TECPRO SYSTEM LIMITED

AMBUJA CEMENT LTD

DESIGN BASIS REPORT FOR


BOILER

Revised as per HOLTEC


comments dated 26-62012
Revised as per HOLTEC
comments dated 13-62012

28.06.20
12

22.06.20
12

04.06.20
12

For Approval

REVISION

DATE

DESCRIPTION OF REVISION

NK

NK

AG
S

NK

NK

AG
S

VSM
/NTK

NK

AG
S

INL

PROJECT

INL

SIGN

INL

CHECKED

SIGN

APPROVED

WASTE HEAT RECOVERY BASED POWER PLANT


AT RABRIYAWAS, RAS DISTRICT, RAJASTHAN.

AMBUJA CEMENT LTD.

OWNER

OWNERS CONSULTANT

SIGN

PREPARED

HOLTEC CONSULTING PRIVATE LTD.,


Holtec Centre, A-Block, Sushantlok, Gurgaon.

TECPRO SYSTEMS LIMITED


CHENNAI.

EPC CONTRACTOR

SYSTEM DESIGNER &


SUPPLIER

NANJING TRIUMPH KAINENG ENVIRONMENT


& ENERGY Co., Ltd. NANGJING,CHINA
HIQ POWER ASSOCIATES PRIVATE LIMITED
CHENNAI

EPC CONTRACTOR
CONSULTANT
TECPRO DOC.NUMBER

TSL-1057/03/A/D/003

Total No of Pages : 21
TECPRO SYSTEMS LTD, CHENNAI Page 1

HIQ DOC.NUMBER

Rev.02

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

Project No.

: 1057

Client Name

: Ambuja Cement Ltd,

Rabriyawas.
Consultant Name

: Holtec Consulting Pvt.

Ltd.
Source of Heat

: Cement Kiln Exhaust Gases

Boiler Capacity
AQC Boiler
HP Section
/cm

(a)
AQC Boiler

/cm

: 15870 kg/hr, 11.50 kg

LP Section

0
1

: 3500 kg/hr, 2.80 kg

(a)
Preheater 1 Boiler HP
/cm

: 10180 kg/hr, 11.50 kg

(a)

Preheater 1 Boiler LP

: 1750 kg/hr, 2.80 kg /cm

(a)
Preheater 2 Boiler HP
/cm

: 10180 kg/hr, 11.50 kg

(a)

Preheater 2 Boiler LP

: 1750 kg/hr, 2.80 kg /cm

(a)
o
Superheated Steam Temp. (HP): 335 C (for AQC Boiler)
o
: 305 C (for PH Boilers)
o
Superheated Steam Temp. (LP): 180 C (for PH Boilers)
TECPRO SYSTEMS LTD, CHENNAI Page 2

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

No. of Boilers

: 3 Nos

Reference: HEAT MASS BALANCE DIAGRAM (FA00791C-J010401) REV 01

1. INTRODUCTION:
M/s Ambuja Cement Ltd. is having 1 no. of Kilns with Clinker production capacity
of 6560 TPD with two strings of 06-stage preheater. Kiln has one Clinker cooler.
Exhaust gases from given sources are presently rejected to atmosphere.
Objective is to utilize the waste heat of gases to generate steam and generate
power for captive use by driving steam generator.
M/s Holtec Consulting Private Limited has
carryout PMC Services for this project. The
presently being wasted will be utilized to
temperatures at outlet of all preheater boiler
process heating requirement.

been appointed as consultant to


Exhaust gas heat of Kiln which is
produce steam. The exhaust gas
to be maintained so as to fulfill the

AMBIENT CONDITIONS
Ambient temperature

Max. 45
Average.27
Min. 5

Relative humidity (Min/Max/Average)

3/99/80

Relative humidity for performance

80

Ambient for ACC design

42 deg C

Ambient for Electrical design

50 deg C

TECPRO SYSTEMS LTD, CHENNAI Page 3

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD
SITE CONDITIONS
Seismic zone

II

Basic wind speed

m/s

Site Elevation Above sea level

50m/s
330

Codes and Standards

Sr.
No.

Details

Referred for

IBR 1950 With Latest Amendments

Pressure parts calculations

ASME Section II Part A - Edition 2010

Material Specifications

ASME Section II Part D - Edition 2010

Material Properties

Pressure Vessel Handbook,

Mechanical Calculations

2. Basis of Design
This design basis is intended to cover requirements for design of Waste Heat
Recovery Based Power plant at Rabriyawas, Rajasthan for M/s Ambuja Cement Ltd.
through M/s Tecpro Systems Ltd., Chennai.
The exhaust gases from each of Kiln will enter the respective connected WHRB.
The heat from high temperature exhaust gases will be recovered in WHRB and
after recovery of heat, gases at lower temperature will be exhausted to the ESP.
The system has following major sections:
1.

Super heater

2.

Evaporator

3.

Economizer

4.

Condensate Pre-heater

5.

Steam Drum

6. Damper
7. Boiler feed pump
8. De-aerator
TECPRO SYSTEMS LTD, CHENNAI Page 4

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

9. Blow down Tank


10. Chemical dosing system
11. Dust dislodging system

2.1

0
1

WASTE HEAT RECOVERY BOILER


The PH boiler shall be HP/ LP drum boiler, vertical configuration with
horizontal tubes. AQC boiler shall be HP/ LP drum boiler, vertical
configuration with horizontal tubes. The PH & AQC boilers are top
supported, outdoor Unit suitable for the specified Pre-heater and
Clinker Cooler exhaust of cement plant. The boilers designed for fully
automated operation from DCS. The tube thickness shall be 3.2mm

2.2

Steam Drum
The Steam drum is of welded construction and placed on structure
over the evaporator sections. The material of construction is made of
SA 516 Gr.70. Necessary nozzles and connections for piping and
fittings are provided with supports. Hinged manholes are provided in
both heads of the drum. The drum is provided with suitable two stage
internals to effectively separate saturated steam and to maintain the
required steam purity. Minimum dia. Of steam drum shall be 1372mm.
Type of steam separator is Demister.

2.3

Duct Enclosure
Necessary flue gas ducting from PH outlet to PH boiler and downstream
to fan along with the dampers specified elsewhere in the contract. Inlet
and outlet dampers of PH boiler shall be guillotine sealed motorized
isolation dampers. Damper provided in the bypass duct (PH down
comer) shall be motorized regulating (Multi-Louver) type. PH boiler
casing and ducting thickness for PH boiler shall be minimum of 8 mm
with adequate stiffeners.
For AQC, flue gas duct from mid tap point to De-duster and further to
AQC boiler to the existing bag filer along with dampers specified
elsewhere in the contract. Inlet and outlet dampers of AQC boiler shall
be guillotine sealed motorized isolation dampers. Damper provided in
the cooler exhaust shall be motorized regulating (Multi-Louvrer) type.
One No fresh air damper shall be provided in the air bleed line to
regulate the hot air temperature. Ducting thickness for AQC boiler shall
be minimum 6 mm with adequate stiffeners.

TECPRO SYSTEMS LTD, CHENNAI Page 5

0
2

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

MOC of PH & AQC dampers:


Considering the temperature of flue gas/ air vent, the AQC boiler and
PH boiler are enclosed with carbon steel casing (of specified thickness)
with outside insulation. Necessary access doors for ease of operation
and maintenance shall be considered.
2.4.1 Evaporator
PH boiler Evaporator section is of horizontal, inline tubes and cross-flow
arrangement with headers considering high dust content in the flue
gas. This design feature to be considered shall take into account
minimum accumulation of dust on heating surface.
The AQC boiler evaporator
arrangement with headers.

section

is

horizontal

inline

tube

It shall be connected to the steam drum through adequately sized


down comers and risers, to ensure adequate circulation under all
operating conditions.
2.5

Superheater
Super heater shall be minimum two stage design with primary and
secondary sections. (For AQC Boiler Only)An inter stage de-super
heater of variable multi nozzle orifice with external control valve type
to be provided in between the super heaters to control the final steam
temperature. The de-superheating system shall be provided with all
required isolating valves, piping, insulation, supports, regulating
valves, etc. Supplier shall furnish detailed P&I diagram with line sizes
and instruments. The spray water shall be tapped off from the feed line
at a point, upstream of the feed control station. PH Boiler Superheater
is of Single stage only.

2.6

Economiser
The economizer is considered as the heat recovery unit for raising the
feed water temperature before entering the steam drum of respective
boilers. The economizer shall be Horizontal for AQC boiler and PH
boiler.

2.7

Condensate Preheater System in AQC boiler

TECPRO SYSTEMS LTD, CHENNAI Page 6

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

Condensate pre-heater (CPH) shall be considered as the additional heat


recovery unit to raise the condensate temperature before entering into
de-aerator to reduce the steam consumption in de-aerator.
2.8

Gas / Air Circuit


Exhaust gas from Pre-heater being at higher elevation, the gas ducting
to PH boiler will have a top entry. Hot air from Clinker Cooler being at
lower elevation, the air ducting to AQC boiler will be provided with
bottom entry in pre dust collector. Prior to AQC boiler entry, pre dust
collector shall be provided to reduce the dust concentration before
entering into the boilers. The exhaust from respective sources shall
flows through the various heat transfer sections of each boiler. This
shall be further connected to the existing downstream equipments.
Damper with expansion joints as specified elsewhere in the contract
shall be provided for isolating the boiler during emergency conditions.
The dampers to be considered shall be 99.95% sealing dampers.

2.9

Dust Dislodging System


The dust accumulated on the heat transfer surface of PH boiler shall be
removed and dropped into the bottom hoppers by rapping mechanism.
Hammers mounted on a rotating shaft drop (by gravity) and strike anvils
(solid shaft) that are attached to the pressure part inside the boiler
casing. Rapping intensity shall be controlled by the weight of hammers
and the length of hammer mounting arm. The frequency is changed by
adjusting the speed of the shaft. The design of the dust disposal system
shall be proven.
The collected dust in the hoppers below the PH boiler and other dust
collection points in the system shall be transported through the mass
flow type conveyor to the existing dust conveying system of the cement
plant. Each dust collecting hoppers shall be provided with plate gate,
Rotary air lock valve. These rotary air lock shall discharge the dust to
the mass flow type conveyor below the full length of the boilers. The
discharge of this mass flow type conveyor shall be connected to the
final mass flow type conveyor to transport the dust to the existing
conveying system.

For AQC Boiler:


Due to the abrasive nature of the clinker grains, pre dust collector at the
inlet of AQC boiler to be considered. This shall ease the erosion and
TECPRO SYSTEMS LTD, CHENNAI Page 7

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

abrasion tendency of the heating surfaces and also to collect dust. In


addition to the above, bottom entry/ vertical flow of Hot air in to the
boiler, so that any partial grains that got carried away also settles at the
bottom hopper of the WHRB due to gravity. The collected dust in the
hoppers below the AQC boilers and other dust collection points in the
system shall be transported through the mass flow type conveyor to the
existing dust conveying system of the cement plant. Each dust
collecting hoppers shall be provided with plate gate, Rotary air lock
valve. These rotary air lock shall discharge the dust to the mass flow
type conveyor below the full length of the boilers.
2.10 Method of Flue Gas / Hot Air Isolation
PH Boiler:
Flue gas tapping shall be taken at a higher elevation of the existing PH
exit flue gas duct so as to match with the gas entry point of the WHRB.
The exit of the WHRB is again to be connected to the PH fans inlet duct
at a lower elevation.
The type of dampers and their positioning shall be clearly specified
considering no dust accumulation on the dampers.
AQC Boiler:
The air above the inlet section of the Clinker cooler after mixing with
the ambient air from the cooler fan will be at a very high temperature.
The hot air mixture tapped above the cooler grate in this section will
then be recycled as secondary and tertiary air to the kiln for clinker
production. The section after the secondary and tertiary air tapping is
the location identified for tapping the hot air required for heat recovery.

2.11 Common Blow Down Tank


One no. blow down tank to be considered for each to which the boiler
Blow down, boiler drain lines from various system will be connected.
2.12

Water and Steam Circuit

TECPRO SYSTEMS LTD, CHENNAI Page 8

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

Feed water enters the common condensate pre-heater, de-aerator,


from de-aerator outlet to economizer from BFP/ feed control station,
from economizer outlet it is fed to the Steam drum. From the drum the
water enters to the evaporator inlet header. After absorbing heat from
the heat sources, steam-water mixture formed and moved to the
respective steam drum through natural circulation. Separated
saturated steam from steam drum shall be heated in respective superheater.
2.13 Common De-aerator cum storage tank
Pressurized de-aerator shall be provided by the supplier along with LP
dosing system. The location of de-aerator along with BFP shall be
provided in the TG hall .This system shall consists of De-aerator in
which the oxygen content in the feed water is reduced to the required
level by spraying water as droplets in the presence of steam. Storage
tank below the De-aerator to store de-aerated water.
2.14

Chemical Dosing System


LP Dosing System
Since feed water contains traces of oxygen due to the incomplete
mechanical / thermal deaeration. Traces of oxygen shall be scavenged
by chemical deaeration. Chemicals like sodium sulphite or hydrazine
shall be dosed in the suction pipe of feed pump by LP dosing. LP dosing
with sodium sulphite is to be considered to reacts with oxygen and to
form sodium sulphate or in case of hydrazine, it reacts with O 2 and
forms water and nitrogen.
HP dosing system
Scale formation is limited by converting hardness salts to a free flowing
sludge. HP dosing is done by carbonate control and phosphate control
by addition of sodium carbonate or trisodium phosphate respectively.
Other chemicals such as sodium hydroxide carbonate or calcium
oxyphosphate can also be added. Best result of calcium carbonate or
magnesium hydroxide or calcium silicate, magnesium silicate will be
available as free flowing sludge where caustic alkalinity is 10 to 15% of
the dissolved solids. OH alkalinity leads to prevention of magnesium
phosphate as bad scale by converting magnesium to magnesium
hydroxide. The HP dosing system shall add the chemical to the boiler
water to take care of the ingress of the hardness salt and to increase
the boiler water pH.

TECPRO SYSTEMS LTD, CHENNAI Page 9

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

2.15 Water quality index of circulation cooling water


N0.

Item

Make-up water quality

pH

7.0-9.2

Suspended
solid(SS)

10mg/L

Oil & grease

Cl

300 mg/L

methyl orange
alkalinity

500 mg/L

Ca2+

30-200 mg/L

Fe2+

0.5 mg/L

SO42-

1500 mg/L

SiO2

175 mg/L

10

Free chlorine

0.5-1.0 mg/L

Remark
0
2

Demineralization water quality requirement:

2.16

No.

Item

Make-up water quality

pH

8.0-9.5

Hardness

0.03mmol/L

Turbidity(FTU)

oil

2.0 mg/L

Total ferrum

0.3 mg/L

Conductivity

110 S/cm

Remark

Boiler steam drum feed water, boiler water standards

The quality control standards of drum feed water GB1576-2008 are as


follows:

TECPRO SYSTEMS LTD, CHENNAI Page 10

0
2

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

S/N

Item

Unit

Control standards

SS
PH
value25Deg
C

mg/L

non
dimension

mmol/L

0.03

Total hardness
dissolved
oxygen

mg/L

0.05

Oil content

mg/L

Iron content

mg/L

0.3

2
3

The quality control standards of steam drum waterGB1576-2008are as


follows:
S/N

Item

Unit

Control standards

Total alkalinity

14

1012

pH25
dissolved
solid

mmol/L
non
dimension
mg/L

100

PO43-

mg/L

1030

SO32Relative
alkalinity

mg/L
non
dimension

1030

0.2

2.17 Boiler Feed Pumps


Two (02) nos, (01 working+01 standby). each capable of meeting feed
water requirement at 110% BMCR capacity of each boiler (excluding
the pump margins), horizontal, multistage, barrel casing, centrifugal
type boiler feed pumps, driven by electric motor would be provided.
Each pump would be provided with forced lubricating oil system for
lubrication of the bearings, couplings etc. All necessary protective and
supervisory system would be provided to ensure safe and trouble-free
operation of the feed pumps.

3.1 Design Data

S No

Description

TECPRO SYSTEMS LTD, CHENNAI Page 11

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD
A

Clinker production capacity-BDP

Source of exhaust

Clinker Cooler

Pre heater
(VI Stage)

Nature of exhaust

Hot Air

Flue Gas

HEATING SIDE

Ambient Temperature

6560 TPD

Unit

AQC boiler

Total Exhaust Flow available for


design

Nm3/hr

Flow rate

kg/hr

Exhaust tapping location

Density

Temperature

At tapping point

Inlet of WHR

Outlet of WHR

Composition

Max.45

Max.45

Average.27

Average.27

Min.5

Min.5

174,000

222720
Mid Tap Off

Kg/Nm

C
C
C
C

PH boiler 1 &
2. each

ILC -1 :
132,000
ILC - 2 :
132,000

188760
Pre heater Exit

1.28

360
355

1.43

ILC-1
ILC-2
ILC-1
ILC-2

:330
:330
:325
:325

100

179

CO2

Nil

26.7/24.2

CO

N2

79.00

65.2~6
8.3

H2O

0.10

3 3.5

O2

20.3

4 - 4.6

Dust concentration in exhaust


gas

10

Fouling factor

11

Pressure

TECPRO SYSTEMS LTD, CHENNAI Page 12

% by
volume

3
gms/Nm

50
0.0001

ILC-1: 108
ILC-2: 108
0.0001

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD
a

At Inlet of WHRB

mmwc

Max. pressure drop across WHRB


boiler
Max. pressure drop across WHRB
system(taping to taping)
including inlet duct, outlet
duct,pre-duster(in case of AQC)
and boiler

mmwc

11

No. of WHRB

12

Condenser t

13
14

15

mmwc

Nos.

-50

ILC -1: -720


ILC -2: -720

<60

< 70

<90

<100

type

ACC

Condensing pressure

Kg/cm2(a)

Water Temperature

Power generation voltage

0.2 at 42 deg C
34

34

6600+10%

3.2. Output Specifications


a) Flue Gas Specifications

Sr. No.

Details

Ambient Temperature

Exhaust gas outlet


temperature
Pressure drop across
WHRS

Unit
O

mmWC

Clinker
Cooler

Pre Heater 1
Boiler

Pre Heater 2
Boiler

3
5
10
0
6
0

35

35

179

179

70

70

b) Steam Specifications

Sr.
No

Steam Data

Unit

Steam Generation HP/LP


1

TPH

TECPRO SYSTEMS LTD, CHENNAI Page 13

Clinker
Cooler
15.87/
3.5

Pre Heater 1
Boiler
10.18/
1.75

Pre Heater 2
Boiler
10.18/
1.75

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

Steam Pressure at HP/LP


Super heater main steam
stop valve outlet
Steam temperature at
HP/LP Super heater main
steam stop valve outlet

kg/cm2
(a)
O

11.5 /
2.8

11.5/
2.8

11.5/
2.8

335
180

305
180

305
180

4. Design Specifications
4.1

Super Heater

i. Material of Construction
a. Tubes

: SA 210 Gr. A1, Seamless

b. Headers

: SA 106 Gr. B

0
2

ii. Design
Header size: During detail engineering
a. Gas Side Specifications
Type of flow: Cross flow
Arrangement: Staggered

Sr.
No.
A

Details

0
2

Unit

Clinker
Cooler

Pre Heater 1
Boiler

Pre Heater 2
Boiler

174000

132000

132000

222355

189683

198683

355

325

325

195

213

213

222355

189683

189683

Inlet

Exhaust gas flow rate

Nm3/hr

Exhaust gas flow rate

Kg/hr

Exhaust gas inlet temperature


for HP Super heater

Exhaust gas inlet temperature


for LP Super heater

B
1

0
1

Outlet
Exhaust gas flow rate

kg/hr

TECPRO SYSTEMS LTD, CHENNAI Page 14

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

331

311

311

193

207

207

Exhaust Gas Velocity at HP


super heater

m/s

4.9

5.6

5.6

Exhaust Gas Velocity at HP


super heater

m/s

4.2

5.1

5.1

Exhaust gas outlet temperature


for HP Super heater

Exhaust gas outlet temperature


for LP Super heater

4
5

b. Fluid Side Specifications

Sr.
No.
A

Detail
s
Inlet

Flow rate HP /LP

Steam inlet
Temperature HP/LP

Unit

kg/hr
O

C
2

Clinker
Cooler

Pre Heater 1
Boiler

Pre Heater 2
Boiler

15870/
3300
188/
132
13.5/
3.8

10180/
1750
188/
132
13.5/
3.8

10180/
1750
188/
132
13.5/
3.8

Design pressure
HP/LP

kg/cm (a)

Working pressure
HP/LP

kg/cm (a)

12.5/
3.2

12.5/
3.2

12.5/
3.2

Design temperature
HP/LP

425/
250

350/
250

350/
250

Working temperature
HP/LP

335/
180

305/
180

305/
180

Type of fin

Bottom two
rows of bare
tube type,
Balance rows is
finned tube
type

Bare type

Bare type

Fins per Inch

Fin materials

CS

TECPRO SYSTEMS LTD, CHENNAI Page 15

0
1

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

10
B
1
2

Type of fin weld

Resistant
welded

15870/
3500

10180/
1750

10180/
1750

335/
180

305/
180

305/
180

1382/
377

561/
78

561/
78

12.5/
2.8

12.5/
2.8

12.5/
2.8

Outlet
Flow rate HP/LP

kg/hr

Superheated
steam outlet
temperature

Heating surface area


HP/LP

Safety valve set


pressure HP/LP

kg/cm (g)

4.2 HP Evaporator
i. Material of Construction
a. Tubes

: SA 210 Gr. A1, Seamless

b. Headers

: SA 106 Gr. B

0
2

Inner Casing material : IS 2062 GB or equivalent


Outer Casing material: GI/Colour sheet 0.5mm thick

0
2

ii. Design Specifications


a. Gas Side Specifications
b. Header size : 219.1

Sr.
No.
A

Details

0
1

Unit

Clinker
Cooler

Pre Heater 1
Boiler

Pre Heater 2
Boiler

Inlet

Exhaust gas flow rate

Kg/hr

222355

189683

189683

Exhaust gas flow rate

Nm3/hr

174000

132000

132000

Exhaust gas inlet temperature


HP/LP

331/
177

311/
198

311/
198

TECPRO SYSTEMS LTD, CHENNAI Page 16

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

Outlet

Flow rate

Exhaust gas outlet temperature


HP/LP

Exhaust Gas Velocity HP/LP

222355

189683

189683

195/
142

213/
179

213/
179

m/s

4.4/
4.2

5.4/
4.9

5.4/
4.9

kg/hr
O

b. Fluid Side Specifications

Sr.
No.
A

D
et
Inlet

Water inlet
temperature HP/LP

Design pressure
HP/LP
Working pressure
HP/LP

3
4
5

Design temperature
HP/LP
Working temperature
HP/LP

Type of fin

Fins per Inch

Fin materials

10

Type of fin weld

Outlet

Water & steam


mixture outlet
temperature
HP/LP

Unit

C
2

kg/cm (a)
2

kg/cm (a)
O

Clinker
Cooler

Pre Heater 1
Boiler

Pre Heater 2
Boiler

188/
133

188/
133

188/
133

14.5/
4
13.5/
3.5

15/
4
14/
3.5

15/
4
14/
3.5

197/
144

199/
144

199/
144

194/
139

194/
139

194/
139

Fin type

Bare type

Bare type

CS

Resistant welded

189/
135

189/
138

189/
138

TECPRO SYSTEMS LTD, CHENNAI Page 17

0
1

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

Heating surface area

9230/
5259

2911/
728

2911/
728

4.3 HP Economizer
i. Material of Construction
a. Tubes

: SA 210 Gr. A1

b. Headers

: SA 106 Gr. B

ii. Design Specifications


a.
b.
c.
d.
e.

Sr.
No.
A

Gas Side Specifications


Type: Staggered
Header Size :219.1
Inner Casing Material :IS 2062 or equivalent
Outer casing : GI/Coloured sheet 0.5mm thick

Details

Unit

Clinker
Cooler

0
1

0
2

Pre Heater 1
Boiler

Pre Heater 2
Boiler

Inlet

Exhaust gas flow rate

Exhaust gas flow rate

Exhaust gas inlet temperature


HP/LP

Oulet

Flow rate

Exhaust gas outlet temperature


HP/LP

Exhaust Gas Velocity HP/LP

Kg/hr

222355

189683

189683

174000

132000

132000

213/--

213/--

222355

189683

189683

177/124

196/--

196/--

m/s

4/3.6

Nm3/hr
O

kg/hr
O

193/142

b. Fluid Side Specifications

Sr.
No.

Details

Unit

TECPRO SYSTEMS LTD, CHENNAI Page 18

Clinker Pre Heater 1


Cooler
Boiler

Pre Heater 2
Boiler

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

Inlet

Flow rate HP/LP

Water inlet temperature HP/LP

Design pressure HP/LP

kg/cm (a)

Working pressure HP/LP

kg/cm (a)

Design temperature HP/LP

Max Working temperature


HP/LP

Type of fin

Fins per Inch

Fin materials

10

Type of fin weld

kg/hr
O

C
2
2

C
C

15870/
43230

10180/--

10180/--

124/
100
15/
30
13.5/
20

120

120

16/--

16/--

14/--

14/--

194

194

194

194

194

Fin type

Bare type

Bare type

CS

Resistant
welded

194

Outlet

Flow rate HP/LP

kg/hr

Water outlet temperature HP/LP

Heating surface area HP/LP

C
2

15870/
43230

10180/--

10180/--

176/
124

180

180

1639/
2458

479

479

4.4 Condensate Pre Heater (CPH Non IBR)


i. Material of Construction
a.

Tubes

: SA 210 Gr. A1

c.

Headers

: SA 106 Gr. B

ii. Design Specifications


a. Flue Gas Specifications
TECPRO SYSTEMS LTD, CHENNAI Page 19

0
1

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

Sr.
No.
A

Details

Exhaust gas flow rate

Exhaust gas inlet


temperature

Outlet

Flow rate

Clinker
Cooler

Pre Heater 1
Boiler

Pre Heater 2
Boiler

kg/hr

222355

---

---

126

---

---

222355

---

---

100

---

---

m/s

3.4

---

---

Inlet

Unit

Exhaust gas outlet


temperature
Exhaust Gas Velocity

kg/hr
O

b. Fluid Side Specifications

Sr.
No.
A
1

Detail
s
Inlet
Flow rate

Unit

Clinker
Cooler

Pre Heater 1
Boiler

Pre Heater 2
Boiler

42510

---

---

62

---

---

10

---

---

10

---

---

kg/hr

Water inlet temperature

Design pressure

Max Working pressure

Design temperature

150

---

---

Working temperature

95

---

---

Type of fin

Fin type

Bare type

Bare type

Fins per Inch

Fin materials

CS

1
0

Type of fin weld

Resistant
welded

C
kg/cm2
(a)
kg/cm2
(a)
C
C

TECPRO SYSTEMS LTD, CHENNAI Page 20

0
1

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

Outlet

Flow rate

Water outlet
temperature
Heating surface area

kg/hr

42510

---

---

95

---

---

2458

---

---

C
2

4.5 Steam Drum


i. Material Of Construction
a. Shell
: SA 516 Gr 70
b. Dished Head
: SA 516 Gr 70
c. Nozzles
: SA 106 Gr B
d. Flanges
: SA 105
ii. Design Specifications

Sr.
No.

Pre Heater 1
Boiler
12.5/
3.2
13.5/
3.8

Pre Heater 2
Boiler
12.5/
3.2
13.5/
3.8

190/
136

190/
136

190/
136

194/
142
----

194/
142
----

194/
142
----

mm

1800/
1500

1500/
1500

1500/
1500

mm

26/
16

16/
16

16/
16

Ite
m
Working Pressure HP/LP

Unit
kg/cm (a)

Design Pressure HP/LP

kg/cm (a)

Working Temperature HP/LP

Design Temperature HP/LP

Shell

Shell Internal Diameter HP/LP

Shell Thickness HP/LP

C
C

----

TECPRO SYSTEMS LTD, CHENNAI Page 21

Clinker
Cooler
12.5/
3.2
13.5/
3.8

TECPRO SYSTEM LIMITED


AMBUJA CEMENT LTD

mm

Steam drum shell length


HP/LP
Normal water level HP/LP

Dished Head HP/LP

----

Type of Dished Head HP/LP

Dished Head Internal diameter


HP/LP

mm

Dished end thickness HP/LP

mm

Number of Manholes HP/LP

Location of Manhole HP/LP

TECPRO SYSTEMS LTD, CHENNAI Page 22

~5000

----

~5000

100 mm Below 100 mm Below 100 mm Below


centerline/
centerline/
centerline/
50 mm Below 50 mm Below 50 mm Below
centerline
centerline
centerline
----

----

----

1800/
1500

Ellipsoidal
head
1500/
1500

Ellipsoidal
head
1500/
1500

26/
16

16/
16

16/
16

2/2

Ellipsoidal head

Nos

~5000

On dished end On dished end On dished end