Вы находитесь на странице: 1из 4

Outdoor Cross-Connect Cabinet GP31-2-A1X-2

Fiber Optics Outdoor Cross-Connect Cabinet


--- Wall Mount Style

(LongXing Ref: GP31-2-A1X-2)

GP31-2-A1X-2 Outdoor cross-connect cabinet is the best choice for cross-connecting outdoor optical
cables. The cabinets offer ideal environment for fibers to be spliced and well organized under any
outdoor environments.

Characteristics
The cabinet has functions of cable termination, splicing, distribution and cross-connection.
Body material options:
Cold rolled steel with electrostatics plastic-spray surface
Stainless steel with electrostatics plastic-spray surface
Excellent waterproof and dustproof performance.
The central board (for adapters) separates the incoming cables and the exiting cables.
Splice trays can be turned over, also can be pulled out to operate outside the box, easy to
increase capacity (when space is enough).
Adapters are installed on our 6-position adapter holders, no screws need for installing any
type adapters, which is very easy for future maintenance and keeps the transmission loss at
low level.
Working temperature: -30C - 75C
Relative humidity:

90%(at 30 C)

Insertion Loss(IL):

PC0.35dB, UPC0.30dB, APC0.20dB

Return Loss(RL):

PC45dB UPC50dB APC55dB

Updated on 14 Aug 09
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation
of LongXing is indicative only and shall not be binding on LongXing or be treated as constituting a representation on the part of LongXing.

Outdoor Cross-Connect Cabinet GP31-2-A1X-2

Features Descriptions

Locks provided on ever


cabinet ensures the
safety of the fibers.

Each cable will be


fixed properly and
earth protection is
also provided.

The central plate can be moved


out for easier installation and
operations of the adapters on
the bottom. (Available with large
capacity cabinets only)

Order Guide
Connector Type

FC/SC Simplex Adapter

LC Duplex Adapter

Dimensions

W x D x H (mm)

Core Capacity

Cable Port (Max)

480*480*110

12

480*480*130

24

480*480*150

36

480*480*170

48

480*480*220

72

480*520*270

96

480*480*110

24

480*480*130

48

480*480*150

72

480*480*170

96

Updated on 14 Aug 09
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation
of LongXing is indicative only and shall not be binding on LongXing or be treated as constituting a representation on the part of LongXing.

Outdoor Cross-Connect Cabinet GP31-2-A1X-2

Test Report on the Cabinet


Sequence
Inspection Item

Requirement

Inspection Results

Conclusion

Number
Shape integrity, no defect, no burr,
no bubble, no crack, no impurity,

Meets the

no hole, color uniform, easy to

requirements

Appearance

Qualification
close and open
Electric connecting or shut off

Appearance and

Electric Connecting

configuration

Set

Meets the
section in the box, ground lead-out

Qualification
requirements

section on the external shell.


Residual fiber length no less than
>1.6m
Optical Fibers Storage

1.6m

Set

Residual fiber curvature Radius no

Qualification
>37.5mm
less then 37.5mm
Meets the
2

Function

YD/T 925-1997

Qualification
requirements

Axis Tensile

Between cable and case500N

>500N

Between cable connector and case5N

>5N

200N

Crush

Qualification
Meets the
Qualification
requirements
Meets the

Torsion

90C,3cycles,1min

Qualification
requirements

High Temperature

(752)C,2h,after test at room temperature condition for

Color uniform, no

Test

2h,color uniform, no loss increase

loss increase

Low Temperature

(-253)C,2h,after test at room temperature condition for

Color uniform, no

Test

2h,color uniform, no loss increase

loss increase

(302)C(853)%,2h,after test at room temperature condition

Color uniform, no

for 2h,color uniform, no loss increase

loss increase

Qualification

Qualification

Damp Heat Test

Qualification

Insulated

Insulated

Resistance

Resistance2x104M

Between two metal sections

1X106 M

Between metal section and ground

1X106 M

Between two cable

1X106 M

Qualification

No breakage No
Between two metal sections
electric arc
DC 15KV holding
Voltage Resisting
10

No breakage No
Between metal section and ground
electric arc

1min,No breakage,no

Qualification

Strength
electric arc
No breakage No
Between two cable
electric arc

Updated on 14 Aug 09
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation
of LongXing is indicative only and shall not be binding on LongXing or be treated as constituting a representation on the part of LongXing.

Outdoor Cross-Connect Cabinet GP31-2-A1X-2

Testing on Adapter SC/PC, FC/PC Simplex of ODF


Sequence

Inspection

Number

Item

Requirement

Inspection

Conclusion

Results
After testing to

11

Durability

500times

IEC61300-3-3.Method

0.18dB

Qualification

0.17dB

Qualification

0.19dB

Qualification

0.17dB

Qualification

0.16dB

Qualification

1<0.2dB
After testing to
IEC61300-2-1 to
12

Vibration

IEC61300-3-32.Method
5~500 Hz(2hr)
1<0.2dB
After testing to
IEC61300-2-9

13

Impact

IEC61300-3-32.Method
1.5M drop,8times
1<0.2dB
After testing to

Temperature

-25~+75C

Cycling

(42Cycles)

14

IEC61300-3-32.Method
1<0.2dB
After testing to
Humidity

15

75C,95%/336hr

IEC61300-3-32.Method

Cycling
1<0.2dB

Contact:
International Trade Department, LongXing Telecom
407, Mingzhu Rd, Hi-tech Park, Ningbo, 315040, China.
Direct:

+86 574 87917627

Fax:

+86 574 87908188

Email:

info@nblxtelecom.com

Web:

www.lxtelecom.com

Updated on 14 Aug 09
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation
of LongXing is indicative only and shall not be binding on LongXing or be treated as constituting a representation on the part of LongXing.