.

Spurious signals suppression

85 dB (860 MHz 960 MHz) min.


55 dB (960 MHz 1030 MHz) min.

Power supply

+20 V +28 V (nominal +24 V) DC

Power consumption

7 W max.

Input signal
SSR replies Mode A,C
Carrier frequency

1090 MHz 3 MHz

Pulse duration

0.45 s 0.1 s

Pulse rise time

0.1 s max.

Pulse decay time

0.2 s max.

Replies Mode S
Carrier frequency

1090 MHz 1 MHz

Pulse duration

0.5 s 0.05 s or 1.0 s 0.05 s

Pulse rise time

0.1 s max.

Pulse decay time

0.2 s max.

Output signal
Dual fiber video
Wave length

1310 nm

Output power

-8 dBm min. (-5 dBm typical)

Optical fiber

9/125 m single mode

Dual coaxial video


Amplitude

TTL

Polarization

positive

Impedance

75

Datasheet

Module R07

Mechanical parameters
WxHxD
(without holders and connectors)

58 mm x 291 mm x 291 mm

Weight

4.2 kg

Operational conditions

Climate specification

Environmental effects

EMC

Tested according to

Temperature range
-40 C +60 C

SN ETS 300 019-2-4, class 4.1 E

Humidity
rh < 0 %, 100 % >

SN ETS 300 019-2-4, class 4.1 E

IP67

MIL-STD-810F/METHOD 512.4

Salt fog

MIL-STD-810F/METHOD 509.4

Fungus (Microbiotics)

MIL-STD-810F/METHOD 508.5

Compliant

EMI - SN EN 61000-6-3
EMS - SN EN 61000-6-2

Sinusoidal vibration
(a 1 g, f 200 Hz)

SN ETS 300 019-2-4, class 4.1 E


SN EN 60068-2-6 Fc, class 4M5

Shock (a 25 g)
Duration 6 ms

SN ETS 300 019-2-4, class 4.1 E


SN EN 60068-2-29, class 4M5,
method Eb

Mechanical specification

Storage conditions
Climate specification

-50 C +70 C

SN EN 60068-2-14 Nb

Reliability
MTBF

100 000 hours

Module R07

Subject Illustration with Particular Parts Labeling

(291)

(58)

(291)

Datasheet

Figure 5-1 R07 Module Drawing

Datasheet

Figure 5-2 R07 Module 3D view

10

Module R07

Module R07

Datasheet

List of Connection Points


Label
1

Input

Power supply;
signal mains failure (power supply failure).

Input

Synchronizing signal of the Module Txx interrogation marker.

Output

Input

Output

Input/Output

COM/PGM

Description

Dual fiber video.


Signal from receiving antenna.
Dual coaxial video.
For service purposes.

List of Indicators
Label

Type

RUN

Green LED

Receiver processor operation indication.


Blinking processor running, other states not indicated.

Yellow LED

Receiver internal temperature diagnostics.


Blinking temperature in normal range (-43.2 C +80 C).
Continual light temperature outside normal range.

Yellow LED

Receiver power supply diagnostics.


Blinking all supply voltages in allowed range.
Continual light at least one voltage outside allowed range.

DIAG 1

DIAG 2

Description

Extended indication:
If at least a single bit of 4 (A/C-mode) or 5 (S-mode) of the output
configuration register set to 1, the response detector of A/C mode or S-mode
shall be active, and the way of operating states indication shall be changed.
The data frames reception is evaluated on the video line in regular intervals
of ten seconds. If a single or several A/C or S-mode responses detected, the
firmware shall change from the basic indication to the display indicating the
type of detected response. The display beginning and end is separated from
the basic indication by means of distinct extinguishing of all LEDs. The RUN
LED shall display the type of received responses by means of double blink in
the midst of diagnostic indication. Types of responses are coded by the
lengths of the RUN LED on states (see table below).
If no response detected in the interval of ten seconds, the LED display mode
shall not change, and only basic indication states shall be valid.

11

Datasheet

Type of
detected
response

A/C mode

S mode

A/C&S mode

LED
indication

Module R07

Indication mode

Interval [s]

3.2

0.2

0.4

0.8

3.2

RUN

off

on

off

on

off

DIAG 1

off

off

off

off

off

DIAG 2

off

off

off

off

off

Interval [s]

3.2

0.8

0.4

0.2

3.2

RUN

off

on

off

on

off

DIAG 1

off

off

off

off

off

DIAG 2

off

off

off

off

off

Interval [s]

3.2

0.8

0.4

0.8

3.2

RUN

off

on

off

on

off

DIAG 1

off

off

off

off

off

DIAG 2

off

off

off

off

off

On state: LED lights in given time interval; off state: LED extinguishes in
given time interval.

Indication and Localization of Error Conditions


The device is provided with the indication of its own faulty states (see
paragraph 7) and mediates a transfer of the power supply state via diagnostic
pulse in the optical and coaxial video. The power supply state is indicated by
the mains fail signal status (mains failure, power supply failure) as follows:

Mains fail signal

Diagnostic pulse duration/(period)

+20 V +28 V

30 s/(40 ms approx.)

0 V (high impedance)

43 s/(40 ms approx.)

List of Setup and Control Elements


No equipment setup and control elements are accessible to the customer.

10

List of Diagnostic Outputs


No diagnostic outputs are accessible to the customer.

12

Module R07

11

Datasheet

Replacement Procedure

Holders

Locking screw

Figure 11-1 R07 Module Replacement

11.1

Disassembly

11.2

Remove connector shrink protections.


Disconnect supply cable, antenna cable.
Disconnect optical or metallic cable or both.
Disconnect grounding cable.
Slacken locking screw.
Eject entire module upwards.
Remove the module from the cabinet.

Assembly

Shift the module into the cabinet, suspend it in pertinent position.


Tighten the locking screw.
Connect the grounding cable.
Connect optical or metallic cable or both.
Connect antenna cable and supply cable.
Mount connector shrink protections.

13