Вы находитесь на странице: 1из 4

JINAN HONGYUAN ELECTRIC CO., LTD.

First of all, thanks a lot for your choosing our power supply. Pleaser read the manual carefully
before useing it. Model of this product is HCX500-N.

500w Xenon Lamp Power Supply


Model:HCX500-N

. Main Features
1. It can display current and voltage timely,this is convenient for monitoring the current and
voltage.
2. Simple internal and external control conversion function is convenient for the convert of
power supply internal control and the external computer control.
3. The current can be ajusted optionally between 1-25A.In order to build-up of
luminance,suggesting the start current more than 15A.
4. High efficiency of the whole machine and improve the load over current protection,
overload protection, effectively increase the power supply reliability.
5. The integration design of constant current and trigger module , the output line connects the
xenon lamp directly , easy to use.

6.the standard of 2 U chassis, convenient installation.


II. Specification

Input

Input Voltage

AC220V or AC110Vto be specified when placing order

AC frequency

47440HZ

Cold Surge Current

60A(AC220V Input)

30A(AC110 Input)

Current Leakage

0.7MAAC220V Input

0.4MA(AC110V Input)

TEL/FAX: +86 531 88190006/88190005


EMAIL : sale@jnhyec.com
WEB: www.jnhyec.com/en or http://laser-power.en.alibaba.com
ADD: No.15 Lanxiang Road, Tianqiao Area, Jinan, China.

SKYPE : laserpwr

JINAN HONGYUAN ELECTRIC CO., LTD.

Output

Voltage Ripple and Noise

<100mV

Maximum Output Current

DC125A

Current Rioole and Noise

<100mV

Temperature drift

<100ppm/

(Boot up half an hour)


Stability

<0.1%

(Boot up half an hour)


Efficiency

88full load

Mean Time Between

50000H

Failure (MTBF)
Withstand Voltage

Input-Output, Input-Shell: AC1500V 10MA 60S; Ourput-Shell:DC100V 10mA 60s

Protection

Output over current protection, overload protection

Environment

Operating Temperature-10~40
Relative Humidity (RH)90

Cooling Way

Force-Air Cooling (FAC)

Dimension

LWH=48219288 (mm)

Color

Black

III.Power Supply External Interface


1.Front Panel Controls and Displays
CURRENT

ON/OFF

VOLTAGE

POWER

RUN

ALARM

TEL/FAX: +86 531 88190006/88190005


EMAIL : sale@jnhyec.com
WEB: www.jnhyec.com/en or http://laser-power.en.alibaba.com
ADD: No.15 Lanxiang Road, Tianqiao Area, Jinan, China.

ON/OFF

INT/EXT CURRENT ADJ.

SKYPE : laserpwr

JINAN HONGYUAN ELECTRIC CO., LTD.


2Back Wiring and Interface
OUTPUT POSITIVE POLE

OUTPUT
NEGATIVE
POLE

EXT
CONTROL

EXT

FAN

FAN

AC INPUT

PROTECT

(DB9)

3External Interface Definition


ON/OFF--Power supply Start/Stop Control Inputinput high voltage5~12Vstart
low voltage (0.7V below)stop;
I/VOutput current, analog voltage output 25A corresponding 4V
V/IOutput current voltage control input5V corresponding 25A
GND--Output ground
GND--Output ground
WP--External protection alarmconnect luminous diode;
ALARM--Power and alarm LED,connect luminous diode
RUN-Power start-up instructionsconnect luminous diode
5V--Power Output

TEL/FAX: +86 531 88190006/88190005


EMAIL : sale@jnhyec.com
WEB: www.jnhyec.com/en or http://laser-power.en.alibaba.com
ADD: No.15 Lanxiang Road, Tianqiao Area, Jinan, China.

SKYPE : laserpwr

JINAN HONGYUAN ELECTRIC CO., LTD.


4. External interface diagram

IV. Notes
1, Pls pay more attention on the positive and negative output.The xenon lamp positive pole
and negative pole shold corresponding to the power supply positive pole and negative pole
(with a red marker is positive, black mark is cathode).In order to avoid damage the xenon
lamp,pls dont reverse connection.
2, If the xenon lamp extinguished Pls wait 3 minutes to restart it, so as not to damage the
xenon lamp electrodes.
3, The vents and fans of xenon lamp power supply should not be closed over.
4, If the xenon lamp power supply is placed in another case, pls make sure the air which
inside and ourside case convection, so as to have heat dissipation effect, otherwise the inside
case will be overheating, this will damage the xenon lamp power supply.
5, the power supplys earth external control interface and xenon lamps each wire is the
same,.Pls use isolation measures when using external interface control. The isolated power
supply on the side of the xenson lamp power supply should use xenon lamp power supply
itself 5 v power supply, avoiding interference.