Академический Документы
Профессиональный Документы
Культура Документы
Spectrum devices help make actigraphy easier to use, the devices more
comfortable to wear, and the data acquisition and analysis functions less
Actiwatch 2
Actiwatch 2
Parameter
Size
Weight
Case material
Standard wrist band
Battery type
Logger battery life
Memory
Actiwatch Spectrum
Actiwatch Score
Logging interval
Epoch length
15 seconds
30 seconds
1 minute
5760
2880
1440
Typical value
43mm x 23mm x 10mm
16 grams (with band)
ABS blend (biocompatible)
Biocompatible BASF elastollan 1175A10W (TPU)
with titanium buckle accommodates
7mm hospital type band
Lithium cell (rechargeable at dock)
30 days at 1-minute epoch lengths
Non-volatile 1 Mbit
Logging time
(activity only)
22.7 days
45.5 days
91 days
Logging time
(activity and light)
7.5 days
15.1 days
30.3 days
Note: Device also records in two-minute and five-minute epoch lengths and in a light-only mode.
Accelerometer details
Type
Range
Bandwidth
Sensitivity
Sampling rate
Silicon photodiode
400 900 nanometers
570 nanometers
Photopic illuminance in lumens/m2 (lux)
5 100,000 lux
10% at 3000 lux (typical)
Environmental attributes
Moisture protection
Operating temperature range
Resistance
Actiwatch Spectrum
Parameter
Size
Weight
Case material
Standard wrist band
Typical value
48mm x 37mm x 14mm
30 grams (with band)
ABS blend (biocompatible)
Biocompatible BASF elastollan 1175A10W (TPU)
with titanium buckle
CR 2430 lithium coin cell (factory replaced)
240 days with continuous use
Non-volatile 2 Mbits
Battery type
Logger battery life
Memory
Logging interval
Epoch length
15 seconds
30 seconds
1 minute
5760
2880
1440
Logging time
(activity only)
45.5 days
91 days
182 days
Logging time
(activity and RGB light)
9 days
18 days
36 days
Note: Device also records in two-minute and five-minute epoch lengths, in photopic light-only mode, and in an
RGB light-only mode.
Accelerometer details
Type
Range
Bandwidth
Sensitivity
Sampling rate
Light sensor details
Type
Wavelength range
Measurement units
Irradiance range
Accuracy
Off-wrist detector
Sensor
On-wrist activation range
Capacitive
<2mm
Environmental attributes
Moisture protection
Operating temperature range
Resistance
Actiwatch Score
Parameter
Size
Weight
Case material
Frame & battery cover
Standard wrist band
Battery type
Logger battery life
Memory
Logging interval
Epoch length
15 seconds
30 seconds
1 minute
Typical value
37mm x 35mm x 12mm
25 grams (with band)
Glass filled nylon
Titanium
Nylon with buckle
CR 2025
3 months
32kb
Logging time
5.5 days
11.1 days
22 days
Note: Device also records in two-minute and five-minute epoch lengths. Logging
time varies with programmed alarm schedule.
Accelerometer details
Type
Cantilever beam piezo-electric
accelerometer
Range
0.5 2 G peak value
Bandwidth
3 Hz 11 Hz typical
Sampling rate
32 Hz
Scorepad details
Scoring leads
0 15 user selectable
Number of scores One
per epoch
Environmental attributes
Drip tight
To IEC standard 60529 IPX2 (resistant
to dripping and light splashes of liquids)
Computer and communications
Hardware platform Pentium II or later
personal computer
Operating system
Actiware: Windows 7, Windows XP or
compatibility
Windows Vista; Actiware CT:
Windows 7, Windows XP Professional,
WindowsVista Business or Windows
Vista Ultimate
Battery type
9 V lithium
Philips Respironics
1010 Murry Ridge Lane
Murrysville, PA 15668
Customer Service
+1 724 387 4000
800 345 6443 (toll free)
Respironics Europe, Middle East, Africa
+33 1 47 52 30 00
Respironics Asia Pacific
+852 3194 2280
www.philips.com/respironics
North America
+1 425 487 7000
800 285 5585 (toll free, US only)