Академический Документы
Профессиональный Документы
Культура Документы
2008, edition 1
Cable
size
mm
7.2 kV
Instructions:
Choose cable size, voltage level and type
(indoor or outdoor) in the upper table.
The number gives the second part of
the Article No. for the correct type of accessory
for the choice made.
Accessories are specified in the lower table.
Example:
1 x 240 mm 17.5 kV cable, outdoor termination,
gives number 1121 which stands for:
Article No. 6234,1121 = SOT 244-3 T
12 kV
17.5 kV
24 kV
36 kV
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
In- Outdoor
16
1100
1114
1119
25
1100
1119
1114
1119
1112
1117
35
1100
1119
1114
1119
1112
1117
1113
1118
50
1100
1119
1112
1117
1112
1117
1113
1118
70
1101
1117
1112
1117
1112
1117
1113
1118
1123
95
1101
1117
1112
1117
1112
1117
1113
1120
1123
120
1101
1117
1112
1117
1113
1117
1113
1120
1123
150
1101
1117
1113
1117
1113
1120
1116
1121
1123
185
1101
1117
1113
1120
1113
1120
1116
1121
1123
240
1109
1120
1115
1120
1116
1121
1116
1121
1124
300
1109
1120
1116
1121
1116
1121
1116
1122
1124
400
1109
1120
1116
1121
1116
1122
1116
1122
500
1115
1122
1116
1122
1116
1122
630
1115
1122
1116
1122
Type
Article
No.
6234,
Designation
Diameter
over insulation
mm
Size of
copper braid
mm
Picture
Indoor
1100
SOT 101-3 R
10.5 - 15
10
Indoor
1101
SOT 102-3 R
12.9 - 25.8
10
Indoor
1109
SOT 103-3 S
21.5 - 34.9
22
Indoor
1112
SOT 241-3 R
15 - 28
10
Indoor
1113
SOT 241-3 S
15 - 28
22
Indoor
1114
SOT 241A-3 R
11 - 15
10
Indoor
1115
SOT 242-3 S
25 - 39
22
Indoor
1116
SOT 242-3 T
25 - 39
22
Outdoor
1117
SOT 243-3 R
15 - 24
10
Outdoor
1118
SOT 243-3 S
15 - 24
22
Outdoor
1119
SOT 243A-3 R
11 - 15
10
Outdoor
1120
SOT 244-3 S
22 - 33
22
Outdoor
1121
SOT 244-3 T
22 - 33
22
Outdoor
1122
SOT 245-3 T
31 - 40
22
In/outdoor
1123
SOT 361-3 T
26 - 39
22
In/outdoor
1124
SOT 361-3 U
26 - 39
35
Instructions:
Choose cable size, voltage level and type
(indoor or outdoor) in the upper table.
The number gives the second part of the
Article No. for the correct type of accessory for
the choice made.
Accessories are specified in the lower table.
Example:
3 x 240 mm 17.5 kV cable, outdoor termination,
gives number 1095 which stands for:
Article No. 6234,1095 = SOT 244-3 TB
Cable size
mm
7.2 kV
12 kV
17.5 kV
24 kV
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
In- Outdoor
1081
1089
1085
25
1081
1085
1089
1085
1090
1086
35
1081
1085
1089
1085
1090
1086
1092
1096
50
1081
1085
1090
1086
1091
1087
1092
1096
70
1082
1086
1091
1087
1091
1087
1092
1096
1098
95
1083
1087
1091
1087
1091
1087
1092
1088
1098
1083
1087
1091
1087
1092
1087
1092
1088
1098
150
1083
1087
1092
1087
1092
1088
1094
1095
1098
185
1083
1087
1092
1088
1093
1088
1094
1095
1098
240
1084
1088
1093
1088
1094
1095
1094
1095
1099
300
1084
1088
1094
1095
1094
1095
1094
1097
1099
400
1084
1088
1094
1095
1094
1095
1094
1097
Designation
Indoor
1081
Indoor
1082
Indoor
Indoor
Outdoor
120
Article
No.
6234,
36 kV
16
Type
Diameter
over
insulation
Diameter
over outer
jacket
Maximum
length*
L
mm
Size of
copper
braid
mm
Picture
SOT 101-3 RC
10.5 - 15
24 - 60
500
3 x 10
SOT 102-3 RC
12.9 - 25.8
24 - 60
500
3 x 10
1083
SOT 102-3 RD
12.9 - 25.8
48 - 110
500
3 x 10
1084
SOT 103-3 SD
21.4 - 34.9
48 - 110
500
3 x 22
1085
SOT 243A-3 RA
11 - 15
24 - 60
1450
3 x 10
Outdoor
1086
SOT 243-3 RA
15 - 24
24 - 60
1450
3 x 10
Outdoor
1087
SOT 243-3 RB
15 - 24
48 - 110
1450
3 x 10
Outdoor
1088
SOT 244-3 SB
22 - 33
48 - 110
1450
3 x 22
Indoor
1089
SOT 241A-3 RC
11 - 15
24 - 60
550
3 x 10
Indoor
1090
SOT 241-3 RC
15 - 28
24 - 60
550
3 x 10
Indoor
1091
SOT 241-3 RD
15 - 28
48 - 110
550
3 x 10
Indoor
1092
SOT 241-3 SD
15 - 28
48 - 110
550
3 x 22
Indoor
1093
SOT 242-3 SD
25 - 39
48 - 110
550
3 x 22
Indoor
1094
SOT 242-3 TD
25 - 39
48 - 110
550
3 x 22
Outdoor
1095
SOT 244-3 TB
25 - 33
48 - 110
1450
3 x 22
Outdoor
1096
SOT 243-3 SB
15 - 24
48 - 110
1450
3 x 22
Outdoor
1097
SOT 245-3 TB
31 - 40
48 - 110
1450
3 x 22
In/outdoor
1098
SOT 361-3 TB
26 - 39
48 - 110
1510
3 x 22
In/outdoor
1099
SOT 361-3 UB
26 - 39
48 - 110
1510
3 x 35
* Maximum length including termination measured from the crutch of the cable to the end of the XLPE-insulation.
ABB AB
Kabeldon
Box 531
SE-441 15 Alingss, Sweden
Tel: +46 322 770 00
Fax: +46 322 770 01
www.abb.se/kabeldon