Академический Документы
Профессиональный Документы
Культура Документы
www.caledonian-cables.co.uk
www.addison-cables.com
TABLE OF CONTENTS
TABLE OF CONTENTS
001
004
004
017
020
033
www.caledonian-cables.co.uk
071
075
Balise Cables
French KVB System
SPFB Speed Control System Cables 101
European ERTMS System
EUROBALISE SIF 102
EUROBALISE BGA 103
www.addison-cables.com
109
TABLE OF CONTENTS
137
164
www.caledonian-cables.co.uk
178
221
Ordering Information
233
www.addison-cables.com
What is ERTMS
The European Rail Trafc Management System has been dened in 3 levels
ERTMS Level 1:
www.caledonian-cables.co.uk
001
A. Eurobalises
- Overlay to Existing Signalling System.
- Movement Authorities through Eurobalise.
- Train Integrity & Position by Track Circuit.
002
www.addison-cables.com
Track Circuit
Eurobalises
Track Position
and Integrity
Eurobalises
www.caledonian-cables.co.uk
003
004
www.addison-cables.com
BASIC DESIGN
FOR RAILWAY CABLES
Caledonian designs a wide range of signalling and control (branded as RAILSIG), power (branded as
RAILFEEDER), coaxial (branded as RAILCOX), ber optic (branded as RAILOPTICS) and databus cables (branded as
RAILDATA) specially adapted to rail environments, providing enhanced re performance, oil resistance and exibility.
In rail sections including the station, trackside and tunnel, virtually all the cables have to be halogen free, as well as re
retardant, and assure low toxicity and minimal smoke to enhance survival, re ghting and emergency operations.
Caledonian covers wide area network for main line, metropolitan area network for subway, light rail and intercity
arrival/departures, and station range cable for efcient rail management. Caledonian can provides optic ber for both
analogue and digital railway applications such as (ESTMS/ETCS). Caledonian can also offer reliable cables to power the
trackside equipments and provide low frequency communications.
Copper multicore, multipair and multiquad are used for signalling and control cables. Caledonian signalling and
control cables guarantee electromagnetic immunity critical for communications from catenaries and current rail. They
are designed to survive along the track, resistant to high temperatures, humidity, oil and ultra violet light. They have
high dielectric strength, and come in low smoke halogen free and re retardant versions suitable for tunnels, stations
and platforms. The cables can be customized to provide different reduction factor, special re performance sheathing
and specic color coding. Caledonian signalling and control cables exhibits exceptional performance because of special
manufacturing process, choice of suitable insulation and sheathing materials for the rail environments.
Caledonian railway cables offer Rail authorities and operators, contractors a wide range of cable solutions, which may be
one of the world's most comprehensive and technologically advanced answers to rail industry.
Caledonian has developed railway cables that meet the challenges posed by railway industry for low smoke and
toxicity, even in a system that has the stringent requirement in the world. London Underground, a thriving railway system
that carries a billion passengers in a year, also lay claim to be the oldest train system in the world. The rst underground
railway to operate electric train, it is usually referred to as a tube, thanks to the shape of the tunnel far below the street
level. Built in late 1800s, the long tunnels were not designed for optimum re safety. In fact, the long sections are designed
without exits. As a result, if a re began inside the tunnels, smoke and fumes will overwhelm the passengers, who would have
no ready means of escape. Therefore, extreme precautions are taken to prevent the occurrences of re smoke, fume and toxic
vapor, which is one reason the system standard for smoke and toxicity is the most stringent of any rail systems in the world.
www.caledonian-cables.co.uk
005
rK
0.7
ZCO3
ZPAU
0.6
0.5
0.4
0.3
ZPAU
0.2
ZCO3
0.1
10
20
30
40
50
60
70
80 90 100
150
300
V1
(Volt/km)
ZPAU- Multipair Anti Induction Cables with two helically applied steel tapes (electromagnetic shield) and copper
tapes (electrostatic shield)
006
www.addison-cables.com
BASIC DESIGN
FOR RAILWAY CABLES
ZCO3- Multiquad Anti Induction Cables with two helically applied steel tapes (electromagnetic shield) and copper
tapes (electrostatic shield)
In a theoretical and simplied way, this factor is equal to |R/Z|, R being the linear D.C. resistance of the metallic
sheath and Z its linear impedance Z= r + jL at the frequency /2 (generally 50Hz). The minimum value of the rk factor
is obtained by decreasing R using screen with a high conductivity (such as copper) and by increasing L (and Z) choosing
a screen with a high magnetic permeability (such as steel).
Armoured Main Signalling Cables for non electrified lines or 1500V DC Lines (ZPFU Series)
The armoured ZPFU cables are used for the main circuits of 1500V DC electried lines.
Armoured Main Signalling Cables for 25KV AC electrified lines (ZPAU Series)
These cables are calledAnti Induction Cableswhich are recommended for use in the main circuits of electried
lines in 25KV A.C. They are designed with improved protection against induction according to the following principle:
when a telecommunication line is affected by electrical and magnetic elds resulting from the power supply voltage of the
catenaries (25KV A.C.), there is an electromotive force induced between conductors and earth. The anti induction cables
include several layers of metallic screens (copper and steel) to provide a very efcient protection against interferences.
Armoured Main Signalling Cables for High Speed Train lines (ZCO3 Series)
The basic application of ZCO3 cables is for the carrier current signal system of high speed train line (TGV). Due to
an increase in the induction screen thickness and the steel armor, their anti induction protection is much higher than the
ZPAU Series cables.
Equipment Cables for Control Centers (ZUG/SUG/ZUT, CV/CVZ & SCG Series)
ZUG/SUG/ZUT are equipment cables installed in trafc control centre or trackside equipment shelter, used for indoor
interconnection between the computer devices and railway network equipment. ZUG & ZUT are multipair equipment
cables and SUG are multicore equipment cables. CV/CVZ cables are used as cabling wires for the relays and electronic
equipment. The cables are suitable for use only in Optical Control Panel (OCP) wiring. The SCG cables are designed for
www.caledonian-cables.co.uk
007
connect the equipment centre to the device concerned. The cables are used as local control or power supply cables for
trackside and between the rail equipments.
K23 Cables
K23 are main armored LSZH multiquad signalling cables for metro local train and tramlines. They are designed
for remote controls and teletransmissions in underground railway networks. The cables are used for digicode cable
signalling, being laid in channel, cable tray, or on hook supports, along suburban railway lines, electried at maximum
1500V DC. The cables have aluminium moisture barrier, double steel tape armour and LSZH sheath.
K24 Cables
K24 are LSZH multipair signalling cables for metro local train and tramlines. They are designed for remote controls
and teletransmissions in underground railway networks. The cables are used for digicode cable signalling, being laid in
channel, cable tray, or on hook supports, along suburban railway lines, electried at maximum 1500V DC u, b. K24 have
aluminium moisture barrier and LSZH sheath, with optional double steel tape armouring,
Digicode Cable
Digicode Cable are indoor railway signalling cables designed for transmission of track circuit digicode signals up
to 30KHz in electried lines, being installed in cable trays. The cables are covered by ame retardant LSZH sheath with
double layers of steel tapes, with low capacitance values.
A-2Y2YB2Y/A-2Y2Yv
The A-2Y2YB2Y and A-2Y2Yv cables are multicore signalling cables designed for transmission of service tensions
for DC electried lines without induction protection. These cables can be offered with different capacitance values (115,
145 & 95nF/km). A-2Y2YB2Y cables are offered with one helically applied steel tape (0.2-0.3mm) or two helically applied
steel tapes (0.1mm). A-2Y2Yv cables are unarmoured version.
AJ-2Y(L)2YDB2Y
AJ-2Y(L)2YDB2Y are multipair signalling cables designed for AC electried lines with induction protection, suitable
for transmission of signals up to 90KHz in railway networks. With the combination of copper wires and either 0.5mm
or 0.8mm thick steel tape, the cables can be offered with different reduction factors (0.15, 0.35 and 0.55) and low
capacitance values of 45nF/km.
008
www.addison-cables.com
BASIC DESIGN
FOR RAILWAY CABLES
A-2Y(L)2YB2Y/A-2Y(L)2Yv
A-2Y(L)2YB2Y & A-2Y(L)2Yv are multipair signalling cables designed for DC electried lines without induction protection.
These cables can be offered with low capacitance values of 45nF/km. A-2Y(L)2YB2Y are offered with one helically applied
steel tape (0.2-0.3mm) or two helically applied steel tapes (0.1mm). A-2Y(L)2Yv cables are unarmoured version.
www.caledonian-cables.co.uk
009
Eurobalise Cables
Purpose of the Eurobalise is to transmit a message to the On-Board equipment in order to advise the driver and the
On-Board ATP processing unit about the train positioning and the conditions of the track and trafc ahead, and hence
take the appropriate actions for train speed and for the protection of the train itself, passengers and infrastructure alike.
010
www.addison-cables.com
BASIC DESIGN
FOR RAILWAY CABLES
The balise cables are used for the Eurobalise and the balise transmission
modules in the On-Board equipment. The cables are flexible, resistant and
have electromagnetic immunity for high frequency communications which is a
necessity for a radio based GSM-R trafc management system.
These specialised balise cables are to be used in the upgrading of
rail network to meet ERTMS (European Rail Traffic Management System)
requirements. The implementation of ERTMS will facilitate higher-speed services
and an increased number of connections on railways. The balise cables are advanced copper signalling cables which will be
installed along the tracks to carry vital information regarding train position, length and number of wagons. This information will
be used by the Automatic Train Control (ATC) system and relayed both to the driver via transponders, otherwise known as
"balises", and to the train control centre. The balise cables therefore play a vital role in maintaining high levels of safety as the
volume of rail trafc increases.
www.caledonian-cables.co.uk
011
Scada/Pilot Cables
The Scada/Pilot Cable are jelly lled 0.9mm multipair telephone cables complying with BS 3573. These telecom
cables are suitable for modem based Supervisory Control and Data Acquisition systems (SCADA) operating in the
VF range 300 to 3000Hz. The SCADA system is radio-based and includes an integrated hardware/software system
that monitors and alarms on the power distribution, escalator status, elevator status, security intrusion, fare collection
intrusion, re alarm etc.
The applicable standard is NR/PS/ELP/27220 (formerly RT/E/PS/0034) for UK NETWORK RAIL.
Radiating Cables
The radiating cables are another form of coaxial cables to provide a tuned bi-directional desired leakage effect
between transmitter and receiver. The cables are often used in underground, tunnels where an antenna is impossible.
These exible perforated coaxial cables act like antenna in this conned environment. They are extremely important for
ESTMS/ETCS radio based system.
012
www.addison-cables.com
BASIC DESIGN
FOR RAILWAY CABLES
www.caledonian-cables.co.uk
013
CSP sheath. Positive trackfeeder cables commonly used include 1x1000mm (aluminium), 1x630mm (copper) and
1x500 mm(aluminium). Negative trackfeeder cables commonly used include 1x800mm (aluminium), 1x500mm (copper),
1x240mm (aluminium), 1x161mm (copper) & 1x150mm (aluminium). The applicable standard is NR/PS/ELP/21101. BS
6360 and BS 6899 for UK NETWORK RAIL and NF-F5525 for France RATP.
014
www.addison-cables.com
BASIC DESIGN
FOR RAILWAY CABLES
effectively to the areas most prone to the effects of snow and ice. The point heating cables consist of Class 5 exible
tinned copper conductors, EPR (Ethylene Polypropylene Rubber) insulation and a PCP (Polychloroprene) sheath. These
heavy duty cables offer protection from abrasion and mechanical impact whilst maintaining exibility to ease installation
and provide power and control in Points Heating systems. The applicable standard is NR/SP/ELP/40045 (formerly RT/E/
PS40045) and BS 7919
www.caledonian-cables.co.uk
015
016
www.addison-cables.com
Trackside
Tr
a ks de
e Equipment
Equipment
Balise Cables
Balise
Bal
a se
Rail
10
Cable Types
11
Switching
Sw
w tc ing Motor
Mo o r
Trackside Box
10
Trackside Box
13 14 15
16
17
www.caledonian-cables.co.uk
20
19
Loop Cables
MV Power Cables
Conduit Wires
DC Traction Cables
15
18
Radiating Cables
14
EME-SP-14-026 / SE260L /
SE774 / SE895 (UK Railway Standard)
www.caledonian-cables.co.uk
13
12
11
Trackside Channel
16 17 18 19 20
Relay Room
Maintenance Room
Network Center
Signal Cables
Cable Types
Axle
A
Ax
le Counter
Cou ter
12
Encoder
10
Equipment shelter
Clock Server
DNC Server
Network Maintenance Server
017
018
www.addison-cables.com
Databus Cables
Coaxial Cables
Scada/Pilot Cables
Cable Types
4
9
3
8
14
13
12
11
Loop Cables
Digicode Cables
MV Power Cables
DC Traction Cables
9
10
Conduit Wires
Control Room
Cable Types
10 11 12 13
1
5
Camera
EME-SP-14-026 / SE260L /
SE774 / SE895 (UK Railway Standard)
Cable Trays/Ducts/Hooks
www.caledonian-cables.co.uk
Coaxial Cables
Data Cables
Cable Types
Control Room
2
5
21:30
Conduit Wires
Control Cables
Telephone Cables
Cable Types
Platform
Station
Lighting
1
4
)LUH
83
'2:1
Fire Alarm
Ticket Kiosk
Help Points
5
6
Ticket Halls
www.caledonian-cables.co.uk
Railway Platform
PA Broadcast System
Information Display
019
020
www.addison-cables.com
Standards
SNCF CT 500
Construction
Conductors: Class 5 stranded tinned
Polymide Sheath
PVC Insulation
Electrical Characteristics at 20
CV/CVZ
Nominal Conductor Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Operating Voltage
mm
mm
/km
V
0.8
0.5
36.1
1.17
1.0
17.9
750
1.78
2.5
7.56
CV-S/CVZ-S
No of Strands/ Strand Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Operating Voltage
No/mm
mm
/km
V
16/0.2
0.5
40.1
32/0.2
1.0
20.0
50/0.25
2.5
8.21
84/0.3
6
3.39
750
021
Cable Code
RS/CV-075-Y-1G0.5
RS/CVZ-075-Y(4Y)-1G1
RS/CVZ-075-Y(4Y)- 1G2.5
Nominal Weight
kg/km
2.3
13.2
3.1
29.3
CV-S/CVZ-S Cables
Number of
Conductors
Cable Code
RS/CV-S-075-Y-1G0.5
RS/CVZ-S-075-Y(4Y)-1G0.5
RS/CVZ-S-075-Y(4Y)-1G1
RS/CVZ-S-075-Y(4Y)-1P1S
RS/CVZ-S-075-Y(4Y)- 1G2.5
RS/CVZ-S-075- Y(4Y)-1G6
2.3
6.8
7.6
2.5
2.5
13.5
28.2
3.4
29.3
4.6
60.1
450/750V
Abrasion
Retardant
022
Resistant to High
Temperature
e
Weather Resistant
Mineral Oil
Resistant
Rated voltage
www.addison-cables.com
Nominal Weight
kg/km
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Standards
SNCF CT 455
FRPVC/LSZH Sheath
Stranded Tinned Copper Conductor
Construction
PVC Insulation
Twisted Pair
Screen (optional): Tinned copper braid for electrostatic protection (only for ZUT type).
Sheath: Black FRPVC compound. LSZH option can be offered upon request.
Electrical Characteristics at 20
No of Strands/ Strand Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Operating Voltage
No/mm
mm
/km
V
12/0.2
0.38
52.5
450/750
32/0.2
1
20.1
450/750
Number of Pairs
RS/ZUG-075-YY-28P0.38S
28
RS/ZUG-075-YY-1P1S
Nominal Weight
kg/km
15.7
310
7.0
59
023
Cable Code
Number of Pairs
RS/ZUG-075-YY-3P1S
RS/ZUG-075-YY-6P1S
RS/ZUG-075-YY-12P1S
3
6
12
0.7
0.7
0.7
9.9
12.4
15.7
Nominal Weight
kg/km
108
184
335
SUG Cables
Cable Code
Number of
Conductors
RS/SUG-075-YY-3C1S
Nominal Weight
kg/km
73
ZUT Cables
Cable Code
Number of Pairs
RS/ZUT-075-YCY-2P1S
RS/ZUT-075-YCY-6P1S
RS/ZUT-075-YCY-12P1S
2
6
12
450/750V
Rated voltage
024
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
www.addison-cables.com
9.5
13.5
17.5
Nominal Weight
kg/km
122
276
445
Standards
SNCF CT 466
Construction
PVC Sheath
Cross-linked PE Insulation
insulation.
Sheath: PVC sheath, coloured black.
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Operating Voltage
mm
mm
/km
V
1.78
2.5
7.56
2.76
6
3.11
750
450/750V
Number of Cores
RS/SCG-075-2XY-2G2.5
RS/SCG-075-2XY-4G2.5
RS/SCG-075-2XY-6G2.5
RS/SCG-075-2XY-8G2.5
2
4
6
8
RS/SCG-075-2XY-2G6
RS/SCG-075-2XY-4G6
RS/SCG-075-2XY-6G6
RS/SCG-075-2XY-8G6
2
4
6
8
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Nominal Weight
kg/km
14
17
19.5
21
227
336
475
542
18
20.5
23.5
26
384
550
780
940
025
AJ-2Y2YDB2Y S(H115)/S(H145)/S(H95)
Applications
The cables are designed for transmission of service tensions up to 600 VDC /
420 Veff AC100Hz in railway signalling networks, and are suitable for installation in
ducts or laying directly into the ground.
Standards
Dlk 1.013.107y
Dlk 1.013.107y
Dlk 1.013.108y (for 1.4/1.8mm conductor H95 type)
Dlk 1.013.110y
PE Sheath
Construction
Conductors: Solid annealed copper, 0.9,
1.4 or 1.8 mm nominal diameter.
Insulation: Solid polyethylene.
Stranding: Single conductors are helically
stranded in concentric layers. Cables from 14
conductors on have two extra conductors of 0.5mm with perforated insulation (surveillance conductors).
Core Wrapping: Plastic tape(s) with overlapping.
Inner Sheath: Low density polyethylene.
Electrostatic Shield: One layer of helically applied copper wires (0.9, 1.2, 1.4 or 1.8mm).
Electromagnetic Shield: Two helically applied steel tapes (0.5 or 0.8mm thick, depending on required reduction
factor).
Outer Sheath: Low density polyethylene.
Type Codes
AJ-
2Y
2Y
inner PE sheath
2Y
outer PE sheath
signal cable
LG
layer stranding
H (n)
operating capacity
026
www.addison-cables.com
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC (1min)
Maximum Mutual Capacitance @800Hz (AC)
Dielectric Strength, conductor to conductor (DC voltage 1min)
Surveillance Conductors
Loop resistance, maximum
Insulation resistance
- dry cable core, minimum
- wet cable core, maximum
Nominal Reduction Factor @ 100 V/km, 16 2/3 Hz
rk 401 series
rk 501 series
rk 601 series
Operating Voltage AC/DC
Test Voltage@50 Hz 1 min
Core to Core
Core to Screen
mm
/km
M.km
nF/km
V
0.9
28.9
10000
115
3535
1.4
11.9
10000
145/95*
3535
1.8
7.2
10000
145/95*
3535
/km
190
190
190
M.km
K.km
1000
30
1000
30
1000
30
0.15
0.35
0.55
420/600
0.15
0.35
0.55
420/600
0.15
0.35
0.55
420/600
Veff
Veff
2500
2500
2500
2500
2500
2500
*The value95is only for cables with 1.4/1.8mm conductors according to Dlk 1.013.108y.
Number of
conductors
(n)
Outer
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
19.0
20.0
22.0
25.0
29.0
32.0
35.0
38.0
520
650
780
1010
1330
1740
2310
2520
19.0
20.0
22.0
25.0
29.0
32.0
35.0
38.0
600
740
890
1150
1480
1910
2530
2730
Multicore Signalling & Control Main Cables for Trackside German DB Railway Standard
027
Number of
conductors
(n)
Outer
028
www.addison-cables.com
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
21
23.5
27
31
35
41
46
49
670
940
1180
1650
2270
3110
3900
4670
21
23.5
26
31
35
42
46
49
780
1070
1320
1810
2460
3380
4190
5000
23
25.6
28
33
38
44
48
52
960
1260
1940
2450
3280
4290
5200
6060
23
27
30
36
41
48
54
58
850
1260
1620
2080
3310
4570
5950
6970
23
27
30
36
42
49
55
59
970
1410
1780
2520
3570
5950
6170
7380
25
29
32
38
44
51
57
61
1160
1700
2400
3350
3310
4900
7340
8650
Cable Code
Nominal Sheath
Thickness
mm
Inner
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
22.0
24.0
27.0
30.0
35.0
900
1010
1220
1520
2090
32.0
38.0
2150
2900
25.0
27.0
30.0
34.0
42.0
1130
1330
1620
2340
3020
37.0
44.0
2880
3950
600V DC/420V AC
Zero
EMI
Anti Induction
UV Resistant
Water Resistant
Rated Voltage
Laid In Ducts
Buried in Ciround
Zero Halogen
Multicore Signalling & Control Main Cables for Trackside German DB Railway Standard
029
A-2Y2YB2Y S(H115)/S(H145)/S(H95)
Applications
The cables are designed in railways signalling networks, and are suitable for
installation in ducts or laying directly into the ground.
Standards
Dlk 1.013.107y
Dlk 1.013.108y (for 1.4/1.8mm conductor H95 type)
Dlk 1.013.110y
PE Sheath
Extra Perforated Insulated Conductor
Construction
Inner PE Sheath
stranded in concentric layers. Cables from 14 conductors on have two extra conductors of 0.5mm with perforated
insulation (surveillance conductors).
Core Wrapping: Plastic tape(s) with overlapping.
Inner Sheath: Low density polyethylene.
Armouring: One layer of galvanized steel tape (0.2-0.3mm) or two layers of galvanized steel tapes (0.1mm).
Outer Sheath: Low density polyethylene.
Type Codes
A
outdoor cable
2Y
2Y
inner PE sheath
2Y
PE outer sheath
signal cable
LG
layer stranding
H(n)
operating capacity
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
030
mm
/km
www.addison-cables.com
0.9
28.9
1.4
11.9
1.8
7.2
M.km
nF/km
10000
115
10000
145/95*
10000
145/95*
3535
3535
3535
/km
190
190
190
M.km
K.km
V
1000
30
420/600
1000
30
420/600
1000
30
420/600
Veff
Veff
2500
2500
2500
2500
2500
2500
*The value95is only for cables with 1.4/1.8mm conductors according to Dlk 1.013.108y.
Cable Code
RS107y-2Y2YB2Y-2C0.9-S(H115)
RS107y-2Y2YB2Y-4C0.9-S(H115)
RS107y-2Y2YB2Y-7C0.9-S(H115)
RS107y-2Y2YB2Y-10C0.9-S(H115)
RS107y-2Y2YB2Y-14C0.9-S(H115)
RS107y-2Y2YB2Y-20C0.9-S(H115)
RS107y-2Y2YB2Y-24C0.9-S(H115)
RS107y-2Y2YB2Y-30C0.9-S(H115)
RS107y-2Y2YB2Y-40C0.9-S(H115)
RS107y-2Y2YB2Y-50C0.9-S(H115)
RS107y-2Y2YB2Y-60C0.9-S(H115)
RS107y-2Y2YB2Y-80C0.9-S(H115)
RS107y-2Y2YB2Y-100C0.9-S(H115)
RS107y-2Y2YB2Y-120C0.9-S(H115)
RS107y-2Y2YB2Y-140C0.9-S(H115)
Outer
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.3
1.3
1.3
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
12.0
13.0
14.0
15.5
16.0
17.0
19.0
19.0
20.0
22.0
23.0
25.0
28.0
29.0
31.0
120
140
170
220
260
320
370
410
500
590
680
840
1020
1180
1360
RS107y-2Y2YB2Y-4C1.4-S(H145)
RS107y-2Y2YB2Y-7C1.4-S(H145)
RS107y-2Y2YB2Y-10C1.4-S(H145)
RS107y-2Y2YB2Y-14C1.4-S(H145)
RS107y-2Y2YB2Y-20C1.4-S(H145)
RS107y-2Y2YB2Y-24C1.4-S(H145)
Number of
conductors
(n)
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
14.0
15.5
18.0
19.0
21.0
22.0
190
260
340
420
550
630
Multicore Signalling & Control Main Cables for Trackside German DB Railway Standard
031
Number of
conductors
(n)
Cable Code
RS107y-2Y2YB2Y-30C1.4-S(H145)
RS107y-2Y2YB2Y-40C1.4-S(H145)
RS107y-2Y2YB2Y-50C1.4-S(H145)
RS107y-2Y2YB2Y-60C1.4-S(H145)
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
23.0
25.0
28.0
30.0
750
940
1140
1320
15.5
17.0
20.0
21.0
24.0
26.0
27.0
30.0
250
350
470
600
800
910
1100
1400
30
1.3
1.2
40
1.3
1.2
50
1.3
1.3
60
1.3
1.3
1.8mm Conductor, 2.7mm Insulated Wire
4
1.3
1.2
7
1.3
1.2
10
1.3
1.2
14
1.3
1.2
20
1.3
1.2
24
1.3
1.2
30
1.3
1.2
40
1.3
1.2
RS107y-2Y2YB2Y-4C1.8-S(H145)
RS107y-2Y2YB2Y-7C1.8-S(H145)
RS107y-2Y2YB2Y-10C1.8-S(H145)
RS107y-2Y2YB2Y-14C1.8-S(H145)
RS107y-2Y2YB2Y-20C1.8-S(H145)
RS107y-2Y2YB2Y-24C1.8-S(H145)
RS107y-2Y2YB2Y-30C1.8-S(H145)
RS107y-2Y2YB2Y-40C1.8-S(H145)
Cable Code
RS108y-2Y2YB2Y-10C1.4-S(H95)
RS108y-2Y2YB2Y-14C1.4-S(H95)
RS108y-2Y2YB2Y-20C1.4-S(H95)
RS108y-2Y2YB2Y-10C1.8-S(H95)
RS108y-2Y2YB2Y-14C1.8-S(H95)
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
18.0
20.0
22.0
390
480
610
21.0
23.0
550
700
600V DC/420V AC
Zero
UV Resistant
032
Water Resistant
Rated Voltage
Laid In Ducts
Buried in Ciround
www.addison-cables.com
Zero Halogen
A-2Y2Yv S(H115)/S(H145)/S(H95)
Applications
The cables are designed for general uses in protective devises in railways
signalling networks, and are suitable for installation in ducts.
Standards
Dlk 1.013.107y
Dlk 1.013.108y (for 1.4/1.8mm conductor H95 type)
Dlk 1.013.110y
Construction
Solid PE Insulation
Non Hygroscopic Tape
Outer PE Sheath
Stranding: Single conductors are helically stranded in concentric layers. Cables from 14 conductors on, have two
extra conductors with perforated insulation (surveillance conductors).
Core Wrapping: Plastic tape(s) with overlapping.
Outer Sheath: Low density polyethylene.
Type Codes
A
outdoor cable
2Y
2Yv
signal cable
LG
layer stranding
H(n)
operating capacity
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC (1min)
Maximum Conductor Capacitance @800Hz (AC)
Dielectric Strength, conductor to conductor (DC voltage 1min)
Surveillance Conductors
Loop resistance, maximum
Insulation resistance
- dry cable core, minimum
mm
/km
M.km
nF/km
V
0.9
28.9
10000
115
3535
1.4
11.9
10000
145/95*
3535
1.8
7.2
10000
145/95*
3535
/km
190
190
190
M.km
1000
1000
1000
Multicore Signalling & Control Main Cables for Trackside German DB Railway Standard
033
K.km
V
30
420/600
30
420/600
30
420/600
Veff
Veff
2500
2500
2500
2500
2500
2500
*The value95is only for cables with 1.4/1.8mm conductors according to Dlk 1.013.108y.
Cable Code
Nominal Sheath
Thickness
mm
RS107y-2Y2Yv-2C0.9-S(H115)
RS107y-2Y2Yv-4C0.9-S(H115)
RS107y-2Y2Yv-7C0.9-S(H115)
RS107y-2Y2Yv-10C0.9-S(H115)
RS107y-2Y2Yv-14C0.9-S(H115)
RS107y-2Y2Yv-20C0.9-S(H115)
RS107y-2Y2Yv-24C0.9-S(H115)
RS107y-2Y2Yv-30C0.9-S(H115)
RS107y-2Y2Yv-40C0.9-S(H115)
RS107y-2Y2Yv-50C0.9-S(H115)
RS107y-2Y2Yv-60C0.9-S(H115)
RS107y-2Y2Yv-80C0.9-S(H115)
RS107y-2Y2Yv-100C0.9-S(H115)
RS107y-2Y2Yv-120C0.9-S(H115)
RS107y-2Y2Yv-140C0.9-S(H115)
RS107y-2Y2Yv-160C0.9-S(H115)
RS107y-2Y2Yv-180C0.9-S(H115)
RS107y-2Y2Yv-200C0.9-S(H115)
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
9.0
9.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
19.0
20.0
22.0
25.0
26.0
28.0
29.0
32.0
32.0
60
75
100
130
170
220
260
310
380
460
540
690
850
990
1150
1260
1460
1600
RS107y-2Y2Yv-4C1.4-S(H145)
RS107y-2Y2Yv-7C1.4-S(H145)
RS107y-2Y2Yv-10C1.4-S(H145)
RS107y-2Y2Yv-14C1.4-S(H145)
RS107y-2Y2Yv-20C1.4-S(H145)
RS107y-2Y2Yv-24C1.4-S(H145)
RS107y-2Y2Yv-30C1.4-S(H145)
RS107y-2Y2Yv-40C1.4-S(H145)
RS107y-2Y2Yv-50C1.4-S(H145)
RS107y-2Y2Yv-60C1.4-S(H145)
RS107y-2Y2Yv-80C1.4-S(H145)
RS107y-2Y2Yv-100C1.4-S(H145)
034
Number of
conductors
(n)
Nominal Sheath
Thickness
mm
www.addison-cables.com
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
11.0
12.0
15.0
16.0
17.0
19.0
20.0
22.0
24.0
26.0
29.0
33.0
120
180
240
320
430
500
600
770
950
1120
1450
1810
Nominal Sheath
Thickness
mm
Number of
conductors
(n)
Cable Code
RS107y-2Y2Yv-120C1.4-S(H145)
RS107y-2Y2Yv-140C1.4-S(H145)
RS107y-2Y2Yv-160C1.4-S(H145)
RS107y-2Y2Yv-180C1.4-S(H145)
RS107y-2Y2Yv-200C1.4-S(H145)
RS107y-2Y2Yv-4C1.8-S(H145)
RS107y-2Y2Yv-7C1.8-S(H145)
RS107y-2Y2Yv-10C1.8-S(H145)
RS107y-2Y2Yv-14C1.8-S(H145)
RS107y-2Y2Yv-20C1.8-S(H145)
RS107y-2Y2Yv-24C1.8-S(H145)
RS107y-2Y2Yv-30C1.8-S(H145)
RS107y-2Y2Yv-40C1.8-S(H145)
RS107y-2Y2Yv-50C1.8-S(H145)
RS107y-2Y2Yv-60C1.8-S(H145)
RS107y-2Y2Yv-80C1.8-S(H145)
RS107y-2Y2Yv-100C1.8-S(H145)
RS107y-2Y2Yv-120C1.8-S(H145)
RS107y-2Y2Yv-140C1.8-S(H145)
RS107y-2Y2Yv-160C1.8-S(H145)
RS107y-2Y2Yv-180C1.8-S(H145)
RS107y-2Y2Yv-200C1.8-S(H145)
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
35.0
37.0
39.0
42.0
43.0
2140
2470
2800
3140
3460
12.0
14.0
17.0
18.0
21.0
22.0
24.0
27.0
29.0
31.0
35.0
40.0
42.0
46.0
49.0
52.0
53.0
170
260
355
475
655
760
930
1210
1480
1760
2310
2860
3390
3930
4500
5100
5600
120
2.2
140
2.2
160
2.2
180
2.2
200
2.2
1.8mm Conductor, 2.7mm Insulated Wire
4
2.0
7
2.0
10
2.0
14
2.2
20
2.2
24
2.2
30
2.2
40
2.2
50
2.2
60
2.2
80
2.2
100
2.2
120
2.2
140
2.2
160
2.2
180
2.2
200
2.2
RS108y-2Y2Yv-10C1.4-S(H95)
RS108y-2Y2Yv-14C1.4-S(H95)
RS108y-2Y2Yv-20C1.4-S(H95)
RS108y-2Y2Yv-30C1.4-S(H95)
RS108y-2Y2Yv-50C1.4-S(H95)
RS108y-2Y2Yv-10C1.8-S(H95)
RS108y-2Y2Yv-14C1.8-S(H95)
RS108y-2Y2Yv-20C1.8-S(H95)
RS108y-2Y2Yv-30C1.8-S(H95)
RS108y-2Y2Yv-50C1.8-S(H95)
Number of
conductors
(n)
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
16.0
18.0
20.0
24.0
29.0
270
350
470
670
1050
19.0
21.0
24.0
28.0
36.0
400
540
730
1050
1700
600V DC/420V AC
Zero
UV Resistant
Water Resistant
Rated Voltage
Laid In Ducts
Zero Halogen
Multicore Signalling & Control Main Cables for Trackside German DB Railway Standard
035
Standards
NR/PS/SIG/00005(formerly RT/E/PS/00005)
Construction
C o r e Wr a p p i n g : P l a s t i c t a p e ( s ) w i t h
overlapping.
Sheath: LSZH (for types A2 & A3 only).
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor DC Resistance
Voltage Rating
Nominal Insulation Thickness
mm
/km
KV
mm
0.75
24.8
1.15
17.3
0.65/1.1
0.85
0.85
RS/A1-H-1G0.75(BL)
RS/A1-H-1G0.75(BR)
RS/A1-H-1G0.75(RD)
RS/A1-H-1G0.75(OR)
036
www.addison-cables.com
Overall Diameter
Min/Max
mm
Nominal
Weight
kg/km
2.7/3.2
2.7/3.2
2.7/3.2
2.7/3.2
16
16
16
16
Cable Code
RS/A1-H-1G0.75(GR)
RS/A1-H-1G0.75(VI)
RS/A1-H-1G0.75
RS/A1-H-1G1.15
1x0.75(green)
1x0.75(violet)
1x0.75(black)
1x1.15(black)
RS/A2-3GH-1G0.75
RS/A2-3GH-1G1.15
1x0.75
1x1.15
RS/A3-3GH-2G0.75
RS/A3-3GH-4G0.75
RS/A3-3GH-6G0.75
RS/A3-3GH-10G0.75
RS/A3-3GH-14G0.75
RS/A3-3GH-36G0.75
RS/A3-3GH-48G0.75
2x0.75
4x0.75
6x0.75
10x0.75
14x0.75
36x0.75
48x0.75
7/0.37
7/0.37
7/0.37
16/0.30
Type A2(with sheath)
7/0.37
16/0.30
Type A3(with sheath)
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
Overall Diameter
Min/Max
mm
Nominal
Weight
kg/km
2.7/3.2
2.7/3.2
2.7/3.2
2.9/3.6
16
16
16
21
0.7
0.7
4.0/5.0
4.3/5.3
30
35
0.9
1.0
1.1
1.2
1.3
1.6
1.6
6.7/8.8
8.0/10.4
9.7/12.5
12.6/16.1
13.8/17.7
21.6/26.9
24.3/30.7
67
108
160
259
495
752
963
650/1100V
e
Impact Resistant
Highly Flexible
Oil Resistant
Weather Resistant
Rated Voltage
Laid In Ducts
Low Corrosivity
Low Toxicity
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Multicore Signalling & Control Main Cables for Trackside UK NETWORK RAIL Standard
037
Standards
NR/PS/SIG/00005(formerly RT/E/PS/00005)
Construction
Stranded Tinned Copper Conductor
EPR Insulation
HDPCP Sheath
overlapping.
Sheath: HDPCP Type RS2 to BS 7655.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
Nominal Insulation Thickness
mm
/km
KV
mm
0.75
24.8
1.5
12.2
2.5
7.56
0.85
0.8
0.8
10.0
16.0
1.84
1.16
0.65/1.1
1.0
1.0
35.0
0.529
70.0
0.27
95.0
0.195
1.2
1.4
1.6
RS/B1-3G5G-1G0.75
RS/B1-3G5G-1G1.5
RS/B1-3G5G-1G2.5
038
www.addison-cables.com
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
2.0
2.0
2.0
6.5/8.1
6.8/8.5
7.2/8.9
28
31
34
Cable Code
RS/B1-3G5G-1G10
RS/B1-3G5G-1G35
RS/B2-3G5G-2G1.5
RS/B2-3G5G-2G2.5
RS/B2-3G5G-2G10
RS/B2-3G5G-2G16
RS/B2-3G5G-2G35
RS/B2-3G5G-2G70
RS/B2-3G5G-2G95
RS/B2-3G5G-4G0.75
RS/B2-3G5G-7G0.75
RS/B2-3G5G-10G0.75
RS/B2-3G5G-12G0.75
RS/B2-3G5G-19G0.75
RS/B2-3G5G-27G0.75
RS/B2-3G5G-37G0.75
RS/B2-3G5G-48G0.75
RS/B2-3G5G-4G1.5
RS/B2-3G5G-7G1.5
RS/B2-3G5G-10G1.5
RS/B2-3G5G-12G1.5
RS/B2-3G5G-19G1.5
RS/B2-3G5G-27G1.5
RS/B2-3G5G-37G1.5
RS/B2-3G5G-48G1.5
RS/B2-3G5G-4G2.5
RS/B2-3G5G-7G2.5
RS/B2-3G5G-10G2.5
RS/B2-3G5G-12G2.5
RS/B2-3G5G-19G2.5
RS/B2-3G5G-27G2.5
RS/B2-3G5G-37G2.5
RS/B2-3G5G-48G2.5
RS/B2-3G5G-6P0.75S
7/1.35
19/1.53
Type B2
7/0.53
7/0.67
7/1.35
7/1.70
19/1.53
19/2.14
19/2.52
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.37
21.5
22.5
210.0
216.0
235.0
270.0
295.0
40.75
70.75
100.75
120.75
190.75
270.75
370.75
480.75
41.5
71.5
101.5
121.5
191.5
271.5
371.5
481.5
42.5
72.5
102.5
122.5
192.5
272.5
372.5
482.5
620.75
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
2.0
2.0
9.4/11.8
12.9/16.1
205
495
2.0
2.0
2.0
2.0
2.2
2.4
2.6
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.4
2.0
2.0
2.0
2.0
2.0
2.2
2.4
2.6
2.0
9.4/12.1
10.5/13.1
15.0/18.7
16.7/20.9
22.3/27.8
28.8/36.0
33.2/41.5
10.2/12.8
11.8/14.7
14.4/18.0
14.8/18.5
17.0/21.3
20.1/25.1
22.7/28.4
25.7/32.2
10.9/13.7
12.6/15.8
15.6/19.4
16.0/20.0
18.5/23.1
22.2/27.8
25.1/31.4
28.1/35.1
11.9/14.8
13.8/17.2
17.1/21.3
17.6/22.0
20.4/25.5
24.6/30.7
27.8/34.7
31.2/39.0
19.7/24.6
135
170
443
625
1232
2053
2968
140
214
280
321
451
602
799
973
217
296
401
437
615
856
1126
1494
260
370
520
599
835
1232
1623
2032
372
650/1100V
e
Impact Resistant
Highly Flexible
Rated Voltage
Laid In Ducts
Multicore Signalling & Control Main Cables for Trackside UK NETWORK RAIL Standard
039
Standard
NR/PS/SIG/00005(formerly RT/E/PS/00005)
Construction
Stranded Tinned Copper Conductor
EPR Insulation
HDPCP Sheath
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
Nominal Insulation Thickness
mm
/km
KV
mm
2.5
8.21
0.65/1.1
1.05
Highly Flexible
Oil Resistant
650/1100V
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
50/0.25
3.8
11.2/14.0
195
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
3.8
3.8
3.8
3.8
3.8
3.8
14.9/18.8
16.4/20.9
18.7/23.7
22.5/28.6
23.2/29.3
25.3/32.0
370
460
610
920
950
1180
RS/C1-3G5G-1G2.5
12.5
RS/C2-3G5G-2G2.5
RS/C2-3G5G-4G2.5
RS/C2-3G5G-7G2.5
RS/C2-3G5G-10G2.5
RS/C2-3G5G-12G2.5
RS/C2-3G5G-16G2.5
22.5
42.5
72.5
102.5
122.5
162.5
Type C1
Type C2
040
Laid In Ducts
www.addison-cables.com
Standard
NR/PS/SIG/00005(formerly RT/E/PS/00005)
Construction
Aluminium Tape
EPR Insulation
Drain Wire
HDPCP Sheath
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Minimum Noise Reduction
Voltage Rating
Nominal Insulation Thickness
mm
/km
dB
KV
mm
2.5
8.21
60
0.65/1.1
1.05
Impact Resistant
Highly Flexible
Oil Resistant
650/1100V
RS/C3-3G(St)5G-1P2.5S
Laid In Ducts
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
3.8
15.0/20.0
390
Multicore Signalling & Control Main Cables for Trackside UK NETWORK RAIL Standard
041
Standards
NR/PS/SIG/00005(formerly RT/E/PS/00005)
Stranded Tinned Copper Conductor
Construction
LSZH/EPR Insulation
LSZH Sheath
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
Nominal Insulation Thickness
mm
/km
KV
mm
0.75
24.8
1.5
12.2
2.5
7.56
0.85
0.8
0.8
10.0
16.0
1.84
1.16
0.65/1.1
1.0
1.0
35.0
0.529
70.0
0.27
95.0
0.195
1.2
1.4
1.6
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
2.0
2.0
2.0
2.0
2.0
6.5/8.1
6.8/8.5
7.2/8.9
9.4/11.8
12.9/16.1
25
30
34
205
495
Type D1
RS/D1-3GH-1G0.75
RS/D1-3GH-1G1.5
RS/D1-3GH-1G2.5
RS/D1-3GH-1G10
RS/D1-3GH-1G35
042
10.75
11.5
12.5
110.0
135.0
7/0.37
7/0.53
7/0.67
7/1.35
19/1.53
www.addison-cables.com
Cable Code
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
2.0
2.0
2.0
2.0
2.2
2.4
2.6
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.4
2.0
2.0
2.0
2.0
2.0
2.2
2.4
2.6
9.4/12.1
10.5/13.1
15.0/18.7
16.7/20.9
22.3/27.8
28.8/36.0
33.2/41.5
10.2/12.8
11.8/14.7
14.4/18.0
14.8/18.5
17.0/21.3
20.1/25.1
22.7/28.4
25.7/32.2
10.9/13.7
12.6/15.8
15.6/19.4
16.0/20.0
18.5/23.1
22.2/27.8
25.1/31.4
28.1/35.1
11.9/14.8
13.8/17.2
17.1/21.3
17.6/22.0
20.4/25.5
24.6/30.7
27.8/34.7
31.2/39.0
140
170
383
625
994
2121
2760
150
225
280
321
425
606
786
972
250
370
410
410
615
897
1126
1280
340
500
680
613
815
1200
1600
1960
Type D2
RS/D2-3GH-2G1.5
RS/D2-3GH-2G2.5
RS/D2-3GH-2G10
RS/D2-3GH-2G16
RS/D2-3GH-2G35
RS/D2-3GH-2G70
RS/D2-3GH-2G95
RS/D2-3GH-4G0.75
RS/D2-3GH-7G0.75
RS/D2-3GH-10G0.75
RS/D2-3GH-12G0.75
RS/D2-3GH-19G0.75
RS/D2-3GH-27G0.75
RS/D2-3GH-37G0.75
RS/D2-3GH-48G0.75
RS/D2-3GH-4G1.5
RS/D2-3GH-7G1.5
RS/D2-3GH-10G1.5
RS/D2-3GH-12G1.5
RS/D2-3GH-19G1.5
RS/D2-3GH-27G1.5
RS/D2-3GH-37G1.5
RS/D2-3GH-48G1.5
RS/D2-3GH-4G2.5
RS/D2-3GH-7G2.5
RS/D2-3GH-10G2.5
RS/D2-3GH-12G2.5
RS/D2-3GH-19G2.5
RS/D2-3GH-27G2.5
RS/D2-3GH-37G2.5
RS/D2-3GH-48G2.5
21.5
22.5
210.0
216.0
235.0
270.0
295.0
40.75
70.75
100.75
120.75
190.75
270.75
370.75
480.75
41.5
71.5
101.5
121.5
191.5
271.5
371.5
481.5
42.5
72.5
102.5
122.5
192.5
272.5
372.5
482.5
7/0.53
7/0.67
7/1.35
7/1.70
19/1.53
19/2.14
19/2.52
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
650/1100V
e
Impact Resistant
Highly Flexible
Oil Resistant
Weather Resistant
Rated Voltage
Laid In Ducts
Low Corrosivity
Low Toxicity
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Multicore Signalling & Control Main Cables for Trackside UK NETWORK RAIL Standard
043
Standards
NR/PS/SIG/00005(formerly RT/E/PS/00005)
Construction
Conductors: Tinned stranded copper, class 5
LSZH/EPR Insulation
LSZH Sheath
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
2.5
/km
8.21
Voltage Rating
KV
0.65/1.1
mm
1.05
Nominal Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
3.8
11.2/14.0
200
Type E1
RS/E1-3GH-1G2.5
12.5
50/0.25
Type E2
RS/E2-3GH-2G2.5
22.5
50/0.25
3.8
14.9/18.8
380
RS/E2-3GH-4G2.5
42.5
50/0.25
3.8
16.4/20.9
470
RS/E2-3GH-7G2.5
72.5
50/0.25
3.8
18.7/23.7
625
RS/E2-3GH-10G2.5
102.5
50/0.25
3.8
22.5/28.6
940
044
www.addison-cables.com
Cable Code
Nominal Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
RS/E2-3GH-12G2.5
122.5
50/0.25
3.8
23.2/29.3
980
RS/E2-3GH-16G2.5
162.5
50/0.25
3.8
25.3/32.0
1200
RS/E2-3GH-1P2.5S
122.5
50/0.25
3.8
15.0/20.0
341
650/1100V
e
Impact Resistant
Highly Flexible
Oil Resistant
Weather Resistant
Rated Voltage
Laid In Ducts
Low Corrosivity
Low Toxicity
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Multicore Signalling & Control Main Cables for Trackside UK NETWORK RAIL Standard
045
Standards
NR/PS/SIG/00005(formerly RT/E/PS/00005)
Construction
Aluminium Tape
LSZH/EPR Insulation
Drain Wire
7655.
LSZH Sheath
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
2.5
/km
8.21
dB
60
Voltage Rating
KV
0.65/1.1
mm
1.05
046
www.addison-cables.com
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
3.8
15.0/20.0
410
Type E3
RS/E3-3G(St)H-1P2.5S
1 x 2 x 2.5
50/0.25
650/1100V
e
Impact Resistant
Highly Flexible
Oil Resistant
Weather Resistant
Rated Voltage
Laid In Ducts
Low Corrosivity
Low Toxicity
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Multicore Signalling & Control Main Cables for Trackside UK NETWORK RAIL Standard
047
EAPSP n11.4
Applications
The cables are used as railway cables and can be installed directly into the
ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Construction
Outer PE Sheath
Solid PE Insulation
Solid Copper Conductor
concentric layers.
Core Wrapping: Plastic tape(s) with
overlapping.
Moisture Barrier: One laminated sheath made of aluminium tape (0.2mm thick) coated with copolymer on at least
one side is applied longitudinally with overlap.
Inner Sheath: PE sheath.
Armour: One corrugated steel tape is longitudinally applied with overlap.
Outer Sheath: PE sheath.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Resistance Unbalance
Test Voltage @50Hz 1min
Core to Core
Core to Screen
Core to Armouring
mm
/km
M.km
%
1.4
11.7
25000
2
Veff
Veff
Veff
2100
2500
2000
048
www.addison-cables.com
Cable Code
Outer
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
15.7
17.1
19.9
20.0
22.0
24.8
26.9
29.7
31.8
270
350
420
480
630
810
1010
1240
1490
RS/EAPSP-2Y(L)2Y(SR)2Y-4C1.4
RS/EAPSP-2Y(L)2Y(SR)2Y-7C1.4
RS/EAPSP-2Y(L)2Y(SR)2Y-9C1.4
RS/EAPSP-2Y(L)2Y(SR)2Y-12C1.4
RS/EAPSP-2Y(L)2Y(SR)2Y-19C1.4
RS/EAPSP-2Y(L)2Y(SR)2Y-27C1.4
RS/EAPSP-2Y(L)2Y(SR)2Y-37C1.4
RS/EAPSP-2Y(L)2Y(SR)2Y-48C1.4
RS/EAPSP-2Y(L)2Y(SR)2Y-61C1.4
300/500V
Zero
UV Resistant
Water Resistant
Laid In Ducts
Zero Halogen
Multicore Signalling & Control Main Cables for Trackside Spain RENFE Railway Standard
049
CCPSSP-FR0.3 n11.4
Applications
The cables are used as railway cables and can be installed directly into the
ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Construction
Outer PE Sheath
Solid PE Insulation
Solid Copper Conductor
Insulation: PE insulation.
Inner PE Sheath
Double Steel Tapes
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Resistance Unbalance
Test Voltage @50Hz 1min
Core to Core
Core to Screen
Reduction Factor @100V/km 50Hz
mm
/km
M.km
%
1.4
11.9
15000
2
Veff
Veff
2100
2500
0.3
050
www.addison-cables.com
Cable Code
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-2C1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-4C1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-7C1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-9C1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-12C1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-19C1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-27C1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-37C1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-48C1.4
1.6
1.6
1.6
1.6
1.6
1.8
1.8
1.8
1.8
16.5
17.5
19.0
22.7
23.2
25.2
28.1
31.4
34.2
Nominal
Weight
kg/km
530
608
718
914
977
1185
1437
1754
2062
300/500V
Zero
EMI
UV Resistant
Water Resistant
Laid In Ducts
Zero Halogen
Anti Induction
Multicore Signalling & Control Main Cables for Trackside Spain RENFE Railway Standard
051
CCTSST-FR0.3 n11.4
Applications
The cables are used as railway cables and can be installed directly into the
ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Construction
Insulation: PE insulation.
Stranding: Cores are helically stranded in concentric
layers.
Core Wrapping: Two or more layers of plastic tape(s) with overlapping.
Screen: Copper tapes with overlap (protection against interference).
Inner Sheath: FRNC-PE sheath, coloured green.
Armour: Two layers of steel tape (0.8mm thick).
Outer Sheath: FRNC-PE sheath, coloured green.
*FRNC: Flame retardant, non corrosive.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Resistance Unbalance
Test Voltage @50Hz 1min
Core to Core
Core to Screen
Reduction Factor @100V/km 50Hz
mm
/km
M.km
%
1.4
11.7
35000
2
Veff
Veff
2100
2500
0.3
052
www.addison-cables.com
Cable Code
RS/CCTSST-FR0.3-2Y(K)HBH-4C1.4
RS/CCTSST-FR0.3-2Y(K)HBH-19C1.4
RS/CCTSST-FR0.3-2Y(K)HBH-27C1.4
RS/CCTSST-FR0.3-2Y(K)HBH-48C1.4
Outer
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
18.0
26.1
29.2
36.7
705
1362
1648
2348
300/500V
EMI
Anti Induction
UV Resistant
Water Resistant
Rated Voltage
Buried in Ciround
Laid In Ducts
Low Corrosivity
Low Toxicity
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Multicore Signalling & Control Main Cables for Trackside Spain RENFE Railway Standard
053
AJ-2Y(L)2YDB2Y S(H45)
Applications
The cables are designed for transmission of low frequent signals up to 90
KHz through symmetric circuits in railway networks, and are suitable for laying
directly into the ground or in ducts.
Standards
Dlk 1.013.109y
Dlk 1.013.110y
Construction
Conductors: Solid Annealed copper, 0.9
or 1.4 mm nominal diameter.
Insulation: Solid polyethylene.
Cabling Element: Four insulated
conductors are twisted together to form a quad.
Stranding: Quads are helically stranded
in concentric layers. Cables from 7 quads
on, have two extra conductors of 0.5mm with
Outer PE Sheath
Copper Wire
PE-copolymer Coated Aluminium Tape
Quad
Solid PE Insulation
Solid Copper Conductor
Non Hygroscopic Tape
Extra Perforated Insulated Conductor
Inner PE Sheath
Double Steel Tapes
Type Codes
AJ
2Y
(L)2Y
2Y
outer PE sheath
054
www.addison-cables.com
signal cable
LG
layer stranding
H(n)
operating capacity
17mm
17mm
a-core
34mm
Side Circuit 2
side circuit 1
b-core
a-core
without ring
2
a-wire
without marking
b-wire
a-wire
b-wire
17mm
side circuit 2
b-core
17mm
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC (1min)
Maximum Conductor Capacitance @800Hz (AC)
Maximum Capacitance Unbalance @800Hz
K1 (100% / 50% all values)
K9-12 neighboured quads
K9-12 over-neighboured quads
ea1/2
Miniumum Far-end Crosstalk Attenuation @90KHz
100% / 80% all values
Maximum Attenuation @90KHz
Dielectric Strength, conductor to conductor (DC voltage 1min)
Surveillance Conductors
Loop resistance, maximum
Insulation resistance
- dry cable core, minimum
- wet cable core, maximum
Optional: Nominal Reduction Factor @ 100 V/km, 16 2/3 Hz
rk 401 series
rk 501 series
rk 601 series
Operating Voltage AC/DC
Test Voltage 50 Hz 1 min
Core to Core
Core to Screen
mm
/km
M.km
nF/km
0.9
56.6
10000
45
1.4
23.4
10000
45
pF/km
pF/km
pF/km
pF/km
650/150
500/150
150
1300
650/150
500/150
150
1300
dB/km
dB/km
V
58/62
3.3
3535
33/45
2.6
3535
/km
190
190
M.km
K.km
1000
30
1000
30
0.15
0.35
0.55
420/600
0.15
0.35
0.55
420/600
Veff
Veff
2500
2500
2500
2500
Multipair/Multiquad Signalling & Control Cables for Trackside German DB Railway Standard
055
Cable Code
Outer
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
21.0
23.0
28.0
35.0
40.0
45.0
650
800
1130
1670
2180
2650
31.0
38.0
43.0
48.0
1880
2640
3310
3880
25.0
29.0
37.0
47.0
54.0
61.0
1060
1360
2040
3180
4220
5180
28.0
31.0
39.0
49.0
56.0
63.0
1650
1950
2880
4180
5330
6430
600V DC/420V AC
Zero
EMI
Anti Induction
056
UV Resistant
Water Resistant
Rated Voltage
Laid In Ducts
www.addison-cables.com
Buried in Ciround
Zero Halogen
A-2Y(L)2YB2Y S(H45)
Applications
The cables are designed for transmission of low frequent signals up to 90
KHz through symmetric circuits in railway networks, and are suitable for laying
directly into the ground or in ducts.
Standards
Dlk 1.013.109y
Dlk 1.013.110y
Outer PE Sheath
Inner PE Sheath
Extra Perforated Insulated Conductor
Construction
Solid PE Insulation
Solid Copper Conductor
Non Hygroscopic Tape
Quad
PE-copolymer Coated Aluminium Tape
One/Double Steel Tapes
Stranding: Quads are helically stranded in concentric layers. Cables from 7 quads on, have two extra conductors
of 0.5mm with perforated insulation (surveillance conductors).
Core Wrapping: Plastic tape(s) with overlapping.
Moisture Barrier: One laminated sheath made of aluminium tape (0.15mm) coated with PE-Copolymer on at least
one side is applied with longitudinally overlap.
Inner Sheath: Low density polyethylene.
Electromagnetic Shield: One helically applied steel tape (0.2-0.3mm) or two helically applied steel tapes (0.1mm).
Outer Sheath: Low density polyethylene.
Type Codes
A
(L)2Y
2Y
LG
outdoor cable
PE inner laminated sheath
PE outer sheath
layer stranding
2Y
B
S
H(n)
a-core
without ring
side circuit 1
b-core
17mm
17mm
a-core
34mm
17mm
b-core
side circuit 2
17mm
Multipair/Multiquad Signalling & Control Cables for Trackside German DB Railway Standard
057
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC (1min)
Maximum Conductor Capacitance @800Hz (AC)
Maximum Capacitance unbalance @800Hz
K1 (100% / 50% all values)
K9-12 neighboured quads
K9-12 over-neighboured quads
ea1/2
Minimum Far-end Crosstalk Attenuation @90KHz
100% / 80% all values
Maximum Attenuation @90KHz
Dielectric Strength, conductor to conductor (DC voltage 1min)
Surveillance Conductors
Loop resistance, maximum
Insulation resistance
- dry cable core, minimum
- wet cable core, maximum
Operating Voltage AC/DC
Test Voltage @50 Hz 1 min
Core to Core
Core to Screen
mm
/km
M.km
nF/km
0.9
56.6
10000
45
1.4
23.4
10000
45
pF/km
pF/km
pF/km
pF/km
650/150
500/150
150
1300
650/150
500/150
150
1300
dB/km
dB/km
V
58/62
3.3
3535
33/45
2.6
3535
/km
190
190
M.km
K.km
V
1000
30
420/600
1000
30
420/600
Veff
Veff
2500
2500
2500
2500
Cable Code
RS109y-2Y(L)2YB2Y-1Q0.9-S(H45)
RS109y-2Y(L)2YB2Y-3Q0.9-S(H45)
RS109y-2Y(L)2YB2Y-5Q0.9-S(H45)
RS109y-2Y(L)2YB2Y-7Q0.9-S(H45)
RS109y-2Y(L)2YB2Y-10Q0.9-S(H45)
RS109y-2Y(L)2YB2Y-14Q0.9-S(H45)
RS109y-2Y(L)2YB2Y-1Q1.4-S(H45)
RS109y-2Y(L)2YB2Y-3Q1.4-S(H45)
RS109y-2Y(L)2YB2Y-5Q1.4-S(H45)
RS109y-2Y(L)2YB2Y-7Q1.4-S(H45)
RS109y-2Y(L)2YB2Y-10Q1.4-S(H45)
RS109y-2Y(L)2YB2Y-14Q1.4-S(H45)
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
12.0
17.0
19.0
21.0
24.0
27.0
170
310
410
500
640
800
14.0
21.0
24.0
26.0
33.0
36.5
240
490
710
880
1190
1550
600V DC/420V AC
Zero
UV Resistant
058
Water Resistant
Rated Voltage
Laid In Ducts
Buried in Ciround
www.addison-cables.com
Zero Halogen
A-2Y(L)2Yv S(H45)
Applications
The cables are designed for transmission of low frequent signals up to 90 KHz
through symmetric circuits in railway networks, and are suitable for laying directly
into the ground or in ducts.
Standards
Dlk 1.013.109y
Dlk 1.013.110y
Construction
Reinforced PE Sheath
Extra Perforated Insulated Conductor
Solid PE Insulation
Quad
PE-copolymer Coated Aluminium Tape
concentric layers. Cables from 7 quads on, have two extra conductors of 0.5mm with perforated insulation (surveillance
conductors).
Core Wrapping: Plastic tape(s) with overlapping.
Moisture Barrier: One laminated sheath made of aluminium tape (0.15mm) coated with PE-Copolymer on at least
one side is applied with longitudinally overlap.
Outer Sheath: Polyethylene, with reinforced radial thickness.
Type Codes
A
outdoor cable
2Y
(L)2Yv
signal cable
LG
layer stranding
H(n)
operating capacity
a-core
without ring
a-wire
without marking
b-wire
a-wire
b-wire
side circuit 1
b-core
17mm
17mm
a-core
34mm
17mm
b-core
side circuit 2
17mm
Multipair/Multiquad Signalling & Control Cables for Trackside German DB Railway Standard
059
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC (1min)
Maximum Conductor Capacitance @800Hz (AC)
Maximum Capacitance Unbalance @800Hz
K1 (100% / 50% all values)
K9-12 neighboured quads
K9-12 over-neighboured quads
ea1/2
Minimum Far-end Crosstalk Attenuation @90KHz
100% / 80% all values
Maximum Attenuation @90KHz
Dielectric Strength, conductor to conductor (DC voltage 1min)
Surveillance Conductors
Loop resistance, maximum
Insulation resistance
- dry cable core, minimum
- wet cable core, maximum
Operating Voltage AC/DC
Test Voltage @50 Hz 1 min
Core to Core
Core to Screen
mm
/km
M.km
nF/km
0.9
56.6
10000
45
1.4
23.4
10000
45
pF/km
pF/km
pF/km
pF/km
650/150
500/150
150
1300
650/150
500/150
150
1300
dB/km
dB/km
V
58/62
3.3
3535
33/45
2.6
3535
/km
190
190
M.km
K.km
V
1000
30
420/600
1000
30
420/600
Veff
Veff
2500
2500
2500
2500
Cable Code
RS109y-2Y(L)2Yv-1Q0.9-S(H45)
RS109y-2Y(L)2Yv-3Q0.9-S(H45)
RS109y-2Y(L)2Yv-5Q0.9-S(H45)
RS109y-2Y(L)2Yv-7Q0.9-S(H45)
RS109y-2Y(L)2Yv-10Q0.9-S(H45)
RS109y-2Y(L)2Yv-14Q0.9-S(H45)
RS109y-2Y(L)2Yv-20Q0.9-S(H45)
RS109y-2Y(L)2Yv-30Q0.9-S(H45)
RS109y-2Y(L)2Yv-40Q0.9-S(H45)
RS109y-2Y(L)2Yv-1Q1.4-S(H45)
RS109y-2Y(L)2Yv-3Q1.4-S(H45)
RS109y-2Y(L)2Yv-5Q1.4-S(H45)
RS109y-2Y(L)2Yv-7Q1.4-S(H45)
RS109y-2Y(L)2Yv-10Q1.4-S(H45)
RS109y-2Y(L)2Yv-14Q1.4-S(H45)
RS109y-2Y(L)2Yv-20Q1.4-S(H45)
RS109y-2Y(L)2Yv-30Q1.4-S(H45)
RS109y-2Y(L)2Yv-40Q1.4-S(H45)
10.0
15.0
17.0
19.0
22.0
25.0
28.0
34.0
38.0
95
200
280
360
480
620
830
1200
1550
12.0
19.0
22.0
24.0
29.0
33.0
39.0
46.0
53.0
150
350
530
690
950
1280
1750
2550
3320
600V DC/420V AC
Zero
UV Resistant
060
Water Resistant
Rated Voltage
Laid In Ducts
Buried in Ciround
www.addison-cables.com
Nominal Weight
kg/km
Zero Halogen
Standards
Outer PE/PVC/LSZH Sheath
Double Steel Tapes
Solid Copper Conductor
Solid PE Insulation
Twisted Pair
Non Hygroscopic Tape
Inner PE/LSZH Sheath
Corrugated Copper Tape
Intermediate PE/PVC/LSZH Sheath
Construction
Conductors: Solid annealed copper, 1.0/1.5
mm nominal cross section area.
Insulation: Solid polyethylene.
Cabling Element: Each two conductors are twisted together to form a pair.
Stranding: Pairs are helically stranded in layers to form the cable core.
Core Wrapping: Plastic tape(s) with overlapping.
Inner Sheath: PE sheath. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).
Electrostatic Shield: One corrugated copper tape.
Intermediate Sheath: PE/PVC sheath. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).
Electromagnetic Shield: Two helically applied steel tapes of 0.5mm.
Outer Sheath: PE/PVC Sheath. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).
Remarks: ZPAU: PE/PVC Sheath; ZPAU-SH: LSZH Sheath.
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Minimum Insulation Resistance @500 V DC (3mins)
Maximum Mutual Capacitance @1000Hz (AC)
Maximum Capacitance Unbalance (pair to pair) @800Hz
100% cases
90% cases
Attenuation @45KHz
Characteristic Impedance @45KHz
Dielectric Strength, conductor to conductor (DC voltage 3secs)
Operating Voltage (AC/DC)
Peak Value (AC)
mm
mm
/km
M.km
nF/km
1.13
1.0
18.1
5000
55
1.38
1.5
12.31
5000
55
pF/500 m
pF/500 m
dB/km
V
V
V
400
200
2.5
120
4500
450/750
900
400
200
2.5
120
4500
450/750
900
Multipair/Multiquad Signalling & Control Cables for Trackside France RATP Railway Standard
061
Reduction Factor
Inductive Voltage (V/km) Em
Reduction Factor @50Hz Rk
28
0.75
32
0.70
37
0.60
42
0.50
47
0.40
50
0.35
70
0.30
80
0.28
100
0.26
120
0.25
170
0.24
225
0.25
No. of Pairs
Interm.
Outer
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
16.2
17.0
22.2
23.8
26.7
32.3
37.2
41.4
52.9
490
550
820
890
1080
1560
1990
2380
3700
35.0
39.5
2050
2525
RS/ZPAU-2Y2Y(K)2YB2Y-1P1S
RS/ZPAU-2Y2Y(K)2YB2Y-2P1S
RS/ZPAU-2Y2Y(K)2YB2Y-3P1S
RS/ZPAU-2Y2Y(K)2YB2Y-4P1S
RS/ZPAU-2Y2Y(K)2YB2Y-7P1S
RS/ZPAU-2Y2Y(K)2YB2Y-14P1S
RS/ZPAU-2Y2Y(K)2YB2Y-21P1S
RS/ZPAU-2Y2Y(K)2YB2Y-28P1S
RS/ZPAU-2Y2Y(K)2YB2Y-56P1S
RS/ZPAU-2Y2Y(K)2YB2Y-14P1.5S
RS/ZPAU-2Y2Y(K)2YB2Y-21P1.5S
750V DC/450V AC
EMI
Anti Induction
UV Resistant
PE Sheath
Mineral Oil
Resistant
Zero
Rated voltage
Buried in Ciround
PVC Sheath
Zero Halogen
Flame Retardant
LSZH Sheath
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
062
Laid In Ducts
Fire Retardant
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
SNCF CT 445
NF F 55-698
Construction
Conductors: Solid annealed copper, 1.0mm nominal
cross section area.
Insulation: Solid polyethylene.
Cabling Element: Two conductors are twisted to form a pair.
Stranding: Pairs are helically stranded to form the cable core.
Core Wrapping: Plastic tape(s) with overlapping.
Inner Sheath: PE. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).
Mechanical Protection: Two helically applied steel tapes (0.15, 0.2/0.5mm, depending on pair count).
Outer Sheath: PE/PVC. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).
Remark: ZPFU: PE/PVC Sheath; ZPFU-SH: LSZH Sheath.
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Minimum Insulation Resistance @500 V DC (3mins)
Maximum Mutual Capacitance (AC) @1000Hz
Maximum Capacitance Unbalance @1000Hz
Attenuation @45KHz
Characteristic Impedance @45KHz
Dielectric Strength, conductor to conductor (DC voltage 3mins)
Operating Voltage AC/DC
mm
mm
/km
M.km
nF/km
pF/500 m
dB/km
V
V
1.13
1
18.1
5000
55
400
2.5
120
4500
450/750
Multipair/Multiquad Signalling & Control Cables for Trackside France RATP Railway Standard
063
No. of
Pairs
Cable Code
RS/ZPFU-2Y2YB2Y-1P1S
RS/ZPFU-2Y2YB2Y-2P1S
RS/ZPFU-2Y2YB2Y-4P1S
RS/ZPFU-2Y2YB2Y-7P1S
RS/ZPFU-2Y2YB2Y-14P1S
RS/ZPFU-2Y2YB2Y-21P1S
RS/ZPFU-2Y2YB2Y-28P1S
RS/ZPFU-2Y2YB2Y-56P1S
1
2
4
7
14
21
28
56
Inner
Outer
Nominal Overall
Diameter
mm
11.7
12.9
16.8
19.0
24.1
27.8
31.0
40.5
Nominal
Weight
kg/km
Armour
Thickness
mm
207
257
509
653
1011
1304
1594
2630
0.15
0.2
0.2
0.5
0.5
0.5
0.5
0.5
750V DC/450V AC
UV Resistant
PE Sheath
Mineral Oil
Resistant
Rated voltage
Zero
Buried in Ciround
Laid In Ducts
PVC Sheath
Zero Halogen
Flame Retardant
LSZH Sheath
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
064
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
SNCF CT 445
NF F 55-698
Construction
Conductors: Class 1 solid copper, 1.0 mm nominal
Solid PE Insulation
Solid Copper Conductor
Twisted Pair
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Maximum Mutual Capacitance @1000Hz (AC)
Operating Voltage
mm
mm
/km
nF/km
V
1.13
1.0
18.1
55
750
Multipair/Multiquad Signalling & Control Cables for Trackside France RATP Railway Standard
065
No. of
Pairs
Cable Code
RS/ZPGU-2Y2Y(L)Y-1P1S
RS/ZPGU-2Y2Y(L)Y-2P1S
RS/ZPGU-2Y2Y(L)Y-3P1S
RS/ZPGU-2Y2Y(L)Y-7P1S
RS/ZPGU-2Y2Y(L)Y-14P1S
1
2
3
7
14
Inner
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
9.8
10.6
13.2
18.3
21.3
95
130
179
301
532
750V DC/450V AC
Mineral Oil
Resistant
UV Resistant
Rated voltage
Buried in Ciround
Laid In Ducts
PVC Sheath
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
066
www.addison-cables.com
IEC 61034/NFC20-902
EN 50268/NF C32-073
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
SNCF CT 445
NF F 55-698
Construction
Conductors: Solid annealed copper, 1.0 mm
nominal cross section area.
Insulation: Solid polyethylene.
Cabling Element: Four conductors are twisted to form a quad.
Stranding: Quads are helically stranded to get the cable core.
Core Wrapping: Plastic tape(s) with overlapping.
Inner Sheath: Low density polyethylene. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).
Electrostatic Shield: Corrugated copper tape.
Intermediate Sheath: Low density polyethylene. LSZH FR option can be offered upon request to NF C 32 070.2.2
(C1).
Electromagnetic Shield: Two helically applied steel tapes (0.5mm).
Outer Sheath: PE/PVC compound. LSZH FR option can be offered upon request to NF C 32 070.2.2 (C1).
Remarks: ZCO3: PE/PVC Sheath; ZCO3-SH: LSZH Sheath.
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Minimum Insulation Resistance @500 V DC (3mins)
Maximum Mutual Capacitance (AC) @1000Hz
Maximum Capacitance Unbalance @800Hz
Dielectric Strength, conductor to conductor (DC voltage 3mins)
Operating Voltage AC/DC
mm
mm
/km
M.km
nF/km
pF/500m
V
V
1.13
1.0
18.1
5000
40
400
4500
450/750
Multipair/Multiquad Signalling & Control Cables for Trackside France RATP Railway Standard
067
Reduction Factor
Inductive voltage(V/km)
Reduction factor @50Hz
50
0.42
70
0.30
100
0.21
370
0.16
400
0.18
470
0.31
No. of Quads
Interm.
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
27.0
29.5
1295
1490
RS/ZCO3-2Y2Y(K)2YB2Y-2Q1S
RS/ZCO3-2Y2Y(K)2YB2Y-4Q1S
750V DC/450V AC
EMI
Anti Induction
UV Resistant
PE Sheath
Mineral Oil
Resistant
Zero
Rated voltage
Buried in Ciround
PVC Sheath
Zero Halogen
Flame Retardant
LSZH Sheath
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
068
Laid In Ducts
Fire Retardant
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
NF F 55-623
Construction
Stranding: Quads are stranded in helically laid concentric layers or units to form the cable core.
Core Wrapping: Plastic tape(s) with overlapping.
Moisture Barrier: One laminated sheath made of aluminium tape coated with PE-Copolymer on at least one side
is applied with longitudinally overlap.
Inner Sheath: LSZH re retardant compound.
Armour: Two helically applied steel tapes.
Outer Sheath: LSZH re retardant compound.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Average DC Conductor Resistance
Minimum Insulation Resistance @500 V DC (3min)
Maximum Mutual Capacitance @1000Hz (AC)
Maximum Capacitance Unbalance @800Hz
K1 (side to side)
K9-12 (quad to quad)
Operating Voltages
Maximum Permissible Current
Dielectric Strength (DC voltage 1min)
Conductor to Conductor
Conductor to Screen
mm
/km
M.km
nF/km
0.6
64.0
5000
57.5
0.8
36.0
5000
57.5
1.0
23.0
5000
57.5
1.2
16.0
5000
57.5
pF/500m
pF/500m
V
A
435
220
200
0.35
435
220
400
0.63
435
220
500
1.0
435
220
750
1.4
V
V
1500
1500
2000
1500
3000
1500
3000
1500
069
Cable Code
RS/K23-2Y(L)HBH-2P0.6
RS/K23-2Y(L)HBH-4P0.6
RS/K23-2Y(L)HBH-8P0.6
RS/K23-2Y(L)HBH-14P0.6
RS/K23-2Y(L)HBH-20P0.6
RS/K23-2Y(L)HBH-28P0.6
RS/K23-2Y(L)HBH-38P0.6
RS/K23-2Y(L)HBH-56P0.6
RS/K23-2Y(L)HBH-84P0.6
RS/K23-2Y(L)HBH-112P0.6
RS/K23-2Y(L)HBH-168P0.6
RS/K23-2Y(L)HBH-224P0.6
RS/K23-2Y(L)HBH-280P0.6
RS/K23-2Y(L)HBH-336P0.6
RS/K23-2Y(L)HBH-392P0.6
RS/K23-2Y(L)HBH-448P0.6
RS/K23-2Y(L)HBH-784P0.6
RS/K23-2Y(L)HBH-896P0.6
2
4
8
14
20
28
38
56
84
112
168
224
280
336
392
448
784
896
RS/K23-2Y(L)HBH-2P0.8
RS/K23-2Y(L)HBH-4P0.8
RS/K23-2Y(L)HBH-8P0.8
RS/K23-2Y(L)HBH-14P0.8
RS/K23-2Y(L)HBH-20P0.8
RS/K23-2Y(L)HBH-28P0.8
RS/K23-2Y(L)HBH-38P0.8
RS/K23-2Y(L)HBH-56P0.8
RS/K23-2Y(L)HBH-84P0.8
RS/K23-2Y(L)HBH-112P0.8
2
4
8
14
20
28
38
56
84
112
RS/K23-2Y(L)HBH-2P1
RS/K23-2Y(L)HBH-4P1
RS/K23-2Y(L)HBH-8P1
RS/K23-2Y(L)HBH-14P1
RS/K23-2Y(L)HBH-20P1
RS/K23-2Y(L)HBH-28P1
RS/K23-2Y(L)HBH-38P1
RS/K23-2Y(L)HBH-56P1
RS/K23-2Y(L)HBH-84P1
RS/K23-2Y(L)HBH-112P1
2
4
8
14
20
28
38
56
84
112
RS/K23-2Y(L)HBH-1P1.2
RS/K23-2Y(L)HBH-2P1.2
RS/K23-2Y(L)HBH-4P1.2
RS/K23-2Y(L)HBH-8P1.2
RS/K23-2Y(L)HBH-14P1.2
RS/K23-2Y(L)HBH-20P1.2
RS/K23-2Y(L)HBH-28P1.2
1
2
4
8
14
20
28
Impact Resistant
Mineral Oil
Resistant
Spare
pairs
Outer
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
10.5
14.0
16.5
17.5
18.5
21.0
21.5
23.0
28.0
30.5
38.0
44.0
51.0
57.0
58.5
67.0
90.5
102.5
130
171
215
290
350
441
533
700
970
1190
1847
2675
3185
3680
4168
4647
7406
8315
11.5
15.5
17.5
20.5
23.0
24.5
26.5
32.0
39.0
40.5
155
216
298
412
512
637
805
1096
1504
1880
12.0
17.5
20.5
23.5
25.0
29.0
31.5
38.5
46.5
51.5
195
298
431
587
762
981
1243
1683
2340
2944
14.0
14.5
20.0
24.0
25.0
29.0
31.5
188
230
357
509
710
950
1213
Acid&Alkaline
Resistant
Laid In conduit
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
070
Fire Retardant
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
AFNOR NF F 55-624
Fire Resistant LSZH Sheath
Solid Copper Conductor
PE Insulation
Twisted Pair
Drain Wire
Synthetic Long Ribbons/Tape
Aluminium/Polyester Tape
Construction
Conductors: Solid copper conductor, 0.5/0.6/0.9 mm
nominal diameter.
Insulation: Polyethylene insulation.
Cabling Element: Each two conductors are twisted together to form a pair.
Stranding: For cables less than 15 pairs, pairs are helically stranded in concentric layers to form the cable core.
For cables from 21 to 112 pairs, pairs are stranded in concentric layers or bundles to form the cables core.
Core Wrapping: One or more synthetic long ribbons or tapes are arranged on the cable core.
Screen: Aluminium/Polyester tape.
Drain Wire: A tinned copper drain wire, 0.5mm nominal diameter.
Sheath: Fire retardant LSZH.
Optional
Armoured Cables: For armoured cable, one or more tape(s) is (are) helically applied with overlap on the screen to
form a bedding, and double steel tapes armour with a halogen-free re retardant outer sheath are applied on the bedding.
Electrical Characteristics at 20
Nominal Conductor Diameter
Minimum Insulation Resistance
Maximum Operating Voltage
Maximum Permissible Current
mm
M.km
V
A
0.5
5000
200
0.25
0.6
5000
200
0.35
0.9
5000
400
0.80
Multipair/Multiquad Signalling & Control Cables for Trackside France RATP Railway Standard
071
Number of Pairs
(n)
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
6.0
6.5
7.0
8.0
9.0
10.5
12.5
55
65
80
95
120
150
185
6.5
7.0
8.0
8.5
10.0
11.5
13.5
65
70
90
110
140
175
225
8.5
9.0
10.5
12.0
13.5
15.0
19.0
95
110
150
185
245
340
435
Cable Code
RS/K24-2Y(L)HBH-2P0.5
RS/K24-2Y(L)HBH-3P0.5
RS/K24-2Y(L)HBH-5P0.5
RS/K24-2Y(L)HBH-7P0.5
RS/K24-2Y(L)HBH-10P0.5
RS/K24-2Y(L)HBH-15P0.5
RS/K24-2Y(L)HBH-21P0.5
RS/K24-2Y(L)HBH-2P0.6
RS/K24-2Y(L)HBH-3P0.6
RS/K24-2Y(L)HBH-5P0.6
RS/K24-2Y(L)HBH-7P0.6
RS/K24-2Y(L)HBH-10P0.6
RS/K24-2Y(L)HBH-15P0.6
RS/K24-2Y(L)HBH-21P0.6
RS/K24-2Y(L)HBH-2P0.9
RS/K24-2Y(L)HBH-3P0.9
RS/K24-2Y(L)HBH-5P0.9
RS/K24-2Y(L)HBH-7P0.9
RS/K24-2Y(L)HBH-10P0.9
RS/K24-2Y(L)HBH-15P0.9
RS/K24-2Y(L)HBH-21P0.9
Impact Resistant
Mineral Oil
Resistant
Acid&Alkaline
Resistant
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
10.0
10.5
11.0
12.0
13.0
14.5
16.5
195
205
230
255
295
345
400
10.5
11.0
12.0
12.5
14.0
15.5
18.0
200
210
245
285
330
385
450
12.5
13.5
14.5
16.0
18.0
19.5
24.0
260
285
345
395
485
610
735
Laid In conduit
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
072
Fire Retardant
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
AFNOR NF F 55-633
LSPVC Sheath
Glass Silk Tapes Bedding
Twisted Pair/Quad
Solid PE Insulation
Solid Copper Conductor
Non Hygroscopic Tape
Drain Wire
Al/Nylon or Al/PE Screen
Double Steel Tapes
Construction
Conductors: Solid copper conductor, 0.6/0.8/1.0/1.2
mm nominal diameter.
Insulation: Polyethylene insulation.
Cabling Element: Pair/Quad.
Stranding: 4-pair cables are composed of pairs, while other cables are composed of star quads.
Spare Pairs: Spare pairs may be provided according to capacity of cables.
Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap.
Screen: Aluminium/Nylon tape bonded with a special PVC sealing sheath or Aluminium/PE tape bonded with a
halogen-free re-retardant sheath.
Drain Wire: A tinned copper drain wire, 0.5mm nominal diameter.
Bedding: Several glass silk tapes are helically laid with an overlap to form bedding.
Armour: Two helically applied steel tapes.
Outer Sheath: LSPVC.
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Mutual Capacity
Minimum Insulation Resistance
Maximum Operating Voltage
Maximum Permissible Current
mm
nF/km
M.km
V
A
0.6
57.5
5000
200
0.35
0.8
57.5
5000
400
0.63
1.0
57.5
5000
500
1.0
1.2
57.5
5000
750
1.4
Multipair/Multiquad Signalling & Control Cables for Trackside France RATP Railway Standard
073
Core Identification
4-pair cable:
Pair1: black/colourless
Pair3: yellow/colourless
Other cable:
Side circuit 1 of a quad
a-wire: grey
b-wire: white
Number of Pairs
RS/K13-2Y(L)2YBY-4P0.6
RS/K13-2Y(L)2YBY-8P0.6
RS/K13-2Y(L)2YBY-14P0.6
RS/K13-2Y(L)2YBY-28P0.6
RS/K13-2Y(L)2YBY-56P0.6
RS/K13-2Y(L)2YBY-4P0.8
RS/K13-2Y(L)2YBY-8P0.8
RS/K13-2Y(L)2YBY-14P0.8
RS/K13-2Y(L)2YBY-28P0.8
RS/K13-2Y(L)2YBY-56P0.8
RS/K13-2Y(L)2YBY-4P1
RS/K13-2Y(L)2YBY-8P1
RS/K13-2Y(L)2YBY-14P1
RS/K13-2Y(L)2YBY-28P1
RS/K13-2Y(L)2YBY-56P1
RS/K13-2Y(L)2YBY-2P1.2
RS/K13-2Y(L)2YBY-4P1.2
RS/K13-2Y(L)2YBY-8P1.2
RS/K13-2Y(L)2YBY-14P1.2
RS/K13-2Y(L)2YBY-28P1.2
Impact Resistant
074
Mineral Oil
Resistant
Outer
Acid&Alkaline
Resistant
Laid In conduit
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
www.addison-cables.com
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
12.5
13.5
15.5
17.5
22.0
220
260
350
480
750
14.0
15.0
18.0
21.0
28.5
280
340
470
700
1200
15.5
17.5
20.5
25.0
34.0
340
460
630
990
1700
12.5
17.0
18.5
21.5
27.5
240
420
530
740
1250
Standards
EN 50266-2-4 & IEC 60332-3(Fire performance)
EN 50268-2(Smoke density)
EN 50267-2-1(Halogen content)
EN 50267-2-2(Gases acidity)
EN 50265-2-1, IEC 60332-1, NF
C 32070 Cat C2 compliant (for PVC
sheathed cables)
Construction
Conductors: Solid Annealed copper, 1.4 mm nominal diameter (0.6 mm for the auxiliary pair).
Insulation: Polyethylene.
Cabling Element: Two insulated conductors are twisted together to form a pair.
Stranding: Pairs are helically stranded to get the cable core.
Core Wrapping: Plastic tape(s) with overlapping.
Inner Sheath: Low density polyethylene.
Moisture Barrier: Copolymer coated laminated aluminium tape.
Intermediate Sheath: LSZH re retardant compound. PE or PVC option can be offered upon request.
Mechanical Protection: Two helically applied steel tapes.
Outer Sheath: LSZH re retardant compound. PE or PVC option can be offered upon request.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum DC Conductor Resistance
Maximum Resistance Unbalance
Minimum Insulation Resistance @500 V DC (1min)
Dielectric Strength (DC voltage 1 min)
Conductor to Conductor
Conductor to Screen
Minimum Spark Test On Outer Sheath (AC voltage)
Maximum Mutual Capacitance (Data pairs)
Nominal Mutual Capacitance (Auxiliary pair)
Maximum Capacitance Unbalance
mm
/km
%
M.km
1.4
12.1
3
5000
V
V
V
nF/km
nF/km
1000
3000
5000
45
50
Multipair/Multiquad Signalling & Control Cables for Trackside France RATP Railway Standard
075
Pair to Pair
Pair to Ground
Maximum Characteristic Pair Attenuation
@2.1KHz
@4.1KHz
@9.5KHz
@20.7KHz
Minimum Near End Crosstalk Attenuation (NEXT)
@4.1KHz
@20.7KHz
Minimum Far End Crosstalk Attenuation (FEXT)
@4.1KHz
@20.7KHz
Minimum Unbalance Attenuation
Maximum Rated Voltage, between pair conductors
Maximum Rated Current
nF/500m
nF/500m
400
1500
dB/km
dB/km
dB/km
dB/km
0.64
0.76
1.05
1.28
dB/km
dB/km
54
42
dB/km
dB/km
dB
V rms
A rms
59
48
40
220
1
Number of
Pairs
Interm.
Outer
Nominal Overall
Diameter
mm
0.7
0.7
0.7
1.3
1.3
1.3
1.5
1.5
1.5
17.9
19.2
20.2
1*
2*
3
Mineral Oil
Resistant
Acid&Alkaline
Resistant
Laid In conduit
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
076
Fire Retardant
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Nominal
Weight
kg/km
428
497
562
Standards
TR2029
Construction
EPR/PE Insulation
Insulation: EPR/PE.
PCP/PVC/LSZH Sheath
Sheath: PCP/PVC/LSZH.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Minimum Insulation Resistance
Capacitance to Earth @1KHz
mm
/km
M.km
pF/km
1.5
13.7
5000
0.1
2.5
7.41
5000
0.1
750V DC/450V AC
15OD (dynamic)
Temperature Range: -20 to +85
UV Resistant
Mineral Oil
Resistant
RS2029-3G5G-1G1.5
RS2029-2YY-1G2.5
RS2029-2YH-1G2.5
11.5
12.5
12.5
30/0.25
7/0.67
7/0.67
LSZH Sheath
0.8
3.5
0.7
Rated voltage
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal Weight
kg/km
1.4
2.0
4.5
6.6
13
13
70
183
219
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
Zero Halogen
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Multipair/Multiquad Signalling & Control Cables for Trackside France RATP Railway Standard
077
EAPSP n40.9/1.3/1.4
Applications
The cables are used as railway cables and can be installed directly into the
ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Outer PE Sheath
Optional Petroleum Jelly
Solid PE Insulation
Star Quad
Solid Copper Conductor
Non Hygroscopic Tape
Inner PE Sheath
PE-copolymer Coated Aluminium Tape
Corrugated Steel Tape
Construction
Conductors: Soft annealed solid copper,
0.9/1.3/1.4 mm nominal diameter.
Insulation: PE insulation.
Cabling Element: Four insulated conductors
are twisted together to form a quad.
Stranding: Star quads are helically stranded in concentric layers.
Core Wrapping: Plastic tape(s) with overlapping.
Moisture Barrier: One laminated sheath made of aluminium tape (0.2mm thick) coated with copolymer on at least
one side is applied with longitudinally overlap.
Inner Sheath: PE sheath.
Armour: One corrugated steel tape is longitudinally applied with overlap.
Outer Sheath: PE sheath.
Optional
Jelly Filled Cables: The cable core interstices are lled with petroleum jelly to avoid longitudinal water penetration
within the cable. The water resistant filling compound is applied to the air space between non-hygroscopic tape and
shield, shield and sheath within the cable core.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Resistance Unbalance
Mutual Capacitance @800Hz
Capacitance Unbalance @800Hz
K1 mean value/individual value
K9-12 mean value/individual value
ea1/2 mean value/individual value
078
mm
/km
M.km
%
nF/km
0.9
28.5
25000
1
41
1.3
13.7
25000
1
45
1.4
11.7
25000
1
45
pF/460m
pF/460m
pF/460m
35/250
35/250
320/1200
35/250
35/250
320/1200
35/250
35/250
320/1200
www.addison-cables.com
Attenuation @1KHz
Test Voltage @50Hz 1min
Core to Core
Core to Screen
Core to Armouring
dB/km
0.7
0.5
0.46
Veff
Veff
Veff
2100
2500
2000
2100
2500
2000
2100
2500
2000
RS/EAPSP-2Y(L)2YB2Y-1Q0.9
RS/EAPSP-2Y(L)2YB2Y-3Q0.9
RS/EAPSP-2Y(L)2YB2Y-5Q0.9
RS/EAPSP-2Y(L)2YB2Y-7Q0.9
RS/EAPSP-2Y(L)2YB2Y-10Q0.9
RS/EAPSP-2Y(L)2YB2Y-14Q0.9
RS/EAPSP-2Y(L)2YB2Y-1Q1.3
RS/EAPSP-2Y(L)2YB2Y-3Q1.3
RS/EAPSP-2Y(L)2YB2Y-5Q1.3
RS/EAPSP-2Y(L)2YB2Y-7Q1.3
RS/EAPSP-2Y(L)2YB2Y-10Q1.3
RS/EAPSP-2Y(L)2YB2Y-14Q1.3
RS/EAPSP-2Y(L)2YB2Y-1Q1.4
RS/EAPSP-2Y(L)2YB2Y-3Q1.4
RS/EAPSP-2Y(L)2YB2Y-5Q1.4
RS/EAPSP-2Y(L)2YB2Y-7Q17
RS/EAPSP-2Y(L)2YB2Y-10Q1.4
RS/EAPSP-2Y(L)2YB2Y-14Q1.4
RS/EAPSP-2Y(L)2YB2Y-19Q1.4
Number of
Quads
(n)
Outer
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
15.5
19.5
22.0
24.0
27.5
30.0
240
380
490
580
750
920
16.0
20.5
26.5
27.0
30.5
34.0
270
470
680
840
1100
1400
18.0
23.0
26.5
29.0
34.0
38.0
43.0
330
560
770
950
1280
1650
2120
RS/EAPSP-R-2Y(F)(L)2YB2Y-1Q0.9
RS/EAPSP-R-2Y(F)(L)2YB2Y-3Q0.9
RS/EAPSP-R-2Y(F)(L)2YB2Y-5Q0.9
RS/EAPSP-R-2Y(F)(L)2YB2Y-7Q0.9
RS/EAPSP-R-2Y(F)(L)2YB2Y-10Q0.9
RS/EAPSP-R-2Y(F)(L)2YB2Y-12Q0.9
RS/EAPSP-R-2Y(F)(L)2YB2Y-14Q0.9
RS/EAPSP-R-2Y(F)(L)2YB2Y-19Q0.9
RS/EAPSP-R-2Y(F)(L)2YB2Y-25Q0.9
Number of
Quads
(n)
Outer
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
16.5
22.0
25.0
26.7
31.5
32.8
34.6
39.0
43.2
270
470
630
730
980
1090
1230
1560
1940
Multipair/Multiquad Signalling & Control Cables for Trackside Spain RENFE Railway Standard
079
Number of
Quads
(n)
Cable Code
RS/EAPSP-R-2Y(F)(L)2YB2Y-1Q1.3
RS/EAPSP-R-2Y(F)(L)2YB2Y-3Q1.3
RS/EAPSP-R-2Y(F)(L)2YB2Y-5Q1.3
RS/EAPSP-R-2Y(F)(L)2YB2Y-7Q1.3
RS/EAPSP-R-2Y(F)(L)2YB2Y-10Q1.3
RS/EAPSP-R-2Y(F)(L)2YB2Y-12Q1.3
RS/EAPSP-R-2Y(F)(L)2YB2Y-14Q1.3
RS/EAPSP-R-2Y(F)(L)2YB2Y-19Q1.3
RS/EAPSP-R-2Y(F)(L)2YB2Y-25Q1.3
1.3mm Conductor,
1
3
5
7
10
12
14
19
25
Outer
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
18.0
23.0
29.5
29.7
34.5
38.0
38.6
45.5
50.5
360
570
830
980
1330
1580
1710
2260
2840
300/500V
Zero
UV Resistant
080
Water Resistant
Laid In Ducts
www.addison-cables.com
Zero Halogen
CCPSSP-FR0.3 n20.9/1.4
Applications
The cables are used as railway cables and can be installed directly into the
ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Construction
Outer PE Sheath
Solid PE Insulation
Twisted Pair
Solid Copper Conductor
Non Hygroscopic Tape
Copper Tape Screen
Inner PE Sheath
Double Steel Tapes
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Mutual Capacitance @1KHz
Capacitance Unbalance @1KHz
Pair to Pair
Pair to Earth
Test Voltage @50Hz 1min
Core to Core
Core to Screen
Reduction Factor @100V/km 50Hz
mm
/km
M.km
nF/km
0.9
28.5
15000
58
1.4
11.7
15000
58
pF/km
pF/km
260
2625
260
2625
Veff
Veff
2100
2500
0.3
2100
2500
0.3
Multipair/Multiquad Signalling & Control Cables for Trackside Spain RENFE Railway Standard
081
Cable Code
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-6P0.9
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-10P0.9
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-12P0.9
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-2P1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-6P1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-7P1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-10P1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-11P1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-14P1.4
RS/CCPSSP-FR0.3-2Y(K)2YB2Y-20P1.4
Outer
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
19.2
24.0
24.5
720
1011
1067
22.5
25.5
26.9
30.9
30.9
37.1
37.9
904
1155
1258
1542
1576
1827
2214
300/500V
Zero
EMI
UV Resistant
082
Water Resistant
Laid In Ducts
www.addison-cables.com
Zero Halogen
Anti Induction
CCPSSP-FR0.1 n40.9/1.4
Applications
The cables are used as railway cables and can be installed directly into the
ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Outer PE Sheath
Solid Copper Conductor
Solid PE Insulation
Star Quad
Non Hygroscopic Tape
Copper Wire Screen
Inner PE Sheath
Double Steel Tapes
Construction
Conductors: Soft annealed solid copper, 0.9/1.4 mm
nominal diameter.
Insulation: PE insulation.
Cabling Element: Four insulated conductors are twisted
together to form a quad.
Stranding: Quads are helically stranded in concentric layers.
Core Wrapping: Two or more layers of plastic tape(s) with overlapping.
Screen: 0.9/1.2/1.4/1.8mm copper wires wrapping with one plastic tape (protection against interference).
Inner Sheath: PE sheath.
Armour: Two layers of steel tape (0.8mm thick).
Outer Sheath: PE sheath.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Mutual Capacitance @800Hz
Capacitance Unbalance @800Hz
K1 maximum individual value
K9-12 maximum individual value
ea1/2 maximum individual value
Attenuation
@1KHz
@10KHz
@30KHz
Test Voltage @50Hz 1min
Core to Core
Core to Screen
Core to Armouring
Reduction Factor @100V/km 50Hz
mm
/km
M.km
nF/km
0.9
28.5
35000
41
1.4
11.7
35000
45
pF/460m
pF/460m
pF/460m
250
250
1200
250
250
1200
dB/km
dB/km
dB/km
0.7
1.6
2.1
0.46
0.85
1.3
Veff
Veff
Veff
2100
2500
2000
0.1
2100
2500
2000
0.1
Multipair/Multiquad Signalling & Control Cables for Trackside Spain RENFE Railway Standard
083
Cable Code
RS/CCPSSP-FR0.1-2YD2YB2Y-1Q0.9
RS/CCPSSP-FR0.1-2YD2YB2Y-3Q0.9
RS/CCPSSP-FR0.1-2YD2YB2Y-5Q0.9
RS/CCPSSP-FR0.1-2YD2YB2Y-7Q0.9
RS/CCPSSP-FR0.1-2YD2YB2Y-10Q0.9
RS/CCPSSP-FR0.1-2YD2YB2Y-12Q0.9
RS/CCPSSP-FR0.1-2YD2YB2Y-14Q0.9
RS/CCPSSP-FR0.1-2YD2YB2Y-19Q0.9
RS/CCPSSP-FR0.1-2YD2YB2Y-25Q0.9
RS/CCPSSP-FR0.1-2YD2YB2Y-1Q1.4
RS/CCPSSP-FR0.1-2YD2YB2Y-3Q1.4
RS/CCPSSP-FR0.1-2YD2YB2Y-5Q1.4
RS/CCPSSP-FR0.1-2YD2YB2Y-7Q1.4
RS/CCPSSP-FR0.1-2YD2YB2Y-10Q1.4
RS/CCPSSP-FR0.1-2YD2YB2Y-12Q1.4
RS/CCPSSP-FR0.1-2YD2YB2Y-14Q1.4
RS/CCPSSP-FR0.1-2YD2YB2Y-19Q1.4
Outer
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
21.2
24.5
27.0
28.4
32.1
32.1
35.3
38.6
42.0
1140
1370
1610
1750
2060
2130
2380
2760
3150
22.7
28.0
32.0
33.9
39.2
39.2
42.6
48.5
1280
1690
2070
2320
2860
2980
3340
4160
300/500V
Zero
EMI
UV Resistant
084
Water Resistant
Laid In Ducts
www.addison-cables.com
Zero Halogen
Anti Induction
CCPSSP-R-FR0.1
Applications
The cables are used as railway cables and can be installed directly into the
ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Outer PE Sheath
Intermediate PE Sheath
Solid Copper Conductor
Solid PE Insulation
Petroleum Jelly Filling
Star Quad
Non Hygroscopic Tape
Inner PE Sheath
Copper Wire Screen
Double Steel Tapes
Construction
Conductors: Soft annealed solid copper, 0.9 mm nominal
diameter.
Insulation: PE insulation.
Cabling Element: Four insulated conductors are twisted
together to form a quad.
Stranding: Quads are helically stranded in concentric layers.
Filling: Petroleum jelly lling.
Core Wrapping: At least one layer of water swellable material with overlapping.
Inner Sheath: PE sheath.
Screen: 1.4/1.8mm copper wires wrapping with one plastic tape (protection against interference).
Intermediate Sheath: PE sheath.
Armour: Two layers of steel tape (0.8mm thick).
Outer Sheath: PE sheath.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Mutual Capacitance @800Hz
Capacitance Unbalance @800Hz
K1 maximum individual value
K9-12 maximum individual value
ea1/2 maximum individual value
Attenuation
@1KHz
@10KHz
@30KHz
Test Voltage @50Hz 1min
Core to Core
Core to Screen
Core to Armouring
Reduction Factor @100V/km 50Hz
mm
/km
M.km
nF/km
0.9
28.5
25000
41
pF/460m
pF/460m
pF/460m
250
250
1200
dB/km
dB/km
dB/km
0.7
1.6
2.1
Veff
Veff
Veff
2100
2500
2000
0.1
Multipair/Multiquad Signalling & Control Cables for Trackside Spain RENFE Railway Standard
085
Cable Code
Inter.
Outer
Maximum
Overall Diameter
mm
Nominal
Weight
kg/km
1.6
1.6
1.6
1.8
23.7
27.7
31.5
51.3
1300
1648
1984
4166
300/500V
Zero
EMI
UV Resistant
086
Water Resistant
Laid In Ducts
www.addison-cables.com
Zero Halogen
Anti Induction
CCTSST-FR0.1 n40.9/1.4
Applications
The cables are used as railway cables and can be installed directly into the
ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Construction
Conductors: Soft annealed solid copper, 0.9/1.4 mm
nominal diameter.
Insulation: PE insulation.
Cabling Element: Four insulated conductors are twisted
together to form a quad.
Stranding: Quads are helically stranded in concentric layers.
Core Wrapping: Two or more layers of plastic tape(s) with overlapping.
Screen: 0.9/1.2/1.4/1.8mm copper wires wrapping with one plastic tape (protection against interference).
Inner Sheath: LSZH sheath, coloured green.
Armour: Two layers of steel tape (0.8mm thick).
Outer Sheath: LSZH sheath, coloured green.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Mutual Capacitance @800Hz
Capacitance Unbalance @800Hz
K1 maximum individual value
K9-12 maximum individual value
ea1/2 maximum individual value
Attenuation
@1KHz
@10KHz
@30KHz
Test Voltage @50Hz 1min
Core to Core
Core to Screen
Core to Armouring
Reduction Factor @100V/km 50Hz
mm
/km
M.km
nF/km
0.9
28.5
35000
41
1.4
11.7
35000
45
pF/460m
pF/460m
pF/460m
250
250
1200
250
250
1200
dB/km
dB/km
dB/km
0.7
1.6
2.1
0.46
0.85
1.3
Veff
Veff
Veff
2100
2500
2000
0.1
2100
2500
2000
0.1
Multipair/Multiquad Signalling & Control Cables for Trackside Spain RENFE Railway Standard
087
Cable Code
Outer
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
20.6
24.7
27.3
29.6
33.5
44.2
1170
1480
1740
1950
2320
3590
39.2
3140
RS/CCTSST-FR0.1-2YDHBH-1Q0.9
RS/CCTSST-FR0.1-2YDHBH-3Q0.9
RS/CCTSST-FR0.1-2YDHBH-5Q0.9
RS/CCTSST-FR0.1-2YDHBH-7Q0.9
RS/CCTSST-FR0.1-2YDHBH-10Q0.9
RS/CCTSST-FR0.1-2YDHBH-25Q0.9
RS/CCTSST-FR0.1-2YDHBH-10Q1.4
300/500V
EMI
Anti Induction
UV Resistant
Water Resistant
Rated Voltage
Buried in Ciround
Laid In Ducts
Low Corrosivity
Low Toxicity
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
088
Fire Retardant
Zero Halogen
www.addison-cables.com
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
CCTSST-FR0.3 n41.4
Applications
The cables are used as railway cables and can be installed directly into the
ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Outer ZHLS Sheath
Solid Copper Conductor
Solid PE Insulation
Star Quad
Non Hygroscopic Tape
Copper Tape
Inner ZHLS Sheath
Double Steel Tapes
Construction
Conductors: Soft annealed solid copper, 1.4 mm nominal
diameter.
Insulation: PE insulation.
Cabling Element: Four insulated conductors are twisted
together to form a quad.
Stranding: Quads are helically stranded in concentric layers.
Core Wrapping: Two or more layers of plastic tape(s) with overlapping.
Screen: Copper tapes with overlap (protection against interference).
Inner Sheath: LSZH sheath, coloured green.
Armour: Two layers steel tape (0.8mm thick).
Outer Sheath: LSZH sheath, coloured green.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Mutual Capacitance @800Hz
Capacitance Unbalance @800Hz
K1 maximum individual value
K9-12 maximum individual value
ea1/2 maximum individual value
Test Voltage @50Hz 1min
Core to Core
Core to Screen
Reduction Factor @100V/km 50Hz
mm
/km
M.km
nF/km
1.4
11.7
35000
45
pF/460m
pF/460m
pF/460m
250
250
1200
Veff
Veff
2100
2500
0.3
089
Cable Code
Outer
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
19.0
27.1
31.0
33.1
38.4
42.2
47.2
880
1440
1826
2090
2640
3168
3861
RS/CCTSST-FR0.3-2Y(K)HBH-1Q1.4
RS/CCTSST-FR0.3-2Y(K)HBH-3Q1.4
RS/CCTSST-FR0.3-2Y(K)HBH-5Q1.4
RS/CCTSST-FR0.3-2Y(K)HBH-7Q1.4
RS/CCTSST-FR0.3-2Y(K)HBH-10Q1.4
RS/CCTSST-FR0.3-2Y(K)HBH-14Q1.4
RS/CCTSST-FR0.3-2Y(K)HBH-19Q1.4
300/500V
EMI
Anti Induction
UV Resistant
Water Resistant
Rated Voltage
Buried in Ciround
Laid In Ducts
Low Corrosivity
Low Toxicity
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
090
Fire Retardant
Zero Halogen
www.addison-cables.com
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Standards
Construction
Conductors: Class 1 solid bare copper conductor.
Insulation: Coloured cross-linked PE insulation.
Cabling Element: Each two conductors are twisted together to form a pair.
Stranding: Pairs are helically stranded in layers to form the cable core.
Core Wrapping: Plastic tape(s) with overlapping.
Inner Sheath: PE sheath.
Electrostatic Shield: One corrugated copper tape.
Intermediate Sheath: PE sheath.
Electromagnetic Shield: Two helically applied steel tapes.
Outer Sheath: Black unleaded PVC (SXCAV) or green halogen free (SXCAG) sheath.
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Minimum Insulation Resistance @500 V DC (3mins)
Maximum Mutual Capacitance @1000Hz (AC)
Maximum Reduction Factor @170V/km 50Hz
Operating Voltage
mm
mm
/km
M.km
nF/km
V
1.38
1.5
12.3
10000
60
0.24
1000
Multipair/Multiquad Signalling & Control Cables for Trackside Belgium SNCB Railway Standard
091
Cable Code
Inter.
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
16.9
23.1
26.1
32.3
38.3
42.8
513
826
1060
1571
2199
2555
RS/SXCAV-2Y2Y(K)2YBY-1P1.5S
RS/SXCAV-2Y2Y(K)2YBY-4P1.5S
RS/SXCAV-2Y2Y(K)2YBY-7P1.5S
RS/SXCAV-2Y2Y(K)2YBY-14P1.5S
RS/SXCAV-2Y2Y(K)2YBY-24P1.5S
RS/SXCAV-2Y2Y(K)2YBY-30P1.5S
SXCAG Cables
Number of
Pairs
Cable Code
Inter.
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
16.9
23.1
26.1
32.3
38.3
42.8
515
855
1095
1616
2260
2625
RS/SXCAG-2Y2Y(K)2YBH-1P1.5S
RS/SXCAG-2Y2Y(K)2YBH-4P1.5S
RS/SXCAG-2Y2Y(K)2YBH-7P1.5S
RS/SXCAG-2Y2Y(K)2YBH-14P1.5S
RS/SXCAG-2Y2Y(K)2YBH-24P1.5S
RS/SXCAG-2Y2Y(K)2YBH-30P1.5S
EMI
Anti Induction
Buried in Ciround
Laid In Ducts
PVC Sheath
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
092
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
CFF: I-EB-SK 3001.82.1000
Construction
nominal diameter.
Insulation: Solid polyethylene.
Solid PE Insulation
Inner PE Sheath
Star Quad
Optional
Unarmoured Cable: The cables offered without galvanized steel tapes (SW).
Traction Armoured Cable: The cables offered with galvanized steel at wire armour with or without protection sheath
(SW-F/FT).
Halogenfree Sheathed Cable: The cables offered with LSZH sheath according to IEC 60332-3C (SW-CLN/FN).
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance (DC)
Minimum Insulation Resistance @500 V DC (3mins)
Maximum Mutual Capacitance @800Hz
Maximum Capacitance Unbalance
In quad
Between quads
Real-ground
Operating Voltage AC/DC
mm
/km
M.km
nF/km
1.0
47.0
10000
42
1.5
20.9
10000
52
2.2
10.0
10000
60
pF/km
pF/km
pF/km
V
400
400
650
400
400
650
500/800
400
400
650
Multipair/Multiquad Signalling & Control Cables for Trackside Swiss SBB Railway Standard
093
RS/SW-CLT-2Y2YB2Y-1Q1
RS/SW-CLT-2Y2YB2Y-2Q1
RS/SW-CLT-2Y2YB2Y-3Q1
RS/SW-CLT-2Y2YB2Y-4Q1
RS/SW-CLT-2Y2YB2Y-5Q1
RS/SW-CLT-2Y2YB2Y-7Q1
RS/SW-CLT-2Y2YB2Y-10Q1
RS/SW-CLT-2Y2YB2Y-15Q1
RS/SW-CLT-2Y2YB2Y-20Q1
RS/SW-CLT-2Y2YB2Y-25Q1
RS/SW-CLT-2Y2YB2Y-30Q1
RS/SW-CLT-2Y2YB2Y-1Q1.5
RS/SW-CLT-2Y2YB2Y-2Q1.5
RS/SW-CLT-2Y2YB2Y-3Q1.5
RS/SW-CLT-2Y2YB2Y-4Q1.5
RS/SW-CLT-2Y2YB2Y-5Q1.5
RS/SW-CLT-2Y2YB2Y-7Q1.5
RS/SW-CLT-2Y2YB2Y-10Q1.5
RS/SW-CLT-2Y2YB2Y-15Q1.5
RS/SW-CLT-2Y2YB2Y-20Q1.5
RS/SW-CLT-2Y2YB2Y-25Q1.5
RS/SW-CLT-2Y2YB2Y-30Q1.5
RS/SW-CLT-2Y2YB2Y-1Q2.2
RS/SW-CLT-2Y2YB2Y-2Q2.2
RS/SW-CLT-2Y2YB2Y-3Q2.2
RS/SW-CLT-2Y2YB2Y-4Q2.2
RS/SW-CLT-2Y2YB2Y-5Q2.2
RS/SW-CLT-2Y2YB2Y-7Q2.2
RS/SW-CLT-2Y2YB2Y-10Q2.2
RS/SW-CLT-2Y2YB2Y-15Q2.2
RS/SW-CLT-2Y2YB2Y-20Q2.2
RS/SW-CLT-2Y2YB2Y-25Q2.2
RS/SW-CLT-2Y2YB2Y-30Q2.2
No. of
Quads
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
12.7
17.5
18.3
20.4
21.7
23.3
28.4
33.0
37.1
41.7
43.2
161
335
390
455
543
640
896
1260
1590
1960
2130
15.1
23.6
24.4
27.5
30.5
32.9
42.5
49.2
57.0
62.8
64.4
240
491
585
684
793
1030
1460
2060
2600
3300
3660
13.1
20.4
21.4
23.1
25.5
27.4
33.7
39.2
43.4
50.1
51.8
346
573
934
1329
1380
1730
2560
3630
4780
5850
6580
Zero
EMI
Anti Induction
094
UV Resistant
Water Resistant
Zero Halogen
www.addison-cables.com
Buried in Ciround
Laid In Ducts
Standards
BR 1932
Construction
Outer PE Sheath
Inner PE Sheath
Solid PE Insulation
aluminium tape.
Sheath: Low density polyethylene.
Core Identication: Blue & Red.
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Conductor Cross Section
Maximum Conductor Resistance
mm
mm
/km
1.27
2.5
7.41
RS1932-2Y2Y(L)2Y-1P1.27
Nominal Sheath
Thickness
mm
No. of pairs
Overall Diameter
Min/Max
mm
Nominal Weight
kg/km
12.47/12.8
136
300/500V
Zero
EMI
Anti Induction
UV Resistant
Water Resistant
Zero Halogen
Rated Voltage
Buried in Ciround
Laid In Ducts
Multipair/Multiquad Signalling & Control Cables for Trackside UK NETWORK RAIL Standard
095
Standards
RT/E/PS/00031
Construction
Conductors: Tinned copper, 0.9/1.4 mm
nominal diameter.
Insulation: Solid polyethylene.
Cabling Element: Two insulated conductors
are twisted together to form a pair.
Stranding: Pairs are helically stranded in
PE/LSZH Sheath
Solid Copper Conductor
Solid PE Insulation
Twisted Pair
Optional Petroleum Jelly
Non Hygroscopic Tape
PE-copolymer Coated Aluminium Tape
concentric layers.
Filling: Cable core interstices are filled
with a low-permitivity compound. Unlled cables
option can be offered upon request.
Core Wrapping: Plastic tape(s) with
overlapping.
Moisture Barrier: One laminated sheath
made of aluminium tape coated with PECopolymer on at least one side is applied with
longitudinally overlap.
Inner Sheath (for S/B type): Polyethylene or LSZH re retardant compound.
Mechanical Protection (for S/B type): One corrugated steel tape or brass tape is longitudinally applied with
overlap. Unarmoured cables option can be offered upon request.
Outer Sheath: Polyethylene or LSZH re retardant compound. Ruggedised PE sheath compound can be offered
upon request.
Type Codes
F1 class: Non LSZH cables.
F5 class: Unlled cables
D type: Unarmoured types
R type: Ruggedised PE sheath
096
www.addison-cables.com
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Conductor Cross Section
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC (1min)
Nominal Conductor Capacitance @800Hz/1000Hz (AC)
Dielectric Strength, conductor to screen (DC voltage 2mins)
Maximum Average Attenuation
@1.0KHz
@2.4KHz
@40KHz
@90KHz
@1.024MHz
Minimum Average Near-end Crosstalk
@1.0KHz
@2.4KHz
@40KHz
@90KHz
@1.024MHz
mm
mm
/km
M.km
nF/km
V
0.9
0.63
30.0
5000
42+3
3000
1.4
1.5
12.5
5000
47+3
3000
dB/km
dB/km
dB/km
dB/km
dB/km
0.73
1.10
2.88
3.70
11.2
0.45
0.62
1.77
2.41
7.45
dB/km
dB/km
dB/km
dB/km
dB/km
60
60
50
50
35
60
60
50
50
35
Core Identification
Pair Number
1
A Wire
WHITE
B Wire
BLUE
Pair Number
13
A Wire
YELLOW
B Wire
GREEN
WHITE
ORANGE
14
YELLOW
BROWN
WHITE
GREEN
15
YELLOW
GREY
WHITE
BROWN
16
VIOLET
BLUE
WHITE
GREY
17
VIOLET
ORANGE
RED
BLUE
18
VIOLET
GREEN
RED
ORANGE
19
VIOLET
BROWN
GREY
RED
GREEN
20
VIOLET
RED
BROWN
21
TURQUOISE
BLUE
10
RED
GREY
22
TURQUOISE
ORANGE
11
YELLOW
BLUE
23
TURQUOISE
GREEN
12
YELLOW
ORANGE
24
TURQUOISE
BROWN
Two pair cables laid up in quad formation colour coded in rotation, Orange, White, Green, Black
097
Cable Code
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
13.2
21.6
24.8
31.2
33.8
210
530
580
800
980
23.4
30.0
32.0
37.3
42.3
320
910
1101
1450
1780
RS/RT/F3-D-2Y(F)(L)2Y-2P0.9
RS/RT/F3-D-2Y(F)(L)2Y-10P0.9
RS/RT/F3-D-2Y(F)(L)2Y-12P0.9
RS/RT/F3-D-2Y(F)(L)2Y-19P0.9
RS/RT/F3-D-2Y(F)(L)2Y-24P0.9
RS/RT/F3-D-2Y(F)(L)2Y-2P1.4
RS/RT/F3-D-2Y(F)(L)2Y-10P1.4
RS/RT/F3-D-2Y(F)(L)2Y-12P1.4
RS/RT/F3-D-2Y(F)(L)2Y-19P1.4
RS/RT/F3-D-2Y(F)(L)2Y-24P1.4
Cable Code
Outer
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
22.0
30.4
33.6
40.0
42.6
399
880
963
1312
1626
32.2
38.8
40.8
46.1
51.1
608
1510
1827
2380
2954
RS/RT/F3-S-2Y(L)2YB2Y-2P0.9
RS/RT/F3-S-2Y(L)2YB2Y-10P0.9
RS/RT/F3-S-2Y(L)2YB2Y-12P0.9
RS/RT/F3-S-2Y(L)2YB2Y-19P0.9
RS/RT/F3-S-2Y(L)2YB2Y-24P0.9
RS/RT/F3-S-2Y(L)2YB2Y-2P1.4
RS/RT/F3-S-2Y(L)2YB2Y-10P1.4
RS/RT/F3-S-2Y(L)2YB2Y-12P1.4
RS/RT/F3-S-2Y(L)2YB2Y-19P1.4
RS/RT/F3-S-2Y(L)2YB2Y-24P1.4
750V DC/450V AC
UV Resistant
Water Resistant
Rated voltage
Impact Resistant
Buried in Ciround
Laid In Ducts
Zero
PE Sheath
Zero Halogen
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
098
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
RT/E/PS/00031
Outer PE/LSZH Sheath
Copper Wire
Inner PE/LSZH Sheath
Solid Copper Conductor
Solid PE Insulation
Twisted Pair
Optional Petroleum Jelly
Non Hygroscopic Tape
PE-copolymer Coated Aluminium Tape
Double Steel Tapes
Construction
Conductors: Tinned copper wire, 0.9 or
1.4 mm nominal diameter.
Insulation: Solid polyethylene.
C a b l i n g E l e m e n t : Tw o i n s u l a t e d
conductors are twisted together to form a pair.
Stranding: Pairs are helically stranded in
concentric layers.
Filling: Cable core interstices are lled with a low-permitivity compound. Unlled cables option can be offered upon
request.
Core Wrapping: Plastic tape(s) with overlapping.
Moisture Barrier: One laminated sheath made of aluminium tape coated with PE-Copolymer on at least one side
is applied with longitudinally overlap.
Inner Sheath: Polyethylene or LSZH re retardant compound.
Electrostatic Shield: One layer of helically applied copper wires.
Electromagnetic Shield: Two helically applied steel tapes.
Outer Sheath: Polyethylene or LSZH re retardant compound. Ruggedised PE sheath compound can be offered
upon request.
Type Codes
F1 class: Non LSZH cables
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Conductor Cross Section
Maximum Conductor Resistance
mm
mm
/km
0.9
0.63
30.0
1.4
1.5
12.5
099
M.km
nF/km
V
5000
42+3
3000
5000
47+3
3000
dB/km
dB/km
dB/km
dB/km
dB/km
0.73
1.10
2.88
3.70
11.2
0.45
0.62
1.77
2.41
7.45
dB/km
dB/km
dB/km
dB/km
dB/km
60
60
50
50
35
60
60
50
50
35
0.65
0.45
0.20
0.65
0.45
0.20
Cable Code
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-2P0.9
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-10P0.9
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-12P0.9
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-19P0.9
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-24P0.9
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-2P1.4
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-10P1.4
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-12P1.4
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-19P1.4
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-24P1.4
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
23.4
31.8
35.0
41.4
44.0
1300
1650
1760
2275
2450
33.6
40.2
42.2
47.5
52.5
1480
2200
2325
2975
3150
750V DC/450V AC
EMI
Anti Induction
PE Sheath
UV Resistant
Water Resistant
Rated voltage
Impact Resistant
Buried in Ciround
Laid In Ducts
Zero
Zero Halogen
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
100
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
SNCF CT 446
Construction
Twisted Pair
Galvanized Steel Braid Armour
Inner PE Sheath
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Characteristic Impedance @100KHz
Maximum Attenuation @50KHz
Nominal Insulation Thickness
Operating Voltage
mm
mm
/km
dB/km
mm
V
0.8
0.5
36
120
5
0.55
500
Flexible
7/0.32
Laid In Ducts/
Channel
Nominal Sheath
Thickness
mm
Inner
Outer
Nominal
Overall
Diameter
mm
1.0
1.5
9.1
Nominal
Weight
kg/km
97
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
101
EUROBALISE SIF
Applications
The cables are used in Eurobalise (ERTMS) speed control circuits. The
cables are laid in trays alongside railway lines and connect anEurobalise
located between the rails to the Eurocoder (LEU) located in a control centre.
Standards
ALSTOM 5 326 203
SNCF CT 446
Construction
Outer FRPVC Sheath
Solid PE Insulation
Stranded Copper Conductor
Inner PE Sheath
Double Corrugated Copper Braid Screen
Intermediate PE Sheath
Galvanized Steel Braid Armour
Electrical Characteristics at 20
Nominal Conductor Diameter
Nominal Cross Section Area
Maximum Conductor Resistance (DC)
Nominal Characteristic Impedance @100 KHz-1MHz
Maximum Attenuation
@560 kHz
@1MHz
Nominal Insulated Thickness
mm
mm
/km
1.04
0.85
22
95
dB/km
dB/km
mm
7.5
10
0.63
7/0.386
Nominal Sheath
Thickness
mm
Inner Inter. Outer
1.0
0.8
450/750V
Mineral Oil
Resistant
102
www.addison-cables.com
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
1.6
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
15
301
EUROBALISE BGA
Applications
The cables are used as balise cables for ERTMS (European Rail Traffic
Management System) railway networks. The cables are armoured and can provide
low reduction factor.
Standards
CEI 20-11
Outer PE Sheath
Double Galvanized Steel Tapes
Solid PE Insulation
Solid Copper Conductor
Core Wrapping
Inner PE Sheath
Al/Polyethylene Tape Screen
Drain Wire
Intermediate PE Insulation
CEI 20-14
CEI 20-29
CEI 20-34
CEI 46-4
CEI 103-10
Construction
Conductors: Solid annealed copper, 1.6 mm nominal diameter.
Insulation: Solid polyethylene.
Stranding: Conductors will be stranded with dielectric llers in order to get a circular core shape.
Core Wrapping: Plastic tape (s) with overlapping.
Inner Sheath: Low density polyethylene.
Screen: Aluminium/polyethylene tape longitudinally applied and overlapped.
Drain Wire: Tinned copper drain wire
Intermediate Sheath: Low density polyethylene.
Armour: Two galvanized steel tapes.
Outer Sheath: Low density polyethylene.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance (DC)
Mutual Capacitance
Nominal Characteristic Impedance @8.9 KHz
Nominal Characteristic Impedance @560 KHz
mm
1.6
/km
21.5
nF/km
42.3+/-15%
130
110
dB/km
3.8
Insulation Resistance
M.km
10000
1000
3000
0.6
103
Number of Pairs
RS/BGA-2Y2Y(L)2YB2Y-1P1.6
Inter.
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
16
334
Zero
EMI
Anti Induction
104
UV Resistant
Water Resistant
Mineral Oil
Resistant
Rated Voltage
www.addison-cables.com
Laid In Ducts
Zero Halogen
Standards
RATP K27 specication
Fire resistant: class CR1
No re propagation: class C1 RATP (<30cm)
Construction
Electrical Characteristics at 20
Number of strands/Nominal Conductor Diameter
mm
7/1.04
1/1.39
1/1.79
1/2.25
mm
1.5
2.5
mm
1.0
0.8
1.0
1.0
Operating Voltage
300/500
105
Number of
Cores
Outer
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
17.0
406
1.0
1.5
1.0
1.5
11.3
200
RS/K27-SZ1F3Z1-U(AS+)-3G1.5
1.0
1.5
12.5
237
12
1.0
1.5
18.9
596
RS/K27-SZ1F3Z1-U(AS+)-12G1.5
1.0
1.5
13.2
265
1.0
1.5
13.5
309
1.0
1.5
14.7
325
RS/K27-SZ1F3Z1-U(AS+)-3G4
1.0
1.5
15.6
411
Impact Resistant
Mineral Oil
Resistant
Acid&Alkaline
Resistant
Laid In conduit
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
106
FE
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Standards
Fire retardant: NBN C 30-004 F2
Fire resistant: NBN 713-020 Add.3. -RF 1h
Construction
Star Quad
Non Hygroscopic Tape
Inner LSZH Sheath
Copper Tape Screen
Intermediate LSZH Sheath
Electrical Characteristics at 20
Nominal Conductor Diameter
mm
0.8
mm
0.5
mm
0.5
/km
36.7
M.km
100
Maximum Capacitance
nF/km
120
KVac
0.5
107
No. of
Quads
Cable Code
Inner
Interm.
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
30.7
1074
1.0
1.0
1.8
300/500V
EMI
Anti Induction
Rated Voltage
Laid In Ducts
Buried in Ciround
V
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
108
FE
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
RAILSIG/RAILOPTICS/
RAILDATA/RAILCOX
Railway Telecom Cables
Telecommunication Cables for Outdoor Plant
UK NETWORK RAIL Standard
UK LU London Underground Standard
France RATP Railway Standard
Telecommunication Cables for Indoor Plant
France RATP Railway Standard
109
Standards
NR/PS/TEL/00015 (formerly RT/E/PS/00015 or GK/RT 0315)
TS0886/BR1822
BR892
PE/LSZH Sheath
Solid Copper Conductor
Solid PE Insulation
Construction
Twisted Pair
Cabling Element: Two insulated conductors are twisted together to form a pair.
Stranding: Pairs are helically stranded in 10 pair units.
Core Wrapping: Plastic tape(s) with overlapping.
Moisture Barrier: One laminated sheath made of aluminium tape (0.15mm) coated with PE-Copolymer on at least
one side is applied with longitudinally overlap.
Outer Sheath: Polyethylene to BS 6234. LSZH compound option can be offered upon request.
Optional
Jelly Filled Cables: The cable core interstices are lled with petroleum jelly to avoid longitudinal water penetration
within the cable. The water resistant filling compound is applied to the air space between non-hygroscopic tape and
shield, shield and sheath within the cable core.
Armoured Cables: Corrugated steel tape armour coated on both sides with copolymer can be applied over an
intermediate sheath. The steel tape thickness is 0.145mm. Brass tape armour can be offered as an option.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC (1min)
Maximum Conductor Capacitance @1000Hz (AC)
110
www.addison-cables.com
mm
/km
M.km
0.63
60.0
1500
0.9
30.0
1500
www.caledonian-cables.co.uk
nF/km
nF/km
70
67
79
75
nF/km
nF/km
79.0
75.0
85.0
81.0
pF/500m
pF/500m
V
800
275
2000
800
275
2000
dB/km
dB/km
dB/km
1.40
2.15
18.70
0.95
1.46
14.6
dB/km
dB/km
70
65
70
65
dB/km
dB/km
40
47
40
47
V
V
2000
1333
2000
1333
Core Identification
Colour scheme, unit binder colour and cable make-up according to NR/PS/TEL/00015
Number and Pair Size of Unit
Pair Number
A Wire
B Wire
Unit Number
Binder Colour
Cable Size
Centre
1st Layer
1
2
3
4
5
6
7
8
9
10
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
1
2
3
4
5
6
7
8
9
10
BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
RED
BLACK
YELLOW
VIOLET
2
5
10
20
20
30
30
50
50
75
100
1x2
1x5
1x10
4x5
2x10
6x5
3x10
5x10
1x10
3x5
2x10
4x10
6x10
8x10
100
3x10
7x10
100
4x5
8x10
RS/RT/ZHLS-2Y(L)2Y-2P0.63
RS/RT/ZHLS-2Y(L)2Y-5P0.63
Number of Pairs
(n)
Nominal Sheath
Thickness
mm
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
12.3
13.8
103
155
111
Number of Pairs
(n)
Cable Code
RS/RT/ZHLS-2Y(L)2Y-10P0.63
RS/RT/ZHLS-2Y(L)2Y-20P0.63
RS/RT/ZHLS-2Y(L)2Y-30P0.63
RS/RT/ZHLS-2Y(L)2Y-50P0.63
RS/RT/ZHLS-2Y(L)2Y-75P0.63
RS/RT/ZHLS-2Y(L)2Y-100P0.63
Nominal Sheath
Thickness
mm
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
15.6
18.1
20.4
24.2
28.2
31.0
212
309
403
574
779
974
13.3
15.6
18.1
21.9
25.2
30.0
35.8
39.1
131
208
305
477
639
951
1325
1688
10
2.7
20
2.7
30
2.7
50
2.7
75
2.7
100
2.7
0.9mm Conductor, 1.5mm Insulated Wire
2
2.7
5
2.7
10
2.7
20
2.7
30
2.7
50
2.7
75
2.7
100
2.7
RS/RT/ZHLS-2Y(L)2Y-2P0.9
RS/RT/ZHLS-2Y(L)2Y-5P0.9
RS/RT/ZHLS-2Y(L)2Y-10P0.9
RS/RT/ZHLS-2Y(L)2Y-20P0.9
RS/RT/ZHLS-2Y(L)2Y-30P0.9
RS/RT/ZHLS-2Y(L)2Y-50P0.9
RS/RT/ZHLS-2Y(L)2Y-75P0.9
RS/RT/ZHLS-2Y(L)2Y-100P0.9
Cable Code
Nominal Sheath
Thickness
mm
Inner
RS/RT/ZHLS-2Y(F)(L)2YB2Y-2P0.63
RS/RT/ZHLS-2Y(F)(L)2YB2Y-5P0.63
RS/RT/ZHLS-2Y(F)(L)2YB2Y-10P0.63
RS/RT/ZHLS-2Y(F)(L)2YB2Y-20P0.63
RS/RT/ZHLS-2Y(F)(L)2YB2Y-30P0.63
RS/RT/ZHLS-2Y(F)(L)2YB2Y-50P0.63
RS/RT/ZHLS-2Y(F)(L)2YB2Y-75P0.63
RS/RT/ZHLS-2Y(F)(L)2YB2Y-100P0.63
RS/RT/ZHLS-2Y(F)(L)2YB2Y-2P0.9
RS/RT/ZHLS-2Y(F)(L)2YB2Y-5P0.9
RS/RT/ZHLS-2Y(F)(L)2YB2Y-10P0.9
RS/RT/ZHLS-2Y(F)(L)2YB2Y-20P0.9
RS/RT/ZHLS-2Y(F)(L)2YB2Y-30P0.9
RS/RT/ZHLS-2Y(F)(L)2YB2Y-50P0.9
RS/RT/ZHLS-2Y(F)(L)2YB2Y-75P0.9
RS/RT/ZHLS-2Y(F)(L)2YB2Y-100P0.9
Outer
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
18.0
19.5
20.3
23.8
26.1
29.9
33.9
36.7
222
296
383
504
606
903
1202
1463
19.0
21.3
23.8
27.6
30.9
35.7
41.5
44.8
250
370
508
782
1000
1402
2055
2550
600V DC/420V AC
Zero
UV Resistant
112
Laid In Ducts
Buried in Ciround
www.addison-cables.com
Zero Halogen
Standards
NR/PS/ELP/27220 (formerly RT/E/PS/0034)
Construction
Conductors: Class 1 solid plain copper
Outer PE Sheath
Inner PE Sheath
Solid Copper Conductor
PE Insulation
Twisted Pair
PE-copolymer Coated Aluminium Tape
PETP Tape
Petroleum Jelly Filling
Aluminium Wire Screen
Moisture Barrier: One laminated sheath made of aluminium tape coated with PE-Copolymer on at least one side
is applied with longitudinally overlap.
Inner Sheath: Low density polyethylene type 03C to BS 6234.
Screen: Aluminium wire screen.
Core Wrapping: Water blocking tape.
Sheath: Low density polyethylene type 03C to BS 6234.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
mm
0.9
/km
30.0
nF/km
71
pF/500m
275
113
Number of Pairs
Nominal Sheath
Thickness
mm
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
755
10
1.8
25.8
RS27220-2Y(F)(L)2YB2Y-20P0.9
20
1.8
27.8
946
RS27220-2Y(F)(L)2YB2Y-30P0.9
30
2.0
31.8
1225
RS27220-2Y(F)(L)2YB2Y-50P0.9
50
2.0
35.8
1643
RS27220-2Y(F)(L)2YB2Y-75P0.9
75
2.2
41.6
2240
RS27220-2Y(F)(L)2YB2Y-100P0.9
100
2.2
46.6
2780
600V DC/420V AC
Zero
UV Resistant
114
Laid In Ducts
Zero Halogen
www.addison-cables.com
RAILOPTICS RAILWAY
FIBER CABLES
Standards
NR/PS/TEL/00014 (formerly RT/E/PS/00014)
Construction
PE Tube
non-metallic.
Binding Tape: Polymeric loose tubes lled with water blocking material.
Inner Sheath: PE (Polyethylene) Type 03C to BS 6234 or LSZH Sheath.
Sheath: PE (Polyethylene) Type 03C to BS 6234 or LSZH sheath.
Optional
Armoured Cables: Corrugated steel tape armoured cables can be offered as an option.
Electrical Characteristics at 20
Maximum Attenuation
@1310nm
@1550nm
Maximum Chromatic Dispersion
Between 1260 and 1360nm
Between 1530 and 1565nm
Zero Dispersion Wavelength
Zero Dispersion Slope
Numerical Aperture
Point discontinuity
PMD (individual ber)
Maximum Cutoff Wavelength
Cladding Diameter
Core/Cladding Concentricity Error
dB/km
dB/km
ps/(nm/km)
ps/(nm/km)
nm
ps/(nm2.km)
dB
ps/km
nm
um
um
G652
0.35
0.22
3.5
19
131011
0.09
0.14
0.1
0.2
1260
1251
0.5
115
%
%
Kpsi (GN/m2)
N/cm
N
1
6
100 (0.7)
300
From 12 to 72 FO: 2500;144 FO: 3000
No. of bres
Nominal Cladding
Thickness
m
8
12
20
48
96
125
125
125
125
125
RO14-ML-B-9-24-F-2Y2Y
RO14-ML-B-9-26-F-2Y2Y
RO14-ML-B-9-45-F-2Y2Y
RO14-ML-B-9-86-F-2Y2Y
RO14-ML-B-9-166-F-2Y2Y
Nominal Sheath
Thickness
mm
Inner
Outer
Nominal
Overall
Diameter
mm
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
12.0
12.0
12.0
12.6
14.0
Nominal Weight
kg/km
110
110
110
120
150
No. of bres
Nominal Cladding
Thickness
m
8
12
20
48
96
125
125
125
125
125
RO14-ML-B-9-24-F-2Y(STA)2Y
RO14-ML-B-9-26-F-2Y(STA)2Y
RO14-ML-B-9-45-F-2Y(STA)2Y
RO14-ML-B-9-86-F-2Y(STA)2Y
RO14-ML-B-9-166-F-2Y(STA)2Y
Nominal Sheath
Thickness
mm
Inner
Outer
Nominal
Overall
Diameter
mm
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
15.0
15.0
15.0
15.5
17.0
Nominal
Weight
kg/km
210
210
210
230
270
600V DC/420V AC
PE Sheath
Rated Voltage
Laid In Ducts
Zero
Zero Halogen
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
116
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
www.caledonian-cables.co.uk
Standards
LUL Spec G7621 A2 type 1 (for PVC sheath)
Non-hygroscopic Tape
Construction
Cellular PE Insulation
PVC/LSZH Sheath
Core Identification
1 Pair Cable: Blue/White
3 Pair Cable: Blue/White
Orange/White
Green/White
Electrical Characteristics at 20
Nominal Conductor Diameter
mm
0.63
0.9
Average Value
/km
57.5
28
Individual Value
/km
59
29
M.km
1500
1500
nF/km
59
59
Pair to Pair
pF/460m
100
100
Pair to Earth
pF/460m
1200
1200
117
Nominal Weight
kg/km
Cable Code
No. of pairs
RS7621A2/T1-02YY-1P0.63
2.5
7.0
60
RS7621A2/T1-02YY-3P0.63
2.5
9.0
90
2.5
8.0
70
RS7621A2/T1-02YY-3P0.9
2.5
10.0
120
750V DC/450V AC
Mineral Oil
Resistant
Laid In Ducts
PVC Sheath
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
118
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
www.caledonian-cables.co.uk
Standards
LUL Spec G7622 A1 type 1 (for PVC sheath)
LUL Spec G7622 A1 type 2 (for LSZH
sheath)
Quad
Cellular PE Insulation
Construction
Cabling Element: Four insulated conductors are twisted together to form a quad.
Stranding: Conductors are helically stranded in concentric layers.
Core Wrapping: Plastic tape (s) with overlapping.
Moisture Barrier: One laminated sheath made of aluminium tape (0.15mm thick) coated with PE-Copolymer on at
least one side is applied with longitudinally overlap.
Outer Sheath: LSZH sheath, coloured violet.
Optional
Type 1 Cables: For type 1 cables, additional foil (at least one polyester tape) and PVC sheath are applied over the
LSZH sheath. (VDE Code: A-02Y(L)HY)
Armoured Cables: Corrugated steel tape armour is applied with an overlap over LSZH sheath. An outer LSZH
sheath is applied over the armour. (VDE Code: A-02Y(L)H(SR)H)
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Average Value
Individual Value
Minimum Insulation Resistance @500 V DC
Maximum Average Mutual Capacitance
Maximum Average Capacitance Unbalance
Between pairs in same quad
mm
0.63
0.9
/km
/km
M.km
nF/km
57.5
59
1500
59
28
29
1500
59
pF/460m
50
50
119
pF/460m
pF/460m
pF/460m
30
200
300
30
200
300
Core Identication
Quad colours in centre and even layers
Centre and Even Layers
1 Quad (Marker)
Even Quads
Odd Quads
Last Quad
A Wire
B Wire
C Wire
D Wire
ORANGE
RED
BROWN
ORANGE
WHITE
WHITE
WHITE
WHITE
BLUE
VIOLET
GREEN
RED
GREY
YELLOW
GREY
GREEN
Even Quads
Odd Quads
Last Quad
Odd Layers
A Wire
B Wire
C Wire
D Wire
ORANGE
RED
BROWN
ORANGE
BLACK
BLACK
BLACK
BLACK
BLUE
VIOLET
GREEN
RED
GREY
YELLOW
GREY
GREEN
Make-up of cable
Number of Quads in centre and successive layers
Number of
Pairs
Centre
1st Layer
2ndLayer
3th Layer
4th Layer
5th Layer
6th Layer
8
14
20
28
38
54
74
104
160
228
308
4
1
2
4
1
3
1
4
4
4
4
6
8
10
6
9
6
10
10
10
10
12
15
12
16
16
16
16
18
22
22
22
22
28
28
28
34
34
40
120
No. of pairs
Minimum Sheath
Thickness
mm
www.addison-cables.com
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
14.5
16.0
17.5
19.5
21.5
23.5
25.5
29.0
34.0
39.0
190
240
310
380
470
610
780
1020
1498
1993
www.caledonian-cables.co.uk
Cable Code
Minimum Sheath
Thickness
mm
No. of pairs
RS7622A1/T2-02Y(L)H-308P0.63
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
43.5
2670
17.5
20.0
22.5
24.5
25.5
29.0
32.5
37.5
280
380
500
630
790
1060
1370
1830
308
2.5
0.9mm Conductor, 1.5mm Insulated Wire
8
2.5
14
2.5
20
2.5
28
2.5
38
2.5
54
2.5
74
2.5
108
2.5
RS7622A1/T2-02Y(L)H-8P0.9
RS7622A1/T2-02Y(L)H-14P0.9
RS7622A1/T2-02Y(L)H-20P0.9
RS7622A1/T2-02Y(L)H-28P0.9
RS7622A1/T2-02Y(L)H-38P0.9
RS7622A1/T2-02Y(L)H-54P0.9
RS7622A1/T2-02Y(L)H-74P0.9
RS7622A1/T2-02Y(L)H-108P0.9
No. of
pairs
Cable Code
Inner
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
20.5
22.0
23.5
25.5
27.5
29.5
31.5
35.0
330
390
480
560
660
830
1010
1290
23.5
26.0
28.5
30.5
31.5
35.0
38.5
43.5
440
550
700
840
1020
1310
1650
2160
RS7622A1/T1-02Y(L)HY-8P0.63
RS7622A1/T1-02Y(L)HY-14P0.63
RS7622A1/T1-02Y(L)HY-20P0.63
RS7622A1/T1-02Y(L)HY-28P0.63
RS7622A1/T1-02Y(L)HY-38P0.63
RS7622A1/T1-02Y(L)HY-54P0.63
RS7622A1/T1-02Y(L)HY-74P0.63
RS7622A1/T1-02Y(L)HY-104P0.63
RS7622A1/T1-02Y(L)HY-8P0.9
RS7622A1/T1-02Y(L)HY-14P0.9
RS7622A1/T1-02Y(L)HY-20P0.9
RS7622A1/T1-02Y(L)HY-28P0.9
RS7622A1/T1-02Y(L)HY-38P0.9
RS7622A1/T1-02Y(L)HY-54P0.9
RS7622A1/T1-02Y(L)HY-74P0.9
RS7622A1/T1-02Y(L)HY-104P0.9
Cable Code
RS7622A1/T2-02Y(L)H(SR)H-8P0.63
RS7622A1/T2-02Y(L)H(SR)H-14P0.63
RS7622A1/T2-02Y(L)H(SR)H-20P0.63
RS7622A1/T2-02Y(L)H(SR)H-28P0.63
RS7622A1/T2-02Y(L)H(SR)H-38P0.63
RS7622A1/T2-02Y(L)H(SR)H-54P0.63
RS7622A1/T2-02Y(L)H(SR)H-74P0.63
RS7622A1/T2-02Y(L)H(SR)H-104P0.63
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
18.2
19.0
21.2
22.6
24.2
26.7
29.2
32.6
430
500
600
690
810
980
1190
1480
750V DC/450V AC
PVC Sheath
Mineral Oil
Resistant
Flame Retardant
Laid In Ducts
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
121
Standards
LUL Spec G7623 A2
Construction
Non-hygroscopic Tape
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Maximum Average Mutual Capacitance @1KHz
Maximum Average Capacitance Unbalance @800Hz pair-to-pair
Test Voltage AC 1min
mm
/km
M.km
nF/km
V
0.5
98
120
80
500
500
0.6
68
120
80
500
500
0.63
58
120
80
500
500
Core Identification
Colour scheme, unit binder colour and cable make-up according to G7623
Pair Size
Pair
Number
A Wire
B Wire
1
2
3
4
5
6
7
8
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
122
Center
1st Layer
2nd Layer
1
2
3
4
5
6
7
8
20 Pair
40 Pair
ORANGE
ORANGE
GREEN
www.addison-cables.com
80 Pair
100 Pair
Number of Units
1
3x1/2
6x1/2*
7x1/2
ORANGE
ORANGE
NATURAL
GREEN
BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
RED
BLACK
160 Pair
320 Pair
2
6
1
5
ORANGE
GREEN
ORANGE
NATURAL
NATURAL
NATURAL
NATURAL
GREEN
10
ORANGE
ORANGE
NATURAL
NATURAL
NATURAL
GREEN
ORANGE
NATURAL
9
10
11
12
13
14
15
16
17
18
19
20
RED
RED
BLACK
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
9
10
11
12
13
14
15
16
YELLOW
VIOLET
NATURAL
NATURAL
NATURAL
NATURAL
NATURAL
NATURAL
NATURAL
GREEN
No. of pairs
RS7623A2-HH-1P0.5
RS7623A2-HH-2P0.5
RS7623A2-HH-3P0.5
RS7623A2-HH-6P0.5
RS7623A2-HH-10P0.5
RS7623A2-HH-20P0.5
RS7623A2-HH-40P0.5
RS7623A2-HH-80P0.5
RS7623A2-HH-100P0.5
RS7623A2-HH-160P0.5
1
2
3
6
10
20
40
80
100
160
RS7623A2-HH-1P0.6
RS7623A2-HH-2P0.6
RS7623A2-HH-3P0.6
RS7623A2-HH-6P0.6
RS7623A2-HH-10P0.6
RS7623A2-HH-20P0.6
RS7623A2-HH-40P0.6
RS7623A2-HH-80P0.6
RS7623A2-HH-100P0.6
RS7623A2-HH-160P0.6
1
2
3
6
10
20
40
80
100
160
RS7623A2-HH-1P0.63
RS7623A2-HH-3P0.63
RS7623A2-HH-5P0.63
RS7623A2-HH-6P0.63
RS7623A2-HH-10P0.63
RS7623A2-HH-12P0.63
RS7623A2-HH-160P0.63
1
3
5
6
10
12
160
Nominal Weight
kg/km
6.0
7.0
7.0
9.0
11.0
14.0
16.0
23.0
25.0
29.0
30
45
50
61
107
190
320
640
760
1150
6.0
7.0
7.0
9.0
11.0
14.0
18.0
25.0
27.0
33.0
35
50
60
85
145
245
410
830
980
1450
5.5
7.3
8.5
8.9
11.1
11.6
35.0
40
70
89
100
170
195
1595
750V DC/450V AC
Mineral Oil
Resistant
Rated voltage
Buried in Ciround
Laid In Ducts
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
123
Standards
SNCF CT 2328 (Main cables) /SNCT CT 2329 (Branch cables)
Construction
CT2328 Type (Main Cables)
C o n d u c t o r s : S o l i d c o p p e r,
0.8mm nominal diameter
Insulation: Coloured solid
polyethylene.
Outer PE Sheath
Double Steel Tapes
Solid Copper Conductor
PE Insulation
Optional Aluminium Screen
PE Coated Al Tape Screen + Tinned Drain Wire
Inner PE Sheath
Corrugated Copper Tape
Intermediate PE Sheath
Optional
CT2329 Type (Branch Cables): For CT 2329 type, the cables have PE inner sheath, double corrugated steel tapes
armour and PE outer sheath, without aluminium tape screen & copper tape.
Electrical Characteristics at 20
Nominal Conductor Diameter
Maximum Conductor Resistance (DC)
Minimum Insulation Resistance @500 V DC (3mins)
Mutual Capacitance @800Hz
Average Capacitance Unbalance
Main Cables
In quad
Between quads
124
www.addison-cables.com
mm
/km
M.km
nF/km
0.8
73.4
15000
51
pF/1450 m
pF/1450 m
50
30
RAILOPTICS RAILWAY
FIBER CABLES
Real-ground
Branch Cables
In quad
Between quads
Real-ground
Maximum Attenuation @1MHz
Maximum Reduction Factor for Main Cables @100V/km 50Hz
14 quads
21 quads
28 quads
Dielectric Strength (DC voltage 1min)
Conductor to Conductor
Conductor to Screen
pF/1450 m
200
pF/1450 m
pF/1450 m
pF/1450 m
dB/km
100
100
700
15.9
0.3
0.2
0.18
V
V
1500
3000
No. of Quads
Inner
RS2328-2Y2Y(K)2YB2Y-14Q0.8
RS2328-2Y2Y(K)2YB2Y-21Q0.8
RS2328-2Y2Y(K)2YB2Y-28Q0.8
Interm.
Outer
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
29.2
31.3
35.5
1332
1655
2013
No. of Quads
Interm.
Outer
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
2.5
2.5
32.7
32.9
1765
1783
No. of Quads
RS2329-2Y2YB2Y-4Q0.8
RS2329-2Y2YB2Y-8Q0.8
RS2329-2Y2YB2Y-14Q0.8
Outer
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
16.4
18.8
22.3
339
477
686
750V DC/450V AC
Zero
UV Resistant
Water Resistant
Rated voltage
Zero Halogen
125
Standards
SNCF ST 2513-99
Outer PE Sheath
Construction
Electrical Characteristics at 20
Maximum Attenuation
@1310nm
@1550nm
Maximum Chromatic Dispersion
Between 1260 and 1360nm
Between 1530 and 1565nm
Zero Dispersion Wavelength
Zero Dispersion Slope
Numerical Aperture
Point discontinuity
PMD (individual ber)
Maximum Cutoff Wavelength
Cladding Diameter
Core/Cladding Concentricity Error
Cladding Non Circularity
Coating Non Circularity
Proof Test Level
Crush Resistance
Maximum Laying Tension
126
dB/km
dB/km
ps/(nm/km)
ps/(nm/km)
nm
ps/(nm2.km)
dB
ps/km
nm
um
um
%
%
Kpsi (GN/m2)
N/cm
N
www.addison-cables.com
G652
0.35
0.22
3.5
19
131011
0.09
0.14
0.1
0.2
1260
1251
0.5
1
6
100 (0.7)
300
From 12 to 72 FO: 2500;144 FO: 3000
www.caledonian-cables.co.uk
No of Tubes x No
of Fibers/Tube
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
12
1 tubes of 12 OF
1.5
11.6
112
RO2513-ML-B-9-312-F-2Y
36
3 tubes of 12 OF
1.5
11.6
112
RO2513-ML-B-9-66-F-2Y
36
6 tubes of 6 OF
1.5
11.6
112
Cable Code
RO2513-ML-B-9-112-F-2Y
RO2513-ML-B-9-612-F-2Y
72
6 tubes of 12 OF
1.5
11.6
112
RO2513-ML-B-9-1212-F-2Y
144
12 tubes of 12 OF
1.5
17.0
225
Zero
UV Resistant
Water Resistant
Laid In Ducts
Laid in Channel
Zero Halogen
127
Standards
SNCF CT 2242.6.1
Construction
Outer PE Sheath
Inner PE Sheath
PBT Polyester Tube
Non-metallic Central Reinforcement
Singlemode Optical Fibres
Corrugated Steel Tape Armour
Petroleum Jelly + Water-swelling Yarns
Electrical Characteristics at 20
Maximum Attenuation
@1310nm
@1550nm
Maximum Chromatic Dispersion
Between 1260 and 1360nm
Between 1530 and 1565nm
Zero Dispersion Wavelength
Zero Dispersion Slope
Numerical Aperture
Point discontinuity
PMD (individual ber)
Maximum Cutoff Wavelength
Cladding Diameter
Core/Cladding Concentricity Error
Cladding Non Circularity
Coating Non Circularity
Proof Test Level
Crush Resistance
Maximum Laying Tension
128
dB/km
dB/km
ps/(nm/km)
ps/(nm/km)
nm
ps/(nm2.km)
dB
ps/km
nm
um
um
%
%
Kpsi (GN/m2)
N/cm
N
www.addison-cables.com
G652
0.35
0.22
3.5
19
131011
0.09
0.14
0.1
0.2
1260
1251
0.5
1
6
100 (0.7)
450
3000
RAILOPTICS RAILWAY
FIBER CABLES
No. of bres
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
1-36
48-72
80-144
1.5
1.5
1.5
14.5
16.5
22.0
260
300
510
Zero
UV Resistant
Water Resistant
Zero Halogen
129
Standards
RATP CAT6-K20 (for K20 cable)
FRANCE TELECOM S31-10/20 & NF C 93.531-6/7 (for L120 cable)
Construction
C o n d u c t o r s : C l a s s 1 AW G 2 3 s o l i d c o p p e r
conductor (for K20 cable); 0.6mm annealed copper
conductor (for L120 cable).
Insulation: Solid polyethylene (for K20 cable);
Foam skin (cellular PE + solid PE) (for L120 cable).
Cabling Element: Two conductors are twisted
together to form a pair (for K20 cable); Four conductors
are twisted together to form a quad (for L120 cable).
Core Wrapping (for L120 cable): Non-hygroscopic
plastic tape with overlapping.
Individual Screen (for K20 cable): Alu/polyester
shield on each pair.
Overall Screen: Alu/polyester shield.
Drain Wire: Tinned copper drain wire, 0.5mm
nominal diameter.
Inner Sheath (for K20 cable): LSZH.
Armour (for K20 cable): Galvanized steel braid
armour.
Outer Sheath: LSZH.
K20
Outer LSZH Sheath
Foam Skin Insulation
Annealed Copper Conductor
Star Quad
Drain Wire
Overall Al/polyester Screen
L120
Optional
Armoured L120 Cables: Tinned copper braid armoured cables can be offered upon request.
Electrical Characteristics at 20
Nominal Conductor Diameter
AWG
Maximum Conductor Resistance
Minimum Insulation Resistance @500 V DC
Characteristics Impedance @100MHz
Maximum Capacitance Unbalance
Real/earth
Maximum Average Attenuation
@1MHz
@4MHz
@10MHz
@16MHz
@25MHz
130
mm
/km
M/km
0.56 (K20)
23
146.4
5000
100
0.6 (L120)
23
133.2
5000
120+15
pF/km
1600
300
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
2.0
3.8
6.0
7.6
9.5
2.0
3.8
6.0
7.6
9.5
www.addison-cables.com
www.caledonian-cables.co.uk
@31.25MHz
@62.5MHz
@100MHz
@250MHz
Minimum NEXT Pair to Pair
@1MHz
@4MHz
@10MHz
@16MHz
@25MHz
@31.25MHz
@62.5MHz
@100MHz
@250MHz
Minimum ELFEXT Pair to Pair
@1MHz
@4MHz
@10MHz
@16MHz
@25MHz
@31.25MHz
@62.5MHz
@100MHz
@250MHz
dB/100m
dB/100m
dB/100m
dB/100m
10.7
15.4
19.8
32.9
10.7
15.4
19.8
32.9
dB
dB
dB
dB
dB
dB
dB
dB
dB
77.3
68.3
62.3
59.2
56.3
54.9
50.4
47.3
41.3
77.3
68.3
62.3
59.2
56.3
54.9
50.4
47.3
41.3
dB
dB
dB
dB
dB
dB
dB
dB
dB
68.8
56.8
48.8
44.7
40.8
38.9
32.8
28.8
20.8
68.8
56.8
48.8
44.7
40.8
38.9
32.8
28.8
20.8
Mineral Oil
Resistant
Acid&Alkaline
Resistant
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
11.7
156
Impact Resistant
Cable Code
1.0
L120 cables
Cable Code
No. of pairs
RD/L120-F/FTPCat6-02YHH-4P0.6
RD/L120-F/FTPCat6-02YHH-8P0.6
RD/L120-F/FTPCat6-02YHH-12P0.6
RD/L120-F/FTPCat6-02YHH-32P0.6
RD/L120-F/FTPCat6-02YHH-64P0.6
RD/L120-F/FTPCat6-02YHH-128P0.6
Nominal Sheath
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
8.5 x 6*
18 x 6**
16
19
30
40
60
120
235
360
675
1250
SU=super unit. * For 4 pair L120 cable, 8 insulated wires form 2 quads and the cable is at.
** For 8 pair L120 cable, two at quads are assembled under a common LSH sheath.
Zero
Laid in Cable
Trays/on Hooks
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
131
Standards
RATP K209B or RATP K209A
Outer LSZH Sheath
Construction
Thermoplastic Tube
Optical Fibres
Compact Tube
Water-swelling Glass Yarns
Corrugated Steel Tape Armour
Optional
K209A Type: For K209A type, the cables have loose tubes with 6-12 bers, steel wire strand as central strength
member, glass yarn reinforced, incorporating a corrugated steel tape armour and an outer UV stabilized LSZH jacket.
Electrical Characteristics at 20
Optical & Geometrical Properties for Single Mode Fibers
Maximum Attenuation
@1310nm
@1550nm
Maximum Chromatic Dispersion
Between 1260 and 1360nm
Between 1530 and 1565nm
Zero Dispersion Wavelength
Zero Dispersion Slope
Numerical Aperture
Point discontinuity
PMD (individual ber)
Maximum Cutoff Wavelength
Cladding Diameter
Core/Cladding Concentricity Error
Cladding Non Circularity
Coating Non Circularity
Proof Test Level
Crush Resistance
Maximum Laying Tension
132
dB/km
dB/km
ps/(nm/km)
ps/(nm/km)
nm
ps/(nm2.km)
dB
ps/km
nm
um
um
%
%
Kpsi (GN/m2)
N/cm
N
www.addison-cables.com
G652
0.35
0.22
3.5
19
131011
0.09
0.14
0.1
0.2
1260
1251
0.5
1
6
100 (0.7)
300
3000
RAILOPTICS RAILWAY
FIBER CABLES
50/125
62.5/125
dB/km
dB/km
2.5
0.7
3.0
0.8
MHz*km
MHz*km
nm
um
um
um
um
%
%
um
Kpsi (GN/m2)
500
800
1310
0.200.015
503
1252
1.5
8
6
2 1
24510
100 (0.7)
200
500
1310
0.2750.015
62.53
1252
1.5
8
6
2 1
24510
100 (0.7)
No. of
bres
1-36
42-72
Distribution
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
1.8
1.8
12
13.5
190
230
K209B
No. of
bres
Cable Code
RO/K209B-ML-C-9-2x6-F-(STA)H
RO/K209B-ML-C-9-4x6-F-(STA)H
RO/K209B-ML-C-9-6x6-F-(STA)H
RO/K209B-ML-C-9-8x6-F-(STA)H
RO/K209B-ML-C-9-6x12-F-(STA)H
RO/K209B-ML-C-9-1x6-F-(STA)H
RO/K209B-ML-C-9-2x6-F-(STA)H
Impact Resistant
Mineral Oil
Resistant
No of Tubes x No of
Fibers/Tube
Nominal Sheath
Thickness
mm
Acid&Alkaline
Resistant
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
13
13
13
112
112
112
15.5
15.5
230
230
13
13
112
112
Laid in Cable
Trays/on Hooks
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
133
Standards
RATP K26
Fire Performance: NF C 32070.2.2
LSZH Sheath
Cellular PE/Natural PE Insulation
Construction
Inner Conductor
Inner Conductors:
Outer Conductor
50 cables:
Flexible Type (F)- solid copper coated aluminium (for 1/4 , 3/8 &1/2 F conductor); red copper tube (for
7/8 and 1'1/4 F conductor); corrugated red copper tube (for 1'5/8 F conductor).
Super Flexible Type (SF) - solid copper coated aluminium (for 3/8 & 1/2 SFconductor); helical corrugated
copper tube (for 7/8SF conductor); copper wire (for 1/4 SFconductor).
Extra Flexible (XF) copper wire (for 1/4" XF conductor); solid copper coated aluminium (for 3/8" XF
conductor).
75 cables: solid red copper (for type 11 RTC) or red copper tube (for type KX6).
Dielectric: Cellular PE or natural PE (only for KX6 type).
Outer Conductor:
50 cables: corrugated copper tube.
75 cables: copper braid.
Outer sheath: LSZH.
Electrical Characteristics at 20
50 Cables
Type of Cable
Impedance
Attenuation
@10MHz
@150MHz
@200MHz
@450MHz
@900MHz
@1000MHz
134
inch
1/4"F
50
3/8"F
50
1/2"F
50
7/8"F
50
1'1/4F
50
1'5/8F
50
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
1.25
4.99
5.8
8.8
12.8
13.5
1.46
4.22
4.90
7.51
11.1
11.6
0.65
2.61
3.04
4.66
6.78
7.18
0.34
1.45
1.69
2.61
3.81
4.04
0.25
1.02
1.19
1.86
2.75
2.93
0.2
0.85
1.00
1.57
2.34
2.49
www.addison-cables.com
@1500MHz
@1700MHz
Average Power Rating
@10MHz
@150MHz
@200MHz
@450MHz
@900MHz
@1000MHz
@1500MHz
@1700MHz
Velocity of Propagation
dB/100m
dB/100m
17.0
18.3
14.4
15.5
8.99
9.64
5.08
5.45
3.72
4.01
3.17
3.42
KW
KW
KW
KW
KW
KW
KW
KW
%
5.79
1.45
1.25
0.818
0.566
0.533
0.426
0.398
85
7.23
1.81
1.56
1.02
0.70
0.663
0.53
0.494
88
13
3.2
2.75
1.8
1.25
1.18
0.947
0.884
88
28.0
7.0
6.0
3.88
2.65
2.50
1.99
1.85
88
41
11
9.0
5.5
3.83
3.60
2.82
2.61
88
57
13
11
6.9
4.49
4.20
3.22
2.96
88
Type of Cable
Impedance
Attenuation
@10MHz
@150MHz
@200MHz
@450MHz
@900MHz
@1000MHz
@1500MHz
@1700MHz
Average Power Rating
@10MHz
@150MHz
@200MHz
@450MHz
@900MHz
@1000MHz
@1500MHz
@1700MHz
Velocity of Propagation
inch
1/4"SF
50
3/8"SF
50
1/2"SF
50
7/8"SF
50
1/4"XF
50
3/8"XF
50
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
1.71
6.89
8.01
12.31
17.92
18.98
23.78
25.51
1.3
4.89
5.59
8.49
12.66
13.5
17.43
18.91
0.83
3.87
4.53
7.09
10.45
11.09
13.98
15.03
0.39
1.59
1.85
2.85
4.15
4.4
5.52
5.92
2.31
7.44
8.54
14.3
20.5
21.83
27.13
29.5
1.098
4.38
5.098
7.83
11.4
12.1
15.1
16.2
KW
KW
KW
KW
KW
KW
KW
KW
%
2.8
0.7
0.6
0.39
0.272
0.257
0.206
0.192
83
6.0
1.52
1.31
0.86
0.593
0.56
0.449
0.42
81
8.4
2.1
1.81
1.18
0.815
0.77
0.616
0.575
82
21.5
5.4
4.6
3.0
2.07
1.95
1.55
1.45
88
3.8
0.9
0.8
0.51
0.37
0.34
0.26
0.24
84
7.02
1.76
1.51
0.99
0.68
0.64
0.51
0.48
85
75 Cables
Type of Cable
Impedance
@50MHz
@100MHz
@150MHz
@200MHz
@500MHz
@800MHz
@1000MHz
Velocity of Propagation
inch
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
dB/100m
%
11 RTC
75
2.5
3.6
4.6
5.4
8.5
10.5
12.2
87
KX6
75
8.13
11.73
14.53
16.92
27.0
35.1
40.02
66
135
Nominal Inner
Conductor Diameter
mm
Cable Code
RS/K26-F-HCAAYZ-50-6(1/4")
2.5
RS/K26-F-HCAAYZ-50-8(3/8")
3.3
RS/K26-F-HCAAYZ-50-12(1/2")
4.8
RS/K26-F-HCTAYZ-50-22(7/8")
9.0
RS/K26-F-HCTAYZ-50-32(1'1/4)
13.0
RS/K26-F-HHTAYZ-50-42(1'5/8)
17.3
RS/K26-HRYZ-50-5(1/4" SF)
1.9
RS/K26-HRCAYZ-50-7(3/8" SF)
2.8
RS/K26-HRCAYZ-50-9(1/2" SF)
3.6
RS/K26-HRCTYZ-50-22(7/8" SF)
9.4
RS/K26-HRYZ-50-5(1/4" XF)
5.75
RS/K26-HRCAYZ-50-7(3/8" XF)
2.76
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
9.5
145
11.5
204
16.0
248
27.75
575
39.5
1133
50.0
1631
7.95
99
11.15
159
13.65
201
27.5
550
6.85
69
10.1
111
75 Cables
Cable Code
Nominal Inner
Conductor Diameter
mm
RS/K26-11RTC-BC80-H
1.7
RS/K26-KX6-BC80-H
0.6
Impact Resistant
Mineral Oil
Resistant
Acid&Alkaline
Resistant
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
10.3
115
7.2
66
Laid in Ducts
/on Hooks
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
136
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
137
Standards
NF F 55-625
UNE 21123
Construction
Conductors: Stranded bare copper conductor,
1.5mm to IEC 60228 class 2.
Insulation: XLPE.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Minimum Insulation resistance @500VDC
Voltage Rating
mm
/km
M.km
KV
1.5
12.2
1500
0.6/10.45/0.75 optional
Core Identification
Colours coding: Black, Light blue, Brown, Green/Yellow, Black
138
www.addison-cables.com
Cable Code
RF/K25-RZ1F3Z1-U(AS)-0.6/1KV-2G1.5
RF/K25-RZ1F3Z1-U(AS)-0.6/1KV-4G1.5
RF/K25-RZ1F3Z1-U(AS)-0.6/1KV-12G1.5
RF/K25-RZ1F3Z1-U(AS)-0.6/1KV-21G1.5
2 x 1.5
4 x 1.5
12 x 1.5
21 x 1.5
7/0.53
7/0.53
7/0.53
7/0.53
8.0
12.5
18.0
22.0
Maximum
Overall
Diameter
mm
Nominal
Weight
kg/km
12.0
14.5
20.0
24.0
100
300
590
830
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
139
Standards
NR/PS/ELP/21101 (formerly RT/E/S/21101)
BS 638 Part 4
UNE 21027
Construction
PETP
CSP Sheath
Terephthalate).
Sheath: CSP(Chlorosulfonated Polyethylene) type RS4 to BS 6899.
H.O.F.R. heat resistant, oil resistant and ame retardant.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Conductor Material
Maximum DC Conductor Resistance
Assigned Continuous Current Rating
Voltage Rating
mm
161
/km
A
KV
0.109
550
500
copper
0.0369
1200
630
0.0286
1500
150
240
500
800
Aluminium
0.206
0.125 0.0605 0.0307
430
550
800
1200
0.45/0.75
140
www.addison-cables.com
1000
0.0291
1500
Cable Code
RF21101-H01N2-D-450/750V-1G161CU
RF21101-H01N2-D-450/750V-1G500CU
RF21101-H01N2-D-450/750V-1G630CU
RF21101-H01N2-D-450/750V-1G150AL
RF21101-H01N2-D-450/750V-1G240AL
RF21101-H01N2-D-450/750V-1G500AL
RF21101-H01N2-D-450/750V-1G800AL
RF21101-H01N2-D-450/750V-1G1000AL
Copper Conductor
1161
820/0.5
1500
1769/0.6
1630
2257/0.6
Aluminium Conductor
1150
756/0.5
1240
1221/0.5
1500
1769/0.6
1800
2825/0.6
11000
3531/0.6
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
Polarity/
Gland Size
4.0
4.0
4.0
25.9
42.3
45.9
2050
5582
6879
negative/32
negative/50
positive/63S
4.0
4.0
4.0
4.0
4.0
20.5
29.6
42.0
50.2
55.0
581
1171
2361
3498
4226
negative/25
negative/40
positive/50
negative/63S
positive/63
e
Impact Resistant
Highly Flexible
Oil Resistant
Weather Resistant
Laid In Ducts
141
Standards
EME SP 14 025 (replaced by LUL 1-108 and Metronet MR SE908)
UNE 21123
Construction
EPR Insulation
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
500
0.0361
935
0.0194
0.45/0.75
No. &
Nominal
Diameter of
Strands
No/mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
1500
1935
91/2.65
169/2.65
8.5
9.5
54.0
65.0
7185
11749
RF14025-DZ1-U(AS)-450/750V-1G500
RF14025-DZ1-U(AS)-450/750V-1G935
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
142
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
EME SP 14 026 (LUL version of BS 7211)
UNE 211002
Construction
Stranded Copper Conductor
LSZH Insulation
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
/km
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
500
630
Voltage Rating
KV
0.45/0.75
mm
95
120
150
/km
0.193
0.153
0.124
Voltage Rating
KV
185
240
300
400
143
Cable Code
RF14026-ES07Z-U(AS)-450/750V-1G1.5
RF14026-ES07Z-U(AS)-450/750V-1G2.5
RF14026-ES07Z-U(AS)-450/750V-1G4
RF14026-ES07Z-U(AS)-450/750V-1G6
RF14026-ES07Z-U(AS)-450/750V-1G10
RF14026-ES07Z-U(AS)-450/750V-1G16
RF14026-ES07Z-U(AS)-450/750V-1G25
RF14026-ES07Z-U(AS)-450/750V-1G35
RF14026-ES07Z-U(AS)-450/750V-1G50
RF14026-ES07Z-U(AS)-450/750V-1G70
RF14026-ES07Z-U(AS)-450/750V-1G95
RF14026-ES07Z-U(AS)-450/750V-1G120
RF14026-ES07Z-U(AS)-450/750V-1G150
RF14026-ES07Z-U(AS)-450/750V-1G185
RF14026-ES07Z-U(AS)-450/750V-1G240
RF14026-ES07Z-U(AS)-450/750V-1G300
RF14026-ES07Z-U(AS)-450/750V-1G400
RF14026-ES07Z-U(AS)-450/750V-1G500
RF14026-ES07Z-U(AS)-450/750V-1G630
1 x 1.5
1 x 2.5
1 x 4.0
1 x 6.0
1 x 10.0
1 x 16.0
1 x 25.0
1 x 35.0
1 x 50.0
1 x 70.0
1 x 95.0
1 x 120.0
1 x 150.0
1 x 185.0
1 x 240.0
1 x 300.0
1 x 400.0
1 x 500.0
1 x 630.0
7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.52
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.8
2.8
3.0
3.6
4.1
4.7
5.8
6.8
8.6
10.2
11.9
12.8
15.0
16.6
18.5
20.8
25.4
28.1
31.6
35.2
39.1
22
34
50
70
114
175
272
377
509
697
961
1203
1510
1855
2451
3031
3898
4894
6244
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
144
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
EME SP 14 027 (LUL version of BS 6724 for re retardant version and BS 6387 for re resisting version)
UNE 21123
Construction
Stranded Copper Conductor
XLPE Insulation
LSZH Bedding
Steel Wire Armour
LSZH Sheath
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50
/km
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
Voltage Rating
0.6/1.0
KV
mm
70.0
95
120
/km
0.268
0.193
0.153
Voltage Rating
KV
150
185
240
300
0.124
0.0991
0.0754
0.0601
0.6/1.0
145
Cable Code
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G2.5
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G4
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G6
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G10
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G16
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G25
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G35
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G50
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G70
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G95
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G120
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G150
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G185
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G240
RF14027-RZ1MZ1-U(AS)-0.6/1KV-2G300
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G2.5
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G4
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G6
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G10
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G16
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G25
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G35
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G50
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G70
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G95
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G120
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G150
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G185
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G240
RF14027-RZ1MZ1-U(AS)-0.6/1KV-3G300
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G2.5
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G4
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G6
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G10
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G16
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G25
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G35
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G50
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G70
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G95
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G120
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G150
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G185
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G240
RF14027-RZ1MZ1-U(AS)-0.6/1KV-4G300
22.5*
24.0*
26.0*
210.0*
216.0*
225.0
235.0
250.0
270.0
295.0
2120.0
2150.0
2185.0
2240.0
2300.0
32.5*
34.0*
36.0*
310.0*
316.0*
325.0
335.0
350.0
370.0
395.0
3120.0
3150.0
3185.0
3240.0
3300.0
42.5*
44.0*
46.0*
410.0*
416.0*
425.0
435.0
450.0
470.0
495.0
4120.0
4150.0
4185.0
4240.0
4300.0
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
*Circular conductors
U is changed to K if the stranding class is changed from class 2 to class 5
146
www.addison-cables.com
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
1.4
1.4
1.4
1.5
1.6
1.7
1.8
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9
12.2
13.3
14.4
16.1
18.7
21.0
22.0
24.0
27.0
32.0
35.0
38.0
43.0
49.0
54.0
12.1
13.3
14.4
17.0
19.3
24.0
27.0
28.0
32.0
36.0
40.0
44.0
49.0
56.0
62.0
13.6
14.9
17.1
18.9
21.5
27.0
29.0
32.0
37.0
41.0
46.0
51.0
55.0
63.0
68.0
323
387
460
611
904
1050
1450
1800
2300
3250
3950
4650
6050
7500
9050
335
430
523
811
1072
1750
2000
2450
3250
4500
5350
6900
8200
10350
12600
406
505
737
969
1303
2100
2450
3100
4400
5650
7300
8700
10450
13250
16100
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G2.5
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G4
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G6
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G10
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G16
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G25
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G35
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G50
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G70
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G95
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G120
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G150
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G185
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G240
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-2G300
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G2.5
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G4
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G6
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G10
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G16
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G25
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G35
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G50
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G70
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G95
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G120
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G150
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G185
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G240
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-3G300
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G2.5
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G4
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G6
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G10
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G16
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G25
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G35
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G50
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G70
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G95
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G120
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G150
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G185
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G240
RF14027-RZ1MZ1-U-MICA(AS+)-0.6/1KV-4G300
22.5
24.0
26.0
210.0
216.0
225.0
235.0
250.0
270.0
295.0
2120.0
2150.0
2185.0
2240.0
2300.0
32.5
34.0
36.0
310.0
316.0
325.0
335.0
350.0
370.0
395.0
3120.0
3150.0
3185.0
3240.0
3300.0
42.5
44.0
46.0
410.0
416.0
425.0
435.0
450.0
470.0
495.0
4120.0
4150.0
4185.0
4240.0
4300.0
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
Nominal
Nominal
Nominal
Overall
Sheath
Weight
Thickness Diameter
kg/km
mm
mm
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
1.4
1.4
1.4
1.5
1.6
1.7
1.8
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9
13.1
14.1
15.2
16.9
19.5
25.5
29.1
32.2
28.8
33.9
37.2
39.9
45.0
50.0
55.0
13.7
14.8
16.0
18.5
20.8
27.6
30.9
33.9
35.7
38.2
41.6
47.0
50.5
57.2
63.2
14.7
16.0
18.2
20.0
22.5
29.9
33.5
37.1
39.1
43.0
48.3
52.4
56.6
64.3
70.7
352
424
504
620
954
1330
1785
2165
2445
3385
4065
4745
6095
7575
9165
392
478
573
868
1136
1865
2235
2735
3355
4580
5505
6950
8295
10455
12660
454
556
783
1029
1367
2240
2705
3375
4560
5805
7430
8820
10600
13380
16255
FE
e
Impact Resistant
Highly Flexible
Oil Resistant
Weather Resistant
Laid In Ducts
147
Standards
BS 7629-1/ 5839-1: 2002/ 8434-1: 2003/6387 C W Z
BS EN 50200 (PH90)
UNE 211025
Construction
LSZH Sheath
Drain Wire
overlapping.
Screen: Aluminium/Polyester tape.
Drain Wire: Tinned copper.
Sheath: High performance, thermoplastic LSZH.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor DC Resistance
Nominal Insulation Thickness
Voltage Rating
mm
/km
mm
KV
1.0
18.1
0.6
1.5
12.1
0.7
0.3/0.5
148
www.addison-cables.com
2.5
7.41
0.8
Cable Code
RFLU12-SOZ1-U-PH90(AS+)-300/500V-2G1
RFLU12-SOZ1-U-PH90(AS+)-300/500V-3G1
RFLU12-SOZ1-U-PH90(AS+)-300/500V-4G1
RFLU12-SOZ1-U-PH90(AS+)-300/500V-7G1
RFLU12-SOZ1-U-PH90(AS+)-300/500V-2G1.5
RFLU12-SOZ1-U-PH90(AS+)-300/500V-3G1.5
RFLU12-SOZ1-U-PH90(AS+)-300/500V-4G1.5
RFLU12-SOZ1-U-PH90(AS+)-300/500V-7G1.5
RFLU12-SOZ1-U-PH90(AS+)-300/500V-2G2.5
RFLU12-SOZ1-U-PH90(AS+)-300/500V-3G2.5
RFLU12-SOZ1-U-PH90(AS+)-300/500V-4G2.5
21.0
31.0
41.0
71.0
21.5
31.5
41.5
71.5
22.5
32.5
42.5
7/0.44
7/0.44
7/0.44
7/0.44
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
1.13
1.13
1.13
1.13
1.38
1.38
1.38
1.38
1.78
1.78
1.78
1.3
1.3
1.3
1.3
1.4
1.4
1.4
1.4
1.5
1.5
1.5
7.0
7.3
8.2
10.5
7.9
8.3
9.5
12.2
9.3
9.9
11.3
Nominal
Weight
kg/km
83
95
115
175
110
128
160
250
160
190
235
FE
e
Impact Resistant
Highly Flexible
Oil Resistant
Weather Resistant
Laid In Ducts
149
Standards
EME SP 14 028
BS 6387 CWZ
BS 5839-1 Standard
BS 5839-1 Enhanced
BS 7346-6
BS EN 60702
Construction
Solid Copper Conductor
Magnesium Oxide Insulation
Copper Sheath
covering.
Electrical Characteristics at 20
Light Duty 0.5KV Grade
Nominal Conductor Diameter
mm
1.13
1.39
1.77
mm
1.0
1.5
2.5
4.0
/km
18.1
12.1
7.41
4.61
Voltage Rating
KV
2.25
0.5
mm
1.39
1.77
2.25
2.75
3.57
4.5
5.66
6.66
mm
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
/km
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
Voltage Rating
KV
7.75
0.75
mm
9.32
10.98
12.33
13.7
15.18
17.33
19.37
22.37
mm
70.0
95.0
120.0
150.0
185.0
240.0
300
400
/km
0.268
0.193
0.153
0.124
0.101
0.0775
0.0601
0.047
Voltage Rating
150
KV
www.addison-cables.com
0.75
Cable Code
No. of cores&
Nominal Conductor
Cross Sectional Area
No.mm
Cross Sectional
Area of Copper
Sheath
mm
RF14028L-MICC-300/500V-2G1
RF14028L-MICC-300/500V-2G1.5
RF14028L-MICC-300/500V-2G2.5
RF14028L-MICC-300/500V-2G4
RF14028L-MICC-300/500V-3G1
RF14028L-MICC-300/500V-3G1.5
RF14028L-MICC-300/500V-3G2.5
RF14028L-MICC-300/500V-4G1
RF14028L-MICC-300/500V-4G1.5
RF14028L-MICC-300/500V-4G2.5
RF14028L-MICC-300/500V-7G1
RF14028L-MICC-300/500V-7G1.5
RF14028L-MICC-300/500V-7G2.5
21.0
21.5
22.5
24.0
31.0
31.5
32.5
41.0
41.5
42.5
71.0
71.5
72.5
5.4
6.3
8.2
10.7
6.7
7.8
9.5
7.7
9.1
11.3
11.0
11.8
15.4
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
With
LSZH
Covering
Without
LSZH
Covering
With
LSZH
Covering
Without
LSZH
Covering
6.4
7.0
7.9
9.2
7.1
7.7
8.8
7.6
8.3
9.6
9.3
9.9
11.2
5.1
5.7
6.6
7.7
5.8
6.4
7.3
6.3
7.0
8.1
7.6
8.4
9.7
126
154
206
322
159
194
272
187
231
336
269
351
475
104
136
187
248
136
176
223
162
203
277
236
295
411
Cable Code
RF14028H-MICC-450/750V-1G6
RF14028H-MICC-450/750V-1G10
RF14028H-MICC-450/750V-1G16
RF14028H-MICC-450/750V-1G25
RF14028H-MICC-450/750V-1G35
RF14028H-MICC-450/750V-1G50
RF14028H-MICC-450/750V-1G70
RF14028H-MICC-450/750V-1G95
RF14028H-MICC-450/750V-1G120
RF14028H-MICC-450/750V-1G150
RF14028H-MICC-450/750V-1G185
RF14028H-MICC-450/750V-1G240
RF14028H-MICC-450/750V-1G300
RF14028H-MICC-450/750V-1G400
RF14028H-MICC-450/750V-2G1.5
RF14028H-MICC-450/750V-2G2.5
RF14028H-MICC-450/750V-2G4
RF14028H-MICC-450/750V-2G6
RF14028H-MICC-450/750V-2G10
RF14028H-MICC-450/750V-2G16
RF14028H-MICC-450/750V-2G25
8.0
9.0
12.0
15.0
18.0
22.0
27.0
32.0
37.0
44.0
54.0
70.0
79.0
91.0
11.0
13.0
16.0
18.0
24.0
30.0
38.0
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
Without
With
Without
With
LSZH
LSZH
LSZH
LSZH
Covering Covering Covering Covering
7.7
8.8
9.8
11.1
12.2
13.6
15.2
17.4
18.8
20.4
23.2
26.1
28.8
32.8
9.4
10.2
11.3
12.4
14.2
16.2
19.1
6.2
7.3
8.3
9.6
10.7
12.1
13.7
15.4
16.8
18.4
20.4
23.3
26.0
30.0
7.9
8.7
9.8
10.9
12.7
14.7
17.1
213
273
361
506
650
842
1147
1520
1870
2230
2575
3312
3972
5211
259
314
398
483
697
968
1275
173
240
326
457
585
758
1016
1324
1612
1949
2370
3050
3791
5004
237
276
355
446
619
850
1178
151
Cable Code
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
Without
With
Without
With
LSZH
LSZH
LSZH
LSZH
Covering Covering Covering Covering
RF14028H-MICC-450/750V-3G1.5
31.5
12.0
9.8
8.3
290
254
RF14028H-MICC-450/750V-3G2.5
32.5
14.0
10.8
9.3
365
323
RF14028H-MICC-450/750V-3G4
34.0
17.0
11.9
10.4
461
415
RF14028H-MICC-450/750V-3G6
36.0
20.0
13.0
11.5
590
526
RF14028H-MICC-450/750V-3G10
310.0
27.0
15.1
13.6
853
754
RF14028H-MICC-450/750V-3G16
316.0
34.0
17.1
15.6
1080
1034
RF14028H-MICC-450/750V-3G25
325.0
42.0
20.2
18.2
1548
1444
RF14028H-MICC-450/750V-4G1.5
41.5
14.0
10.6
9.1
344
305
RF14028H-MICC-450/750V-4G2.5
42.5
16.0
11.6
10.1
430
384
RF14028H-MICC-450/750V-4G4
44.0
20.0
12.9
11.4
577
507
RF14028H-MICC-450/750V-4G6
46.0
24.0
14.2
12.7
718
644
RF14028H-MICC-450/750V-4G10
410.0
30.0
16.3
14.8
1050
911
RF14028H-MICC-450/750V-4G16
416.0
39.0
19.3
17.3
1390
1286
RF14028H-MICC-450/750V-4G25
425.0
49.0
22.3
20.1
1943
1805
RF14028H-MICC-450/750V-7G1.5
71.5
18.0
12.3
10.8
478
432
RF14028H-MICC-450/750V-7G2.5
72.5
22.0
13.6
12.1
614
559
RF14028H-MICC-450/750V-12G1.5
121.5
28.0
15.8
14.1
772
712
RF14028H-MICC-450/750V-12G2.5
122.5
34.0
17.9
15.6
970
911
RF14028H-MICC-450/750V-19G1.5
191.5
37.0
18.9
16.6
1086
992
FE
e
Impact Resistant
152
Highly Flexible
Oil Resistant
Weather Resistant
Laid In Ducts
www.addison-cables.com
Standards
SE260
UNE 21123
Construction
Conductors: Stranded plain copper conductors to IEC
60228 class 2 or 5.
Insulation: FRPVC.
Outer sheath: FRPVC.
Optional
FRPVC/LSZH Sheath
FRPVC/LSZH Insulation
Limited re hazard pigtail rail connection cables: Stranded tinned copper conductors, LSZH composite insulation.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
0.6
1.15/1.16*
0.6/1.0
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Nominal
Insulation
Thickness
mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
RF260-VV-K-0.6/1KV-1G16
RF260-RZ1-K-0.6/1KV-1G16
116
116
19/1.04
19/1.04
0.7
0.7
1.4
1.4
10.3
10.3
249
255
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
153
Standards
SE774
UNE 21027
Construction
LSZH Insulation
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
1.0
18.2
4.0
4.7
6.0
3.11
0.45/0.75
16.0
1.16
35.0
0.529
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.0
14.0
16.0
116.0
135.0
1/1.13
7/0.85
7/1.04
7/1.7
19/1.53
0.6
0.8
0.8
1.0
1.2
4.0
5.5
6.1
8.1
10.9
28
33
90
197
389
RF774-ES07Z-U-450/750V-1G1
RF774-ES07Z-U-450/750V-1G4
RF774-ES07Z-U-450/750V-1G6
RF774-ES07Z-U-450/750V-1G16
RF774-ES07Z-U-450/750V-1G35
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
154
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
SE895
UNE 21027
LSZH Insulation
Construction
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
4.0
4.7
0.3/0.5
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
RF895-ES05Z-U-300/500V-1G4
14.0
7/0.85
0.8
6.8
85
Zero
Mineral Oil
Resistant
Flame Retardant
Fire Retardant
NF C32-070-2.1(C2)
NF C32-070-2.2(C1)
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
Zero Halogen
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
155
Standards
SE902
UNE 21123
Construction
XLPE Insulation
Insulation: XLPE.
LSZH Sheath
Sheath: LSZH.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
4.0
4.7
0.6/0.1
RF902-RZ1-U-0.6/1KV-1G4
14.0
Nominal
Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
0.8
21.6
624
7/0.85
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
156
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
SE1047
UNE 21031
Tinned Copper Conductor
PVC Insulation
Tinned Copper Wire Screen
Construction
Conductors: Stranded tinned copper conductors.
PVC Sheath
PVC Sheath
Insulation: PVC.
Screen: TCW (Tinned Copper Wire) screen.
Inner Sheath: PVC.
Outer Sheath: PVC.
Optional
Limited re hazard concentric signalling cables: Stranded tinned copper conductors, XLPE insulation, TCW screen,
PE sheath, units laid up, LFH sheath. (SE 1047 Type 2)
Concentric signalling screened cables: Stranded tinned copper conductors, PVC insulation, TCW spiral screen, PVC
sheath, TCWB, units laid up, PVC sheath. (SE 1047 Type 3)
Limited fire hazard concentric signalling screened cables: Stranded tinned copper conductors, XLPE insulation,
TCW spiral screen, PE sheath, TCWB, units laid up, LFH sheath. (SE 1047 Type 4)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Maximum DC Screen Resistance
mm
/km
/km
1.85
11
9.66
157
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.85
31.85
71.85
191.85
1/1.53
1/1.53
1/1.53
1/1.53
0.7
0.7
0.7
0.7
10.9
18.4
23.9
36.8
173
453
771
1815
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.85
31.85
71.85
191.85
1/1.53
1/1.53
1/1.53
1/1.53
0.7
0.7
0.7
0.7
10.3
17.1
22.1
33.8
140
361
612
1429
No. of units&
Nominal Conductor
Cross Sectional Area
No.mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.85
31.85
71.85
191.85
1/1.53
1/1.53
1/1.53
1/1.53
0.8
0.8
0.8
0.8
11.6
19.9
25.9
40.2
210
561
987
2375
No. of units&
Nominal Conductor
Cross Sectional Area
No.mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
RF1047-RC4Z1C4Z1-450/750V-1G1.85
RF1047-RC4Z1C4Z1-450/750V-3G1.85
RF1047-RC4Z1C4Z1-450/750V-7G1.85
RF1047-RC4Z1C4Z1-450/750V-19G1.85
11.85
31.85
71.85
191.85
1/1.53
1/1.53
1/1.53
1/1.53
0.8
0.8
0.8
0.8
11.0
18.6
24.1
37.2
184
487
875
2120
PVC Sheath
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
158
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
BR880
BS 5467
BS 6346
UNE 21123
Construction
XLPE/PVC Insulation
PETP Tape
PVC/LSZH Sheath
type TI 1 to BS 7655.
Core Wrapping: PETP (Polyethylene
Terephthalate).
Sheath: PVC type 9 to BS 7655 (LSZH can be offered as an option).
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
16
1.91*
25
1.2*
35
50
0.868*
0.641
0.6/1.0
70
0.443
95
0.32**
Core Identification
2 core: Brown/Blue
4 core: Blue/Brown/Black/Grey
159
Nominal
Thickness of
Insulation
mm
Nominal
Thickness of
Sheath
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
RF880-RV-K-0.6/1KV-2G16AL
RF880-RV-K-0.6/1KV-2G25AL
RF880-RV-K-0.6/1KV-2G35AL
RF880-RV-K-0.6/1KV-2G50AL
RF880-RV-K-0.6/1KV-2G70AL
RF880-RV-K-0.6/1KV-2G95AL
RF880-RV-K-0.6/1KV-4G70AL
RF880-RV-K-0.6/1KV-4G95AL
216
225
235
250
270
295
470
495
1.0
1.2
1.2
1.4
1.4
1.6
1.4
1.6
1.8
1.8
1.8
1.8
1.9
2.0
2.0
2.2
14.3
16.6
18.0
20.4
22.8
26.2
30.6
35.5
420
455
525
620
840
1020
1750
2100
PVC Sheath
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
160
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
NR/SP/ELP/40045 (formerly RT/E/PS/40045)
BS 7919
UNE 21027
Construction
PCP Sheath
EPR Insulation
to BS 6360.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
1.5
13.7
2.5
8.21
4.0
5.09
6.0
3.39
0.3/0.5
Core identification
4core
8core
161
Nominal
Thickness of
Insulation
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
41.5
42.5
44.0
81.5
82.5
84.0
86.0
810.0
816.0
30/0.25
50/0.25
56/0.30
30/0.25
50/0.25
56/0.25
84/0.30
75/0.40
118/0.40
0.8
0.9
1.0
0.8
0.9
1.0
1.0
1.2
1.2
14.3
16.5
18.5
18.5
21.4
23.6
25.6
31.7
36.2
220
390
420
460
510
830
1040
1799
2480
RF40045-H05RNF-300/500V-4G1.5
RF40045-H05RNF-300/500V-4G2.5
RF40045-H05RNF-300/500V-4G4
RF40045-H05RNF-300/500V-8G1.5
RF40045-H05RNF-300/500V-8G2.5
RF40045-H05RNF-300/500V-8G4
RF40045-H05RNF-300/500V-8G6
RF40045-H05RNF-300/500V-8G10
RF40045-H05RNF-300/500V-8G16
e
Impact Resistant
162
Highly Flexible
Oil Resistant
Weather Resistant
Laid In Ducts
www.addison-cables.com
Standard
NR/PS/TEL/31102(BR1817)
BS 6485
Construction
PVC/LSZH Sheath
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
150
250
/km
0.1825
0.1083
PVC Sheath
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
No. of cores&
No. & Nominal
Nominal Conductor
Diameter of Strands
Cross Sectional Area
No/mm
No.mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
RF31102-H07V-U-450/750V-1G150AL
1150
19/3.25
1.6
19.45
629
RF31102-H07V-U-450/750V-1G250AL
1250
19/4.22
1.6
24.30
995
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
163
NSGAFOU Cables
Applications
The cables are designed for use in switch cabinets, wiring of devices, trains
and buses as well as in dry rooms.
Standards
DIN VDE 0250-602
Construction
EPR Insulation
PCP Sheath
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
1.5
2.5
4.0
6.0
10
16
25
35
Conductor Resistance
/km
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
Current Rating
31
41
58
75
103
145
194
240
Voltage Rating
KV
1.8/3
mm
50
70
95
120
150
185
240
Conductor Resistance
/km
0.393
0.277
0.21
0.164
0.132
0.109
0.0817
Current Rating
301
372
456
528
607
639
821
Voltage Rating
KV
1.8/3
164
www.addison-cables.com
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
RF602-NSGAFOU-1G1.5
11.5
30/0.25
1.3
6.5
59
RF602-NSGAFOU-1G2.5
12.5
50/0.25
1.3
6.8
74
RF602-NSGAFOU-1G4
14.0
56/0.3
1.3
7.7
94
RF602-NSGAFOU-1G6
16.0
84/0.3
1.3
8.3
118
RF602-NSGAFOU-1G10
110.0
80/0.4
1.5
9.2
163
RF602-NSGAFOU-1G16
116.0
126/0.4
1.5
10.1
220
RF602-NSGAFOU-1G25
125.0
196/0.40
1.8
12.5
336
RF602-NSGAFOU-1G35
135.0
276/0.40
1.8
14.0
470
RF602-NSGAFOU-1G50
150.0
396/0.40
1.8
15.5
581
RF602-NSGAFOU-1G70
170.0
360/0.50
1.8
17.0
772
RF602-NSGAFOU-1G95
195.0
475/0.50
2.2
19.5
1030
RF602-NSGAFOU-1G120
1120.0
608/0.50
2.2
21.2
1280
RF602-NSGAFOU-1G150
1150.0
756/0.50
2.2
23.5
1650
RF602-NSGAFOU-1G185
1185.0
925/0.50
2.4
25.6
2050
RF602-NSGAFOU-1G240
1240.0
1221/0.50
2.6
27.3
2590
e
Impact Resistant
Highly Flexible
Oil Resistant
Weather Resistant
Laid In Ducts
165
Standard
NR/PS/ELP/00008(formerly RT/E/PS/00008)
BS 6622, BS 6234, BS 7454
IEC 60502-2, IEC60840
MDPE Sheath
Water Swellable Tape
Solid Aluminium/Stranded Copper Conductor
Semi-conducting Conductor Screen
XLPE Insulation
Semi-conducting Insulation Screen
Water Swellable Tape
Copper Wire Screen Wound With Copper Tape
Construction
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Capacitance
Voltage Rating
185
0.164
0.205
19/33
300
0.0601
0.243
19/33
Laid In Ducts
Buried in Ciround
Zero Halogen
166
www.addison-cables.com
0.9
0.9
8.0/0.6
8.0/0.6
45.0
50.0
2200
4500
Standard
BS 7835
BS EN 50267-2-1
Semi-conducting Conductor Screen
Stranded Copper Conductor
XLPE Insulation
Semi-conducting Insulation Screen
Copper Tape Screen
Construction
Conductor: Class 2 stranded plain copper conductor to BS EN 60228: 2005 (previously BS 6360).
Conductor Screen: Semi-conducting material.
Insulation: XLPE Type GP8 to BS 7655.
Insulation Screen: Semi-conducting material.
Metallic Screen: Individual and overall copper tape screen.
Filler: PETP (Polyethylene Terephthalate) bres.
Separator: Binding tape.
Bedding: LSZH.
Armour: Aluminium wire armoured (AWA) (for single core cables) or steel wire armoured (SWA) (for multicore
cables).
Sheath: LSZH.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
mm
/km
KV
50
0.387
300
0.0601
70
0.268
400
0.047
95
0.193
120
0.153
11
500
0.0366
150
0.124
630
0.0283
185
0.0991
800
0.0221
240
0.0754
1000
0.0176
11
167
Cable Code
RF7835-RHZ1MZ1-6.35/11KV-1G50CU
RF7835-RHZ1MZ1-6.35/11KV-1G70CU
RF7835-RHZ1MZ1-6.35/11KV-1G95CU
RF7835-RHZ1MZ1-6.35/11KV-1G120CU
RF7835-RHZ1MZ1-6.35/11KV-1G150CU
RF7835-RHZ1MZ1-6.35/11KV-1G185CU
RF7835-RHZ1MZ1-6.35/11KV-1G240CU
RF7835-RHZ1MZ1-6.35/11KV-1G300CU
RF7835-RHZ1MZ1-6.35/11KV-1G400CU
RF7835-RHZ1MZ1-6.35/11KV-1G500CU
RF7835-RHZ1MZ1-6.35/11KV-1G630CU
RF7835-RHZ1MZ1-6.35/11KV-1G800CU
RF7835-RHZ1MZ1-6.35/11KV-1G1000CU
RF7835-RHZ1MZ1-6.35/11KV-3G25CU
RF7835-RHZ1MZ1-6.35/11KV-3G35CU
RF7835-RHZ1MZ1-6.35/11KV-3G50CU
RF7835-RHZ1MZ1-6.35/11KV-3G70CU
RF7835-RHZ1MZ1-6.35/11KV-3G95CU
RF7835-RHZ1MZ1-6.35/11KV-3G120CU
RF7835-RHZ1MZ1-6.35/11KV-3G150CU
RF7835-RHZ1MZ1-6.35/11KV-3G185CU
RF7835-RHZ1MZ1-6.35/11KV-3G240CU
RF7835-RHZ1MZ1-6.35/11KV-3G300CU
RF7835-RHZ1MZ1-6.35/11KV-3G400CU
RF7835-RHZ1MZ1-6.35/11KV-1G50AL
RF7835-RHZ1MZ1-6.35/11KV-1G70AL
RF7835-RHZ1MZ1-6.35/11KV-1G95AL
RF7835-RHZ1MZ1-6.35/11KV-1G120AL
RF7835-RHZ1MZ1-6.35/11KV-1G150AL
RF7835-RHZ1MZ1-6.35/11KV-1G185AL
RF7835-RHZ1MZ1-6.35/11KV-1G240AL
RF7835-RHZ1MZ1-6.35/11KV-1G300AL
RF7835-RHZ1MZ1-6.35/11KV-1G400AL
RF7835-RHZ1MZ1-6.35/11KV-1G500AL
RF7835-RHZ1MZ1-6.35/11KV-1G630AL
RF7835-RHZ1MZ1-6.35/11KV-1G800AL
RF7835-RHZ1MZ1-6.35/11KV-1G1000AL
RF7835-RHZ1MZ1-6.35/11KV-3G50AL
RF7835-RHZ1MZ1-6.35/11KV-3G70AL
RF7835-RHZ1MZ1-6.35/11KV-3G95AL
RF7835-RHZ1MZ1-6.35/11KV-3G120AL
RF7835-RHZ1MZ1-6.35/11KV-3G150AL
RF7835-RHZ1MZ1-6.35/11KV-3G185AL
RF7835-RHZ1MZ1-6.35/11KV-3G240AL
RF7835-RHZ1MZ1-6.35/11KV-3G300AL
RF7835-RHZ1MZ1-6.35/11KV-3G400AL
Nominal
Insulation
Thickness
mm
Copper Conductor
150
170
195
1120
1150
1185
1240
1300
1400
1500
1630
1800
11000
325
335
350
370
395
3120
3150
3185
3240
3300
3400
Aluminium Conductor
150
170
195
1120
1150
1185
1240
1300
1400
1500
1630
1800
11000
350
370
395
3120
3150
3185
3240
3300
3400
Nominal Sheath
Thickness
mm/mm
Inner
Outer
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.3
1.4
1.5
1.6
1.3
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.0
1.8
1.9
1.9
2.0
2.1
2.1
2.2
2.2
2.4
2.5
2.6
2.7
2.9
2.4
2.5
2.6
2.7
2.8
3.0
3.1
3.2
3.4
3.6
3.8
28.5
30.0
31.7
33.9
35.7
37.5
40.0
43.0
45.8
50.5
54.8
59.2
64.3
48.8
51.6
54.6
58.5
62.6
66.6
69.8
74.1
81.2
87.0
95.0
1200
1500
1600
2100
2500
2900
3600
4300
5200
6500
8000
9850
12100
4300
4700
5300
6300
7300
8400
9600
11000
14000
16600
19500
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.3
1.4
1.5
1.6
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.0
1.8
1.9
1.9
2.0
2.1
2.1
2.2
2.2
2.4
2.5
2.6
2.7
2.9
2.6
2.7
2.8
3.0
3.1
3.2
3.4
3.6
3.8
39.3
41.0
42.9
44.5
47.3
49.3
51.7
54.4
57.7
61.1
65.0
71.6
76.5
78.2
82.1
86.1
90.0
93.2
97.5
103.3
108.8
116.1
1740
1850
2100
2250
2600
2850
3150
3600
4000
4500
5250
6150
7200
8300
9050
9800
10600
11350
12250
13700
15500
16750
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
168
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standard
CENELEC HD 620
C 33-226
Construction
Conductor: Class 2 stranded plain copper / aluminium conductor to BS EN 60228: 2005 (previously BS 6360).
Conductor Screen: Semi-conducting material.
Insulation: XLPE.
Insulation Screen: Semi-conducting
PE Sheath
Binding Tape
Stranded Copper/Aluminium Conductor
Semi-conducting Conductor Screen
XLPE Insulation
Semi-conducting Insulation Screen
Binding Tape
Copper Wire Screen
material.
Metallic Screen: Copper wire screen.
Filler: PETP (Polyethylene Terephthalate)
bres.
Separator: Binding tape.
Sheath: PE.
Optional
Armoured Cables: Galvanized steel at wire armoured cables can be offered as options.
Electrical Characteristics at 20
Copper Conductor
Nominal Conductor Cross Section
mm
25
50
95
150
/km
0.727
0.387
0.193
0.124
Voltage Rating
KV
240
300
0.0754 0.0601
400
0.047
500
630
0.0366 0.0283
20
Aluminium Conductor
Nominal Conductor Cross Section
mm
95
150
240
300
400
500
630
/km
0.32
0.206
0.125
0.1
0.0778
0.0605
0.0469
Voltage Rating
KV
20
169
Cable Code
Nominal
Insulation
Thickness
mm
Nominal
Nominal
Overall
Sheath
Thickness Diameter
mm
mm
Nominal
Weight
kg/km
RF33226-XKDT-12/20KV-1G25CU
125
7/2.14
5.5
1.8
27
740
RF33226-XKDT-12/20KV-1G50CU
150
19/1.78
5.5
2.0
29
1120
RF33226-XKDT-12/20KV-1G95CU
195
19/2.52
5.5
2.1
32
1640
RF33226-XKDT-12/20KV-1G150CU
1150
37/2.25
5.5
2.2
35
2320
RF33226-XKDT-12/20KV-1G240CU
1240
61/2.25
5.5
2.4
41
3360
RF33226-XKDT-12/20KV-1G300CU
1300
61/2.52
5.5
2.5
43
4060
RF33226-XKDT-12/20KV-1G400CU
1400
61/2.85
5.5
2.6
46
5040
RF33226-XKDT-12/20KV-1G500CU
1500
91/2.65
5.5
2.7
50
6150
RF33226-XKDT-12/20KV-1G630CU
1630
127/2.52
5.5
2.9
56
7830
Cable Code
No. &
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
RF33226-XKDT-YT-12/20KV-3G25CU
325
7/2.14
5.5
2.9
62
2740
RF33226-XKDT-YT-12/20KV-3G50CU
350
19/1.78
5.5
3.0
65
3750
RF33226-XKDT-YT-12/20KV-3G95CU
395
19/2.52
5.5
3.3
72
5330
RF33226-XKDT-YT-12/20KV-3G150CU
3150
37/2.25
5.5
3.5
79
7450
RF33226-XKDT-YT-12/20KV-3G240CU
3240
61/2.25
5.5
3.8
91
10670
RF33226-XKDT-YT-12/20KV-3G300CU
3300
61/2.52
5.5
4.0
98
13140
No. &
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Nominal
Overall
Sheath
Thickness Diameter
mm
mm
Nominal
Weight
kg/km
RF33226-XKDT-12/20KV-1G95AL
195
19/2.52
5.5
2.1
32
970
RF33226-XKDT-12/20KV-1G150AL
1150
37/2.25
5.5
2.2
35
1310
RF33226-XKDT-12/20KV-1G240AL
1240
61/2.25
5.5
2.4
40
1830
RF33226-XKDT-12/20KV-1G300AL
1300
61/2.52
5.5
2.5
44
2140
RF33226-XKDT-12/20KV-1G400AL
1400
61/2.85
5.5
2.6
47
2480
RF33226-XKDT-12/20KV-1G500AL
1500
61/3.20
5.5
2.7
51
2920
RF33226-XKDT-12/20KV-1G630AL
1630
127/2.52
5.5
2.9
56
3580
170
www.addison-cables.com
Cable Code
RF33226-XKDT-YT-12/20KV-3G95AL
RF33226-XKDT-YT-12/20KV-3G150AL
RF33226-XKDT-YT-12/20KV-3G240AL
RF33226-XKDT-YT-12/20KV-3G300AL
RF33226-XKDT-YT-12/20KV-3G400AL
395
3150
3240
3300
3400
19/2.52
37/2.25
61/2.25
61/2.52
61/2.85
5.5
5.5
5.5
5.5
5.5
3.3
3.5
3.8
4.0
4.3
72
79
90
98
106
3310
4360
6020
7000
8010
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
72.9
81.5
89.1
99.5
7470
10100
12800
16850
XKDT-FT Three Core 12/20KV Copper Conductor Galvanized Steel Flat Wire Armoured
No. &
No. of cores&
Nominal Conductor Nominal
Diameter
Cross Sectional
of Strands
Area
No/mm
No.mm
Cable Code
RF33226-XKDT-FT-12/20KV-3G50CU
RF33226-XKDT-FT-12/20KV-3G95CU
RF33226-XKDT-FT-12/20KV-3G150CU
RF33226-XKDT-FT-12/20KV-3G240CU
350
395
3150
3240
Nominal
Insulation
Thickness
mm
19/1.78
19/2.52
37/2.25
61/2.25
Nominal
Sheath
Thickness
mm
Inner Outer
5.5
5.5
5.5
5.5
1.6
1.7
1.8
2.0
3.0
3.3
3.5
3.8
Zero
UV Resistant
Water Resistant
Laid In Ducts
Buried in Ciround
Zero Halogen
171
Standard
BS 6622 (PVC)
BS 7835 (LSZH)
Construction
Conductor: Class 2 stranded plain copper conductor to BS EN 60228: 2005 (previously BS 6360).
Conductor Screen: Semi-conducting material.
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS 7655.
Insulation Screen: Semi-conducting material.
Metallic Screen: Individual and overall copper tape screen to BS 6622.
Filler: PETP (Polyethylene Terephthalate) bres.
Separator: Binding tape.
Bedding: PVC Type TM1 to BS 7655 or LSZH.
Armour: Aluminium wire armoured (AWA) (for single core cables) or steel wire armoured (SWA) (for multicore
cables).
Sheath: PVC Type TM1 to BS 7655 or LSZH.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
50
0.387
mm
/km
KV
300
0.0601
70
0.268
400
0.047
95
0.193
120
0.153
19/33
150
0.124
500
630
0.0366
0.0283
19/33
172
www.addison-cables.com
185
0.0991
800
0.0221
240
0.0754
1000
0.0176
Cable Code
Nominal
Insulation
Thickness
mm
Copper Conductor
170
8.0
195
8.0
1120
8.0
1150
8.0
1185
8.0
1240
8.0
1300
8.0
1400
8.0
1500
8.0
1630
8.0
1800
8.0
11000
8.0
350
8.0
370
8.0
395
8.0
3120
8.0
3150
8.0
3185
8.0
3240
8.0
3300
8.0
3400
8.0
Aluminium Conductor
170
8.0
195
8.0
1120
8.0
1150
8.0
1185
8.0
1240
8.0
1300
8.0
1400
8.0
1500
8.0
1630
8.0
1800
8.0
11000
8.0
350
8.0
370
8.0
395
8.0
3120
8.0
3150
8.0
3185
8.0
3240
8.0
3300
8.0
3400
8.0
RF6622-RHVMV-19/33KV-1G70CU
RF6622-RHVMV-19/33KV-1G95CU
RF6622-RHVMV-19/33KV-1G120CU
RF6622-RHVMV-19/33KV-1G150CU
RF6622-RHVMV-19/33KV-1G185CU
RF6622-RHVMV-19/33KV-1G240CU
RF6622-RHVMV-19/33KV-1G300CU
RF6622-RHVMV-19/33KV-1G400CU
RF6622-RHVMV-19/33KV-1G500CU
RF6622-RHVMV-19/33KV-1G630CU
RF6622-RHVMV-19/33KV-1G800CU
RF6622-RHVMV-19/33KV-1G1000CU
RF6622-RHVMV-19/33KV-3G50CU
RF6622-RHVMV-19/33KV-3G70CU
RF6622-RHVMV-19/33KV-3G95CU
RF6622-RHVMV-19/33KV-3G120CU
RF6622-RHVMV-19/33KV-3G150CU
RF6622-RHVMV-19/33KV-3G185CU
RF6622-RHVMV-19/33KV-3G240CU
RF6622-RHVMV-19/33KV-3G300CU
RF6622-RHVMV-19/33KV-3G400CU
RF6622-RHVMV-19/33KV-1G70AL
RF6622-RHVMV-19/33KV-1G95AL
RF6622-RHVMV-19/33KV-1G120AL
RF6622-RHVMV-19/33KV-1G150AL
RF6622-RHVMV-19/33KV-1G185AL
RF6622-RHVMV-19/33KV-1G240AL
RF6622-RHVMV-19/33KV-1G300AL
RF6622-RHVMV-19/33KV-1G400AL
RF6622-RHVMV-19/33KV-1G500AL
RF6622-RHVMV-19/33KV-1G630AL
RF6622-RHVMV-19/33KV-1G800AL
RF6622-RHVMV-19/33KV-1G1000AL
RF6622-RHVMV-19/33KV-3G50AL
RF6622-RHVMV-19/33KV-3G70AL
RF6622-RHVMV-19/33KV-3G95AL
RF6622-RHVMV-19/33KV-3G120AL
RF6622-RHVMV-19/33KV-3G150AL
RF6622-RHVMV-19/33KV-3G185AL
RF6622-RHVMV-19/33KV-3G240AL
RF6622-RHVMV-19/33KV-3G300AL
RF6622-RHVMV-19/33KV-3G400AL
Nominal Sheath
Thickness
mm
Inner
Outer
Nominal
Overall
Diameter
mm
1.2
1.2
1.2
1.3
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.2
2.3
2.3
2.4
2.5
2.5
2.6
2.7
2.8
2.9
3.0
3.2
3.4
3.5
3.6
3.7
3.8
3.9
4.1
4.3
4.5
41.0
42.9
44.5
47.3
49.3
51.7
54.4
57.7
61.1
65.0
71.6
76.5
78.2
82.1
86.1
90.0
93.2
97.5
103.3
108.8
116.1
2300
2650
3000
3500
4000
4650
5450
6350
7600
9150
11100
13400
9150
10300
11600
12800
14050
15650
18200
21100
24200
1.2
1.2
1.2
1.3
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.2
2.3
2.3
2.4
2.5
2.5
2.6
2.7
2.8
2.9
3.0
3.2
3.4
3.5
3.6
3.7
3.8
3.9
4.1
4.3
4.5
41.0
42.9
44.5
47.3
49.3
51.7
54.4
57.7
61.1
65.0
71.6
76.5
78.2
82.1
86.1
90.0
93.2
97.5
103.3
108.8
116.1
1850
2100
2250
2600
2850
3150
3600
4000
4500
5250
6150
7200
8300
9050
9800
10600
11350
12250
13700
15500
16750
Nominal
Weight
kg/km
PVC Sheath
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Zero
LSZH Sheath
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
173
Standard
IEC60092
BS 7655
IEC60502
BS 6883 Type 657 SW4
Construction
Stranded Annealed Copper Conductor
PETP
BS 6360).
EPR Insulation
C o r e Wr a p p i n g : P E T P ( P o l y e t h y l e n e
Terephthalate).
Insulation: EPR, GP8 to BS 6899 / BS 7655 RS2 / ICEA S-95-658.
Sheath: Thermosetting LSZH compound SW4 or LRS1 to BS 7655 / ICEA T-33-655, with enhanced oil resistance,
and minimum tear resistance.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Minimum Insulation Resistance
mm
70
95
120
150
185
240
300
400
500
/km
0.277
0.21
0.164
0.132
0.108
0.0817
0.0654
0.0495
0.0391
M.km
539
472
433
390
355
313
280
245
221
330
400
464
530
612
648
853
1010
1195
kA
10.0
13.5
17.1
21.4
26.4
34.3
42.9
57.2
71.5
Voltage Rating
KV
1.8
174
www.addison-cables.com
No. of cores&
Nominal
Conductor Cross
Sectional Area
No.mm
No. &
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
Polarity
RF6883-DZ1-U-1800P-1G70
RF6883-DZ1-U-1800P-1G95
RF6883-DZ1-U-1800P-1G120
RF6883-DZ1-U-1800P-1G150
RF6883-DZ1-U-1800P-1G185
RF6883-DZ1-U-1800P-1G240
RF6883-DZ1-U-1800P-1G300
RF6883-DZ1-U-1800P-1G400
RF6883-DZ1-U-1800P-1G500
RF6883-DZ1-U-1800P-1G630
RF6883-DZ1-U-1800P-1G800
170
195
1120
1150
1185
1240
1300
1400
1500
1630
1800
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
91/2.65
127/2.52
127/2.85
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
2.0
2.0
2.2
2.2
2.3
2.3
2.4
2.4
2.5
2.5
2.7
20.3
21.7
23.6
19.3
27.3
30.7
33.3
40.3
42.3
43.4
50.6
1371
1641
1958
2295
2682
3341
4016
5071
6275
6980
8785
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
175
Standard
IEC60092
BS 7655
IEC60502
BS 6883 Type 657 SW4
Construction
PETP Tape
BS 6360).
C o r e Wr a p p i n g : P E T P ( P o l y e t h y l e n e
Terephthalate).
Sheath: Thermosetting LSZH compound SW4 or LRS1 to BS 7655 / ICEA T-33-655 with enhanced oil resistance,
and minimum tear resistance.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Minimum Insulation Resistance
Conductor Short Circuit Current 1s
Voltage Rating
mm
70
95
120
150
185
240
300
400
500
/km
0.277
0.21
0.164
0.132
0.108
0.0817
0.0654
0.0495
0.0391
M.km
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
kA
10.0
13.5
17.1
21.4
26.4
34.3
42.9
57.2
71.5
KV
0.3
176
www.addison-cables.com
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
Polarity
RF6883-ES05Z1-U-300N-1G70
RF6883-ES05Z1-U-300N-1G95
RF6883-ES05Z1-U-300N-1G120
RF6883-ES05Z1-U-300N-1G150
RF6883-ES05Z1-U-300N-1G185
RF6883-ES05Z1-U-300N-1G240
RF6883-ES05Z1-U-300N-1G300
RF6883-ES05Z1-U-300N-1G400
RF6883-ES05Z1-U-300N-1G500
RF6883-ES05Z1-U-300N-1G630
RF6883-ES05Z1-U-300N-1G800
170
195
1120
1150
1185
1240
1300
1400
1500
1630
1800
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
91/2.65
127/2.52
127/2.85
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
19.4
20.7
22.6
24.3
26.3
29.1
32.3
36.3
40.3
42.3
46.5
1055
1307
1598
1913
2274
2893
3530
4532
5684
6400
8094
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Zero
Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
177
178
www.addison-cables.com
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Stranded Plain/Tinned
Copper Conductor
Optional
FRA-SW-0.75S (Sheathed); FRA-SW-0.75S-OS (Screened & sheathed)
FRA-SW-0.75SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
1.0
20
1.5
13.7
2.5
8.21
4.0
5.09
0.45/0.75
6.0
3.39
10
1.95
16
1.24
32/0.2
30/0.25
50/0.25
56/0.3
84/0.3
80/0.4
126/0.4
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
Low Corrosivity
Low Toxicity
0.8
0.8
0.8
0.8
0.9
0.9
1.1
3.9
4.2
4.6
5.2
6.4
7.5
8.6
28
34
41
64
93
141
203
Zero
e
Weather Resistant
Nominal Diameter
of Strands
mm
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
179
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Stranded Plain/Tinned Copper Conductor
/ BS 6360.
Insulation: Electron beam crosslinkable
Optional
FRA-SW-0.75M-OS (Screened)
FRA-SW-0.75M-FR (Fire resistant)
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
1.0
1.5
2.5
4.0
6.0
10
16
/km
20
13.7
8.21
5.09
3.39
1.95
1.24
Voltage Rating
KV
180
www.addison-cables.com
0.45/0.75
Nominal Diameter of
Strands
mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
21.5
31.5
41.5
51.5
71.5
131.5
191.5
281.5
371.5
22.5
32.5
42.5
52.5
72.5
132.5
192.5
282.5
372.5
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
8.9
9.6
10.6
11.6
12.5
17.0
19.3
23.6
26.6
10.3
11.1
12.3
13.4
14.6
20.0
22.8
28.2
31.7
127
144
177
186
243
411
586
901
1068
166
201
252
282
345
616
806
1236
1650
FRA-SW-0.75M-2G1.5
FRA-SW-0.75M-3G1.5
FRA-SW-0.75M-4G1.5
FRA-SW-0.75M-5G1.5
FRA-SW-0.75M-7G1.5
FRA-SW-0.75M-13G1.5
FRA-SW-0.75M-19G1.5
FRA-SW-0.75M-28G1.5
FRA-SW-0.75M-37G1.5
FRA-SW-0.75M-2G2.5
FRA-SW-0.75M-3G2.5
FRA-SW-0.75M-4G2.5
FRA-SW-0.75M-5G2.5
FRA-SW-0.75M-7G2.5
FRA-SW-0.75M-13G2.5
FRA-SW-0.75M-19G2.5
FRA-SW-0.75M-28G2.5
FRA-SW-0.75M-37G2.5
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
181
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Optional
FRA-TW-0.75S (Sheathed)
FRA-TW-0.75SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
AWG
/km
KV
20
28.3
18
17.9
182
www.addison-cables.com
16
14
14.1
8.3
0.45/0.75
12
6.8
10
3.6
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
19/0.2
19/0.25
19/0.3
37/0.25
37/0.3
37/0.4
0.18
0.18
0.18
0.22
0.28
0.34
1.5
1.75
2.0
2.35
2.77
3.45
7
10
14
19
28
47
Nominal Diameter
No. of cores& Nominal
of Strands
Conductor Cross Sectional Area
No/mm
No. x AWG
Cable Code
FRA-TW-0.75SU-1C20A
FRA-TW-0.75SU-1C18A
FRA-TW-0.75SU-1C16A
FRA-TW-0.75SU-1C14A
FRA-TW-0.75SU-1C12A
FRA-TW-0.75SU-1C10A
1 x 20
1 x 18
1 x 16
1 x 14
1 x 12
1 x 10
Nominal Diameter
of Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
FRA-TW-0.75S-OS-1C20A
FRA-TW-0.75S-OS-1C18A
FRA-TW-0.75S-OS-1C16A
1 x 20
1 x 18
1 x 16
19/0.2
19/0.25
19/0.3
0.18
0.18
0.18
2.5
2.7
2.9
17
19.4
24.2
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
183
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
/ BS 6360
Electron Beam Crosslinkable LSZH Sheath
Optional
FRA-TW-0.75M-OS (Screened)
FRA-TW-0.75M-FR (Fire resistant)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
AWG
/km
KV
20
28.3
18
17.9
184
www.addison-cables.com
16
14
14.1
8.3
0.45/0.75
12
6.8
10
3.6
Cable Code
FRA-TW-0.75M-2C20A
FRA-TW-0.75M-2C18A
FRA-TW-0.75M-2C16A
FRA-TW-0.75M-2C14A
FRA-TW-0.75M-2C12A
FRA-TW-0.75M-3C20A
FRA-TW-0.75M-3C18A
FRA-TW-0.75M-4C20A
FRA-TW-0.75M-4C18A
FRA-TW-0.75M-4C16A
220
218
216
214
212
320
318
420
418
416
19/0.2
19/0.25
19/0.3
37/0.25
37/0.3
19/0.2
19/0.25
19/0.2
19/0.25
19/0.3
0.18
0.18
0.18
0.22
0.28
0.18
0.18
0.18
0.18
0.18
4.2
4.6
5.3
6.1
7.3
4.4
4.95
4.65
5.2
6.0
Nominal Weight
kg/km
32
39
54
66
92
46
62
59
80
104
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
185
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Conductors: Circular Class 5 stranded
Optional
FRA-MW-1S (Sheathed); FRA-MW-1S-OS (Screened & Sheathed)
FRA-MW-1SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
0.5
40.1
0.75
26.7
1.0
20.0
1.5
13.7
0.6/1.0
2.5
8.21
4.0
5.09
6.0
3.39
mm
/km
KV
10
1.95
16
1.24
25
0.795
35
0.565
0.6/1.0
50
0.393
70
0.277
95
0.21
mm
/km
KV
120
0.164
150
0.132
186
www.addison-cables.com
185
240
0.108
0.0817
0.6/1.0
300
0.0654
400
0.0495
Cable Code
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
6
FRA-MW-1SU-1G0.5
10.5
16/0.2
0.6
2.0
FRA-MW-1SU-1G0.75
10.75
24/0.2
0.6
2.2
FRA-MW-1SU-1G1
11.0
32/0.2
0.6
2.6
10
FRA-MW-1SU-1G1.5
11.5
30/0.25
0.7
3.1
20
FRA-MW-1SU-1G2.5
12.5
50/0.25
0.7
3.5
30
FRA-MW-1SU-1G4
14.0
56/0.3
0.7
4.1
50
FRA-MW-1SU-1G6
16.0
84/0.3
0.7
4.6
60
FRA-MW-1SU-1G10
110
80/0.4
0.7
5.5
110
FRA-MW-1SU-1G16
116
126/0.4
0.7
6.7
160
FRA-MW-1SU-1G25
125
196/0.40
0.9
8.5
240
FRA-MW-1SU-1G35
135
276/0.40
0.9
9.8
330
FRA-MW-1SU-1G50
150
396/0.40
1.0
11.5
460
FRA-MW-1SU-1G70
170
360/0.50
1.0
13.6
660
FRA-MW-1SU-1G95
195
475/0.50
1.1
15.1
860
FRA-MW-1SU-1G120
1120
608/0.50
1.1
17.1
1080
FRA-MW-1SU-1G150
1150
756/0.50
1.4
19.1
1370
FRA-MW-1SU-1G185
1185
925/0.50
1.6
21.3
1690
FRA-MW-1SU-1G240
1240
1221/0.50
1.7
24.1
2230
FRA-MW-1SU-1G300
1300
1525/0.50
1.8
26.7
2780
FRA-MW-1SU-1G400
1400
2013/0.50
2.0
30.5
3740
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
187
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Stranded Plain/Tinned Copper Conductor
/ BS 6360.
Optional
FRA-MW-1M-FR (Fire resistant)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
mm
/km
KV
0.5
40.1
0.75
26.7
10
1.95
188
www.addison-cables.com
1.0
20.0
16
1.24
1.5
13.7
0.6/1.0
25
0.795
0.6/1.0
2.5
8.21
35
0.565
4.0
5.09
6.0
3.39
50
0.393
Nominal Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
20.5
40.5
70.5
180.5
30.75
50.75
80.75
120.75
200.75
21.0
61.0
91.0
251.0
21.5
31.5
51.5
*7G 1.5
121.5
361.5
16/0.20
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
5.9
7.0
9.1
12.7
6.8
8.4
10.9
11.9
15.2
6.9
10.0
12.5
18.7
7.5
8.0
10.2
12.1
14.2
23
48
55
72
86
70
107
147
175
350
72
160
210
519
86
90
169
238
313
905
*Gyellow/green
Nominal Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
FRA-MW-1M-OS-2G0.5
FRA-MW-1M-OS-4G0.5
FRA-MW-1M-OS-7G0.5
FRA-MW-1M-OS-15G0.5
FRA-MW-1M-OS-9P0.5S
FRA-MW-1M-OS-3G0.75
FRA-MW-1M-OS-6G0.75
FRA-MW-1M-OS-9G0.75
FRA-MW-1M-OS-16G0.75
FRA-MW-1M-OS-5P0.75S
FRA-MW-1M-OS-4G1
FRA-MW-1M-OS-7G1
FRA-MW-1M-OS-3G1.5
FRA-MW-1M-OS-5G1.5
FRA-MW-1M-OS-9G1.5
FRA-MW-1M-OS-16G1.5
FRA-MW-1M-OS-6P1.5S
FRA-MW-1M-OS-2G2.5
FRA-MW-1M-OS-4G2.5
FRA-MW-1M-OS-7G2.5
FRA-MW-1M-OS-3G4
FRA-MW-1M-OS-5G4
FRA-MW-1M-OS-3G6
FRA-MW-1M-OS-5G6
FRA-MW-1M-OS-3G10
20.5
40.5
70.5
150.5
920.5
30.75
60.75
90.75
160.75
520.75
41.0
71.0
31.5
51.5
91.5
161.5
621.5
22.5
42.5
72.5
34
54
36
56
310
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.25
32/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
84/0.30
84/0.30
80/0.40
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
6.6
7.5
9.8
13.4
20.6
7.5
9.9
12.3
14.4
16.0
8.8
11.8
8.6
10.9
14.9
17.5
18.9
9.6
11.3
14.8
11.8
14.7
13.8
17.4
17.1
68
102
145
240
541
94
165
243
348
354
140
226
124
208
409
560
540
160
222
400
260
440
370
620
580
189
Cable Code
Nominal Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
410
510
316
225
335
635
250
80/0.40
80/0.40
126/0.40
196/0.40
276/0.40
276/0.40
396/0.40
0.7
0.7
0.7
0.9
0.9
0.9
1.0
19.2
21.1
20.5
22.9
27.9
39.7
29.8
750
850
820
990
1600
3390
1760
FRA-MW-1M-OS-4G10
FRA-MW-1M-OS-5G10
FRA-MW-1M-OS-3G16
FRA-MW-1M-OS-2G25
FRA-MW-1M-OS-3G35
FRA-MW-1M-OS-6G35
FRA-MW-1M-OS-2G50
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
190
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Conductors: Circular Class 5 stranded
Optional
FRA-TW-1SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
0.5
0.6
0.75
1.0
/km
40.1
33.4
26.7
20
Voltage Rating
KV
1.2
1.5
2.0
2.5
4.0
16.3
13.7
11.2
8.21
5.09
0.6/1.0
191
Cable Code
FRA-TW-1SU-1C0.5S
FRA-TW-1SU-1C0.6S
FRA-TW-1SU-1C0.75S
FRA-TW-1SU-1C1S
FRA-TW-1SU-1C1.2S
FRA-TW-1SU-1C1.5S
FRA-TW-1SU-1C2S
FRA-TW-1SU-1C2.5S
FRA-TW-1SU-1C4S
10.5
10.6
10.75
11.0
11.2
11.5
12.0
12.5
14.0
19/0.18
19/0.20
19/0.22
19/0.26
19/0.28
19/0.30
37/0.25
19/0.40
56/0.30
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal
Weight
kg/km
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
1.4
1.5
1.6
1.75
2.0
2.15
2.4
2.75
3.35
5.8
7
8.4
10
13
16
19
26
40
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
192
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
/ BS 6360.
Optional
FRA-TW-1M-FR (Fire resistant)
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
0.5
0.75
1.0
1.5
2.5
/km
40.1
26.7
20
13.7
8.21
Voltage Rating
KV
0.6/1.0
193
No. of cores&
Nominal Conductor
Cross Sectional Area
No.mm
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
FRA-TW-1M-2C0.5S
FRA-TW-1M-3C0.5S
FRA-TW-1M-4C0.5S
FRA-TW-1M-5C0.5S
FRA-TW-1M-6C0.5S
FRA-TW-1M-2P0.5S
FRA-TW-1M-4P0.5S
FRA-TW-1M-2C0.75S
FRA-TW-1M-3C0.75S
FRA-TW-1M-4C0.75S
FRA-TW-1M-6C0.75S
FRA-TW-1M-2P0.75S
FRA-TW-1M-2C1S
FRA-TW-1M-3C1S
FRA-TW-1M-4C1S
FRA-TW-1M-6C1S
FRA-TW-1M-10C1S
FRA-TW-1M-25C1S
FRA-TW-1M-2C1.5S
FRA-TW-1M-3C1.5S
FRA-TW-1M-4C1.5S
FRA-TW-1M-5C1.5S
FRA-TW-1M-6C1.5S
FRA-TW-1M-7C1.5S(G/Y)
FRA-TW-1M-8C1.5S
FRA-TW-1M-10C1.5S
FRA-TW-1M-18C1.5S
FRA-TW-1M-25C1.5S(G/Y)
FRA-TW-1M-2C2.5S
FRA-TW-1M-3C2.5S
FRA-TW-1M-4C2.5S
FRA-TW-1M-5C2.5S
FRA-TW-1M-6C2.5S
20.5
30.5
40.5
50.5
60.5
220.5
420.5
20.75
30.75
40.75
60.75
220.75
21.0
31.0
41.0
61.0
101.0
251.0
21.5
31.5*
41.5
51.5*
61.5
7G 1.5
81.5
101.5
181.5
25G 1.5
22.5
32.5*
42.5
52.5
62.5
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.3
19/0.3
19/0.3
19/0.3
19/0.3
19/0.3
19/0.3
19/0.3
19/0.3
19/0.3
19/0.4
19/0.4
19/0.4
19/0.4
19/0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
4.4
4.6
5.0
5.5
6.0
6.5
8.7
4.75
5.15
5.6
6.75
7.75
5.1
5.4
5.8
7.3
8.7
12.8
6.0
6.3
6.9
7.8
8.45
9.1
10.3
10.6
13.4
15.5
7.3
7.8
8.7
9.4
10.6
31
36
43
53
62
58
99
35
47
57
83
81
45
54
64
98
143
324
63
76
94
116
141
165
201
216
374
494
98
122
152
181
223
194
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal Weight
kg/km
20.5
30.5
40.5
60.5
150.5
220.5
320.5
420.5
1220.5
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
4.8
5.3
5.4
6.5
9.0
7.2
8.1
9.3
13.0
42
51
56
82
167
80
98
131
276
www.addison-cables.com
Cable Code
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal Weight
kg/km
FRA-TW-1M-OS-2C0.75S
FRA-TW-1M-OS-4C0.75S
FRA-TW-1M-OS-6C0.75S
FRA-TW-1M-OS-10C0.75S
FRA-TW-1M-OS-18C0.75S
FRA-TW-1M-OS-3P0.75S
FRA-TW-1M-OS-2C1S
FRA-TW-1M-OS-3C1S
FRA-TW-1M-OS-4C1S
FRA-TW-1M-OS-6C1S
FRA-TW-1M-OS-8C1S
FRA-TW-1M-OS-25C1S
FRA-TW-1M-OS-2P1S
FRA-TW-1M-OS-2C1.5S
FRA-TW-1M-OS-3C1.5S
FRA-TW-1M-OS-4C1.5S
FRA-TW-1M-OS-6C1.5S
FRA-TW-1M-OS-18C1.5S
FRA-TW-1M-OS-2C2.5S
FRA-TW-1M-OS-4C2.5S
FRA-TW-1M-OS-6C2.5S
20.75
40.75
60.75
100.75
180.75
320.75
21.0
31.0
41.0
61.0
81.0
251.0
221.0
21.5
31.5
41.5
61.5
181.5
22.5
42.5
62.5
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.3
19/0.3
19/0.3
19/0.3
19/0.3
19/0.4
19/0.4
19/0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
5.0
6.0
7.2
8.7
11.0
9.0
5.6
6.0
6.5
7.8
8.9
13.8
8.3
6.5
6.8
7.4
9.0
14.4
7.8
8.4
11.4
48
72
103
152
244
127
60
76
88
114
171
392
117
86
95
118
168
452
122
152
268
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
195
Standards
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
BS 6360.
Insulation 1: Electron beam crosslinkable
Optional
FRA-DW-1S (Sheathed); FRA-DW-1S-OS (Screened & Sheathed);
FRA-DW-1SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
0.5
0.6
0.75
1.0
1.2
1.5
2.5
/km
40.1
31.1
26.7
20
15.5
13.7
8.21
6.56
5.09
Voltage Rating
KV
196
www.addison-cables.com
0.6/1.0
Cable Code
FRA-DW-1SU-1G0.5
FRA-DW-1SU-1G0.6
FRA-DW-1SU-1G0.75
FRA-DW-1SU-1G1
FRA-DW-1SU-1G1.2
FRA-DW-1SU-1G1.5
FRA-DW-1SU-1G2
FRA-DW-1SU-1G2.5
FRA-DW-1SU-1G3
FRA-DW-1SU-1G4
10.5
10.6
10.75
11.0
11.2
11.5
12.0
12.5
13.0
14.0
19/0.18
19/0.20
19/0.22
19/0.26
19/0.28
19/0.30
37/0.25
19/0.40
37/0.32
56/0.30
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.4
1.3
1.39
1.52
1.67
1.83
2.04
2.29
2.54
2.78
3.21
5.5
6.5
8
10
12
15
19
24
29
39
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
197
Standards
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Conductors: Circular Class 5 stranded
/ BS 6360.
Optional
FRA-DW-1M-FR (Fire resistant )
Electrical Characteristics at 20
Nominal Conductor Cross Section
mm
0.25
0.5
0.75
1.0
1.5
2.5
/km
88.5
40.1
26.7
20
13.7
8.21
Voltage Rating
KV
198
www.addison-cables.com
0.6/1.0
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
20.5
30.5
50.5
90.5
120.5
160.5
250.5
300.5
220.5
20.75
40.75
90.75
140.75
270.75
360.75
31.0
61.0
141.0
201.0
501.0
21.5
51.5
71.5
101.5
181.5
301.5
501.5
32.5
62.5
122.5
182.5
242.5
302.5
362.5
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Nominal Overall
Nominal Weight
Diameter
kg/km
mm
4.0
4.6
5.0
6.7
6.9
7.8
9.5
10.1
5.8
4.4
5.0
7.7
8.4
11.3
12.8
5.0
6.6
9.1
11.2
16.8
5.4
7.1
8.4
9.9
12.4
15.6
20.1
7.0
9.6
12.6
15.3
17.8
19.3
21.0
24
36
43
66
89
115
170
205
50
32
49
106
140
270
360
47
88
174
256
620
55
110
150
170
350
560
870
105
200
360
545
695
870
1050
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
220.25
320.25
420.25
720.25
250.25
20.5
30.5
40.5
50.5
60.5
70.5
80.5
90.5
100.5
120.5
150.5
160.5
19/0.13
19/0.13
19/0.13
19/0.13
19/0.13
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
5.7
6.1
7.0
7.8
8.9
4.3
4.5
4.8
5.4
5.9
6.3
6.8
7.2
7.2
7.4
8.5
8.5
48.9
57.2
72
92
139
34
40
47
58
70
80
86
95
101
112
135
142
199
Cable Code
FRA-DW-1M-OS-18C0.5S
FRA-DW-1M-OS-20C0.5S
FRA-DW-1M-OS-22C0.5S
FRA-DW-1M-OS-25C0.5S
FRA-DW-1M-OS-27C0.5S
FRA-DW-1M-OS-30C0.5S
FRA-DW-1M-OS-36C0.5S
FRA-DW-1M-OS-42C0.5S
FRA-DW-1M-OS-48C0.5S
FRA-DW-1M-OS-50C0.5S
FRA-DW-1M-OS-2P0.5S
FRA-DW-1M-OS-3P0.5S
FRA-DW-1M-OS-4P0.5S
FRA-DW-1M-OS-5P0.5S
FRA-DW-1M-OS-6P0.5S
FRA-DW-1M-OS-8P0.5S
FRA-DW-1M-OS-10P0.5S
FRA-DW-1M-OS-12P0.5S
FRA-DW-1M-OS-15P0.5S
FRA-DW-1M-OS-16P0.5S
FRA-DW-1M-OS-20P0.5S
FRA-DW-1M-OS-2T0.5S
FRA-DW-1M-OS-2C0.75S
FRA-DW-1M-OS-3C0.75S
FRA-DW-1M-OS-4C0.75S
FRA-DW-1M-OS-5C0.75S
FRA-DW-1M-OS-6C0.75S
FRA-DW-1M-OS-7C0.75S
FRA-DW-1M-OS-8C0.75S
FRA-DW-1M-OS-10C0.75S
FRA-DW-1M-OS-12C0.75S
FRA-DW-1M-OS-14C0.75S
FRA-DW-1M-OS-16C0.75S
FRA-DW-1M-OS-18C0.75S
FRA-DW-1M-OS-20C0.75S
FRA-DW-1M-OS-24C0.75S
FRA-DW-1M-OS-25C0.75S
FRA-DW-1M-OS-2P0.75S
FRA-DW-1M-OS-3P0.75S
FRA-DW-1M-OS-4P0.75S
FRA-DW-1M-OS-5P0.75S
FRA-DW-1M-OS-6P0.75S
FRA-DW-1M-OS-7P0.75S
FRA-DW-1M-OS-8P0.75S
FRA-DW-1M-OS-10P0.75S
FRA-DW-1M-OS-3T0.75S
FRA-DW-1M-OS-5Q0.75S
FRA-DW-1M-OS-2C1S
FRA-DW-1M-OS-3C1S
FRA-DW-1M-OS-4C1S
FRA-DW-1M-OS-5C1S
FRA-DW-1M-OS-6C1S
FRA-DW-1M-OS-7C1S
FRA-DW-1M-OS-8C1S
FRA-DW-1M-OS-9C1S
FRA-DW-1M-OS-10C1S
FRA-DW-1M-OS-12C1S
FRA-DW-1M-OS-16C1S
FRA-DW-1M-OS-18C1S
FRA-DW-1M-OS-25C1S
FRA-DW-1M-OS-27C1S
FRA-DW-1M-OS-30C1S
FRA-DW-1M-OS-36C1S
200
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
180.5
200.5
220.5
250.5
270.5
300.5
360.5
420.5
480.5
500.5
220.5
320.5
420.5
520.5
620.5
820.5
1020.5
1220.5
1520.5
1620.5
2020.5
230.5
20.75
30.75
40.75
50.75
60.75
70.75
80.75
100.75
120.75
140.75
160.75
180.75
200.75
240.75
250.75
220.75
320.75
420.75
520.75
620.75
720.75
820.75
1020.75
330.75
540.75
21.0
31.0
41.0
51.0
61.0
71.0
81.0
91.0
101.0
121.0
161.0
181.0
251.0
271.0
301.0
361.0
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.18
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.22
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
8.9
9.3
9.9
10.3
10.5
11.3
12.1
12.9
13.6
14.2
6.4
6.7
7.4
9.2
9.2
9.7
10.9
12.1
13.0
13.0
14.4
7.3
4.8
5.0
5.5
6.1
6.6
7.2
7.8
8.1
8.4
9.1
9.7
10.2
11.1
12.0
12.3
7.1
7.6
9.9
10.7
11.9
13.4
13.2
14.8
8.9
12.8
5.0
5.5
5.8
6.6
7.3
7.9
8.5
8.9
8.9
9.2
10.5
11.2
12.7
13.3
13.8
15.2
162
185
195
213
231
265
301
360
410
430
69
80
95
136
148
155
200
240
300
320
360
90
40
50
62
75
85
100
113
130
150
170
206
230
258
294
300
86
109
143
182
227
279
291
333
151
290
50
60
72
88
114
134
150
160
168
188
250
275
357
395
450
530
www.addison-cables.com
Cable Code
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
FRA-DW-1M-OS-42C1S
FRA-DW-1M-OS-50C1S
FRA-DW-1M-OS-2P1S
FRA-DW-1M-OS-4P1S
FRA-DW-1M-OS-6P1S
FRA-DW-1M-OS-12P1S
FRA-DW-1M-OS-4T1S
FRA-DW-1M-OS-3Q1S
FRA-DW-1M-OS-4Q1S
FRA-DW-1M-OS-2C1.5S
FRA-DW-1M-OS-3C1.5S
FRA-DW-1M-OS-4C1.5S
FRA-DW-1M-OS-5C1.5S
FRA-DW-1M-OS-6C1.5S
FRA-DW-1M-OS-7C1.5S
FRA-DW-1M-OS-8C1.5S
FRA-DW-1M-OS-9C1.5S
FRA-DW-1M-OS-10C1.5S
FRA-DW-1M-OS-12C1.5S
FRA-DW-1M-OS-14C1.5S(G/Y)
FRA-DW-1M-OS-16C1.5S
FRA-DW-1M-OS-18C1.5S
FRA-DW-1M-OS-25C1.5S
FRA-DW-1M-OS-48C1.5S
FRA-DW-1M-OS-2P1.5S
FRA-DW-1M-OS-3P1.5S
FRA-DW-1M-OS-7P1.5S
FRA-DW-1M-OS-2C2.5S
FRA-DW-1M-OS-3C2.5S
FRA-DW-1M-OS-4C2.5S
FRA-DW-1M-OS-5C2.5S
FRA-DW-1M-OS-6C2.5S
FRA-DW-1M-OS-7C2.5S
FRA-DW-1M-OS-8C2.5S
FRA-DW-1M-OS-10C2.5S
FRA-DW-1M-OS-12C2.5S
FRA-DW-1M-OS-16C2.5S
FRA-DW-1M-OS-18C2.5S
FRA-DW-1M-OS-25C2.5S
FRA-DW-1M-OS-27C2.5S
FRA-DW-1M-OS-48C2.5S
421.0
501.0
221.0
421.0
621.0
1221.0
431.0
341.0
441.0
21.5
31.5
41.5
51.5
61.5
71.5
81.5
91.5
101.5
121.5
14G 1.5
161.5
181.5
251.5*
481.5
221.5
321.5
721.5
22.5
32.5
42.5
52.5
62.5
72.5
82.5
102.5
122.5
162.5
182.5
252.5
272.5
482.5
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
19/0.25
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.22
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
37/0.29
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
16.3
17.8
7.9
9.4
11.6
14.3
11.5
11.3
12.5
5.8
6.1
6.7
7.7
8.3
9.1
10.3
10.5
10.5
10.9
12.2
12.5
13.2
15.8
20.7
9.2
9.8
12.6
7.0
7.6
8.4
9.4
10.4
11.4
12.6
13.2
13.6
15.7
16.6
19.3
20.5
25.7
605
690
107
128
240
400
230
245
267
70
81
100
135
155
184
222
234
240
268
333
364
405
562
989
153
205
330
105
130
170
190
225
270
343
370
420
560
620
835
870
1560
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
201
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Outer Sheath (optional): Electron beam crosslinkable LSZH compound (for sheathed cables).
Optional
FRA-SW-3S-OS (Screened & Sheathed);
FRA-SW-3SU-FR(Fire resistant & Unsheathed)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
1.5
13.7
mm
/km
KV
70
0.277
2.5
8.21
95
0.21
4.0
5.09
120
0.164
202
www.addison-cables.com
6.0
3.39
10
1.95
1.8/3
16
1.24
150
185
0.132 0.108
1.8/3
25
0.795
35
0.565
50
0.393
240
300
400
0.0817 0.0654 0.0495
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.5
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
1400.0
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.9
6.8
7.2
7.8
8.3
9.2
10.3
11.8
13.1
14.6
16.4
18.4
20.1
21.7
23.5
26.2
28.6
32.4
70
90
110
130
190
250
330
430
570
760
980
1210
1500
1800
2360
2840
3800
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.5
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
1400.0
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
1.3
1.3
1.3
1.3
2.2
2.2
2.2
2.2
2.2
2.2
2.4
2.4
2.4
2.4
2.4
2.4
2.6
7.3
7.7
8.3
8.8
11.5
12.7
14.1
15.4
17.0
19.0
21.0
22.9
24.7
26.1
29.3
31.9
35.5
80
100
120
140
250
310
410
520
660
880
1130
1370
1690
2000
2620
3140
4140
FRA-SW-3SU-1G1.5
FRA-SW-3SU-1G2.5
FRA-SW-3SU-1G4
FRA-SW-3SU-1G6
FRA-SW-3SU-1G10
FRA-SW-3SU-1G16
FRA-SW-3SU-1G25
FRA-SW-3SU-1G35
FRA-SW-3SU-1G50
FRA-SW-3SU-1G70
FRA-SW-3SU-1G95
FRA-SW-3SU-1G120
FRA-SW-3SU-1G150
FRA-SW-3SU-1G185
FRA-SW-3SU-1G240
FRA-SW-3SU-1G300
FRA-SW-3SU-1G400
FRA-SW-3S (Sheathed)
Cable Code
FRA-SW-3S-1G1.5
FRA-SW-3S-1G2.5
FRA-SW-3S-1G4
FRA-SW-3S-1G6
FRA-SW-3S-1G10
FRA-SW-3S-1G16
FRA-SW-3S-1G25
FRA-SW-3S-1G35
FRA-SW-3S-1G50
FRA-SW-3S-1G70
FRA-SW-3S-1G95
FRA-SW-3S-1G120
FRA-SW-3S-1G150
FRA-SW-3S-1G185
FRA-SW-3S-1G240
FRA-SW-3S-1G300
FRA-SW-3S-1G400
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
203
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Outer Sheath: Electron beam crosslinkable LSZH compound (for sheathed cables).
Optional
FRA-MW-3S-OS (Screened & Sheathed)
FRA-MW-3SU-FR(Fire resistant & Unsheathed)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
1.5
13.7
mm
/km
KV
70
0.277
2.5
8.21
95
0.21
4.0
5.09
120
0.164
204
www.addison-cables.com
6.0
3.39
10
1.95
1.8/3
16
1.24
150
185
0.132
0.108
1.8/3
25
0.795
35
0.565
50
0.393
240
300
400
0.0817 0.0654 0.0495
Nominal Diameter
of Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.5
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
1400.0
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.4
2.4
2.4
2.6
5.8
6.2
6.8
7.3
8.2
9.3
10.8
12.1
13.6
15.4
17.4
19.1
20.7
22.7
25.6
27.9
31.7
50
60
80
100
150
220
290
390
530
720
940
1160
1440
1760
2350
2820
3730
Nominal Diameter
of Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.5
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
1400.0
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
1.3
1.3
1.3
1.3
1.5
1.5
1.8
1.8
1.8
1.8
2.2
2.2
2.2
2.4
2.4
2.4
2.6
6.2
6.5
7.1
7.6
8.9
10
12.5
13.8
15.3
17.2
19.5
21.3
23.3
25.4
28.1
30.5
34.7
60
70
90
110
170
240
350
450
590
790
1050
1270
1590
1900
2490
3010
3980
FRA-MW-3S (Sheathed)
Cable Code
FRA-MW-3S-1G1.5
FRA-MW-3S-1G2.5
FRA-MW-3S-1G4
FRA-MW-3S-1G6
FRA-MW-3S-1G10
FRA-MW-3S-1G16
FRA-MW-3S-1G25
FRA-MW-3S-1G35
FRA-MW-3S-1G50
FRA-MW-3S-1G70
FRA-MW-3S-1G95
FRA-MW-3S-1G120
FRA-MW-3S-1G150
FRA-MW-3S-1G185
FRA-MW-3S-1G240
FRA-MW-3S-1G300
FRA-MW-3S-1G400
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
205
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Optional
FRA-DW-3SU-FR(Fire resistant & Unsheathed)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
mm
/km
KV
1.5
13.7
70
0.277
95
0.21
2.5
8.21
120
0.164
206
www.addison-cables.com
4.0
5.09
6.0
3.39
10
1.95
1.8/3
150
185
0.132
0.108
1.8/3
16
1.24
25
35
50
0.795 0.565 0.393
240
0.0817
300
0.0654
400
0.0495
Nominal Diameter
of Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.5
12.0
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
1400.0
30/0.25
37/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
0.8
0.9
0.9
1.0
1.1
1.2
1.5
1.8
2.0
2.2
2.1
2.3
2.4
2.6
2.8
2.9
3.0
3.4
3.2
3.55
3.75
4.50
5.10
6.35
8.30
10.20
11.70
13.60
15.60
17.30
19.60
21.90
23.80
26.90
29.70
35.80
22
28
34
52
74
120
180
280
390
550
730
940
1180
1510
1800
2290
2910
4040
Nominal Diameter
of Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal Weight
kg/km
11.5
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
0.8
0.9
1.0
1.1
1.2
1.5
1.8
2.0
2.2
2.1
2.3
2.4
2.6
2.8
2.9
3.0
5.2
5.8
6.7
7.4
9.0
11.2
13.4
14.8
16.8
19.0
20.7
23.4
25.9
27.8
31.2
34.2
48
63
89
120
180
280
400
510
700
920
1160
1450
1830
2130
2910
3370
FRA-DW-3SU-1G1.5
FRA-DW-3SU-1G2
FRA-DW-3SU-1G2.5
FRA-DW-3SU-1G4
FRA-DW-3SU-1G6
FRA-DW-3SU-1G10
FRA-DW-3SU-1G16
FRA-DW-3SU-1G25
FRA-DW-3SU-1G35
FRA-DW-3SU-1G50
FRA-DW-3SU-1G70
FRA-DW-3SU-1G95
FRA-DW-3SU-1G120
FRA-DW-3SU-1G150
FRA-DW-3SU-1G185
FRA-DW-3SU-1G240
FRA-DW-3SU-1G300
FRA-DW-3SU-1G400
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
207
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Optional
FRA-SW-6S-OS (Screened)
FRA-SW-6S-FR (Fire resistant)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
1.5
13.7
mm
/km
KV
70
0.277
2.5
8.21
4.0
5.09
95
0.21
208
www.addison-cables.com
120
0.164
6.0
3.39
10
1.95
3.6/6
16
1.24
150
185
0.132 0.108
3.6/6
25
35
50
0.795 0.565 0.393
240
300
400
0.0817 0.0654 0.0495
Nominal Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
1400.0
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.1
3.1
3.2
3.4
3.4
3.4
11.4
12.0
12.5
13.4
14.5
16.0
17.3
19.0
20.8
22.6
24.7
26.3
28.5
31.7
34.2
37.8
170
190
230
300
360
450
560
720
930
1160
1430
1740
2080
2730
3230
4210
FRA-SW-6S-1G2.5
FRA-SW-6S-1G4
FRA-SW-6S-1G6
FRA-SW-6S-1G10
FRA-SW-6S-1G16
FRA-SW-6S-1G25
FRA-SW-6S-1G35
FRA-SW-6S-1G50
FRA-SW-6S-1G70
FRA-SW-6S-1G95
FRA-SW-6S-1G120
FRA-SW-6S-1G150
FRA-SW-6S-1G185
FRA-SW-6S-1G240
FRA-SW-6S-1G300
FRA-SW-6S-1G400
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
209
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
/ BS 6360.
Electron Beam Crosslinkable LSZH Sheath
Optional
FRA-MW-6S-OS (Screened)
FRA-MW-6S-FR (Fire resistant)
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
1.5
13.7
mm
/km
KV
70
0.277
2.5
8.21
4.0
5.09
95
0.21
210
www.addison-cables.com
120
0.164
6.0
3.39
10
1.95
3.6/6
16
1.24
150
185
0.132 0.108
3.6/6
25
35
50
0.795 0.565 0.393
240
300
400
0.0817 0.0654 0.0495
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
1400.0
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
2.6
2.6
2.6
2.6
2.6
2.9
2.9
2.9
2.9
2.9
2.9
2.9
3.2
3.4
3.4
3.4
9.4
9.9
10.4
11.3
12.5
14.9
16.2
17.8
19.6
21.2
23.3
24.9
27.3
30.7
32.2
36.6
120
140
165
220
290
430
540
670
880
1100
1380
1660
2010
2670
3170
4150
FRA-MW-6S-1G2.5
FRA-MW-6S-1G4
FRA-MW-6S-1G6
FRA-MW-6S-1G10
FRA-MW-6S-1G16
FRA-MW-6S-1G25
FRA-MW-6S-1G35
FRA-MW-6S-1G50
FRA-MW-6S-1G70
FRA-MW-6S-1G95
FRA-MW-6S-1G120
FRA-MW-6S-1G150
FRA-MW-6S-1G185
FRA-MW-6S-1G240
FRA-MW-6S-1G300
FRA-MW-6S-1G400
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
211
Standard
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
Construction
Stranded Plain/Tinned Copper Conductor
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
1.5
13.7
mm
/km
KV
70
0.277
2.5
8.21
4.0
5.09
95
0.21
212
www.addison-cables.com
120
0.164
6.0
3.39
10
1.95
3.6/6
16
1.24
150
185
0.132 0.108
3.6/6
25
35
50
0.795 0.565 0.393
240
300
400
0.0817 0.0654 0.0495
FRA-DW-6SU-1G1.5
FRA-DW-6SU-1G2.5
FRA-DW-6SU-1G4
FRA-DW-6SU-1G6
FRA-DW-6SU-1G10
FRA-DW-6SU-1G16
FRA-DW-6SU-1G25
FRA-DW-6SU-1G35
FRA-DW-6SU-1G50
FRA-DW-6SU-1G70
FRA-DW-6SU-1G95
FRA-DW-6SU-1G120
FRA-DW-6SU-1G150
FRA-DW-6SU-1G185
FRA-DW-6SU-1G240
FRA-DW-6SU-1G300
FRA-DW-6SU-1G400
11.5
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
1400.0
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
1.4
1.5
1.6
1.7
1.8
2.1
2.2
2.4
2.6
2.6
2.8
2.9
3.1
3.3
3.4
3.6
3.7
4.4
4.9
5.7
6.3
7.5
9.4
10.9
12.5
14.5
16.5
18.3
20.6
22.9
24.8
27.8
30.8
36.5
20
50
60
90
140
210
300
410
580
770
1000
1260
1610
1920
2470
3000
4220
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
FRA-DW-6S-OS-1G1.5
FRA-DW-6S-OS-1G2.5
FRA-DW-6S-OS-1G4
FRA-DW-6S-OS-1G6
FRA-DW-6S-OS-1G10
FRA-DW-6S-OS-1G16
FRA-DW-6S-OS-1G25
FRA-DW-6S-OS-1G35
FRA-DW-6S-OS-1G50
FRA-DW-6S-OS-1G70
FRA-DW-6S-OS-1G95
FRA-DW-6S-OS-1G120
FRA-DW-6S-OS-1G150
FRA-DW-6S-OS-1G185
FRA-DW-6S-OS-1G240
FRA-DW-6S-OS-1G300
11.5
12.5
14.0
16.0
110.0
116.0
125.0
135.0
150.0
170.0
195.0
1120.0
1150.0
1185.0
1240.0
1300.0
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal Weight
kg/km
1.4
1.5
1.6
1.7
1.8
2.1
2.2
2.4
2.6
2.6
2.8
2.9
3.1
3.3
3.4
3.6
6.6
7.2
8.2
9.1
10.4
12.4
14.3
15.7
17.7
20.1
22.0
24.7
27.1
29.1
32.3
35.6
72
89
120
150
220
330
390
550
740
970
1240
1510
1900
2220
2830
3520
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
213
Standards
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
BS 6387
Construction
Mica Tape
Electron Beam Crosslinkable LSZH Insulation
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
0.5
40.1
0.75
26.7
1.0
20.0
0.45/0.75
1.5
13.7
2.5
8.21
Impact Resistant
Highly Flexible
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
10.5
10.75
11.0
11.5*
12.5*
16/0.20
24/0.20
32/0.2
30/0.25
50/0.25
0.30
0.30
0.35
0.35
0.35
2.0
2.25
2.50
2.8
3.2
8
11
14
19
29
e
FRA-TW-0.5SU-FR-1C0.5S
FRA-TW-0.5SU-FR-1C0.75S
FRA-TW-0.5SU-FR-1C1S
FRA-TW-0.5SU-FR-1C1.5S
FRA-TW-0.5SU-FR-1C2.5S
UV Resistant
Flame Retardant
Fire Retardant
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
214
IEC 61034/NFC20-902
EN 50268/NF C32-073
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
BS 6387
Construction
Mica Tape
/ BS 6360.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
0.5
40.1
0.75
26.7
1.0
20.0
0.45/0.75
1.5
13.7
2.5
8.21
215
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
FRA-TW-0.5M-FR-3C0.5S
FRA-TW-0.5M-FR-26C0.5S
FRA-TW-0.5M-FR-5P0.5S
FRA-TW-0.5M-FR-2C0.75S
FRA-TW-0.5M-FR-4C0.75S
FRA-TW-0.5M-FR-8C0.75S
FRA-TW-0.5M-FR-2C1S
FRA-TW-0.5M-FR-2C1.5S
FRA-TW-0.5M-FR-3C1.5S
FRA-TW-0.5M-FR-5C1.5S
FRA-TW-0.5M-FR-6C1.5S
FRA-TW-0.5M-FR-7C1.5S(G/Y)
FRA-TW-0.5M-FR-12C1.5S(G/Y)
FRA-TW-0.5M-FR-20C1.5S
FRA-TW-0.5M-FR-25C1.5S
FRA-TW-0.5M-FR-37C1.5S
FRA-TW-0.5M-FR-3C2.5S(G/Y)
FRA-TW-0.5M-FR-12C2.5S(G/Y)
FRA-TW-0.5M-FR-25C2.5S(G/Y)
30.5
260.5
520.5
20.75
40.75
80.75
21.0
21.5
31.5
51.5*
61.5
7 G 1.5
12 G 1.5
201.5
*251.5
371.5
3 G 2.5
12 G 2.5
25 G 2.5
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
0.56
0.56
0.56
0.58
0.58
0.58
0.63
0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.66
0.63
0.63
0.63
5.8
14.7
12.9
5.9
7.05
9.3
6.5
7.1
7.7
9.5
10.7
10.3
13.8
17.8
19.6
22.6
8.5
15.9
22.2
41
297
178
40
75
125
61
81
99
150
188
190
319
533
630
889
135
460
900
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
216
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
BS 6387
Construction
Mica Tape
/ BS 6360.
Flame Barrier: Mica tape.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum DC Conductor Resistance
Voltage Rating
mm
/km
KV
1.0
20
mm
/km
KV
25
0.795
1.5
13.7
35
0.565
2.5
8.21
4.0
5.09
0.6/1
6.0
3.39
50
70
0.393
0.277
0.6/1
10
1.95
95
0.210
16
1.24
150
0.132
217
Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
11.0
11.5
12.5
14
16
110
116
125
135
150
170
195
1150
32/0.2
30/0.25
50/0.25
56/0.3
84/0.3
80/0.4
126/0.4
196/0.4
276/0.4
396/0.41
360/0.50
475/0.50
756/0.50
0.55
0.55
0.60
0.65
0.70
0.80
0.90
1.00
1.10
1.20
1.30
1.40
1.60
3.15
3.40
4.05
4.60
5.30
6.35
8.15
9.65
10.80
12.80
15.10
17.00
21.30
18.8
24
36.6
52.5
73
121
181
261
365
530
730
930
1450
FRA-MW-1SU-FR-1G1
FRA-MW-1SU-FR-1G1.5
FRA-MW-1SU-FR-1G2.5
FRA-MW-1SU-FR-1G4
FRA-MW-1SU-FR-1G6
FRA-MW-1SU-FR-1G10
FRA-MW-1SU-FR-1G16
FRA-MW-1SU-FR-1G25
FRA-MW-1SU-FR-1G35
FRA-MW-1SU-FR-1G50
FRA-MW-1SU-FR-1G70
FRA-MW-1SU-FR-1G95
FRA-MW-1SU-FR-1G150
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
218
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
BS 6853 -1a
DIN 5510-1 1-4
NFF 16-101 F0
BS 6387
Construction
Mica Tape
/ BS 6360.
Electrical Characteristics at 20
Nominal Conductor Cross Section
Maximum Conductor Resistance
Voltage Rating
mm
/km
KV
1.5
13.7
mm
/km
KV
25
0.795
2.5
8.21
4.0
5.09
6.0
3.39
10
1.95
16
1.24
70
0.277
95
0.21
120
0.164
1.8/3
35
0.565
50
0.393
1.8/3
219
Nominal Diameter
No. of cores& Nominal
of Strands
Conductor Cross Sectional Area
No/mm
No.mm
FRA-MW-3S-FR-1G1.5
FRA-MW-3S-FR-1G2.5
FRA-MW-3S-FR-1G4
FRA-MW-3S-FR-1G6
FRA-MW-3S-FR-1G10
FRA-MW-3S-FR-1G16
FRA-MW-3S-FR-1G25
FRA-MW-3S-FR-1G35
FRA-MW-3S-FR-1G50
FRA-MW-3S-FR-1G70
FRA-MW-3S-FR-1G95
FRA-MW-3S-FR-1G120
11.5
12.5
14
16
110
116
125
135
150
170
195
1120
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
0.8
0.75
0.95
0.90
1.05
1.20
1.35
1.55
1.85
1.70
1.90
1.95
3.7
3.95
4.95
5.35
6.80
8.60
10.2
11.7
13.8
15.8
17.6
20.2
26
35
55
75
130
190
280
390
550
720
960
1180
30/0.25
50/0.25
56/0.3
84/0.3
80/0.4
126/0.4
196/0.4
276/0.4
396/0.4
360/0.5
475/0.5
608/0.5
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
220
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
221
Standards
DIN 5510-2
Construction
Conductors: Stranded tinned copper
conductor according to IEC 60228 class 5.
Insulation: Foam skin-composite PE
made of inner cellular layer and outer solid skin.
Core Wrapping: Plastic tape(s).
Electrical Characteristics at 20
Nominal Cross Section
Maximum Conductor Resistance
Impedance@1.0-10MHz
Maximum Attenuation @1MHz
Maximum Attenuation @1.5MHz
Maximum Attenuation @2MHz
Maximum Attenuation @3MHz
Maximum Transfer Impedance
Nominal Voltage Rating
mm
/km
dB/km
dB/km
dB/km
dB/km
m/m
V
222
www.addison-cables.com
0.75
26.7
120+/-12
10
13
14
18
30
300
Nominal
Diameter of
Strands
No/mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
20.75
120.75
220.75
19/0.22
19/0.22
19/0.22
1.4
1.4
1.4
8.3
9.0
11.4
97
110
150
RD-WTB-02YCH-2G0.75
RD-WTB-02YCH-1P0.75S
RD-WTB-02YCH-2P0.75S
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
223
Standards
DIN 5510-2
Construction
Plastic Tape
Electrical Characteristics at 20
Nominal Cross Section
Maximum Conductor Resistance
Impedance @0.5-2MHz
Maximum Attenuation @1MHz
Maximum Attenuation @1.5MHz
Maximum Attenuation @2MHz
Maximum Attenuation @3MHz
Maximum Transfer Impedance
Nominal Voltage Rating
mm
/km
dB/km
dB/km
dB/km
dB/km
m/m
V
224
www.addison-cables.com
0.5
41
120+/-12
12.5
15
18
21
20
300
Nominal
Diameter of
Strands
No/mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
120.5+10.5
220.5
19/0.18
19/0.18
1.2
1.2
6.8
8.3
62
100
RD-MVB-02YCH-1P0.5S+1G0.5
RD-MVB-02YCH-2P0.5S
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
225
Standards
DIN 5510-2
Cross-linked Oil Resistance LSZH Sheath
Construction
Electrical Characteristics at 20
e
mm
/km
dB/km
dB/km
m/m
V
0.5
41
120+/-12
17
25
20
300
Nominal
Diameter of
Strands
No/mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
140.5+410.25
19/0.18
0.6
7.9
95
RD-MVB-02YCH-1Q0.5S+4G0.25
Zero
Oil Resistant
226
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
www.addison-cables.com
IEC 61034/NFC20-902
EN 50268/NF C32-073
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
DIN 5510-2
Construction
Electrical Characteristics at 20
Nominal Cross Section/AWG
Maximum Conductor Resistance
Impedance @0.5-2MHz
Maximum Attenuation @1MHz
Maximum Attenuation @2MHz
Nominal Voltage Rating
mm
/km
dB/km
dB/km
V
0.62/20
33.1
120+/-12
10
15
300
227
Nominal
Diameter of
Strands
No/mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
120.62
19/0.2
1.2
8.3
80
RD-WTB/MVB--02Y(ST+C)H-1P20A
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
228
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
DIN 5510-1
Construction
229
Electrical Characteristics at 20
Nominal Cross Section
No of Strand/Strand Diameter
Maximum Conductor Resistant
Impedance@1.0-10MHz
Maximum Attenuation @1MHz
Maximum Attenuation @1.5MHz
Maximum Attenuation @2MHz
Maximum Attenuation @3MHz
Maximum Transfer Impedance
Nominal Voltage Rating
mm
0.75
19/0.22
26.7
120+/-12
10
13
14
18
30
300
/km
dB/km
dB/km
dB/km
dB/km
m/m
V
1
19/0.25
20
-
2.5
37/0.29
8.21
-
6
84/0.3
3.39
-
10
80/0.4
1.95
-
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
410+26+12.5+20.75
410+26+12.5+21.0+20.75
441.0+ 20.75
441.0+ 220.75
1.8
1.8
1.8
1.8
25
25
18.5
23
917
969
498
530
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
230
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
Standards
DIN 5510-2
EN 50228-2-2
BS 6853
EN 50306-3 par 4.8/4.9/4.10
Construction
Plastic Tape
class 5.
Insulation: Electron beam crosslinkable compound.
Cable Element: Individual conductor stranded together.
EMC Screen1: Plastic laminated aluminium-tape.
EMC Screen2: Tinned copper braid.
Separator (s): Plastic tape.
Outer Sheath: Electron beam crosslinkable compound.
For 4222AWG cables:
Center: PE ller.
4 pairs 222AWG: Stranded tinned copper conductor according to IEC 60228 class 5.
Insulation: Electron beam crosslinkable compound.
EMC Screen1: Plastic laminated aluminium-tape.
EMC Screen2: Tinned copper braid.
Separator(s): Plastic tape.
Outer Sheath: Electron beam crosslinkable compound.
231
Electrical Characteristics at 20
Nominal Cross Section
AWG
Nominal Conductor Resistance
Maximum Resistance Unbalance
Maximum Capacitance
Core to Core
Core to Screen
Characteristic Impedance @100MHz
Transfer Impedance f30MHz
Nominal Voltage Rating
mm
/km
/km
0.5
40.1
1.1
22
54.4
1.1
pF/m
pF/m
m/m
V
65
100
100+/-5
200
300
65
100
100+/-5
200
300
Nominal
Diameter of
Strands
No/mm
Nominal
Sheath
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
40.5
422AWG
4222AWG
19/0.18
19/0.16
19/0.16
1.2
1.2
1.2
8.3
7.25
12.6
102
81
174
RD-Cat5E-4C0.5S
RD-Cat5E-4C22A
RD-Cat5E-4P22A
e
Impact Resistant
Highly Flexible
UV Resistant
Weather Resistant
Oil Resistant
Zero
Flame Retardant
Fire Retardant
Zero Halogen
NF C32-070-2.1(C2)
NF C32-070-2.2(C1) IEC 60754-1/NF C20-454
IEC 60332-1/EN 50265-2-1 IEC 60332-3/EN50266
EN 50267-2-1
232
www.addison-cables.com
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453
Low Toxicity
ORDERING INFORMATION
ORDERING INFORMATION
ORDERING INFORMATION
233
B Basic Type
A-: Outdoor Cables
AJ-: Outdoor Cables with inductive protection
CV: Unsheathed Board Wiring Cables (French RATP RATP Railway Standard)
CV-S: Unsheathed Flexible Board Wiring Cables (French RATP Railway Standard)
CVZ: Sheathed Board Wiring Cables (French RATP Railway Standard)
CVZ-S: Sheathed Flexible Board Wiring Cables (French RATP Railway Standard)
ZUG: Multipair Internal Equipment Cables (French RATP Railway Standard)
ZUT: Multipair Screened Internal Equipment Cables (French RATP Railway Standard)
SUG: Multicore Internal Equipment Cables (French RATP Railway Standard)
SCG: Local Control Cables (French RATP Railway Standard)
A1: Unsheathed EPR/LSZH Insulated Railway Signalling Cables (UK NETWORK RAIL Standard)
A2: EPR/LSZH Insulated & LSZH Sheathed Single Core Railway Signalling Cables (UK NETWORK RAIL Standard)
A3: EPR/LSZH Insulated & LSZH Sheathed Multicore Railway Signalling Cables (UK NETWORK RAIL Standard)
B1: EPR Insulated & HDPCP Sheathed Single Core Class 2 Stranded Railway Signalling Cables (UK NETWORK RAIL
Standard)
B2: EPR Insulated & HDPCP Sheathed Multicore Class 2 Stranded Railway Signalling Cables (UK NETWORK RAIL
Standard)
C1: EPR Insulated & HDPCP Sheathed Single Core Class 5 Stranded Railway Signalling Cables (UK NETWORK
RAIL Standard)
234
www.addison-cables.com
ORDERING INFORMATION
www.caledonian-cables.co.uk
C2: EPR Insulated & HDPCP Sheathed Multicore Class 5 Stranded Railway Signalling Cables (UK NETWORK RAIL
Standard)
C3: EPR Insulated & HDPCP Sheathed Single Pair Screened Class 5 Stranded Railway Signalling Cables (UK
NETWORK RAIL Standard)
D1: EPR/LSZH Insulated & LSFROH Sheathed Single Core Class 2 Stranded Railway Signalling Cables (UK
NETWORK RAIL Standard)
D2: EPR/LSZH Insulated & LSZH Sheathed Multicore Class 2 Stranded Railway Signalling Cables (UK NETWORK
RAIL Standard)
E1: EPR/LSZH Insulated & LSZH Sheathed Single Core Class 5 Stranded Railway Signalling Cables (UK
NETWORK RAIL Standard)
E2: EPR/LSZH Insulated & LSZH Sheathed Multicore Class 5 Stranded Railway Signalling Cables (UK NETWORK
RAIL Standard)
EAPSP: Steel Tape Armoured Railway Signalling Cables (Spainish RENFE Railway Standard)
EAPSP-R: Steel Tape Armoured Jelly Filled Railway Signalling Cables (Spainish RENFE Railway Standard)
CCPSSP-FR0.3: Anti Induction PE Sheathed Railway Signalling Cables with Reduction Factor 0.3 (Spainish RENFE
Railway Standard)
CCPSSP-FR0.1: Anti Induction PE Sheathed Railway Signalling Cables with Reduction Factor 0.1 (Spainish RENFE
Railway Standard)
CCPSSP-R-FR0.1: Anti Induction PE Sheathed Jelly Filled Railway Signalling Cables with Reduction Factor 0.1
(Spainish RENFE Railway Standard)
CCTSST-FR0.1: Anti Induction FRNC-PE Sheathed Railway Signalling Cables with Reduction Factor 0.1 (Spainish
RENFE Railway Standard)
CCTSST-FR0.3: Anti Induction FRNC-PE Sheathed Railway Signalling Cables with Reduction Factor 0.3 (Spainish
RENFE Railway Standard)
ZPAU: Anti Induction PE Sheathed Copper Tape Screened Multipair Railway Signalling Cables (French RATP
Railway Standard)
ZPFU: Anti Induction PE Sheathed Unscreened Multipair Railway Signalling Cables (French RATP Railway
Standard)
ZPGU: PE Sheathed Multipair Railway Signalling Cables (French RATP Railway Standard)
ZCO3: Anti Induction PE Sheathed Multiquad Railway Signalling Cables (French RATP Railway Standard)
K23: Anti Induction LSZH Sheathed Multiquad Subway Signalling Cables (French RATP Railway Standard)
K24: LSZH Sheathed Multipair LSZH Sublway Signalling Cables (French RATP Railway Standard)
K13: PVC Sheathed Multipair LSZH Sublway Signalling Cables (French RATP Railway Standard)
DIG: Digicode 30KHz Indoor Signalling Cables ( French RATP Railway Standard)
SXCAV & SXCAG: Switching Centre Signalling Cables ( Belgium SNCB Railway Standard)
SW: Switching Centre Signalling Cables (Swiss SBB Railway Standard)
RT/F3-D type: Unarmoured PE/LSZH Sheathed Axle Counter Cables (UK NETWORK RAIL Standard)
RT/F3-S type: Steel Tape Armoured PE/LSZH Sheathed Axle Counter Cables (UK NETWORK RAIL Standard)
RT/F3-B type: Brass Tape Armoured PE/LSZH Sheathed Axle Counter Cables (UK NETWORK RAIL Standard)
RT/F3-R type: Ruggedised PE Sheahed Axle Counter Cables (UK NETWORK RAIL Standard)
RT/F3-S/E1: PE/LSZH Sheathed Axle Counter Cables Reduction Factor 0.65 (UK NETWORK RAIL Standard)
RT/F3-S/E2: PE/LSZH Sheathed Axle Counter Cables Reduction Factor 0.45 (UK NETWORK RAIL Standard)
RT/F3-S/E3: PE/LSZH Sheathed Axle Counter Cables Reduction Factor 0.2(UK NETWORK RAIL Standard)
SPFB: Speed Control System Balise Cables (French KVB System)
SIF: Speed Control Eurobalise Cables (European ERTMS System)
ORDERING INFORMATION
235
H Electromagnetic Shield
ERTMS System)
K27: Fire Resistant Silicon Rubber Insulated LSZH
Sheathed Signalling Cables
MD4: Fire Resistant Mica Tape Insulated LSZH
Sheathed Railway Signalling Cables
RT/ZHLS: LSZH Sheathed Trackside Telephone Cables
C Insulation
02Y: Cellular PE
2Y: Solid PE
02YS: Foam Skin (Cellular / Solid PE Dual Layer)
Y: PVC
I Armoring
3G: EPR
H: LSZH
Blank: No Armour
D Filling
J Sheath
2Y: PE
Blank: Unlled
E Screening
H: LSZH
Hv: Reinforced LSZH Sheath
5G: HDPCP
Blank: No screen
4Y: PA Sheath
F Bedding
2Y: PE
Y: PVC
NC0.9: N Cores0.9mm
H: LSZH
(L)2Y: Aluminium/PE Laminated sheath
Blank: No Inner Sheath
NC1.4: N Cores1.4mm
NC1.8: N Cores1.8mm
NP0.9: N Pairs0.9mm
NP1.4: N Pairs1.4mm
G Electrostatic Shield
NP1.8: N Pairs1.8mm
NQ0.9: N Quads0.9mm
NQ1.4: N Quads1.4mm
NQ1.8: N Quads1.8mm
NC0.5S: N Cores0.5 mm
NP1.0S: N Pairs1.0 mm
NQ1.5S: N Quads1.5 mm
NG0.5: N Cores0.5 mm
236
www.addison-cables.com
ORDERING INFORMATION
www.caledonian-cables.co.uk
L Cable Category
S- Signal Cables
M Types of Stranding
Bd: Twisted in layers
Lg: Twisted in units
O Reduction Factor
237
B. Basic Types
K25: Class 2 plain copper conductor to IEC 60228, XLPE Insulated, steel tape armoured and low smoke halogen
free polyolen sheathed trackfeeder cables
NSGAFOU: Single Core EPR insulated and PCP sheathed cable
H07RN-F: 450/750V EPR insulated and PCP sheathed cables
H01N2-D: 450/750V CSP sheathed welding cables, HOFR, heat resistant, oil resistant and ame retardant
VV-U: Class 2 plain copper conductor to IEC 60228, PVC insulated and PVC sheathed cables
VV-K: Class 5 exible plain copper conductor to IEC 60228, PVC insulated and PVC sheathed cables
Z1Z1-U: Class 2 plain copper conductor to IEC 60228, low smoke halogen free polyolen insulated and low smoke
halogen free polyolen sheathed cables
Z1Z1-K: Class 5 exible plain copper conductor to IEC 60228, low smoke halogen free polyolen insulated and low
smoke halogen free polyolen sheathed cables
RZ1-U(AS): Class 2 plain copper conductor to IEC 60228, XLPE insulated and low smoke halogen free polyolen
sheathed safety cables
RZ1-K(AS): Class 5 flexible plain copper conductor to IEC 60228, XLPE insulated and low smoke halogen free
polyolen sheathed safety cables
ES07Z-U(AS): 450/750V Class 2 plain copper conductor to IEC 60228, low smoke halogen free polyolen insulated
safety cables, unsheathed
ES07Z-K(AS): 450/750V Class 5 exible plain copper conductor to IEC 60228, low smoke halogen free polyolen
insulated safety cables, unsheathed.
DZ1-U(AS): Class 2 plain copper conductor to IEC 60228, EPR insulated and low smoke halogen free polyolen
sheathed safety cables
DZ1-K(AS): Class 5 flexible plain copper conductor to IEC 60228, EPR insulated and low smoke halogen free
polyolen sheathed safety cables.
DOZ1-U(AS): Class 2 plain copper conductor to IEC 60228, EPR insulated, aluminum/polyester tape screened and
low smoke halogen free polyolen sheathed high safety cables
DOZ1-K(AS): Class 5 flexible plain copper conductor to IEC 60228, EPR insulated , aluminum/polyester tape
screened and low smoke halogen free polyolen sheathed high safety cables
SZ1-U(AS+): Class 2 plain copper conductor to IEC 60228, silicon rubber insulated and low smoke halogen free
polyolen sheathed high safety cables
SZ1-K(AS+): Class 5 exible plain copper conductor to IEC 60228, silicon rubber insulated and low smoke halogen
free polyolen sheathed high safety cables.
SOZ1-U PH90 (AS+): Class 2 plain copper conductor to IEC 60228, silicon rubber insulated, aluminum/polyester
tape screened and low smoke halogen free polyolen sheathed high safety cables with re resistance to EN 50200 PH 90
SOZ1-K PH 90 (AS+): Class 5 exible plain copper conductor to IEC 60228, silicon rubber insulated , aluminum/
polyester tape screened and low smoke halogen free polyolen sheathed high safety cables with re resistance to EN
50200 PH 90
MICC: Solid plain annealed copper, magnesium oxide insulated and copper sheathed re resistant cables.
RZ1MZ1-U (AS): Class 2 plain copper conductor to IEC 60228, XLPE Insulated. steel wire armoured and low smoke
halogen free polyolen sheathed safety cables
RZ1MZ1-K(AS): Class 5 exible plain copper conductor to IEC 60228, XLPE Insulated, steel wire armoured and low
smoke halogen free polyolen sheathed safety cables
RZ1MZ1-U MICA (AS+): Class 2 plain copper conductor to IEC 60228, MICA/XLPE Insulated., steel wire armoured
and low smoke halogen free polyolen sheathed safety cables
238
www.addison-cables.com
ORDERING INFORMATION
www.caledonian-cables.co.uk
RZ1MZ1-K MICA (AS+): Class 5 exible plain copper conductor to IEC 60228, MICA/XLPE Insulated, steel wire
armoured and low smoke halogen free polyolen sheathed safety cables
RZ1F3Z1-U(AS): Class 2 plain copper conductor to IEC 60228, XLPE Insulated, steel tape armoured and low
smoke halogen free polyolen sheathed safety cables
RZ1F3Z1-K(AS): Class 5 exible plain copper conductor to IEC 60228, XLPE Insulated, .steel tape armoured and
low smoke halogen free polyolen sheathed safety cables
VC4VV-U: Class 2 plain copper conductor to IEC 60228, PVC insulated, copper wire braided, PVC inner sheathed
and PVC over sheathed concentric cables
RC4Z1Z1-U: Class 2 plain copper conductor to IEC 60228, XLPE insulated, copper wire braided, low smoke
halogen free polyolen inner sheathed and low smoke halogen free polyolen over sheathed concentric cables
VC4VC4V-U: Class 2 plain copper conductor to IEC 60228, PVC insulated, copper wire spiral screened, PVC inner
sheathed, copper wire braided and PVC over sheathed concentric cables
RC4Z1C4Z1-U: Class 2 plain copper conductor to IEC 60228, XLPE insulated, copper wire spiral screened, low
smoke halogen free polyolen inner sheathed, copper wire braided and low smoke halogen free polyolen over sheathed
concentric cables
RHZ1 H16- Class 2 plain copper conductor to IEC 60228, semi conducting conductor screen, XLPE insulated, semi
conducting insulation screen, copper wire + copper tape screened and low smoke halogen free polyolefin sheathed
medium voltage cables
RHZ1MZ1: Class 2 plain copper conductor to IEC 60228, semi conducting conductor screen, XLPE insulated,
semi conducting insulation screen, individual and overall copper tape screened, low smoke halogen free polyolen inner
sheathed, steel wire armoured and low smoke halogen free polyolen sheathed medium voltage cables
RHVMV: Class 2 plain copper conductor to IEC 60228, semi conducting conductor screen, XLPE insulated, semi
conducting insulation screen, individual and overall copper tape screened, PVC inner sheathed, steel wire armoured and
PVC sheathed medium voltage cables
XKDT: Class 2 plain copper conductor to IEC 60228, semi conducting conductor screen, XLPE insulated, semi
conducting insulation screen, copper wire screened, longitudinal watertight and PE sheathed medium voltage cables
XKDT-YT: Class 2 plain copper conductor to IEC 60228, semi conducting conductor screen, XLPE insulated, semi
conducting insulation screen, three twisted single core, copper wire screened, longitudinal watertight and HDPE sheathed
medium voltage cables
XKDT-FT: Class 2 plain copper conductor to IEC 60228, semi conducting conductor screen, XLPE insulated, semi
conducting insulation screen, three twisted single core, copper wire screened, galvanized steel flat wire armoured,
longitudinal watertight and PE sheathed medium voltage cables
C Voltage Rating
300/500V: 300/500V; 450/750V-450/750V; 0.6/1KV: 600/1000V; 300N-300V DC Negative; 1800P-1800V DC
Positive
6.35/11KV: 6.35/11KV; 19/33KV-19/33KV
ORDERING INFORMATION
239
I Conductor Type
AL: Aluminium CU: Copper
U: Unsheathed
E Screen Type
B Voltage Type
0.5: 300/500V
1: 0.6/1KV
3: 1.8/3KV
6: 3.6/6KV
C Core Type
S: Single Core
M: Multi Core
MP: Multi Pair
240
www.addison-cables.com
ORDERING INFORMATION
www.caledonian-cables.co.uk
G: Sheath
2Y=PE, Y=PVC, H=LSZH, 11Y=PU, A=Aluminium
moisture barrier,
T=Anti-termite protection
C: Fiber type
D: No. of fibers: 1 to 24
J: Strength member
A=Aramid yarn, AG=Aramid yarn and berglass yarn,
G=Fiberglass yarn
E: Bedding
2Y=PE, Y=PVC, H=LSZH
K: General options
SS=Fig-8 self-supporting
F: Armour
Blank=No armour, T=Corrugated steel tape armour,
W=Steel wire armour
B=Bronze armour, D=Fiber glass armour; TW= Steel
tape + Steel wire armour
ORDERING INFORMATION
241
H: Armour
I: Sheath
C: Fiber type
0=Fiber and copper conductors in cable
D: No. of tubes: 1 to 36
jackets;
D=Dry water-blocking between cable jackets;
L: Strength member
F: Central member
S=Solid steel, SR=Stranded steel, F=Fiber
Reinforced Plastic (FRP)
G: Bedding
M: General options
SS=Fig-8 self-supporting
242
www.addison-cables.com
ORDERING INFORMATION
www.caledonian-cables.co.uk
B Cable Category
HCAAYZ-50-6 (1/4): Copper clad aluminium or copper (inner conductor) + annular corrugated copper tube (outer
conductor) 50 1/4foam dielectric exible feeder coaxial cable
HCAAYZ-50-8 (3/8): Copper clad aluminium or copper (inner conductor) + annular corrugated copper tube (outer
conductor) 50 3/8foam dielectric exible feeder coaxial cable
HCAAYZ-50-12 (1/2): Copper clad aluminium (inner conductor) + annular corrugated copper tube (outer
conductor) 50 1/2foam dielectric exible feeder coaxial cable
HCTAYZ-50-22 (7/8): Copper tube (inner conductor) + annular corrugated copper tube (outer conductor) 50 7/8
foam dielectric exible feeder coaxial cable
HCTAYZ-50-32 (1'1/4): Copper tube (inner conductor) + annular corrugated copper tube (outer conductor) 50 1'1/4
foam dielectric exible feeder coaxial cable
HHTAYZ-50-42 (1'5/8): Helical corrugated copper tube (inner conductor) + annular corrugated copper tube (outer
conductor) 50 1'5/8 foam dielectric exible feeder coaxial cable
HRYZ-50-5 (1/4"SF): Copper wire (inner conductor) + helical corrugated copper tube (outer conductor) 50 1/4
foam dielectric super exible feeder coaxial cable
HRCAYZ-50-7 (3/8SF): Copper clad aluminium or copper (inner conductor) + helical corrugated copper tube (outer
conductor) 50 3/8foam dielectric super exible feeder coaxial cable
HRCAYZ-50-9 (1/2SF): Copper clad aluminium (inner conductor) + helical corrugated copper tube (outer
conductor) 50 1/2foam dielectric super exible feeder coaxial cable
HRCTYZ-50-22 (7/8SF): Copper tube (inner conductor) + helical corrugated copper tube (outer conductor) 50
7/8foam dielectric super exible feeder coaxial cable
HRYZ-50-5 (1/4XF): Copper wire (inner conductor) + helical corrugated copper tube (outer conductor) 50 1/4
foam dielectric extra exible feeder coaxial cable
HRCAYZ-50-7 (3/8XF): Copper clad aluminium or copper (inner conductor) + helical corrugated copper tube (outer
conductor) 50 3/8foam dielectric extra exible feeder coaxial cable
ORDERING INFORMATION
243
A Basic Type
L120: Railway F/FTP Data Cables
K20: Steel Wire Braided Railway F/FTP Data Cables
B Construction Type
F/UTP: Overall Aluminium/Polyester Screening
F Armoring
SWB: Steel Wire Braid Armoring
Blank: No Armour
C Cable Category
G Sheath
2Y: PE
Y: PVC
H: LSZH
H No of PairsConductor Diameter
D Insulation
02Y: Cellular PE
4P0.56: 4 Pairs0.56mm
2Y: Solid PE
4P0.6: 4 Pairs0.6mm
244
www.addison-cables.com
UNITED KINGDOM
Marchants Industrial Centre,
Mill Lane, Laughton, Lewes,
East Sussex, BN8 6AJ, UK
T e l: 44-207-4195087
Fax: 44-207-8319489
Email: sales@caledonian-cables.co.uk
Website: www.caledonian-cables.co.uk
HONG KONG
Unit B 22/F CMA Building
64-66 Connaught Road Central
Hong Kong
T e l: 852-36527508
Fax: 852-35834834
Email: hk@caledonian-cables.co.uk
hk@caledonian-cables.com
SHANGHAI
Room 3501, CITIC Square, 1168 Nanjing Xi Lu,
Shanghai 200041, P.R. China
T e l: 86-21-51119178
Fax: 86-21-52524616