BX10 Integrated Service Platform


INSTRUCTION MANUAL

Ver2.1

BX10 Integrated Service Platform


Released in: Nov., 2009
There will be no further notice on the periodical amendment of this publication, and
the amendment will be supplemented to the publication.
Thank you for selecting BX10 Integrated Service Platform

Table of Contents

Safe Operation Notice................................................................................................ 1


Chapter One BX10 Integrated Service Platform.................................................. 1
1.1 Product Overview......................................................................................... 1
1.2 Product Features......................................................................................... 1
1.3 Product Functions......................................................................................... 2
1.4 Module Allocation......................................................................................... 2
1.5 Typical Applications..................................................................................... 3
1.6 Technical objectives..................................................................................... 3
Chapter Two Equipment Introduction.................................................................... 8
2.1 Equipment Models.....................................................................................

2.2 power board................................................................................................... 9


2.3 MCUS.......................................................................................................

11

2.4 NMC.......................................................................................................... 18
2.5 E1PS.......................................................................................................... 18
2.6 CHUPS....................................................................................................... 21
2.7 DATA.......................................................................................................... 35
Chapter Three Outgoing Lines...........................................................................

44

3.1 2M Outgoing Lines of MCUS................................................................

44

3.2 2M outgoing lines of E1PS....................................................................... 46


3.3 VF Cable...................................................................................................

52

3.4 E/M VF Cable............................................................................................ 54


3.5 10BASE-T Cable.....................................................................................

56

3.6 RS232/485 Data Cable.............................................................................. 58


3.7 V35 Data Cable......................................................................................... 59
3.8 V35 and 10BASET Data Cable................................................................ 61
3.9 RS232/485 Monitoring Cable.................................................................... 63
3.10 -48 Power Cable..................................................................................... 64

1 , 1

BX10 Integrated Service Platform

Safe Operation Notice


This equipment performs well when being used as designed, while the artificial
harm or damage should still be avoided.

Read this manual carefully and keep it well for future reference.
Keep the equipment away from water source or damp place.
Don't place anything on the power cable and keep it out of the reachable scope.
Don't knot or encase the cable to avoid fire hazard.
Make regular inspection to ensure that the power connections and the connecting
pieces of other equipment are reliably connected.
Pay attention to the markup on the wiring terminal when connecting the power
cable (the black end is connected with the negative polarity, the red is connected with
the straight polarity.
The power supply must meet the following conditions:
DC -48V-36V -72V
AC220V220V10, 50Hz
Unplug the power immediately and contact the After-sale Service Department of
the company in the following cases.
Water penetration;
Crash of the equipment or casing;
Abnormal operation or changed performance;
Bad smell, smoke or noise of the equipment.
Please keep the equipment clean and wipe it with soft cotton cloth if necessary.
Leave the ventilator open.
Do not repair the equipment by yourself unless it is clearly indicated in the Manual.

1 , 1

BX10 Integrated Service Platform

2 , 59

BX10 Integrated Service Platform

Chapter One BX10 Integrated Service Platform


1.1 Product Overview
BX10 intelligent Integrated Service Platform integrates the digit/analogue access,
multiplexing, cross connection, transmission and protocol conversion functions with
the powerful cross matrix in the core. It constructs a unified platform of serial
equipment in a standard structure by combining the service types of the access
networks. It provides GV/GE/DXC/PCM and mixed functions of all modules on
such platforms as public power supply, network administration, cross connection and
motherboard, and it integrates broadband and narrowband networks.

Through the SNMP, the communication state of the whole net could be
monitored in real time.

1.2 Product Features


It integrates such functions as digit/analogue access, multiplexing, cross
connection, transmission and protocol conversion;

There are quite a few models and the 4U, 2U and 1U models are compatible
with each other for convenient capacity-expansion;

Rich interfaces: POTS, 10Base-T, V.35, RS232, RS485, etc;

Flexible layout, plugging into any slot and free selection of interface cards;

Hot plug & pull;

Power supply warm standby

Open bus and rich user interfaces for adding new services;

Flexible networking: chain, tree, star and ring-type networked;

Intelligent network administration system:

human-based management,

accurate localization of fault, distributed management, etc;


64E1 crossing and supporting CAS signaling crossing;

Standard machine frame compatible with BX stand-alone plugboards.

1 , 40

BX10 Integrated Service Platform

1.3 Product Functions


1 Voice access via diversified signaling interfaces:
Automatic telephone, E/M interface, 2W/4W audio, etc.
2

Data access via diversified data interfaces:

10Base-T, V.35, RS232/485, etc.


Notice: RS232 data port should be well grounded or serial port isolator is added
so that RS232 data port will not be burnt out.
3 Optical transmission interfaces, including PDH:
PDH optical fiber terminal: 4E1.
4 Cross connection, E1 plugboard structure:
64E1 crossing and supporting CAS signaling crossing.
5 Converter pool:
10Base-T, V.35 converter pool.
6

Centralized network administration:

Whole net monitoring and SNMP support.


1.4 Module Allocation
1. MCUS provides 4 E1 interfaces and Ethernet monitoring card could be
adopted to realize whole net monitoring.
2. The voice channels are allocated by two and 8 channels may be allocated to
each board at most, 104 channels for the 4U model in full.
3. The data channels (10/100Base-T, V.35) are allocated by one and 4 channels
could be allocated to one board at most, 52 channels for the 4U model in full.
4. The RS232 485 data channels are allocated by two and 8 channels
may be allocated to each board at most, 104 channels for the 4U model in full.
5. Each board provides 8 E1 interfaces (64 for 4U model at most) for realizing
64xE1 time slot crossing and signaling crossing.
1.5 Typical Applications

MAN construction

2 , 59

BX10 Integrated Service Platform

Large client integrated services access

3-in-1 network construction

Intelligent zone construction

DDN network extension

Mobile base station construction

Development of telecommunications services by making use of the existing


CATV network

Construction of the wiring network layer of the access network

Rural telecom network reconstruction

Replacement of the PDH and SDH optical transmission equipment

Emergency Communication

Information network construction at armies

1.6 Technical objectives


Interface type
POTS remote
interface

Technical Indicators
Encoding mode

A-law

Bit rate

64Kbps

DC loop resistance

2000

(Max.)
Effective

300-3400Hz/600

transmission
bandwidth
Frequency characteristics
300Hz400Hz

-0.3~ -0.1dB

400Hz2400Hz

-0.2~ 0.1dB

2400Hz

0~0.7dB

3400Hz
Unbalanced to earth
300Hz600Hz

40dB

600Hz3400Hz

46dB

Idle channel noise

<-67dB

3 , 59

BX10 Integrated Service Platform

Ringing current
POTS local
interface

253Hz, 7515V

voltage
Encoding mode

A-law

Bit rate

64Kbps

DC loop resistance

2000

(Max.)
Effective

300-3400Hz/600

transmission
bandwidth
Frequency characteristics
300Hz400Hz

-0.3~ -0.1dB

400Hz2400Hz

-0.2~ 0.1dB

2400Hz

0~ 0.7dB

3400Hz
Unbalanced to earth

Group-path
interface

300Hz600Hz

40dB

600Hz3400Hz

46dB

Idle channel noise

<-67dB

Impedance

75 unbalance /120 balance

matching
Interface code

HDB3

Nominal bit rate

2048Kb/s50ppm

and allowance
Nominal wave form

2.37V0.237V/75(unbalance)

amplitude
Insertion loss: the attenuation is 0-6dB at 1024KHz
Audio
interface

Total distortion

Conforming to ITU-T G.713

Frequency

Conforming to ITU-T G.713

Level

Conforming to ITU-T G.713

Effective

300~3400 Hz/600

transmission
bandwidth
Audio transmission

2W/4W

mode
4 , 59

BX10 Integrated Service Platform

E&M

2W receive

0dBr/600

2W transmit

+17.5dBm, adjustable)
-3.5dBr/600

4W receive

0dBm, adjustable
-14dBr/600

4W transmit

+17.5dBm, adjustable
+4dBr/600
-27.5dBm~

Level

+4dBm, adjustable
0.5dBm

adjustment

-31.5dBm~
-14dBm~

step
Overload level

+3.14dBm

Internal resistance

When put to earth 2010%

Sampling frequency

When in open circuit 100 K


500Hz

interface
Pulse distortion

2.5ms

Clock rate

500Hz 8KHz

Encoding rule

1 when in open circuit; 0 when put to

Resistance

earth
600

M-line

transmit)
5mA

sensitivity
E-line
V.35 interface

-14dBm~

detection
output

2W, 4W receive, 4W

50mA

current
Nominal bit rate

N64k N is 1~31

Port mode

DCE/DTE

Framing or non-framing, internal or external clock or circuit


10BaseT

(optional)
Supported protocol

Conforming to IEEE 802.3

interface

Physical interface

RJ45

Interface rate

N64k N is 1~31

BX120

System capacity

4E1

Optical

Optical transmitting

-5~ -12dBm

power

5 , 59

BX10 Integrated Service Platform

module

Optical

reception

sensitivity
Type of

optical

fiber connector
Input impedance
Signaling
mode
Power supply

-36dBm
FC
75/120

The 16th time slot channel associated signaling, conforming


to ITU-T G.732
Power source

-48VDC

Power consumption

220VAC 165V~265V
<= 3w (for audio multiplexing)

-36V~-72V or

The peak power output of the ringing current module: 30W


Machine case
structure
Working
environment

19" wide and 4U, 2U or 1U high


16 slots in all, of which 14 are in common use
Temperature

5~50

Humidity

90%

Air pressure

86~106Kpa

6 , 59

BX10 Integrated Service Platform

Chapter Two Equipment Introduction


2.1 Equipment Models
There are quite a few models adopting the plugboard architecture and the 4U,
2U and 1U models are compatible with each other for convenient capacityexpansion;
1 4U model (BX10-4U):
4U: height; 19: width; 300mm: depth.
PWR
48V
+5V
-5V
RING

MCUS
NET
RUN
LINK
MRUN
TEST
MA
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4

CHUPS

DATA

CHUPS

DATA

E10PS

E10PS

E10PS

E10PS

CHUPS

DATA

CHUPS

DATA

1
2
3
4
5

TD1
RD1
TD2
RD2
TD3

1
2
3
4
5

TD1
RD1
TD2
RD2
TD3

PWR
TXD
RXD
LINK
ERR

PWR
TXD
RXD
LINK
ERR

PWR
TXD
RXD
LINK
ERR

PWR
TXD
RXD
LINK
ERR

1
2
3
4
5

TD1
RD1
TD2
RD2
TD3

1
2
3
4
5

TD1
RD1
TD2
RD2
TD3

6
7
8

RD3
TD4
RD4

6
7
8

RD3
TD4
RD4

RLS
FLA
AIS
RA

RLS
FLA
AIS
RA

RLS
FLA
AIS
RA

RLS
FLA
AIS
RA

6
7
8

RD3
TD4
RD4

6
7
8

RD3
TD4
RD4

PWR

E1PS
RUN
PWR
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4
FLA5
RLS5
FLA6
RLS6
FLA7
RLS7
FLA8
RLS8

48V
+5V
-5V
RING

MONITOR

It applies to the central office end with 16 slots, 14 of which are for functional
boards and 2 for power boards in warm standby.

RD3
TD4
RD4

TD1
RD1
TD2
RD2
TD3

PWR

RD3
TD4
RD4

TD1
RD1
TD2
RD2
TD3

DATA

-5V

RD3
TD4
RD4

DATA

E10PS

E10PS

1
2
3
4
5

TD1
RD1
TD2
RD2
TD3

1
2
3
4
5

TD1
RD1
TD2
RD2
TD3

PWR
TXD
RXD
LINK
ERR

PWR
TXD
RXD
LINK
ERR

6
7
8

RD3
TD4
RD4

6
7
8

RD3
TD4
RD4

RLS
FLA
AIS
RA

RLS
FLA
AIS
RA

E10PS

MCUS

TD1
RD1
TD2
RD2
TD3

CHUPS

NET
RUN
LINK
MRUN
TEST
MA
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4

DATA

DATA

MONITOR

RING

CHUPS

E1PS

+5V

NET
RUN
LINK
MRUN
TEST
MA
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4

RUN
PWR
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4
FLA5
RLS5
FLA6
RLS6
FLA7
RLS7
FLA8
RLS8

48V

MCUS

CHUPS

1
2
3
4
5
6
7
8

DATA

2 2U model (BX10-2U):
48V

ON

E10PS

CHUPS

+5V

OFF
DATA

CHUPS

PWR
TXD
-5V
RXD
LINK
RING
ERR

1
2
3
4
5

TD1
RD1
TD2
RD2
TD3

1
2
3
4
5

TD1
RD1
TD2
RD2
TD3

RLS
FLA
AIS
RA

RLS
FLA
AIS
RA

6
7
8

RD3
TD4
RD4

6
7
8

RD3
TD4
RD4

MONITOR

2U:
height; 19: width; 300mm: depth.
It applies to the remote end with 6 slots. The power board does not utilize the
slot and no warm standby is provided.
3 1U model (BX10-1U):
BX10

7 , 40

ON

DATA

PWR
TXD
RXD
LINK
ERR

RS232/RS485

OFF

E1PS
RUN
PWR
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4
FLA5
RLS5
FLA6
RLS6
FLA7
RLS7
FLA8
RLS8

PWR
48V
+5V
-5V
RING

BX10 Integrated Service Platform

1U: height; 19: width.


10 service slots (6 data slots and 4 voice slots). The data interfaces, such as
V.35, 10/100Base-T, Rs232 and Rs485, and voice interfaces are supported; one main
service slot, and the main service may be provided through 1 E1, 2 E1, 3 E1, 4 E1
and 120 optical terminal card; one network layer management card ( Ethernet
Interface management card or Rs232/485 interface management card).
2.2 power board
1

4U power board :

It applies to 4U machine case and 2 power boards could be plugged in for


warm standby. There is power indicator on the front panel, indicating the operating
state of the power supply.

PWR
48V
+5V
-5V
RING

8 , 59

BX10 Integrated Service Platform

A.4U no-ring current power board BX10-PWRS-4UL


Input: DC 36 ~ 72V
Function: DC/DC switchover for powering the system.
Output: +5V, -5V, -48V Power feed.
b. 4U remote power board BX10-PWRS-4UR
Input: DC 36 ~ 72V
Function: DC- 48V is converted to AC 75V ringing current for powering the
system.
Output: +5V, - 5V, ringing current, - 48V power feed.
2

2U power board :

It applies to 2U machine case and only one power board can be plugged (no
warm standby).

9 , 59

BX10 Integrated Service Platform

a.

2U no-ring current power board BX10-PWRS-2UL


Input: DC 36 ~ 72V

AC 220V

Function: power the system through DC/DC switchover.


Output: +5V, - 5V,- 48V power feed.
b. 2U remote power board BX10-PWRS-2UR
Input: DC 36 ~ 72V

AC 220V

Function: DC- 48V is converted to AC 75V ringing current for powering the
system.
Output: +5V, - 5V, ringing current, - 48V power feed.
2.3 MCUS
Functional Description:
1.

It is the system control center for monitoring and


resource allocation.

2.

It contains the very-large-scale integrated circuit with


built-in 20482048 cross matrix for realizing the free
crossing of 64 E1 time slots.

3.

The system conducts self-check automatically and the


problems will be reported in time for fault location.

4.

Network monitoring card can be provided to monitor the


whole net, and the monitoring channel time slots and
backup bits are optional.

5.

There are four built-in E1 interfaces.

Functional Interfaces:

10 , 59

BX10 Integrated Service Platform

MCU
S

Layout

Indicator

Address switch

Side wheel switch


1

Monitoring port 1

Reset switch

Program switch

Resistance

Setup

E1

E1 interface

1. E1 interfaces:
1)

Position: (J1) DB37 hole-type plug.

2)

Interface: balance -

DB37 hole-type plug, unbalance

- CC4A coaxial socket


3)

Providing 4E1 interfaces and refer to the Appendix for

the outgoing lines.


4)

Supporting balance and unbalance modes.

5)

Supporting multiple signaling modes:


CAS

the subscriber signaling are crossed

automatically.
CCS: in this mode, TS16 time slot could be used to
11 , 59

BX10 Integrated Service Platform

transmit the user services.


6)

Supporting CRC - 4 test.

7)

Providing monitoring channels: the time slots and backup

bits are optional.

2. Monitoring interface:
1 Position

(J4) DB9 hole-type plug, RS232/485

monitoring; (J5) RJ45 plug, Ethernet monitoring.


2 See "Appendix: Outgoing lines of monitoring ports"
for the outgoing lines of each monitoring port.
3

The RS232 monitoring transmission rate is 9600bps,

and the transmission distance is 15m.


4

The RS485 monitoring transmission rate is 9600bps,

and the transmission distance is 800m.


5

The

Ethernet monitoring

MCUS
100m.

3.

NET
RUN
LINK
MRUN
TEST
MA
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4

Indicator lights:

MONITOR

12 , 59

transmission rate is

10/100Mbps

and

the

transmission

distance

is

BX10 Integrated Service Platform

4. Switch setting:
1

Reset button:

Position: S21.
Function: press it to reset CPU.
2

Program switch:

Position: S20.
Function: program selection.
Set the short circuitor near S20
3

Side tumble switch:

Position: JP5

SW1

OFF

ON

ON

OFF

SW2

OFF

OFF

ON

ON

LED alarm indicator


RLS

AIS
13 , 59

MFLA

CMFLA

BX10 Integrated Service Platform

FLA
SW3

RA

MRA

CMA

RS232 monitor mode

RS485 monitor mode

ON

OFF

SW4

Reserved

See the following table to interpret the indicator lights:


Name

of

Meaning

indicator
light
NET

Constant on: network monitoring card is provided; constant off:

RUN

no network monitoring card is provided.


Flicker: MCUS is in working order; no flicker: MCUS is out of

LINK

working order
Constant on: the net wire connection of the network monitoring
card is normal; constant off: abnormal connection (the standard

MRUN

configuration is invalid)
Flicker: the network monitoring card is in working order; no
flicker: abnormal operation (the standard configuration is

TEST

invalid)
Reserved

MA

Reserved

RLS1-4

Constant on: 2M signal reception loss; off: normal 2M signal

FLA1-4

reception
constant on: Out of frame of 2M signal frames; off: normal

AIS1-4

reception of 2M signal frames


constant on: Reception of all "1" 2M signals; off: normal 2M

RA1-4

signal reception
constant on: Alarm for the 2M signal reception at the opposite

MFLA1-4

end; off: normal 2M signal reception at the opposite end


constant on: Out of step reception of 2M signal multi-frames;

MRA1-4

off: normal reception of 2M signal multi-frames


constant on: Out of step reception of 2M signal multi-frames at
the opposite end; off: normal reception of 2M signal multi-

14 , 59

BX10 Integrated Service Platform

frames at the opposite end


CMFLA1-4

constant on: Out of step reception of 2M signal CRC4 multi-

CMRA1-4

frames; off: normal reception of 2M signal CRC4 multi-frames


constant on: Out of step reception of 2M signal CRC4 multiframes at the opposite end; off: normal reception of 2M signal
CRC4 multi-frames at the opposite end

Notice: 1-4 refer to the four 2M ports on the backboard: 2M 1- 2M4, and only two
lights ( RLS1 FLA1) for the alarm of the first E1 are concerned in the standard
configuration and others are reserved. Other alarm information could be viewed
through the thumb wheel dial (SW).

4 Address switch:

*Note: The abbreviated drawing of JP1 and JP2 switches on MCUS is

provided

Position: JP1 and JP2 top tumble switches.


Function: JP1 is for network address setting and JP2 is for unit address
setting. ON is "1" and OFF is "0".
5

RS485 Resistance:

Position: S16 S17 S18

S19.

Function: Access RS485 matched resistance at side Y and not access


15 , 59

BX10 Integrated Service Platform

matched resistance at side N.


6

E1 port setting:

A. Balance mode setting:

S5-S12, it is unbalance mode if short circuitor is applied, otherwise, it is


balance mode.
B. Interface impedance setting:

S1-S4: it is 75ohm at the side printed with 75 and 120ohm at the side
printed with 120.
2.4 NMC
Functional Description:
1.

Realizing whole net monitoring (compatible with BX06 equipment)


through intercommunication between BX10 equipment.

2.

If this card is not added to MCUS, only local monitoring can be


realized.

3.

Supporting Ethernet, RS232, RS485 monitoring.

4.

Supporting SNMP.

16 , 59

BX10 Integrated Service Platform

5.

Refer to "BXView 4 Network Administration User Manual" for the


network administration software.

2.5 E1PS
Functional description
1.

Each board provides 8 channels, and the 4U model


could provide 8 boards to realize 64 channels and to
realize the complete crossing of 64E1 time slots. The
2U model could provide 5 boards to realize 44 channels
(the main control board may provide 4 channels).

2. E1 interface supports the CAS and CCS signaling modes.


3. E1 interface supports the balance and unbalance modes.
Functional Interfaces:

Indicator

Side wheel switch


Reset switch

E1 1

E1 port setup 1

E1

E1 Interface

E1 interface
1 Position: (J5) DB62 hole-type plug.

17 , 59

BX10 Integrated Service Platform

2 Interface: balance -

DB62 hole-type plug,

unbalance- CC4A coaxial DB62 hole-type plug.


3 Providing 8E1 interfaces and refer to the Appendix
for the outgoing lines.
4 Supporting balance and unbalance modes.
5 Supporting multiple signaling modes:
CAS

the subscriber signaling are crossed

automatically.
CCS: in this mode, TS16 time slot could be used to
transmit the user services.
6

Supporting CRC-4 verification..


Providing monitoring channels: the time slots and

backup bits are optional.

2. E1 port setting:
A. Balance mode setting:

18 , 59

BX10 Integrated Service Platform

S4-S19 it is unbalance mode is short circuitor is applied to side N or


balance mode is short circuitor is applied to side Y.
B. interface impedance setting:

S20-23, S24-S27, it is 75ohm at the side printed with 75 and 120ohm at


the side printed with 120.

4. Indicator lights

E1PS
RUN
PWR
FLA1
RLS1
FLA2
RLS2
FLA3
RLS3
FLA4
RLS4
FLA5
RLS5
FLA6
RLS6
FLA7
RLS7
FLA8
RLS8

19 , 59

BX10 Integrated Service Platform

2.6 CHUPS
The voice services provided by BX10 Integrated Service Platform are realized
by the CHUPS and corresponding service interface cards. The CHUPS is in charge
of data send-receive, data processing and network management information
arrangement, and the interface cards provides interfaces to the voice service
equipment, such as telephone sets, magnet telephone sets, exchanges, etc. The
service interface cards convert the real line signaling and voice signals sent from
different equipment to digital signals and send them to the CHUPS, where they shall
be processed and sent to the opposite end. At the opposite end, such signals will be
restored to the real line signaling and analog speech signals that could be identified
by the user equipment in order to complete the call duration and voice transmission.
The service interface cards include the 2W4WCHUC, CHUFXOC, CHUFXSC,
EMC, MAC and CARC according to the services provided.
The indicator lights on the panel are as follows:

CHUPS
RUN
1
2
3
4
5
6
7
8

The indicator lights on

the front panel of the CHUPS


20 , 59

BX10 Integrated Service Platform

are defined as follows:


RUN: it flickers when the program runs normally and it is off when the
program does not run normally.
1-8: the voice channel is utilized when the light is constantly on, and it is idle
when the light is off.
Each board could provide the access to 8 channels of voice service.
Classification:
CHUPS BX10_CHUPS
2W4WCHUC BX10_2W4WCHUC
CHUFXOC BX10_CHUFXOC
CHUFXSC BX10_CHUFXSC
EMC BX10_EMC
MAC BX10_MAC
CARC

BX10_CARC

Applications:
CHUPS: it provides various services with cards plugged and it could provide
8 voice channels at best.
2W4WCHUC: each card provides 2 2W/4W voice channels with adjustable
attenuation as well as the independent VF channel.
CHUFXOC and CHUFXSC: Automatic station set signalling card
common telephone interface is provided, and CHUFXOC is adopted for the
connection with the exchange and CHUFXSC is used for the connection with the
user telephone. Each card provides 2 ways of 2W voice channels with fixed
attenuation.
EMC: provide one way E/M signalling interface (1E1M- 2E2M, type 1-5)
and one way 2W/4W voice channel with adjustable attenuation.
MAC: provide magnet telephone interface. Each card provides one channel.
CARC: Provide the interface for conversion from 2W carrier wave interface
2100hz signaling to 25Hz ringing current. One channel for each card.

21 , 59

BX10 Integrated Service Platform

Functions:
BX10_CHUPS

Service configuration through communication with the network management


system.

Data transmission via communication with the bus.

Processing voice and signaling information.

Supplying power to each service card, conducting data exchange and providing
outgoing lines to various service interfaces.

BX10_2W4WCHUC

Realizing the switchover between digital signals (A-law,


PCM) and analog voice signals.

Providing 2 VF channels or two 2/4W analog private line


interface channels without signaling.

The 2/4W switchover of each VF channel could be set


separately.

Realizing the loop-back of all VF channels under the


control of loop-back signals.

Providing the line protection function to prevent the


interfaces from being damaged by lightning or the clash
between the subscriber line and other power lines.

Adjusting the transmission level of the receive side and transmit

side of the 2/4W respectively through the jumpers.


BX10_CHUFXOC
Providing two channels of 2W telephones with automatic central office end
signaling.
22 , 59

BX10 Integrated Service Platform

Serving as the common analog station set to restore the remote off-hook and
hang-up signals.

Restoring the remote end dial pulses.

Detecting the ring signals on the exchanger subscriber line, converting them to
digital signaling and supplying them to MCUS.
Displaying the utilization of channels.

Supporting the function of "Calling Identity Delivery".

BX10_CHUFXSC
Providing two channels of 2W telephones with automatic station set remote
signaling.
Being equivalent to the subscriber module of exchange and providing station set
feed and ring current.
Detecting the on-hook, off-hook and pulse dialing signals from the subscriber
line, converting them to the digital signaling and supplying them to MCUS.
Indicating the working order of the user port.
The maximum allowable loop resistance is 2000.

BX10_EMC

Completing the switching from E & M signaling to digital


signaling and supplying the digital signaling to the MCUS.

Providing one channel of E & M (from 1E1M to 2E2M)


signaling port.

Providing one 2/4W voice channel with adjustable


attenuation.

23 , 59

BX10 Integrated Service Platform

Each port could be configured to Type I, II, III, IV or V


E& M interface.

Providing the port status indication.

BX10_MAC
Completing the switching from magnet signaling to digital signaling;
Providing one channel of magnet telephone interface;
Providing the port status indication.

BX10_CARC

Detecting and restoring the carrier wave in-band 2100Hz


signaling;

Detecting and restoring the 25Hz ring current signaling of


the magnet interface;

Providing one channel of 2W carrier wave switching


interface at the same time;

Indicating the port status.

Operating Instructions:
The CHUPS will provide voice service jointly with corresponding service
interface cards, thus the operating instructions are introduced by the service interface
card.
BX10_2W4WCHUC

2W/4W VF channel setting switch


Setting the channels to work in 2W or 4W mode.

VF channel send and receive relative level setting switch


2W/4W mode selector

The voice channel may be set to 2W or 4W work mode by changing the

24 , 59

BX10 Integrated Service Platform

position of the mode conversion switch. The work mode of voice channel 1 may be
set through S5 and that of voice channel 2 through S6, as shown below:
Channel 1: 4W mode

Channel 2: 4W mode

S5

S6

Channel 1: 2W mode

Channel 2: 2W mode

S5

S6

Relative level setting


switch
For each VF channel, there are transmit level setting switches and receive
level setting switches in two groups (24-pin jumpers) (channel 1 is corresponding to
S1 and S2; channel 2 is corresponding to S3 and S4), the regulating range is 031.5dB, and the regulating step is 0.5dB.
The attenuator is composed of 6-section resistor network and the attenuation
of each section is 0.5db, 1db, 2db, 4db, 8db, 16db respectively. Each section is
corresponding to two lines of contact pins and the attenuator of certain section is
switched on if the pins are plugged into the lower part of the switch. The sum of the
attenuation of all sections is the attenuation of the whole attenuator.
The 2W4WCHUC is in 2W mode in default, whose transmit level is 0dBr
and receive level is - 3.5dBr. The voice channel setting may be changed as follows:

25 , 59

BX10 Integrated Service Platform

16dB

16dB

8dB

8dB

4dB

4dB

2dB

2dB

1dB

1dB

0.5dB

0.5dB

R S1

S2

2W receive level attenuation setting (attenuation 4dB); 2W transmit level


attenuation setting (attenuation 14dB);

16dB

16dB

8dB

8dB

4dB

4dB

2dB

2dB

1dB

1dB

0.5dB

S1

0.5dB

S2

4W receive level attenuation setting (attenuation 0dB); 4W transmit level


26 , 59

BX10 Integrated Service Platform

attenuation setting (attenuation 0dB);


(Note: R represents the receiving end, T represents the transmitting end. The
setting of another voice channel is similar and S3 and S4 will be set
correspondingly.)
The transmit and receive levels of 2W/4W is suggested adopt the default setup.

BX10_FXOC
It has level adjusting switches at the transmit and receive directions. There are 4
jumpers in the vertical direction, forming the upper group and lower group. The
upper groups are regulating switches in the transmitting direction and the lower
groups are the regulating switches for the receiving direction. 4dB interface level
attenuation could be added to corresponding direction via the regulating switches.
See the following figures for the position of the short circuitor and it is 0dB level
attenuations.

Transmitting direction

Receiving direction

When the short circuitor is plugged on 3, 4dB interface level attenuation is


added to the transmit direction of voice channel 1; if it is plugged on 2, 4dB interface
level attenuation is added to the receive direction of voice channel 1. When the short
circuitor is plugged on 7, 4dB interface level attenuation is added to the transmit
direction of voice channel 2; if it is plugged on 6, 4dB interface level attenuation is

27 , 59

BX10 Integrated Service Platform

added to the receive direction of voice channel 2.


The indicator lights on the panel indicate the channel status.
BX10_FXSC
It has level adjusting switches at the transmit and receive directions. There are
4 jumpers in the vertical direction, forming the upper group and lower group. The
upper groups are regulating switches in the transmitting direction and the lower
groups are the regulating switches for the receiving direction. 4dB interface level
attenuation could be added to corresponding direction via the regulating switches.
See the following figures for the position of the short circuitor and it is 0dB level
attenuations.

Transmitting direction

Receiving direction

When the short circuitor is plugged on 3, 4dB interface level attenuation is


added to the transmit direction of voice channel 1; if it is plugged on 2, 4dB interface
level attenuation is added to the receive direction of voice channel 1. When the short
circuitor is plugged on 7, 4dB interface level attenuation is added to the transmit
direction of voice channel 2; if it is plugged on 6, 4dB interface level attenuation is
added to the receive direction of voice channel 2.
The channel status is shown through the panel indicators.
BX10_EMC
The meanings of the panel indicator lights are the same as that of CHUFXOC
and CHUFXSC.
28 , 59

BX10 Integrated Service Platform

EMC decides to use which one of the five types of cards through jumper
switch.
The way of setting single channel of EMC is given below and it is the same
for the remote end. Take 1E1M as an example, A3, A4, A6, A7, A8 are the common
control switches of E1M1 and E2M2. It is the same for the 2E2M setting.
A. Set it to the first type of EM: apply short circuitor to A3; do not apply short
circuitor to A4, A6, A7 and A8; plug short circuitor into the lower half of SW1. Line
E and line F of this board are connected with line E and line M of the exchange
respectively, and E is connected with M, M with E and SB with SG when connecting
with user equipment, as shown in the right figure:

SG

GND

A8
CLOSE

A3 +48

SB

-48

A4

A7

GND

A6

The short circuitor of SW1 is set as follows:

M
-48

GND
SW1

B. set it to the second type of EM: apply short circuitor to A7; do not apply short
circuitor to A3, A4, A6 and A8; plug short circuitor into the lower half of SW1. Line
E and line M of this board are linked with line E and line M of the exchange directly,
and SG and SB are connected with the SG and SB of the exchange directly. When

29 , 59

BX10 Integrated Service Platform

connecting with the user equipment, E is connected with M, M is connected with E


and SB and SG lines are connected directly, as shown below:

SG

GND

A8
CLOSE

A3 +48

SB

-48

A4

GND

A6

A7

The short circuitor of SW1 is set as follows:

M
-48

GND
SW1

C. set it to the third type of EM: apply short circuitor to A3 and A7; do not apply
short circuitor to A4, A6 and A8; plug short circuitor into the lower half of SW1.
Line E and line M of this board are linked with line E and line M of the exchange
directly, and SG and SB are connected with the SG and SB of the exchange directly.
When connecting with the user equipment, E is connected with M, M is connected
with E and SB and SG lines are connected directly, as shown below:

GND

A8
CLOSE

SG

A3 +48

SB

-48

A4
30 , 59

A7

GND

A6

BX10 Integrated Service Platform

The short circuitor of SW1 is set as follows:

M
-48

GND
SW1

D. set it to the fourth type of EM: apply short circuitor to A6; do not apply short
circuitor to A3, A4, A7 and A8; plug short circuitor into the upper half of SW1. Line
E and line M of this board are linked with line E and line M of the exchange directly,
and SG and SB are connected with the SG and SB of the exchange directly. When
connecting with the user equipment, E is connected with M, M is connected with E
and SB and SG lines are connected directly, as shown below:

GND

A8
CLOSE

SG

SB

-48

A3 +48

A4

The short circuitor of SW1 is set as follows:

31 , 59

A7

GND

A6

BX10 Integrated Service Platform

M
-48

GND
SW1

E. Set it to the fifth type of EM: apply short circuitor to A3; do not apply short
circuitor to A4, A6, A7 and A8; plug short circuitor into the upper half of SW1. Line
E and line M of this board are linked with line E and line M of the exchange directly,
and SG and SB are connected with the SG and SB of the exchange directly. When
connecting with the user equipment, E is connected with M, M is connected with E
and SB and SG lines are connected directly, as shown below:

SG

GND

A8
CLOSE

A3 +48

A4

The short circuitor of SW1 is set as follows:

M
-48

GND
32 , 59

SW1

SB

-48

A7

GND

A6

BX10 Integrated Service Platform

The exact arrangement of E/M is also shown on the sick screen print of the
EMC.
Notice:
The EMC may be set to certain type by strictly following the aforementioned
method and it should be checked carefully. The machine board may be burnt if the
short circuitor is wrongly plugged! It is strictly prohibited to plug and pull the EMC.

BX10_MAC
Like 2W4WCHUC, MAC also has transmit level setting switches and receive
level setting switches (24 pin jumpers-S1, S2). The transmit level and the receive
level could be adjusted respectively and the way of level setting is the same as that
for 2W4WCHUC (Note: only 2W mode is provided and there is no 4W mode)
BX10_CARC
Like 2W4WCHUC, CARC also has transmit level setting switches and
receive level setting switches (24 pin jumpers-S1, S2). The transmit level and the
receive level could be adjusted respectively and the way of level setting is the same
as that for 2W4WCHUC (Note: only 2W mode is provided and there is no 4W
mode)

2.7 DATA
Classification: DATA, 10BASE-T Ethernet interface card, RS232/485 data
interface card, V.35 synchronous data interface card.

DATA

Functional Description:
1. Each DATA provides four slots for V.35 data interface card, 10BASE - T Ethernet
interface card and RS232/485 data interface card.
2. The DATA does not provide any interface, but it may be added with interface
cards. For instance, it could provide V.35 interface with v.35 data interface card
33 , 59

BX10 Integrated Service Platform

plugged, RS232/485 data interface with RS232/485 interface card plugged and
10BASE-T Ethernet interface with 10BASE-T Ethernet interface card plugged. The
above three kinds of cards may be plugged into the same data interface board. The
data board could provide four V.35 interfaces, four 10BASE - T Ethernet interfaces
and eight RS232/485 interfaces at most.
Notice: RS232 data port should be well grounded or serial port isolator is
added so that RS232 data port will not be burnt out.
3. V.35 data interface and 10BASE-T Ethernet interface could be set to N64k
(n=1-31) dynamic data channel. RS232/485 data interface may be set to 64K data
channel.
Functional Interfaces:

Slot

Interface

N
ot

e:

if
D
B

6R
J45 switch is applied to V.35,

RS232 or RS485 interface, the

DATA could provide 10Base-T

interface.

34 , 59

BX10 Integrated Service Platform

Description of indicator lights


1

Plug V.35 synchronous data interface card into the DATA


RU
N

flicker

light

RX
D1

L/D
1

channel

receive

off
flicker

program run
channel 1 is

data

receiving

channel 1 transmit

D2

L/D
2

channel

off
flicker

D3

L/D

data
idle
channel 1 is
transmitting

receive

off
flicker

data

data
idle
channel 2 is
receiving

channel 2 transmit

off
flicker

data

RX

normal
program run
abnormal

data

RX

Program run indicator

data
idle
channel 2 is
transmitting

Channel 3 receive

off
flicker

data

data
idle
channel 3 is
receiving

Channel 3 transmit
data

off
flicker

data
idle
channel 3 is
transmitting
data

35 , 59

BX10 Integrated Service Platform

RX
D4

L/D
4

Channel 4 receive

off
flicker

data

idle
channel 4 is
receiving

Channel 4 transmit

off
flicker

data

data
idle
channel 4 is
transmitting

off

data
idle

2. Plug RS232/485 data interface card into the DATA


RUN

Program run indicator

flicker

normal

off

program run
abnormal

flicker

program run
channel 1 is

light

RXD1

channel

receive

data

L/D1

channel

receiving

receive

off
flicker

data

RXD2

receiving

Channel 3 receive

off
flicker

data

L/D2

data
idle
channel 3 is
receiving

Channel 4 receive

off
flicker

data

RXD3

data
idle
channel 2 is

data
idle
channel 4 is
receiving

Channel 5 receive
data

off
flicker

data
idle
channel 5 is
receiving
data

36 , 59

BX10 Integrated Service Platform

L/D3

off
flicker

Channel 6 receive
data

RXD4

receiving
off
flicker

Channel 7 receive
data

L/D4

idle
channel 6 is

data
idle
Channel 7 is
receiving

off
flicker

Channel 8 receive
data

data
Idle
Channel 8 is
receiving
data
idle

off
3. Plug 10BASE-T Ethernet interface card into the DATA
RU
N
RX

Program run indicator


light
channel 1 receive data

flicker

normal program run

Off

abnormal program run

flicker

channel 1 is receiving data

Off

D1
L/D

channel 1 Ethernet port

connection

On

normal
Off

RX

channel 2 receive data

flicker
Off

D2
L/D

channel 2 Ethernet port

connection

On

channel 3 receive data

flicker
Off

D3
L/D

channel 3 Ethernet port

connection

On

connection

Ethernet port
channel 2 is receiving data
Idle
connection

of

Ethernet port of channel 2


Disconnection of channel 2
Ethernet port
channel 3 is receiving data
Idle
Normal

connection

Ethernet port of channel 3

37 , 59

of

Ethernet port of channel 1


Disconnection of channel 1

normal
Off

RX

idle

of

BX10 Integrated Service Platform

Off
RX

channel 4 receive data

flicker
Off

D4
L/D

channel 4 Ethernet port

connection

On

Disconnection of channel 4
Ethernet port
channel 4 is receiving data
Idle
Normal

Off

connection

of

Ethernet port of channel 4


Disconnection of channel 4
Ethernet port

RS232/485 Data Interface Card

Functional Description:
1. Each card provides 2 channels of low-speed RS232 asynchronous interface
(19.2Kb/s) or two channels of RS485 data interface.
2. Each way utilizes one time slot, which may be set by the network management
software freely
3. Each channel provides the transmit and receive circuits
4. The number of RS232/485 data interface cards may be configured as required, 20
at most for 2U machine case and 52 at most for 4U machine case.
Switch setting of RS232/485 data interface cards:
1

RS232/485 interface mode setting:

Position: S3, S4, S5, S6, S7, S8


Function: It is RS232 mode by placing short circuitor at the side with
RS232 printed or RS485 mode by placing short circuitor at the side with
RS485 printed.
Note: S3, S5, S7 are switches for the setting of channel 1. S4, S6, S8 are
switches for the setting of channel 2.

RS485 matched resistance setting::

38 , 59

BX10 Integrated Service Platform

Position: S9, S10, S11, S12


Function: It is the mode with matched resistance by placing short
circuitor at the side with Y printed or the mode without matched
resistance by placing short circuitor at the side with N printed.
Note: S9 and S10 are switches for the setting of channel 1. S11 and
S12 are switches for the setting of channel 2.

RS48
5

self-

adaptation enabling setting:


Position: S1, S2
Function: place the short circuitor at different positions to enable the selfadaptation in RS485 mode or disable it. When it is enabled, it will judge
whether there is RS485 data or not, and open the data channel if there is.
Way of setting: enable it by placing the short circuitor at the side with Y
printed, or disable it by placing the short circuitor at the side with N printed.
Note: S1 is the channel 1 setting switch and S2 is the channel 2 setting switch.

V.35 synchronous data interface card

1. Each card provides one channel of N64Kb/s V.35 synchronous interface


2. Each channel may utilize N time slots ( 1N31), and the time slots may be set
freely through the network management software.
3. Each channel provides the transmit and receive circuits
4. The number of V.35 synchronous data interface cards could be configured as
required, 20 at most for 2U machine case and 52 at most for 4U machine case.
10BASE-T Ethernet interface card
1.

Each card provides one 10BASE - T Ethernet interface

39 , 59

BX10 Integrated Service Platform

2.

Each channel may utilize N time slots ( 1N31), and the


time slots may be set freely through the network
management software.

3.

Each channel provides the transmit and receive circuits

4.

The number of 10BASE-T Ethernet interface cards could be


configured as required, 20 at most for 2U machine case and
52 at most for 4U machine case.

Switch setting of 10BASE-T Ethernet interface card: :

Position: S top tumble switch.


Function: S refers to the Ethernet work mode, and there are 8 switches in all,
of which switch 7 and switch 8 are idle.
Note:
1

Switch 1: for DHCP filter setting (OFF: enable; ON:

disable).
2

Switch 2: for NetBIOS filter setting (OFF: enable;

ON: disable).
3

Switch 3

for repeater mode setting (OFF: enter

repeater mode; ON: not).


4

Switch 4

for velocity setting (OFF: 100MHz;

ON: 10MHz)
5

Switch 5

for transmission mode setting (OFF:

full duplex mode; ON: half-duplex mode)

40 , 59

BX10 Integrated Service Platform

Switch 6

for the self-adaptation setting (OFF:

self-adaptation; ON: no self-adaptation). (when it is set as selfadaptation, switch 4 and switch 5 should be turned to OFF))

41 , 59

BX10 Integrated Service Platform

42 , 59

BX10 Integrated Service Platform

Chapter Three Outgoing Lines


3.1 2M Outgoing Lines of MCUS
MCUS DB37-RJ45 cable
ID: DB37-4RJ45
No.: BX100821
Plug type: One DB37 pin-type plug and four RJ45 plugs.
Cable form: Two connector electric cable, four with one.
Cable wire: 120 Ohm twisted-pair (each is 20CM long)
Outgoing lines:
Plug
type

DB37
Pintype
plug

Pin
No.

Line
color

RJ45 1 port

RJ45 2 ports

RJ45 3 ports

RJ45 4 ports

Outlet
definition

RJ45
Pin No.

Outlet
definition

RJ45
Pin No.

Outlet
definition

RJ45
Pin No.

Outlet
definition

RJ45
Pin No.

LINE+0I

23

LINE-0I

24

LINE+0O

LINE-0O

LINE+1I

27

LINE-1I

28

LINE+1O

10

LINE-1O

12

LINE+2I

31

LINE-2I

32

LINE+2O

14

LINE-2O

16

LINE+3I

35

LINE-3I

36

LINE+3O

18

LINE-3O

43 , 40

BX10 Integrated Service Platform

MCUS DB37-BNC Cable


ID: DB37-8BNC
No.:
Cable form: one DB37-pin bonding wire plug and eight BNC connectors.
Cable form: two-connector cable, one with eight.
Cable line: 75 ohm coaxial line (standard)
Table of outgoing lines:

input
output

core
cloth
core
cloth

10MCUS DB37 table of outgoing lines


channel 1
channel 2
channel 3
4
8
12
23
27
31
24
28
32
6
10
14

channel 4
16
35
36
18

3.2 2M outgoing lines of E1PS

EIPS DB62-BNC Cable


ID:
No.:
Cable form: one DB62-pin bonding wire plug and 16 BNC connectors.
Cable form: two-connector cable, one with sixteen.
Cable line: 75 ohm coaxial line (standard)
Table of outgoing lines:

EIPS DB62-BNC Cable


input

core
cloth

channel 1
43
44

channel 2
1
2

44 , 40

channel 3
24
25

channel 4
47
48

BX10 Integrated Service Platform

output

core
cloth

24
23

45
46

3
4

26
27

channel 1
5
6
49
50

channel 2
28
29
7
8

channel 3
51
52
30
31

channel 4
9
10
53
54

EIPS DB62-BNC Cable


input

core
cloth
core
cloth

output

EIPS DB62-RJ45 Cable


ID: DB62-8RJ45
No.:BX100823
Cable form: one DB62-pin bonding wire plug and eight RJ45 sockets.
Cable form: two-connector cable, one with eight.
Cable line: 120 ohm coaxial line
plug

pin

form

no.

DB62
pin-type
plug

43
44
22
23
1
2
45
46
24
25
3
4
47
48
26
27

plug

pin

form

no.

RJ45 socket(1port)
definition
RJ45

RJ45 socket2port
definition
RJ45

RJ45 socket3port
definition
RJ45

RJ45 socket4port
definition
RJ45

of

socket

of

socket

of

socket

of

socket

outgoing

pin no.

outgoing

pin no.

outgoing

pin no.

outgoing

pin no.

lines
LINE+0I
LINE-0I
LINE+0O
LINE-0O

lines

lines

lines

2
1
5
4
LINE+1I
LINE-1I
LINE+1O
LINE-1O

2
1
5
4
LINE+2I
LINE-2I
LINE+2O
LINE-2O

2
1
5
4
LINE+3I
LINE-3I
LINE+3O
LINE-3O

2
1
5
4

RJ45 socket(5port)
definition
RJ45

RJ45 socket6port
definition
RJ45

RJ45 socket7port
definition
RJ45

RJ45 socket8port
definition
RJ45

of

of

of

of

socket

socket
45 , 59

socket

socket

BX10 Integrated Service Platform


outgoing
DB62
pin-type
plug

5
6
49
50
28
29
7
8
51
52
30
31
9
10
53
54

lines
LINE+4I
LINE-4I
LINE+4O
LINE-4O

pin no.

outgoing

pin no.

outgoing

lines

pin no.

lines

outgoing

pin no.

lines

2
1
5
4
LINE+5I
LINE-5I
LINE+5O
LINE-6O

2
1
5
4
LINE+6I
LINE-6I
LINE+6O
LINE-6O

2
1
5
4
LINE+7I
LINE-7I
LINE+7O
LINE-7O

Definitions of signals of the DB62 hole-type plug


Pin No.

2M signal name

Pin No.

2M signal name

43

R1+

44

R1-

22

T1+

23

T1-

R2+

R2-

45

T2+

46

T2-

24

R3+

25

R3-

T3+

T3-

47

R4+

48

R4-

26

T4+

27

T4-

R5+

R5-

49

T5+

50

T5-

28

R6+

29

R6-

T6+

T6-

51

R7+

52

R7-

30

T7+

31

T7-

R8+

10

R8-

46 , 59

2
1
5
4

BX10 Integrated Service Platform

53

T8+

54

T8-

3.3 VF Cable
ID: BX10-C-2/4W
No.: BX100803
Plug typeOne DB26 pin-type plug
Cable form: one connector electric cable
Cable wire: 16-core audio paired cable 82 0.4 (standard 5M)
Outgoing lines:

Plug type
DB26

Pin
No.
14

pin-type
plug

15

2/4W VF outgoing cable


Line color
Blue
blue
background
and black
ring
Red

Outlet
definition
1-2W/4WT

Automatic

Carrier

Magnet

telephone cable
Outlet

cable
Outlet

cable
Outlet

definition

definition definition

1-2W/4WT

1-4WR

1A

47 , 59

1A

BX10 Integrated Service Platform

red
6

17

18

22

21

20

19

11

12

background
and black
ring
Green
green
background
and black
ring
Brown
brown
background
and black
ring
Grey
grey
background
and black
ring
Yellow
yellow
background
and black
ring
White
white
background
and black
ring
Pink
Pink
background
and black

1-4WR

1B

1B

2-2W/4WT

2-2W/4WT

2-4WR

2A

1A

2-4WR

2B

1B

3-2W/4WT

3-2W/4WT

3-4WR

3A

2A

3-4WR

3B

2B

4-2W/4WT

4-2W/4WT

4-4WR

4A

2A

4-4WR

4B

2B

ring

48 , 59

BX10 Integrated Service Platform

3.4 E/M VF Cable


ID: BX10-C-E/M
No.: BX100829
Plug typeOne DB26 pin-type plug
Cable form: One connector electric cable.
Cable wire: 32-core audio paired cable 162 0.4 (standard 5M)
Note: apply to versions after BX10-EMC V1.2
Outgoing cables:

Plug Pin

Line color

type No.
DB26 14 black background and blue ring
pin-type 5 blue background and black ring
plug

Outgoing lines of EMC


Outlet definition
1-E1
1-M1

15 brown background and red ring

1-E2

red background and brown ring

1-M2

17 black background and green ring

1-2W

8 green background and black ring

1-2W

18 white background and brown ring

1-4W

9 brown background and white ring

1-4W

22 white background and grey ring

2-E1

21 grey background and white ring

2-M1

20 blue background and yellow ring

2-E2

19 yellow background and blue ring


orange background and white
11
ring
white background and orange
2
ring
12 white background and green ring

2-M2
2-2W
2-2W
2-4W

3 green background and white ring

2-4W

16 black background and brown ring

1-SG

7 brown background and black ring


10 blue background and white ring

1-SB

49 , 59

2-SG

BX10 Integrated Service Platform

white background and blue ring

2-SB

ID: BX10-C-E/M
No.: BX10808
Plug typeOne DB26 pin-type plug
Cable form: one connector electric cable.
Cable wire: 32-core audio paired cable 162 0.4 (standard 5M)
Note: apply to BX10-EMC V1.1
Outgoing lines:

Plug Pin
type No.

Line color

Outgoing lines of EMC


Outlet definition

25 black background and blue ring

1-E1

26 blue background and black ring

1-M1

14 brown background and red ring

1-E2

red background and brown ring

1-M2

16 black background and green ring

1-2W

7 green background and black ring

1-2W

17 white background and brown ring

1-4W

8 brown background and white ring

1-4W

4 white background and grey ring

2-E1

DB26 13 grey background and white ring


pin-type 22 blue background and yellow ring

2-M1

21 yellow background and blue ring


orange background and white
10
ring
white background and orange
1
ring
11 white background and green ring

2-M2

plug

2-E2

2-2W
2-2W
2-4W

2 green background and white ring

2-4W

15 black background and brown ring

1-SG

6 brown background and black ring

1-SB

20 blue background and white ring

2-SG

19 white background and blue ring

2-SB

50 , 59

BX10 Integrated Service Platform

3.5 10BASE-T Cable


ID: BX10-10BASE-T
No.: BX100805
Plug typeOne DB26 pin-type plug and two RJ45 sockets
Cable form: two connector electric cable, 1 with 2.
Cable wire: 4-core shielded twisted pair (super CAT 5)
Outgoing lines:
Outgoing 10BASE data cable (1 Outgoing 10BASE data cable (2
Plug type

Pin
No.

port)
Outlet
definition

ports)

RJ45 Pin No.

Outlet
definition

DB26
pin-type

RJ45 Pin No.


white background

TD-2

and blue ring2


[Cable 2]
white background

RX-2

and orange

3
4
5

white background

ring6[Cable 2]

TD-1

and blue ring2

[Cable 1]
white background
RX-1

and orange

8
9
10

ring6[Cable 1]

TX+2

11

RX+2

Blue 1[Cable 2]
Orange 3[Cable

12

51 , 59

2]

BX10 Integrated Service Platform

13
14
15

TX+1

16

RX+1

17
18
19
20
21
22
23
24
25
26

Blue 1[Cable 1]
Orange 3[Cable
1]

3.6 RS232/485 Data Cable


ID: BX10-D-RS232/485cable length
No.: BX100806
Plug typeOne DB26 pin-type plug and four DB9 hole-type plugs.
Cable form: two connector electric cable, 1 with four.
Cable wire: 4-core VF cable
Outgoing lines:
Pin No.
No.

of the
DB26

plug
8

17

14

15

RS232

RS485

Outlet

Outlet

Cable 1

Cable 2

definition definition
RX1
TX1
RX2

RX1+

White

RX1-

Red

TX1+

Green

TX1-

Brown

RX2+

White

RX2-

Red

52 , 59

Cable 3

Cable 4

BX10 Integrated Service Platform

16

TX2

10

12

11

20

12

19

13

10

14

15

11

16

17

25

GND

GND

18

26

GND

GND

RX3
TX3
RX4
TX4

TX2+

Green

TX2-

Brown

RX3+

White

RX3-

Red

TX3+

Green

TX3-

Brown

RX4+

White

RX4-

Red

TX4+

Green

TX4-

Brown
Black

Black
Black

Black

3.7 V35 Data Cable


ID: BX10-D-V35cable length
No.: BX100804
Plug type: One DB26 pin-type plug and four M34 hole-type plugs.
Cable form: two-connector electric cable, 1 with two.
Cable wire: 16-core audio paired cable 82 0.4
Outgoing lines:
Plug

Pin

type

No.

Outgoing V.35 data cable (1 port) Outgoing V.35 data cable (2 ports)
M34 hole-type
M34 hole-type
Outlet
Outlet
definition

plugPin No.

definition

plugPin No.
brown background and

RC-2

black ring X[Cable

RD+2
TD+2
TXC-2

2]
Green R[Cable 2]
Blue P[Cable 2]
grey background and

DB26
pin-type 1
plug
2
3
4

black ring W[Cable


2]
53 , 59

BX10 Integrated Service Platform

red background and


5

TC-1

black ring AA
[Cable 1]
brown background and

RC-1

black ring X [Cable

7
8

RD+1
TD+1

1]
Green R[Cable 1]
Blue P[Cable 1]
grey background and

XTC-1 black ring W[Cable


1]

10

RC+2

Brown V[Cable 2]
green background and

11

RD-2

black ring T[Cable


2]
blue background and

12
13
14
15

TC+1
RC+1

Red Y[Cable 1]
Brown V[Cable 1]
green background and

16

RD-1

black ring T[Cable

TD-2

black ring S[Cable

XTC+2

2]
Grey U[Cable 2]

1]
blue background and
17
18

TD-1

black ring S[Cable

XTC+1

1]
Grey U[Cable 1]

19

TC-2

20

TC+2

21

PGND

red background and black


ring AA[Cable 2]
Red Y[Cable 2]
yellow background and
black ring (A) [Cable 1]

22
23
24

PGND

25
26

GND

yellow background and


black ring (A) [Cable 1]
Yellow B[Cable 1]
GND
54 , 59

Yellow B[Cable 2]

BX10 Integrated Service Platform

Notice: in M34 plug, C (RTS) and D (CTS) are in short-circuit,


and E (DSR), F (DCD) and H (DTR) are in short-circuit.
3.8 V35 and 10BASET Data Cable
ID: BX10-D-V3510BASETcable length
No.: BX100807
Plug type: One DB26 pin-type plug, one M34 hole-type plug and one RJ45 socket.
Cable form: two-connector electric cable, 1 with two.
Cable wire: 16-core audio paired cable [V35] 8X2X0.4 and 4-core shielded twisted
pair (super CAT) [10BASET]
Outgoing lines:
Plug
type

Pin
No.

Outgoing V.35 data cable (1 port)

Outgoing 10BASE data cable (2


ports)

Outlet

M34 hole-type

Outlet

definition

plugPin No.

definition

DB26

RJ45 Pin No.


white background and

pin-type 1

TD-2

plug

blue ring2[Cable
2]
white background and

RX-2

orange ring6
[Cable 2]

3
4
red background and black

TC-1

RC-1

black ring X[Cable

7
8

RD+1
TD+1

1]
Green R[Cable 1]
Blue P[Cable 1]
grey background and

XTC-1

black ring W[Cable

ring AA[Cable 1]
brown background and

1]
10
11
12
13
14

TX+2
RX+2

TC+1

Red Y[Cable 1]
55 , 59

Blue 1[Cable 2]
Orange 3[Cable 2]

BX10 Integrated Service Platform

15

RC+1

Brown V[Cable 1]
green background and

16

RD-1

black ring T[Cable


1]
blue background and

17

TD-1

black ring S[Cable

18
19
20
21
22
23

XTC+1

1]
Grey U[Cable 1]

24

PGND

25
26

GND

yellow background and


black ring (A) [Cable 1]
Yellow B[Cable 1]

Notice: in M34 plug, C (RTS) and D (CTS) are in short-circuit, and


E (DSR) and F (DCD) and H (DTR) are in short-circuit.
3.9 RS232/485 Monitoring Cable
RS232 monitoring cable
RJ45 plug Pin No.

Signal definition

DB9 hole-type
plug

Line color

1
2
TX
3
RX
4
5
GND
6
7
8
RS485 monitoring cable
RJ45 plug pin
number
1
2
3
4

Signal definition

2
3

Blue
Orange

Green

DB9 pin-type

TX+

plug

2
56 , 59

Line color

Blue

BX10 Integrated Service Platform

GND

TX-

RX-

RX+

white background
and blue ring
white background
and orange ring
Orange

3.10 -48 Power Cable


DB3 pin-type
plug
A1
A2
A3

Signal Definition
Negative
Protective ground
Positive

Backboard
Indication
P.G.
+

57 , 59

Line color
Red
Yellow
Black