Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
Customer:
Approved by:
Note:
1 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
- CONTENTS REVISION HISTORY
-------------------------------------------------------
1. GENERAL DESCRIPTION
-------------------------------------------------------
-------------------------------------------------------
-------------------------------------------------------
-------------------------------------------------------
11
-------------------------------------------------------
12
-------------------------------------------------------
15
-------------------------------------------------------
17
8. DEFINITION OF LABELS
-------------------------------------------------------
20
9. PRECAUTIONS
-------------------------------------------------------
21
1.1 OVERVIEW
1.2 FEATURES
1.3 APPLICATION
1.4 GENERAL SPECIFICATIONS
1.5 MECHANICAL SPECIFICATIONS
3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD MODULE
3.2 BACKLIGHT UNIT
4. BLOCK DIAGRAM
4.1 TFT LCD MODULE
4.2 BACKLIGHT UNIT
6. INTERFACE TIMING
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
6.2 POWER ON/OFF SEQUENCE
7. OPTICAL CHARACTERISTICS
7.1 TEST CONDITIONS
7.2 OPTICAL SPECIFICATIONS
2 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
REVISION HISTORY
Version
Date
Section
Ver 2.0
Aug. 30, 06
All
Description
M201P1-L03 Specifications was first issued.
3 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
1. GENERAL DESCRIPTION
1.1 OVERVIEW
M201P1-L03 is an 20.1 TFT Liquid Crystal Display module with 4 CCFL Backlight unit and 30 pins
2ch-LVDS interface. This module supports 1400 x 1050 SXGA+ mode and can display 16.7M colors. The
inverter module for Backlight is not built in.
1.2 FEATURES
- Wide viewing angle.
- High contrast ratio
- Super fast response time
- SXGA+ (1400 x 1050 pixels) resolution
- DE (Data Enable) only mode
- LVDS (Low Voltage Differential Signaling) interface
- RoHS Compliance
1.3 APPLICATION
- TFT LCD Monitor
Specification
408.24 (H) x 306.18 (V) (20.1 diagonal)
413.0(H) x 311.0(V)
a-si TFT active matrix
1400 x R.G.B. x 1050
0.2916 (H) x 0.2916 (V)
RGB vertical stripe
16.7M
Normally White
Anti - glare , Haze 25 , 3H
Unit
mm
mm
pixel
mm
color
-
Note
Unit
mm
mm
mm
g
Note
(1)
-
Min.
431.5
331
16.0
-
Typ.
432.0
331.5
16.5
-
Max.
432.5
332
17.0
2900
(1)
-
Note (1) Please refer to the attached drawings for more information of front and back outline dimensions.
4 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item
Value
Symbol
Storage Temperature
Operating Ambient Temperature
Shock (Non-Operating)
Vibration (Non-Operating)
Min.
-20
0
-
TST
TOP
SNOP
VNOP
Max.
60
50
50
1.5
Unit
Note
C
C
G
G
(1)
(1), (2)
(3), (5)
(4), (5)
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta 40 C).
(b) Wet-bulb temperature should be 39 C Max. (Ta > 40 C).
(c) No condensation.
Note (2) The temperature of panel display surface area should be 0 C Min. and 60 C Max.
60
Operating Range
40
20
10
-40
-20
Storage Range
0
20
40
60
80
Temperature (C)
LCD Module
Bracket
5 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
2.2 ELECTRICAL ABSOLUTE RATINGS
2.2.1 TFT LCD MODULE
Item
Power Supply Voltage
Logic Input Voltage
Symbol
Vcc
VIN
Value
Min.
-0.3
-0.3
Unit
Note
V
V
(1)
Unit
Note
VRMS
mARMS
KHz
(1), (2)
Max.
+6.0
4.3
Symbol
VL
IL
FL
Value
Min.
Max.
2.5K
7.5
80
2.0
45
(1), (2)
Note (1) Permanent damage to the device may occur if maximum values are exceeded. Function operation
should be restricted to the conditions described under Normal Operating Conditions.
Note (2) Specified values are for lamp (Refer to 3.2 for further information).
6 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD MODULE
Ta = 25 2 C
Parameter
Symbol
Vcc
VRP
IRUSH
White
Black
Power Supply Current
fV = 75Hz,
Vcc=4.5V
LVDS differential input voltage
LVDS common input voltage
Logic L input voltage
lcc
Vid
Vic
Vil
Min.
4.5
-
Value
Typ.
5.0
390
800
Max.
5.5
100
3.8
550
1100
-100
-
1.2
-
Unit
Note
V
mV
A
mA
mA
(2)
(3)a
(3)b
1500
mA
(4)
+100
0.8
mV
V
V
Note (1) The module is recommended to operate within specification ranges listed above for normal
function.
Note (2) Measurement Conditions:
+5.0V
Q1
2SK1475
Vcc
C3
FUSE
R1
47K
(High to Low)
(Control Signal)
Q2
R2
2SK1470
SW
1K
+12V
VR1
47K
C2
C1
0.01uF
1uF
GND
470s
7 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
Note (3) The specified power supply current is under the conditions at Vcc = 5.0 V, Ta = 25 2 C, fv = 60
Hz, whereas a power dissipation check pattern below is displayed.
b. Black Pattern
a. White Pattern
Active Area
Active Area
Note (4) The specified power supply current is under the conditions at Vcc = 4.5 V, Ta = 25 2 C, fv = 75
Hz, whereas a power dissipation check pattern (Black Pattern) below is displayed.
Black Pattern
Active Area
8 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
3.2 BACKLIGHT UNIT
Parameter
Ta = 25 2 C
Symbol
VL
IL
VS
Operating Frequency
Lamp Life Time
Power Consumption
FL
LBL
PL
Value
Typ.
775
7.0
----21.73
Min.
697
2.0
--45
40000
--
Max.
835
7.5
1500(25)
1710(0)
80
---
Unit
Note
VRMS
mARMS
VRMS
VRMS
KHz
Hrs
W
Note (1) Lamp current is measured by utilizing high frequency current meters as shown below:
HV (Pink)
LV (White)
LCD
Module
1
2
Inverter
HV (Blue)
LV (Black)
1
2
A
Current Meter
YOKOGAWA 2016
Note (2) The voltage that must be larger than Vs should be applied to the lamp for more than 1 second
after startup. Otherwise the lamp may not be turned on.
Note (3) The lamp frequency may produce interference with horizontal synchronous frequency from the
display, and this may cause line flow on the display. In order to avoid interference, the lamp
frequency should be detached from the horizontal synchronous frequency and its harmonics as far
as possible.
Note (4) PL = IL VL 4 CCFLs
Note (5) The lifetime of lamp can be defined as the time in which it continues to operate under the condition
Ta = 25 2 oC and IL = 7.0 mArms until one of the following events occurs:
(a) When the brightness becomes or lower than 50% of its original value.
(b) When the effective ignition length becomes or lower than 80% of its original value. (Effective
ignition length is defined as an area that has less than 70% brightness compared to the
brightness in the center point.)
Note (6) The waveform of the voltage output of inverter must be area-symmetric and the design of the
inverter must have specifications for the modularized lamp. The performance of the Backlight,
such as lifetime or brightness, is greatly influenced by the characteristics of the DC-AC inverter for
the lamp. All the parameters of an inverter should be carefully designed to avoid producing too
much current leakage from high voltage output of the inverter. When designing or ordering the
inverter please make sure that a poor lighting caused by the mismatch of the Backlight and the
inverter (miss-lighting, flicker, etc.) never occurs. If the above situation is confirmed, the module
should be operated in the same manners when it is installed in your instrument.
9 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
The output of the inverter must have symmetrical (negative and positive) voltage waveform and
symmetrical current waveform.( Asymmetrical ratio is less than 10%) Please do not use the inverter
which has asymmetrical voltage and asymmetrical current and spike wave. Lamp frequency may
produce interface with horizontal synchronous frequency and as a result this may cause beat on the
display. Therefore lamp frequency shall be as away possible from the horizontal synchronous
frequency and from its harmonics in order to prevent interference.
Requirements for a system inverter design, which is intended to have a better display performance, a
better power efficiency and a more reliable lamp. It shall help increase the lamp lifetime and reduce its
leakage current.
a. The asymmetry rate of the inverter waveform should be 10% below;
b. The distortion rate of the waveform should be within 2 10%;
c. The ideal sine wave form shall be symmetric in positive and negative polarities.
* Asymmetry rate:
Ip
| I p I p | / Irms * 100%
I -p
* Distortion rate
I p (or I p) / Irms
10 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
4. BLOCK DIAGRAM
4.1 TFT LCD MODULE
RXO0(+/-)
RXO3(+/-)
RXOC(+/-)
RXE0(+/-)
RXE1(+/-)
RXE2(+/-)
RXE3(+/-)
RXEC(+/-)
NC
Vcc
LVDS INPUT /
TIMING CONTROLLER
SCAN DRIVER IC
RXO2(+/-)
INPUT CONNECTOR
(STARCONN-093G0-B0001A)
RXO1(+/-)
DATA DRIVER IC
DC/DC CONVERTER &
REFERENCE VOLTAGE
GND
VL
LAMP CONNECTOR
(YEONHO-35001HS-02L)
BACKLIGHT UNIT
1 HV(Pink)
2 LV(White)
1 HV(Blue)
2 LV(Black)
1 HV(Pink)
2 LV(White)
1 HV(Blue)
2 LV(Black)
11 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
5. INPUT TERMINAL PIN ASSIGNMENT
5.1 TFT LCD MODULE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
RXO0RXO0+
RXO1RXO1+
RXO2RXO2+
GND
RXOCRXOC+
RXO3RXO3+
RXE0RXE0+
GND
RXE1RXE1+
GND
RXE2RXE2+
RXECRXEC+
RXE3RXE3+
GND
NC
NC
NC
VCC
VCC
VCC
12 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
LVDS interface receiver required input data mapping table
LVDS output
D7
D6
LVDS Channel E0
Data order
EG0
ER5
LVDS output
D18
D15
LVDS Channel E1
Data order
EB1
EB0
LVDS output
D26
D25
LVDS Channel E2
Data order
DE
NA
LVDS output
D23
D17
LVDS Channel E3
Data order
NA
EB7
LVDS output
D7
D6
LVDS Channel O0
Data order
OG0
OR5
LVDS output
D18
D15
LVDS Channel O1
Data order
OB1
OB0
LVDS output
D26
D25
LVDS Channel O2
Data order
DE
NA
LVDS output
D23
D17
LVDS Channel O3
Data order
NA
OB7
D4
ER4
D14
EG5
D24
NA
D16
EB6
D4
OR4
D14
OG5
D24
NA
D16
OB6
D3
ER3
D13
EG4
D22
EB5
D11
EG7
D3
OR3
D13
OG4
D22
OB5
D11
OG7
D2
ER2
D12
EG3
D21
EB4
D10
EG6
D2
OR2
D12
OG3
D21
OB4
D10
OG6
D1
ER1
D9
EG2
D20
EB3
D5
ER7
D1
OR1
D9
OG2
D20
OB3
D5
OR7
D0
ER0
D8
EG1
D19
EB2
D27
ER6
D0
OR0
D8
OG1
D19
OB2
D27
OR6
13 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
5.2 BACKLIGHT UNIT
Pin
1
2
Symbol
HV
LV
Description
High Voltage
Low Voltage
Remark
Pink
White
1
2
HV
LV
High Voltage
Low Voltage
Blue
Black
Data Signal
Green
Red
Blue
R7 R6 R5 R4 R3 R2 R1 R0 R7 R6 G5 G4 G3 G2 G1 G0 R7 R6 B5 B4 B3 B2 B1 B0
Black
Red
Green
Basic Blue
Colors Cyan
Magenta
Yellow
White
Red(0) / Dark
Red(1)
Red(2)
Gray
:
Scale
:
Of
Red(253)
Red
Red(254)
Red(255)
0
1
0
0
0
1
1
1
0
0
0
:
:
1
1
1
0
1
0
0
0
1
1
1
0
0
0
:
:
1
1
1
0
1
0
0
0
1
1
1
0
0
0
:
:
1
1
1
0
1
0
0
0
1
1
1
0
0
0
:
:
1
1
1
0
1
0
0
0
1
1
1
0
0
0
:
:
1
1
1
0
1
0
0
0
1
1
1
0
0
0
:
:
1
1
1
0
1
0
0
0
1
1
1
0
0
1
:
:
0
1
1
0
1
0
0
0
1
1
1
0
1
0
:
:
1
0
1
0
0
1
0
1
0
1
1
0
0
0
:
:
0
0
0
0
0
1
0
1
0
1
1
0
0
0
:
:
0
0
0
0
0
1
0
1
0
1
1
0
0
0
:
:
0
0
0
0
0
1
0
1
0
1
1
0
0
0
:
:
0
0
0
0
0
1
0
1
0
1
1
0
0
0
:
:
0
0
0
0
0
1
0
1
0
1
1
0
0
0
:
:
0
0
0
0
0
1
0
1
0
1
1
0
0
0
:
:
0
0
0
0
0
1
0
1
0
1
1
0
0
0
:
:
0
0
0
0
0
0
1
1
1
0
1
0
0
0
:
:
0
0
0
0
0
0
1
1
1
0
1
0
0
0
:
:
0
0
0
0
0
0
1
1
1
0
1
0
0
0
:
:
0
0
0
0
0
0
1
1
1
0
1
0
0
0
:
:
0
0
0
0
0
0
1
1
1
0
1
0
0
0
:
:
0
0
0
0
0
0
1
1
1
0
1
0
0
0
:
:
0
0
0
0
0
0
1
1
1
0
1
0
0
0
:
:
0
0
0
0
0
0
1
1
1
0
1
0
0
0
:
:
0
0
0
Green(0) / Dark
Green(1)
Green(2)
Gray
:
Scale
:
Of
Green(253)
Green
Green(254)
Green(255)
Blue(0) / Dark
Blue(1)
Blue(2)
Gray
:
Scale
:
Of
Blue(253)
Blue
Blue(254)
Blue(255)
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
1
:
:
0
1
1
0
0
0
:
:
0
0
0
0
1
0
:
:
1
0
1
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
0
0
0
0
0
1
:
:
0
1
1
0
0
0
:
:
0
0
0
0
1
0
:
:
1
0
1
14 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
6. INTERFACE TIMING
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
The input signal timing specifications are shown as the following table and timing diagram.
Signal
LVDS Clock
LVDS Data
Item
Frequency
Period
High Time
Low Time
Setup Time
Hold Time
Frame Rate
Total
Display
Blank
Total
Display
Blank
Symbol
Min.
Fc
Tc
14.8
Tch
Tcl
Tlvs
600
Tlvh
600
Fr
56
Tv
1051
Tvd
1050
Tvb
Tv-Tvd
Th
740
Thd
700
Thb
Th-Thd
Typ.
54
18.5
4/7
3/7
60
1066
1050
42
844
700
144
Max.
67.5
75
1300
1050
Tv-Tvd
980
700
Th-Thd
Unit
Note
MHz
ns
Tc
Tc
ps
ps
Hz Tv=Tvd+Tvb
Th
Th
Th
Tc
Th=Thd+Thb
Tc
Tc
-
Because this module is operated by DE only mode, Hsync and Vsync input signals should be set
to low logic level or ground. Otherwise, this module would operate abnormally.
Tv
TVb
TVd
DE
Th
DCLK
TC
Thd
Thb
DE
DATA
15 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
6.2 POWER ON/OFF SEQUENCE
To prevent a latch-up or DC operation of LCD module, the power on/off sequence should be as the
diagram below.
Power Supply
0.9 VCC
VCC
0.9 VCC
0.1VDD
0.1VCC
0V
0.5 msT110ms
0T250ms
T1
T3
0T350ms
500msT4
T4
VALID
Signals
0V
Power Off
Power On
Backlight (Recommended)
450 msT5
50%
50%
90msT6
T5
T6
16 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
7. OPTICAL CHARACTERISTICS
7.1 TEST CONDITIONS
Item
Ambient Temperature
Ambient Humidity
Supply Voltage
Input Signal
Lamp Current
Inverter Operating Frequency
Inverter
Symbol
Value
Unit
o
252
Ta
C
5010
Ha
%RH
Vcc
5
V
According to typical value in "3. ELECTRICAL CHARACTERISTICS"
IL
7.0
mA
FL
61
KHz
Sumida H05 5307
Color
Chromaticity
Green
Blue
White
Symbol
Rx
Condition
Min.
By
Wx
Wy
Max.
Unit
Note
0.640
Ry
Gx
Gy
Bx
Typ.
0.335
x=0, Y =0
CS-1000T
Typ
0.03
0.289
0.597
0.154
Typ +
0.03
(1), (5)
0.081
0.313
0.329
cd/m2 (4), (5)
LC
230
300
---
Contrast Ratio
CR
700
1000
---
------75
75
70
70
1.3
3.7
1.25
85
85
80
80
6.3
8.7
1.40
---------
ms
ms
-
(5), (6)
Deg.
(1), (5)
---
---
1.7
---
(7)
0.8
---
---
---
(8)
---
---
0.025
---
(7)(9)
TR
x=0, Y =0
TF
White Variation
W
x=0, Y =0
x+
Horizontal
xCR 10
Viewing Angle
Y+
Vertical
YLuminance uniformity
Angular dependence
CS-1000T
Luminance contrast
R=G=B=255
Safety
Angular dependence Grayscale
R=G=B= 0 Grayscale
Color uniformity
Angular dependence
Response Time
(2), (5)
(3)
17 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
Note (1) Definition of Viewing Angle (x, y):
Normal
x = y = 0
yX- = 90
y+
12 oclock direction
xx
6 oclock
y+
y+ = 90
x+
y-
x+
y- = 90
X+ = 90
100%
90%
Optical
Response
Gray Level 0
10%
0%
Time
TR
TF
66.67ms
66.67ms
18 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
Note (4) Definition of Luminance of White (LC):
Measure the luminance of gray level 255 at center point
LC = L (7)
L (x) is corresponding to the luminance of the point X at Figure in Note (6).
Note (5) Measurement Setup:
The LCD module should be stabilized at given temperature for 20 minutes to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 20 minutes in a windless room.
LCD Module
LCD Panel
Center of the Screen
BM-5A
CA-1000T
Field of View = 2
Light Shield Room
500 mm
Vertical Line
H o riz o n ta l L in e
: Test Point
X=1 to 13
A c tiv e A re a
19 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
Note (7) Definition of Luminance Uniformity Angular dependent
D/10
D/2
W/10
W/2
9W/10
9D/10
B
Active Area
Luminance is measured at the center measurement position C on the LCD panel. The optical
axis of meter shall be aligned with the normal of the panel surface. The measuring distance
between the meter and the surface of the panel is defined as:
Md (cm) = diagonal of the panel (cm) X 1.5
a. Horizontal - mode
+30
LCD panel
Lmax, +30
BM5A
C
Md
CS-1000T
Lmin, +30
The LCD panel is then rotated to another azimuthal angle to -30; and Lmin, -30 and Lmax, -30
are obtained by using the same procedure.
20 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
b. Vertical - mode
+15
Lmin, +15
BM5A
Md
CS-1000T
LCD panel
Lmax, +15
The LCD panel is then rotated to another azimuthal angle to -15; and Lmin, -15 and Lmax, -15
are obtained by using the same procedure.
The Luminance Uniformity is calculated as follow:
Lmax, +15/ Lmin, +15
Lmax, -15/ Lmin, -15
The largest value shall be reported.
D/10
D/2
W/10
W/2
9W/10
9D/10
B
Active Area
Luminance contrast is measured at the center point of the LCD panel C along with the normal
of the display with the same distance described in Note 7. The display is then rotated around the
vertical axis by changing its azimuthal axis to +30; and this gives:
21 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
L255 G.L., +30 and L0 G.L., +30.
30
LCD panel
BM-5A
The LCD panel is then rotated to azimuthal angle to -30; and L0 G. L., -30 and L63 G.L., -30 are
obtained by using the same procedure. The Luminance Contrast is calculated:
Measuring point L
u'L
v'L
u'v'
+30
-30
u 'v'=
(u ' R u ' L )2
+ (v ' R v ' L
)2
For both +30 and -30. The largest value in u'v' shall be reported.
22 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
8. DEFINITION OF LABELS
8.1 CMO MODULE LABEL
The barcode nameplate is pasted on each module as illustration, and its definitions are as following explanation.
Meaning
CMO internal use
Revision
CMO internal use
Year, month, day
YMD
L
NNNN
Product line #
Serial number
Description
Cover all the change
Year: 2001=1, 2002=2, 2003=3, 2004=4
Month: 1~12=1, 2, 3, ~, 9, A, B, C
Day: 1~31=1, 2, 3, ~, 9, A, B, C, ~, W, X, Y, exclude I, O, and U.
Line 1=1, Line 2=2, Line 3=3,
Manufacturing sequence of product
Meaning
Supplier code
Model number
Revision code
XX
L
XX
L
Cell location
Cell line #
Module location
Module line #
Year, month, day
YMD
NNNN
Serial number
Description
CMO=CM
M201P1-L03=20P13
Non ZBD: 0~9, ZBD: A~Z
Century=1, CLL=2, Demos=3, Epson=4, Fujitsu=5, Himax=6,
Hitachi=7, Hynix=8, LDI=9, Matsushita=A, NEC=B, Novatec=C,
OKI=D, Philips=E, Renasas=F, Samsung=G, Sanyo=H, Sharp=I,
TI=J, Topro=K, Toshiba=L, Windbond=M
Tainan, Taiwan=TN
1~12=0~C
Tainan, Taiwan=TN
1~12=0~C
Year: 2001=1, 2002=2, 2003=3, 2004=4
Month: 1~12=1, 2, 3, ~, 9, A, B, C
Day: 1~31=1, 2, 3, ~, 9, A, B, C, ~, T, U, V
By LCD supplier
23 / 26
Version 2.0
DOC No.:
Issued Date: Aug. 30, 2006
Model No.: M201P1-L03
Approval
9. PRECAUTIONS
9.1 ASSEMBLY AND HANDLING PRECAUTIONS
(1) Do not apply rough force such as bending or twisting to the module during assembly.
(2) To assemble or install module into users system can be only in clean working areas. The dust and oil
may cause electrical short or worsen the polarizer.
(3) Its not permitted to have pressure or impulse on the module because the LCD panel and Backlight will
be damaged.
(4) Always follow the correct power sequence when LCD module is connecting and operating. This can
prevent damage to the CMOS LSI chips during latch-up.
(5) Do not pull the I/F connector in or out while the module is operating.
(6) Do not disassemble the module.
(7) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is very soft and
easily scratched.
(8) It is dangerous that moisture come into or contacted the LCD module, because moisture may damage
LCD module when it is operating.
(9) High temperature or humidity may reduce the performance of module. Please store LCD module within
the specified storage conditions.
(10) When ambient temperature is lower than 10C may reduce the display quality. For example, the
response time will become slowly, and the starting voltage of CCFL will be higher than room
temperature.
24 / 26
Version 2.0