Вы находитесь на странице: 1из 49

Data Configuration Manual

Huawei 2G BSS Network Plan


1Local Office
2Site
3Cell
4Handover
5Power Control
6Channel

tion Manual
Network Planning Parameters

Parameters
BSC Cell Table
Cell System Type
Sub cell Type
Cell Class
BCC
NCC
CGI
Support GPRS
Frequency Hopping Data Table
FH Index No
MA
HSN
TSC
MAIO

CH Type

Range

Default Value

GSM900,GSM1800
Normal, Upper Layer, Lower Layer
Mediium, Upper , Lower Layer
0-7
0-7
MCC:3,MNC:2 to3,LAC:1 to 65535, CI: 0 to 65535
YES, NO

GSM900
Normal
Upper

0 to 65535
0 to 63 (0-cyclic hopping sequence, rest pseudo random)
0-7
0-N-1 N=number of TRX
TCH full rate, TCH half rate 01, TCH half rate 0, SDCCH8, Main
BCCH, Combined BCCH, BCH, BCCH+CBCH, SDCCH+CBCH,
PBCCH+PDTCH, PCCCH+PDTCH, PDTCH, Dynamic PDTCH

Yes

Unit Applied Value

Parameters
Carrier Configuration Table
Static TRX Power class

Carrier power type


HW-IUO property
TRX priority
Antenna and Feeder Configuration Table
Tower-mounted amplifier flag

Power attenuation factor

Range
0~13
Other BTS versions:
The 0529 version or above of BTS30 supports static power class setting of level 0~10.
All versions of BTS20 support the static power setting of levels 0~10;
The microcell BTS supports the static power setting of levels 0~13.
BTS 3001C supports the static power setting of level 0~13.
40W, 60W,Default
OverLaid subcell, UnderLaid subcell, None
Level 0~Level 7

ation Table
With tower-mounted amplifier, Without tower-mounted amplifier

0~255

Default Value
0

Default
Level 0

In the case that BTS


(including 2.0 and 3.0 base
stations) adopts CDU, CDU
gain should be adjusted
according to the two
parameters described
above.

Unit

Applied Value

Parameters
System Information Table
System Information
Regular transmission
Regular transmission interval
MS MAX retrans
Common access control class
Special access control class
Cell channel description format
ATT
PWRC
UL DTX
CBA
CBQ
EC allowed
Call re-establishment allowed
NCC permitted
CCCH-CONF
Tx-integer
BS_AG_BLKS_RES
BS-PA-MFRAMS
T3212
Radio Link Timeout
MS_TXPWR_MAX_CCH
RXLEV_ACCESS_MIN
Half rate supported
CRH
CBCH CH Description
CBCH mobile allocation
ACS
PI
CRO
TO
PT
ECSC
Power deviation indication
Power deviation
MBR
Cell Configuration Data Table
Data service allowed

Speech version

Speech version priority


Encryption algorithm
BCCH mutual support
FH Mode
SMCBC DRX
DL DTX
BCCH mutual recovery
BBFH TRX mutual support
BBFH TRX mutual recover
Cell Attribute Table
Interf. band Thrsh. 0
Interf. band Thrsh. 1
Interf. band Thrsh. 2
Interf. band Thrsh. 3
Interf. band Thrsh. 4
Interf. band Thrsh. 5
Interf. calculation period
SACCH multi-frames
Radio resource report period
CCCH load indication period
CCCH load Thrsh.
Max resend times of Phy. Info.
T3105
Overload indication period
RACH busy Thrsh
RACH min. access level
Average RACH load TS number
Max RC power reduction
T200 SDCCH(5ms)
T200 FACCH/F
T200 FACCH/H
T200 SACCH TCH SAPI0
T200 SACCH TCH SAPI3
T200 SACCH SDCCH
T200 SDCCH SAPI3

MAX TA
Frame start time
Paging times
Random access error Thrsh
DC bias voltage Thrsh.
Cell extension type
Cell extension offset
Cell Alarm Threshold Table
Power output error Thrsh.
Power output reduction Thrsh
VSWR TRX error Thrsh
VSWR TRX unadjusted Thrsh
Cell Call Control Table
TCH immediate assignment
Immediate assignment Opt.
Immediate assign to other cell
Assign to other cell
TCH assignment retry
Intra-cell SD to TCH HO
Inter-cell SD to TCH HO
OM start intra-cell HO
OM start inter-cell HO(intra-BSC)
OM start inter-BSC HO
TCH overload alarm
RF CH abnormal release retry
Abis flow control permitted
TCH flow control allowed
Circuit pool
Direct retry
Cell Call Control Parameter Table
T3101
Assign-TCH idle rate Thrsh.
Assign-TCH re-Estb. rate thrsh.
TCH flow control start thrsh.
Max assignment retry times
Idle TCH Thrsh. for SD to TCH HO
Max. radio CH release retry times
Service type Req.(SD to TCH HO)
Syst. delay frame No. adj. value
Response on out BSC HO Req.

Range
1~13. 2bis, 2ter, 5bis, 5ter, 10bis
YES,NO
0~255
1,2,4,7
Level 0~9 forbidd
Level 11~15 forbidden
Bitmap, 1024, 512, 256, 128, Variable-length
YES,NO
YES,NO
Allowed, Mandatory, Forbidden
YES(0), NO (1)
YES(1), NO (0)
YES,NO
YES,NO
0 allowed~7 allowed
1 non-combined CCCH, 1 combined CCCH, 2 non-combined CCCHs, 3 non-combined
CCCHs, and 4 non-combined CCCHs.
3~12, 14, 16, 20, 25, 32, 50
0~7 (non-combined BCCH), 0~2 (1 combined CCCH),
2~9
0~255
4~64, with a step-length of 4
0~20
0~63, (-110dBm~-47dBm)
YES,NO
0~14

YES,NO
YES(1), NO (0)
0~63. Corresponding level value: 0~126db.
0~7. The corresponding value: 0~60db and 7 corresponds to Infinite
0~31. The corresponding time is 20~620s, 31 is a reserve value used to change the
effect of the CRO on C2.
YES,NO
YES,NO
0~3. The corresponding values: 0db. 2db. 4db. 6dB
0~3
NT 12K FULL RATE, NT 12K HALF RATE, NT 12K, NT 6K, T

9.6K, T 4.8K, T 2.4K, T 1.2K, T 600 BITS and T 1200/75


Support full rate version 1, support full rate version 2, support full , support half
version 2 and rate version 3 support half rate version 3rate version 1,support half
rate
Support full rate version 1, support full rate version 2, support full , support half
version 2 and rate version 3 support half rate version 3rate version 1,support half
rate version 2, and support half rate version 3.
Not supporting encryption, A5/1~A5/7
YES,NO
Not FH, baseband FH, RF FH
YES,NO
YES,NO
Switchback during resource check, Immediate switchback, No switchback
YES,NO
Switchback during resources check, immediate switchback, no switchback

110~85
110~85
110~85
110~85
110~85
110~85
1~31
0~255
0~255
0~255
0~100
1~255
1~255
0~255
0~63, (-110dBm~-47dBm)
0~255
0~65535
0~255
1~255
1~255
1~255
1~255
1~255
1~255
1~255

0~255
0~65535
0~255
0~255
1~255
Normal cell, Single timeslot extended cell, Dual timeslot extended cell
0~35
0~9, indicating -10dB~-1dB respectively
0~18
0~18
0~18
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
Value range: select circuit pool, deselect circuit pool, system automatic selection
YES,NO
3~50
0~100
0~100
0~7
0~3
0~100
0~3
MSC service request, Location updating request, Paging response, MSC service reestablishment request, Unknown
0
YES,NO

Default Value
1~6. 2bis, 2ter, 5bis, 5ter
YES
10
0
0
Bitmap
YES
YES
Mandatory
YES
NO
YES
YES
111111
Non-combined CCCH
20
2 (non-combined CCCH), 1 (combined CCCH)
2
20~30 (urban), 10~20 (suburb), 8~10 (mountains)
52
5(900M), 0(1800M)
8 (-102dBm)
No
4

NO
YES
0
0
0
NO
NO
1
0
0

111000

Support full rate version 1


10000000
YES
Not FH
NO
YES
No switchback for timeslot FH, Switchback during
resources check for other FHs and non-FH.
Yes for timeslot FH, No for the non-timeslot FH.
No switchback for FH timeslot, Switchback during
resources check for non-timeslot FH.
fixed as 110
105
98
90
87
fixed as 85
20
31
10
15
80
30
7
15
5 (BTS20, BTS22C), 16 (BTS3X)
5
5000
5
60
50
50
150
200
60
60

62 for normal cell, 63 for single TS extended cell, and


219 for dual TS extended cell.
65535
1
180
0
Normal Cell
0(normal cell),34(single TS extended cell)
2
2
2
2
NO
NO
NO
YES
NO
YES
YES
YES
YES
YES
YES
YES
NO
NO
select circuit pool function
YES
30
80
80
2
2
80
1
MSC service request
0
YES

Unit

Times

RACH timeslot (equals to a TDMA frame,


4.615ms)
Block
CCCH multiframes
6 minutes
SACCH period (480ms)
Grade
Grade
2dB

2dB

Applied
Value

dBm
dBm
dBm
dBm
dBm
dBm
SACCH period (480ms)
SACCH period (480ms)
Sec
Sec
%
times
10ms
sec
Grade
Grade
timeslot number
2dB
5ms
5ms
5ms
5ms
5ms
5ms
5ms

bit period (1 bit = 0.55km)


Frame Number
times
dB
km

100ms
%
%
Idle TCH timeslot in a cell
times
%
times

Parameters
Handover Control Data Table
HO algorithm
Min interval for TCH HOs
Min interval for SD HOs
Min interval for consecutive HOs
Min interval for Emerg. HOs
Co-BSC/MSC Adj
SD HO allowed
Penalty allowed
Intra-cell HO allowed
Load HO allowed
MS fast moving HO allowed
Rx_Level_Drop HO allowed
PBGT HO allowed
MS power prediction after HO
MR. Pre-process
Transfer original MR.
Transfer BS/MS power class
Sent Freq.of preprocessed MR.
Cell Description Table
Layer of the cell
Cell priority
Inter-layer HO Thrsh.
Inter-layer HO hysteresis
Penalty on fast moving HO
Penalty time on fast moving HO
Min DL level on candidate cell
MS_TXPWR_MAX_CCH
UL expected level at HO access
Cell Type
Adjancent Cell Relation Table
Ncell ID
PBGT HO Thrsh.

Inter-cell HO hysteresis
Min access level offset

Filter Data Table


Allowed MR number lost
Filter length for TCH level
Filter length for TCH Qual.
Filter length for SD level
Filter length for SD Qual
Filter length for Ncell RX_LEV
Filter length for TA
Penalty table
Penalty level after HO fail.
Penalty time after HO fail
Penalty level after BQ HO Fail
Penalty time after BQ HO Fail.
Penalty time after TA HO Fail
Penalty time after TA HO Fail.
Penalty time after IUO HO Fail.
Emergency Handove Table
TA Thrsh.
DL Qual. Thrsh.
UL Qual. Thrsh.
UL Qual. Thrsh. for interf. HO
DL Qual. Thrsh. for interf. HO
UL RX_LEV Thrsh. for interf. HO
DL RX_LEV Thrsh. for interf. HO
Uplink level SHTM filter length
Filter parameters A1~A8
Filter parameter B
MIN TA
Load Handover Table
System flux Thrsh. for load HO
Load HO Thrsh.
Load Req. on candidate cell
Load HO bandwidth
Load HO step period
Load HO step level
Normal Handover Data Table

Edge HO UL RX_LEV Thrsh.

Edge HO DL RX_LEV Thrsh

Edge HO watch time


Edge HO valid time
PBGT watch time
PBGT valid time
Layer HO watch time
Layer HO valid time
MS Fast Moving HO Data Table
MS Fast-moving Watch cells
MS Fast-moving Valid cells
MS Fast-moving time Thrsh.
Intra-cell Handover Data Table
MAX consecutive HO times
Forbidden time after MAX times
Interval for consecutive HO Jud.
HW-IUO Handover Table
UO signal intensity difference
RX-LEV Thrsh.
RX-LEV Hysteresis
TA Thrsh.

TA hysteresis
UO HO watch time
UO HO valid time
Assign optimum layer
Assign-optimum-level thrsh.
Pref. subcell in HO of intra-BSC
IntraBSC inc-cell HO Pref. Alg.
Incoming-to-BSC HO optimum layer

Range

Default Value

1~60
1~60
1~60
1~60
YES,NO
YES,NO
YES,NO
YES,NO

Huawei handover
algorithm
6
2
6
6
YES
NO
YES
NO

YES,NO

YES

YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
Do not report, Twice every second , Once every second,Once
every 2 sec,One every 4 sec

NO
NO
YES
NO
NO
NO
YES

Huawei handover algorithm, GSM0508 handover algorithm

1~4, which are respectively corresponding to the PICO


layer,MICRO layer, MACRO layer, and UMBRELLA layer
1~16
0~63(-110dBm~-47dBm)
0~63
0~63
0~255
0~63. (-110dBm~-47dBm).
0~31
0~63. (-110dBm~-47dBm)
Normal Cell,Concentric cell

Twice Every Second

3
1
25
3
30
40
15
5(900M),0(1800M)
35
Normal Cell

0~255 for internal cells, and 0~799 for external cells.


0~127, corresponding to -64~63dB

68 for popular urban


areas, 72 for suburbs.

0~63

4dB populous urban


areas and 8dB for
suburts

0~63

0~70,
0~70,
0~70,
0~70,

0~32
1~32
1~32
1~32
1~32
1~32
1~32

4
6
6
3
3
6
6

0~63
0~60
0~63
0~60
0~63
0~60
0~16

30
10
63
10
63
10
10

0~255

63(Normal cell),
219(Dual timeslot
extension cell)

corresponding to RQ (quality level


corresponding to RQ (quality level
corresponding to RQ (quality level
corresponding to RQ (quality level
0~63. (-110dBm~-47dBm)
0~63. (-110dBm~-47dBm)
0~20
0~20
0~255
0~63

0~7)*10
0~7)*10
0~7)*10
0~7)*10

60
60
50
50
25
30
3
10
0
0

0, 8~11; its corresponding percentage values: 0, 70, 80, 90,


95

10

0~7. Its corresponding percentage values: 0, 50, 60, 70, 75,


80,85,90

0~7. Its corresponding percentage values: 0, 50, 60, 70, 75,


80,85,90
0~63
1~60
1~60

2
25
10
5

0~63. (-110dBm~-47dBm)

25 for urban areas


without PBGT
handover being
enabled,
urban)
20 for remote suburbs
20 for urban areas
with PBGT handover
being enabled

0~63. (-110dBm~-47dBm)

30 for urban areas


without PBGT
handover being
enabled
25 for remote suburbs
25 for urban areas
with PBGT handover
being enabled

1~16
1~16
1~16
1~16
1~16
1~16

5
4
5
5
5
5

1~10
1~10
0~255

3
2
15

1~20
1~200
1~200

3
20
6

0~63
0~63
0~63

25
3

0~63

0~63
0~16
5
0~16
4
System optimization, UnderLaid subcell, OverLaid subcell, No
System Optimization
Perence
0~63,(-110dBm~-47dBm)
System Optimization, OverLaid Subcell, UnderLaid Subcell, No

Underlaid Subcell

YES,NO
UnderLaid subcell, OverLaid subcell, No preference

YES
UnderLaid subcell

Unit

Applied Values

sec
Sec
sec
sec

Layer
Grade
Grade
dB
dB
Second
Grade
Grade

dB
dB

Number of MRs

dB
sec
dB
sec
dB
sec
sec

bit period

grade
grade

Bit period

%
%
%
dB
Sec
dB

grade

grade

Sec
Sec
Sec
Sec
Sec
Sec

Sec

Sec
Sec
dB
grade
dB
bit period. 1 bit period
corresponds to 0.55km

bit period, 1 bit period


corresponding to
0.55km
Sec
Sec

dBm

Lowest
Value

7791.9283

Parameters
Power Control Selection Table
PC algorithm
UL PC allowed
DL PC allowed
Ordinary Cell PC Table
RX_LEV Thrsh. for UL increase
RX_LEV Thrsh. for DL increase
P1
N1
RX_LEV Thrsh. for UL decrease
RX_LEV Thrsh. for DL decrease
P2
N2
Qual. Thrsh. for UL increase
Qual. Thrsh. for DL increase
P3
N3
Qual. Thrsh. for UL decrease
Qual. Thrsh. for DL decrease
P4
N4
BTS Power Control Data Table
Power control adjustment period
Expected stable downlink signal strength
Downlink signal strength filter length
Downlink path loss compensation factor
Expected downlink quality
Downlink quality filter length
Downlink quality compensating factor
Minimum base station transmitting power
Maximum power control adjustment step-length
Maximum base station transmitting power
Base station power control level
MS power control data table
Registering period
Expected initial signal strength

Filter length at the initial adjustment phase


Expected stable state signal strength
Stable stage signal filter length
Uplink compensation factor
Expected uplink quality
Quality filter length at stable stage
Uplink quality compensating factor
Power raising range after handover failure
Maximum power control adjusting step-length
HW II power control data table
Power control adjustment period
Uplink level filter length
Downlink level filter length
Uplink quality filter length
Downlink quality filter length
Measuring report compensation switch
Number of predicted uplink MRs
Number of predicted downlink MRs
Uplink signal strength upper threshold
Uplink signal strength lower threshold
Uplink signal good quality threshold
Uplink signal bad quality threshold
Downlink signal strength upper threshold
Downlink signal strength lower threshold
Downlink signal good quality threshold
Downlink signal bad quality threshold
Maximum allowed adjustment step-length in quality
band 0
Maximum allowed adjustment step-length in quality
band 1
Maximum allowed adjustment step-length in quality
band 2
Allowed adjustment step-length for power control
according to quality
Minimum allowed power of MS
Maximum allowed power of MS
Maximum transmit power of base station
Level Number of base station power control

Range

Default Value

HW_1.HW_2
YES,NO
YES,NO

HW_2
YES
YES

0~63. (-110dBm~-47dBm)
0~63. (-110dBm~-47dBm)
1~32
1~32
0~63(-110dBm~-47dBm)
0~63(-110dBm~-47dBm)
1~32
1~32
0~7
0~7
1~32
1~32
0~7
0~7
1~32
1~32

20
20
12
10
40
40
12
10
5
5
7
5
0
0
18
15

1~10

0~63
1~32
0~100
0~7
1~32
0~100
0~36

35
5
80
1
5
20
4

1~16

1~58

46(macro cell),36(22c),39(3001C)

1~16,corresponding to 0dB-30dB

16

1~30

0~63

30

1~32
0~63
1~32

0~4

2
30
5 the difference
80 Indicate when
between the current level and the
ideal level is 5dB, power is adjusted
by 4 dB, i.e.,
1 5*80/100)
20. Indicate the difference between
6 and the ideal
the current quality
quality is 1 level, and power is
adjusted by 2 dB. I.e.,
1*20/100)*10
2

1~16

1~30

1~20
1~20
1~20
1~20
YES,NO
0~3
0~3
0~63
0~63
0~7
0~7
0~63
0~63
0~7
0~7

6
6
6
6
YES
2
2
35
25
0
2
40
30
0
2

0~30

16

0~30

0~30

0~4

0~20
0~20

19(900M), 15(1800M)
5(900M), 0(1800M)
46 (macro cell), 36(BTS22C),
39(BTS3001C)
16

1~100
0~7
1~30
0~100

1~58
1~16,corresponding to 0dB-30dB

Unit

Grade
Grade

Grade
Grade

Grade
Grade

Grade
Grade

SACCH Period (480ms)


Grade
%
Grade
%
dBm
Grade,2dB at each level
dBm
Grade,every level
corresponding to 2dB

SACCH Period (480ms)


Grade

Applied
Values

Grade
%
Grade
%
Grade,every level
corresponding to 2dB
Grade,every level to
2dB

SACCH Period (480ms)

Number of Mrs
Number of Mrs
Grade
Grade
Grade
Grade
Grade
Grade
Grade
Grade
dB
dB
dB
dB
Power Level
Grade
dBm
Grade

Parameters

Range

Radio channel management control table


Channel distribution algorithm selection

Huawei I algorithms and Huawei


II algorithms

Interference band pre-processing switch

YES,NO

Initial length of interference band filter

0~7

Length of averaged interference band

0~31

Whether SDCCH is dynamically distributed

YES,NO

Idle SDCCH channel threshold

The maximum number of SDCCH channel in specifying the maximum number


the cell
of SDCCH in the cell.

TCH Minimum recovery time (second)


TCH Idle threshold N1

60~3600
0~cell TCH timeslot number

TCH decision application period T (minute)

0~65535

HW II Channel Allocation table


SD allocation priority allowed
iInterf. priority allowed
Active Ch Inter.Meas. allowed
AllocationTRX priority allowed
History records priority allowed
Balancetraffic allowed
Interf.of UL Level thrsh.

YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
YES,NO
0~31

Interf. of UL qual. Thrsh.

0~70

Interf. of DL Level Thrsh.

0~63

Interf. of DL Qua. Thrsh.

0~70

Filter length for TCH Level


Filter length for TCH Qual.
Filter length for SDCCH Level
Filter length for SDCCH Qual.
Update Period of CH Record
Update Freq. Of CH record

1~32
1~32
1~32
1~32
1~1440
0~63

Default Value

Unit

Huawei I algorithms
NO
3
6
YES
2
Configured SDCCH in
the cell + 8 (too big a
value will not be good
for system recovery
during abnormality)
600
2

Sec

10

Min

YES
YES
YES
YES
YES
YES
31
40
31
40
6
6
2
2
30
2

Grade
Quality grade
value
Grade
Quality grade
value

Minutes

Applied
Values

Вам также может понравиться