Вы находитесь на странице: 1из 19

Bonnenberg

+ Drescher
Projektentwicklung GmbH

acoustic gas temperature measurement


system agam

Bonnenberg + Drescher
Projektentwicklung GmbH
Industriepark Emil Mayrisch
D 52457 Aldenhoven

manfred.deuster@budi.de
www.info@budi.de
Telefon: 0049-(0)2464-5810
Fax: 0049-(0)2464-58136

Bonnenberg
+ Drescher
Projektentwicklung GmbH

C =

.R
.T
M

speed of sound

true" gas temperature

molecular weight

universal gas constant

specific heat

T = 1000 C

C = 686 ? m/s

Bonnenberg
+ Drescher
Projektentwicklung GmbH

temperature = 1000 c
speed of sound = 686 ? m/s

gas composition (lignite)

CO2
O2
CO
H2 O
dust

=
=
=
=
=

18-14 Vol. %
2 - 6 Vol. %
100-1000 mg/Nm3
19-21 Vol. %
10-15 g/Nm3

5 m/s

unaccuracy < 1,5 %

Bonnenberg
+ Drescher
Projektentwicklung GmbH

C =

.R
.T
M

4 Transceiver, 6 paths

6 Transceiver, 12 paths

8 Transceiver, 21 paths

8 Transceiver, 24 paths

acoustic gas temperature


measurement system

Bonnenberg
+ Drescher
Projektentwicklung GmbH

Bonnenberg
+ Drescher
Projektentwicklung GmbH

Transceiver unit
6

Bonnenberg
+ Drescher
Projektentwicklung GmbH

transition cone

Bonnenberg
+ Drescher
Projektentwicklung GmbH

Transceiver unit
above SNCR
Transceiver unit
below SNCR
8

Bonnenberg
+ Drescher
Projektentwicklung GmbH

PCU

Auenansicht

Innenansicht
Rckwand

Innenansicht
Tr
9

Bonnenberg
+ Drescher
Projektentwicklung GmbH

PCU and evaluation unit (2 lines)


(19 rack)
10

Bonnenberg
+ Drescher
Projektentwicklung GmbH

Evaluation unit
(19 rack)
11

Bonnenberg
+ Drescher
Projektentwicklung GmbH

3 evaluation units
(one 19 rack)
12

Bonnenberg
+ Drescher
Projektentwicklung GmbH

waste

aux. Burner
(gas)

Bi directional measurement of an acoustic path

13
13

Bonnenberg
+ Drescher
Projektentwicklung GmbH

14

Bonnenberg
+ Drescher
Projektentwicklung GmbH

15

Bonnenberg
+ Drescher
Projektentwicklung GmbH

furnace exit

100 m
OFA 3

OFA 2

OFA 1

burner level 2
30 m
burner level 1

configuration at the furnace exit in 800 to 930 MWel.


lignite with display of temperature results (isothermal
map and deviation from average in 4 zones),
16

Bonnenberg
+ Drescher
Projektentwicklung GmbH

1200

temperature in C

1100

1000

900

800

700

without agam control

with agam control

23:41

22:56

22:10

21:26

20:42

19:58

19:14

18:30

17:46

17:01

16:15

14:47

13:12

11:34

09:55

08:16

06:37

04:58

03:18

01:39

00:00

600

time

results of temperature balancing control in waste to energy (AZN Moerdijk)


17

Bonnenberg
+ Drescher

T in K

Projektentwicklung GmbH

Frontwall
5

Backwall

temperature differences between front and rear wall in a hard coal furnace
18

Bonnenberg
+ Drescher
Projektentwicklung GmbH

acoustic gas temperature measurement


system agam

Bonnenberg + Drescher
Projektentwicklung GmbH
Industriepark Emil Mayrisch
D 52457 Aldenhoven

Your Local Contact:


Hitech Systems & Services Ltd
White House 119,Park Street
Kolkata-700016 India
Tel;91-11-22290045 Fax;91-11-22291264
E-mail: info@hitech.in
web:www.hitech.in
19

Вам также может понравиться