Вы находитесь на странице: 1из 6

MAZAK M PLUS/ T PLUS Memory Upgrade

Installation Instructions

2011-- Memex Automation Inc. All rights reserved.


No part of this manual may be reproduced without express written consent of Memex Automation Inc.
Memex does not assume any liability for the use of this manual.

ISO Doc M100772

Table of Contents
REMARKS: .................................................................................................................................................. 3
Getting to Privilege Mode. ........................................................................................................................... 3
Changing Memory Area: .............................................................................................................................. 3
Reinitializing memory: ................................................................................................................................. 4

2|Page

Instructions for control configuration for the Memex 1.5MB Memory Upgrade for the
MAZAK T PLUS

REMARKS:
The T-plus control is similar to the T32 control's method of initializing the memory. The
1131 procedure to put the control into privileged mode and the saving/loading of
parameters to EEPROM are slightly different. These differences will be explained in this
bulletin.
Similar to the T32, the T-plus is divided Into 4 different memory areas.
Such as:
1. Area 00 8- CNC controls internal canned cycles.
2. Area 01 - Machine macros area used for Slant ATC machines to control the Caxis when not an integral spindle. Also, movement commands for tool magazine
on Integrex type machines.
3. Area 10 - Part program area.
4. Area 11 - Setup area for part programs, Gets saved normally during download of
part programs depending on 157 bit 1.To gain access to these areas is
accomplished by first getting into the controls privileged mode. Next, go to
Program File where a new Device Change" menu key will now appear.

To do this on T-plus:

Getting to Privilege Mode.


1) Select Param menu key.
2) Press the extreme right menu key.
3) Type in 1131 and press Input.
4) You are now In privileged mode, The menu button will not highlight as on the T32
control.

Changing Memory Area:


5) Once In privileged mode, select Program page.
6) Select Program File menu key.
7) Press Device Change menu key.
8) Type in the 00, 01, 10 or 11 memory area.

3|Page

Reinitializing memory:
The procedure for Reinitializing memory is as follows:
1) Back up all data. Make sure you check the 01 memory area to see if any machine
programs are there. Save Parameters into EEPROM.
A) Do previous procedure to get to privileged mode.
B) Select Program menu key. ,
C) Select Program File menu key.
D) Press Device Change menu key.
E) Type in 01 and Input. This will display any programs. If there are programs, then
please save them.
2) Power off machine.
3) Flip dip switch 1 and 3 on QX141to the right hand side.
4) Power on control, and you should see the two green LEDs I & 2 go out after about 30
seconds.
5) Power off the control
6) Reset dip switches 1 & 3 to the left.
7) Power on the control.
8) Next, go to User parameter arid set I1 to 2(CMT BAUD) and I65 to Bit 0=1.
Next, reload parameter information. Or, reload the parameters from EEPROM.
A) Go to Diagnose page.
B) Select Version menu key.
C) Press Diagnose Monitor menu key.
D) Select Memory EEPROM menu key.
E) Bring cursor down to EEPROM.
F) Enter 2(Load) and then Input. Then press START. This will now bring
parameters from EEPROM.
Note: It would be a good idea to save to EPROM before doing re-initialization.
4|Page

8.5) Make sure parameters OP38-OP47 are setup correctly. If they are not setup
correctly you will continue to get Alarm #442
9) Power machine off,
10) Wait about 10 seconds & power on again.
11) Go into privileged mode.
12) Go to Diagnose page and select Data Erase menu key. Select all the tool data, tool
offset, etc. by using the menu keys to highlight them.. You must use the --> key to get to
the program, maintenance check, system program.
Note: System program is the memory 00 area. Then key in -9999 & press Input.
13) Reload programs and any other backed up information.
14) If a 218 alarm appears, then flip the chuck Internal/external switch and press
footswitch for chuck(s).

5|Page

Memex Automation Inc.


200 3425 Harvester Rd.,
Burlington, ON L7N 3N1
Canada
www.memex.ca
Sales: 905-635-3043
Support: 905-635-3041

Thank you for using Memex as your


Manufacturing Connectivity Solution

ISSO9000\M100772 Mazak M+ and T+ Memory upgrade.doc