BA - C 250

Skid Mounted Diesel Driven


BEP 350 liter/sec
Head 180 meters
GENERAL SPECIFICATIONS
Power Drive
Pump
Suc on Coupling
Discharge Coupling
Engine Model
Horse Power
Fuel Tank
B.E.P.

:
:
:
:
:
:
:
:

MD - 900
BA - C250 H45
12 DIN
10 ANSI
CAT C32 ACERT
950 HP
4.000 liters
Flow 350 lps
Head 180 m

FEATURES
Eco Green Environment
Having embedded TFS pump with Dragflow manufacturer
which having close co-opera on with engine manufacturers result in pumps which will meet the strictest of future
emission regula ons. Our highly ecient, fully oil spill free
pumps oer the lowest fuel consump on available in the
market, maximizing all means for reducing the carbon
footprint.

TFS Mine Dewatering


The TFS Mine dewatering range of pumps have been
designed with a clear focus on reliability, eciency and
durability. Featuring a 100% mechanical priming system,
the TFS Series pumps quickly prime and re-prime, event
from dry condi ons.
The heavy build style of both pump and pla orm make
the TFS mine Dewatering range perfect for use in the
Mining Market applica ons.

After sales service & product support


Single supplier for parts, spares & accessories
Dedicated customer help-desk (24h service)
Dedicated service department in-house
Global parts distribu on network
Op onal global on-site servicing available
Extensive training op ons available (technical
& commercial), on-site or in-house

World-class performance
The TFS range is built to be deployed on the most
demanding dewatering and sewage bypassing applicaons. Using high eciency pumps and state-of the art
diesel engines, the pumps oer maximum performance
at minimal cost, fully in-sync with the company philosophy of Lowest cost of ownership.

Advantage Features
Reliability
Produc vity & Economy
Easy Maintenance
Operator Environment
Safety

Complete package designed & built by


TFS Engineering
Complete in-house design & produc on
Over 10 years of experience in the market
Complete tes ng facility in-house
Contemporary & func onal design
Durable & eco-friendly materials
Custom builds available

info@limeda.com

BA - C 250
Skid Mounted Diesel Driven
BEP 350 liter/sec
Head 180 meters
PUMP PERFORMANCE

1770 RPM and Impeller Size 673 mm

info@limeda.com

BA - C 250
Skid Mounted Diesel Driven
BEP 350 liter/sec
Head 180 meters
PUMP PACKAGE STANDARD INCLUSSION
Pump Specifications
Type
Max. Flow
Max. Pressure
Conecon
Solids Handling
Impeller Type
Impeller Material
Casing Material
Pump Sha
Mechanical Seal
Priming System

BBA
PRIMING
SYSTEM

Type
Air handling capacity
Max. vacuum
Drive
Float box
Float
Non return valve

:
:
:
:
:
:
:
:
:
:
:

BA-C250 H45
1750 m/hour (7.700 US GPM)
250 mwc (800 .)
10 DN x 8 ANSI
60 mm (2.38)
Close impeller
Stainless Steel CA-6NM
Ducle Iron GGG70
Stainless Steel 17-4 Ph
Cycloseal
MP100

:
BBA MP100 Diaphragm pump
:
100 m/hour (59 CFM)
:
8.5 m (29 inHg)
: Toothed belt (connuous drive)
:
Aluminium
:
SSte 304
:
Ducle iron

Engine Specifications

Engine brand
Engine type
Flywheel power
Max. engine speed
Fuel consumpon
Displacement
Number of cylinders
Aspiraon
Exhaust emission US

:
:
:
:
:
:
:
:
:

Caterpillar
C32 ACERT
950 Hp
2.100 RPM
205 g/kWh at 1800 RPM
32.1 L (1958.9 in3)
6
Turbocharged aercooled
Tier 4

info@limeda.com

BA - C 250
Skid Mounted Diesel Driven
BEP 350 liter/sec
Head 180 meters
Platform Specifications
Plaorm base
Base type
Dimensions (L x W x T)
Fuel capacity
Basic frame
Liing point
Exhaust system
Fuel system

:
:
:
:
:
:
:
:

Skid
F-400
7.400 x 2.500 x 600 mm
4.000 liters
UNP and Bisalloy
Central liing beam
Mounted in engine
Fuel tank 700 L net (180 US Gallon)
Fuel tank cap 60 mm
Electronic fuel injecon
system (ACERT)
Fied with water separator &
extra in-line fuel filter

TFS Smart Controller


Auto start/stop system
Complete engine management
via engine control system
CAN display
Engine load monitor
Fuel Consumpon monitor
Turbo boost monitor
Engine Oil pressure monitor
Engine temperature monitor
Overload Protecon
Hour meter
Programmable service interval
control

Automac engine speed


ramping to flow/pressure/me
Pump vacuum pressure
monitoring
Discharge pressure monitoring
No Flow Protecon
Pump Volute Temperature
monitoring
External start stop facility
Design to provide stage pump
dewatering with opmum
control

Pump Smart
Pump health monitoring status
warning and error code log.

info@limeda.com

BA - C 250
Skid Mounted Diesel Driven
BEP 350 liter/sec
Head 180 meters
Fast Fill Service
Engine Oil and Coolant Drain Fast Fill Service
Centralized fast filling to drain and
fill oil and coolant engine

Safety
Loto Box
Centralized electrical
safety system, Lock Out
Switch, Emergency
shutdown and ba ery
jump start

Non Return Valve


Safety valve to guard back
pressure from piping in
pumping.
Component:
Stainless Steel or Duct
cas ng material.
Thermal insulation
blanket
Blanket to hold exhaust
line temperature as safety
protec on

Coolant level switch


To ensure the coolant level
in the radiator and protect
the engine system from
over-hea ng

Optional Exclussion

TFS Fire Extinguisher


Overall height
Tube diameter
Working temperature
Pressure in the tube
Test pressure
Spray me
Spraying distance
Eec ve spraying
Total weight
Fire ra ng

635 mm
160 mm
-20C up to 60C
15 bar
25 bar
23 seconds
4 m up to 13 m
95%
11.5 Kg
12a 60b

:
:
:
:
:
:
:
:
:
:

Fuel Fast Fill


Wiggins or Banlaw Fuel Fast Fill
a ached on request.

info@limeda.com

BA - C 250
Skid Mounted Diesel Driven
BEP 350 liter/sec
Head 180 meters
Lifting Point
Central Liing Beam and 4 lugs point
(oponal)

Bull Bar Guard


Push point when driven/move using
excavator, bulldozer, etc.

Drag Chain
Use to move the pump staon by dragging
with bulldozer, etc.

Blasting Protection
Protect external blasng and either engine
fault or pump crash

Pump Separator
Separaon between the engine and pump,
if the pump leaked, engine is not exposed
to water

Jib Frame
Hold the sucon hose

Suction hose winch


Operated by automac
winch with disc brake

Side step and work platform


Stepside with ladder that hold operator for
conve-nience safety movement acvies
when working with pump or pontoon

Heavy Duty Hose Strainer

info@limeda.com

BA - C 250
Skid Mounted Diesel Driven
BEP 350 liter/sec
Head 180 meters
ADVANTAGE FEATURES

Cycloseal
Cycloseal design, with its unique deflector
vanes, works with the impeller back-vanes to
create a cycloac on. This ac on removes solids
and abrasive material from the seal area.

Run-dry option
All of the pumps in the BA series are
designed to run dry for longer periods.
The mechanical seal is cooled by an
external oil circula on system.

SAE Direct mounted pump


Highest eciency pump
Never has mis-alignment
Longer bearing life in pump
Longer seal life in pump
No drive coupling issues

Interchangeable parts
Modular construc on
to ensure minimal
spare part stock level

info@limeda.com