DISEO POR FEXION VP - PISO 1

Calidad del concreto

f'c (kg/cm2)

Pb = 0,851*(f'c/fy)*6300 / (6300+fy)
As max = 0,75*Pb*b*d
Acero positivo
As min = Pmin*b*d

Mu neg (kg-m)
Mu pos (kg-m)
Mu / vigueta (kg-m)
Base "b" (cm)
Peralte "d" (cm)

280

Acero Grado 60

ACEROS MXIMOS Y MINIMOS


0.0289
29.2613
Acero
4.5000
negativo

Pmin=14 / fy
As max = 0,75*Pb*b*d
As min = Pmin*b*d

DISEO DE LAS SECCIONES DE MOMENTO MAXIMO NEGATIVO Y POSITIVO


APOYO A TRAMO A-B APOYO B TRAMO B-C APOYO C
5906.346
28757.386
27622.651
21112.447
20930.178
5906.346
21112.447
28757.386 20930.178 27622.651
25.000
25.000
25.000
25.000
25.000
54.000
54.000
54.000
54.000
54.000

El area de acero se calcula despejando la ecuacion: (*fy2 / 1,7*f'c*b)As2 - (*fy*d)As +


As requerido (cm2)
2.950
11.157
15.699
11.052
15.004
21"
31"
21"
31"
25/8"+13/8"
As colocado (cm2)
4.670
10.140
15.210
10.140
15.210
a = As*fy / 0,85*f'c*b (cm)
3.296
7.158
10.736
7.158
10.736
Mn = *As*fy*(d - a/2) (kg-m)
9241.448 19326.034 27960.250 19326.034 27960.250
s = (1*d - a)*0,003 / a
0.039
0.016
0.010
0.016
0.010

As neg

As pos

As negativo
As positivo

necesario
colocado
necesario
colocado
exigidas

Resistencias
negativas

suministradas

Resistencias
positivas

suministradas

exigidas

APOYO A TRAMO A-B APOYO B TRAMO B-C APOYO C


2.950
15.699
15.004
4.670
15.210
15.210
11.157
11.052
10.140
10.140
5906.346
28757.386
27622.651
9241.448
27960.250
27960.250
21112.447
20930.178
19326.034
19326.034

ESTIMACION DEL FACTOR DE SEGURIDAD


Los aceros negativos y positivos colocados se aproximan lo suficiente a los necesarios.

Es claro que la seccion que gobierna la resistencia del aligerado, si se aceptan los resulatdos del analisis, es la de mome
tramo (A-B), donde se presenta defecto del acero (10,140 colocado contra 11,157 necesario), en consecuencia el factor d
frente a la falla por flexion sera (Metodo aproximado de los coeficientes).
Wu =
5031.630
(1/11)*Wu*(6,5)^2 = 19326,034
F.S. =

(1/11)*Wu*(6,5)^2 = 19326,034

F.S. =
Wservicio =
3903.5
Si se hubieran proporcionado areas de acero exactamente iguales a las exigidas, el factor de seguridad global, hubiera sid
Wu =
6174
F.S. =
Wservicio =
3903.5
El haber modificado el area de acero en el primer tramo, modifica el factor de seguridad de 1,757 a 1,432, considerando a
de calculo.
,

ADHERENCIA Y ANCLAJE
LONGITUDES DE ANCLAJE EN TRACCION - BARRAS INFERIORES - NORMA E-0,60
1). Ld >= 0,06Ab*fy / f'c^0,5
fy (kg/cm2)
4200
2), Ld >= 0,006db*fy
f'c (kg/cm2)
280
3), Ld >= 0,30m
Ld (cm)
BARRA (")
db (cm)
Ab (cm2)
1),
2),
5/8
1.59
1.98
29.81
40.01
3/4
1.91
2.85
42.92
48.01
1
2.54
5.07
76.31
64.01

LONGITUDES DE ANCLAJE EN TRACCION - BARRAS SUPERIORES - NORMA-E-0,60


1), L'd >= 1,4*Ld de barras inferiores
fy (kg/cm2)
4200
2), L'd >= 0,30m
f'c (kg/cm2)
280
Ld (cm)
BARRA (")
5/8
3/4
1

db (cm)
1.59
1.91
2.54

Ab (cm2)
1.98
2.85
5.07

1),
29.81
42.92
76.31

2),
40.01
48.01
64.01

ANCLAJE CON GANCHO ESTANDAR - NORMA E-0,60


1), Ldg >= 318*db / f'c^0,5
fy (kg/cm2)
2), Ldg >= 8db
f'c (kg/cm2)
3), Ldg >= 0,15m
Ldg (cm)
BARRA (")
db (cm)
Ab (cm2)
1),
2),
5/8
1.59
1.98
30.17
12.70
3/4
1.91
2.85
36.20
15.24
1
2.54
5.07
48.27
20.32

L'd (cm)
1),
56.01
67.21
106.83

4200
280

DISEO POR CORTE VP - PISO 1


f'c (kg/cm2)

280

fy (kg/m2)

TRAMO
WD (kg/m)
WL (kg/m)
CORTANTE
d (peralte)
b (base)
Vu (kg/cm2)
Vc (kg/cm2)
Vs (kg/cm2)
Av (cm2)
s (cm)
Vs lim
s max

DISEO PARA LAS SECCIONES DE CORTANTE MAXIMA Y MINIMA POSITIVA


A- B
B-C
C-D
4261.5
4261.5
3217.5
5479.5
5479.55
5479.55
1912.5
1912.5
2985.75
2344.5
2344.5
2344.5
16146.098
24470.481 26014.035 26830.873 25638.682
23886.08
54
54
54
54
54
54
25
25
25
25
25
25
12812.138 21136.521 22664.280 22605.913 21413.695 19661.093
10176.714 10176.714 10176.714 10176.714 10176.714 10176.714
3100.499 12893.890 14691.254 14622.587 13219.977
11158.093
1.42
1.42
1.42
1.42
1.42
1.42
103.872
24.977
21.922
22.025
24.361
28.863
24848.803 24848.803 24848.803 24848.803 24848.803 24848.803
27
27
27
27
27
27

Si Vc Vc , entonces se utilizara estribos mnimos, con un espaciamiento que no exceda del men
s max = Av*fy / 0,2*f'c*bw
s max = Av*fy / 3,5*bw

Av : area proporcionada por los

Si Vc 0,5*Vc , entonces no se necesita ningun refuerzo por corte, salvo los estribos de montaje.
Si Vc > Vc , es necesario refuerzo por corte.
Vs = Vu/ - Vc

Vs : Resistencia al corte sumini

Vs 2,1*f'c*bw*d

Verificacion de la resistencia al

Vs Vs lim
Vs lim = 1,1*f'c*bw*d

SI
Vs Vs lim

estribos mnimos
L'

Vs
Vu
Vc
Lo
estribos a s variable
Xo
cara del apoyo

s = Av * fy * d / Vs
Vs = Vu / - Vc
Vu = V - W*d

de montaje

Vu : Cortante de diseo
d : peralte de la viga
W : carga distribuida en la viga, hasta una distancia d.
V : fuerza cortante.
Vc = *(0,53*f'c)*bw*d
Vc : Resistencia al corte suministrada por el concreto
: factor de reduccion de resistencia al corte (0,85)
bw : base de la viga
TRAMO
CORTANTE
Lo (cm)
L' = L" (cm)
Xo (m)
s (cm)
13/8" @ s cm
n3/8" @ 18 cm
n3/8" @ 22 cm
n3/8" @ 25 cm
n3/8" @ 27 cm
verificaion
s max (cm)

A- B
B-C
C-D
16146.098
24470.481 26014.035 26830.873 25638.682
23886.08
42.686
177.515
201.307
158.860
143.621
121.221
82.416
82.416
82.027
65.035
65.035
65.035
2.615
3.963
4.194
3.429
3.277
3.053
ESPACIAMIENTO DE ESTRIBOS 3/8" EN Lo
27.000
24.977
21.922
22.025
24.361
27.000
5.000
5.000
5.000
5.000
5.000
5.000
0
0
0
0
0
0
0
0
5
4
0
0
0
5
2
1
4
0
1.000
1.000
1.000
1.000
1.000
4.000
ok
ok
ok
ok
ok
ok
ZONA DE ESTRIBOS MINIMOS 3/8" EN L'
68.16
68.16
68.16
68.16
68.16
68.16
resto 3/8" @ 30 cm

VP - PISO 1
fy (kg/cm2)

Pmin=14 / fy
As max = 0,75*Pb*b*d
As min = Pmin*b*d

4200

0.003333
29.2613
4.5000

MO NEGATIVO Y POSITIVO
TRAMO C-D APOYO D TRAMO D-E APOYO E
27405.079
5787.500
15198.564
27022.440
15198.564 27405.079 27022.44
5787.5
25.000
25.000
25.000
25.000
54.000
54.000
54.000
54.000

y2 / 1,7*f'c*b)As2 - (*fy*d)As + Mu = 0
7.849
14.871
21"
31"
10.140
15.210
7.158
10.736
19326.034 27960.250
0.016
0.010

14.639
2.890
31"
25/8"+13/8"
15.210
4.670
10.736
3.296
27960.250
9241.448
0.010
0.039

En ningun caso el As calculado es


mayor al As max, por tanto no se
necesita acero en compresin

Donde s > y, para todos los tramos,


entonces se garantiza la fluencia en el
acero de refuerzo

Si s y, entoces se garantiza la fluencia del acero


Si s y, entoces el acero no fluira, falla a compresion
y = fy / Es = 0,0021

TRAMO C-D

APOYO D TRAMO D-E APOYO E


14.871
2.890
15.210
4.670
7.849
14.639
10.140
15.210
27405.079
5787.5
27960.250
9241.448
15198.564
27022.44
19326.034
27960.250

DAD

dos del analisis, es la de momento positivo en el


o), en consecuencia el factor de seguridad de la viga
1.432

1.432

de seguridad global, hubiera sido.


1.757
1,757 a 1,432, considerando aceptable para efectos

NCLAJE

Ld : longitud de desarrollo
Ab : seccion de la barra de refuerzo longitudinal
Para las tres ecuaciones se toma el mayor valor

Ldg : longitud de desarrollo en gancho


db : diametro de la barra de refuerzo longitudinal
Se tomara el valor maximo de las tres ecuaciones

4200

IMA POSITIVA
D-E
4261.5
4261.5
2344.5
2419
28779.427 18624.072
54
54
25
25
25212.187 15016.602
10176.714 10176.714
17688.791
5693.986
1.42
1.42
18.207
56.561
24848.803 24848.803
27
27

Para todos los casos Vu > Vc , se


necesita refuerzo por corte.
Como Vs < Vs lim , s max sera igual a
d / 2 o 60cm

miento que no exceda del menor de los dos siguientes:

Av : area proporcionada por los estribos colocados

salvo los estribos de montaje.

Vs : Resistencia al corte suministrada por el acero

Verificacion de la resistencia al corte del acero

s max = d/2

(0,60m)

s max = d/4

(0,30m)

de montaje
L"
0,5Vc

D-E
28779.427 18624.072
227.603
72.448
77.026
76.167
4.357
2.788
18.207
5.000
4
3
2
1.000
ok

27.000
5.000
0
0
0
2.000
ok

68.16

68.16

aso el As calculado es
s max, por tanto no se
acero en compresin

y, para todos los tramos,


garantiza la fluencia en el
ero de refuerzo

a compresion

DISEO POR FEXION VP - PISO 2


Calidad del concreto

f'c (kg/cm2)

Pb = 0,851*(f'c/fy)*6300 / (6300+fy)
As max = 0,75*Pb*b*d
Acero
positivo As min = Pmin*b*d

Mu neg (kg-m)
Mu pos (kg-m)
Mu / vigueta (kg-m)
Base "b" (cm)
Peralte "d" (cm)

280

Acero Grado 60

ACEROS MXIMOS Y MINIMOS


0.0289
29.2613
Acero
4.5000
negativo

Pmin=14 / fy
As max = 0,75*Pb*b*d
As min = Pmin*b*d

DISEO DE LAS SECCIONES DE MOMENTO MAXIMO NEGATIVO Y POSITIVO


APOYO A TRAMO A-B APOYO B TRAMO B-C APOYO C
6907.078
28623.065
26664.540
19898.672
33164.836
6907.078
19898.672 28623.065 33164.836 26664.54
25.000
25.000
25.000
25.000
25.000
54.000
54.000
54.000
54.000
54.000

El area de acero se calcula despejando la ecuacion: (*fy2 / 1,7*f'c*b)As2 - (*fy*d)As + Mu


As requerido (cm2)
3.462
10.464
15.617
18.480
14.423
21"
31"
31"
31"
25/8"+13/8"
As colocado (cm2)
4.670
10.140
15.210
15.210
15.210
aMn
= As*fy
/ 0,85*f'c*b- a/2)
(cm)
3.296
7.158
10.736
10.736
10.736
= *As*fy*(d
(kg-m)
9241.448 19326.034 27960.250 27960.250 27960.250
s = (1*d - a)*0,003 / a
0.039
0.016
0.010
0.010
0.010

As neg

As pos

As negativo
As positivo
Resistencias
negativas
Resistencias
positivas

necesario
colocado
necesario
colocado
exigidas
suministradas

exigidas
suministradas

APOYO A TRAMO A-B APOYO B TRAMO B-C APOYO C


3.462
15.617
14.423
4.670
15.210
15.210
10.464
18.480
10.140
15.210
6907.078
28623.065
26664.54
9241.448
27960.250
27960.250
19898.672
33164.836
19326.034
27960.250

ESTIMACION DEL FACTOR DE SEGURIDAD


Los aceros negativos y positivos colocados se aproximan lo suficiente a los necesarios.

Es claro que la seccion que gobierna la resistencia del aligerado, si se aceptan los resulatdos del analisis, es la de mome
el tramo (B-C), donde se presenta el mayor defecto del acero (15,210 colocado contra 18,480 necesario), en consecuenci
seguridad de la viga frente a la falla por flexion sera (Metodo aproximado de los coeficientes).
Wu =
10588.497
(1/16)*Wu*(6,5)^2 = 27960,250
F.S. =

(1/16)*Wu*(6,5)^2 = 27960,250

F.S. =
Wservicio =
3807
Si se hubieran proporcionado areas de acero exactamente iguales a las exigidas, el factor de seguridad global, hubiera sid
Wu =
5965
F.S. =
Wservicio =
3807
El haber modificado el area de acero en el 2do tramo, modifica el factor de seguridad de 1,741 a 3,090, considerando ace
efectos de calculo.

ADHERENCIA Y ANCLAJE
LONGITUDES DE ANCLAJE EN TRACCION - BARRAS INFERIORES - NORMA E-0,60
1). Ld >= 0,06Ab*fy / f'c^0,5
fy (kg/cm2)
4200
2), Ld >= 0,006db*fy
f'c (kg/cm2)
280
3), Ld >= 0,30m
Ld (cm)
BARRA (")
db (cm)
Ab (cm2)
1),
2),
5/8
1.59
1.98
29.81
40.01
3/4
1.91
2.85
42.92
48.01
1
2.54
5.07
76.31
64.01
1 1/4
3.18
7.92
119.23
80.01

LONGITUDES DE ANCLAJE EN TRACCION - BARRAS SUPERIORES - NORMA-E-0,60


1), L'd >= 1,4*Ld de barras inferiores
fy (kg/cm2)
4200
2), L'd >= 0,30m
f'c (kg/cm2)
280
Ld (cm)
BARRA (")
5/8
3/4
1
1 1/4

db (cm)
1.59
1.91
2.54
3.18

Ab (cm2)
1.98
2.85
5.07
7.92

1),
29.81
42.92
76.31
119.23

2),
40.01
48.01
64.01
80.01

ANCLAJE CON GANCHO ESTANDAR - NORMA E-0,60


1), Ldg >= 318*db / f'c^0,5
fy (kg/cm2)
2), Ldg >= 8db
f'c (kg/cm2)
3), Ldg >= 0,15m
Ldg (cm)
BARRA (")
db (cm)
Ab (cm2)
1),
2),
5/8
1.59
1.98
30.17
12.70
3/4
1.91
2.85
36.20
15.24
1
2.54
5.07
48.27
20.32
1 1/4
3.18
7.92
60.34
25.40

L'd (cm)
1),
56.01
67.21
106.83
166.93

4200
280

DISEO POR CORTE VP - PISO 2


f'c (kg/cm2)

280

fy (kg/m2)

DISEO PARA LAS SECCIONES DE CORTANTE MAXIMA Y MINIMA POSITIVA


TRAMO
A- B
B-C
C-D
WD (kg/m)
4435.5
4435.5
4435.5
4435.5
4435.5
4435.5
WL (kg/m)
1530
1530
1530
1530
1530
1530
CORTANTE 15408.149 23871.578 26479.447 23120.497
20566.85
19036.301
d (peralte)
54
54
54
54
54
54
b (base)
25
25
25
25
25
25
Vu (kg/cm2) 12186.779 20650.208 23258.077 19899.127 17345.480 15814.931
Vc (kg/cm2) 10176.714 10176.714 10176.714 10176.714 10176.714 10176.714
Vs (kg/cm2)
2364.782 12321.757 15389.839 11438.133
8433.842
6633.196
Av (cm2)
1.42
1.42
1.42
1.42
1.42
1.42
s (cm)
136.188
26.137
20.927
28.156
38.186
48.552
Vs lim
24848.803 24848.803 24848.803 24848.803 24848.803 24848.803
s max
27
27
27
27
27
27

Si Vc Vc , entonces se utilizara estribos mnimos, con un espaciamiento que no exceda del menor de los dos siguie
s max = Av*fy / 0,2*f'c*bw
s max = Av*fy / 3,5*bw

Av : area proporcionada por los estribos colocados

Si Vc 0,5*Vc , entonces no se necesita ningun refuerzo por corte, salvo los estribos de montaje.
Si Vc > Vc , es necesario refuerzo por corte.
Vs : Resistencia al corte suministrada por el acero

Vs = Vu/ - Vc
Vs 2,1*f'c*bw*d

Verificacion de la resistencia al corte del acero

Vs Vs lim
Vs lim = 1,1*f'c*bw*d

SI
Vs Vs lim

estribos mnimos
L'

Vs
Vu
Vc
Lo
estribos a s variable
Xo
cara del apoyo

s = Av * fy * d / Vs
Vs = Vu / - Vc
Vu = V - W*d

de montaje

Vu : Cortante de diseo
d : peralte de la viga
W : carga distribuida en la viga, hasta una distancia d.
V : fuerza cortante.
Vc = *(0,53*f'c)*bw*d
Vc : Resistencia al corte suministrada por el concreto
: factor de reduccion de resistencia al corte (0,85)
bw : base de la viga
TRAMO
CORTANTE
Lo (cm)
L' = L" (cm)
Xo (m)

A- B
B-C
C-D
15408.149 23871.578 26479.447 23120.497
20566.85
19036.301
33.695
175.568
219.284
162.977
120.170
94.514
85.296
85.296
85.296
85.296
85.296
85.296
2.583
4.002
4.439
3.876
3.448
3.191
ESPACIAMIENTO DE ESTRIBOS 3/8" EN Lo
s (cm)
27.000
26.137
20.927
27.000
27.000
27.000
13/8" @ s cm
5.000
5.000
5.000
5.000
5.000
5.000
n3/8" @ 18 cm
0
0
0
0
0
0
n3/8" @ 22 cm
0
0
5
0
0
0
n3/8" @ 25 cm
0
4
3
0
3
0
n3/8" @ 27 cm
1.000
2.000
1.000
5.000
1.000
3.000
verificaion
ok
ok
ok
ok
ok
ok
ZONA DE ESTRIBOS MINIMOS 3/8" EN L'
s max (cm)
68.16
68.16
68.16
68.16
68.16
68.16
resto 3/8" @ 30 cm

VP - PISO 2
fy (kg/cm2)

Pmin=14 / fy
As max = 0,75*Pb*b*d
As min = Pmin*b*d

4200

0.003333
29.2613
4.5000

AXIMO NEGATIVO Y POSITIVO


TRAMO C-D APOYO D TRAMO D-E APOYO E
21400.315
6422.345
13947.460
25185.510
13947.46
21400.315 25185.51
6422.345
25.000
25.000
25.000
25.000
54.000
54.000
54.000
54.000

*fy2 / 1,7*f'c*b)As2 - (*fy*d)As + Mu = 0


7.169
11.322
13.536
3.214
21"
21"
31"
25/8"+13/8"
10.140
10.140
15.210
4.670
7.158
7.158
10.736
3.296
19326.034 19326.034 27960.250
9241.448
0.016
0.016
0.010
0.039

En ningun caso el As calculado es


mayor al As max, por tanto no se
necesita acero en compresin

Donde s > y, para todos los tramos,


entonces se garantiza la fluencia en el
acero de refuerzo

Si s y, entoces se garantiza la fluencia del acero


Si s y, entoces el acero no fluira, falla a compresion
y = fy / Es = 0,0021

TRAMO C-D

APOYO D TRAMO D-E APOYO E


11.322
3.214
10.140
4.670
7.169
13.536
10.140
15.210
21400.315
6422.345
19326.034
9241.448
13947.46
25185.51
19326.034
27960.250

URIDAD
ios.

resulatdos del analisis, es la de momento positivo en


tra 18,480 necesario), en consecuencia el factor de
ficientes).
3.090

3.090
factor de seguridad global, hubiera sido.
1.741

d de 1,741 a 3,090, considerando aceptable para

NCLAJE

Ld : longitud de desarrollo
Ab : seccion de la barra de refuerzo longitudinal
Para las tres ecuaciones se toma el mayor valor

Ldg : longitud de desarrollo en gancho


db : diametro de la barra de refuerzo longitudinal
Se tomara el valor maximo de las tres ecuaciones

4200

MINIMA POSITIVA
D-E
3217.7
5480
1530
1530
21618.642 18892.452
54
54
25
25
19054.884 15107.052
10176.714 10176.714
10444.906
5800.397
1.42
1.42
30.834
55.523
24848.803 24848.803
27
27

no exceda del menor de los dos siguientes:

orcionada por los estribos colocados

tribos de montaje.

a al corte suministrada por el acero


la resistencia al corte del acero

s max = d/2

(0,60m)

s max = d/4

(0,30m)

de montaje
L"
0,5Vc

Para todos los casos Vu > Vc , se


necesita refuerzo por corte.
Como Vs < Vs lim , s max sera igual a
d / 2 o 60cm

D-E
21618.642 18892.452
186.999
70.333
107.175
72.587
4.553
2.695

Lo
27.000
5.000
0
0
4
3.000
ok

27.000
5.000
0
0
0
2.000
ok

68.16

68.16

L'

aso el As calculado es
s max, por tanto no se
acero en compresin

y, para todos los tramos,


garantiza la fluencia en el
ero de refuerzo

a compresion

DISEO POR FEXION VP - PISO 3


Calidad del concreto

f'c (kg/cm2)

Pb = 0,851*(f'c/fy)*6300 / (6300+fy)
As max = 0,75*Pb*b*d
Acero
positivo As min = Pmin*b*d

Mu neg (kg-m)
Mu pos (kg-m)
Mu / vigueta (kg-m)
Base "b" (cm)
Peralte "d" (cm)

280

Acero Grado 60

ACEROS MXIMOS Y MINIMOS


0.0289
29.2613
Acero
4.5000
negativo

Pmin=14 / fy
As max = 0,75*Pb*b*d
As min = Pmin*b*d

DISEO DE LAS SECCIONES DE MOMENTO MAXIMO NEGATIVO Y POSITIVO


APOYO A TRAMO A-B APOYO B TRAMO B-C APOYO C
6918.678
28949.556
26858.970
19648.503
29679.064
6918.678
19648.503 28949.556 29679.064 26858.97
25.000
25.000
25.000
25.000
25.000
54.000
54.000
54.000
54.000
54.000

El area de acero se calcula despejando la ecuacion: (*fy2 / 1,7*f'c*b)As2 - (*fy*d)As + Mu


As requerido (cm2)
3.468
10.322
15.818
16.270
14.540
21"
31"
31"
31"
25/8"+13/8"
As colocado (cm2)
4.670
10.140
15.210
15.210
15.210
aMn
= As*fy
/ 0,85*f'c*b- a/2)
(cm)
3.296
7.158
10.736
10.736
10.736
= *As*fy*(d
(kg-m)
9241.448 19326.034 27960.250 27960.250 27960.250
s = (1*d - a)*0,003 / a
0.039
0.016
0.010
0.010
0.010

As neg

As pos

As negativo
As positivo
Resistencias
negativas
Resistencias
positivas

necesario
colocado
necesario
colocado
exigidas
suministradas

exigidas
suministradas

APOYO A TRAMO A-B APOYO B TRAMO B-C APOYO C


3.468
15.818
14.540
4.670
15.210
15.210
10.322
16.270
10.140
15.210
6918.678
28949.556
26858.97
9241.448
27960.250
27960.250
19648.503
29679.064
19326.034
27960.250

ESTIMACION DEL FACTOR DE SEGURIDAD


Los aceros negativos y positivos colocados se aproximan lo suficiente a los necesarios.

Es claro que la seccion que gobierna la resistencia del aligerado, si se aceptan los resulatdos del analisis, es la de mome
en el apoyo D, donde se presenta el mayor defecto del acero (10,460 colocado contra 10,711 necesario), en consecuenci
seguridad de la viga frente a la falla por flexion sera (Metodo aproximado de los coeficientes).
Wu =
10588.497
(1/16)*Wu*(6,5)^2 =27960,250
F.S. =

(1/16)*Wu*(6,5)^2 =27960,250

F.S. =
Wservicio =
3807
Si se hubieran proporcionado areas de acero exactamente iguales a las exigidas, el factor de seguridad global, hubiera sid
Wu =
5965
F.S. =
Wservicio =
3807
El haber modificado el area de acero en el apoyo D, modifica el factor de seguridad de 1,741 a 3,090, considerando acep
efectos de calculo.

ADHERENCIA Y ANCLAJE
LONGITUDES DE ANCLAJE EN TRACCION - BARRAS INFERIORES - NORMA E-0,60
1). Ld >= 0,06Ab*fy / f'c^0,5
fy (kg/cm2)
4200
2), Ld >= 0,006db*fy
f'c (kg/cm2)
280
3), Ld >= 0,30m
Ld (cm)
BARRA (")
db (cm)
Ab (cm2)
1),
2),
1/4
0.64
0.32
4.77
16.00
3/8
0.95
0.71
10.73
24.00
5/8
1.59
1.98
29.81
40.01
3/4
1.91
2.85
42.92
48.01
1
2.54
5.07
76.31
64.01
1 1/4
3.18
7.92
119.23
80.01
LONGITUDES DE ANCLAJE EN TRACCION - BARRAS SUPERIORES - NORMA-E-0,60
1), L'd >= 1,4*Ld de barras inferiores
fy (kg/cm2)
4200
2), L'd >= 0,30m
f'c (kg/cm2)
280
Ld (cm)
BARRA (")
1/4
3/8
5/8
3/4
1
1 1/4

db (cm)
0.64
0.95
1.59
1.91
2.54
3.18

Ab (cm2)
0.32
0.71
1.98
2.85
5.07
7.92

1),
4.77
10.73
29.81
42.92
76.31
119.23

2),
16.00
24.00
40.01
48.01
64.01
80.01

ANCLAJE CON GANCHO ESTANDAR - NORMA E-0,60


1), Ldg >= 318*db / f'c^0,5
fy (kg/cm2)
2), Ldg >= 8db
f'c (kg/cm2)
3), Ldg >= 0,15m
Ldg (cm)
BARRA (")
db (cm)
Ab (cm2)
1),
2),
1/4
0.64
0.32
12.07
5.08
3/8
0.95
0.71
18.10
7.62
5/8
1.59
1.98
30.17
12.70
3/4
1.91
2.85
36.20
15.24
1
2.54
5.07
48.27
20.32
1 1/4
3.18
7.92
60.34
25.40

L'd (cm)
1),
22.40
33.60
56.01
67.21
106.83
166.93

4200
280

DISEO POR CORTE VP - PISO 3


f'c (kg/cm2)

280

fy (kg/m2)

DISEO PARA LAS SECCIONES DE CORTANTE MAXIMA Y MINIMA POSITIVA


TRAMO
A- B
B-C
C-D
WD (kg/m)
4435.5
4435.5
4435.5
4435.5
4435.5
4435.5
WL (kg/m)
1530
1530
1530
1530
1530
1530
CORTANTE 15225.236 15924.524 29092.516 23159.383 20589.641 18593.443
d (peralte)
54
54
54
54
54
54
b (base)
25
25
25
25
25
25
Vu (kg/cm2) 12003.866 12703.154 25871.146 19938.013 17368.271 15372.073
Vc (kg/cm2) 10176.714 10176.714 10176.714 10176.714 10176.714 10176.714
Vs (kg/cm2)
2149.590
2972.282 18464.037 11483.881
8460.655
6112.187
Av (cm2)
1.42
1.42
1.42
1.42
1.42
1.42
s (cm)
149.822
108.353
17.442
28.044
38.065
52.691
Vs lim
24848.803 24848.803 24848.803 24848.803 24848.803 24848.803
s max
27
27
27
27
27
27

Si Vc Vc , entonces se utilizara estribos mnimos, con un espaciamiento que no exceda del menor de los dos siguie
s max = Av*fy / 0,2*f'c*bw
s max = Av*fy / 3,5*bw

Av : area proporcionada por los estribos colocados

Si Vc 0,5*Vc , entonces no se necesita ningun refuerzo por corte, salvo los estribos de montaje.
Si Vc > Vc , es necesario refuerzo por corte.
Vs : Resistencia al corte suministrada por el acero

Vs = Vu/ - Vc
Vs 2,1*f'c*bw*d

Verificacion de la resistencia al corte del acero

Vs Vs lim
Vs lim = 1,1*f'c*bw*d

SI
Vs Vs lim

estribos mnimos
L'

Vs
Vu
Vc
Lo
estribos a s variable
Xo
cara del apoyo

s = Av * fy * d / Vs
Vs = Vu / - Vc
Vu = V - W*d

de montaje

Vu : Cortante de diseo
d : peralte de la viga
W : carga distribuida en la viga, hasta una distancia d.
V : fuerza cortante.
Vc = *(0,53*f'c)*bw*d
Vc : Resistencia al corte suministrada por el concreto
: factor de reduccion de resistencia al corte (0,85)
bw : base de la viga
TRAMO
CORTANTE
Lo (cm)
L' = L" (cm)
Xo (m)

A- B
B-C
C-D
15225.236 15924.524 29092.516 23159.383 20589.641 18593.443
30.629
42.351
263.087
163.629
120.552
87.090
85.296
85.296
85.296
85.296
85.296
85.296
2.552
2.669
4.877
3.882
3.451
3.117
ESPACIAMIENTO DE ESTRIBOS 3/8" EN Lo
s (cm)
27.000
27.000
17.442
27.000
27.000
27.000
13/8" @ s cm
5.000
5.000
5.000
5.000
5.000
5.000
n3/8" @ 18 cm
0
0
5
0
0
0
n3/8" @ 22 cm
0
0
4
0
0
0
n3/8" @ 25 cm
0
0
2
0
0
0
n3/8" @ 27 cm
0.000
1.000
1.000
5.000
4.000
3.000
verificaion
ok
ok
ok
ok
ok
ok
ZONA DE ESTRIBOS MINIMOS 3/8" EN L'
s max (cm)
68.16
68.16
68.16
68.16
68.16
68.16
resto 3/8" @ 30 cm

VP - PISO 3
fy (kg/cm2)

Pmin=14 / fy
As max = 0,75*Pb*b*d
As min = Pmin*b*d

4200

0.003333
29.2613
4.5000

AXIMO NEGATIVO Y POSITIVO


TRAMO C-D APOYO D TRAMO D-E APOYO E
20332.579
6194.633
12113.601
24934.664
12113.601 20332.579 24934.664 6194.633
25.000
25.000
25.000
25.000
54.000
54.000
54.000
54.000

*fy2 / 1,7*f'c*b)As2 - (*fy*d)As + Mu = 0


6.185
10.711
13.387
3.098
21"
21"
31"
25/8"+13/8"
10.140
10.140
15.210
4.670
7.158
7.158
10.736
3.296
19326.034 19326.034 27960.250
9241.448
0.016
0.016
0.010
0.039

En ningun caso el As calculado es


mayor al As max, por tanto no se
necesita acero en compresin

Donde s > y, para todos los tramos,


entonces se garantiza la fluencia en el
acero de refuerzo

Si s y, entoces se garantiza la fluencia del acero


Si s y, entoces el acero no fluira, falla a compresion
y = fy / Es = 0,0021

TRAMO C-D

APOYO D TRAMO D-E APOYO E


10.711
3.098
10.140
4.670
6.185
13.387
10.140
15.210
20332.579
6194.633
19326.034
9241.448
12113.601
24934.664
19326.034
27960.250

URIDAD
ios.

resulatdos del analisis, es la de momento negativo


ra 10,711 necesario), en consecuencia el factor de
ficientes).
3.090

3.090
factor de seguridad global, hubiera sido.
1.741

de 1,741 a 3,090, considerando aceptable para

NCLAJE

Ld : longitud de desarrollo
Ab : seccion de la barra de refuerzo longitudinal
Para las tres ecuaciones se toma el mayor valor

Ldg : longitud de desarrollo en gancho


db : diametro de la barra de refuerzo longitudinal
Se tomara el valor maximo de las tres ecuaciones

4200

MINIMA POSITIVA
D-E
3217.7
5480
1530
1530
21704.183 18798.124
54
54
25
25
19140.425 15012.724
10176.714 10176.714
10545.542
5689.423
1.42
1.42
30.540
56.606
24848.803 24848.803
27
27

no exceda del menor de los dos siguientes:

orcionada por los estribos colocados

tribos de montaje.

a al corte suministrada por el acero


la resistencia al corte del acero

s max = d/2

(0,60m)

s max = d/4

(0,30m)

de montaje
L"
0,5Vc

Para todos los casos Vu > Vc , se


necesita refuerzo por corte.
Como Vs < Vs lim , s max sera igual a
d / 2 o 60cm

D-E
21704.183 18798.124
188.801
68.987
107.175
72.587
4.572
2.682

Lo
27.000
5.000
0
0
0
6.000
ok

27.000
5.000
0
0
0
2.000
ok

68.16

68.16

L'

aso el As calculado es
s max, por tanto no se
acero en compresin

y, para todos los tramos,


garantiza la fluencia en el
ero de refuerzo

a compresion

DISEO POR FEXION VP - PISO 4


Calidad del concreto

f'c (kg/cm2)

Pb = 0,851*(f'c/fy)*6300 / (6300+fy)
As max = 0,75*Pb*b*d
Acero positivo
As min = Pmin*b*d

Mu neg (kg-m)
Mu pos (kg-m)
Mu / vigueta (kg-m)
Base "b" (cm)
Peralte "d" (cm)

280

Acero Grado 60

ACEROS MXIMOS Y MINIMOS


0.0289
29.2613
Acero
4.5000
negativo

Pmin=14 / fy
As max = 0,75*Pb*b*d
As min = Pmin*b*d

DISEO DE LAS SECCIONES DE MOMENTO MAXIMO NEGATIVO Y POSITIVO


APOYO A TRAMO A-B APOYO B TRAMO B-C
APOYO C
3199.986
17648.959
14098.961
13195.896
6551.765
3199.986
13195.896 17648.959
6551.765 14098.961
25.000
25.000
25.000
25.000
25.000
54.000
54.000
54.000
54.000
54.000

El area de acero se calcula despejando la ecuacion: (*fy2 / 1,7*f'c*b)As2 - (*fy*d)As +


As requerido (cm2)
1.584
6.764
9.200
3.280
7.251
21"
21"
23/4"+13/8"
25/8"+13/8" 23/4"+13/8"
As colocado (cm2)
4.670
6.410
10.140
6.410
10.140
a = As*fy / 0,85*f'c*b (cm)
3.296
4.525
7.158
4.525
7.158
Mn = *As*fy*(d - a/2) (kg-m)
9241.448 12535.928 19326.034
12535.928
19326.034
s = (1*d - a)*0,003 / a
0.039
0.027
0.016
0.027
0.016

As neg

As pos

As negativo
As positivo
Resistencias
negativas
Resistencias
positivas

necesario
colocado
necesario
colocado
exigidas
suministradas

exigidas
suministradas

APOYO A TRAMO A-B APOYO B TRAMO B-C


APOYO C
1.584
9.200
7.251
4.670
10.140
10.140
6.764
3.280
6.410
6.410
3199.986
17648.959
14098.961
9241.448
19326.034
19326.034
13195.896
6551.765
12535.928
12535.928

ESTIMACION DEL FACTOR DE SEGURIDAD


Los aceros negativos y positivos colocados se aproximan lo suficiente a los necesarios.

Es claro que la seccion que gobierna la resistencia del aligerado, si se aceptan los resulatdos del analisis, es la de mome
(A-B), donde se presenta el mayor defecto del acero (6,410 colocado contra 6,764 necesario), en consecuencia el factor d
frente a la falla por flexion sera (Metodo aproximado de los coeficientes).
Wu =
3263.792
(1/11)*Wu*(6,5)^2 =12535,928
F.S. =

(1/11)*Wu*(6,5)^2 =12535,928

F.S. =
Wservicio =
2570
Si se hubieran proporcionado areas de acero exactamente iguales a las exigidas, el factor de seguridad global, hubiera sid
Wu =
3982.5
F.S. =
Wservicio =
2570
El haber modificado el area de acero en el 2do apoyo, modifica el factor de seguridad de 1,722 a 1,411, considerando est
para efectos de calculo.

ADHERENCIA Y ANCLAJE
LONGITUDES DE ANCLAJE EN TRACCION - BARRAS INFERIORES - NORMA E-0,60
1). Ld >= 0,06Ab*fy / f'c^0,5
fy (kg/cm2)
4200
2), Ld >= 0,006db*fy
f'c (kg/cm2)
280
3), Ld >= 0,30m
Ld (cm)
BARRA (")
db (cm)
Ab (cm2)
1),
2),
3/8
0.95
0.71
10.73
24.00
5/8
1.59
1.98
29.81
40.01
3/4
1.91
2.85
42.92
48.01
1
2.54
5.07
76.31
64.01

LONGITUDES DE ANCLAJE EN TRACCION - BARRAS SUPERIORES - NORMA-E-0,60


1), L'd >= 1,4*Ld de barras inferiores
fy (kg/cm2)
4200
2), L'd >= 0,30m
f'c (kg/cm2)
280
Ld (cm)
BARRA (")
3/8
5/8
3/4
1

db (cm)
0.95
1.59
1.91
2.54

Ab (cm2)
0.71
1.98
2.85
5.07

1),
10.73
29.81
42.92
76.31

2),
24.00
40.01
48.01
64.01

ANCLAJE CON GANCHO ESTANDAR - NORMA E-0,60


1), Ldg >= 318*db / f'c^0,5
fy (kg/cm2)
2), Ldg >= 8db
f'c (kg/cm2)
3), Ldg >= 0,15m
Ldg (cm)
BARRA (")
db (cm)
Ab (cm2)
1),
2),
3/8
0.95
0.71
18.10
7.62
5/8
1.59
1.98
30.17
12.70
3/4
1.91
2.85
36.20
15.24
1
2.54
5.07
48.27
20.32

L'd (cm)
1),
33.60
56.01
67.21
106.83

4200
280

DISEO POR CORTE VP - PISO 4


f'c (kg/cm2)

280

fy (kg/m2)

TRAMO
WD (kg/m)
WL (kg/m)
CORTANTE
d (peralte)
b (base)
Vu (kg/cm2)
Vc (kg/cm2)
Vs (kg/cm2)
Av (cm2)
s (cm)
Vs lim
s max

DISEO PARA LAS SECCIONES DE CORTANTE MAXIMA Y MINIMA POSITIVA


A- B
B-C
C-D
3217.5
3217.5
3217.5
3217.5
3217.5
3217.5
765
765
765
765
765
765
10252.088 15924.524 13061.593 12824.657
12246.103
14045.184
54
54
54
54
54
54
25
25
25
25
25
25
8101.538 13773.974 10911.043 10674.107
10095.553
11894.634
10176.714 10176.714 10176.714 10176.714
10176.714
10176.714
Vu Vc
4232.070
863.916
585.168
Vu Vc
2021.082
1.42
1.42
1.42
1.42
1.42
1.42
s s max
76.099
372.786
550.365 s s max
159.348
24848.803 24848.803 24848.803 24848.803
24848.803
24848.803
68.16
27
27
27
68.16
27

Si 0,5Vc < Vu Vc , entonces se utilizara estribos mnimos, con un espaciamiento que no exceda del menor de los d
s max = Av*fy / 0,2*f'c*bw
s max = Av*fy / 3,5*bw

Av : area proporcionada por los estribos coloca

Si Vu 0,5*Vc , entonces no se necesita ningun refuerzo por corte, salvo los estribos de montaje.
Si Vu > Vc , es necesario refuerzo por corte.
Vs = Vu/ - Vc

Vs : Resistencia al corte suministrada por el ac

Vs 2,1*f'c*bw*d

Verificacion de la resistencia al corte del acero

Vs Vs lim
Vs lim = 1,1*f'c*bw*d

SI
Vs Vs lim

estribos mnimos
L'

Vs
Vu
Vc
Lo
estribos a s variable
Xo
cara del apoyo

s = Av * fy * d / Vs
Vs = Vu / - Vc
Vu = V - W*d

de montaje

Vu : Cortante de diseo
d : peralte de la viga
W : carga distribuida en la viga, hasta una distancia d.
V : fuerza cortante.
Vc = *(0,53*f'c)*bw*d
Vc : Resistencia al corte suministrada por el concreto
: factor de reduccion de resistencia al corte (0,85)
bw : base de la viga
TRAMO
CORTANTE
Lo (cm)
L' = L" (cm)
Xo (m)
s (cm)
13/8" @ s cm
n3/8" @ 18 cm
n3/8" @ 22 cm
n3/8" @ 25 cm
n3/8" @ 27 cm
verificaion
s max (cm)

A- B
B-C
C-D
10252.088 15924.524 13061.593 12824.657
12246.103
14045.184
90.327
18.439
12.489
43.137
127.768
127.768
127.768
127.768
3.999
3.280
3.220
3.527
ESPACIAMIENTO DE ESTRIBOS 3/8" EN Lo
68.160
27.000
27.000
27.000
68.160
27.000
5.000
5.000
5.000
5.000
5.000
5.000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.000
3.000
0.000
0.000
0.000
1.000
ok
ok
ok
ok
ok
ok
ZONA DE ESTRIBOS MINIMOS 3/8" EN L'
68.16
68.16
68.16
68.16
68.16
68.16
resto 3/8" @ 30 cm

VP - PISO 4
fy (kg/cm2)

min=14 / fy
max = 0,75*Pb*b*d
min = Pmin*b*d

4200

0.003333
29.2613
4.5000

MO NEGATIVO Y POSITIVO
TRAMO C-D APOYO D TRAMO D-E APOYO E
17202.398
2960.395
5523.821
11949.200
5523.821
17202.398 11949.2
2960.395
25.000
25.000
25.000
25.000
54.000
54.000
54.000
54.000
/ 1,7*f'c*b)As2 - (*fy*d)As + Mu = 0
2.756
8.951
6.097
1.464
21"
23/4"+13/8"
23/4"+13/8" 25/8"+13/8"
6.410
10.140
6.410
4.670
4.525
7.158
4.525
3.296
12535.928 19326.034 12535.928
9241.448
0.027
0.016
0.027
0.039

En ningun caso el As calculado es


mayor al As max, por tanto no se
necesita acero en compresin

Donde s > y, para todos los tramos,


entonces se garantiza la fluencia en el
acero de refuerzo

Si s y, entoces se garantiza la fluencia del acero


Si s y, entoces el acero no fluira, falla a compresion
y = fy / Es = 0,0021

TRAMO C-D

APOYO D TRAMO D-E APOYO E


8.951
1.464
10.140
4.670
2.756
6.097
6.410
6.410
17202.398
2960.395
19326.034
9241.448
5523.821
11949.2
12535.928
12535.928

AD

s del analisis, es la de momento positivo en el tramo


, en consecuencia el factor de seguridad de la viga
1.411

1.411
seguridad global, hubiera sido.
1.722

22 a 1,411, considerando esta reduccion aceptable

NCLAJE

Ld : longitud de desarrollo
Ab : seccion de la barra de refuerzo longitudinal
Para las tres ecuaciones se toma el mayor valor

Ldg : longitud de desarrollo en gancho


db : diametro de la barra de refuerzo longitudinal
Se tomara el valor maximo de las tres ecuaciones

4200

MA POSITIVA
D-E
3217.5
3217.5
765
765
15636.082
9755.797
54
54
25
25
13485.532
7605.247
10176.714 10176.714
3892.727 Vu Vc
1.42
1.42
82.733 s s max
24848.803 24848.803
27
68.16

o exceda del menor de los dos siguientes:

onada por los estribos colocados

l corte suministrada por el acero

esistencia al corte del acero

s max = d/2

(0,60m)

s max = d/4

(0,30m)

de montaje
L"
0,5Vc

En los tramos donde Vu < Vc , se


tomara como Vu diseo el mayor.
Como Vs < Vs lim , s max sera igual a
d / 2 o 60cm

D-E
15636.082
9755.797
83.084
127.768
3.926
27.000
5.000
0
0
0
2.000
ok

68.160
5.000
0
0
0
0.000
ok

68.16

68.16

aso el As calculado es
s max, por tanto no se
acero en compresin

y, para todos los tramos,


garantiza la fluencia en el
ero de refuerzo