Вы находитесь на странице: 1из 72

CATALOGUE 08

The universal solution

MX08C/TGB

MTIX

CONTENTS
MTIX: the universal solution
Can be installed in the home

Can be installed in a protected space

Can be installed in the service sector

10

Functions for the home

12

Functions for the service sector

14

Adapts to all rooms - cover plate colours

16

Quick selection tables


Installation with screws, distance between centres 71 mm

18

Installation with clip fastening, distance between centres 71 mm

19

Installation in ush, wall and plasterboard boxes

20

MTIX cover plate colours

21

Combination with special cover plates

22

Special cover plate colours

23

IP40, IP55 enclosures and IP55 covers - IDROBOX devices

24

INTERLINK installation solutions for the service sector

28

Catalogue
Basic control devices

36

Accessories and key cover with lightable symbols

38

TV jacks and special sockets

39

Sockets

40

RJ and EDP connectors

43

Electronic control and adjustment devices

44

Audible and optical signalling devices

46

Optical signalling and emergency lamps

47

Safety devices

48

Gas detectors

49

Lamps - box and support accessories

50

Technical information

52

CONTENTS
MTIX CATALOGOUE

MTIX:
the universal solution

Home

Installability

Protected

IP55 covers
Flush-mounting
installation in wall
or plasterboard,
horizontally,
vertically and
in the centre

Installation in
wall boxes

IP40 covers

Timer thermostat

TV-SAT jacks

Dimmer

IR
switch

Look

Functions

Protected

Whites

Metallics

Stones

Three colours families which t in perfectly with todays rooms and furnishings

MTIX

Service sector
Protected

Installation in
two-side pedestals

Wall mounting in
INTERLINK switchboard

Installation in columns
and minicolumns

Emergency
lamp

IP55 enclosures

IP40 enclosures

Luminous
signalling

Data transmission
and RJ

Neutral colour range suitable for all needs in the service sector for applications on the wall, in trunking, in columns,
in switchboards and in pedestals.
GENERAL FEATURES
MTIX CATALOGUE

Can be installed
in the home
FLUSH-MOUNTED:
IN RECTANGULAR, ROUND
AND SQUARE BOXES

503E ushmounting box


Frame
Devices

Front cover plate

Round ushmounting box


Frame
Devices

Front cover plate

WALL
AVAILABLE IN
ALL MODULAR
CONCEPTS
500

Square box

503E

504E

506L

PLASTERBOARD

PB502

MTIX

PB503

PB504

PB506

Combined vertical
frames

FLUSH-MOUNTED: VERTICAL
OR HORIZONTAL COMBINATIONS

Devices

Vertical front
cover plate

Combined vertical
frames
Devices

Vertical front
cover plate

Combined horizontal
frames

Devices

Horizontal front
cover plate

GENERAL FEATURES
MTIX CATALOGUE

Can be installed
in the home
FLUSH-MOUNTING:
CENTRALISATION
OF FUNCTIONS

MULTIBOX distribution board

WALL-MOUNTED:
FOR UNSUITABLE ROOMS
Front cover plate

Devices
503 ushmounting box

MTIX

Frame

Can be installed
in a protected space
IDROBOX: IP40 - IP55 BOXES
FOR EVERY NEED

Solutions for the home

Solutions for the service and industrial sectors

GENERAL FEATURES
MTIX CATALOGUE

Can be installed
in the service sector
COLUMNS AND MINICOLUMS

One-side
minicolumn

One-side column

10

MTIX

FLOOR, WALL, CEILING AND DESK:


CONCEALED PEDESTALS, PROTRUDING
PEDESTALS AND INTERLINK SWITCHBOARDS

Two-side
pedestals
INTERLINK switchboard

Concealed
pedestals

TRUNKINGS

GENERAL FEATURES
MTIX CATALOGUE

11

Functions for
the home
COMPLETE RANGE OF PRODUCTS
FOR THE DWELLING

CONTROLS

traditional control devices


electronic devices
sockets suitable for all standards

Switches, two-way switches,


intermediate switches, pushbuttons

Relay

SAFETY DEVICES

Earth leakage, pull-out torch, gas detector

12

MTIX

SOCKETS

TV JACKS

DIMMER

ELECTRONIC FUNCTIONS

Thermostat, timer thermostat, timer

GENERAL FEATURES
MTIX CATALOGUE

13

Functions for
the service
sector

CONTROLS

COMPLETE RANGE OF
DEVICES FOR THE OFFICE
traditional and electronic
control devices
sockets suitable
for all standards
RJ connectors
safety devices and
emergency lamps

SAFETY LAMPS

Emergency lamp, signalling lamp,


step-marker lamp

LUMINOUS SIGNALLING DEVICES

14

MTIX

Switches, two-way switches,


intermediate switches, pushbuttons,
fan-coil adjuster

CONTROLS

Safe sockets, fuse-carrier thermal-magnetic


circuit breakers

RJ CONNECTORS AND CONNECTORS


FOR DATA TRANSMISSION

SOCKETS

GENERAL FEATURES
MTIX CATALOGUE

15

Adapts to
all rooms
Whites

Metallics

Stones
MTIX nishes are divided into
three families which t in perfectly
with todays rooms and furnishings.
This is why MTIX is to everyones
taste:
Whites
Metallics
Stones

16

MTIX

Cover plate
colours
UNIVERSAL IN TASTE, UNIVERSAL IN TIME
white (BN)
ash (CN)
ivory (AV)
cord (CD)

1 WHITES

white
ash
ivory
cord

silver (SL)
iron (IR)
titanium (TA)
gold (GL)

2 METALLICS

silver
iron
titanium
gold

WATER PAINTS
The Metallic cover plate family is
completely painted with water
paints. This guarantees the same
quality as traditional paints, with
full respect for the environment.

stone (SP)
aquamarine (SQ)
sand (SS)
earth (ST)

3 STONES

stone
aquamarine
sand
earth

GENERAL FEATURES
MTIX CATALOGUE

17

Installation with screws, distance between


centres 71 mm
Boxes

Frames

No. of modules

Cover plates

AM4802...

AM4702

2 modules
AM4802V...

AM4802/2...

2 x AM4702

2 + 2 modules

AM4802V/2...

AM4802/3...

3 x AM4702

2 + 2 + 2 modules

AM4802V/3...

AM4802/4...

4 x AM4702

2 + 2 + 2 + 2 modules

AM4802V/4...

18

MTIX

Installation with clip fastening, distance


between centres 71 mm
Boxes

Frames

AM4702G

No. of modules

2 modules

Cover plates

AM4802V...

2 + 2 modules

AM4802V/2...

2 + 2 + 2 modules

AM4802V/3...

2 + 2 + 2 + 2 modules

AM4802V/4...

2 x AM4702G

3 x AM4702G

4 x AM4702G

QUICK SELECTION TABLE


MTIX CATALOGUE

19

Installation in ush, wall


and plasterboard boxes
Frames

Boxes

500
( 60x44 mm)

502E
(70x70x50 mm)

PB500
( 69x69x51 mm)

No. of modules

Cover plates

AM4802...

500S/2A
2 moduli

AM4819...

500S/23A

AM4803/1...
503E
503BP
(106x71x52 mm) (123x80x45 mm)
componibile

PB503
(110x69x51 mm)

3 moduli

503SA

AM4803...

AM4819...

2 moduli

503S/2A

504E
(132x74x52 mm)
4 moduli

504SA

AM4804...

PB504
(132,5x69x51 mm)

506L
(183,5x90x53 mm)

506LSA
PB506
(183x69x51 mm)

506E
(106x117x52 mm)

AM4806L...

6 moduli

PB526
(110x115x51 mm)

506SA

6 moduli

AM4806...

NOTE: complete the cover plate code with the colour abbreviation, as indicated below. Boxes 503E can be side mounted with accessory item 503ED.
The protective sheaths for painting (see Accessories section) can be installed on the supports.

20

MTIX

MTIX cover plate colours


Cover plates in technopolymers
Description

White

Ivory

Ash

Cord

BN

AV

CN

CD

Gold

Silver

Titanium

Iron

GL

SL

TA

IR

Sand

Earth

Stone

Aquamarine

SS

ST

SP

SQ

Whites

Description

Metallics

Description

Stones

QUICK SELECTION TABLE


MTIX CATALOGUE

21

Combination with
special cover plates
Frames

Boxes

500
( 60x44 mm)

502E
(70x70x50 mm)

PB500
( 69x69x51 mm)

503E
503BP
(106x71x52 mm) (123x80x45 mm)
componibile

PB503
(110x69x51 mm)

No. of modules

Cover plates

500/2A/...

500S/2A

2 moduli

500S/23A

503/23A/...

503/0/...

503/1A/...

503/0/...

503/2A/...

503/3A/...

503/23A/...

503/0/...

503SA
3 moduli

503S/2A
2 moduli

504E
(132x74x52 mm)
504SA

504/4A/...
4 moduli

PB504
(132,5x69x51 mm)

506L
(183,5x90x53,5 mm)

506LSA

506L/6A/...

PB506
(183x69x51 mm)

6 moduli

Legend

NOTE: complete the cover plate code with the colour abbreviation, as indicated below.
Boxes 503E can be side mounted with accessory item 503ED.
The protective sheaths for painting (see Accessories section) can be installed on the supports.

22

MTIX

Special cover plate colours


Description

Ivory resin

White resin

Resin to be painted ( )

BN

VN

Colour range

NOTE ( ): to be painted with washable or semi-washable water paints, distempers or synthetic water enamels.

Description

Natural aluminium

Oxidal

Bronze

AL

Maple

Oak

Teak

LAE

LRV

LTK

Shiny brass

Colour range

Description

BR

OT

Cover plates
in precious woods

NOTE
As the cover plates are in natural precious wood, there may be slight differences in shade between one cover plate and the next.
The photographs are thus an indication.
Wooden cover plates are only available for installation on round box and 503E box.

QUICK SELECTION TABLE


MTIX CATALOGUE

23

IP40 horizontal
wall-mounting enclosures
Description

Description

1 place

Description

2 places
25401

4 places

3 places

6 places

4 places
25404

8 places

25403

25402

25404/2

12 places

25408

25406

16 places

25412

25416

IP40 vertical
wall-mounting enclosures
Description

Description

4 places

6 places
25404/2V

12 places
25412V

24

MTIX

Description

8 places
25406V

25408V

IP55 horizontal and vertical


wall-mounting enclosures
Description

Description

1 horizontal
place

Description

2 horizontal
places

25503

25502

25501

4 horizontal
places

3 horizontal
places

12 vertical
places

8 vertical
places
25504

25508V

25512V

IP55 protected
covers
Description

Description

Installation on ushmounting box 502


2 places
grey RAL7035

Installation on ushmounting box 502


2 places
stone grey
25602

Description

25602S

Installation on ushmounting box 503E


3 places
stone grey

Installation on ushmounting box 503E


3 places
grey RAL7035
25603

Installation on ushmounting box 503E


blank
grey RAL7035
25603S

23940

QUICK SELECTION TABLE


MTIX CATALOGUE

25

Infrared switch
(relay contacts 8A 250V a.c.)
Description

Description

angle of coverage
140 - IP44

Description

angle of coverage
180 - IP54

angle of coverage
270 - IP54
25550/180

23972N

25550/270

IDROBOX
PLUS
Description

Description

26003 - wall mounting


two way switch - IP55
26005 - wall mounting
pushbutton - IP55

26003 - 26005

wall mounting
enclosure
- 2 modules Mtix
- guarantee IP55
when cover
is closed

wall mounting
container - with
two way switch and
2 modules Mtix
enclosure - IP55

26

MTIX

Description

26055

26200

name plate
pushbutton
- for boxes 503E,
502E, 502
- Finishes: black,
white and tech
- IP55

wall mounting
container for Mtix
sockets - IP66 (the
IP protection rate is
guarantee when
plugs is in and
cover is closed).

26108L - 26108N - 26108T

26066

Junction
boxes
Description

Description

94x82x58 mm

142x82x58 mm
23984

23983

Accessories
for junction boxes
Description

Description

Description

quick click
conduit clamp
20 mm

fairlead
16 mm
23854

threaded
adapter
pitch PG 16
23866/20

23858

Accessories
for device-holder enclosure
Description

Description

elastic fairlead

25700

25700F/16
conduit clamp
IP55 16 mm
25700F/20
conduit clamp
IP55 20 mm

Description

25701
horizontal separator
25701V
vertical separator
25700F/..

25701..

earth terminal
25702

QUICK SELECTION TABLE


MTIX CATALOGUE

27

INTERLINK installation solutions for the


service sector - columns and trunking
Columns and trunking

Boxes

Supporting Frames

Modules

Cover plate

AM4802...

500S/2A
2 modules

120006

500S/23A
FLAT
COVER

129202

129212

AM4819...

120024

120035

120023

503SA

120048

504SA

120026

506LSA

120024

120035

4 modules

3 modules

120045BA

AM4803...

129222

4 modules

6 modules

AM4804...

AM4806L...

CURVED
COVER

129201

129211

123020AL - 123001BA
123001GR - 123001TH

28

MTIX

129221

4 modules

123045BA

Protruding two side modular pedestals


and concealed pedestals
Protruding two-side modular pedestals

150650
(resin-anthracite)

150652
(resin-grey)

150655
(aluminium-grey)

Supporting Frames

No. of modules

150676 x 2

4 modules x 2

150677 x 2

4 modules x 2

Cover plates

150677 x 2

150660
(aluminium-grey)

150677 x 2

Concealed pedestals

Frames

4 modules x 4

No. of modules

Cover plates

4 modules
150701 - 150704
150702 - 150705
150703 - 150706

150713

Wiring accessories
POP-UP
Boxes

Pop-up pedestal

Frames

Modules

150620M
150627A

150625

150620P

3 modules

150627G
150620L

QUICK SELECTION TABLE


MTIX CATALOGUE

29

Mini trunking BTA


and accessories

Base and cover

Connection between
trunking and boxes

Boxes

Supporting frame

Modules

Cover plate

W11500
(22x10)
2 modules

W11121

2 modules

W11538
W11512

4 modules
W11568

W11520
(32x10)
W11511

500S/2A
2 modules

AM4802...

W11521
(32x10)
503S/2A

AM4819...
2 modules

W11517

503SA

AM4803...
3 modules

W11519

503SA

30

MTIX

1 module

AM4803/1...

Base and cover

Connection between
trunking and boxes

Boxes

Supporting frame

Modules

Cover plate

2 modules

W11538
W11552

4 modules
W11568

W11540
(32x15)
500S/2A

W11551

AM4802...

2 modules

W11561
(32x15)
503S/2A

AM4819...
2 modules

W11557

503SA

AM4803...
3 modules

W11559

1 module

503SA

AM4803/1...

ACCESSORIES
Variable
internal
angle

Variable
external
angle

Flat
angle

Cover
junction

End closing
cap

T-junction

W11502

W11503

W11504

W11573

W11505

W11507

W11522

W11523

W11524

W11575

W11525

W11527

W11540

W11542

W11543

W11544

W11576

W11545

W11547

W11561

W11562

W11563

W11564

W11577

W11565

W11567

W11500
W11520
W11521

Separation
Angle joint Junction
for T-junction for 30x30mm box H =
trunking
32mm

Junction
box H =
50mm

Partition for
boxes with
H = 32mm
and H = 50

W11980

W11123

W11514
W11122

W11690
W11684

W11554

Fix o cable/
trunking
retaining clip

W11691

QUICK SELECTION TABLE


MTIX CATALOGUE

31

Holding trunking BTA


and accessories

Base

Cover

Adapter

Frames

Modules

Cover plate

503S/2A

W48000
(85x50)

AM4819...
2 modules

W48006
(130x50)

W48017
(190x50)

503SA

W48301

W48001

AM4803...
3 modules

1 module

503SA

AM4803/1...

ACCESSORIES
Internal
angle

External
angle

Flat
angle

W48000

W48002

W48003

W48004

W48006

W48007

W48009

W48009

W48017

W48018

W48019

W48020

32

MTIX

Cover
junction
(L=80mm)

W48048

Base
junction

Closing
end cap

Cable retaining Partition


clips for
(grey)
device-holding

T-junction

W48175

W48005

W48097

W48047

W48040

W48176

W48010

W48097

W48047

W48178

W48021

W48097

W48047

Junction box
300x300mm

W48025

Skirting
and accessories
Base and cover

Connection between
trunking and boxes

Boxes

Supporting frame

Modules

Cover plate

2 modules

W11538
W11572

4 modules
W11568

500S/2A

W11740
(80x20)

AM4802...

2 modules

W11749

503S/2A

AM4819...
2 modules

503SA

AM4803...

W11750
3 modules

1 module

503SA

AM4803/1...

ACCESSORIES

W11740

Variable
internal angle

Variable
external angle

Junction
cover/base
retaining clip

End closing
cap

Joint for right


around door
frame for mini
trunking up to
50x20mm

Joint for left


around door
frame for mini
trunking up to
50x20mm

T-junction for mini


trunking BTA up to
32x12mm

Universal
T-junction around
door for mini
trunking

Angle connection
for trunking
30x30mm

W11742

W11743

W11744

W11745

W11755

W11756

W11751

W11759

W11752

QUICK SELECTION TABLE


MTIX CATALOGUE

33

Flush and wall-mounting


distribution board
Wall-mounted distribution board

Frames

No. of modules

Cover plates

16136F/0

150415MG

16136D/2

5 modules

Multibox ush-mounted boxes

Chassis

Frames

No. of modules

Cover plates

16136F/0

16136F/5

16102

34

MTIX

16102LT

16135M

5 modules

CATALOGUE

35
MTIX CATALOGUE

Basic control
devices
WHITE COLOUR DEVICES

AM5001
AM5003

AM5011

AM5011/32

IVORY COLOUR DEVICES

A5001
A5003

A5011

A5011/32

SWITCHES
Item
Description
AM5001
1P 16A 250Va.c.
A5001
AM5001/2 1P 16A 250Va.c. - 2 modules
AM5011
2P 16A 250Va.c.
A5011
AM5011/32 2P 32A 250Va.c.
A5011/32
AM5007
2P 16A 250Va.c. with key the key can be taken out even in the
A5007
off position the keys are different
AM5007C* 2P 16A 250Va.c. with key as above - the key are the same
* Items managed on demand. To order consult the BTicino sales staff
TWO-WAY SWITCHES

AM5001/2
AM5003/2
AM5007 - AM5007C
AM5007D - AM5007DC

A5007
A5007D

Item
Description
AM5003
1P 16A 250Va.c.
A5003
AM5003/2 1P 16A 250Va.c. - 2 modules
AM5007D
1P 16A 250Va.c. with key the key can be taken out even in the
A5007D
off position the keys are different
AM5007DC* 1P 16A - 250V a.c. with key - as above - the key are the same
* Items managed on demand. To order consult the BTicino sales staff
INTERMEDIATE SWITCHES CHANGEOVER SWITCHES PRESETTER - KNOB SELECTOR

AM5012

AM5052

AM5012/2

AM5052/2

Item
AM5012
A5012
AM5012/2
AM5052
A5052N
AM5052/2
AM5124
A5124
AM5086
A5086

A5012

A5052N

Description
intermediate switch 16A 250Va.c.
intermediate switch 16A 250Va.c. - 2 modules
changeover switch 1P 16A 250Va.c.
changeover switch 1P 16A 250Va.c. - 2 modules
jack presetter with 2 contacts in closure - 10A 48V
(for plug Item 2124N)
selector switch - rotary changeover switch 1P 3A 250Va.c. - 1 way
- 4 positions to control air conditioners, fans, etc.

MONOSTABLE RELAYS

AM5124

AM5086

A5124

A5086

Item
AM5332/230
A5332/230
AM5332/24
AM5332/12

Description
monostable relay with NO/NC contact 250V a.c. 10A resistive 4A
inductive coil power supply 230V a.c.
relay as above - power supply 24V a.c.
relay as above - power supply 12V a.c.

ELECTRONIC CYCLIC RELAY

AM5332/230 AM5315
AM5332/24 AM5315/34
AM5332/12

AM5305

36

MTIX

A5332/230 A5315
A5315/34

Item
Description
AM5315
cyclic relay 10AX 230V a.c. 3 wires
A5315
AM5315/34 cyclic relay 10AX 230V a.c. 3-4 wires
A5315/34
AUDIO POTENTIOMETER
Item
AM5305

Description
audio potentiometer 0-5W 47 Ohm

WHITE COLOUR DEVICES

AM5005 AM5055
AM5005/1

AM5005/2

AM5005/2A

AM5037

IVORY COLOUR DEVICES

A5005N A5055
A5005/1N

A5037

AM5055/2
AM5037/2

AM5005/2D

PUSHBUTTONS
Item
AM5005
A5005N
AM5005/1
A5005/1N
AM5005/2
AM5055
A5055
AM5055/2
AM5037
A5037
AM5037/2
AM5005/2A
AM5005/2D
AM5006
A5006
AM5054
A5054
AM5008
A5008
AM5057R
A5057R
AM5057V
A5057V
AM5057A
A5057A

Description
1P (NO) 10A 250Va.c.
1P (NC) 10A 250Va.c.
1P (NO) 10A 250Va.c. - 2 modules
double 1P (NO) + 1P (NO) 10A 250Va.c.
double 1P (NO) + 1P (NO) 10A 250Va.c. - 2 modules
double 1P (NO) + 1P (NO) 10A 250Va.c. interlocked
double 1P (NO) + 1P (NO) 10A 250Va.c. interlocked - 2 modules
pushbutton 1P (NO) 10A 250Va.c. lamp - 2 modules
pushbutton 1P (NO) 10A 250Va.c. bell - 2 modules
1P (NO) 10A 250Va.c. with cord-pull
2P (NO) 10A 250Va.c.
pushbutton 1P (NO) + lightable name plate with lamps 11250L,
11250LV, 11251L, 11252L
1P (NO) 10A 250Va.c. + lamp holder for lamps 11250L, 11251L or
11252L - red diffuser
1P (NO) 10A 250Va.c. + lamp holder for lamps 11250LV, 11251L or
11252L - green diffuser
1P (NO) 10A 250Va.c. + lamp holder for lamps 11250L, 11251L or
11252L - orange diffuser

LIGHTABLE CONTROLS FOR SIGNALLING FUNCTIONS

AM5054

A5054

AM5006

AM5008

AM5057R

Description
switch 1P 16A - 250V a.c. - lightable
two-way switch 1P 16A - 250V a.c. - lightable
pushbutton 1P NO 10A - 250V a.c. - lightable

A5006

AM5001L
AM5003L
AM5005L

AM5057V

Item
AM5001L
AM5003L
AM5005L

AM5057A

A5008

A5057R

A5057V

A5057A

CATALOGUE
MTIX CATALOGUE

37

Accessories and key cover


with lightable symbols
WHITE COLOUR DEVICES

AM5000

AM5009

IVORY COLOUR DEVICES

A5000

BLANKING PLATES AND OUTPUTS


Item
AM5000
A5000
AM5000P/2
AM5009
A5009
AM5009/2

A5009

Description
blanking plates key
blanking plates key with knockout - 2 modules
simple output 9,5 mm - 1 module
simple output 9,5 mm - 2 modules

BLANKING PLATE WIYH LIGHTABLE SYMBOL

AM5000P/2

AM5009/2

AM5921...

AM5921W

Item
Description
AM5921...
complete the blanking plate item code with the symbol reference
A5921...
letter
AM5921/2... as above - 2 modules
AM5921W
key with white tag
A5921W
NOTE: using as a substitute for A/AM5001, A/AM5003, A/AM5005, A/AM5012

A5921...

A5921W

AM5921/2...

38

MTIX

TV jacks
and special sockets
WHITE COLOUR DEVICES

IVORY COLOUR DEVICES

TV JACKS
Item
AM5173D
A5173D

AM5173D

AM5173P AM5173DC
AM5173PT

A5173P
A5173PT

A5173DC

AM5173P
A5173P
AM5173PT
A5173PT
AM5173DC
A5173DC

shunted coax jack male connector 9.5 mm for single-user or


centralised TV VHF/VHF antenna systems, shunted not remote
supplied or via centralised satellite
AM5173SAT* shunted coax jack for single-user TV antenna systems, also remote
A5173SAT* supplied and shunted centralised, systems via single-user satellite
and shunted centralised with feed-through and signal current to
select channels and radio systems male TV connector 9.5 mm
SAT connector and female radio 9.5 mm for installation in
rectangular box Item 503E, Item 504E and Item 506L
AM5175D* shunted coax jack for single-user TV antenna systems, also remote
supplied and shunted centralised, systems via single-user satellite and
shunted centralised with feed-through and signal current to select
channels male TV connector 9.5 mm SAT connector F type
AM5173DF type F TV coax connector impedance 75 - screw coupling
* For the best use of the device, all jacks must be used.

A5173SAT

AM5173SAT

AM5175D

A5173D

Description
shunted coax jack for single-user antenna systems, also remote
supplied and centralised and systems via single-user satellite and
centralised with feed-through and signal current to select channels
shielded connection terminals with unlosable screws - 9.5 mm
male connector 1 module
pass-through coax jack as above, single-user excluded built-in
75 impedance adapter
completed jack coax pass-though - as above, single-user excluded

AM5173DF

FRONT COVERS

AM5164/2

Item
AM5164/2
AM5163/2

AM5163/3

Description
front cover for TV-R jacks
front cover for TV-R-SAT jacks

SPECIAL SOCKETS

AM5020

AM5120

AM5189

A5020N

A5120

Item
AM5020
A5020
AM5120
A5120
AM5189
AM5190

Description
special polarised 2P socket irreversible max 24V d.c.
for plug 2020
mignon 2P socket holes 3 mm centre distance 13 m
for auxiliary circuits and similar 6A 24V SELV terminal connection
DIN 2-pole connector - connection to weld HI-FI point-line
5 pole DIN connector for hi- and similar devices - to weld

TERMINAL RESISTANCE
Item
75RT (N)
AM5190

Description
terminal resistance to close 75 impedance lines in collective
antenna systems with cascade connection to be added to the last
feed-through socket in each riser (terminal socket in feed-through
systems) or at the output of the last distribution block (in shunted
systems)
TV jacks back view

COMMON DEVICES

Line-tap

75RT(N)

Die-cast
body

Terminal

CATALOGUE
MTIX CATALOGUE

39

Sockets
WHITE COLOUR DEVICES

AM5113

AM5180

IVORY COLOUR DEVICES

AM5100

A5113

A5180

A5100

STANDARD ITALIAN SOCKET


Item
Description
AM5113
socket 2P+E 10A 250V a.c. - centre distance 19 mm shielded holes
A5113
4 mm
AM5180
socket 2P+E 10A and 16A 250V a.c. - centre distance 19 mm und
A5180
26 mm shielded holes
A5180R
socket as above, red
A5180A*
socket as above, orange
A5180V*
socket as above, green
AM5100
safety socket 2P+E 10A 250V a.c. irreversible for plug Item 2200NA
A5100
or 2200NN
* To order consult the BTicino sales staff.
DUPLEX AND TRIPLEX SOCKETS

AM5180/2

A5180/2

Item
AM5180/2
A5180/2
AM5180/3
A5180/3

AM5180/3

A5180/3

Description
duplex socket 2 sockets in parallel 2P + E 10A and 16A 250V a.c.
centre distance 19 mm and 26 mm 2P extra
(phase-neutral) available for junctions
triplex socket 3 sockets in parallel 2P + E 10A and 16A 250V a.c.
centre distance 19 mm and 26 mm 2P extra
(phase-neutral) available for junctions

STANDARD EGYPTIAN SOCKET


Item
AM5022ET
A5022ET

Description
socket 2P+10A 250V a.c. - contact tube 4-48 - distance 19 mm

Wiring diagram
AM5022ET

A5022ET

COMMON DEVICES
N

A5180R

A5180V

L1

L1

L1

L1

L2L

L2

L2L

L2

A5180A
Legend
auxiliary terminals for small junctions
patching for feed-through line

40

MTIX

WHITE COLOUR DEVICES

Description
socket 2P+E 10/16A 250Va.c. with schuko lateral earth contactsshielded holes
socket as above, red
socket as above, orange
socket as above, green
socket 2P+E 10/16A 250V a.c. with automatic terminals - German
standard - 2 modules with frame and BN cover plate
AM5440/2P socket as above with cover
AM5440/3 socket 2P+E 10/16A 250V a.c. with lateral and central earth
A5440/3
contacts for SCHUKO plugs with aligned pins type P30
centre distance 19 mm shielded holes
A5440/3R
socket as above, red
AM5440/16 socket 2P+E 10A and 16A 250V a.c. - centre distance 19 mm und
A5440/16
26 mm in dual-centre conguration - protected holes; side earth
contacts for SCHUKO plugs; suitable for: standard Italian plugs 2P
and 2P+E 10A and 16A, SCHUKO plugs 2P+E16A
A5440/16R socket as above, red
A5440X16A* socket as above, orange
A5440X16V* socket as above, green
* Items managed on demand. To order consult the BTicino staff

AM5440/2P

A5440/3

AM5440/3

SQUARE MODULE SOCKET


Item
AM5440/2
A5440/2N
A5440/2NR
A5440X2A*
A5440X2V*
AM5440/2M

A5440/2N

AM5440/2

AM5440/2M

IVORY COLOUR DEVICES

SCHUKO BIPASSO DUPLEX SOCKET


Item
AM5451/2

AM5440/16

Description
socket 2P+E 10A and 16A 250V a.c. - centre distance 19 mm und
26 mm in dual-centre conguration - protected holes; side earth
contacts for SCHUKO plugs; suitable for: standard Italian plugs 2P
and 2P+E 10A and 16A, SCHUKO plugs 2P+E16A
2P extra (phase-neutral) available for junctions
AM5451/2R socket as above, red

A5440/16

SHAVER SOCKET
Item
AM5460
A5460

Description
shaver socket with insulation transformer input voltage 230V a.c.
50/60Hz output voltage 115/230V a.c. 20VA

AM5451/2
AM5451/2R

AM5460

A5460

COLOURED SOCKETS

A5440/2NR

A5440X2A

A5440/3R

A5451/2R

A5440X2V

A5440/16R

A5440X16A

A5440X16V

CATALOGUE
MTIX CATALOGUE

41

Sockets
WHITE COLOUR DEVICES

SOCKETS OTHER STANDARDS


Item
AM5430/2
AM5446/2

AM5430/2

AM5025

AM5446/2

AM5025S
AM5025T
AM5025D
AM5025
AM5025S

AM5025T

AM5115S

AM5025D

AM5115DS
AM5028TS
AM5022

AM5115S

AM5115DS

AM5028TS

AM5022/2
AM5232
AM5232/2

42

AM5022

AM5022/2

AM5232

AM5232/2

MTIX

Description
socket 2P+E 10/16A 250V a.c. - shielded holes France standard - 2 modules
socket 2P 10/16A 250V a.c. - shielded holes France standard - 2 modules
socket 2P 16A 127/250V a.c. - shielded holes Euro-American standard
socket 2P 16A 127/250V a.c. - unshielded holes Euro-American standard
universal socket 2P+E 16A 127/250V a.c. - shielded holes Euro-American standard - 2 modules
universal duplex socket 2P+E 16A 127/250V a.c. - shielded holes
- Euro-American standard - 3 modules
socket 2P 15A 127/250V a.c. - unshielded holes American standard
universal duplex socket 2P+E 16A 127/250V a.c.
- unshielded holes - Euro-American standard - 3 modules
socket 2P+E 15A 127/250V a.c. - unshielded holes
- American standard
socket 2P 10A 250V a.c. - holes 4mm - centre distance 19 mm
- Spanish standard
socket as above - 2 modules
socket 2P+E 10A 250V a.c. - holes 4mm - centre distance 19 mm
- off-line earth hole - Spanish standard
socket as above - 2 modules

RJ and EDP
connectors
WHITE COLOUR DEVICES

IVORY COLOUR DEVICES

RJ11 RJ12 CONNECTORS


Item

AM5958/11N

AM5982

A5958/11N

A5982

A5957/12

AM5958/11N
A5958/11N
AM5982
A5982
A5957/12

Type of
connector
RJ11

No. of
pairs
2

For plug
Item
2841/2

Type of
connection
K10

RJ11

2841/2

A terminal

RJ12

2841/2

K10

AM5959/12

RJ12

2841/2

K10 (2 modules)

RJ45 CONNECTORS
Item
AM5959/12

AM5979/5E
AM5979/6

AM5979/5S
AM5979/6S

AM5962/5S AM5962/6
AM5962/6S AM5962/5E

AM5974AT5
AM5974AT6

A5979/5E
A5979/6

A5974AT5
A5974AT6

A5979/5S
A5979/6S

AM5979/5E
A5979/5E
AM5979/6
A5979/6
AM5979/5S
A5979/5S
AM5979/6S
A5979/6S
AM5962/5E
AM5962/5S
AM5962/6
AM5962/6S
AM5974AT5
A5974AT5
AM5974AT6
A5974AT6
(1) 110 type
(2) SYSTIMAX type
(3) TOOLLESS type

Type of
connector
RJ45

Category

Type

5E

UTP

Type of
connection
cutter (3)

RJ45

UTP

cutter (3)

RJ45

5E

shielded

cutter (3)

RJ45

shielded

cutter (3)

RJ45
RJ45
RJ45
RJ45
RJ45

5E
5E
6
6
5E

UTP
shielded
UTP
shielded
UTP

cutter (1)
cutter (1)
cutter (1)
cutter (1)
cutter (2)

RJ45

UTP

cutter (2)

FIBER OPTIC CONNECTORS

AM5951SC AM5951ST

AM5951LC

Item
Description
AM5951ST* coupling connector for ber optic cable ST termination - duplex
AM5951SC* coupling connector for ber optic cable SC termination duplex
AM5951LC* coupling connector for ber optic cable LC termination duplex
* Items managed on demand. To order consult the BTicino staff

Wiring without tools


(Toolless)

Wiring using the


impact tool (110)

CATALOGUE
MTIX CATALOGUE

43

Electronic control and


adjustment devices
WHITE COLOUR DEVICES

AM5702

AM5706

AM5703
AM5704
AM5707

IVORY COLOUR DEVICES

A5702

A5706

DIMMER
Item
AM5702
A5702
AM5706
A5706
AM5703
A5703
AM5704
AM5707

Touch dimmer - MOS-FET tech. SOFT START and SOFT STOP


anti-dazzling function - built-in fuse
Touch dimmer
Touch dimmer - MOS-FET tech. SOFT START and SOFT STOP
anti-dazzling function - built in fuse
NOTE: to choose the dimmer according to the technical features, see the table
below
PASSIVE INFRARED SWITCHES

A5703

Item
AM5751
A5751

AM5752
A5752
AM5751

AM5752

A5751

Description
Rotary dimmer - built-in two way switch - MOS-FET tech. - built-in
fuse
Rotary dimmer

A5752

Description
switch with passive infrared ray movement sensor variable
threshold twilight circuit with possibility of exclusion timing
circuit to delay switching off which can be adjusted from
30 seconds to 10 minutes out put relay 2A resistive/inductive
230V a.c. power supply 50 and 60Hz
switch with passive infrared ray movement sensor variable
threshold twilight circuit with possibility of exclusion timing
circuit to delay switching off which can be adjusted from 30
seconds to 10 minutes which can also be activated by external
pushbuttons relay output 6A resistive/2A inductive with O-A-I
selector switch for resistive loads up to 200W max 230V a.c.
power supply 2 modules 50 and 60Hz

BADGE-HOLDER POCKETS

AM5765
AM5765/2

A5765

Item
AM5765
A5765

AM5765/2

COMMON DEVICES

L4546
L4405/60 - L4405/105

Description
badge-holder pocket max charge 30VA 230V a.c.
- built-in lamp
- with timer - 3 modules
- in 503E box with 503SA frame to be installed
badge-holder pocket max charge 30VA 230V a.c.
- built-in lamp
- with timer - 3 modules - for box 60mm
- in round box with 500S/23A frame to be installed
key-holder card with badge-holder pocket

COMMON DEVICES

Electronic transformers for halogen lamps


Item
L4405/60
L4405/105

Description
Electronic transformer for low voltage halogen lamps - supply
230Va.c. - 50Hz output 12V - controllable power 20W to 60W
As above controllable power 35W to 105W

L4546

Table to choose the dimmers

Loads Type
Resistive
Resistive
Resistive-ferromagnetic transf.
Ferromagnetic transf. Resistive
For electronic transformer

44

MTIX

Power
60 to 500 W
100 to 500 W
60 to 500 VA
50 to 500 W
50 to 1000 W
60 to 250 VA

Voltage (Va.c.)
230
230
230
127
230
230

Frequency (Hz)
50
50 and 60
50

Item
AM5702
AM5706
AM5703

50 and 60

AM5704

50

AM5707

WHITE COLOUR DEVICES

IVORY COLOUR DEVICES

THERMOSTATS AND TIMER THERMOSTAT


Item
AM5711
A5711
AM5712
A5712
A5721

A5711
A5712

AM5711
AM5712

Description
electronic room thermostat relay output with 1 contact in switch
ing 2A 250V a.c. 230V a.c. power supply 50 and 60Hz
electronic room thermostat with built-in summer/winter
changeover switch relay output with C-NO 2A 250V a.c. contact
230V a.c. power supply 50 and 60Hz
daily/weekly electronic chronothermostat for heating and
conditioning systems - backlighted display - power supply with
battery 2x1,5V - control possibility by a remote teleactivation and
connection with an external temperature probe - output contact in
exchange 1A - 3 modules

POLYX CLIMA
Item
N4450
AM5155

A5155

Description
wall mounting Daily/weekly electronic chronothermostat for
heating and conditioning systems - liquid crystal display - power
supply with battery 2x1,5V - output contact in exchange 1A
cos 0,5 - possibility of connection to a temperature external probe

TIMER
Item
AM5155
A5155

A5766

AM5766

PROGRAMMER
Item
AM5766
A5766

COMMON DEVICES

Description
electronic timer with adjustment 1 to 12 minutes remote control
with pushbuttons 230V a.c. power supply - output contact 10AX
250V a.c.

Description
electronic daily/weekly timer thermostat four daily cycles with
independent or repeatable programming 230V a.c. power supply
output contact 8A resistive/2A inductive 230V a.c.

ACCESSORIES
Item
F462
3457
AM5721

F462

Description
GSM telefonic actuator - 4 DIN modules
external probe for AM5721

N4450**

3457

** Not modular devices for wall mountin installation

CATALOGUE
MTIX CATALOGUE

45

Audible and optical


signalling devices
WHITE COLOUR DEVICES

AM5031
AM5041

AM5045
AM5048
AM5045EL

IVORY COLOUR DEVICES

A5031N
A5041N

A5045N
A5048N

BUZZERS AND BELLS


Item
AM5045
A5045N
AM5048
A5048N
AM5031
A5031N
AM5041
A5041N

Description
buzzer 12V a.c. - 5VA - 74dB
buzzer 230V a.c. - 10VA - 75dB
bronze bell 12V a.c. - 5VA - 80dB
bronze bell 230V a.c. - 11VA - 80dB

ELECTRONIC BELL
Item
AM5755/12
A5755/12
AM5045EL
AM5755/12

46

A5755/12

LAMPHOLDER

AM5062B

AM5064V

A5062B

A5064V

AM5060A

AM5060R

A5060A

A5060R

AM5060B

AM5060V

A5060B

A5060V

MTIX

Description
electronic bell - 3 different rings - with front volume adjustment
- power supply 12V a.c./d.c. - 2 modules
electronic buzzer 12V a.c. - 0,9VA, 12V d.c. - 0,5W, 70 dB

Item
AM5062B
A5062B
AM5064V
A5064V
AM5060A
A5060A
AM5060R
A5060R
AM5060B
A5060B
AM5060V
A5060V

Description
double lampholder with 2 diffussers: 1 orange + 1 clear for lamps Item 11250L - 11251L -11252L
double lampholder with 2 diffussers: 1 red + 1 green - for lamps
Item 11250L (11250LV in the green lamp holder) - 11251L - 11252L
lampholder with orange diffuser
- for lamps Item 11250L - 11251L - 11252L
lampholder with red diffuser
- for lamps Item 11250L - 11251L - 11252L
lampholder with clear diffuser
- for lamps Item 11250L - 11251L - 11252L
lampholder with green diffuser
- for lamps Item 11250L - 11251L - 11252L

Optical signalling devices


and emergency lamps
COMMON DEVICES

A5386/12B
A5386/12R
A5386/12V

PLATES FOR OUTSIDE-DOOR SIGNALLING

A5386/24B
A5386/24R
A5386/24V

Item
Description
A5386/12B power supply 1V - red, green, white colours
A5386/12V LED supplied - 0,6W
A5386/12R
A5386/24B power supply 24Va.c. - red, green, white colours
A5386/24V LED supplied - 0,6W
A5386/24R
A5386/230B power supply 230Va.c. - red, green, white colours
A5386/230V LED supplied - 0,6W
A5386/230R
NOTE: all the models should be installed between 160 and 205 cm above the
ground. When the installation is complete the device protrudes 52mm from the
wall.

A5386/230B
A5386/230R
A5386/230V

STEP MARKER LAMP


A5630/12
A5630/24
A5630/230

A5631/12
A5631/24
A5631/230

A5625/12
A5625/24
A5625/230

Item
A5630/12
A5630/24
A5630/230
A5631/12
A5631/24
A5631/230

Description
step marker lamp with white light LED - 12V a.c. - ON OFF switch
step marker lamp with white light LED - 24V a.c. - ON OFF switch
step marker lamp with white light LED - 230V a.c. - ON OFF switch
step marker lamp with white light LED - 12V a.c.
step marker lamp with white light LED - 24V a.c.
step marker lamp with white light LED - 230V a.c.

SIGNALLING LAMPS
Item
A5625/12
A5779

L4380/B

A5625/24
A5625/230

Description
signalling lamp with high luminous efciency white light LED 12V a.c.
signalling lamp with high luminous efciency white light LED 24V a.c.
signalling lamp with high luminous efciency white light LED
- 230V a.c.

RECHARGEABLE TORCH
Item
A5779
A5774/1
A5774/3

L4380/B

Description
independent pull-out torch with automatic switch ON device
complete with recharge base high luminous efciency white
light LED - interchangeable NiMH batteries no memory effect
autonomy 2 hours low consumption in stand-by 0.4W
230V a.c. power suply 2 modules
spare battery for rechargeable torch

EMERGENCY LAMPS
Item
A5774/1
A5776/1 - A5776/1L
A5776/3 - A5776/3L
A5774/3
A5776/1
A5776/3
A5776/1L
L4784/1
L4784/3

L4786/1
L4786/3

A5776/3L
L4784/1
L4784/3
L4786/1
L4786/3

Description
emergency lamp which automatically switches on when there
is a power failure - voltage ON signalling LED - local disabling
pushbutton - can be excluded remotely by means of a switch
- rechargeable replacement nickel-cadmium battery - autonomy
1 hours - 230V a.c. power supply - lamp power 1W - 4 modules
emergency lamp as above - 3 hours autonomy
emergency lamp as above - 1 hour autonomy lamp power 1.3W 6 modules
emergency lamp as above - 3 hours autonomy
emergency lamp as above - with permanent lighting function for rooms which need light 24h - 1 hour autonomy
emergency lamp as above - 3 hours autonomy
spare battery for lamp Item A5774/1
spare battery for lamp Item A5774/3
spare battery for lamp Item A5776/1 and A5776/1L
spare battery for lamp Item A5776/3 and A5776/3L

CATALOGUE
MTIX CATALOGUE

47

Safety
devices
WHITE COLOUR DEVICES

AM5206S
AM5210S
AM5216S

AM5246S
AM5250S
AM5256S

IVORY COLOUR DEVICES

A5206S
A5210S
A5216S

A5246S
A5250S
A5256S

AUTOMATIC THERMAL-MAGNETIC CIRCUIT BREAKERS 230V A.C.


Item
AM5206S
A5206S
AM5210S
A5210S
AM5216S
A5216S

circuit breaker as above 16A - breaking power 3000A 230V a.c.

AUTOMATIC EARTH-LEAKAGE CIRCUIT BREAKERS 230 VA.C.


Item
AM5246S
A5246S

AM5250S
A5250S
AM5256S
A5256S

AM5114

Description
automatic thermal-magnetic circuit breakers 1P+N 6A 230V a.c.contacts open or closed indicator - breaking power 1500A 230V a.c.
circuit breaker as above 10A - breaking power 3000A 230V a.c.

Description
Salvavita - two-pole automatic thermal-magnetic circuit with
one protected I.n 10mA 6A 230V a.c. contacts open or closed
indicator test pushbutton - breaking power 1500A 230V a.c.
2 modules
Salvavita as above - 10A - breaking power 3000A 230V a.c.
Salvavita as above - 16A - breaking power 3000A 230V a.c.

INTERLOCKED SOCKETS
2P+E socket with shielded pins degree of protection 2.1 interlocked with
automatic thermal-magnetic circuit breaker 1P + N 2 modules
Item
AM5114
AM5130

AM5130

In
10A
16A

Vn
230Va.c.
230Va.c.

Breaking power
3000A 230Va.c.
3000A 230Va.c.

FUSE-CARRIERS AND FUSES

AM5088

AM5471

A5088

A5471

Item
AM5088
A5088

Description
fuse-carrier for 5 x 20 and 6,3 x 32 fuse - max. 10A 250V a.c.

SURGE ARRESTERS
Item
AM5471
A5471

48

MTIX

Description
1P surge arrester to be coupled with the user power supply socket
rated discharge current In=1kA maximum current Imax=2ka
max protection voltage Up=1kV rated voltage Un=110-230V a.c.
max permanent voltage Uc=250V a.c.

Gas
detectors
WHITE COLOUR DEVICES

AM5731/12

IVORY COLOUR DEVICES

A5731/12

GAS DETECTORS
Item
Description
AM5731/12 METHANE gas detector with optical and audible 85dB
A5731/12
alarm signal - internal self-diagnosis - set up for signal
repeater command - power supply 12V a.c./d.c. 2 modules
AM5732/12 detector as above for GPL gas
A5732/12
SIGNAL REPEATER
Item
AM5730
A5730

AM5732/12

A5732/12

TRANSFORMERS
Item
AM5734
A5734
F91/12E

A5730

AM5730

A5734

AM5734

Description
signal repeater for gas detectors - optical/audible
signalling - relay output with 1 contact in switching
6A resistive 2A inductive - 2 modules

Description
safety transformer - input 230V a.c. - 50/60Hz output 12V a.c. - power 4VA - 2 modules
DIN safety transformer - input 230V a.c. - 50/60Hz
- output 12V a.c. - power 6VA - container for DIN rail
3 modules

SOLENOID VALVE
Item
Description
L4525/12NO normally open gas solenoid valve - manual reset power supply 12V 50Hz - absorbed power 3VA absorption at rest zero - max pression 500mbar degree of proteciton IP 65 - operating temperature
15 to +60C - threaded couplings 3/4 and reduction
supplied 1/2

COMMON DEVICES

L4525/12NO

F91/12E

CATALOGUE
MTIX CATALOGUE

49

Lamps - Box and


support accessories
LAMPS

11250L-11250L/127
11250LV-11250LV/127

Item
Description
11250L
location discharge bulb 230V - coupling with studs - clear
11250L/127 location discharge bulb 127V - coupling with studs - clear
11250LV
location discharge bulb 230V - coupling with studs - green
11250LV/127 location discharge bulb 127V - coupling with studs - green
11251L
incandescent signalling bulb 12V
11252L
incandescent signalling bulb 24V
L4741/230* precabled location discharge bulb 230V 1.5mA - clear
L4741/230V* precabled location discharge bulb 230V 1.5mA - green
* not suitable to backlight the pushbuttons which control relays or
electronic devices

11251L
11252L

L4741/230
L4741/230V

BOX AND SUPPORT ACCESSORIES


Item
503CG
503EC
503EV
503ED
503DE
AM5590/3

503CG

Description
protective cover which can be used during wall nishing
work
nishing cover for closing can be dyed
internal resin separator
horizontal and vertical coupler
internal resin divider for boxes item 504E
protection sheath for 3 module support can be used
during nishing plastering works

503EC
503EV

503DE

503ED
AM5590/3

USING FOR BACKLIGHTING


For devices - items
L4741/230** L4741/230V
AM5001, AM5003, AM5005, AM5005/1

AM5001L, AM5003L, AM5005L


AM5011, AM5012
AM5054, AM5057R, AM5057V*, AM5057A
AM5008
AM5060A, AM5060B, AM5060R, AM5060V
AM5062B, AM5064V*
A5385/12..., A5385/24..., A5385/230...
* for pilot lamps with a green diffuser with power supply voltage 230V, use lamp 11250LV
** not suitable for backlighting pushbuttons that control relays or electronic devices
NOTE: list for MTIX white colour devices and relative ivory colour devices (item coda A...)

50

MTIX

11251L 11252L

11250L 11250LV

SECTION INDEX
Technical information
52

Luminous controls

53

Dimmer

55

Electronic control devices

56

Socket outlets

57

TV + SAT jacks

58

Control

61

Audible and luminous signalling devices

62

Emergency devices

63

Electrical safety devices

66

IP40 and IP55 enclosures

68

Electronic devices in protected version

70

Dimensional data

51
MTIX CATALOGUE

Luminous
controls
PREWIRED LAMP AND LUMINOUS CONTROLS L4741/230 E 127 - L4741/230V E 127V
PREWIRED LAMP

LAMP INSTALLATION

This new Item allows to quickly and easily light up switches or pushbuttons with
locating lamps.
In fact, for the mechanical coupling and the electrical connection, it is enough to
t the lamp into the special socket in the back of the control device.
For other functions different from the locating one, or for 12V or 24V input,
the control devices can be lighted with the lamps Item No. 11250L, 11250LV,
11251L, 11252L.

L4741/230 - L4741/127
L4741/230V - L4741/127V
230V a.c. - 1.5mA
127V a.c. - 1.5 mA

LUMINOUS CONTROLS

The following diagrams allow for the implementation of light points that can
be identied with locating lamps or pilot lamps; they adapt to basic control
devices (switches, two-way switches, intermediate switches) of all Bticino
domestic lines.

LOCALIZATION LAMP

For identifying control pushbuttons in the dark.


lamps:

PILOT LAMP

For indicating the operation status of users equipment not visible from the
control point.

lamps:

11250L and /127


11250LV and /127

lamps:

L4741/230 and /127 lamps:


L4741/230V and /127
11250L and /127
11250LV and /127

11250L and /127


11250LV and /127

switch
cut off
lamps:
switch
cut off
lamps:

two-way switches

52

MTIX

two-way switches
diverted

L4741/230 and /127


L4741/230V and /127
11250L and /127 11250L and /127
11250LV and /127 11250LV and /1271

L4741/230 and /127


L4741/230V and /127
11250L and /127
1250LV and /127

diverted
11250L and /127 - 11250LV and /127

inverse

inverse

L4741/230 and /127


L4741/230V and /127
11250L and /127
11250LV and /127

two-way
switch

intermediate
switch

two-way
switch

two-way
intermediate switch
two-way switch
switch
This diagram may be useful in case of controls acting on relays,
electronic devices or energy saving lamps (for example, compact
uorescent lamps).

Dimmer
KNOB DIMMER AM/A5702 - AM/A5706

Knob dimmers allow for resistive load adjustment. They can be supplied with
or without a built-in two-way switch.
Device AM5702 must be protected with a fuse type T2.5H 250V, thereby
making it possible to adjust the load from one point and switching on and
off from different points through two-way switches or external switches.
Instead, device AM5706 makes it possible to adjust the load and to switch it
on and off through the built-in two-way switch; it can therefore be replaced
with a normal switch or two-way switch without modifying the system. It
has been designed with a new technology which does not require the use
of the lter coil, thereby making it absolutely noiseless but, at the same
time, in compliance with the standards on the emission of electromagnetic
disturbances.

Technical features

- power supply: 230V a.c. AM/A5702=50Hz and 60Hz AM/A5706=50Hz


- type of load: resistive (incandescent lamps only)
- power: (see dimmer page on catalogue section)
Wiring diagram device AM5702
Control from 1 point

Control from 2 points

PUSHBUTTON DIMMER AND PUSH-PUSH AM/A5703 - AM5704

These dimmers can control resistive loads and ferromagnetic transformers


(power between 60VA and 500VA) from one or more points.
They are designed with a new technology which ensures compliance with
the standards on the emission of electromagnetic disturbances without the
use of lter coils. This feature allows the devices to be totally noiseless. The
quick pressure of the knob, or one of the pushbuttons connected externally,
activates the load and sets it according to the level of the last adjustment
that was made; a second quick pressure deactivates it. When switching
on, the devices enable the load in order to gradually reach the set level of
brightness to avoid dazzling phenomena (soft-start); switching off also occurs
gradually (soft-stop).

Technical features

- power supply: AM/A5703=230Va.c. 50Hz, AM5704=110-127-230V a.c. 50 and 60 Hz


- type of load: resistive or ferromagnetic transformer
- power: (see dimmer page on catalogue section)
Wiring diagrams
Control and adjustment from 1 point
N

P L

An inbuilt fuse type T2.5H250V selfprotects dimmers against short circuits.


Using dimmers powered by uninterrupted power supplies or by a generator
set may cause malfunction.
Installation notes
For proper operation of all dimmers, follow the instructions below during
installation:
- do not use two or more dimmers together in the same box
- do not install in boxes where there are thermostats

230V

Control and adjustment from 2 or more points


N

P L

max 50

230V

TECHNICAL INFORMATION
MTIX CATALOGUE

53

Dimmer
DIMMER FOR ELECTRONIC TRANSFORMERS AM5707

This dimmer can control electronic transformers for powering up low voltage
quartz-iodine lamps (with power between 60VA e 250VA). It is designed
with a new technology which ensures compliance with the standards on the
emission of electromagnetic disturbances without the use of lter coils. This
feature allows the device to be totally noiseless. The quick pressure of the
local pushbutton, or one of the pushbuttons that can be connected externally,
activates the load and sets it according to the level of the last adjustment
that was made; a second quick pressure deactivates it. An extended pressure
of the pushbutton makes it possible to adjust the min-max / max-min load.
When switching on, the device enables the load to gradually reach the
set level of brightness in order to avoid dazzling phenomena (soft-start);
switching off also occurs gradually (soft-stop).
An inbuilt fuse type T2.6H250V selfprotects dimmers against short circuits.
Using a dimmer powered by uninterrupted power supplies or by a generator
set may cause malfunction.
Installation notes
For proper operation of all dimmers, follow the instructions below during
installation:
- do not use two or more dimmers together in the same box
- do not install in boxes where there are thermostats item AM5711 and item
AM5712.

Technical features

- power supply: 230Va.c. 50Hz


- type of load: for electronic transformers
- power:
60 to 250 VA
Wiring diagram

P L

(1)

Control from 2
or more points

MAX
50m

(1) electronic transformers

MTIX

230V~

P L

(1)

54

Control from
1 point

230V~

Electronic
control devices
PASSIVE IR SWITCH AM/A5751 - AM/A5752

The passive IR switch opens up new prospects in the eld of automatic


mechanisms, allowing to automatically switch on devices as passers-by
approach (for example, light turns on without touching any switch or
pushbutton). It is possible to adjust the device sensitivity threshold according
to the room natural lighting and to adjust the end-of-operation delay after
last movement has been detected, to optimise performance.
The detection range can be widened by installing several devices at different
places, with outputs connected in parallel.
Volumetric coverage is achieved with 3 levels of rays A, B and C with plus-2,
minus-6 and minus-30 degrees orientation relative to the installation axis,
and reaches 4 meters.

Wiring diagram AM/A5751


L
230Va.c.
N

N L L1

Covering elds
105

h = 1,20 m
2,00

+2
A 0

1,20

B -6

C -30

Basic wiring diagram AM/A5752


B

C C

P NO C

P NO C

105

h=2m
A

+2
A 0

2,00
1,20

B -6

-30

B A B A B

C C

Wiring diagram with pushbuttons (IR + timer) AM/A5752

C
m

L N
L N

Technical features - device AM/A5751

- power supply:
230Va.c. 50 and 60Hz
- controllable loads:
2A resistive load, incandescent lamps and ferromagnetic transformer
2A cos0.5 inductive load
- adjustment of time for switching on: from 30 seconds to 10 minutes
- twilight adjustment: from 5 lux to dark
Technical features - device AM/A5752

P NO C

P NO C

L N
L N

- power supply: 230V a.c. 50 and 60Hz


- controllable loads:
2A inductive load and uorescent lamp
6A resistive load, incandescent lamps and ferromagnetic transformer
- adjustment of time for switching on: from 30 seconds to 10 minutes
- twilight adjustment: from 5 lux to dark
- controllable with external pushbuttons
- selector O-A-I (manual operation with external pushbuttons, automatic and external pushbuttons always ON).

TECHNICAL INFORMATION
MTIX CATALOGUE

55

Socket
outlets
SAFETY SOCKETS

The (totally separated) tulip safety sockets can be accessed only with a
special plug that closes the contact when it is completely in.
The contact is guaranteed by the pressure of special spiral springs.
Plugs with a different capacity cannot be interchanged, thus it is possible to
substantially separate several circuits.

More signicant testing conditions

- testing voltage: gradual 2000V 50Hz per minute


- insulation resistance tested at 500V: > 5M .
- breaking test: 100 plug connection/disconnection operations at 275V a.c. cos
0.6 - 12.5A (for 10A plugs), 20A (for 16A plugs).
- extended operational test: 10000 plug connection/disconnection operations at
250V a.c. cos 0.6 with rated current.

Rated features and classication (according to Standards CEI 23-16/VII-1971 and 23-5/I-1972) of plug-in sockets for domestic uses and the like.

Type of
device

No. of
poles

Coupling
mode

Reference
abbreviation

Rated
current

Type of
current

Rated
voltage

Type of
device

Terminal
position

separated

2P+E

irreversible

P13

10A

~ 50Hz

250V~

modular

back

Maximum
conductor
size
4mm2

2P+E

irreversible

P19

16A

~ 50Hz

250V~

modular

back

4mm2

2P+E

reversible

P11

10A

~ 50Hz

250V~

modular

back

2x4mm2

2P+E

reversible

P17

16A

~ 50Hz

250V~

modular

back

2x4mm2

2P+E

reversible

P11/17

10 and 16A

~ 50Hz

250V~

modular

back

2x4mm2

2P+E

reversible

10/16A

~ 50Hz

250V~
and d.c.

nonmodular

back

2x4mm2

tulip plug-in
sockets
separated

tulip plug-in
sockets
shielded
tulip plug-in
sockets
shielded
tulip plug-in
sockets
shielded
tulip 2-center
sockets
plug-in sockets
with earth
side contacts

SHAVER SOCKET AM5460

The transformer is connected to power line only when the plug is inserted
by means of a button (1) to avoid useless loss, heating and humming, and
is protected by a thermal effect device which automatically disconnects the
primary when load exceeds 20VA.
Reconnection is automatic after the protective device has cooled down.
The shaver socket is typically installed in hotels, pensions and similar, for
customers safety and to avoid illegal use of the bathrooms socket.

Wiring diagram

115V
230Va.c.
230V

Technical features

20VA transformer:
- primary 230V a.c. 10% 50Hz
- two 115V or 230V a.c. secondaries that can be selected with a commutator
- max conductor size: 2.5 mm2

56

MTIX

TV + SAT
jacks

TV

TV

Ap

DIRECT JACKS (EXTENSIONS)

AM/A5173SAT

PASS-THROUGH JACKS

TV

TV

Ap

AM/A5173PT

Ad

TV

AM/A5173P

Ad
Ad

TV
TV

TV

TV

TV

AM/A5173DC

AM/A5173D

TV
TV

Ap

Ap

LEGENDA:
Ap = Pass through attenuation
Zo = Characteristic impedance
Ad = Direct attenuation (or bridging)

SHUNTED DEMIXED JACKS

Zo

OUT

Ohm
AM5175D

75

TV

SAT

V/mA

22/0.6

ok

18/500

KHz

ok

B1
40-68
MHz

0,3 dB
-

FM

87.5-108

MHz

VHF

120-470

MHz

UHF

SAT IF

470-862

950-2150-2400

MHz

MHz

0,3 dB
0,5 dB

<2 dB

<2 dB

TECHNICAL INFORMATION
MTIX CATALOGUE

57

Control
ROOM THERMOSTATS AM/A5711 - AM/A5712

These thermostats control the room temperature through an electronic


detector that operates an output relay.
The following parts are on the front part of the devices:
- knob for setting the selected temperature
- LED for indicating the operation status
- commutator for selecting summer/winter

Wiring diagram device AM/A5711

L
L

Technical features common to the 2 devices

power supply 230V a.c. 10% 50/60Hz 0.6W


output contacts 2A 250V a.c.
room temperature setting range: 5 to 30C
recommended installation height from oor:
1.5m (away from heat sources and draughts)
- do not install in boxes where there are dimmers
- max conductor size = 2x2.5mm2
- overall size: 2 modules

N
N

NC NO C
NC NO C

common
heating
air-conditioning

230Va.c.
230Va.c.

Wiring diagram device AM/A5712

Technical features device AM/A5711

- for heating and air-conditioning systems (boilers, fan-coil units, air-conditioners,


fan heaters)
- set up for external summer/winter commutator
- switched output contact

L
L

N
N

NO
NO

Technical features device AM/A5712

- for heating and air-conditioning systems (boilers, fan-coil units, air-conditioners,


fan heaters)
- built-in summer/winter commutator
- output contact NO

58

MTIX

fan-coil units,
circulation pump, etc.

230Va.c.
230Va.c.
127Va.c.
127Va.c.

BACK-LIT DISPLAY ELECTRONIC CHRONOTHERMOSTAT AM5721

The AM5721 Chronothermostat is a ush-mounting device which can be used


for heating and air-conditioning systems; it is possible through several
programming possibilities to adjust the temperature at any time of the day
and in a differentiated manner, every day of the week.
It is possible to choose how to use a standard program (already stored but
can be changed according to the specic needs of the user) or to create a
new one with a simple programming procedure.
A large back-lit display shows you at all times the programme setting, the
status of the system and the temperature of the room. The Chronothermostat
consists of a base used for the system electric connections and a removable
front part to allow the user to execute the programming operations and to
replace the batteries more easily.

The display

Carico acceso
Stato impianto
Estate/Inverno

Temperatura
prevista

Programma
settimanale

Temperatura
misurata

Technical data

Operating temperature: 5C 35C


Power source: 2 LR6/AA 1.5V alkaline batteries
Minimum time between a programmed operation and the next: 15 minutes
Temperature values that can be set: 3C 40C (with a 0.1C minimum interval)
Accuracy of controlled temperature: 0.5C
Battery life: at least 1 year
Flush-mounting or wall-mounting installation
Voltageless output contact rate: 5(3)A
Possibility of connecting an external probe for a temperature with the following
features: R (25C) = 10k BETA = 3435 - max. connection length 5 metres
- Possibility of remote controlling the Chronothermostat (for example, with a telephone switchboard, telephone actuator, burglar alarm system, etc.)
The front side

Profilo giornaliero

Ora

Data

Connections

Max conductor size: 2 x 2,5 mm2

* The correct use of


the probe requires the
application of the sensor on
a surface which gradually
reaches the temperature,
not exposed to heat or solar
radiation sources.

4
1 - Graphic display: displays the messages which determine the
programming operations as well as the system status
2 - Selection Keys: these let you cycle through the functioning
modes inside the menu, if any, while the main screen is being
viewed;
3 - OK Key: accesses the main menu, conrms the selection displayed
or the data entered
4 - Sensor: measures the ambient temperature
5 - C Key: cancels the selection and returns to the previous page; if
held down, it returns to the initial page
6 - Scroll Keys: these let you change the set temperature while the
main screen is being viewed; when inside the menu, you can
scroll the list of the options available

To loads to
be checked

External NTC sensor


connection *

Remote activation
Closed contact = antifreeze mode
Open contact = weekly program
(last selected)

TECHNICAL INFORMATION
MTIX CATALOGUE

59

Control
PROGRAMMER AM/A5766

This daily/weekly cycle programmer enables the automatic connection or


disconnection, with a maximum absorption of 8A, according to a xed time
set by a user.

Wiring diagram

Technical data

60

daily/weekly cycle with 4 daily connections and disconnections


operating voltage: 230V a.c. 10% 50/60 Hz
voltageless switched contact
controllable loads:
2A inductive load
4A uorescent lamps
6A incandescent lamp and ferromagnetic transformers
8A resistive load
minimum time between one operation and the next: 1 minute
charge back-up: 30 days
permanent indication on the liquid cristal display of: the time, day of the week
and connected/disconnected load
display, if required, of the program setting
manual control
max conductor size: 2.5 mm2

MTIX

Audible and luminous


signalling devices
ELECTRONIC BELL AM/A5755/12

The electronic bell has 3 sounds, all of which are continuous and intermittent
and pilot-operated from three different paging locations.
It is also possible to adjust the volume of the required sound with the
controller located at the front.
The 12V power supply can be used with direct current or alternate current.

Wiring diagram

Technical data

- power supply: 12V d.c./a.c. +15% 50/60Hz


- absorption:
150mA with pressed pushbutton
15mA at rest

PULL-OUT EMERGENCY TORCH A5779

The device includes a charger base and a lamp with replaceable back-up
batteries. It turns on automatically when the electrical power goes out. The
lamp unit can be removed so that it can be used as a normal rechargeable
torch.
It also includes two LEDs which indicate the type of function being used
and a slide switch for enabling or disabling the device thereof (this is
important for preventing it from being switched on in case of an intentional
disconnection of the power service).
The battery recharge is also temporarily inactive when the device is disabled
(red LED ON). It is possible to exclude the removal of the lamp unit by
putting in a special lock screw located at the bottom of the device.

Technical data

pull-out emergency torch with automatic switch-on device


charger base with safety connector equipped with a screen
lighting source: white-lighted LED
rechargeable battery: type Ni-MH without memory effect, interchangeable
life: 2 hours
stand-by consumption: 0.4W
power supply: 230/127V a.c. 10% 50/60 Hz - 110V a.c. 10% 60 Hz
max conductor size: 2.5mm2
overall size: 2 modules

Wiring diagram

L
230Va.c.
N

TECHNICAL INFORMATION
MTIX CATALOGUE

61

Emergency
devices
EMERGENCY LAMPS A5774/... - A5776/... - L4784/... - L4786/...

Emergency and lighting


The new high-efciency luminous and long-lasting emergency lamps are
available in two versions: version with the one-function emergency lamp
or the lamp with permanent emergency and lighting. The rst ones start
operating automatically in case of a power supply failure, then they turn off
again when the power is back; the second ones use the emergency function
together with the permanent switch-on to light up rooms that need articial
lighting 24 hours a day, for example corridors or internal stairways without
windows.

Wiring diagram
P = TEST pushbutton (if provided)

Control functions
Every lamp is supplied with a LED, which indicates that there is a ow
of electricity, and a pushbutton that lets you turn it off when used for
emergencies in order to prevent the batteries from uselessly running down,
for example when you intentionally turn off the main switch to carry out
electrical maintenance on the system. When there are several lamps, it is
possible to exclude them with a remote switch.

1 2

1 2

L N

L N

P
230 Va.c.
50 Hz

Wiring diagram for disabling the operation of the emergency lamp


S = remote disabling switch
(1): l = 20m max - 1.5mm2
(2): max 5 x AM5774/ - AM5776/

Spare batteries
The lamps are supplied with batteries placed in the back, easily accessible
for their replacement. In fact, the batteries can be supplied separately as
spare parts.

(1)

(2)

230 Va.c.
50 Hz

(2)

1 2

1 2

L N

L N

Technical features

62

MTIX

Electrical
safety devices
EARTH LEAKAGE THERMAL MAGNETIC CIRCUIT BREAKERS
AM5206S - A5206S
AM5210S - A5210S
AM5216S - A5216S
AM5246S - A5246S
AM5250S - A5250S
AM5256S -A5256S

Automatic thermal magnetic circuit breaker (1 module) device A


Two-pole version with one protected pole. Extends the possibility to use
these automatic devices with single-phase circuits, for which there should
be a two-pole break.

Salvavita automatic earth leakage thermal magnetic circuit breaker (2 mod.) device B
The device has an electronic earth-leakage release which is self-powered through
a built-in rectier. It gives additional protection against direct contact with parts
connected to the power supply. This electronic solution enables the device to detect
earth-fault leakage current with continuous components (earth leakage
type A
) and reduce accidental trips due to line disturbances. A red/green ag
shows the position of the contacts (closed or open). In a system sized according
to the IEC Standards, a correct installation requires a Salvavita upstream of an
automatic earth leakage thermal magnetic circuit breaker with In = 30mA.

Technical features

Tripping features

rated current: 6-10-16A


rated voltage: 230V a.c. 50Hz
rear terminals
max conductor size: 4mm2
overcurrent protection on phase
breaking capacity: In 6A: 1500A 230V a.c.
In 10-16A: 3000A 230V a.c.
- tripping features type C
- differential breaking capacity device B: 500A
- differential rated current device B: 10 mA
- maximum specic pass-through energy I2t (A2s):
In
breaking capacity
6A
10A
1500A
7500
11000
3000A
28000

10000

t(s)

1000

100

10

16A
13000
30000

Wiring diagram device B

230Va.c.

line L

load

0,1

0,01

0,001
0,8

The principle of the above diagram goes for devices A, too.


1

1,5

10

I/In

20

Tripping feature of circuit breakers recorded with cold start to room


temperature Ta = 20C
I = actual current
In = rated current of the switch
A red/green ag shows the position of the contacts (closed or open).

TECHNICAL INFORMATION
MTIX CATALOGUE

63

Electrical
safety devices
FUSECARRIERS AM/A5088
Features of fuses installed

Item
fusecarrier
AM/A5088

Type of
fuse
miniature
glass body

Size of fuse
5x20 mm
6.3x32 mm

Voltage
rating
250V a.c.

Rated
current
max. 10A

Coupling
bayonet

INTERLOCKED SOCKETS AM5114 - AM5130

Interlocked sockets 2 modules


2P+E two-pole thermal magnetic circuit breaker with one protected pole and
interlocked socket.
These assemblies include the following:
a) protection of one pole (phase) and opening of the neutral
b) open switch socket with socket contacts totally separated from the
electric power supply mains (double-pole break)
c) socket/switch interlock. A special mechanism prevents closing the switch
(supplying the socket) if the plug has not been previously plugged in.
It can also prevent pulling out the charged plug (with users device
electrically-powered). As a matter of fact, in this case, the extraction
attempt (with switch closed) will immediately open the switch thereof
(plug still connected to the socket contacts).

64

MTIX

Technical features

- rated current: 10-16A


- rated voltage: 230V a.c.
- max conductor size: 2.5mm2
- breaking capacity: 3000A 230V a.c.
- degree of protection: shielded socket contacts 2.1

Max. conductor
size to terminals
4 mm2

GAS DETECTORS AM/A5731/12 - AM/A5732/12

The range of gas detectors includes:


- methane gas detectors (AM/A5731/12)
- GPL gas detectors (AM/A5732/12)

Technical features

power supply: 12V a.c./d.c. 10%


absorbed power: max 2W
operating temperature: 5 to 40C
loudness level of the alarm signal: 85dB a 1m
operative sensitivity: 10% of the gas explosion level, lower limit

Wiring diagrams

Connection to a gas detector and a signal repeater.


to the solenoid valve to
manual resetting
DETECTOR

230Va.c.
230Va.c.

DETECTOR

REPEATER

Methane and GPL gas detectors comply with standard UNI CEI 70028 and
with the European standard project EN 50194.
All detectors use the latest-generation semiconductor sensors; this feature
makes every device extremely selective on the gas for which it was rated,
thus the possibilities of accidental alarms are reduced.
They are controlled by a microprocessor and are provided with an internal
self-test for signalling possible anomalies of electronic components of the
sensor and of external connections.
A series of LEDs and a audible signalling device indicate proper power
supply, a possible anomaly or an alarm situation.
As required by the Standards, all devices are sensitive to just one type of
gas and clearly show the name of the manufacturer, the type of gas for
which they were made, the recommended replacement date, the guaranteed
period of operation, etc..
All devices are made in a two-module enclosure.
Only the conguration that requires an installation combined with the
repeater and detector is covered by the IMQ - UNI CIG mark of conformity,
according to the Standard UNI CEI 70028.

12Va.c.
12Va.c.

Alarm indications and proper operation


For systems with 3 devices, use transformer item F91/12E
The alarm, failure and proper power supply indication is signalled by
the LEDs and by the audible signalling devices which bear the standard
symbols required by the regulation.

Connection to a gas detector,


a signal repeater and solenoid valve.
DETECTOR

DETECTOR

SOLENOID VALVE
230Va.c.
230Va.c.

12Va.c.
12Va.c.

TECHNICAL INFORMATION
MTIX CATALOGUE

65

IP40 and IP55


enclosures
IP40 ENCLOSURES

These boxes consist of a base and of a cover in which (if required) preconnected snaplock devices can be tted from the back side. This set of
products is suitable for uses in tough and environmentally difcult places
such as roofs, storehouses, basements, etc.
Thanks to their excellent features (resistance to high temperatures and re),
these boxes are suitable for electric systems installed in high-risk places (e.g.
in case of re), as required by the Standards IEC 64-8 section 7. Therefore,
they can be used in buildings built with inammable material (e.g. wood)
or in places containing highly inammable material (thermal power stations,
lumberyards).

IP55 ENCLOSURES

These boxes have a snap-lock front door with an elastic sheath. The IP55
degree of protection is guaranteed by a watertight seal and by a special
snaplock fastening system. These products are generally used in particular
places such as: wet and moist places, places exposed to adverse weather or
water jets (for example in a car-wash).
Technical features of enclosures IP40 and IP55

- Material of boxes IP40: ABS (base and cover)


- Material of boxes IP55:
ABS (base), polycarbonate (cover chassis) and PVC (pliable sheath)
- Temperature range:
-5 to +40C
- Resistance to abnormal heat and re up to 652C
- IMQ approval according to Standard CEI 23-48 (IEC670)

NOTE: The IP55 degree of protection of the protected covers for boxes item
502 and item 503E is obtained when the cover is closed and when the
item is installed on smooth, grooveless and waterproof walls (smooth tiles,
marble).

66

MTIX

USE OF INTERNAL PARTITIONS

Using plastic partitions the space inside the containers can be divided into
compartments for the wiring of electric circuits of different systems (power,
telephony, data transmission, etc.). The containers which can be divided into
compartments are listed in the table.

Use of partitions

item 25701V

Table

Partition
item
25701V

25701

Enclosure
25404/2
25406
25408
25412
25416
25404/2V
25406V
25408V
25412V
25508V
25512V

No. of
partitions
1
1
1
2
3
1
2
1
2
1
2

No. of compartments
which can be made
2
2
2
2
4
2
3
2
3
2
3

ACCESSORIES FOR ENTRY WITH PIPES INTO CONTAINERS IP40 AND IP55

item 25701

fairlead

quick click
pipe clamp

To connect the boxes with the wall piping of the electric system there are
specic accessories such as:
- IP55 rubber elastic fairlead for sheathed cables and piping with diameter from
5mm to 14mm;
- IP55 pipe clamp with gasket for the entry with piping of diameter 16 and
20mm.
These components are easily installed in the knock-out sockets in the sides and
the bottom of the containers.

* To guarantee the IP55 protection rate, it is necessary to x the


wall-mounting box, by inserting screws into the special holes
indicated by the arrow.

TECHNICAL INFORMATION
MTIX CATALOGUE

67

Electronic devices
in protected version
SWITCHES WITH PASSIVE INFRARED PRESENCE DETECTOR

These devices have a passive infrared ray detector, which is sensitive to


the thermal radiation emitted by moving bodies, and a brightness detector.
When people or vehicles move into the eld of action, the device activates
an internal relay to command lighting or presence check systems. Depending
on the type of device, the eld of action can be extended to a maximum
length of 10 m with angular opening between 140 and 270.
The brightness detector allows activation of the relay only when the area

lighting falls below an adjustable threshold.


If the twilight activation is not required, the detector can be deactivated;
in this case the switch only activates with the tripping of the infrared ray
sensor. The length of the switching on can be adjusted by the internal timer:
after the xed time, if the person is no longer in the eld of action, the relay
deactivates.

SWITCHES ITEM 23972N


Coverage range diagram

Diagram for command of an automatic lamp plus a manual point

230Va.c.

Diagram for command of staircase lights with Living Classic, Living


International and Light timers

10m

230Va.c.

68

MTIX

- Rated voltage: 230V 5% 50-60Hz


- Absorption: 1W
- Controllable power:
8A 250V cos 0.1
5A 250V cos 0.4
- Closing time of contact:
Adjustable from 10 to 420s
- Twilight threshold:
Twilight threshold: can be adjusted for continuous tripping, at twilight or night
- Detection:
high density detection with Fresnel lens optical system
- Sensor: positioned in pivoting ball head
- Horizontal spectrum: 140/10m
- Vertical spectrum: 8/10m

Technical features

SWITCHES ITEM 25550/180 AND ITEM 25550/270


Coverage range diagram item 25550/180

Technical features

- Degree of protection: IP54


- Supply voltage: 230V a.c. 50Hz
- Controllable power:
1000VA (uorescent lamps)
2000VA (transformers and quartz-iodine lamps)
2000W (resistive loads)
- Closing time of contact:
Adjustable from 12 seconds to 16 minutes
- Twilight threshold:
adjustable from 10 to 4000 lux
- Detection:
high density detection with Fresnel lens optical system
- Sensor: positioned in pivoting ball head
- Horizontal spectrum:
180/16m (Item 25550/180)
270/16m (Item 25550/270)
- Minimum installation height: 1.7m

180

item 25550/180

2,4 m

Wiring diagram for automatic control of a lamp


3m

8m

16 m

Coverage range diagram item 25550/180


L

270

230Va.c. N

item 25550/270

2,4 m

Installation possibilities
3m

8m

16 m

item 25550/180
item 25550/270

item 25550/180
item 25550/270

item 25550/270

TECHNICAL INFORMATION
MTIX CATALOGUE

69

RESIDENTIAL SERIES - IDROBOX


Dimensional
data
MTIX COVER PLATES
120

132

84

191

84

144

84

120

84

91

AM4802...

AM4803...

AM4804...

191

84

84

AM4826...

AM4806L

IDROBOX IP40 ENCLOSURES

A
76
76
76
76

25401
25402
25403
25404

B
76
76
100
132

C
55
55
55
55

A
76
76
76
76
76

25404/2
25406
25408
25412
25416

B
132
188
227
331
434.5

C
55
55
55
55
55

C
C

A
132
188
162
248

25404/2V
25406V
25408V
25412V

B
76
76
132
132

C
55
55
55
55

25501
25502
25503
25504

B
76
76
100
132

C
63
63
63
63

A
76
76
76
76

IDROBOX IP55 ENCLOSURES

25508V
25512V

IDROBOX PROTECTED COVERS

7676

25602 - 25602S

70

98
98

76
76

76

98
98

98

76

76
76
76

122
122

98

122

98,2 98,2
98,2

25

99,8 99,8
99,8

25603 - 25603S

MTIX
115

115
115

81

8181

27

2727

2525

A
157
238

B
132
132

C
63
63
C

IDROBOX

92

70
INFRARED PRESENCE
SWITCH

92

70

80

82

165

80

82

50

165

50

135
135

23972N

80

53

72

53

72

25550/180
25550/270

Supporting
80frame for 25550/270
JUNCTION BOXES
A

58

A
94
142

23983
23984

82

C
82
130

D
53
53

IDROBOX PLUS
68
64

68

76

162

76

64

76
87

76
87

76

26200
26003 - 26005

26055
76
52

93

1 01

76

125

49

26108L - 26108N - 26108T

26066

109

48
28.5
24

135

DIMENSIONAL DATA
MTIX CATALOGUE

71

BTicino SpA
Via Messina, 38
20154 Milano - Italia
www.bticino.com

Middle East
countries
Dubai

Iran

Saudi Arabia

JAFZA 15 - Ofce 601,


Jebel Ali Free Zone
P.O. BOX: 61415, Dubai U.A.E.
Tel. +971 4 8816178
Fax +971 4 8818145
www.legrand.ae

Legrand
Alborz Electrical Industries Ltd n. 45,
Kouhe Noor Avenue 7 TH Street
O. Motahari Avenue
15876 Teheran
Tel: +98 21 873 94 57/86 70
Fax:+98 21 873 79 03

Legrand
PO Box 51712 - Jeddah 21553
Tel: +966 2 651 28 48
Fax:+966 2 651 74 34

Egypt
EMB Electrical Industries S.A.E.
Pyramids Heights Ofce Park Km 22
Cairo/Alexandria
Desert Road Building 9C - Giza
Tel: +20.25.36.00.00
Fax:+20 .25.36.00.01
www.bticino.com

Jordan
Legrand Near East Regional Ofce
142 Arar Street, Wadi Saqra
PO BOX 501, 11118 Amman
Tel. +962 (0)6 465 5902
Fax +962 (0)6 465 5903
ofce.amman@legrandelectric.com

Syria
Legrand SNC representative ofce
Bldg 66, Omar Hamad Avenue,
Al Rawda 1st oor, apt. 3
PO BOX 10334, Damascus
Tel. +963 11 33 22 920
Fax +961 11 33 22 512
ofce.syria@legrandelectric.com

Lebanon

This booklet deletes and replaces the previous one with reference MX06C/TGB.
BTicino S.p.A. reserves at any time the right to modify the contents of thi booklet and to communicate,
in any form and modality, the changes brought to the same.

version 06/2008

Legrand SNC representative ofce


Sodeco Square Center
Bloc B, 1st oor
Damascus Road, Beirut
Tel. +961 1 422 166
Fax +961 1 422 167
ofce.lebanon@legrandelectric.com