Вы находитесь на странице: 1из 16

DESIGN OF DRAIN ALONG KONDALAMMA PUNTHA ROAD (SOUTHERN SIDE)

DATA
Length of the drain proposed

300.00

Population to be served

3000

Rate of water supply

135.00

Intensity of rain fall

20.00

Catchment area coefficient

0.60

Manning's constant

0.015

Existing RL of the top of proposed retainging


wall at origin

9.200

Proposed RL of the drain sill at origin

8.600

Proposed RL of the drain sill at disposal

8.300

Fall

1 in 1000

Area of Catchment

A1

295.02

134.74

39750.99

39750.99
3.98

A
or
Discharge Calculations
Quantity of sullage

80 pc. Of the quantity of water


supplied

0.80*3000*135/(24*60*60)

Q1

3.75
or

Quantity of Runof

0.004
2.78 CIA

2.78*0.60*20*3.98

132.60932

Q2

133.00
or

Therefore, total discharge Q

Q1 + Q2

0.133
0.137

or

0.14

Assuming 450mm size drain as


shown (at middle of the alignment)
Wetted perimeter p
Area of c/s

2*0.46 + 0.30
0.38

Hydraulic mean depth m

0.45

a/p

0.46

0.45

0.30
1.22 m
0.171 sqm
0.171 sqm
0.140 m

1/n*(m2/3*i1/2)

Mannings formula for velocity

0.65 m/sec
0.30

0.171
0.135
0.306

0.46

Cross section at disposal end


a1
a2
0.45
0.30

0.30

0.31 Sqm
Discharge capacity of the section

0.31*0.65
0.20 Cum/sec

> 0.14 Cum/sec,

hence, ok

m
nos
lpcd
mm per hour

sqm

sqm
Ha

lps

Cum/sec

lps
lps

Cum/sec
Cum/sec
Cum/sec

0.45

co

0.30
0.45

hence, ok

DESIGN OF DRAIN ALONG DNR COLLEGE MAIN ROAD (WESTERN SIDE)


DATA
Length of the drain

625.00

Population to be served

6000

Rate of water supply

120.00

Intensity of rain fall

20.00

Catchment area coefficient

0.65

Manning's constant

0.015

Existing RL of the road top at origin

8.900

Proposed RL of the drain sill at origin

8.670

Proposed RL of the drain sill at disposal


Fall

7.920
1 in 800

Assumed side slope of the drain

0.50 : 1

Area of Catchment

A1

625.00

65.00

40625.00

A2
40625.00
4.06

A
or
Discharge Calculations
Quantity of sullage

80 pc. Of the quantity of water


supplied
0.80*6000*120/(24*60*60)

Q1

6.67

0.007

or
Quantity of Runof

2.78 CIA
146.73

2.78*0.65*20*4.06

Q2

Therefore, total discharge Q

147.00
or

0.147

or

0.154
0.15

Q1 + Q2

or
Assuming a velocity of 1.00m per second,
cross sectional area of the drain
required

0.0002448
0.210

Assuming 450mm size drain as


shown (at middle of the alignment)

0.50

0.45

0.23

Wetted perimeter p
Area of c/s

2*0.50 + 0.23+0.40
0.34
0.45

Hydraulic mean depth m

0.45
0.20

a/p

1.63 m
0.153 sqm
0.090 sqm
0.243 sqm
0.149 m

1/n*(m2/3*i1/2)

Mannings formula for velocity

0.66 m/sec
Cross section at disposal end
a1
a2
0.45
0.30

0.30

0.153
0.135
0.288

0.45

0.23

0.29 Sqm
Discharge capacity of the section

0.29*0.66
0.19 Cum/sec

> 0.15 Cum/sec,

hence, ok

m
nos
lpcd
mm per hour

sqm

sqm
Ha

lps

Cum/sec

lps
lps

Cum/sec
Cum/sec
Cum/sec
Cum/sec/rmt
Sqm
0.20
0.45

0.30
0.45

hence, ok

DESIGN OF DRAIN ALONG DNR COLLEGE MAIN ROAD (BOTH SIDES OF THE ROAD UPTO
RAJIV GANDHI STATUE)
DATA
Length of the drain

320.00

Population to be served

3000

Rate of water supply

120.00

Intensity of rain fall

20.00

Catchment area coefficient

0.65

Manning's constant

0.015

Existing RL of the road top at origin

9.475

Proposed RL of the drain sill at origin

9.245

Proposed RL of the drain sill at disposal


Fall

8.600
1 in 500

Assumed side slope of the drain

0.50 : 1

Area of Catchment

310.00

132.00

40920.00

40920.00
4.09

A
or
Discharge Calculations
Quantity of sullage

80 pc. Of the quantity of water


supplied
0.80*3000*120/(24*60*60)

Q1

3.33
or

Quantity of Runof

2.78 CIA
147.81

2.78*0.65*20*4.09

Q2

148
or

Therefore, total discharge Q

Q1 + Q2

Assuming a velocity of 1.00m per second,


cross sectional area of the drain
required

0.003

0.148
0.151
0.15

or
or 0.0004688

0.150

Assuming 450mm size drain as


shown

0.50

0.45

a1

(0.45+0.23)*0.50*0.45

2*0.50 + 0.23

Wetted perimeter p
Area of c/s

0.34

Hydraulic mean depth m

0.45
a/p

0.153

0.23

1.23 m
0.153 sqm
0.124 m

1/n*(m2/3*i1/2)

Mannings formula for velocity

0.74 m/sec

Cross section at disposal end


a1
a2
0.45
0.20

Cross section at disposal end


Discharge capacity of the section

0.45

0.153
0.09
0.243

0.20
0.45

0.23

0.243 Sqm
0.243*0.74
0.18 Cum/sec
> 0.15 Cum/sec hence, ok

HE ROAD UPTO

m
nos
lpcd
mm per hour

sqm

sqm
Ha

lps

Cum/sec

lps
lps

Cum/sec
Cum/sec
Cum/sec
cum/sec/rmt
Sqm

0.45

nce, ok

DESIGN OF DRAIN ALONG COSMO CLUB MAIN ROAD


DATA
Length of the drain

520.00

Population to be served

6000

Rate of water supply

120.00

Intensity of rain fall

20.00

Catchment area coefficient

0.65

Manning's constant

0.015

Existing RL of the road top at origin

9.630

Proposed RL of the drain sill at origin

9.400

Proposed RL of the drain sill at disposal


Fall

8.700
1 in 750

Assumed side slope of the drain

0.50 : 1

Area of Catchment

A1

208.00

146.00

A2

172.00

50.00

30368.00
8600.00

38968.00
3.90

A
or
Discharge Calculations
Quantity of sullage

80 pc. Of the quantity of water


supplied
0.80*6000*120/(24*60*60)

Q1

6.67
or

Quantity of Runof

2.78 CIA
140.58

2.78*0.65*20*3.89

Q2

141.00
or

Therefore, total discharge Q

Q1 + Q2

Assuming a velocity of 1.00m per second,


cross sectional area of the drain
required

0.007

0.141
0.148
0.15

or
or 0.0002885

0.150

Assuming
450mm
size drain
as shown

0.45
5
0.

0.45

0.23

a1

(0.45+0.23)*0.50*0.45

2*0.50 + 0.23

Wetted perimeter p
Area of c/s

0.153

0.34

Hydraulic mean depth m

0.45
a/p

1.23 m
0.153 sqm
0.124 m

1/n*(m2/3*i1/2)

Mannings formula for velocity

0.60 m/sec
0.45

a1
a2

0.45

0.25

0.153
0.1125
0.2655

0.25
0.45
0.23

Cross section at disposal end


Discharge capacity of the section

0.27 Sqm
0.27*0.60
0.162 Cum/sec
> 0.15 Cum/sec hence, ok

m
nos
lpcd
mm per hour

sqm
sqm

sqm
Ha

lps

Cum/sec

lps
lps

Cum/sec
Cum/sec
Cum/sec
cum/sec/rmt
Sqm

nce, ok

Вам также может понравиться