Вы находитесь на странице: 1из 8

PROTECTION FOR

ENERGY DISTRIBUTION

Brief Introduction
As a professional power electric equipment manufacturer, we have been supplying our products
(such as: Metal oxide Surge, Metal-oxide Varistro, Fuse Cutouts and Composite insulator, etc) for
power electric transmission and distribution systems to customers world wide.
Products of uncompromising quality backed by comprehensive expertise and the competence
gathered through years of expertise, have made us a prefered supplier of the industry Our highvoltage products are produced under ISO9001 certified quality management system. The quality
is strictly controlled by cur own test laboratory (900kv Impluse Voltage Generater and 250KV
Discharge Testing Equipment).
CANTOR is the firts manufacturer in China who has one-time adquired KEMA certifications
covering over 27 type products. With our combination of technologies, CANTOR can offer reliable
and cost effective overhead protection of distribution systems.

Technology with
Better, cost/Benefit

Two-place locking to prevent sidemovement


of hood, contacts or hooks

Tin-plated bronze terminals for use


with copper or aluminun conductor

Copper current path

Galvanized steel channel

Bird-proofed one-piece
solid-porcelain insulator

Stainless steel backup


spring to maintain contact pressure

Silver-to-silver contacts

Galvanizaed steel hooks for


loadbreak tool

Cast bronze top tube casting


and pull ring
High-strength fiberglass fusetube coated with ultra-violet
inhibitor

Copper current path


Hot stick hole in trunnion casting

Tin-plated bronze terminals


for use with copper or
aluminun conductor

Cast bronze lower tube casting

Silver-to-silver contacts
with stainless steel
backup springs

Stainless steel spring ensures


proper toggle action of fuselink ejector (cast-bronze on all 200A and
linkbreak fuscholders; stainless steel
on all 100A)

Cast bronze hinge for


corrosolon resistance
Fuseholder toggle latch limits
tension of fuselink

Laboratory I

INDEL
to the quality, invested in
the consruction of its
headquarters in the year
2001 with an area of
5.000 m2 where it
produces his traditional
products: Fuse Links
and Braided.

Laboratory II

In 2002 it continued
investing
buying and renovating
a new area with
3.500 m2 to develop
and produce new
products to reach the
expectations and
necessities of the
market, consolidating
the brand
INDEL

CUT - OUT FUSE DISTRIBUTION


CLASS D
THE CUT-OUT FUSE DISTRIBUTION IS USED FOR THE PROTECTION OF
EQUIPMENT IN DISTRIBUTION NETWORKS.
THE FUSEHOLDER WAS DESIGNED TO INTERRUP HIGH INTENSITY
CURRENTS
IT CAN BE USE FOR OPERATIONS WITH CURRENT UP 300A, REPLACING THE
FUSE FOR A SHEET COPPER.
MANUFACTURED IN ACCORDANCE WITH ABNT/ANSI/LEC.
FEATURES
PORCELAIN INSULATOR MADE IN CONFORMITY WITH ABNT, ANSI, AND
IEC.
MAIN CONTACT IN ELECTROLYTIC COPPER
DOBLE WAY PARARELL CONNECTORS IN TINNED COPPER, FOR CABLE
10-120 MM2
HOOK FOR LOAD OPERATIONS
GALVANIZED STEAL HARDWARE
ACCESSORIES
MOUNTING HARDWARE IN ACCORDANCE WITH ABNT/ANSI C-37.40/41/42/
IEC.

NBI

110

NBI

125

NBI

NBI

150

170
Features and Dimensions

D
Base
Code

D-0210011015
D-0410011015
D-1010011015
D-1210011015
D-1610011015
D-1020011015
D-0610012527
D-0810012527

D-1210015038
D-1220015038

Fuseholder

Nominal
Current

Max.
Voltage

NBI

Creepe
Distance

KV

KV

(mm)

Nominal
Current

Dimensions
L

300

15.0

110

240

550

450

407

50

50

300

27.0

125

320

700

450

500

50

50

100

200
100

Braking
Capacity
Sim.

Ass.

1,4
2,8
7,1
8,0
10,6
7,1
4,5
5,3

2,0
4,0
10,0
12,0
16,0
10,0
6,3
8,0

Length
Brazil

Export.

285

2.0

289

2.0

375

378

Note:
Have to beused with extention
Dimensions in milimeters
Doble way conector, 10 to 120 mm2 range

Optional
Fuseholder 200 or Sheet copper
Hord ware Stainler Steal

Fuseholder
021.00 0.2

ARC
Shortening

8.00 0.2

8.00 0.2

021.00 0.2

032.0 0.2

+35
011.00 -0.0

019.1

012.50 0.2

012.50 0.2

025.40 0.2

56.00 0.5
75.00 Min.

56.00 0.5
75.00 Min.

100A

200A

0.5

Assembly Instructions

Hardware

D
38

VOLTAGE
5 = 15KV
27 = 27KV
38 = 38KV

MIX CONFIGURATION TABLE


100

150

12

470

EXTENDER
P= With extender

FUSEHOLDER
CURRENT
00 = 100A
200 = 200A
CURRENT
300 = 300A

HARDWARE
A= Type A
B= Type B
N= With out hardware

NBI
-10 = 110KV
--25 = 125KV
-50 = 150KV
-70 = 170KV
200 = 200KV
BREAKING
CAPACITY
02 = 2KA
05 = 5KA
06 = 6.3KA
08 = 8KA
-0 = 10KA
-2 = 12KA
-6 = 16KA

BOLT
A= GALVANIZED

CREEPE DISTANCE
2 = 240mm NBI 110KV
3 = 320mm NBI 125KV
4 = 470mm NBI 150KV
6 = 660mm NBI 170KV

Вам также может понравиться