Академический Документы
Профессиональный Документы
Культура Документы
Day
First
Day
(Gener
al)
Time
08.00
08.30
08.30
08.40
08.40
09.00
09.00
09.45
09.45
10.30
10.30
11.15
Activity/Sub
ject
Registration
National
Anthem
Opening
Remarks
Standardizati
on Policy
The
important
Interconnecte
d SNI
8153:2015
with other
International
standard of
UPC 2012
Plumbing in
Indonesia
Objectives
Short Description
Tools
Why standardization
needed
Benefit standardization
InFocus
BSN
Important deployment
of international
standard
Beneficial of
interconnected
standard
InFocus,
Video, Film
Experiences
of IAPMO
IAPMO
Reference
- Experiences
of Sofyan
Moh. Nur
Bambang as
expertise
- Plumbing
hand book
made by
Moh. Nur
Bambang
Instructor
Sofyan Nur
Bambang
Day
First
Day
(Techni
cal
Aspect
)
11.15
12.00
Introduction
of SNI
8153:2015
Plumbing
systems in
Building
12.00
13.00
Coffee Break
and Lunch
Time
Time
13.00
14.30
Activity/Sub
ject
Plumbing
Systems
Requirement
14.30
16.00
Water Supply
systems
16.00
16.15
16.15
Coffee Break
Water Supply
- InFocus,
Video,
Film
- SNI
8153:2015
- UPC 2012
Sudradjat
Committee
Objectives
Trainers are able to know
the
plumbing
system
requirement
and use
table 2
Trainers are able to know
and use the water supply
fixtures
units,
determine
pipe and
water meter
size,
flushometer
Short Description
Tools
Reference
Instructor
- SNI
- Sridarwati
8153:2015 - Person of IAPMO
- UPC 2012
(related table
422.1 of UPC
2012)
Application Table 3 of
SNI 8153:2015
Application Table 4 of
SNI 8153:2015
Application Table 5 of
SNI 8153:2015
- SNI
8153:2015
- UPC 2012
- InFocus,
Video,
Film
- Nurhasanah
- Person of IAPMO
(related table
610.4 of UPC
2012)
Committee
Trainers are - Application and
- InFocus,
- SNI
- Atang Sarbini
17.45
systems
able to know
and use the
water supply
fixtures
units,
determine
pipe.
Exercise Annex C 1 of
SNI 8153:2015
Video,
Film
8153:2015
- UPC 2012
- Person of IAPMO
(related Annex
Day
Second
Day
(Techni
cal
Aspect
)
Time
08.00
09.30
Activity/Su
bject
Wastewater/
Sanitary
drainage
systems
Objectives
Short Description
Tools
Reference
09.30
09.45
09.45
11.15
Coffee Break
Wastewater/
Sanitary
drainage
systems
- InFocus, - SNI
Video,
8153:2015
- UPC 2012
Film
11.15
12.00
Drainage
systems/
Storm
Drainage
- InFocus, - SNI
Video,
8153:2015
- UPC 2012
Film
12.00
13.00
Coffee Break
and Lunch
Time
Drainage
systems/
13.00
13.45
Instructor
- Atang Sarbini
- Person of
IAPMO
(related table
702.1 and
703.2 of UPC
2012)
Committee
- Tohir
- Person of
IAPMO
(related
figure
703.2A and
figure
703.2B of
UPC 2012)
- Sarbidi
- Person of
IAPMO
(related
table 1101.7,
1101.11,
1106.3 of
UPC 2012)
Committee
- InFocus, - SNI
Video,
8153:2015
- Sarbidi
- Person of
Storm
Drainage
13.45
14.30
14.30
table and
calculate the
sizing of
horizontal piping,
roof drains,
leaders, vertical
piping and
gutters
Film
- UPC 2012
IAPMO
(related
table 1101.7,
1101.11,
1106.3 of
UPC 2012)
Evaluation
Committee
Closing
Committee