Вы находитесь на странице: 1из 24

Direct Drive NON-MERCURY

FILLED TYPE TEMPERA TURE

~[Jj}@~

~WDll~!JD~

HIGH
QUALITY.
REPEATABILITY.
DUABILITY.

The NEss thermometer is superior to other systems because it pro


vides an evenly graduated scale without the use of a multiplying
mechanism or delicate geared segments, pinions or h3ir springs.
The pointer action is direct drive with no multiplying mechanism.
This results in a most rugged instrument suitable for installations
which, by necessity, have severe vibration and shock.
The mechanical difference between the NEss tht'rmometer and a
conventional type thermometer is shown in Fig 1.
Because of its

"gearless" mechanism, the" NEss" thermometer as the followinC] advantages as

compared with conventional type thermometers.


1. Excellent stability.
2. Less trouble because of its simple mechanism.

3. MorA dlJrability against vibration and shock.


4. Smoother movement of pointer action.
5. Greater sensitivity and faster response to changE.'s in temperatures.
6. Better accuracies.
Compensations Bimetal oJrnpensator for head 3nd line as unit, correc ts for a.mbip.nt temperature

change.
Double lead compensator (consists of two bourdon tubes and capillary tubes)
available if specified.

INTERIOR MECHANISM
THERMOMETER
Housing
Driving Shaft

Capillary Tube
Bimetal Compensator
Bourdon Tube

Sensing
Bulb

Zero-Adjust
Capillary Tube

Scale Plate
Capillary
Pointer

Crystal
-------
Covering Ring

Gasket

* CONVENTIONAL

TYPE MECHANISM

NESS THERMOMETER MECHANISM

SIDE VIEW of N-type Bourdon Tube

CD

- @

(4)

CD

CD Pointer

Compensator (standard)

Pointer

~ C-type Bourdon

@ N-type Bourdon Tude

@ Gear Mechanism
@ Hairspring

@ Adjustment

NEss

THERMOMETER
Use No Gear

Gear Mechanism

Conventional-type THERMOMETER

Fig.

STANDARD SPECIFICATIONS

(applicable on all models except "AGNESS", Compact type & Eccentric type)

CASE"

Case ar black enameled cast aluminum, glass cry tal and "0" ring seal

Standard model is case compensi'lted. Double capillary, case and line compensated, are also available.

304 stainless steel cases are available as an option. 316 stainless steel case is availi'lble for 6" dial size only.

DIAL

Black numbers on While dial.

White on Black is available as well.

Three dial sizes 3" (75mm), 4" (lOOmm), 6" (lSOmm) nominal.

CAPILLARY

3m (1 Ofeet) 304 stainless steel tube in 304 stainless steel flexible armor is sli'lndard. Maximum length lor liquid

filled guaQes is 10m (33feel), 30m (98feel) for gas filled gauges and 50m (160feet) for double capillary line

compensated type.

SENSING
BULBS

Low temperature gauge have 1Omm diameter x 1OOmm length standard bulbs With 1/2" NPT sliding union con

nection, High temperature Qauaes, those ilhove 400"(, have 12mm x 1OOmm length bulbs with 1/2" NPT sliding

union connection. Available solid union, w/unlons, plain I)ulbs. and bulbs with lhermowells, Standard bulbs are

304 stainless steel. 3/4" unions are available as n oplion. Please refer to page 19 for details.

MOUNTING

Select back f1anae surlace mount, front flange panel mount. or LJracket mount.

Please refer to page 5-18 for details

DEGREE OF IP66 (Deck Watertigllt - IEC) Certified

PROTECTION
(ENCLOSURE)
ACCURACY

2% Full scale

OPTIONS

.31 6 stainless steel capillary and armor.


Bulb diameter and bulb lenqlh, consult representative.
Thermowells.
Connecting thread size or flange size.
Changing selling point inner or external set.
External junction hox.
Accuracy of 1% of rull scale (lor liquid filled type indicators only)

The indicator, capillary, and sensing bulb are a single unit filled with liquid or gas. These liquides or gases
will respond properly in spite of any peripheral temperature changes. The compensator exists in order to
dutomatically control any changes owing to temperature fluctuations in these liquids and gases, which are
highly susceptible to temperature changes under normal circumstances.

For Single Capillary Types


,,r-

---------------------,

,,
,,

CD.~
.
:

Because the compensator is housed within the case,


it j<:, rIt~cessary to keep the capillary at the same tem
perdture as the case. This type of compensator is
called a "Case Compensator" or a "Bi-metallic Com
pcn~~tor". Our Qduges having this type compenc,ator
have "S" at the end of their model numher.

CD Indicator
,I Compensating
.
,, auxiliary
Bourdon Tube
@
___________
J:
I

I
I
I
I
I

,
I

@ Case Interior
(5) Capillary
@ Sensing Bulb

/(5)

For Double Capillary Types

-------- ----.,

r-

I
I

,,,
,,

,
L

_
-

-.

,
J

,, CD Main Bourdon
,
Main Capillary
(3) Compensating
Bourdon

@ Auxiliary Capillary
@ Sensing Bulb

($1

In each gauge the bourdon tubes and the capillaries


are grouped into two sets. One set is for temperature
measurement, while the other set is for temperature
compensation. This gauge will compensate reliably
even under local temperature fluctuation.
This feature is called "Full Compensation" and places
this gauge a grade above gauges with so-called "CJ.se
Compensation" Our products having full compensation
have "D" at the end of their model number, those with
case compensation are likewise coded "S",

Examples of when "Full Compensator" is necessary


EX. 1

Great fluctuation in temperature "lolllJ


the periphery 01 the capillary when
here IS scarcely any empera ure
change on the indicator.

EX. 3
20C

LIQuid temperature measurement in a


tank With aned temperature
dlStnbutlon

____

~r._

- - - 4Q<::

---EX. 2

Great temperalure f1uclualiull" ill botll


the capillary and indicator.

r------,
,-1O-00C,
,,,
,,,
,
,
,
,
I

10 50 r.

FX 4

The Call1l1iHY experience~ nnn lJn,fnrm


temperature c:ondltinn~

r-----l

, 10 50'C'

:, CS)
\ :
I

,.---, ,.---, ,.---,

I
I

I oOC " 30e 11-IOe, L

.J

~c=

The temperature conditions illustrated above are for reference purposes


not limited to these.

I
I
I
I

II
II
II
II

II

II

II
II
II
II

I
I
I
I

I
I

-l

'----'

only~

the possible conditions are

"J \
:I. ~11~o/ll"
r, ~ '~~'
;. ,"I",
i
,
,

I'

,I I~J : " ,
t';!. f

I.

"

'j

r:

't,:

,I,

: lI'... ,

'

.L.

SCALE RANGE TABLE

Mod.No.
1-

Range in 'C

3"

4"

6"

Range in 'F

Mod.No.

Mod.No. Range dual in


,

* -200~+50

00

5
,

01

:~
-

5
I

*-100~+200

02
-~

03

2
t>

tt

04
05
06

-20~

80

07

13

14

0~120

62

0~150

10
12

* *0~100

64

32~300
- -

65

32~400

66

32~500

81

'

O'~ 150'C
32~300'F

82

-i!--

0~200'C

83

32~400'F

--
16

17

18
19

*0~400

10

10
-f--

50'C

-20~120'F

32~21 0

63

--

15

-30~

80

"..

09

--

61

08

10
.

20

*0~500

10

10

10

21

*0~600

10

10

10

68
I

69

84

r-.

0- 600C

*32~1112'F

* Gas Fillf,d
* * 1'C graduation

is available as an option (for 4" dial size only)


Ranges listed above are most frequently specified, Consult factory for special ranges,
Standard: Black lettering on White background.
If your application is of a special nature, let us know your exact requirements and our proven design and engineer
ing experience will he placed at your disposal.

I MODEL TUS-2S (FLUSH MOUNTING)


Model No ADl

Dia
--

3" 4"
6"

BIC

60

5
7
7

1.l2: 7~ j 6060

110 100 92
140 125 ~
93
206 190 168 140

I'b

Mal~

P Bron7e - -
Aluminum
NBR
Glass
Aluminum Alloy
Aluminum Alloy

PART NAME
1'0ll,le,
2 Scale Plate
3 - Gasket 4 Glass Disk
5 : Covering Ring
6 IlousinCl

[MODEL

TOS-2S

(FLUSH MOUNTING)

----

Model No AD2
3

~N

3"
4"

6"

c:

- 110' 100 t 92

70 60
. 140 , 125~1 11 2 93' 60
206 190 168
140' 60

I 57

Dia

"

11011511,0

Dia

3'
4'
G'
I'b
1

TBP-2

Glilss
AluminlJm Alloy
Aluminum Alloy

(PANEL MOUNTING)

I'

3 '
4

Al

B C 0
'110
100
I
92' 70

+.!:!O 125, 112, 93


.206 190 168 140

PART NAME
POlI,tpr
Scale Plate
Gasket
Glass Disk
(overillSJ R'ng
Housin

I MODEL TBP-3
',J

. '-.\

18
18
18

K
M
80 I 87
102' 106
154,158

F~

r:
f---.

r-Z7

MlmTnum

(PANEL MOUNTING)

Model No A05
Dia

''ji}~h-_

".

_ _~_--,Mrtlerial
P-8,ollze
~ITlinuln
NBR
Glass
Alia
Alumi'lUll1 Allo

............ l,-

3
4"
6"

A
C
I
' 110 I 92
: 140: 112:
206 168

0
70
93
140

18
18
18

60
60
60

'20

80 ~~
102 106_ 20
154 158 20
~

'

PART NAMF
POlllier
2 Scale Plale
3 ; Gasket

I'b
1

11ft'DISk
5 Covering Ring
6
Ilous,ng
7 T Mounllnn Kil

~f\J~R

Model No AD3

Mate'ial
l-c-:.BronLe
Aluminum

MODEL
s' J

I'b
PART NAME
1 Po,nlpr
2 I Scalp Plill!,!
3 Gasket
11 Glass Disk
5 Covering Ring

Material
P-Bronzc
Aluminum
NOR
Glass
Aluminum /\lloy
Aluminum AII~

30455

SU-AD-2

MODEL

(EVERY ANGLE)

Model Nn B05

4"
6'

112 93
1168 140

60
60

PART NAME
POinter
Scale Plate

f'b
1

",-,.,

Dia

c-

.J : G~kel
4

~I-

5
6

I Glass Disk

Zo
I K
11O;~(

154

1465

3" available

Material
_-+-,P,-,---=Br OllLe
Aluminum
NBR
Glass
Aluminum .:.:A:.:.:llo~_ _--1
Aluminum
304S-::'S'------

Coverrn R~
Iiousinf)
7 Stem
8 Locking Nut
9 Adjustatile Elbow Jornt
-1O~ Lockin Pin

304SS
Aluminum Alloy
304SS

I MODEL SBS-2

CONNECTIO~

(BACK

Model Nn B02
\

C
92

Dia

1.."

3"
4"
6"

PART NAME
Pointer
---

Add 4 inches
for high temp
Range Over
300'(

70
112 93
168 140

-.
tf
f'b

Material
P-Bronze

S cale Plate
---+-Aluminum
3 Gasket
~R
_
4
Glass Disk
I Gla.-=.ss=---_:-::-_
5 , Cnvp.ring Ring
Alumrnum Alloy
6 I Housing
I\luminum
7 RICjld SIP.m
304SS
8 ' Fixed Screw
30455

MODEL

5U5-2

(STAND TYPE)

Model Nn BOl

X
54+5
545
545

Dia

3'
4'

6'

f'b

,.J-'
4

5
6
7

-8

Material

PART NAMf:

, POinter

P-Bron~

--

Aluminum
NBR

Scale Plate
Gaskel
Glnss Disk
Coverin]LRirl.9..-
'1uusilly
Rrgld Stem
FIXed Scr~

MODEL

SUL-3

---

_.

---

~-

Aluminum Alloy
Aluminum
- 304SS
13045s-

(L STYLE)

Model No B06
Din

3'
4
6'
tt1

1
?
3
4
5
6

r
I&
60
fiO

PART NAME
POinter
Scale Plate
Gasket
Glass Disk

~_Cov(!llng
Housill

r1Tri9

-j-Zo

80
10?
154

1205
131 5
157t5

Add 4 inclles
for high temp
RanC)e Ovp.r
300'C

_ Materral
P-Bronze

I\lul1lrn~

NBR
, Glass -

I\IUl1lim111l Alloy _ _
Alurnillum

AGNESS-II

THERMOMETER

SPECIFICATIONS

(Fig. 1)

.SCALE (Standard)

.BULB

Dial Size: 4 inch (Nominal)


CODE No.
005

-30~

70'C

2'C

008

o~

50'C

1'C

010

0~100'C

2'C

0~150'C

2'C

0~200'C

5'C

0~300'C

5"C

012

TYPE

CODE

Sliding union
type (Std)

C
L

--

Please note that sliding union-type bulbs have


no effect against r>rp.SSlJrl~. If yOlJ put the bulb on
pressurized vessel, please use thermowell for
your safety.

013
015

1/2"NPT Thread Std.

Min. Grad

RANGE

If your application is of a special nature,


let us know your exact requirements and
put "X" at the end of Part Number

~,

8m/m

10m/m (Std.)

SUS304

S6 : SUS316

Outside diameter

6m/m

Code of Material

S4

~o

,"t

'I'
---~7

"

.~

. \.,

. i'll

Ii:'.', :

"~I

, J:'

I.,'

PART

NUMBERING

SYSTEM

In case of Std. Spec

Ex.-l

AGNESS- II

Optiunal Urder

I-I

010

I-I

I-I'----;-X-JI-I

Ex.-21-AG-N-ES-S--II

S4

I-I

10

I-I

150

I
Ex)

S6

I-I

I-~-~

~ Thermo bulb length in m/m


- - - - - - - - O D . of thermo bulb in m/m
Material of thermo bulb
Xl: Black letter in White
' - - - - - - - - - Code No. of Range (Fig-l)
X2:Scale range 32-210F
X3 :Thermowell (as per
' - - - - - - - - - - - - - - MODEL
another drawings)

*Previous Model AGNESS is still aVi.lilabc (100mm, 150mm)


Please consult your sales agent for details.

;"---0_--.

MODEL

TUL-20

(FLUSH

~OUNTING)
Model No A09

,or ( ) )

No

I
,

'0

15
,,
10

-~

1
2

PART NAME
Pointer
Scale Plate
--

~ -

3 r:asket
4
Glass Disk

- 5 I Covering Ring
6 _ Housing

[ MODEL

~N

Matenal
P-Bronze
Aluminum
NBR

- --Glass

Aluminum Allay

Aluminum Alloy

TU.-2S-0

(FLUSH MOUNTING)

Model No A07

6" aV3ilabic
PART NAME
Pointer
Scale Plale
-~ Gasket
4 GI3SS Disk
~ I Covering Ring
6 I Housin.Q.

Material
P-f\rnn7P
Aluminum
NBR
Glass
Aluminum Allay
Aluminum Alloy

No,
1
2

MODEL
I

TBP-30

(PANEL

MOUNT~N~~
Model No AOa

No
1

I'ART NAME
Pointer

Matcri~ _ _

P-Bronze
~2---t-is~c'-:a+:le-=;p~l:-:at--=-e~~~~-----r--l';:A;:-'Iu==m"=in"'"u=-m
Gaskel
NBf<
~~~~_I
Gldss Oisk
Glass
~
CovprinCj Rinq
Aluminum AII~
1-"6c--5crew
130455
7 Ilousrng ~~~~~~!I:;;-luc-;-m;;;in~u",m--,-,----:A;I.:.::I-O'-!..y-_-_-_-_-_-_-1_1
8
FIXing Nut
__ + 30455
9
Panel Mountinf) Kit
304SS
3
4

! MODEL SU-AD-20

(EVERY ANGLE-)

Model No B09

.110

PART NAM[
Poinler
2 Scalp Plale
3 G.lsket

4 Glass O;$k
Coveflng Rrng
6 Screw
7- Housrng
Locking Nul
9 I Adjustable E:lbow joinl
10 I Luckin\) PH'

Material

P Bron?'"

Aluminum

~NBR

Glass
AI minum Alloy
30455
Aluminum Allo_y_ _
304S5
I\ILJ.Inmum Allcry_
30455

ra

585-20 (BACK CONNECTION)

MODEL

Model No B08

A d 4 rnches

33' 93

545

for hrgh lemp


1*Rdnge
Over
300C

Pi\RT Ni\ME
rainier
2 Scale Plale
3 Gaskel - 4 Glass Disk
5 I Coveflng Ring
6 5crew
7 : IiouSH19
8 Union Nul

110
1

Aluminum Allay
30455
I Ali7minLlm Alluy
30455

30455

SUS-20 (STAND TYPE)

--

Model No B07

".

I Glass

MOlll1tlng Scrt:w

MODEL
,

Malerial

Bran?'

---I\lumlnllm

- -' NBR

,P

Dia
4

133

93

I - I
X
54+5

;dd 4 Inches

for high temp

L---'-_--''''''----'''''--'L-''-'-=:.::.......J Range Over

30m::
110
1

2
3

4
G
Covering~

8
9

~rial

PART NAME
Pointer
5calp PlaiR
Gasket
Glass Disk

Screw
Hou5,n'l
Union ul
Mounllng Screw

P Bron7f~ - - Aluminum
NOR
-.
Glass

Alilillinum Alloy

~04SS

Aluminum Alloy
304SS
--304SS

- -

I MODEL TUL-HSP

80

(FLUSH MOUNTING)

Model No Al0

4" stanr!;wi.
6" available

f\O

l~ ~I"
i'
',I'

...

'd,n .

1
2
3
4

5
6
7

I POinterPART NAME

Material
P Bronze
Aluminum
AIIJminum Allov

SCilie Plate
Converi,~inq

Alumfnurn~

Iiousing
Oillnlel
Oil Inlet Cap
Mounting Kit

Aluminllm Allov
AhJminllm Allov
304SS or Steel

"

_MODEL

"

TBP-HSP

(PANEL

MOUNTING)~
Model No A28

4" only.

f\O
1
2
3
4
5
6
7

>
..)

..

,,'

,.

Material
f1-BJOnzc
Aluminum
Ah~minum Allov
Aluminum Allov

PART NAME
Pointer
Scale Plate
Coverin Rin
Housll~

Alu'!1inulT~oy

0iflnlel
Oil Inlel Cap
Mountlnq Kit

Aluminum Allov
304SS or Steel

PANFl ("III

MODEL

SU-AD-HSP

(EVERY ANGLE)

Model No 812
4" only.

No

PAm NAMI:1 I Pointer


2 Scale Platl';
3 Covering Ring
4 . Locking Nut
G Adjustable [I bow

Joint

f)
Shaft
(
Lockm Pin

8 : Oil Inlet Cap


011 Inlet
9
10 Housing

n\ . .'

MODEL

"1

Material
P-Bronze
-Aluminum

--

AlllminlJl'fl.~

304SS
Aluminum Alia
-304SS

:1045S

- ~lTli!!!:'.r:nAlloy

Aluminum Alia
Aluminum Alloy

SUS-HSP

--

(STAND TYPE)

--

Model No 816

...~ :0..

,
r

~.~
-{ff~

TIl

4" only.

PART NAME
I'ointe'

Malerial
P-Bronze

5cillel-'l~

AiurnH1Ulll

No

3 : CoverinlL Rin
Oil Inlel Cap
4

5[

';0'"

6
7
8
0-+

011 Inlel
~--=-=-Iiousino
Rigid St~
Union Nut
Mounting Screw

Alumlnllm
: Aluminum
Aluminum
. Alu~1ll
304SS
304S5
t 30455

Allo
Alloy_
Alloy
Alloy

Add ~ incllcs
for high temp
Range Over
::lOOt.:

10

I he temperature switch encloses one or two electrical S.PD.T contacts which are adjusted to create ON
or OFF signal(s) when temperature reach(es) at the desired set point(s).

MICRO SNAP ACTION SWITCI j:

Set point
-ME

2 Set points
-MEE

Pushing opE~ration of small actuator can switch comparatively larger current betcen ON
and OFF. As a cam is installed on the pointer, a lobe is located to push switch's actuator.
As the temperature reaches the predetermined level, the lobe pushes the actuator for ON
or OFF action. The standdrd option i~-; SP.D.T(Single Poll" Double Throw.) For 2 contacts,
2 sets of cams & switches are used.

INTERIOR MECHANISM
For Single Capillary Types

["pilla

For Double Capillary Types


Hourcfon Tllbe

TLJhe

D,st"nl Piece

Compensator / /

//

,/
Center G_car /
Cam Gear//
Sellin Gear

~...

Selllnq Gear
. \ Set Screw

11

The following thermometers are especially designed to signal or control when temperatures go beyond
predetermined high or low limits, and at the same time give accurate temperature indications.
Up to 2 circuits can be controlled by one instrument with one or two switches installed as speCified.

Micro Switch
MOD CODE (one set point),(two set points)

Contact Capacity

5A 125V AC

Max Voltage Used

Withstand Voltage

Housln~ and

-ME, -MEE
non-,ndUCllvP

200V AC

Trrrrllllill

Number of contacts available

2000V AC 1 min.

1 S.P.D.T/ Set Point

12

TUS-2S-ME

MODEL

Model Nn C01

Dia

3"

4"
6"

A
B
C D N
110 100 92 70 ~
1'10 125 11~ ~ 7206 190 168 140 7

cp .,

......

No.
1

.-l
4
5
6

, -.'u

..

...

Material

PART NAME
Pointer
Scale PicHe
Gasket
Glass Disk

Covelinq Rlllq
HouSIng

Ter~

8
9

Set POint Indicator

Set Screw

~ronle

Al'Jminum
Neoprene

Glass ~
Aluminum AI'-'--Io~--
Aluminum AII(''-')Y~_ _--I
Pllcnol resl'-.n-,_

Brass Coated

Brass Coated--

TBP-2-ME

MODEL

Model Nn C03

'[

... .. 1

Dia

..

3"
4"
6"

No.
1
2
3
4

_;-

!~ c I D

: 11 0 ~ 100 92 70: 18
140 125 112 93 18
: 206 190 168 140 18

Gla,;s Disk
Ring

Sct Point Indicator

I MODEL

+--s
7
7

TBP-3-ME
Model Nn C05

Dia
4"

6"

No.
1

2
l.

D:I

II
C
140 ' 1J2' 93
~ 206 ' 168 '(40

8
9

Material
PBronze
---_.
AtuminlJnl
Neoprene
--Glass
Aluminum Alloy
Aluminum Alloy
Phenol resin
Brass Coatcd
Brass Coated

PART NAME
POinter
: Scalc Plate
Gasket
Glas~ Dd
Covcrrnq Rlnq
~IIOuSln'1
Tprminal
Set Point Indicator
Sct Scrcw

MODEL

F
J
K M
1A A5: 102/106
IA 8t> I')4 15fl

r--=L'
5
.6

Aluminum
eOflfene
GIi1sS
Aluillinum Alloy
Ailiminum Alloy
Phenol rpsin
Brass Coaled

7 ' Telminal

80, 87
102 106
1!A'I58

Material
; P-Bronze
---

PART NAME
POlnte=::r,--_ _
Scale Plate
Gasket
---

5 : (overing
6 Hou~iny

KIM

TBP-40-ME

'" ,

Model Nn C09

hl

...

4" only

No.
1

I,

-2 Gld" Di,k
~3 ~Coverir'.9. ,R-,i"-,n~y__
~us~

6
7
8

13

PART NAME

Gaske'"Ct~ ..; --

I ermlnal !:lox
Cable Wire outlet
Set I'oint Irldicator
S<.:t SLlCW

Mate~_

._-+...cN~e,-"o~Plre".'n"e,--__.

Gld"

~n1inufll Alloy
I-Aluminum Alloy
AluIlllnUIIl Alloy
!:lrass Coaled - - -
Brass Coated
01.1"' COdlL:LI

MODEL
Ora

No
1
2

3'

4'
6"

112
168

I 'T'r y ~O I X
70 8:'
25
54 t.5
93 i 85 ! 25 102
140 85
38 154 54 +-5
o

~+-5

PARI' NAME

~nLe

Scalc Plate
Gaskp.-.t--
Glass Drsk

~ COVerll1C) RTrlg

6 Housirlg
7 Rigid Stern
8 Union Nut
9 MOUllliliU Suew
10 lermrlh.ll
11 - Set Point Indicator
12 Set S~

*T:add 079 inchs (20 mrll) Iur twu ~el "ornts

*
Add 4 inches
for hiqll tcmp
Ranljc Ovcr
300'(

Material

, Pornter

3
<1

C
~92

SBS-2-ME

Aluminum
Neoprene
Glass
Aluminum Alluy
Aluminum
304SS
304SS
304SS
Phenol resin
Brass Coated
Brass Coated

I~M_O_D_E:::.L==S~U--r-S_----,2_-_M_E---..:::;-:-*--"-(S::..:.-.cPECIAL)
J'

-.

Oia
3'

4'
6"

70
. 112 93
168 140

'T
85
85
85

No

0.79 rnchs (20 mm) lor twu set points

f025415
1545415

PART NAMF
Pointcr
Scalp. Plate
3 Gasket--
4 (;las5 Uisk
. 5COVerrn Rin
6 : Hou:iirlg
1 Rrgid Stern
8 ; Unron Nut
1
Muunlir!9 Screw
.
lOTermrnal
'11 Set rointlndrcator - - ;
12 SP.t Screw
1
2

* Tadd

K
X
~ 545

MODEL

Add 4 rnches
for Iligh temp
Rilnge Over
300'C

Material
P-Bronze
Aluminum
Neoprene
Glass
Aluminum Alloy
Alurnirlu;n Alloy
304S5
304SS- -

304~

Phenol resin
Brass Coate-d--
Brass Coatcd

SUL-3-ME

(SPECIAL)

Oia

3"

4"

6"

No
1
2
3
4
5 .

6~
7
8
9
10
11 '

'T.ilrld 0.19 inchs (20 mm) for twu set "urnts

I"

I,.

PART NAM.
Pointer
Scale Plate
Gilskp.t
Glilss Disk
Covering Ring
Ilousrn
Riqid Stem
Elbow Joint
Set roint Indicator
Terminal
Sel Screw

MODEL

Material

P-Bron~

Alurnrnum - -
Np.o rene
I Glas_s__
~UIl2!!..'U'" Alluy
Alumrnum Alloy
. 304SS
Cast Iron or 304SS
Brass Coated
Phenol
re~inBrass Coated

SUS-50-ME

(SPECI~

Dial sizp. 3" only


Material
,~,
PART N.8ME
P-Bronze

Pointer
Aluminum
Scale Plate

3 Gldss Orsk-
Glass
4 Covp.ring Rin-g-
Aluminum Alloy

Alumi[lli;Tl
Alloy

5 Ilousin51.
~ Synlllelic resi-n--
6
I errninal Box

--+
--
7 SetPornt Indicator __ + ~ass Coat~

I:lrass Coatp.rl

8 SP.t Screw

+2

1r

* An order has

10

have 10 pcs or more

14

MODEL

TE02

Explosion Proof
Model No Cll

.-!-0'

.:", -'

I,ter

110

~!'

:')

fij):

liZ

j:

y~::

J,

~!

Conduct conn.
PF l/2 (Std)

@,'.

One set point or


(1 -SP.D.T)

(2) Scale range

See page 3

(3) C.lpillary

1m (Std).

(4) Thermobulb
TI1read
PT l/2 (Std.)

Slirling union typE.: only

,IL

,G"

Microswitch

,t\. ",

<:.~::~.

(1) Electrical
contact

Two set points


(2-S.P.D.T)

10m (Single capillary) Max.,

Material of Housing:

Aluminum

Electrical
rating

AC250V 3A (Non inductive)


AC 125V 5A (Non inductive)
DC 125V 0 AA (Non inductive)

50m (Double capillary) Max.

'" J
Material

S4:SUS304 (SLlndard)

S6:SUS316 (Available as optiun)

Uutside diameter:

8mm.

1 ?mm,

10mm.

(5) Please specify the following items for order


Item

For example

Model

TE02-ME-S

Scale range

O~

11

Outside diameter of thermobulb


Style of thermowell

<P

1 OO'C

10

BJPI 150LbRF x <P 15 x 200mm

Material of thermowell

SUS304

Electrical rating

ACl OOV 3A

Others

TAG No, Quantity, Order number, Other option

15

I MODEL TE03-ME
I

Explosion Proof

(Ex IIB+H,T4) Model Nn C14


.~

( 1) Electrical
contact

Microswitch

One set point or


(1 -SP.D.T)

Two set pOints


(2-S.P.D.T)

Electrical
rating

AC250V 3A (Non inductive)


AC 125V 5A (Non inductive)
DC 1?5V O.4A (Non inductive)

(2) Scale range


Range
-30~

Min. Scale

70"C

Range
150"C

2"C

O~

O~

50"C

l"C

0~200"C

2"C

* Range in deg. F

O~

1OO"C

2"C

0~300'C

5'C

is also available

--

* Other ranges in -

200

(3) Capillary

3m (Std),

(4) Thermobulb
ThrC'ad
PT '/2 (Std)

* Slidin~1 union type only

- 600 deg C is also available as specials.

10m (Single capillary) Max.,

50m (Double capillary) Max.

===ss=-
I

Material

L .,

S4SUS304 (Standard)
S6SUS316 (Available upon request)

Outside diameter:

(b) OrderinC]

Min. Scale
2'(

Bmm.

10mm,

12mm

(6m/m as a special order)

Please specify the following items.


Items

Example

I---

Description
--+----

Model

TE03-ME-S

Single capillary with one set point

Range

0~1

Scale range of

OO"C

O~

100 deg. C

I-

Capillary

3m

Capillary length of 3m (Standard)

Bulb dia

<p10

Thermobulb diameter of <p 10 (1 Omm)

Style of thermowell

Yes

If not required, please specify so.

Size of thermowell
--
Material of thermaell

1B JIS 10KRF

Standard inner thread 1/2" PT

<p 15 x 200

Out. dia. 1Omm Length 200mm

Rating

S4

S4=SUS304

AC1 OOV 3A
-

S6=SUS316

I Please specify your needs

Please contact us for further assistance for ordering.


16

."\.

;',".

MODEL SUO-M 1RU-S

MODEL TOS-M 1UU-S

Unit Type
Adaptive to installation condition, more thJn several standard model numbers are available, please select
the proper one by capillary's outlet, terminal box's and cable ground locations.

..
..
..
..
..
..
..
~

17

Description
Ambient Temp
Compensation
Conduit
Location

CIN

In truction

Single Capillary

Double Capillary

Underneath

Left hand side

Right hand side

Top

Underneath

L
R

Left hand side


---Right hand side

1 Set Point

2 Set Points

Switch Type

Microswitch

Mounting
Method

Without Mounting Flange

Surface Mounting

Capillary or
Stem Oullet
Location

Top

Underneath

Backside (Rigid stem only)

Indicating
Method

Remote Reading

Rigid Stem

Terminal Box
Location

No. of Switch

- --

Please note that slinding union-type bulbs have no effect against pressure. If you put the bulb on pressu
rized vessel, a thermowell will be needed.

Mdx. slilll~ pressure O. 'iMPil

(1) Fixed Screw Type

(4) Fixed Union Capillary Type


Max. stalic presswe O.!JMPa

L8tjU
-E
~(?) With thermowell type

(5) Sliding Union Type for remote reading only

Max. ,lalie pre"lIre 1Mf'a


f'led~(>

reler 10 paye 20
IllUiMOWELL

~---I(3) Plain Bulb Type

(6) Sliding Union type for rigid stem type only

VOLUME of the Thermobulb compared to mercury filled type.


Out dia 8 rjJ

NEss
-

O~

50'C

140mm

0--100'C

70

150"C

45

0-200C

40

0~300C

25

O~

Out dia 10 ep

NEss

Out dia 12 ep

NEss

:t ~:; Fm

MF

404
202
135

MF

MF

':~

25

63

20

45

20

60

15

50

MF: Mercury filled conventionill type

Standard Out Uia Size of Thermobulb.

) oplion

Liquid filled

Single Capillary

8 10 12 14 rP

Double Capillary (8)

101214rP

'
i
R=

eQx

=0.8

.
,,
I

. flange
o~

50'C

0~100

0~200

0~3:"0

"0~400

Gg=~gg

10

12

( 16)

75

50

30

70'

40

140

I 40
I

25

30

20

20

15

25

_ _ _ _ _-----'~.200~50 1455

15

20 115
195 120

235

150

110

12

1J

14

not available

Minimum Size of Thermobulb.


The Volume of the Thermobulb clepends on the Scale Range
mm
Single Capillary Type (- S)
r1x

Gas filled

10

80

mm

Double Capillary Type (-D)


Ranqe

0111

fi,a

10

O~ 50"C

O~

100
0-200

0~350

_I
80
4:"

12

180

j 115

90

60

45
30

35
25 I

14

16

80

60

45! _35_

_ _t_J.....--'L

Please add 25mm or more in Cilse of plain bulb Iype


"Gas Filled

18

Pipe(P) .. - - - - - - - - - - Straight Type (S) - Straight Type (S) - Screw (S) - [

Straight Type (S) - Drilled Bar Stock(D)

Taper Type (T)


Taper Type (T)

PiPe(p) - - - - - - - - - - - S t r a i g h t Type(S)-Flange(F) - {

~,.-----;[
Drilled Bar Stock(D) [

Straight Type (S) - Taper Type(T)

- [ Straight 1 ype (S) - Taper Type (T)

Weld-in (W)

19

- - - - - - - - - - - - - 1[

Straight Type (S) - Taper Type (T)

1A

2
2B
3A
3B
4
5

6
7
8
9

10

< Indicator>
.---_1_.-,-Model No.
2. Compensator

S=Single Capillary Type


3. Dial size

2- 1> 50

3- 1> 75

D=Double Capillary Typ<, (10m or more)

4= 1> 100

4. Scale range

6= 1> 150

6. Connection size

1 - 2 - 3 - 4 - 5. Thermowell O=Without - 6 - 7

7. Rating
JIS. ANSI, etc.

l~_~_~--~

10

W=With

11

1~

13

_ _J

8. Type of thermowell

9. Inner thread

10 Materials

1=304SS,

2=316SS,

3=316LSS,

X=others

1 1. Thermobulb model
A=Sliding Union Type, R=Fixed Union Type, S=Plain Bulb
X=olhers

<Contact>
12 Thermobulb malerial
1=304SS, 2=316SS, X=olhers
13. Malerial of flexible tube
F=304SS, V=Flexible lube PVC covered

14. Volta e

I '5"1 '6

~ - -l~ -

}-

Ope,ation mode

t -18 T'1~1-

22

]-~

I - l~Capillar

len th

~mobUlb~nglh

17.CO~

- - 1=15A(PF1 12)
4=20A(PF3/4)
X=olhers

-[23

22. O.Dof Thermobulb


21. 1.0.01 Thermowell

20. 00.01 Thermowell(D?)


19. 00. f Thermowell(Dl)

18. Option

20

For eliminating the missing specification or


mis-understanding for Ihe technical confirma
tion, the complele specificalion is a vital one.
Please copy the specification sheet on p e
22 and fill out. It will be a big help to InanufJc
ture the requested products accUiately and
swiftly.

t , - . . . "

Please enter dale prepared, your company and section names, as well as Tele
phone No., Order No. and File No.
Instrument Location nrtme if necessary to express on the instrument. If
not. leave It blank.

2.

Specify Tag

o. if it is required. If not, leave it blank.

3.

Select and mark Tag No. indlcatin<J localion. If not. leave it blank.

4.

Setect and mark Tag No. indicating method. If not, leave it blitnk.

5.

Select and mark the ambient teilipelature compensation method

Refer the CAT. and indicate Model

7.

Indicate nominal dial size. Ex) Dia

8.

Select and mark case color: Std. is Munsell N1. 2 (black)

9.

Select and mark scale plate color: Std. is white letter on black.

10.

Select and indicille scale range;


Ex) 0 l00"C or 32 -210'F

11.

Select and mark scale division;


please refer the CAT. for standard spec.
j

1---.1-

specify material names for capillary and flexible armor


not speCified.

Leave it blank. it

18
19

Mark the thermobulb style .


ark when Well IS reqUired. If not, leave it blan .
When Well IS reqUired, specify the Morlel No. by the table on rage 19.

When Well is not required, leave it blank.

17.

Specify the material when Well is required. Leave it illrlllk, if not re


qUlred.

18.

Indicate tank mnlerial for thermobulb. If not. leave il blank .

. 9.

SpeCify thread of flange sile lor thermobulb. In case 01 wi h well. speci


fy Installation dim nsions of well.

20.

Specify proof pressure for lhermoillllil. No need to specify In case of


standard spec.

21.

SpeCify vanous dimensions of thermobllib.

- - -

13.

6.

5 17

100mm

Enter capillary length (in unit of meier)

. 4.

~-17

12

15.

-0

CAT.
fJAGE ;

DESCRIPTION

ITEM
NO.

--

22.

23.

24.

25
26.

27.
28.
NOTE:

A) In case Ihe entry is same as left side column, may use


Bl AbbreViations for material are as follows:
SUS O~
S~
5U53 6
Others

21

56

., mark.

: 11.
",

Company Name:

----

I-

Dale prepared

Person 10 conlact:

No

No.

File No.'
No.
I

Location

lAG No

ame

--I-=- -
. L
0 I Selle
TAG Nu Indleatlng
ocatlon
Case

Tag No. Indicaling Method

-----1

I Adhe.

----

, Ca,e

Scale
-, Case

M~.

JA~a

Glass

,. S S. plate

SSplale

..J Single

Temp. Compensatron Method

~-

1S(~le

Glass

Lead
I Double Lead.:...,,

_ Sln~le Lead
Double Leaas

-S
_

- S

GI~ss

Scale
ICa_,_e

S S. plate

I I Glass
_

Adhe
S. S pl_al_e

I
I

_ S,nqle Lead
Double :::Le::a=ds=-

-_O

LJ SI/.gle Lead
I I Double Leads

-S
-D

-S
-0
-

Model No.

-r

Dial Size

Case color

Std .. Bldlk
CMunsell

o Wht.

Scale Color

10

Scale Range

II

Mlo. Division on SCdie

12

Capillary Lenglh

13

Capillary Mat'I
Flex. Armur Mat'I

'4

Thermobulb Model

,5

Well MIg, Method


Well Model

17

Well Mal'l

18

Thermohllih Mat'I

19

Thd, r1ange Dim.

.-J Whl

[J Wht. Ilr. on Blk.

Blk.
I [Jlk. Llr on Wht.

L 'C

LF

[ J Std

Std

Fixed I Sliding U Olhers I I Fixed


I Sliding
] Others ~ Fixed
Plain
I Flexible
+,::L=-l.:...p::la.:...ln.:... I Flexible
J Plain
Welding I I Special boring
0 Welding
Special bering
cJ Welding
BOling
[J Other
I Boring l ()I_he_r
...:=-:::: Boring

C Fixed

Slidlog [ ] Others
Flexible

L
I

, Welding

SpeCIal horing
OIlier

I D.

dl

oD

Ly

L:

IL9'

0.0. 02

02:

a;
~

I.D.

ell

Lg

I 0

d'

0.0 d

Well Inner Tllread

No. 01 set polnls

25

Ratlnq

26

Operatioo Mode

27

Remarks

28

Qly

I Iln'1. Set
"lExt1. Sel

11

set pOint
;] 2 sPt [lOlnls

- r~!lC

I DC

vol Is
volts

[lrl1. Sct
[IExt
Sel
-
r 'sel point
~? sel [lOlnt,

AC
....J DC

valls
volts

.CJ

-s
co
Lg

00 02

::J~t

L:

0.0, d:

~~

__

1.0. d l

Thermohllih Dim.

Lq

I:

~'Set

'Ext't. Set

I sci pOIf.t
2 set pUIf'!>

vailS
volls

D DI

00 01'

00 01:

24

1 Otller

Sci pOint Adjustment

Others

C SpeCial boring

1Boring

-I

------il

f-
23

0.0.

2?

J Sliding

::J FleXible

[ 1Plain

Thermobulb Proal-Press

?I

Std.

-~

U"C
I "F
~

-t-

20

~ht:LUn

I ] lJlk. L11. 00 Wht.

IF

cJ

::J Munsell

JC

J Std.

_______+C::=
1

'6

[ Std .. Black
CMunsell

UC
I IF

I I Sid. [Jlack

S d . Black
--' Munsell

tlr on Blk.
Blk Llr on Wht

I tr. 00 Blk.
_ _ _-t-=I-=J_lJlk. Llr on Whl

Nom. Size

am Size

Nom Size

Nom. Si7e

Ext'1. Sct

SCi POIOt

2 :,el poiots

--

11 AC

r I DC

volts
valls

Oil Refinery Plant


Pump [Illel
Oullel
Oil Cooler [nlel
(Jutlet
Compressor Air Outlet
Air Tn let
Boiler Slclm Temp
Helvy Oil Temp

Oil rig Plant


Gas Plant
Heavy Oil Temp
C.ooling Wltcr Temp
Gas Temp

Electric Power Plant


Nuclear Power Plant
Pump Tnlet
Outlet
Lvaporator Inlet
OUll..:t
Heater
Inkl
Outlet
Pur,' Water
Drain WaleI'
High Pressure Water
Turbin Oil
Thrust Metal Temp
Bearing Luhricant Oil
Stelm Supply
Return
Control OJ I
Air Ejeclor WaleI'
Hoi IeI' Feed Water
Oil Cookr Supply
Cooling Water
Air Cooler WaleI'
Turbin Outlet Steam
Exhlust Stelm Temp
Gland Seal Steam
Condensation Tank
Condensatiun Pump

LPG Plant
LNG Plant
Diesel Engin
Oil Temp
fuel Uil Temp
Cooling Water Temp
Exh;\lIst Gas Temp

Turbin Bearing
Coupling Side
Shafl Fne!
Gear Rox
Dearing Temp

Pump
Casing
Coupling:
Stuffing Box Gland
(icar Box
Bearing Temp

Submarine
Sea WaleI' Temp
Heavy Oil Temp
PUle Air Temp

Ship Build CO.,


Oil Serviee Tank
Oil Set Tank
Blend Oil Inkt
Fuel Oil Purifier Inlet
Lubricant Oil Purifier
Exhaust (ias Temp
Pinion Shan Rearing Ternp
Diesel Air Temp
Bear Shaft Bearing Temp
Oil Reservoir Oil remp
Acellmllialer
Sea Oil Temp
L P(i Tank

Chemical Plant
Fertilizer Plant
Food Plant
Sugar Plant
Milk Plant
Oil Tank
Powder Tank
Cement Plant
Ice Freezer
Milk Evaporator
Condensor
Baking Powder Mixer
Chocolate Mixer
Beer Plant
Soap Plant
Mayonaise Plant
Film Plant
Rayon Plant
Tire Plant
Injection Machine
Pulp Plant
Paper Plant
Water Plant
Desalination Plant
Shaft Temp of Heavy Machinery
Bearing Temp of Motor
Air Conditioning Plant
WaleI' supply
return
Air supply
rcl urn

Steel Company
Shaft Temp of Mill
l.uhricanL Oil Temp

All information and specifications in this catalog are current at the tIme of printing' (h:Jnql'"

in product design and specifications may occur without notice. Contact your area fddUlY

representative or the factory for the current revision of this catalog.

Our local representative is

OJ. 04. 1.000

Вам также может понравиться