Академический Документы
Профессиональный Документы
Культура Документы
tion Manual
Network Planning Parameters
Parameters
BSC Cell Table
Cell System Type
Sub cell Type
Cell Class
BCC
NCC
CGI
Support GPRS
Frequency Hopping Data Table
FH Index No
MA
HSN
TSC
MAIO
CH Type
Range
Default Value
GSM900,GSM1800
Normal, Upper Layer, Lower Layer
Mediium, Upper , Lower Layer
0-7
0-7
MCC:3,MNC:2 to3,LAC:1 to 65535, CI: 0 to 65535
YES, NO
GSM900
Normal
Upper
0 to 65535
0 to 63 (0-cyclic hopping sequence, rest pseudo random)
0-7
0-N-1 N=number of TRX
TCH full rate, TCH half rate 01, TCH half rate 0, SDCCH8, Main
BCCH, Combined BCCH, BCH, BCCH+CBCH, SDCCH+CBCH,
PBCCH+PDTCH, PCCCH+PDTCH, PDTCH, Dynamic PDTCH
Yes
Parameters
Carrier Configuration Table
Static TRX Power class
Range
0~13
Other BTS versions:
The 0529 version or above of BTS30 supports static power class setting of level 0~10.
All versions of BTS20 support the static power setting of levels 0~10;
The microcell BTS supports the static power setting of levels 0~13.
BTS 3001C supports the static power setting of level 0~13.
40W, 60W,Default
OverLaid subcell, UnderLaid subcell, None
Level 0~Level 7
ation Table
With tower-mounted amplifier, Without tower-mounted amplifier
0~255
Default Value
0
Default
Level 0
Unit
Applied Value
Parameters
System Information Table
System Information
Regular transmission
Regular transmission interval
MS MAX retrans
Common access control class
Special access control class
Cell channel description format
ATT
PWRC
UL DTX
CBA
CBQ
EC allowed
Call re-establishment allowed
NCC permitted
CCCH-CONF
Tx-integer
BS_AG_BLKS_RES
BS-PA-MFRAMS
T3212
Radio Link Timeout
MS_TXPWR_MAX_CCH
RXLEV_ACCESS_MIN
Half rate supported
CRH
CBCH CH Description
CBCH mobile allocation
ACS
PI
CRO
TO
PT
ECSC
Power deviation indication
Power deviation
MBR
Cell Configuration Data Table
Data service allowed
Speech version
MAX TA
Frame start time
Paging times
Random access error Thrsh
DC bias voltage Thrsh.
Cell extension type
Cell extension offset
Cell Alarm Threshold Table
Power output error Thrsh.
Power output reduction Thrsh
VSWR TRX error Thrsh
VSWR TRX unadjusted Thrsh
Cell Call Control Table
TCH immediate assignment
Immediate assignment Opt.
Immediate assign to other cell
Assign to other cell
TCH assignment retry
Intra-cell SD to TCH HO
Inter-cell SD to TCH HO
OM start intra-cell HO
OM start inter-cell HO(intra-BSC)
OM start inter-BSC HO
TCH overload alarm
RF CH abnormal release retry
Abis flow control permitted
TCH flow control allowed
Circuit pool
Direct retry
Cell Call Control Parameter Table
T3101
Assign-TCH idle rate Thrsh.
Assign-TCH re-Estb. rate thrsh.
TCH flow control start thrsh.
Max assignment retry times
Idle TCH Thrsh. for SD to TCH HO
Max. radio CH release retry times
Service type Req.(SD to TCH HO)
Syst. delay frame No. adj. value
Response on out BSC HO Req.
Range
1~13. 2bis, 2ter, 5bis, 5ter, 10bis
YES,NO
0~255
1,2,4,7
Level 0~9 forbidd
Level 11~15 forbidden
Bitmap, 1024, 512, 256, 128, Variable-length
YES,NO
YES,NO
Allowed, Mandatory, Forbidden
YES(0), NO (1)
YES(1), NO (0)
YES,NO
YES,NO
0 allowed~7 allowed
1 non-combined CCCH, 1 combined CCCH, 2 non-combined CCCHs, 3 non-combined
CCCHs, and 4 non-combined CCCHs.
3~12, 14, 16, 20, 25, 32, 50
0~7 (non-combined BCCH), 0~2 (1 combined CCCH),
2~9
0~255
4~64, with a step-length of 4
0~20
0~63, (-110dBm~-47dBm)
YES,NO
0~14
YES,NO
YES(1), NO (0)
0~63. Corresponding level value: 0~126db.
0~7. The corresponding value: 0~60db and 7 corresponds to Infinite
0~31. The corresponding time is 20~620s, 31 is a reserve value used to change the
effect of the CRO on C2.
YES,NO
YES,NO
0~3. The corresponding values: 0db. 2db. 4db. 6dB
0~3
NT 12K FULL RATE, NT 12K HALF RATE, NT 12K, NT 6K, T
110~85
110~85
110~85
110~85
110~85
110~85
1~31
0~255
0~255
0~255
0~100
1~255
1~255
0~255
0~63, (-110dBm~-47dBm)
0~255
0~65535
0~255
1~255
1~255
1~255
1~255
1~255
1~255
1~255
0~255
0~65535
0~255
0~255
1~255
Normal cell, Single timeslot extended cell, Dual timeslot extended cell
0~35
0~9, indicating -10dB~-1dB respectively
0~18
0~18
0~18
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
Value range: select circuit pool, deselect circuit pool, system automatic selection
YES,NO
3~50
0~100
0~100
0~7
0~3
0~100
0~3
MSC service request, Location updating request, Paging response, MSC service reestablishment request, Unknown
0
YES,NO
Default Value
1~6. 2bis, 2ter, 5bis, 5ter
YES
10
0
0
Bitmap
YES
YES
Mandatory
YES
NO
YES
YES
111111
Non-combined CCCH
20
2 (non-combined CCCH), 1 (combined CCCH)
2
20~30 (urban), 10~20 (suburb), 8~10 (mountains)
52
5(900M), 0(1800M)
8 (-102dBm)
No
4
NO
YES
0
0
0
NO
NO
1
0
0
111000
Unit
Times
2dB
Applied
Value
dBm
dBm
dBm
dBm
dBm
dBm
SACCH period (480ms)
SACCH period (480ms)
Sec
Sec
%
times
10ms
sec
Grade
Grade
timeslot number
2dB
5ms
5ms
5ms
5ms
5ms
5ms
5ms
100ms
%
%
Idle TCH timeslot in a cell
times
%
times
Parameters
Handover Control Data Table
HO algorithm
Min interval for TCH HOs
Min interval for SD HOs
Min interval for consecutive HOs
Min interval for Emerg. HOs
Co-BSC/MSC Adj
SD HO allowed
Penalty allowed
Intra-cell HO allowed
Load HO allowed
MS fast moving HO allowed
Rx_Level_Drop HO allowed
PBGT HO allowed
MS power prediction after HO
MR. Pre-process
Transfer original MR.
Transfer BS/MS power class
Sent Freq.of preprocessed MR.
Cell Description Table
Layer of the cell
Cell priority
Inter-layer HO Thrsh.
Inter-layer HO hysteresis
Penalty on fast moving HO
Penalty time on fast moving HO
Min DL level on candidate cell
MS_TXPWR_MAX_CCH
UL expected level at HO access
Cell Type
Adjancent Cell Relation Table
Ncell ID
PBGT HO Thrsh.
Inter-cell HO hysteresis
Min access level offset
TA hysteresis
UO HO watch time
UO HO valid time
Assign optimum layer
Assign-optimum-level thrsh.
Pref. subcell in HO of intra-BSC
IntraBSC inc-cell HO Pref. Alg.
Incoming-to-BSC HO optimum layer
Range
Default Value
1~60
1~60
1~60
1~60
YES,NO
YES,NO
YES,NO
YES,NO
Huawei handover
algorithm
6
2
6
6
YES
NO
YES
NO
YES,NO
YES
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
Do not report, Twice every second , Once every second,Once
every 2 sec,One every 4 sec
NO
NO
YES
NO
NO
NO
YES
3
1
25
3
30
40
15
5(900M),0(1800M)
35
Normal Cell
0~63
0~63
0~70,
0~70,
0~70,
0~70,
0~32
1~32
1~32
1~32
1~32
1~32
1~32
4
6
6
3
3
6
6
0~63
0~60
0~63
0~60
0~63
0~60
0~16
30
10
63
10
63
10
10
0~255
63(Normal cell),
219(Dual timeslot
extension cell)
0~7)*10
0~7)*10
0~7)*10
0~7)*10
60
60
50
50
25
30
3
10
0
0
10
2
25
10
5
0~63. (-110dBm~-47dBm)
0~63. (-110dBm~-47dBm)
1~16
1~16
1~16
1~16
1~16
1~16
5
4
5
5
5
5
1~10
1~10
0~255
3
2
15
1~20
1~200
1~200
3
20
6
0~63
0~63
0~63
25
3
0~63
0~63
0~16
5
0~16
4
System optimization, UnderLaid subcell, OverLaid subcell, No
System Optimization
Perence
0~63,(-110dBm~-47dBm)
System Optimization, OverLaid Subcell, UnderLaid Subcell, No
Underlaid Subcell
YES,NO
UnderLaid subcell, OverLaid subcell, No preference
YES
UnderLaid subcell
Unit
Applied Values
sec
Sec
sec
sec
Layer
Grade
Grade
dB
dB
Second
Grade
Grade
dB
dB
Number of MRs
dB
sec
dB
sec
dB
sec
sec
bit period
grade
grade
Bit period
%
%
%
dB
Sec
dB
grade
grade
Sec
Sec
Sec
Sec
Sec
Sec
Sec
Sec
Sec
dB
grade
dB
bit period. 1 bit period
corresponds to 0.55km
dBm
Lowest
Value
7791.9283
Parameters
Power Control Selection Table
PC algorithm
UL PC allowed
DL PC allowed
Ordinary Cell PC Table
RX_LEV Thrsh. for UL increase
RX_LEV Thrsh. for DL increase
P1
N1
RX_LEV Thrsh. for UL decrease
RX_LEV Thrsh. for DL decrease
P2
N2
Qual. Thrsh. for UL increase
Qual. Thrsh. for DL increase
P3
N3
Qual. Thrsh. for UL decrease
Qual. Thrsh. for DL decrease
P4
N4
BTS Power Control Data Table
Power control adjustment period
Expected stable downlink signal strength
Downlink signal strength filter length
Downlink path loss compensation factor
Expected downlink quality
Downlink quality filter length
Downlink quality compensating factor
Minimum base station transmitting power
Maximum power control adjustment step-length
Maximum base station transmitting power
Base station power control level
MS power control data table
Registering period
Expected initial signal strength
Range
Default Value
HW_1.HW_2
YES,NO
YES,NO
HW_2
YES
YES
0~63. (-110dBm~-47dBm)
0~63. (-110dBm~-47dBm)
1~32
1~32
0~63(-110dBm~-47dBm)
0~63(-110dBm~-47dBm)
1~32
1~32
0~7
0~7
1~32
1~32
0~7
0~7
1~32
1~32
20
20
12
10
40
40
12
10
5
5
7
5
0
0
18
15
1~10
0~63
1~32
0~100
0~7
1~32
0~100
0~36
35
5
80
1
5
20
4
1~16
1~58
46(macro cell),36(22c),39(3001C)
1~16,corresponding to 0dB-30dB
16
1~30
0~63
30
1~32
0~63
1~32
0~4
2
30
5 the difference
80 Indicate when
between the current level and the
ideal level is 5dB, power is adjusted
by 4 dB, i.e.,
1 5*80/100)
20. Indicate the difference between
6 and the ideal
the current quality
quality is 1 level, and power is
adjusted by 2 dB. I.e.,
1*20/100)*10
2
1~16
1~30
1~20
1~20
1~20
1~20
YES,NO
0~3
0~3
0~63
0~63
0~7
0~7
0~63
0~63
0~7
0~7
6
6
6
6
YES
2
2
35
25
0
2
40
30
0
2
0~30
16
0~30
0~30
0~4
0~20
0~20
19(900M), 15(1800M)
5(900M), 0(1800M)
46 (macro cell), 36(BTS22C),
39(BTS3001C)
16
1~100
0~7
1~30
0~100
1~58
1~16,corresponding to 0dB-30dB
Unit
Grade
Grade
Grade
Grade
Grade
Grade
Grade
Grade
Applied
Values
Grade
%
Grade
%
Grade,every level
corresponding to 2dB
Grade,every level to
2dB
Number of Mrs
Number of Mrs
Grade
Grade
Grade
Grade
Grade
Grade
Grade
Grade
dB
dB
dB
dB
Power Level
Grade
dBm
Grade
Parameters
Range
YES,NO
0~7
0~31
YES,NO
60~3600
0~cell TCH timeslot number
0~65535
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
0~31
0~70
0~63
0~70
1~32
1~32
1~32
1~32
1~1440
0~63
Default Value
Unit
Huawei I algorithms
NO
3
6
YES
2
Configured SDCCH in
the cell + 8 (too big a
value will not be good
for system recovery
during abnormality)
600
2
Sec
10
Min
YES
YES
YES
YES
YES
YES
31
40
31
40
6
6
2
2
30
2
Grade
Quality grade
value
Grade
Quality grade
value
Minutes
Applied
Values