DATOS TCNICOS
DEL PRODUCTO
PRODUCT
TECHNICAL DATA
50/60Hz
NDICE
1. INTRODUCCIN ............................................................................................................................................................. 4
2. CARACTERSTICAS ....................................................................................................................................................... 4
3. TERMINOLOGA ............................................................................................................................................................. 6
4. CARACTERSTICAS FSICAS ........................................................................................................................................ 7
5. CARACTERSTICAS FSICAS CONDENSADORAS ...................................................................................................... 8
6. TABLA DE DATOS ELCTRICOS ................................................................................................................................... 9
7. DIAGRAMAS ELCTRICOS / DISPOSICIN DE LOS COMPONENTES ELCTRICOS ........................................... 10
8. DIMENSIONES (mm) .................................................................................................................................................... 15
9. PROCEDIMIENTO PARA SELECCIN ........................................................................................................................ 17
10. DATOS DE DESEMPEO ........................................................................................................................................... 18
11. TABLAS DE PRDIDA DE CARGA (INTERCAMBIADORES DE CALOR) ................................................................ 19
12. PRDIDAS DE CARGA EN LOS CONDENSADORES .............................................................................................. 20
13. NOTAS PARA DATOS ELCTRICOS ......................................................................................................................... 20
14. GUA PARA ESPECIFICACIONES 30HKS, 020 A 060 ........................................................................................... 21
15. TABLA DE CONVERSIN DE UNIDADES ................................................................................................................. 24
1. INTRODUCCIN
2. 2. Mantenimiento Sencillo
Todas la unidades estn equipadas con control PRODIALOGPLUS NRCP para optimizar la eficiencia del circuito
refrigerante. A todas las unidades se las prueba y se las
carga con refrigerante HCFC22 de fbrica.
2. 3. Subenfriador de Lquido
Nuestros equipos usan la tcnica del subenfriamiento para
mejorar la eficiencia buscando obtener mayor efecto de
refrigeracin por KW consumido. El agua ms fra que
viene de la torre de enfriamiento entra en la parte ms
baja de los tubos de los condensadores (ver dibujo a
seguir).
Salida del agua del
condensador
2. CARACTERSTICAS
2. 1. Instalacin Fcil
Las unidades 30GS tienen un proyecto compacto que ocupa
espacio mnimo en recintos abiertos y se las suministra con
un paquete completo para instalacin. No hay controles
extras, temporizadores, auxiliares de arranque u otros tems
que sern instalados. Las conexiones hidrulicas son
sencillas debido a la utilizacin de flanges en el evaporador.
Cabezal
de salida
Encuentra
tres pasos
Condensador
Refrigerante
condensado
Cabezal de entrada
Direccin de flujo agua
Refrigerante en el
estado lquido inunda el
conjunto subenfriador.
Conjunto
subenfriador
Entrada en el
subenfriador
2. 5. Filtros Secadores
2. 6. Calentadores de Crter
Auxilia cada compresor, mientras est parados, a separar
el refrigerante del aceite y garantizar buena lubrificacin en
nuevo arranque.
2. 7. Display
Uno en cada circuito de refrigeracin, indica el tenor de
humedad en el sistema y es posible determinar la hora de
cambiar los filtros.
Para ms detalles sobre el PRO-DIALOGPLUS NRCP, utilice el manual de Controles y Soluciones de Defectos, cdigo
117.94.016.
3.TERMINOLOGA
30HKS
020
22
Enfriador de lquidos en
condensacin a agua 30HKS
APLICACIN: STANDARD
Frecuencia
Compresor Scroll
6 - 60Hz
5 - 50HZ
Voltaje - fase
22 - 220V/3
38 - 380V/3
44 - 440V/3
Toneladas nominales
020
030
040
050
060
4. CARACTERSTICAS FSICAS
Unidad 30HKS
020
030
040
050
060
50Hz
15,9
23,0
30,9
38,1
44,1
60Hz
20
28
38
47
54
811
935
1245
1445
1535
Ckt A
17,5
21,2
15,7
21,6
21,0
Ckt B
15,7
15,8
21,0
Tipo de compresor*
Scroll
(quant.) Ckt A
(quant.) Ckt B
A1
50
50
25
30,3
25
A2
100
100
50
60,6
50
Ckt B B1
75
80,3
75
B2
100
100
100
50
50
25
30,3
25
234
244
144
154
154
0,016
0,023
0,027
0,031
0,031
219
219
273
273
273
Largo (mm)
1524
2108
1829
2108
2108
Ckt A
R
E
S
F
R
I
A
D
O
R
Enfriador 10 HA400
Carcaza Vol. Lq. (m3)
Tubos
81
81
129
129
129
Largura (mm)
1587
2172
1892
2172
2172
5,89
8,53
11,77
13,58
13,58
Cantidad
Conexiones de Agua
Entrada y Salida
Escurrido*
CONDENSADOR 09RP
2 NPT +
2 NPT +
3 NPT +
3 NPT +
3 NPT +
3/4 NPT
3/4 NPT
3/4 NPT
3/4 NPT
3/4 NPT
CIRC A
022
027
022
027
027
CIRC B
022
022
027
022
027
273
273
Largo (mm)
1728
1728
Carcaza:
Tubos:
46
Largo (mm)
1719
1719
Interna (m2)
2.83
3.42
Externa (m2)
9.19
11.08
Largo (mm)
1782
1719
Interna (m2)
0.37
0.37
Externa (m2)
1.21
1.21
Entrada:
21/2
21/2
Salida:
21/2
21/2
Cantidad
Area:
Area:
3
Lado del Refrigerante 300
Lado del Agua 150
TENSIN
ALIMENTACIN
NOMINAL MNIMA MXIMA
Compresor
CIRCUITO
Compresor
Compresor
OBSERVACIONES IMPORTANTES
Datos obtenidos del catlogo tcnico de compresores de Danfoss Maneurop.
1.
Los valores RLA, KW, RP, RLA Total, y KW Total mostrados en la tabla se refieren a datos nominales de operacin de la unidad en rgimen.
Temperaturas de succin 45 F (7.2 C) y Temperatura de Condensacin 130o F (54.4 C).
2.
Los valores de MOPA mostrados en la tabla fueron calculados a partir de los valores mximos de operacin de la unidad.
3.
Los valores indicados en la columna KVAr estn dimensionados para los compresores cuando hay necesidad de correccin de factor de
potencia para 0.92.
4.
Todos los compresores son del tipo SM Scroll Maneurop (seguido de su capacidad)
UNIDAD
Leyenda
RLA
LRA
MOPA
KW
FP
KVAr
Compresor
CIRCUITO
10
11
12
13
14
8. DIMENSIONES (mm)
ENTRADA AGUA
ENFRIADOR
ENTRADA DE
AGUA DEL
CONDENSADOR
SALIDA DEL
AGUA DEL
CONDENSADOR
SALIDA DEL
AGUA DEL
CONDENSADOR
MQUINA
ANCHO TOTAL
ALTO TOTAL
15
SALIDA DEL
AGUA DEL
CONDENSADOR
SALIDA AGUA
ENFRIADOR
ANCHO TOTAL
16
ENTRADA DE
AGUA DEL
CONDENSADOR
ENTRADA AGUA
ENFRIADOR
MQUINA
ALTO TOTAL
% CORRECCIN
EER
T
Correccin = Valor de la Tabla de Capacidad (x) % de
Correccin de la Capacidad (segn la curva de arriba).
Para un T diferente de 11,3o C, corregir la capacidad y el
EER de acuerdo con los porcentuales (positivos y negativos) de la tabla de arriba.
Se recomienda que las unidades no sobrepasen lmites de
subenfriamiento:
Mnimo: 2,8o C
Mximo 8,3o C
Leyenda:
Cap.
Capacidad de refrigeracin
kW
LCWT
Caudal
L/s
Notas:
1. Las unidades 30HKS salen de fbrica con la vlvula de expansin termosttica regulada para un supercalentamiento de 4C.
2. Los datos de las tablas son para :
T enfriador = 5,5C
T condensador= 5,5C
18
Caudal (l/s)
Caudal (m3/h)
19
Caudal (m3/h)
TERMISTORES/TRANSDUCTORES
Dos termistores se utilizan para suministrar las temperaturas
para el microprocesador. Un tercer termistor, (RT10) puede
usarse como sensor de temperatura remota con el objetivo
de hacer la lectura del aire externo.
SECUENCIA DE CONTROL
CONTROL DE CAPACIDAD
En la primera llamada para enfriamiento el microprocesador
da el arranque en el compresor inicial en la 1 fase del
ventilador en el circuito principal. Los calentadores del crter
se desenergizan cuando el compresor inicia. Si ms
enfriamiento es necesario, ms compresores son
conectados alternndose los circuitos en Lead/Lag. La
velocidad en la cual la capacidad se aumenta o disminuye
es controlada por el desvo de temperatura del punto de
ajuste y la tasa de cambio de temperatura del agua enfriada.
la fbrica.
1.03. - ENTRADA, STOCK Y MANOSEO
A - La unidad debe ser guardada y manoseada conforme
recomendaciones del fabricante.
B - Los controles de la unidad deben ser capaces de
resistir a una temperatura de hasta 85C en el
compartimento de control por un tiempo indefinido.
Los componentes del circuito del refrigerante deben incluir dispositivos de proteccin del lado de alta presin,
vlvulas de servicio de lneas de lquido, filtro secador
con ncleos recambiables, display de humedad, vlvula de expansin termosttica (TXV), y carga completa
de refrigerante para operacin.
G Controles, seguridad y diagnsticos
1 Controles
PARTE 2 - PRODUCTOS
2.01 - Equipo
A - General
Enfriador de lquido con condensacin a aire, pieza
nica, armado en fbrica. Juntamente con el gabinete
de la unidad deben estar todo el cableado, tubera,
controles, carga refrigerante R-22 y las opciones
especiales de fbrica requeridas previamente al
arranque de campo.
B - Gabinete de la Unidad
1 - La estructura debe ser de perfiles de acero galvanizado.
2 - Preparacin de la superficie, a la superficie se la
debe chorrear con abrasivo y grado mnimo SA 2.5.
La limpieza despus del chorro debe hacerse con el
aire seco exento de aceite.
3 - Pintura, aplicacin de shop-primer como mximo
hasta 4h despus del chorro. El espesor de la camada de pintura debe ser de 30 micrmetros.
C - Compresores
1 - Solamente del tipo Scroll.
2 - Armados sobre calces de goma para amortiguacin
de las vibraciones.
D - Evaporador
1 - Tipo casco y tubos con tapa removible
2 - Los tubos deben ser internamente aumentados sin
costuras de cobre y expandidos contra el espejo.
3 - Equipado con conexiones de agua del tipo flange.
4 - El casco debe ser aislado con una espuma de de
PVC (19mm) de factor K mximo de 0,040 W/m.K.
5 - El proyecto debe incorporar 2 circuitos refrigerantes
de expansin directa independientes.
6 - Al evaporador se le debe probar y sellar de acuerdo
con el cdigo ASME para tener una presin del lado
refrigerante de funcionamiento de 1916 kPa y una
presin mnima del lado del agua de 2068 kPa.
E - Condensador
1 - El serpentn es de condensacin a aire con el
subenfriador integral, construida de aletas de
aluminio mecnicamente conectadas a los tubos de
cobre sin enmiendas los cuales se limpian,
deshidratados y sellados.
2 - Los serpentines de condensacin a aire debe
someterse a pruebas de fuga de 1034 kPa, y una
prueba de presin de 3013 kPa.
F - Componentes de Refrigeracin
22
3- Llave de Flujo:
Una llave de flujo del agua enfriada debe ser instalada en campo para detectar bajo flujo del agua.
H Caractersticas operacionales
1 - La unidad debe ser capaz de arrancar con una temperatura de entrada del agua de 35/C en el
evaporador.
2 - El control de capacidad del refrigerante debe
efectuarse a travs del uso del compresor.
3 - Dos circuitos refrigerantes deben proteger contra la
prdida total de capacidad.
4 - La Unidad debe tener la opcin Lead / Lag automtico para automticamente alterar el circuito principal
para asegurar el uso equilibrado de todos los
compresores.
I Motores
1 - Los motores del compresor deben ser enfriados por
el pasaje de gas de succin alrededor de las bobinas del motor.
2 - Motores del ventilador del condensador deben ser
de tres fases con cojinetes permanentemente lubrificados y aislamiento clase B.
J Exigencias Elctricas
1 - El suministro de fuerza elctrica primaria de la unidad
(3 fases) debe ser conectado a un nico local, conforme diagramas elctricos.
2 - La unidad debe ser embarcada con control y cableado
de fuerza instalado en la fbrica
K Opciones Especiales
Entre en contacto con la oficina de ventas local de CARRIER
para auxiliarlo en la mejor aplicacin de las especificaciones.
1- Opcin del material para serpentn del condensador:
la unidad debe estar equipada con un serpentn del
condensador hecha de tubos de cobre y aletas de
cobre.
2- Unidad con brine:
La unidad debe estar equipada en fbrica para
23
Mtrica
Unidad
Sistema
Mtrica
Unidad
Sistema
Tcnica
Americana
Internacional
Tcnica
Americana
Internacional
REA
INTERVALO DE TEMPERATURA
VELOCIDAD
LARGURA
VOLUMEN
MASA
CAUDAL
POTENCIA
TEMPERATURA*
PRESIN
*PARA CONVERSIN DE TEMPERATURA SE
USA EL FACTOR DE CLCULO.
EJEMPLO: A CUNTOS F EQUIVALE 25C:
o
F = (25oC x 1.8) + 32 = 77oF
Notas:
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
24
CONTENTS
1. INTRODUCTION ........................................................................................................................................................... 26
2. CHARACTERISTICS .....................................................................................................................................................26
3. TERMINOLOGY ............................................................................................................................................................28
4. PHYSICAL CHARACTERISTICS .................................................................................................................................. 29
5. CONDENSER PHYSICAL CHARACTERISTICS ......................................................................................................... 30
6. TABLE OF ELECTRICAL DATA .................................................................................................................................... 31
7. ELECTRICAL DIAGRAMS / ELECTRICAL COMPONENT LAY-OUT .......................................................................... 32
8. DIMENSIONS (mm) .......................................................................................................................................................37
9. UNIT SELECTION PROCEDURES ...............................................................................................................................39
10. PERFORMANCE DATA ............................................................................................................................................... 40
11. PRESSURE DROP TABLES (HEAT EXCHANGERS) ................................................................................................ 41
12. PRESSURE DROP IN CONDENSERS ....................................................................................................................... 42
13. ELECTRICAL DATA NOTES .......................................................................................................................................42
14. GUIDELINES FOR SPECIFICATIONS 30HKS, 020 TO 060 ................................................................................... 43
15. TABLE FOR UNIT CONVERSION ..............................................................................................................................46
25
1. INTRODUCTION
2. 2. Simple maintenance
2. 3. Liquid sub-chiller
Our units make use of the sub-chilling technique to improve
efficiency, with the ultimate result of yielding greater cooling
results per kW consumed. The chilled water coming from
the cooling tower enters the lowest point of the condenser
tube bundle (see drawing below).
Water leaving
condenser
Outlet
head
2. CHARACTERISTICS
2. 1. Easy installation
The 30GS units were given a compact design, which takes
up minimum space in open areas and are also provided
with a complete installation package. There are no extra
controls, timers, start-up accessories, nor any other items
that require installation. The hydraulic connections are simple
because flanges are used on the evaporator.
26
3-pass
arrangement
Condenser
Condensed
refrigerant
Sub-chiller
Inlet head
Water flow direction
Liquid-state refrigerant
floods the sub-chiller.
Sub-chiller
inlet
2. 5. Drying filters
The chilling circuits are kept moisture-free to avoid problems
when operating the system.
2. 6. Crankcase heaters
They help the compressors when they are not operating, to
separate refrigerant from oil, thus securing good lubrication
when new start-up routines are necessary.
2. 7. Liquid sightglasses
Each chilling circuit is equipped with one sightglass to
indicate the humidity in the system and therefore establish
the right time to replace filters.
27
For more details about the PRO-DIALOGPLUS NRCP control system please refer to the Control and Troubleshooting
Manual, no. 117.94.016.
3.TERMINOLOGY
30HKS
020
22
Standard use
Frequency
Screw Compressor
6 - 60Hz
5 - 50HZ
Voltage - leading phase
22 - 220V/3
38 - 380V/3
44 - 440V/3
Rated tons
020
28
030
040
050
060
4. PHYSICAL CHARACTERISTICS
Unit 30HKS
Rated capacity (TR)
020
030
040
050
060
50Hz
15,9
23,0
30,9
38,1
44,1
60Hz
20
28
38
47
54
811
935
1245
1445
1535
Ckt A
17,5
21,2
15,7
21,6
21,0
Ckt B
15,7
15,8
21,0
Compressor type*
Screw
(quant.) Ckt A
(quant.) Ckt B
Ckt A
Ckt B
A1
50
50
25
30,3
25
A2
100
100
50
60,6
50
B1
75
80,3
75
B2
100
100
100
50
50
25
30,3
25
234
244
144
154
154
C
H
I
L
L
E
R
0,016
0,023
0,027
0,031
0,031
219
219
273
273
273
Length (mm)
1524
2108
1829
2108
2108
Tubes
Quantity
81
81
129
129
129
Length (mm)
1587
2172
1892
2172
2172
5,89
8,53
11,77
13,58
13,58
Cooling circuit
Maximum pressure* (PSIG)
Water connections
Inlet and outlet
Flow*
CONDENSER 09RP
2 NPT +
2 NPT +
3 NPT +
3 NPT +
3 NPT +
3/4 NPT
3/4 NPT
3/4 NPT
3/4 NPT
3/4 NPT
CIRC A
022
027
022
027
027
CIRC B
022
022
027
29
CONDENSER 09RP
022
027
Carcass:
Outside diam. (mm)
273
273
Length (mm)
1728
1728
Pipes:
46
Length (mm)
1719
1719
Internal (m2)
2.83
3.42
External (m2)
9.19
11.08
Length (mm)
1782
1719
Inside (m2)
0.37
0.37
Outside (m2)
1.21
1.21
Inlet:
21/2
21/2
Outlet:
21/2
21/2
Quantity
Area:
Sub-chiller Pipes +
Quantity
Area:
30
3
Refrigerant 300
Water 150
VOLTAGE
POWER SUPPLY
RATED MINIMUM MAXIMUM
Compressor
CIRCUIT
Compressor
COMPRESSOR DATA
IMPORTANT CONSIDERATIONS
Data obtained from the Danfoss Maneurop compressor technical brochure
1.
RLA, KW, RP, Total RLA, and Total KW shown are rated values for the unit in operation.
Suction temperature 45o F (7.2o C) and condensation temperature 130o F (54.4o C).
2.
MOPA values shown were calculated using maximum operational values of the unit.
3.
KVAr values were established for compressors when it is necessary to correct power factor to 0.92.
4.
All compressors are type SM Screw Maneurop (followed by respective capacity)
UNIT
Compressor
CIRCUITO
Legend
RLA
LRA
MOPA
KW
FP
KVAr
Compressor
31
32
33
34
35
36
8. DIMENSIONS (mm)
COOLER WATER
INLET
CONDENSER
WATER INLET
CONDENSER
WATER INLET
CONDENSER
WATER OUTLET
UNIT
TOTAL WIDTH
TOTAL HEIGHT
37
CONDENSER
WATER OUTLET
COOLER
WATER OUTLET
TOTAL WIDTH
38
CONDENSER
WATER INLET
COOLER WATER
INLET
UNIT
TOTAL HEIGHT
% CORRECTION
EER
39
Legend:
CAP
Chilling Capacity
KW
Power consumption for compressor
LCWT
Chilled water outlet temperature
Flow
L/s
Notes:
1. The 30HKS units are provided with an electronic expansion device adjusted for a 4o C overheating by the manufacturer.
2. The data in the tables are for
T cooler = 5.5o C
T condenser = 5.5o C
40
(kPA)
(l/s)
Flow (m3/h)
41
Flow (m3/h)
THERMISTORS / TRANSDUCERS
Two thermistors are used to send temperature values to
the microprocessor. A third thermistor, (RT10) may be used
as a remote temperature sensor to read the outside air
temperature (OAT).
Four transducers are used to measure the pressure in the
system (see Operation and Troubleshooting Manual).
T1 = chilled water temperature leaving the evaporator.
T2 = temperature of the water entering the evaporator
(return).
T10 = outside air temperature sensor.
CONTROL SEQUENCE
PROTECTION AGAINST NO FLOW
Turn-off cycle during the cycle to turn off the crankcase
heaters are energized.
Start-up after having been turned on, a pre-start procedure
takes place for 2 minutes. This happens for the
microprocessor self checking to self check and wait for the
temperature stabilization. The first circuit to start may be
circuit A or circuit B (automatic Lead / Lag). The control of
the load ramp limits the compressor load at start-up, and
the unnecessary use of the compressor. The microprocessor
limits the supply and therefore water temperature drops (only
at start-up) at 0.60o C per minute.
CAPACITY CONTROL
At the first call to start the chilling, the microprocessor starts
the first compressor and the first stage of the main circuit
fan. The crankcase heaters are de-energized when the
compressors start to operate. If more chilling is necessary,
more compressors are turned on alternating the Lead / Lag
circuits. The speed at which the capacity is increased or
decreased is controlled by the extent in which the
temperature shifts away from the set-point and the rate at
which chilled water changes its temperature.
F - Refrigeration Components
The components of the refrigerant circuit must include
a safety device on the high
pressure side, service valves on the liquid line, drying
filter with changeable cores,
thermostatic expansion valve (TXV), and a complete
refrigerant load.
44
the operation of each switch, thermistor, fan, and compressor before the start-up of the chiller.
c. Send the results to an outside source.
H Operational Characteristics
1 - The unit must be able to start operation with the
water-in temperature at the evaporator of 35o C.
2 - The control of the refrigerant capacity must be carried
out via the compressor.
3 - Two refrigerant circuits must protect against total loss
of capacity.
4 - The unit must be provided with the automatic Lead /
Lag option to automatically interchange the main
circuit, ensuring the balanced use of all compressors.
I Motors
1 - The motors of the compressors must be cooled by
suction gas flowing around the electric coils of the
motor.
2 - The motors of the condenser fans must be threephase, with shafts permanently lubricated and class
B isolation.
J Electrical conditions
1 - The primary power supply (three phases) must be
connected to one only position, as indicated in the
electrical diagrams.
2 - The unit must be shipped with control and power
wiring installed by the manufacturer.
K Special options
Contact the local Carrier sales representative to obtain the
information on how to best apply the specified parameters.
1 - Optional material for the condenser coil: The unit must
be supplied with a coil made with copper tubes and
copper fins.
2 - Brine-operating units: the unit must be supplied so
as to operate with a chilled water-out temperature of
9o C.
3 - One chilled water flow switch must be installed in the
field to detect low water flow.
45
Metric
Unit
System
Metric
Unit
System
Tcnica
American
International
Tcnica
American
International
AREA
TEMPERATURE INTERVAL
SPEED
LENGTH
VOLUME
WEIGHT
FLOW
POWER
TEMPERATURE*
PRESSURE
*TO CONVERT TEMPERATURE USE THE
CALCULATION COEFFICIENT.
EXAMPLE: TO CONVERT 25oC INTO DEGREES
FAHRENHEIT:
o
F = (25oC x 1.8) + 32 = 77oF
Notes:
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
46
47