Product Catalogue

Intelligent PDUs

Benefits of
Intelligent PDUs
Reduce energy costs:

Identify high power consumption


equipment by using logs and port
monitoring
Find opportunities for consolidation
of underutilised equipment such as
near-idle servers

Spot and prevent potential


problems to ensure uptime:

Use alarms to quickly identify


problems and drive resolution sooner
Set alarm thresholds to spot
potential problems such as overloads
that could lead to power loss and
downtime

Use environmental monitoring to


identify overcooling situations where
temperatures could be increased for
energy cost reduction

Use logs to identify erratic power


consumption

Manage and optimise power


capacity:

Use environmental monitoring to


evaluate planned vs. actual
temperatures to identify areas with
insufficient cooling

Use real-time remote monitoring to


understand usage vs. capacity and
make informed decisions on
equipment additions and data centre
changes
Evaluate actual usage versus
design assumptions (using equipment
nameplate ratings) to understand true
power needs which may help increase
equipment densities

Efficiently control power functions


and resolve problems quickly:
Use individual outlet control to
remotely restart equipment or shut
down specific units
Use sequencing to safely start up
or shut down equipment and avoid
creating demand spikes

Intelligent PDUs
Siemons line of intelligent PDUs
provide valuable energy
consumption data while reliably
delivering power to critical IT
equipment. Each of our PDU
families deliver real-time power
information with varying degrees
of intelligent functionality ranging
from basic Metered units to
full-featured Managed PDUs providing multiple options based
on the level of data and control
requirements.

All of our network-capable intelligent


PDUs also have the capacity to
connect environmental sensors,
allowing temperature, airflow, and
humidity to be measured to further
troubleshoot and optimise data centre
efficiency.
PDU Families
Metered
Monitored
Smart
Switched
Managed

Siemons intelligent PDUs may be


used as stand-alone units, or they
can communicate with third-party
software through common open
networking protocols.

FUNCTION
Built-In Display for Local Use
Device-Level Monitoring
Remote Monitoring via Ethernet Port
Environmental Sensor Ports
Locking Outlets
Outlet-Level Monitoring
Outlet-Level Switching/Control

METERED

MONITORED

SMART

P
P

P
P
P
P

P
P
P
P
P
P

Configurations
Various plug inputs
Single and 3-phase voltages
Horizontal and zero-U vertical styles
3m (10 ft.) cords (other lengths available
on requests)
Test data included with each unit

SWITCHED

MANAGED

P
P
P
P
P

P
P
P
P
P
P
P

Metered PDUs
Metered PDUs provides local visual
monitoring capability through a
built-in LED meter that displays
real-time consumption data.
Metered PDUs are a cost-effective
alternative to monitored or switched
PDUs when remote monitoring is not
desired, while providing a more
intelligent alternative to basic PDUs.
Units have environmental monitoring
capabilities through two RJ12 ports
to support two separately purchased
sensors directly, or up to 16 sensors
connected via splitters

The 3 phase and 60A units measure


current (amps) that scrolls through
each phase
Single-phase PDUs measure power
by scrolling through power factor,
amps, volts and watts
Alarm conditions with high or low
thresholds with notifications via buzzer,
email, or SNMP trap

Remote monitoring is established


via an RJ45 port for network
connection. Data can be
downloaded in PDA, XML and
SNMP formats

The LCD display provides the ability


to view power data locally. The
display is customizable for data
type, unit of measure and unique
device naming

Monitored
and Smart PDUs
Monitored and Smart PDUs enable
remote monitoring of power
consumption.

Smart PDUs
Smart PDUs offer the highest level of
monitioring by providing outlet-level
data collection.
Units have environmental monitoring
capabilities through two RJ12 ports
to support two separately purchased
sensors directly, or up to 16 sensors
connected via splitters

Monitored PDUs
Monitored PDUs collect data at an
aggregate, device- level, generating a
smaller quantity of information to
simplify management.

Remote monitoring is established


via an RJ45 port for network
connection. Data can be downloaded
in PDA, XML and SNMP formats

The LCD display provides the


ability to view power data locally.
The display is customizable for
data type, unit of measure and
unique device naming

Switched and
Managed PDUs
In addition to power monitoring,
switched and managed PDUs
enable users to remotely control
individual receptacles by
allowing equipment to be
restarted or remotely shut down.
Switched PDUs
Switched PDUs combine total PDU
power monitoring with port-level
switching. They are the ideal
solution when port control is
needed but only aggregate
consumption data is desired.

Managed PDUs
Managed PDUs offer the highest
level of control and monitoring by
providing outlet-level monitoring
and outlet-level switching.

User definable URL for each outlet.


Units have environmental monitoring
capabilities through two RJ12 ports to
support two separately purchased
sensors directly, or up to 16 sensors
connected via splitters.
The LCD display provides the ability to
view power data locally. The display is
customizable for data type, unit of
measure and unique device naming.

Remote monitoring is established via


an RJ45 port for network connection.
Data can be downloaded in PDA, XML
and SNMP formats.

Intelligent PDU
Software Introduction
The Intelligent PDUs browser-based software
can be accessed through the use of the units
individual IP address.
This can be utilised remotely to access charts, logs,
and alarms and directly interface with the unit to
configure and define settings, including high or low
thresholds for notifications via buzzer, email, or
SNMP trap. Data can be downloaded in PDA, XML
and SNMP formats.

Scan Here to watch Siemons


full software introduction video
or visit: www.siemon.com/ipdu

Sequential start up
and shut down to
manage loads.

The browser-based
interface is used to
access charts, logs,
and alarms.

Sensors Page Delta Configuration.

Specifications
General
Safety Compliance
Emissions
Cord Length
Circuit breakers
Outlet Color Coding
Material
Finish
Warranty

CE (International PDUs only)


FCC Part 15 Class A
3m (10 ft.)
30A and higher units
On 3 phase units for load balancing
18 Gauge Steel
Black powder coat
3 Years

Environmental
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Operating Elevation
Storage Elevation

-10C to 40C (50 to 104F)


-25C to 65C (-13 to 149F)
5% to 95% (non-condensing)
5% to 95% (non-condensing)
0 to 2000m (0 to 6561ft)
0 to 15240m (0 to 50000ft)

Networking

(not applicable to metered units)

Networking Protocols

HTTP, HTTPS (SSL/TLS), SMTP, POP3, ICMP,


DHCP, TCP/IP, NTP, Telnet, Syslog
10 Mbit; half-duplex
HTML, SNMP, CSV/Plain Text, XML

Ethernet Link Speed


Data Formats

Accessories
A range of accessories have been
developed to support the
application of the Intelligent PDU
solution into varying
environments, each designed

7ENS-WKIT

Water Sensor Cable

7ENS-TEMP

Temperature Sensor

to measure specific sets of data


such as: humidity, presence of
water, temperature and variations
in airflow.

7ENS-WATER
Water Sensor

7ENS-TEMPHAF

Temp/ Airflow/ Humidity Sensor

Mounting
Vertical PDUs mount via tooless
button attachments and include a
mounting bracket for additional flexibility
Horizontal PDUs mount to standard
EIA 19 in. configurations

7ENA-SPLIT-5

Splitter RJ12 x 5 way