Вы находитесь на странице: 1из 4

SAFETY MANAGERS LOG

PROJECT: 100 willoughby street, Brooklyn NY


SAFETY MANAGER:
WEATHER
AM: 72 Degrees: cloudy
PM:
85 Degrees: partlt sunny

DATE:

DAILY SAFETY ACTIVITIES


PERSON/ COMPANY
NOTIFIED

6/26/15

DATE
NOTIFIED

LOCATIONS

OBSERVATIONS AND/OR UNSAFE CONDITIONS

standpipe/ siamese

At the time of inspection observed that dry pressurized standpipe


system pressurized from the cellar to the 58 floor at 24 psi ( AM
Inspection)and 25 psi ( PM Inspection ) painted Red and all hose
connections capped, FDNY connections and manuel air release valve in
good condition on all three side of property,red light installed at all
FDNY connection, with FDNY reguired signage posted unless noted
below.

Hydrostatic test

All approved OP-98 Available on file for throughout the building.

N/A

street hydrant

At the time of inspection observed that all hydrant were free and
clear of obstruction.

N/A

stairs and Exits

At time of inspection observed Staircase E from cellar to 3rd


floorwith proper handrails,Stair D from cellar to ground floor with
proper handrails,Stair A from cellar to 58 Floor and Stair B from
cellar to 59 Floor with all Handrails are in place.

N/A

Standpipe valve

At time of inspection observed that Control valve secured were


needed on floors 7, 17, 27, 36, 46, and 56 stairs A and B.

N/A

Building fire extinguishers

Core hallways need fire extinguishers to be installed at 2


locations on all floor and set back.

N/A

Hot work operations

11 hot works permits were issued, At time of inspection observed


that proper fire watch protocol used.

N/A

1st Floor

At time of inspection observed that standpipe connection control


valve boxed into the wall with sheetrock and metal stud,
stanspipe unaccessable for fire Dept access.

AvalonBay super

30-39 FL

At time of inspection observed that fire extinguishers need to be


hung up in stair B.

AvalonBay

Note

At time of inspection observed no Plastic caps are missing on


sidewalk shed in Duffield st front of hotel.

AvalonBay/UBS

5/7/15

Duffield side,hotel

At time of inspection observed that there is a gap in between


bottom of sidewalk shed and top of fence,needed to cover with
chicken wire.

AvalonBay/UBS

5/7/15

Revision Date - 3/5/09

LOCATIONS

OBSERVATIONS AND/OR UNSAFE CONDITIONS

PERSON/ COMPANY
NOTIFIED

Vertical netting

At time of inspection observed Zero cables tight and nettings in


good condition, no holes, and no gaps.

N/A

Orientations

today 2 new employee start for prince.

N/A

street

At time of inspection observed that flagman in place Directing


pedestrian and vehicular traffic.

N/A

Shaft ways

At time of inspection observed that Shaft ways protected with a


standard guardrails throughout the building,unless noted.

N/A

Elevator in readiness

At time of inspection observed that all hoist in readiness and


working condition, mid-rise hoist access from cellar to 29 FL, and
high-rise hoist from ground fl to 58 fl.

N/A

Flammable/Combustible Gas
and Liquid Storage

At time of inspection observed the flammable and combustible


gas/liquid stored properly in their respective cages and metal
cabinets, and properly labeled. Unless noted

N/A

Personal Protective
Equipment/site

At the time of inspection, personal protective equipment gave


reminders, such as hardhats, gloves, and eye protection.

N/A

DATE
NOTIFIED

Standpipe test
standpipe trace

Site Perimeter

At time of inspection perimeter fence inspection, observed that


fence is in good condition.
NONE REPORTED/NONE OBSERVED
ACCIDENTS: NONE REPORTED/NONE OBSERVED

VIOLATIONS/STOP WORK
ORDERS:

N/A

SAFETY MEETING: NONE


INSPECTIONS: NONE

SIGNATURE OF SITE SAFETY MANAGER: _________________________________________

DATE:

06/26/15

Disclaimer: The report of the above items are not intended to indicate that other unsafe conditions do not exist nor is it intended to imply that other violations and/or hazards not obse
thereon are safe and under control at the time of this survey. The general contractors, construction managers or subcontractors are not in any way relieved of their complete responsibilit
with OSHA regulations for safety, health and security of their employees or work areas under their control.

Revision Date - 3/5/09

E Code

P Code

Revision Date - 3/5/09

C Code

DATE
CORRECTED

17

17

P Code

E Code

C Code

DATE
CORRECTED

unsafe conditions do not exist nor is it intended to imply that other violations and/or hazards not observed or reported
ors, construction managers or subcontractors are not in any way relieved of their complete responsibility for compliance
eas under their control.

Revision Date - 3/5/09