Вы находитесь на странице: 1из 2

Federal Register / Vol. 70, No.

65 / Wednesday, April 6, 2005 / Notices 17509

[FR Doc. 05–6803 Filed 4–5–05; 8:45 am] float on top of the product at a certain to adjust the measurements on their
BILLING CODE 4910–60–M level. The tank also had legs that strapping tables to ensure accuracy.
supported the roof whenever the Issued in Washington, DC, on March 18,
product was drained and the volume of 2005.
DEPARTMENT OF TRANSPORTATION liquid in the tank decreased to the level Theodore L. Willke,
at which the roof no longer floated.
Pipeline and Hazardous Materials Deputy Associate Administrator for Pipeline
Additionally, the tank had two Safety.
Safety Administration Supervisory Control and Data
[FR Doc. 05–6729 Filed 4–5–05; 8:45 am]
Acquisition System (SCADA) alarms to
Pipeline Safety: Strapping Table alert controllers when the volume was BILLING CODE 4910–60–P
Calibration for Pipeline Breakout Tank nearing the level at which the roof
Operators would no longer float. The alarm set DEPARTMENT OF TRANSPORTATION
AGENCY: Office of Pipeline Safety (OPS), points were based on the landed height
Pipeline and Hazardous Materials Safety of the floating roof assumed in the Pipeline and Hazardous Materials
Administration (PHMSA), DOT. operator’s strapping table. Safety Administration
NTSB determined that based on the
ACTION: Notice; issuance of advisory [Docket No. RSPA–04–19914; Notice 1]
height measurement of the floating roof
bulletin.
documented on the construction
inspection report, and based on Pipeline Safety: Petition for Waiver;
SUMMARY: This advisory notice alerts
measurements investigators made after Enstar Natural Gas Company
pipeline operators of all hazardous
liquid pipeline facility systems about the accident, the strapping table was AGENCY: Pipeline and Hazardous
the need to validate the accuracy of incorrect. Specifically, the distance from Materials Safety Administration
breakout tank strapping tables. Under the bottom of the pontoon to the datum (PHMSA), U.S. Department of
certain circumstances, strapping table plate was found to be higher than Transportation (DOT).
errors can potentially lead to dangerous indicated on the pre-accident strapping ACTION: Notice; Petition for Waiver.
conditions. table. The surface of the charged diesel
FOR FURTHER INFORMATION CONTACT: Joy was within approximately two inches of SUMMARY: Enstar Natural Gas Company
Kadnar by phone at (202) 366–0568, by the pontoons at the time of the (Enstar) has petitioned the Office of
fax at (202) 366–4566, or by e-mail, explosion. This, according to NTSB, is Pipeline Safety (OPS) for a waiver of the
joy.kadnar@dot.gov. General the most likely time for a static pipeline safety regulation that prohibits
information about the Pipeline and discharge to occur. Based on this tracer wire from being wrapped around
Hazardous Materials Safety finding, as well as other contributing the pipe.
Administration’s Office of Pipeline factors, the NTSB determined that an DATES: Persons interested in submitting
Safety (OPS) programs may be obtained incorrect measurement on the strapping written comments on the waiver request
by accessing the home page at http:// table contributed to the cause(s) of the described in this Notice must do so by
ops.dot.gov. accident. May 6, 2005. Late filed comments will
SUPPLEMENTARY INFORMATION: II. Advisory Bulletin ADB–05–02 be considered so far as practicable.
To: Owners and Operators of All ADDRESSES: You may submit written
I. Background comments by mailing or delivering an
Pipeline Facilities Who Rely on
A breakout tank exploded and Strapping Tables to Determine Volume original and two copies to the Dockets
subsequently ignited in Glenpool, Based on Measured Height For Product Facility, U.S. Department of
Oklahoma on April 7, 2003. The Level. Transportation, Room PL–401, 400
accident involved an 80,000-barrel Subject: Validation of Strapping Seventh Street, SW., Washington, DC
breakout tank that exploded and burned Tables to Reduce the Likelihood of 20590–0001. The Dockets Facility is
as it was being filled with diesel. The Errors That May Lead to Dangerous open from 10 a.m. to 5 p.m., Monday
resulting fire burned for over 20 hours Conditions in Breakout Tanks. through Friday, except on Federal
and damaged two other nearby breakout Purpose: To advise owners and holidays when the facility is closed.
tanks. While there were no injuries or operators of all hazardous liquid Alternatively, you may submit written
fatalities, the cost of the accident pipeline facilities about the need to comments to the docket electronically at
exceeded two million dollars, residents validate strapping tables. the following Web address: http://
adjacent to the accident site were Advisory: Strapping Tables are dms.dot.gov.
evacuated, and area schools were closed commonly used to determine the All written comments should identify
for two days. commodity volume based on product the docket and notice numbers stated in
The National Transportation Safety level within breakout tanks. If the the heading of this notice. Anyone who
Board (NTSB) conducted an strapping table is incorrect, operators wants confirmation of mailed comments
investigation into the accident and may expose themselves and the must include a self-addressed stamped
subsequently published a Pipeline community to unnecessary risks. postcard. To file written comments
Accident Report titled ‘‘Storage Tank OPS seeks to advise operators that electronically, after logging on to
Explosion and Fire in Glenpool, they should review and, if necessary, http://dms.dot.gov, click on ‘‘Comment/
Oklahoma.’’ In its findings adopted on revise their breakout tank operating Submissions.’’ You can also read
October 13, 2004, the NTSB issued a procedures to minimize risk. The comments and other material in the
recommendation to OPS to issue an strapping tables should be validated to docket. General information about the
advisory bulletin to liquid pipeline reduce the potential for errors that may Federal pipeline safety program is
operators to validate the accuracy of lead to dangerous conditions, such as available at http://ops.dot.gov.
their tank strapping tables. static discharge inside a tank after a Anyone is able to search the
The breakout tank that exploded floating roof has been either electronic form of all comments
contained an internal floating roof intentionally or unintentionally landed. received into any of our dockets by the
system equipped with pontoons that Pipeline operators, therefore, may need name of the individual submitting the

VerDate jul<14>2003 18:17 Apr 05, 2005 Jkt 205001 PO 00000 Frm 00108 Fmt 4703 Sfmt 4703 E:\FR\FM\06APN1.SGM 06APN1
17510 Federal Register / Vol. 70, No. 65 / Wednesday, April 6, 2005 / Notices

comment (or signing the comment if party damages and 17,000 to 18,000 line Avenue NW., Washington, DC 20224, or
submitted on behalf of an association, locates each year. Enstar contends that through the Internet, at
business, labor union, etc.). You may this regulation is designed to redress a Allan.M.Hopkins@irs.gov.
review DOT’s complete Privacy Act problem that does not exist within the SUPPLEMENTARY INFORMATION:
Statement in the Federal Register Enstar pipeline service area. Title: IRS e-file Electronic funds
published on April 11, 2000 (volume 65, For the reasons cited above, Enstar is Withdrawal Authorization for Form
number 70; pages 19477–78) or you may requesting a waiver from the pipeline 7004.
visit http://dms.dot.gov. requirements at § 192.321(e). Enstar’s OMB Number: 1545–1927.
FOR FURTHER INFORMATION CONTACT: waiver request is available for review in Form Number: 8878–A.
James Reynolds by phone at 202–366- the docket. OPS is seeking comments on Abstract: Form 8878–A is used by a
2786, by fax at 202–366–4566, by mail the Enstar’s waiver request. After the corporate officer or agent and an
at DOT, PHMSA, Office of Pipeline comments have been received and the electronic return originator (ERO) to use
Safety, 400 7th Street, SW., Washington, comment period has ended, OPS will a personal identification number (PIN)
DC 20590, or by e-mail at consider each comment and make a to authorize an electronic funds
james.reynolds@dot.gov. decision whether to grant or deny withdrawal for a tax payment made
Enstar’s waiver request. OPS’ decision with a request to extend the filing due
SUPPLEMENTARY INFORMATION: The
will be published in the Federal date for a corporate income tax return.
pipeline safety regulation at 49 CFR
Register. Current Actions: There are no changes
192.321(e), Installation of plastic pipe,
requires plastic pipe that is not encased Authority: 49 U.S.C. 60118 (c) and 49 CFR being made to the form at this time.
to have an electrically conducting wire 1.53. Type of Review: This is a new
or other means of locating the pipe Issued in Washington, DC, on March 17, collection.
while it is underground. Tracer wire 2005. Affected Public: Business or other for-
may not be wrapped around the pipe Theodore L. Willke, profit organizations.
and contact with the pipe must be Deputy Associate Administrator for Pipeline Estimated Number of Respondents:
minimized but is not prohibited. Tracer Safety. 140,000.
wire or other metallic elements installed [FR Doc. 05–6730 Filed 4–5–05; 8:45 am] Estimated Time Per Respondent: 3
for pipe locating purposes must be BILLING CODE 4910–60–P
hours, 37 minutes.
resistant to corrosion damage, either by Estimated Total Annual Burden
use of coated copper wire or by other Hours: 505,400.
means. The following paragraph applies to all
DEPARTMENT OF THE TREASURY
Enstar is requesting a waiver from of the collections of information covered
§ 192.321(e) because lightning strikes Internal Revenue Service by this notice:
are rare in their service area, and Enstar An agency may not conduct or
believes there will be more, not fewer, Proposed Collection; Comment sponsor, and a person is not required to
incidents on their pipeline if they are Request for Form 8878–A respond to, a collection of information
forced to discontinue the practice of unless the collection of information
AGENCY: Internal Revenue Service (IRS), displays a valid OMB control number.
wrapping tracer wire around their
Treasury. Books or records relating to a collection
plastic pipe.
According to Enstar, the Bureau of ACTION: Notice and request for of information must be retained as long
Land Management (BLM) tracks comments. as their contents may become material
occurrences of lightning strikes to in the administration of any internal
SUMMARY: The Department of the
monitor forest fire activity. BLM has revenue law. Generally, tax returns and
Treasury, as part of its continuing effort
lightning detection systems throughout tax return information are confidential,
to reduce paperwork and respondent
Alaska in locations were lightning as required by 26 U.S.C. 6103.
burden, invites the general public and
strikes are frequent, mainly north and Request For Comments: Comments
other Federal agencies to take this
west of the Alaska Range. Lightning submitted in response to this notice will
opportunity to comment on proposed
strikes are recorded by electrical sensors be summarized and/or included in the
and/or continuing information
at nine stations in Alaska. Where request for OMB approval. All
collections, as required by the
lightning strikes are not common, such comments will become a matter of
Paperwork Reduction Act of 1995, Pub.
as south and east of the Alaska Range, public record. Comments are invited on:
L. 104–13 (44 U.S.C. 3506(c)(2)(A)).
lightning detection systems are not (a) Whether the collection of
Currently, the IRS is soliciting
installed. Enstar’s service area is in information is necessary for the proper
comments concerning Form 8878–A,
south central Alaska, an area without performance of the functions of the
IRS e-file Electronic Funds Withdrawal
lightning detection systems. Since 1972, agency, including whether the
Authorization for Form 7004.
Enstar’s standard practice has been to information shall have practical utility;
DATES: Written comments should be (b) the accuracy of the agency’s estimate
wrap tracer wire around their plastic
pipe. Because of the unique received on or before June 6, 2005 to be of the burden of the collection of
geographical and climatic conditions of assured of consideration. information; (c) ways to enhance the
the area, lightning strikes on their ADDRESSES: Direct all written comments quality, utility, and clarity of the
plastic pipe system are extremely rare. to Glenn Kirkland, Internal Revenue information to be collected; (d) ways to
In 32 years, Enstar has recorded only Service, room 6516, 1111 Constitution minimize the burden of the collection of
one confirmed incident due to lightning Avenue NW., Washington, DC 20224. information on respondents, including
strikes. FOR FURTHER INFORMATION CONTACT: through the use of automated collection
Enstar contends that their pipeline Requests for additional information or techniques or other forms of information
will suffer more damages if they are not copies of the form and instructions technology; and (e) estimates of capital
allowed to wrap tracer wire around their should be directed to Allan Hopkins, at or start-up costs and costs of operation,
pipeline. Enstar performs approximately (202) 622–6665, or at Internal Revenue maintenance, and purchase of services
500 excavations per year due to third Service, room 6516, 1111 Constitution to provide information.

VerDate jul<14>2003 18:17 Apr 05, 2005 Jkt 205001 PO 00000 Frm 00109 Fmt 4703 Sfmt 4703 E:\FR\FM\06APN1.SGM 06APN1

Вам также может понравиться