Академический Документы
Профессиональный Документы
Культура Документы
63 x VC-12
4 x 10/100/1000 BaseT
SYN4E
2 x STM-4 / STM-1
2 x STM-1
4 x 2 Mbit/s
2 x STM-1/4
2 x STM-1
SYNUF
1 x STM-1
63 x VC-12
STM-1
Type tests
Electromagnetic compatibility
FOXMAN-UN network management system
8 x 2 Mbit/s
COBUX
3 x interfaces
SYNAC
8 x 2 Mbit/s
8 x VC-12
System control
DXC UBUSPBUS
alarm 4 x in
alarm 2 x out
synch 2 x in
2048 kHz
Synchronization
Diagnostics
System SW
Management interfaces:
F: RS232
Q1: RS485
Qx: 10 BaseT (RJ45)
RS485 (4-wire)
63 x VC-12
100 Base-FX/LX
1000 Base-SX/LX/TX
6x
100 Base-FX/LX
1000 Base-SX/LX
4 x 10/100 BaseT
NEBRE
Ethernet:
L2-switching
100 Base-FX/LX
1000 Base-SX/LX/TX
16 x VC-12
1 x VC-3
POSUM
Power supply
-48 VDC; 85 W
16 x E1 (2 Mbit/s)
G.703
SYTEL
1 x E3 (34 / 45 Mbit/s)
electrical
IEC TS 61 00065
Emission
EN 55022
Immunity
(ESW)
SYNAD
16 x E1 (2 Mbit/s)
electrical
EMC
NEBRA
Ethernet:
L2-switching
63 x VC-12
synch 3 x out
2048 kHz
- 48 VDC
4 x 10/100 BaseT
NEBRO
Ethernet:
L2-switching
ESD
1 x E3 / T3 (34 / 45 Mbit/s)
Ambient conditions
POSUA
For FOX512: 140 W
24 x ext. alarms
4 x control output
Telephony exchange
8 x 64 kbit/s
G.703
8 x 144 kbit/s
2-wire a/b
TEBIT
Teleprotection &
event recorder
n x 64 kbit/s
ALCAR
Collecting external
alarms
n x 64 kbit/s
GECOD
G.703 module
n x 64 kbit/s
EXLAN
2-wire subscriber
(FXO)
ISDN Modules
ISDN-U interface
2B1Q or 4B3T
n x 64 kbit/s
Protection relay
4 x 2 Mbit/s
OPTIF
Diff protection IF
(max. 4 x ports)
8 x 2 Mbit/s
LOMIF
8 x E1 (2 Mbit/s)
4 x 2 Mbit/s
LOMI4
4 x E1 (2 Mbit/s)
16 x 2 Mbit/s
ETER1
R1: L2-switching
R2: L3-routing
1 x 10/100 BaseT
1 x 100 Base-FX
- 40C + 70C
Humidity
4 x IEEE C37.94
or ABB optics
8 x E1 (2 Mbit/s)
G.703 / G.704
- 40C + 70C
Humidity
Temperature range
- 20C + 55C
without fan
- 20C + 45C
Startup temperature
- 20C
Humidity
SFP overview
4 x E1 (2 Mbit/s)
G.703 / G.704
SYNUF
4 x 10/100 BaseT
n x 64 kbit/s
SWITE
Power over Eth
L2-switching
Temperature range
Operation
REL316
REL551, REL561
RED670, RED650
other relais with IEEE C37.94 interface
Temperature range
Transport (not for batteries BATMO)
power supply
115 VAC
230 VAC
U-BUS (8 x 2 Mbit/s)
6 x 10/100 BaseT
2 x 1000 Base-SX/LX
SYN4E
STM-1 electrical
S-1.1
L-1.1
L-1.2
X-1.2
CWDM
S-4.1
L-4.1
L-4.2
X-4.2
100 BASE-SX x
1 x 10/100 BaseT
4 x V.11 / X.24
1 x 10/100 BaseT
DATAR / DATA4
Legacy data + Eth
(max. 4 x ports)
DATAT / DATA1
Legacy data + Eth
(max. 4 x ports)
4 x 2 Mbit/s
4 x 2 Mbit/s
8 x 2 Mbit/s
4 x V.35
1 x 10/100 BaseT
Programmable IF:
V.24 / V.28
X.24 / V.11
V.35
RS485 (4-wire)
4 x interfaces
1 x 10/100 BaseT
8 x voice
2/4-wire E&M
DATAV / DATA3
Legacy data + Eth
(max. 4 x ports)
DATAS / DATA5
Legacy data + Eth
(max. 4 x ports)
NEMSG
8 x trunk lines
2/4-wire E&M
10 x voice
2-wire a/b
SUBH1
10 x subscribers
(FXS)
30 x voice
2-wire a/b
SUBH3
30 x subscribers
(FXS)
www.abb.com/communicationnetworks
STIC1
SHDSL module
4 x 2 Mbit/s
8 x 1-pair
4 x 2-pair
SHDSL
1 x 1-pair
1 x 2-pair
SHDSL
DTM-M
Desktop 1 x IF
1x
Available interfaces:
n x 64 kbit/s (n = 1-32)
G.703 / G.704, V.24 /
X.21/ V.11 / V.35 / V.36
10/100 BaseT
100 BASE-FX
100 BASE-LX
1000 BASE-SX
1000 BASE-LX
1000 BASE-TX
4 x 2 Mbit/s
1 x 2 Mbit/s
8 x 2 Mbit/s
STIC2
SHDSL module with
power for REG/
DTM-M
Max. 2 x REG
8 x 1-pair
4 x 2-pair
SHDSL
1 x 1-pair
1 x 2-pair
SHDSL
8 x 1-pair
4 x 2-pair
REG
STICx
SHDSL module
1 x 1-pair
1 x 2-pair
SHDSL
Alarm list
Event list
Configuration management
Backup of configurations
Security management
Performance management as per ITU-T G.826
1 x 2 Mbit/s
1 x 2 Mbit/s
SDH / PDH
modules
Protection
modules
Ethernet
modules
Data / voice
modules
Core
modules
DSL
modules
4 x V.24 / V.28
Communication technology
Equipment protection
hot standby
POSUM, COBUX
1+1 HW Protection
Traffic protection
1+1 path protection n x 64 kbit/s TEBIT, OPTIF, NEMSG, DATAx, GECOD, SULIS
SYN4E, SYNVA
SYN4E, SYNUF
PDH: 8 Mbit/s
Power supply
48 VDC, 60 VDC
Architecture
Bus structure
PDH
SDH
SYNAD E1 G.703
PDH / SDH
Optical parameters
Ethernet
EMC
K.20
Safety
Bit rate
Line impedance
Coding
Traffic protection
LTP
Nominal impedance
Channel bandwidth
Bit rate
34/45 Mbit/s
Line impedance
75 asymmetrical
Traffic protection
LTP
483 x 87 x 240 mm
SULIS
Bit rate
Line impedance
Number of ports
Transmission code
Traffic protection
Features
no options
all options
V.11 / X.24
DATA1
DATAT
V.35
DATA3
DATAV
V.24/28
DATA4
DATAR
DATA5
DATAS
Options
Point-multipoint, multipoint-multipoint
Performance monitoring, G.826
Traffic protection
Bit rate
96 V
Number of ports
Transmission code
Not supported
S-1.1
L-1.1
L-1.2
CWDM
X-1.2
CWDM
U-1.2
Number of ports
8 x U-interface to UBUS
Wavelength
nm
1310
1310
1550
1550
1550
Line code
4B3T
dBm
-15
-5
-5
Supported
Supported
Guaranteed sensitivity Rx
dBm
-28
-34
-34
-35
-45
dB
13
29
29
35
50
dBm
-8
-8
-10
-3
-10
S-4.1
L-4.1
L-4.2
CWDM
L-4.2
CWDM
V-4.2
1550
Wavelength
nm
1310
1310
1550
1550
dBm
-15
-3
-3
Guaranteed sensitivity Rx
dBm
-28
-28
-28
-29
-37
dB
13
25
25
30
38
dBm
-8
-8
-8
-8
-9
Ethernet features
RJ45 electrical
L1-Ethernet over PDH functionality
Number of ports
Bit rate
64 kbit/s codirectional
Traffic protection
Protection features
Wavelength
nm
1310
1310
850
1310
dBm
-22
-15
-11
-11
Guaranteed sensitivity Rx
dBm
-29
-25
-17
-19
Traffic protection
dB
10
dBm
-14
-8
-3
-3
Ethernet features
ECC-interfaces
Synch I/O
Ethernet compatibility
Alarm I/O
8 x SBUS access
NEBRA
6 x SFP-cages for
Features
L1-point-to-point or L2-switching
typ. 75%
Number of slots
Number of ports
24 alarm inputs
4 control outputs
Features
Number of modules
for FOX515
Number of fans
Operation
Installation
Above equipment,
for FOX512
2, temperature controlled
Number of fans
Operation
Installation
Above equipment,
Aggregate modules
NEBRE L2 Ethernet
2 x SFP-cages for
None
Features
L2-switching
Traffic protection
Connector
Protection voltage
Protection functions
Event recorder
Traffic protection
24 VDC onboard
None
L2-switching
Features
Traffic protection
64 x PBUS access
SHDSL modules
STIC1 / STIC2
Line code
Line rate
n = 3 ... 32
Service rate
n = 1 ... 32
Transmission range
Up to 25 km
Transmission mode
Remote powering
Only STIC2
Traffic protection
Features
Point-multipoint
FC/PC connector
Transmission code
Attenuation range
Up to 20 dB (approx. 30 km)
Optical wavelength
1300 nm
Traffic protection
Compatibility
Features
48 VDC, 60 VDC
L2-switching features
L3-routing features
1 x 8 Mbit/s, optical
RIP v2
Bit rate
Line impedance
RJ-45 connector
SDH features
Ethernet features
IEC61850 ready
Traffic protection
SDH features
Traffic protection
Compatibility
Number of ports
Coding
Nominal impedance
Channel bandwidth
Number of ports
Coding
Nominal impedance
600
Channel bandwidth
Signalling
E, M, E, M
Tributary modules
Number of ports
Traffic protection
Features
LTP
32 participants
multipoint-multipoint topologies
Traffic protection
2 x SFP-cages for
Note: All modules use one mechanical slot, except where otherwise stated.
ISBUT
Q1-interface RS485
Not supported
Managed equipment
Supported
SNMP northbound/southbound
NEBRO
8 x U-interface to UBUS
typ. 80%
Options
Line code
Operating system
Number of ports
Number of protection ports
Hardware protection
Ethernet port
Features
Teleprotection modules
Managed equipment
Operating system
Remote supervision
Hardware protection
Management interfaces
Features
ISBUQ
RS-485
Core modules
EXLIC
IEC-60825
Standardization
Number of ports
Abbreviations
CMI
CWDM
DSL
DWDM
DXC
ECC
EoL
End of Life
EoS
GbE
Gigabit Ethernet
GFP
IF
InterFace
IP
Internet Protocol
LCAS
LT
Line Termination
LTP
MCMI
MIB
MLPPP
MM
Multi Mode
MSP
NE
Network Element
NT
Network Termination
OHC
Overhaed Channel
OSPF
PAM
PDH
PoE
PPP
RIP
RSTP
SDH
SHDSL
SETS
SFP
SM
Single Mode
SNCP
STM
STP
VC
Virtual Container
VCAT
Virtual Concatenation
VLAN
Virtual LAN
VRRP
1 x 1-pair or 2-pair
V.36, Ethernet)
Line code
Line rate
n = 3 ... 32
Service rate
n = 1 ... 32
Transmission range
Up to 25 km
Options
Remote powering
Line code
Types
Power options
We reserve all rights in this document and in the information contained therein. This system overview does neither claim completeness nor availability of modules or functions and ABB reserves the right to insert, postpone or remove modules and functions without further notice.
Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB Switzerland Ltd, Power Systems, 2015.
Main characteristics