1. INTRODUCTION
Post-tensioned concrete structures have been used extensively in the past decades in civil engineering structures
which are often intended to have design lives of 100 years. Tendon integrity is critical to the structures
continuing overall safety. The highly stressed steel is particularly susceptible to corrosion and each tendon
carries a high load. Hence, any damage during their service life may seriously affect the performance of the
structure.
Failures of tendons in structures in the USA and the UK have led to major improvements in post tensioned duct
grouting procedures overseas. In Australia grouting standards have not been upgraded to the same extent and
requirements are lower than those overseas. Grouting requirements in Australia remained at a level which led to
voidage in ducts overseas until recently so it may be that structures in Australia have voided ducts. The USA
and the UK use deicing salts on their roads and hence exposure of tendons in poorly grouted ducts may be more
severe and more concerning than in Australia. However, given the susceptibility of highly stressed tendon to
corrosion, our infrastructures close proximity to marine environments, and Australias grouting standards it is
inferred that the likelihood of failure of tendons would have to be possible according to AS 4360 (Table 1).
Risk is conventionally assessed (AS 4360) in two dimensions as shown in Table 1.
Table 1 : AS 4360 Risk Assessment
Consequence of Failure
Likelihood of failure
Negligible Low
Moderate Very High
Only in exceptional
Negligible Negligible Very Low
Low
Rare
circumstances
Could occur at some
Negligible Very Low
Low
Moderate
Unlikely
time
Might occur at some
Very Low
Low
Moderate
High
Possible
time
Probably occurs in
Low
Moderate
High
Extreme
Likely
most circumstances
Expected in most
Moderate
High
Extreme
Extreme
Almost Certain
circumstances
Extreme
Moderate
High
Extreme
Extreme
Extreme
Experience overseas has shown that if corrosion of tendons occurs, and goes unchecked, the consequence (e.g.
bridge collapse) could be extreme. Such extreme risk is unacceptable and needs to be reduced. In the case of
existing structures systematic inspection of structures to assess if tendon corrosion is occurring would reduce the
likelihood to rare. For new structures the likelihood can be reduced to rare by adopting US or UK grouting
standards.
Locating tendon may also be required during upgrading of post tensioned structures. Even as built drawings will
not locate the position of tendons accurately enough to ensure they are not cut during drilling and coring.
__________________________________________________________________________________________
1
Radar survey can effectively determine the position of tendon ducts in the post-tensioned concrete structure.
Thus the tendon ducts can be avoided during drilling or coring operations and located for Impact Echo testing to
investigate voids in tendon ducts. Radar and Impact Echo can be performed from one of the exposed face of the
structure, and they are truly non-destructive in nature. Coupled with intrusive fibrescope inspection detection of
and evaluation of voids in tendon ducts is possible.
2. DETECTION OF TENDONS USING RADAR
2.1 What is Radar (Impulse Radar, Ground Penetrating Radar)?
Radar, which stands for Radio Detection and Ranging, uses the reflection of microwaves to measure remote
objects. It is widely applied in many areas, i.e. military, air traffic control and car speed control by traffic police,
etc. In civil engineering applications, the radar devices emit short pulses of microwaves. For this reason, the
technique is often called short pulse radar or impulse radar. The method is most generally used for detecting
objects below ground (eg pipes) and the most common name has become Ground Penetration Radar (GPR).
2.2 Principle Of GPR For Tendon Detection
A very short pulse (few nanoseconds) is generated and input into the test object (ground or concrete) by a
transducer in contact with it. This transducer is referred to as an antenna. The microwave travels through the test
object and energy reflected back (back-scattered) by any embedded object that has a different properties,
specifically dielectric constant,, and the reflected waves are detected by a receiving antenna which is moving
along the surface together with the transmitting antenna. The received signal is processed and shown on a colour
monitor. A single pipe will appear as a hyperbola on the screen. This represents the reflected waves travel
distance reducing as the antennae approaches the object. Position and depth of the embedded object are obtained
just by reading coordinates of the hyperbolic shape within the radar image. The method is fully described in
American Concrete Institute Report ACI 228.2R-98, Nondestructive Test Methods for Evaluation of Concrete
in Structures.
One of the main applications in civil engineering is for tendon detection (more accurately, detecting tendon
ducts) in post-tensioned concrete structures. Equipment suitable for tendon detection is generally a control box
(with control unit, recorder and display units inside) and a high frequency (1000 MHz to 2000 MHz), antenna
The antenna is chosen to give the best balance between penetration depth and resolution for the testing being
undertaken.
It is possible to detect tendon ducts below reinforcement since tendon ducts have a larger diameter and present a
much bigger hyperbolic shape than rebars in the radar image.
2.3 Advantages And Limitations Of Radar In Tendon Detection
Radar can be performed from one face of the structure and it is truly non-destructive. Radar can differentiate
rebars and tendon ducts easily if they are embedded at a similar depth in the concrete, which is not possible for
conventional micro cover meter. Recently developed 3D imaging technique and multiple array antennas make
the tendons more visible even in some complicated arrangements.
Radar has some limitations .If the post-tensioned slab is thick and the tendon ducts are embedded deeply,
detection is difficult. The presence of additional topping on the slab with wire mesh can increase the difficulty
for tendon detection. Detection of tendons in beams mostly depends on the geometry of the beam and the
arrangement of rebars and tendons in the beam. If the tendons are embedded within the flange portion of Ibeam, inverted T-beam or U-beam tendon detection becomes more difficult. Some intrusive testing might be
required for verification. Skilled and experienced personnel are required for tendon detection. Some information
on the existing structure members can help the tendon detection 1.
3. INSPECTION OF GROUTING CONDITION OF TENDON DUCTS USING IMPACT ECHO TEST
3.1 Needs for inspection of grouting condition of tendon ducts
Generally, the tendons are protected by the surrounding grout, which is injected into the tendon ducts. Voids in
the grout can occur along the tendon trajectory due to blockages, improper grouting procedures, grouting
__________________________________________________________________________________________
2
material problems, and construction oversight. Inadequate grouting may allow water to penetrate into the ducts,
causing corrosion of the tendons leading to failure of the structures. Unfortunately, there may be little or no
visual evidence that something is wrong until it is too late. In UK, a post-tensioned bridge collapsed in the 1980s
as a result of corrosion of steel tendons 2.
Many researchers and testing engineers have been trying to explore some suitable technique to inspect grouting
conditions of tendon ducts in post-tensioned concrete structures for the past decades. The ideal test would, of
course, be one that could non-destructively determine the degree of corrosion and the remaining cross-sectional
area of each tendon along its full length. However, it does not currently exist and is unlikely to be developed in
the near future. For the time being, there are only limited techniques available for testing engineers to employ
for this application 2.
According to the authors opinion, a combination of Radar survey, Impact Echo, intrusive testing and fibrescope
inspection is the most suitable approach for inspection of grouting condition of tendon ducts for post-tensioned
concrete structures at this moment 3.
3.2 What is Impact Echo (IE)?
IE is a method for non-destructive evaluation of concrete based on stress waves propagation and reflection in the
concrete structure. ASTM Standard C 1383 - 98a describes the procedure of non-destructive measurement of the
thickness of plate like structures i.e. slab, wall using IE. However, it has been widely used to evaluate concrete
integrity and concrete repair of plate like structures. It can also be used to detect voids in tendon ducts in posttensioned slab and beam.
3.3 Principle of IE
A short-duration mechanical impact, produced by tapping a small steel sphere (or any other form of impact)
against a concrete surface, produces low-frequency stress waves that propagate into the structure and are
reflected by flaws and/or the opposite external surface. Surface displacement (or acceleration for certain impact
echo test systems) caused by these reflected waves are recorded by a transducer (or an accelerator), located
adjacent to the impact point. The resulting displacement (or acceleration) versus time signals are transformed
into the frequency domain, and plots of amplitude versus frequency (spectrums) are obtained. Carefully
examining the spectrums of amplitude vs. frequency collected at the test points along tendon duct at certain
interval can provide information on the grouting condition. Like Radar technique, IE is also fully described in
ACI 228.2R-98.
3.4 Advantages and limitations of IE
Although IE was developed in 1990s in USA, it has received significant acceptance in the world. IE has
become one of the best tools for concrete non-destructive evaluation for civil structures where access is
restricted to one face, often giving good and encouraging results. Comprehensive research has been done and a
guidebook IMPACT-ECHO: Nondestructive Evaluation of Concrete and Masonry (by Mary J. Sansalone,
and William B. Streett 1997) is available.
Occasionally, there are some conflicting reports regarding its applications and reliability. For detection of voids
in tendon duct, its applicability depends on the geometry of a structure and the locations and arrangement of
tendon ducts. Small voids in tendon ducts which are located too deep within a structure cannot be detected. In
some cases, complicated arrangement of multiple ducts, such as often occur in the flanges of concrete I-beams
or inverted T-beams, can preclude detection of voids in some or all of the ducts. It is very difficult to detect
voids in tendon ducts at the mid-span of I-beam and U-beam as the geometry at such a portion is too
complicated for IE.
The requirement for skilled personnel who can provide a reliable and thorough interpretation of IE test results
could have limited its wide application for this particular purpose.
__________________________________________________________________________________________
3
__________________________________________________________________________________________
4
Figure 1: a profile of typical tendon duct in an end span slab and impact echo test points
A preliminary inspection using fibrescope was conducted to inspect the presence of voids in the tendon ducts via
some of the existing grouting outlet hoses. The inspection confirmed the presences of full voids or partially
voids in a few tendon ducts. All these tendon ducts were selected for further detailed investigation. IE test was
then performed on the slab surface at an interval of 0.5m along these tendon ducts (refer to Figure 1). The
results of IE revealed that only one tendon duct had been badly grouted with significant void inside.
During construction stage, the questionable locations are generally known and limited to several locations.
Localised opening assisted with fibrescope inspection may be enough to solve the problems in a cheaper way.
5.2 Detection of tendons for coring for a new building 3
M&E works were in progress after the completion of structural works for a newly built commercial building.
Due to certain reason, the owner had decided to change usage of some units and had to add a washing room in
each unit. Some holes for installation of service pipes had to be drilled. The building was a seven-storey RC
structure. The most area of the floor slab was post-tensioned concrete slab with 250mm thickness and equally
spaced one way post-tensioning tendon ducts. There was a topping layer of 50mm thick chipping concrete with
75mm spaced wire mesh inside.
Radar survey was carried out to determine the positions of tendon ducts for coring work. A total of sixty four
core holes were drilled. All the works inclusive of tendon detection and coring work were finished within four
working days. The accuracy of the detection was optimistic. No tendon was hit during the coring work although
some coring holes were near to the detected tendons.
For this kind project where there is a layer of topping on the post-tensioned slab with wire mesh inside,
detection of tendons in the slab is not an easy task. Some handy type radar sets may not be able to locate tendons
at all the locations. Carefully selection of scan areas (preferably at the areas with shallower tendon depths), a
compromise between good resolution and deep penetrating depth, similar project experience of the personnel
seem to be decisive.
5.3 Investigation of voids in tendon duct of I-girder for an existing bridge 4
During an upgrading of a large bridge along an expressway, detection of voids in tendon ducts of I-girders was
required due to some signs of deterioration on the I-girder surfaces. The bridge consisted of 99 numbers of Igirders of each 30m length. Besides some prestressing strands in the bottom flange, there was a parabolic
profiled post-tensioned tendon duct in the web which was subjected to this investigation.
A combination of Radar, IE and fiberscope inspection was adopted. Radar survey was carried out to locate
centreline of tendon ducts. IE was used to determine voids in tendon ducts. It was mainly concentrated at the
two quarter lengths of the I-girder at two ends where the tendon duct was embedded within web portion. Figure
2 shows a cross sectional view of the I-girders.
__________________________________________________________________________________________
5
shifted domain
frequency
domain frequency
reflected by
tendon duct
reflected by tendons
in tendon duct
empty top
portion
tendons
grout at bottom
portion
__________________________________________________________________________________________
6
certain locations. Limited opening revealed that there were some empty tendon ducts. Thus, a full investigation
was followed up.
__________________________________________________________________________________________
7
6. CONCLUSIONS
If properly used, advanced NDT methods, such as Radar, IE and fibrescope, can often offer good solution to
meet the needs, and also provide a cost effective way for maintenance and upgrading of post-tensioned concrete
structures. However, skilled and experienced personnel with thorough understanding of these techniques are
required to get a proper test program and to interpret test data to obtain reliable results and findings.
Nevertheless, these advanced NDT methods have been successfully used in many countries worldwide.
ACKNOWLEDGEMENT
The author would like to thank SETSCO Services Pte Ltd (SETSCO) in Singapore. The reference papers by the
author listed below were published under SETSCOs name during which time the author worked with SETSCO.
REFERENCES
1) Yong Hao Zheng, Kee Ee Ng, John Wei Ong, Evaluation of concrete structures by advanced
nondestructive test methods impact echo test, impulse response test and radar survey, Proceedings,
International Symposium on Non-Destructive Testing in Civil Engineering (NDT-CE 2003), Berlin,
Germany. http://www.ndt.net/article/ndtce03/papers/v100/v100.htm
2) R. T. Stain and S Dixon, Identify the techniques currently available for inspecting the tendon condition in
post-tensioned bridges, Construction Repair Jan./Feb. 1994.
3) Yonghao Zheng, NDT methods for post-tensioned concrete structures, SETSCO Technology Forum
2005/ Concrete Technology Today, No. 3 Vol. 4 (2005), pages 22-23.
4) Honggang Cao, Yonghao Zheng, Detection of voids in tendon ducts of I-girders for an existing bridge,
Concrete Technology Today, No.2, Vol. 3 (2004), pages 24-29.
__________________________________________________________________________________________
8