Академический Документы
Профессиональный Документы
Культура Документы
12
12
13
14
18
18
18
19
19
April 2002
To operate an LE 4xx PA/PB with the SIMODRIVE inverter system you need
the following components.
n Protective PCB
n Expansion board depending on the options
UV 105
Power supply
Power consumption
Approx. 300 W
Degree of protection
IP20
Weight
4.1 kg
ID number
344 980-xx
Changes to UV 105
344 980-01
Initial version
344 980-02
344 980-12
Designation
ID number
324 955-xx
359 002-xx
Initial version
324 955-04
Improved EMC
324 955-14
Initial version
313 437-04
Improved EMC
359 002-01
April 2002
Initial version
324 952-02
324 952-03
324 952-10
324 952-11
5.35 V
100 mA
175 mA
+15 V
75 mA
90 mA
-15 V
1 mA
2.5 mA
(1-axis version)
(2-axis version)
Enabling of safety 20 mA
relay
Unit bus pin
20 mA
5.35 V
175 mA
+15 V
90 mA
-15 V
2.5 mA
Enabling of safety 20 mA
relay
Maximum current consumption of the SIMODRIVE power module from the
SIMODRIVE infeed/regenerative feedback module:
SIMODRIVE
power modules
Activation of
power transistors
Power for
fan
6SN1123-1AA00-0HAx
125 mA
6SN1123-1AA00-0AAx
125 mA
6SN1123-1AA00-0BAx
125 mA
6SN1123-1AA00-0CAx
125 mA
125 mA
6SN1123-1AA00-0DAx
125 mA
100 mA
6SN1123-1AA00-0EAx
125 mA
200 mA
6SN1123-1AA00-0FAx
125 mA
300 mA
6SN1123-1AB00-0HAx
250 mA
6SN1123-1AB00-0AAx
250 mA
125 mA
6SN1123-1AB00-0BAx
250 mA
125 mA
6SN1123-1AB00-0CAx
250 mA
100 mA
ID number
The 20-pin round cable connects the outputs of the LE 4xx M or CC 42x with
the corresponding interface cards in the SIMODRIVE 611 D or the power
modules of the POWER DRIVE. One cable is required for each axis or spindle.
Note
The 20-pin round cable is needed only for the double-row design.
ID number
1m
360 888-01
2m
360 888-02
3m
360 888-03
4m
360 888-04
5m
360 888-05
7m
360 888-07
The 20-pin ribbon cable connects the outputs of the LE 4xx M or CC 42x with
the corresponding interface cards in the SIMODRIVE 611 D or the power
modules of the POWER DRIVE. One 20-pin ribbon cable is required for each
axis or spindle.
Note
The 20-pin ribbon cable is needed only for the single-row design.
You can calculate the length of the required 20-pin ribbon cable as follows:
April 2002
Add the width of all modules (including the UV 105 and installation kit)
between the LE 4xx M or CC 42x and the power module for which the cable
length is to be calculated.
Add to this total width the width of the power module for which you are
calculating the cable length.
From the following table, select the next longer cable length
(only LE 430 M/9 axes and CC 42x with more than 6 control loops: cable
length after the next).
Width
6SN112x-1AA00-0HAx
50 mm
6SN112x-1AA00-0AAx
50 mm
6SN112x-1AA00-0BAx
50 mm
6SN112x-1AA00-0CAx
50 mm
6SN112x-1AA00-0DAx
100 mm
6SN112x-1AA00-0EAx
150 mm
6SN112x-1AA00-0FAx
300 mm
6SN112x-1AB00-0HAx
50 mm
6SN112x-1AB00-0AAx
50 mm
6SN112x-1AB00-0BAx
50 mm
6SN112x-1AB00-0CAx
100 mm
Width
HDD12.2-W040N
50 mm
HDS12.2-W040N
50 mm
HDS13.2-W075N
100 mm
HDS13.2-W100N
100 mm
HDS14.2-W200N
150 mm
ID number
100 mm
250 479-07
200 mm
250 479-08
300 mm
250 479-09
400 mm
250 479-10
500 mm
250 479-11
600 mm
250 479-12
700 mm
250 479-13
800 mm
250 479-14
900 mm
250 479-15
1000 mm
250 479-16
1100 mm
250 479-19
1200 mm
250 479-20
1300 mm
250 479-21
Add the width of all power modules (for widths see 20 pin ribbon cable)
From the following table, select the covers that you need to attain the
calculated total width.
ID number
50 mm
329 032-05
75 mm
329 032-06
100 mm
329 032-10
250 mm
329 032-25
Designation
ID number
340 181-01
Warning
Ensure that the unit bus on the infeed/regenerative feedback module is
completely covered.
April 2002
X1
PWM, axis/spindle
X351
Warning
Do not engage or disengage any connecting elements while the unit is
under power!
Note
The signal ground (X131) of the SIMODRIVE inverter must connected with
the central signal ground of the machine!
Up to Id. Nr. 324 952-03, the signal ground (X131) of the SIMODRIVE
inverter must connected with the central signal ground of the machine!
To ensure noise immunity, HEIDENHAIN recommends against mixed use
of the interface cards Id. Nr. 324 952-10 (A)/11 and Id. Nr. 324 952-03/02/01
10
April 2002
Pin layout:
D-sub connection
Assignment
Do not assign
PWM U1
PWM U2
PWM U3
Reset
Ready
Iactl 2
Iactl 1
0 V U1
10
0 V U2
11
0 V U3
12
0 V (analog)
13
ERR
14
+Iactl 2
15
+Iactl 1
Housing
External shield
11
+5 V 0 V
Terminal
5 V power supply
Ribbon cable
X69
X31
Power supply
Warning
Do not engage or disengage any connecting elements while the unit is
under power!
12
2.2.2 Connections
Danger
The UV 105 power supply unit must be opened only by HEIDENHAIN
service personnel.
Do not engage or disengage any terminals while they are under power.
The UV 105 has a 50-line ribbon cable for power supply to the LE 4xx M or
CC 42x.
It is your responsibility to protect the infeed lines of the dc-link voltage from
the SIMODRIVE 611 D to the UV 105. HEIDENHAIN offers a protective PCB
(Id. Nr. 296 965-01) for installation in SIEMENS infeed/regenerative feedback
modules. This PCB has four A/500 V fuses.
X31: Supply voltage
of the UV 105
Assignment
Ua
V
Equipment ground (YL/GY)
April 2002
13
2.2.3 Dimensions
14
X73
Enabling connector
Grounding conductor (connect with the central
grounding point of the machine)
SH1
Pulse release disabled (red)
SH2
Pulse release disabled (red)
READY Ready for operation (green)
Sliding switch (1-axis version):
Input for PWM signals: X111 or X112
1-axis
version
X111
PWM, axis/spindle
X112
PWM, axis/spindle
X351
2-axis
version
Warning
Do not engage or disengage any connecting elements while the unit is
under power!
Note
The signal ground (X131) of the SIMODRIVE inverter must connected with
the central signal ground of the machine!
April 2002
15
2.3.2 Connections
X73 Enabling
connector
Pin layout:
Terminal
clamp
Assignment
Old
designation
Note
24 V
K9
K663
0V
ON
Do not assign
Do not assign
6a
OE1
AS1
7a
OE2
AS2
a. max. 125 V
Warning
A recovery diode is required in the proximity of inductive loads, e.g. relay or
contactor coils.
16
April 2002
Pin layout:
Ribbon cable connector 20-pin
Assignment
1a
PWM U1
1b
0 V U1
2a
PWM U2
2b
0 V U2
3a
PWM U3
3b
0 V U3
4a
SH2
4b
0 V (SH2)
5a
SH1
5b
0 V (SH1)
6a
+Iactl 1
6b
Iactl 1
7a
0 V (analog)
7b
+Iactl 2
8a
Iactl 2
8b
0 V (analog)
9a
Do not assign
9b
BRK
10a
ERR
10b
Ready
17
18
3.1.3 Mounting the Protective PCB in the Infeed/Regenerative Feedback Module of the
SIMODRIVE 611 D Inverter
Fasten the protective PCB in the infeed/regenerative feedback module with
the provided mounting panel
Infeed/regenerative
+
+
Protective PCB
To the UV 105 or
LE 4xx PA/PB
X131
U1
V1
W1
April 2002
19
UV 105
HEIDENHAIN
interface card
Unit bus
PWM
PWM
Covers
Adapter connector
Power supply
20
UV105
+Uz
Uz
PWM
Covers
PWM
Adapter connector
Power supply
April 2002
21
HEIDENHAIN
interface card
Unit bus
PWM
Covers
UV 105
Uz
LE 4xx M
CC 42x, MC 422
Housing
+Uz
Maintain the
minimum spacing
between rows!
Covers
PWM
Adapter connector
22