Вы находитесь на странице: 1из 525

USERMANUAL

RADWIN5000POINTTOMULTIPOINT
BROADBANDWIRELESS
Release3.5.50

RADWIN5000HPMP
UserManual
Notice
ThismanualcontainsinformationthatisproprietarytoRADWINLtd(RADWINhereafter).No
partofthispublicationmaybereproducedinanyformwhatsoeverwithoutpriorwritten
approvalbyRADWIN.
Right,titleandinterest,allinformation,copyrights,patents,knowhow,tradesecretsand
otherintellectualpropertyorotherproprietaryrightsrelatingtothismanualandtothe
RADWINproductsandanysoftwarecomponentscontainedthereinareproprietaryproducts
ofRADWINprotectedunderinternationalcopyrightlawandshallbeandremainsolelywith
RADWIN.
TheRADWINnameisaregisteredtrademarkofRADWIN.Noright,license,orinteresttosuch
trademarkisgrantedhereunder,andyouagreethatnosuchright,license,orinterestshallbe
assertedbyyouwithrespecttosuchtrademark.
Youshallnotcopy,reversecompileorreverseassemblealloranyportionoftheUserManual
oranyotherRADWINdocumentationorproducts.Youareprohibitedfrom,andshallnot,
directlyorindirectly,develop,market,distribute,license,orsellanyproductthatsupports
substantiallysimilarfunctionalitybasedorderivedinanywayfromRADWINproducts.Your
undertakinginthisparagraphshallsurvivetheterminationofthisAgreement.
ThisAgreementiseffectiveuponyouropeningofaRADWINproductpackageandshall
continueuntilterminated.RADWINmayterminatethisAgreementuponthebreachbyyouof
anytermthereof.UponsuchterminationbyRADWIN,youagreetoreturntoRADWINany
RADWINproductsanddocumentationandallcopiesandportionsthereof.
ForfurtherinformationcontactRADWINatoneoftheaddressesunderWorldwideContacts
beloworcontactyourlocaldistributor.
Disclaimer
Theparametersquotedinthisdocumentmustbespecificallyconfirmedinwritingbefore
theybecomeapplicabletoanyparticularorderorcontract.RADWINreservestherightto
makealterationsoramendmentstothedetailspecificationatitsdiscretion.Thepublication
ofinformationinthisdocumentdoesnotimplyfreedomfrompatentorotherrightsof
RADWIN,orothers.
Trademarks
WinLink1000,RADWIN2000,RADWIN5000,RADWIN6000andRADWIN600are
trademarksofRADWINLtd

RADWIN5000HPMPUserManual

Release3.5.50

Windows2000,XPPro,Vista,Windows7andInternetExploreraretrademarksof
MicrosoftInc.
MozillaandFirefoxaretrademarksoftheMozillaFoundation.
Otherproductnamesaretrademarksoftheirrespectivemanufacturers.

RADWIN5000HPMPUserManual

Release3.5.50

ii

RADWINWorldwideOffices
CorporateandEMEARegionalHeadquarters
CorporateandEMEAHeadquarters

NorthAmericaRegionalHeadquarters

27 Habarzel Street
Tel Aviv,6971039
Israel
Tel: +972.3.766.2900
Fax: +972.3.766.2902

900 Corporate Drive


Mahwah, NJ, 07430
USA
Tel: +1-877-RADWIN US
(+1-877 723-9468)
Tel: +1-201-252-4224
Fax: +1-201-621-8911

Email:

sales@radwin.com

Email: salesna@radwin.com
Customer Support - North America:
Hours: 9 am - 6 pm EST (Mon - Fri)
Email:supportusa@radwin.com

RADWINRegionalOffices
RADWINBrazil

RADWINMexico

Av. Chucri Zaidan, 920 9


So Paulo, 04583-904
Brazil
Tel: +55.11.3048-4110

Quinto #20 Col El Centinela


Mexico, DF, O4450
Mexico
Tel: +52 (55) 5689 8970

Email:salesbr@radwin.com

Email:

RADWINPeru

RADWINIndia

Av. Antares 213


Lima, 33
Peru
Tel: +511.6285105
Fax: +511-990304095

E-13,B-1 Extn., Mohan Co-operative Industrial Estate


New Delhi, 110 044
India
Tel: +91-11-40539178

Email:

salespe@radwin.com

Email:salesin@radwin.com

RADWINPhilippines

RADWINSouthAfrica

5 Bur Bank St.


Laguna, Belair, Santa Rosa
Laguna Philippines
Tel: +63 928 7668230

P.O. Box 3554, Rivonia


Johannesburg ,2128
South Africa
Tel: +27 (0)82 551 5600

Email:

salesph@radwin.com

Email:

sales@radwin.com

RADWINItalyandSpain

RADWINCentralAmerica

Piazza Arenella 7/H


Napoli ,80128
Italy
Tel:+390815564116
Fax: +39335433620

Calle La Caada # 108-E


Jardines de la Hacienda
Ciudad Merliot El Salvador
Tel: +503 2278-5628

Email:

salesit@radwin.com

RADWINSouthEastAsia
All Season Mansion
87/38 Wireless Road Lumpinee
Bangkok ,10330
Thailand
Tel: +66811707503
Email:

salesmx@radwin.com

sales@radwin.com

Email:

sales@radwin.com

RegulatoryCompliance
GeneralNote
ThissystemhasachievedTypeApprovalinvariouscountriesaroundtheworld.Thismeans
thatthesystemhasbeentestedagainstvariouslocaltechnicalregulationsandfoundto
comply.Thefrequencybandsinwhichthesystemoperatesmaybeunlicensedandinthese
bands,thesystemcanbeusedprovideditdoesnotcauseinterference.

FCCCompliance
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital
device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable
protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipment
generates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedin
accordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.
However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.If
thisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcan
bedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrect
theinterferencebyoneormoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentandreceiver.
Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiverisconnected.
Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
Changesormodificationstothisequipmentnotexpresslyapprovedbythepartyresponsible
forcompliancecouldvoidtheuser'sauthoritytooperatetheequipment.

Warning

Warning

Itistheresponsibilityoftheinstallertoensurethatwhenusingtheoutdoor
antennakitsintheUnitedStates(orwhereFCCrulesapply),onlythose
antennascertifiedwiththeproductareused.Theuseofanyantennaother
thanthosecertifiedwiththeproductisexpresslyforbiddenbyFCCrules47
CFRpart15.204.
Itistheresponsibilityoftheinstallertoensurethatwhenconfiguringthe
radiointheUnitedStates(orwhereFCCrulesapply),theTxpowerisset
accordingtothevaluesforwhichtheproductiscertified.TheuseofTx
powervaluesotherthanthose,forwhichtheproductiscertified,is
expresslyforbiddenbyFCCrules47CFRpart15.204.

IndoorUnitscomplywithpart15oftheFCCrules.Operationissubjecttothefollowingtwo
conditions:
(1)Thesedevicesmaynotcauseharmfulinterference.

RADWIN5000HPMPUserManual

Release3.5.50

iv

Caution

OutdoorunitsandantennasshouldbeinstalledONLYbyexperienced
installationprofessionalswhoarefamiliarwithlocalbuildingandsafety
codesand,whereverapplicable,arelicensedbytheappropriate
governmentregulatoryauthorities.Failuretodosomayvoidtheproduct
warrantyandmayexposetheenduserortheserviceprovidertolegaland
financialliabilities.Resellersordistributorsofthisequipmentarenotliable
forinjury,damageorviolationofregulationsassociatedwiththeinstallation
ofoutdoorunitsorantennas.Theinstallershouldconfiguretheoutput
powerlevelofantennasaccordingtocountryregulationsandantennatype.

Warning

WhereOutdoorunitsareconfigurablebysoftwaretoTxpowervalues
otherthanthoseforwhichtheproductiscertified,itistheresponsi
bilityoftheProfessionalInstallertorestricttheTxpowertothecerti
fiedlimits.
Thisproductwastestedwithspecialaccessoriesindoorunit(IDUor
PoE),FTPCAT5eshieldedcablewithsealinggasket,10AWGground
ingcablewhichmustbeusedwiththeunittoinsurecompliance.

(2)Thesedevicesmustacceptanyinterferencereceived,includinginterferencethatmay
causeundesiredoperation.

CanadianEmissionRequirementsforIndoorUnits
ThisClassBdigitalapparatuscomplieswithCanadianICES003.
CetappareilnumriquedelaclasseBestconformelanormeNMB003duCanada.

ChinaMII
OperationoftheequipmentisonlyallowedunderChinaMII5.8GHzbandregulation
configurationwithEIRPlimitedto33dBm(2Watt).

IndiaWPC
OperationoftheequipmentisonlyallowedunderIndiaWPCGSR38for5.8GHzband
regulationconfiguration.

Unregulated
Incountrieswheretheradioisnotregulatedtheequipmentcanbeoperatedinany
regulationconfiguration,bestresultswillbeobtainedusingUniversalregulation
configuration.

SafetyPractices
ApplicablerequirementsofNationalElectricalCode(NEC),NFPA70;andtheNational
ElectricalSafetyCode,ANSI/IEEEC2,mustbeconsideredduringinstallation.

RADWIN5000HPMPUserManual

Release3.5.50

NOTES:
1.APrimaryProtectorisnotrequiredtoprotecttheexposedwiringaslongastheexposed
wiringlengthislimitedtolessthanorequalto140feet,andinstructionsareprovidedto
avoidexposureofwiringtoaccidentalcontactwithlightningandpowerconductorsin
accordancewithNECSections72554(c)and80030.
Inallothercases,anappropriateListedPrimaryProtectormustbeprovided.RefertoArticles
800and810oftheNECfordetails.
2.ForprotectionofODUagainstdirectlightningstrikes,appropriaterequirementsofNFPA
780shouldbeconsideredinadditiontoNEC.
3.ForCanada,appropriaterequirementsoftheCEC22.1includingSection60andadditional
requirementsofCAN/CSAB72mustbeconsideredasapplicable.

RADWIN5000HPMPUserManual

Release3.5.50

vi

ContentsataGlance
Part1:BasicInstallation
Chapter1:AboutthisUserManual
Chapter2:Introduction
Chapter3:SiteSurvey
Chapter4:HardwareInstallation

Part2:SectorInstallation
Chapter5:GettingStartedwiththeRADWINManager
Chapter6:InstallingtheSector
Chapter7:OperatingUndertheFCCUnrestrictedContentionBasedProtocol

Part3:SectorManagement
Chapter8:ManagingtheSector
Chapter9:DirectHSUConfiguration
Chapter10:SmartBandwidthManagement
Chapter11:BringingUpaMobilitySector
Chapter12:MonitoringandDiagnostics

Part4:SiteSynchronization
Chapter13:HubSiteSynchronization
Chapter14:SerialHubSiteSynchronization
Chapter15:HubSiteSynchronizationoverEthernet
Chapter16:UsingtheRADWINGSU

Part5:AdvancedInstallationTopics
Chapter17:SoftwareBackupandUpgrade
Chapter18:VLANFunctionalitywithRADWIN5000HPMP
Chapter19:FalseRadarMitigationFacilities
Chapter20:FCC/ICDFSConsiderations
Chapter21:QualityofService
Chapter22:CapacityUpgrade

Part6:FieldInstallationTopics
Chapter23:LinkBudgetCalculator
Chapter24:SpectrumView
Chapter25:UsingtheWebInterface

Part7:ProductReference
AppendixA:TechnicalSpecifications
AppendixB:WiringSpecifications
AppendixC:MIBReference
AppendixD:RFExposure
AppendixE:SettingAntennaParameters
AppendixF:RegionalNotice:FrenchCanadian

Index

RADWIN5000HPMPUserManual

Release3.5.50

vii

TableofContents
Notice ..................................................................................................................................................i
RADWINWorldwideOffices ..............................................................................................................iii
RegulatoryCompliance ..................................................................................................................... iv

Part1:BasicInstallation
Chapter1:AboutthisUserManual
ManualStructure ...................................................................................................................... 11
Terminology .............................................................................................................................. 13

Chapter2:Introduction
WelcometoRADWIN5000!...................................................................................................... 21
WhatsNewinRelease3.5.50................................................................................................... 22
KeyfeaturesofRADWIN5000 .................................................................................................. 24
ComponentsofaRADWIN5000PointtoMultipointSector .................................................... 25

Chapter3:SiteSurvey
PlanningtheSectorSite ............................................................................................................ 31
TheSiteSurvey.......................................................................................................................... 31
Stage1:PreliminarySurvey....................................................................................................... 32
Stage2:PhysicalSurvey ............................................................................................................ 33
Stage3:RFSurvey ..................................................................................................................... 34
RFPlanningforDenseInstallationsandCollocatedSites ......................................................... 34

Chapter4:HardwareInstallation
Overview ................................................................................................................................... 41
Whatsinthebox ...................................................................................................................... 42
Toolsrequiredforinstallation................................................................................................. 413
SafetyPracticesandProvisions............................................................................................... 414
RegulatoryConsiderationsforHSUs ....................................................................................... 416
HardwareInstallationWorkflowforaRADWIN5000Sector.................................................. 416
InstallingaVehicularMobileUnit ........................................................................................... 434
InstallationProcedure ............................................................................................................. 438

Part2:SectorInstallation
Chapter5:GettingStartedwiththeRADWINManager
Whatwewilldohere ................................................................................................................ 51
InstallingtheRADWINManagerApplication ............................................................................ 51
GettingStartedwiththeRADWINManager ............................................................................. 53
TheRADWINManagerLogonConcept .................................................................................... 58
LogonErrorsandCautions ..................................................................................................... 511
FourSectorDisplayViews ....................................................................................................... 513
ContinuingwithourExampleSector....................................................................................... 520
ExploringtheRADWINManagerMainWindowHBS............................................................ 524
ExploringtheRADWINManagerMainWindowHSU ........................................................... 534
LoggingontoaHSU ................................................................................................................ 535
SettingRADWINManagerPreferences................................................................................... 539
WhatComesNext?.................................................................................................................. 543

Chapter6:InstallingtheSector
ScopeofthisChapter ................................................................................................................ 61

RADWIN5000HPMPUserManual

Release3.5.50

viii

Concepts.................................................................................................................................... 61
WorkingwithNomadicHSUs .................................................................................................... 62
Workflow................................................................................................................................... 62
DefaultRADWIN5000HPMPSettings ...................................................................................... 63
ConfiguringtheSectoroutoftheBoxIPAddresses ............................................................... 68
TheInitialRADWINManagerMainWindow........................................................................... 610
ConfiguringafixedHSUFromtheHBS.................................................................................... 620
ConfiguringanomadicHSUFromtheHBS.............................................................................. 626
RegisteringafixedHSUforservice ......................................................................................... 627
RegisteringanomadicHSUforservice ................................................................................... 632
ChoosingDiversityAntennaModeDuringRegistration.......................................................... 635
DeactivatingtheHBS............................................................................................................... 635
DeregisteringanHSU .............................................................................................................. 637
WherehasmyHSUgone?....................................................................................................... 637
SavingtheHBSSettingsforReuseasaTemplate ................................................................... 637
CreatingNomadicEntriesforaSectorfromaHBSTemplate ................................................. 637

Chapter7:OperatingUndertheFCCUnrestrictedContentionBasedProtocol
ScopeofthisChapter ................................................................................................................ 71
BringingupaSector .................................................................................................................. 71
HSUOperation .......................................................................................................................... 72

Part3:SectorManagement
Chapter8:ManagingtheSector
ScopeofthisChapter ................................................................................................................ 81
ConfiguringaHBS...................................................................................................................... 81
HSUConnectionTable............................................................................................................. 830
ConfiguringanHSUfromtheHBSMainWindow ................................................................... 831
ReplacinganHSU .................................................................................................................... 844
UpdatingHSUServices ............................................................................................................ 846
SuspendinganHSU ................................................................................................................. 846
ChangingtheSectorBand ....................................................................................................... 847
ConfiguringAES256EncryptionSupport ................................................................................ 854
ConfigurationwithTelnet ....................................................................................................... 856

Chapter9:DirectHSUConfiguration
ScopeofthisChapter ................................................................................................................ 91
ConfiguringanHSU ................................................................................................................... 91

Chapter10:SmartBandwidthManagement
WhatisSmartBandwidthManagement................................................................................. 101
ScopeofthisChapter .............................................................................................................. 102
TerminologyandConcepts:Recapitulation ............................................................................ 102
HowSBMWorks...................................................................................................................... 104
TrafficGenerationTools.......................................................................................................... 105
TrafficGenerationExamplesandmethod .............................................................................. 105
AboutHBSOverhead............................................................................................................. 1020
TCP/IPandotherSLAConsiderations ................................................................................... 1022

Chapter11:BringingUpaMobilitySector
ScopeofthisChapter .............................................................................................................. 111
Concepts.................................................................................................................................. 111
WhatYouNeed ....................................................................................................................... 112
GettingStarted........................................................................................................................ 112
PreparingtheHBS ................................................................................................................... 113

RADWIN5000HPMPUserManual

Release3.5.50

ix

RegisteringHMUs.................................................................................................................... 116
UpdateService ...................................................................................................................... 1113
SavingtheHBSSettingsforReuseasaTemplate ................................................................. 1115
CreatingaSectorfromanHBSTemplate.............................................................................. 1115
CreatingaSectorfromanHBSTemplateandanHBSList .................................................... 1117
WiFiConnectivityforaVehicularMobileUnit...................................................................... 1117
ContinuingPreConfiguration ............................................................................................... 1121
CheckingtheGPS .................................................................................................................. 1127

Chapter12:MonitoringandDiagnostics
RetrievingLinkInformation(GetDiagnostics) ........................................................................ 121
LinkCompatibility.................................................................................................................... 124
ThroughputChecking .............................................................................................................. 126
RecentEvents.......................................................................................................................... 128
PerformanceMonitoring......................................................................................................... 129
RADWINManagerTraps ....................................................................................................... 1216
ActiveAlarms ........................................................................................................................ 1217
OtherDiagnosticAids............................................................................................................ 1218

Part4:SiteSynchronization
Chapter13:HubSiteSynchronization
WhatisHubSiteSynchronization(HSS).................................................................................. 131
RADWINHSS............................................................................................................................ 131
HSSConcepts:RadioFramePattern(RFP) .............................................................................. 134
WhichTypeofHSStoUse ....................................................................................................... 135

Chapter14:SerialHubSiteSynchronization
RADWINSerialHSS.................................................................................................................. 141
HardwareInstallation.............................................................................................................. 141
ODU/HSSUnitConnectionPinout........................................................................................... 145
SectorConfigurationandHSS ................................................................................................. 145
SyncStatusMessagesandColorCodes .................................................................................. 147

Chapter15:HubSiteSynchronizationoverEthernet
RADWINEthernetHSS............................................................................................................. 151
InstallingCollocatedHSSoEODUs........................................................................................... 153
LinkConfigurationandHSSoE ................................................................................................. 153
SyncStatusMessagesandColorCodes .................................................................................. 159

Chapter16:UsingtheRADWINGSU
Whatisitfor............................................................................................................................ 161
GSUFunctionality.................................................................................................................... 162
GSUKitContents ..................................................................................................................... 162
CommissioningandInstallation .............................................................................................. 163

Part5:AdvancedInstallationTopics
Chapter17:SoftwareBackupandUpgrade
WhatistheSoftwareUpgradeUtility? ................................................................................... 171
UpgradinganInstalledSector ................................................................................................. 172
BulkSoftwareBackup.............................................................................................................. 175

Chapter18:VLANFunctionalitywithRADWIN5000HPMP
VLANTaggingOverview ........................................................................................................ 181
ScopeofthisChapter .............................................................................................................. 181
Requirements.......................................................................................................................... 181

RADWIN5000HPMPUserManual

Release3.5.50

VLANTagging .......................................................................................................................... 182


VLANConfigurationUsingtheRADWINManager .................................................................. 186

Chapter19:FalseRadarMitigationFacilities
Whoneedsit ........................................................................................................................... 191
DFSandFalseRadarMitigation .............................................................................................. 191
ConfiguringFalseRadarMitigation ......................................................................................... 192
FCC/ICRequirements .............................................................................................................. 193

Chapter20:FCC/ICDFSConsiderations
FCC5.4GHzDeviceRegistration .............................................................................................. 201
RegisteringtheDevice............................................................................................................. 201
TDWRTable............................................................................................................................. 205

Chapter21:QualityofService
Prerequisites ........................................................................................................................... 211
QoSOverview........................................................................................................................ 211
SettingupQoS......................................................................................................................... 211

Chapter22:CapacityUpgrade
WhatisCapacityUpgrade ....................................................................................................... 221
Applicability............................................................................................................................. 221
DataGathering ........................................................................................................................ 221
Acquisition............................................................................................................................... 223
Application .............................................................................................................................. 223

Part6:FieldInstallationTopics
Chapter23:LinkBudgetCalculator
Overview ................................................................................................................................. 231
Calculations ............................................................................................................................. 232
AbouttheFresnelZone........................................................................................................... 233
RunningtheLinkBudgetCalculator ....................................................................................... 235

Chapter24:SpectrumView
WhatisSpectrumView ........................................................................................................... 241
Whoneedsit ........................................................................................................................... 241
ScopeofthisChapter .............................................................................................................. 241
TwoWaystoRunSpectrumView ........................................................................................... 242
WhereistheSpectrumViewDatastored............................................................................... 242
SpectrumViewMainWindow:HBS ........................................................................................ 242
SpectrumViewDisplayFunctionButtons ............................................................................... 245
RunningSpectrumViewfromtheHBS.................................................................................... 246
RunningSpectrumViewfromaHSU....................................................................................... 248
Zoominginandout ................................................................................................................. 249

Chapter25:UsingtheWebInterface
WhatisitFor ........................................................................................................................... 251
WhoNeedsit........................................................................................................................... 251
HowitWorks........................................................................................................................... 252
WhatitProvides...................................................................................................................... 255
Prerequisites ........................................................................................................................... 255
SpecialConsiderationsWorkingwiththeWI .......................................................................... 256
ScopeofthisChapter .............................................................................................................. 257
Loggingon ............................................................................................................................... 257
HBSManagement ................................................................................................................... 258
HSUManagement ................................................................................................................. 2514
WEBInterfaceforVMUs ....................................................................................................... 2519

RADWIN5000HPMPUserManual

Release3.5.50

xi

Part7:ProductReference
AppendixA:TechnicalSpecifications
ScopeoftheseSpecifications.................................................................................................... A1
ODUHBSandHSU/HMU......................................................................................................... A1
HSUwithACPowerFeeding ..................................................................................................... A7
VMU .......................................................................................................................................... A9
IDUH(AggregationUnit) ........................................................................................................ A11
GbEPoEDeviceIndoor,AC ................................................................................................... A13
PoEDeviceOutdoor,DC....................................................................................................... A14
GSU.......................................................................................................................................... A15
LightningProtector.................................................................................................................. A16
FastEthernetCAT5ecablerepeater ...................................................................................... A17
AntennaCharacteristics .......................................................................................................... A18

AppendixB:WiringSpecifications
ODUPoECable(HBSandHSU) ................................................................................................. B1
HBS/HSSUnitConnectionPinout.............................................................................................. B2
UserPortConnectors ................................................................................................................ B3
DCPowerTerminals .................................................................................................................. B3
SU2ACPowerTerminal ............................................................................................................ B3
VMUConnectors ....................................................................................................................... B4

AppendixC:MIBReference
Introduction .............................................................................................................................. C1
InterfaceAPI.............................................................................................................................. C2
PrivateMIBStructure................................................................................................................ C2
MIBParameters ........................................................................................................................ C3

AppendixD:RFExposure
AppendixE:SettingAntennaParameters
AntennaIssues .......................................................................................................................... E1
AboutSingleandDualAntennas............................................................................................... E1
ConsiderationsforChangingAntennaParameters ................................................................... E4

AppendixF:RegionalNotice:FrenchCanadian
Procduresdescurit.............................................................................................................. F1
Installationsurpylneetmur ................................................................................................... F3

Index

RADWIN5000HPMPUserManual

Release3.5.50

xii

ListofFigures
FIGURE21SECTORSCHEMATIC:MAINCOMPONENTS ................................................................ 25
FIGURE41LARGEHBSANDHSUFORMFACTORS .................................................................... 42
FIGURE42SMALLFORMFACTORHSU .................................................................................... 43
FIGURE43SMALLFORMFACTORHSUWITHACPOWERFEEDING ................................................ 44
FIGURE44VEHICULARMOBILEUNITFRONTPANEL ................................................................. 45
FIGURE45VEHICULARMOBILEUNITREAR ............................................................................ 45
FIGURE46VEHICULARMOBILEUNITSIDE,SHOWINGMOUNTINGEARS....................................... 45
FIGURE47VEHICULARMOBILEUNITTOP,SHOWINGMOUNTINGEARS ....................................... 46
FIGURE48GBEPOEDEVICE .................................................................................................. 47
FIGURE49RUGGEDIZEDDCPOEDEVICE ................................................................................ 47
FIGURE410IDUH.............................................................................................................. 48
FIGURE411DCTHREEPINPOWERPLUG ................................................................................. 48
FIGURE412IDUHFRONTVIEWSINGLECONFIGURATION ......................................................... 48
FIGURE413IDUHFRONTVIEWDOUBLECONFIGURATION ....................................................... 49
FIGURE414EXTERNALANTENNASFORHBS60,90OR120FLATPANEL ................................. 49
FIGURE415FLATPANELANTENNAMAYBEEXTERNALORINTEGRATED........................................ 49
FIGURE416PARABOLICDISHEXTERNALANTENNA ................................................................... 410
FIGURE417PARABOLICGRIDEXTERNALANTENNA .................................................................. 410
FIGURE418HSSINTERCONNECTIONUNIT ............................................................................. 411
FIGURE419RADWINGSUFRONTANDREARVIEW. ............................................................ 411
FIGURE420GENERALGSUCONFIGURATIONUSINGBOTHETHERNETANDANHSSUNIT ................ 412
FIGURE421RADWINLIGHTNINGPROTECTOR....................................................................... 412
FIGURE422USINGANETHERNETREPEATERWITHLIGHTNINGPROTECTORS ................................. 413
FIGURE423STANDARDFORMFACTORSTANDARDMOUNTINGKIT ............................................. 417
FIGURE424LARGECLAMP .................................................................................................. 417
FIGURE425SMALLCLAMP .................................................................................................. 417
FIGURE426ARM............................................................................................................... 417
FIGURE427ATTACHINGTHEMOUNTINGKITTOTHEPOLE ........................................................ 418
FIGURE428MOUNTINGKITINPLACEONTHEPOLE ................................................................. 418
FIGURE429MOUNTEDCONNECTORIZEDHBS ........................................................................ 419
FIGURE430MOUNTEDHBS:INTEGRATEDANTENNA ............................................................... 419
FIGURE431FLATPANELANTENNAMOUNTINGKITADAPTER...................................................... 419
FIGURE432FLATPANELANTENNAREARWITHMOUNTINGKITADAPTER ................................... 420
FIGURE433FLATPANELANTENNAMOUNTED ...................................................................... 420
FIGURE434HBS:GROUNDINGLUG ..................................................................................... 421
FIGURE435RADWINLIGHTNINGPROTECTIONKIT ................................................................ 422
FIGURE436BASICUSEOFLIGHTNINGPROTECTORS ................................................................. 423
FIGURE437EXPOSINGTHETACKYSIDEOFTHESEALINGTAPE .................................................... 425
FIGURE438STARTANDENDPOINTSFORPROTECTIVETAPINGTHEUNIT ..................................... 426
FIGURE439PROTECTINGTHEUNITJOINTSWITHVINYLTAPE ..................................................... 426
FIGURE440MOUNTEDANDSTRAPPEDTOTHEPOLE................................................................ 427
FIGURE441IDUH............................................................................................................ 427
FIGURE442IDUHPOWERCONNECTORS,GROUNDINGLUGANDPOWERPLUG............................ 428
FIGURE443IDUHFRONTPANEL ........................................................................................ 428
FIGURE444SMALLFORMFACTORHSUREAR,METALTIE ...................................................... 429
FIGURE445MOUNTINGADAPTER ........................................................................................ 430
RADWIN5000HPMPUserManual

Release3.5.50

xiii

FIGURE446SECURINGTHEMOUNTINGADAPTER .................................................................... 430


FIGURE447ATTACHINGASTANDARDMOUNTINGKIT .............................................................. 431
FIGURE448POLECLAMPSFOREXTERNALANTENNAS ............................................................... 431
FIGURE449HSU:GROUNDINGLUGSTANDARDANDSMALLFORMFACTOR ................................. 432
FIGURE450SMALLFORMFACTORHSUWITHACPOWERFEEDING ............................................ 432
FIGURE451BEEPSEQUENCEFORANTENNAALIGNMENT .......................................................... 433
FIGURE454VMUINSTALLATIONSCHEMATIC ......................................................................... 436
FIGURE455TYPICALCOMPOSITESHARKFINANTENNA,FORRADIOBROADBAND,WIFIANDGPS 436
FIGURE456MOUNTEDTWINSHARKFINANTENNAS ............................................................... 437
FIGURE457VMUPOWERWIRINGSCHEMATIC ....................................................................... 437
FIGURE51PINGINGTHEBASESTATION.................................................................................... 57
FIGURE52PINGINGTHEBASESTATIONIPV6 .......................................................................... 57
FIGURE53LOGONWINDOWIPV4........................................................................................ 58
FIGURE54LOGONWINDOWIPV6....................................................................................... 58
FIGURE55EXTENDEDLOGONWINDOW .................................................................................. 59
FIGURE56LOGONWINDOWEXPOSINGTHEUSERTYPES............................................................. 59
FIGURE57LOGONWINDOWSHOWINGSNMPSETTINGS......................................................... 510
FIGURE58UNSUPPORTEDDEVICEMESSAGE ........................................................................... 511
FIGURE59UNREACHABLEDEVICEMESSAGE ............................................................................ 512
FIGURE510INVALIDUSERTYPEORPASSWORD ....................................................................... 512
FIGURE511DEFAULTSECTORDISPLAYTABLEVIEW ............................................................... 513
FIGURE512HSUCARDS .................................................................................................... 514
FIGURE513MAPVIEWICONS.............................................................................................. 515
FIGURE514SECTORDISPLAYDEFAULTMAPVIEW................................................................. 516
FIGURE515SECTORDISPLAYLISTVIEW ............................................................................... 517
FIGURE516DEFAULTSECTORDISPLAYUTILIZATIONVIEW....................................................... 519
FIGURE517SELECTEDHBSORHSUWITHCONTEXTBUTTONBAR ............................................. 522
FIGURE518MAPCARDS .................................................................................................... 523
FIGURE519HBSMAINBUTTONMENU ................................................................................. 524
FIGURE520SECTORSTATUSPANEL ...................................................................................... 525
FIGURE521BASESTATIONDETAILPANEL .............................................................................. 525
FIGURE522EVENTSLOGPANEL ........................................................................................... 527
FIGURE523EVENTSLOGFILTERSELECTION ............................................................................ 527
FIGURE524HSUCARDINDICATINGAPROBLEM .................................................................... 528
FIGURE525HSUDISPLAYCONTEXTMENU(RIGHTCLICK) ....................................................... 528
FIGURE526HBSMAINWINDOWMAPVIEW ...................................................................... 529
FIGURE527HBS/HSUSTATUSLIGHTS ................................................................................. 530
FIGURE528NAVIGATIONTOOLBAR ..................................................................................... 530
FIGURE529HSUSTATUSCARDSINDICATINGPROBLEMS........................................................... 532
FIGURE530HSUSTATUSCARDS:LEFT:FIXEDHSURIGHT:NOMADICHSU................................. 532
FIGURE531HSUDISPLAYCONTEXTMENU(RIGHTCLICK) ....................................................... 533
FIGURE532HSUSONHBSDISPLAYEXTRACT.SCROLLRIGHTFORMOREHSUFIELDS ................. 533
FIGURE533LOGGINGONTOAHSU..................................................................................... 535
FIGURE534OPENINGRADWINMANAGERWINDOWHSU ................................................... 535
FIGURE535HSUMAINBUTTONMENU ................................................................................. 537
FIGURE536MONITORPREFERENCESHBS........................................................................... 539
FIGURE537MONITORPREFERENCESHSU .......................................................................... 540
FIGURE538ADVANCEDPREFERENCESHBS ......................................................................... 542
FIGURE539ADVANCEDPREFERENCESHSU ......................................................................... 542
FIGURE61LOGGINGONWITHFACTORYDEFAULTIPADDRESS ..................................................... 69
RADWIN5000HPMPUserManual

Release3.5.50

xiv

FIGURE62LOGGINGONWITHLOCALCONNECTION .................................................................. 69
FIGURE63MAINWINDOWFORUNCONFIGUREDHBSODU .................................................... 610
FIGURE64ACTIVATEDHBSRECOGNIZINGINSTALLEDBUTUNCONFIGUREDHSUS ......................... 620
FIGURE65HSUCONTEXTMENU .......................................................................................... 621
FIGURE66HSUREGISTRATIONDIALOG ................................................................................. 630
FIGURE67TWOREGISTEREDHSUCARDSMEDIUMVIEW ........................................................ 631
FIGURE68TWOREGISTEREDHSUCARDSEXTENDEDVIEW ...................................................... 631
FIGURE69HBSNOMADICCONFIGURATION ........................................................................... 632
FIGURE610FULLYFUNCTIONALMIXEDFIXEDANDNOMADICSECTORTABLEVIEW....................... 633
FIGURE611FULLYFUNCTIONALMIXEDFIXEDANDNOMADICSECTORMAPVIEW ........................ 634
FIGURE612PREPARINGTOUPLOADTHENOMADICFILE ........................................................... 638
FIGURE71AIRINTERFACETABFORFCCUCBP........................................................................ 72
FIGURE81VLANFORMANAGEMENT ..................................................................................... 89
FIGURE82SUPPORTEDPROTOCOLS ....................................................................................... 810
FIGURE83ADDOREDITAUSER ........................................................................................... 813
FIGURE84SNMPV3USERSLIST .......................................................................................... 814
FIGURE85DEFAULTSNMPV3LOGONDIALOG ...................................................................... 816
FIGURE86SECTORSECURITYSETTINGS .................................................................................. 819
FIGURE87CHANGELINKPASSWORDDIALOGBOX ................................................................... 820
FIGURE88LOSTORFORGOTTENLINKPASSWORDRECOVERY ..................................................... 820
FIGURE89CHANGINGTHECOMMUNITYSTRINGS/PASSWORDS ................................................. 822
FIGURE810ALTERNATIVECOMMUNITYDIALOGBOX ............................................................... 823
FIGURE811DATEANDTIMECONFIGURATION ........................................................................ 824
FIGURE812CHANGEDATEANDTIME ................................................................................... 825
FIGURE813SETTINGETHERNETSERVICES .............................................................................. 825
FIGURE814HBSCOLLOCATEDCLIENTORINDEPENDENTUNIT ................................................... 827
FIGURE815HBSCOLLOCATEDMASTER ................................................................................. 827
FIGURE816RESTOREFACTORYSETTINGSANDLICENSEACTIVATION........................................... 829
FIGURE817HSUINTERCOMMUNICATIONCONNECTIONTABLE ............................................... 831
FIGURE818HSUCONFIGURATIONWINDOW(HBS)................................................................ 833
FIGURE819HSUCONFIGURATIONSETTINGANTENNATYPEANDPARAMETERS .......................... 834
FIGURE820HSUCONFIGURATIONIPADDRESSES ................................................................. 835
FIGURE821UNIT10.104.50.1DOWN;UNIT10.104.50.3AVAILABLE,NOTREGISTERED ............. 844
FIGURE822CHANGEORADDBANDS.................................................................................... 848
FIGURE823ADD/CHANGEBANDDIALOG .............................................................................. 849
FIGURE824ADDBANDSINSTRUCTIONSPANEL....................................................................... 852
FIGURE825TELNETSESSIONLOGONTOTHEHBS .................................................................. 857
FIGURE826TELNETMANAGEMENTWINDOWHSU............................................................... 859
FIGURE91DIRECTOROVERTHEAIRCONNECTIONTOAREGISTEREDHSU ..................................... 92
FIGURE92REGISTEREDHSUEXTENDEDVIEW......................................................................... 92
FIGURE93DIRECTCONNECTIONTOASTANDALONEHSUOUTOFTHEBOX ................................... 93
FIGURE94HSUCONFIG.AIRINTERFACEFORREGISTEREDFIXEDHSU ....................................... 94
FIGURE95HSUCONFIG.AIRINTERFACEFORSTANDALONEFIXEDHSU..................................... 95
FIGURE96HSUCONFIG.AIRINTERFACE,REGISTEREDNOMADICHSUORHMU ......................... 95
FIGURE97HSUCONFIG.AIRINTERFACE,STANDALONENOMADICHSUORHMU ...................... 95
FIGURE98HSUCONFIG.AIRINTERFACEUNREGISTEREDHSU.................................................. 96
FIGURE101SERVICE(TIMESLOTS)UPDATEFORAFIXEDHSU................................................... 103
FIGURE102SERVICE(TIMESLOTS)UPDATEFORANOMADICHSUS............................................ 104
FIGURE103SECTORSTATUSFOREXAMPLE1 ......................................................................... 106
FIGURE104SECTORUTILIZATIONPANEFROMTHEMAINWINDOWFOREXAMPLE1 ..................... 107
RADWIN5000HPMPUserManual

Release3.5.50

xv

FIGURE105SECTORUTILIZATIONEXAMPLE1....................................................................... 108
FIGURE106SECTORUTILIZATIONTIMELINEEXAMPLE1 ...................................................... 109
FIGURE107HSUUTILIZATIONHSURELATIVEEXAMPLE1................................................. 1010
FIGURE108HSUUTILIZATIONHSURELATIVETIMELINEEXAMPLE1................................... 1010
FIGURE109HSUUTILIZATIONSECTORRELATIVEEXAMPLE1 ............................................. 1010
FIGURE1010HSUUTILIZATIONSECTORRELATIVETIMELINEEXAMPLE1 ............................. 1011
FIGURE1011SECTORSTATUSFOREXAMPLE2ALLDLTIMESLOTSALLOCATED ........................ 1011
FIGURE1012SECTORUTILIZATIONEXAMPLE2 .................................................................. 1012
FIGURE1013SECTORSTATUSFOREXAMPLE3ALLULTIMESLOTSALLOCATED ........................ 1013
FIGURE1014SECTORUTILIZATIONPANEFROMTHEMAINWINDOWFOREXAMPLE3 ................. 1014
FIGURE1015HSUUTILIZATIONSECTORRELATIVETIMELINEEXAMPLE3 ............................. 1014
FIGURE1016HSUUTILIZATIONSECTORRELATIVEEXAMPLE3 ........................................... 1015
FIGURE1017SECTORSTATUSFOREXAMPLE4HALFULTIMESLOTSALLOCATED ...................... 1016
FIGURE1018SECTORUTILIZATIONPANEFROMTHEMAINWINDOWFOREXAMPLE4 ................. 1016
FIGURE1019HSUUTILIZATIONSECTORRELATIVETIMELINEEXAMPLE4 ............................. 1017
FIGURE1020SECTORUTILIZATIONEXAMPLE4 .................................................................. 1017
FIGURE1021HSUUTILIZATIONHSURELATIVEEXAMPLE4............................................... 1017
FIGURE1022HSUUTILIZATIONSECTORRELATIVEEXAMPLE4 ........................................... 1018
FIGURE1023EXAMPLE3:HALFTHEUPLINKTIMESLOTSRESERVEDAT10MHZCBW................ 1020
FIGURE1024EXAMPLE3:HALFTHEUPLINKTIMESLOTSRESERVEDAT20MHZCBW................ 1021
FIGURE1025EXAMPLE3:HALFTHEUPLINKTIMESLOTSRESERVEDAT40MHZCBW................ 1022
FIGURE111MOBILEHBSAFTERINITIALLOGON .................................................................... 113
FIGURE112HBSMOBILITYCONFIGURATION ......................................................................... 114
FIGURE113CONFIGUREDMOBILITYSECTOR ........................................................................ 1113
FIGURE114PREPARINGTOUPLOADTHEMOBILITYFILE ......................................................... 1116
FIGURE121GETDIAGNOSTICSDIALOGBOXHBS ................................................................. 122
FIGURE122GETDIAGNOSTICSDIALOGBOXHSU................................................................. 123
FIGURE123TYPICALINCOMPATIBLYMESSAGESFORHSUSONHBSDISPLAY ................................ 125
FIGURE124THISHSUREQUIRESASOFTWAREUPGRADE .......................................................... 125
FIGURE125RECENTEVENTS:LEFTTORIGHT:HBS,HSUFROMHBS,HSUDIRECT...................... 129
FIGURE126PERFORMANCEMONITORING:L.TOR.HBS,HSUFROMHBS,HSU ................... 1210
FIGURE127SETTINGTHEUPPERTRAFFICTHRESHOLD............................................................. 1211
FIGURE128HBSPERFORMANCEMONITORINGREPORTVALIDDATA ................................... 1211
FIGURE129HBSPERFORMANCEMONITORINGREPORTSHOWINGINVALIDDATA................... 1212
FIGURE1210HSUPERFORMANCEMONITORINGVALIDANDINVALIDDATA(1OF3) ............. 1213
FIGURE1211HSUPERFORMANCEMONITORINGVALIDANDINVALIDDATA(2OF3) ............. 1213
FIGURE1212HSUPERFORMANCEMONITORINGVALIDANDINVALIDDATA(3OF3) ............. 1214
FIGURE131INTERFERENCECAUSEDBYCOLLOCATEDUNITS ....................................................... 132
FIGURE132COLLOCATEDUNITSUSINGHUBSITESYNCHRONIZATION(1) .................................... 132
FIGURE133COLLOCATEDUNITSUSINGHUBSITESYNCHRONIZATION(2) .................................... 132
FIGURE134RADIOFRAMEPATTERN ..................................................................................... 134
FIGURE141HSSINTERCONNECTIONUNIT ............................................................................. 142
FIGURE142HSSWIRINGSCHEMATIC ................................................................................... 143
FIGURE143HSSSYNCSIGNALPATHWITHODU1ASHSSMASTER .......................................... 143
FIGURE144CASCADINGTWOHSSUNITS .............................................................................. 144
FIGURE145CASCADINGTHREEHSSUNITS ............................................................................ 144
FIGURE146HSSSETTINGSWINDOW .................................................................................... 146
FIGURE147SETTINGHBSASHSMORHSC.......................................................................... 147
FIGURE148HBSASHSM .................................................................................................. 147
FIGURE151HSSSETTINGSWINDOW .................................................................................... 154
RADWIN5000HPMPUserManual

Release3.5.50

xvi

FIGURE152EXTENDEDPROTOCOLPARAMETERSFORHSSOE ................................................... 155


FIGURE153HSSDISCOVERYFILTERS ..................................................................................... 155
FIGURE161GENERALGSUCONFIGURATIONUSINGBOTHETHERNETANDANHSSUNIT ................ 162
FIGURE162GSUMAINWIDOWATSTARTUP ......................................................................... 164
FIGURE163GPSSTATUSUNDERNORMALUSE ....................................................................... 164
FIGURE164GSUCONFIGURATIONWINDOW ......................................................................... 165
FIGURE171SOFTWAREUPGRADEUTILITYMAINWINDOW ..................................................... 172
FIGURE172ADD/REMOVESITEBUTTONS ............................................................................ 172
FIGURE173ADDINGASINGLESITEFORUPGRADE ................................................................... 173
FIGURE174SOFTWAREUPGRADEINPROGRESSNOTETHESTOPBUTTON .................................. 175
FIGURE175SOFTWAREUPGRADECOMPLETEDSUCCESSFULLY .................................................... 175
FIGURE176BULKBACKUPSETUPWINDOW............................................................................ 176
FIGURE181VLANSCENARIOSHANDLEDBYRADWIN5000HBS ............................................ 182
FIGURE182SEPARATINGCLIENTDATASTREAMSUSINGDOUBLETAGGING ................................... 183
FIGURE191FALSERADARMITIGATION ................................................................................. 192
FIGURE231FRESNELZONE .................................................................................................. 234
FIGURE232ACCESSINGTHELINKBUDGETCALCULATOR ........................................................... 235
FIGURE233LINKBUDGETWINDOWSTARTUP ....................................................................... 235
FIGURE234RADWIN5000HPMPLBCMAINWINDOW ...................................................... 236
FIGURE235BANDSELECTOR ............................................................................................... 237
FIGURE236CALCULATIONOFDISTANCEFROMSITECOORDINATES............................................. 238
FIGURE237CLIMACTICCFACTORS ....................................................................................... 239
FIGURE238CLIMACTICCFACTORDESCRIPTION .................................................................... 2310
FIGURE239WORLDMAPSHOWINGCFACTORCONTOURS ..................................................... 2310
FIGURE2310LBCRESULTSSECTION ................................................................................. 2311
FIGURE241SPECTRUMVIEWDATAPANELFORTHEHBS,READYFORDATA................................. 245
FIGURE242SPECTRUMVIEWANALYSISCOLORCODES ............................................................. 247
FIGURE243HSUSPECTRUMANALYSISINCOMPLETEISOLATIONFROMTHESECTOR ...................... 248
FIGURE244HSUSPECTRUMANALYSISWITHINTHESECTOR ...................................................... 249
FIGURE251WEBINTERFACELOGON.................................................................................. 257
FIGURE252WEBINTERFACEMAINWINDOW,HBS .............................................................. 258
FIGURE253SECTORSTATUSPANEL ...................................................................................... 258
FIGURE254HSUHAYDNDEREGISTERED ............................................................................... 259
FIGUREC1TOPLEVELSECTIONSOFTHEPRIVATEMIB ............................................................... C3
FIGUREC2PRODUCTMIB..................................................................................................... C3
FIGUREF1GRANDECLAME .....................................................................................................F3
FIGUREF2PETITECLAME ........................................................................................................F3
FIGUREF3BRAS ....................................................................................................................F3
FIGUREF4MONTAGESURUNPYLNE ......................................................................................F4
FIGUREF5MONTAGESURUNMUR..........................................................................................F5

RADWIN5000HPMPUserManual

Release3.5.50

xvii

ListofTables
TABLE11USERMANUALGENERALLAYOUT .......................................................................... 11
TABLE21NEWANDCHANGEDFEATURESSINCERELEASE3.4.00................................................. 22
TABLE41BILLOFMATERIALS:STANDARDMOUNTINGKIT........................................................ 417
TABLE42LPUKITCONTENTS ............................................................................................. 422
TABLE43IDUHLEDINDICATORS ...................................................................................... 429
TABLE44MOUNTINGADAPTERKITFORSMALLFORMFACTORHSUS ......................................... 430
TABLE51PCREQUIREMENTSFORTHERADWINMANAGERAPPLICATION................................... 51
TABLE52PRECONFIGUREDSETUPHBS................................................................................. 53
TABLE53PRECONFIGUREDSETUPHSUS ............................................................................... 54
TABLE54PRECONFIGUREDSETUPLEVELALLOCATIONFORMAXIMUMNOMADICHSUS ................. 55
TABLE55PRECONFIGUREDSETUPONENOMADICHSU............................................................ 56
TABLE56USERTYPES,DEFAULTPASSWORDSANDFUNCTION.................................................... 510
TABLE57RADIOPLANFORASMALLSECTOR ......................................................................... 520
TABLE59HBSMAINBUTTONBARFUNCTIONS ....................................................................... 524
TABLE510HBSDETAILPANELBUTTONBARFUNCTIONS ......................................................... 526
TABLE511HBS/HSUSTATUSLIGHTCOLORCODES ................................................................ 530
TABLE512NAVIGATIONTOOLBARBUTTONFUNCTIONS .......................................................... 530
TABLE513HBSMAINWINDOWCONTEXTMENUANDBUTTONBARFUNCTIONS .......................... 534
TABLE514HSUMAINBUTTONBARFUNCTIONS .................................................................... 537
TABLE61DEFAULTSETTINGS ................................................................................................ 63
TABLE62PRECONFIGUREDSETUPHBS................................................................................. 65
TABLE63PRECONFIGUREDSETUPHSUS ............................................................................... 66
TABLE64PRECONFIGUREDSETUPLEVELALLOCATIONFORMAXIMUMNOMADICHSUS ................. 67
TABLE65PRECONFIGUREDSETUPONENOMADICHSU............................................................ 68
TABLE81SNMPV3PREDEFINEDUSERS ................................................................................ 812
TABLE82AESINDICATORSFORANHBS .............................................................................. 855
TABLE83AESINDICATORSFORANHSU .............................................................................. 855
TABLE84HBSTELNETDISPLAYCOMMANDS....................................................................... 857
TABLE85HBSTELNETSETIMMEDIATECOMMANDS ............................................................ 858
TABLE86HBSTELNETSETCOMMANDSREQUIRINGRESET .................................................... 858
TABLE87HSUTELNETDISPLAYCOMMANDS ...................................................................... 859
TABLE88HSUTELNETSETIMMEDIATECOMMANDS ............................................................ 860
TABLE89HSUTELNETSETCOMMANDSREQUIRINGRESET ................................................... 860
TABLE101TRAFFICGENERATIONEXAMPLESTIMESLOT(TS)ALLOCATION ................................ 105
TABLE102TRAFFICSTATISTICSFOREACHHSU ...................................................................... 108
TABLE111GPSSTATUSLEDS .......................................................................................... 1127
TABLE121GETDIAGNOSTICSDATAANDDESCRIPTION ........................................................... 121
TABLE122HBSPERFORMANCEMONITORINGFIELDS ........................................................... 1211
TABLE123HSUPERFORMANCEMONITORINGFIELDS .......................................................... 1214
TABLE124RADWINMANAGERTRAPMESSAGES ............................................................... 1216
TABLE131RADIOFRAMEPATTERNTABLERADWIN5000HBS........................................... 134
TABLE132RADIOFRAMEPATTERNTABLERADWIN2000 .................................................. 134
TABLE133LEGENDFORRADIOFRAMEPATTERNTABLES ......................................................... 135
TABLE141EXTERNALPULSESTATUS .................................................................................... 148
TABLE151EXTERNALPULSESTATUS .................................................................................... 159
TABLE171SWUFILESBYPRODUCT .................................................................................... 173
RADWIN5000HPMPUserManual

Release3.5.50

xviii

TABLE181PORTSETTINGSINGRESSDIRECTION .................................................................... 185


TABLE182PORTSETTINGSEGRESSDIRECTION ..................................................................... 186
TABLE183FURTHERVLANCONFIGURATIONOPTIONSANDRESULTSBYTAGMODE ................... 1810
TABLE201LATITUDEANDLONGITUDELOCATIONSOFTDWRS ................................................. 205
TABLE211DEFAULTPRIORITIESANDALLOCATIONBYVLANIDANDDIFFSERV ........................... 211
TABLE221HSUCAPACITYUPGRADELIST............................................................................. 223
TABLE241SPECTRUMVIEWANALYSISDISPLAYBUTTONSFUNCTIONALITY .................................. 246
TABLE251PRECONFIGUREDSETUPHBS............................................................................. 252
TABLE252PRECONFIGUREDSETUPHSUS ........................................................................... 253
TABLE253PRECONFIGUREDSETUPLEVELALLOCATIONFORMAXIMUMNOMADICHSUS ............. 254
TABLE254PRECONFIGUREDSETUPONENOMADICHSU ....................................................... 255
TABLEB1ODUPOERJ45CONNECTORPINOUT ....................................................................B1
TABLEB2LANGBEPOERJ45CONNECTORPINOUT ..............................................................B1
TABLEB3HBS/HSSUNITCONNECTIONPINOUT .....................................................................B2
TABLEB4FASTETHERNETCONNECTORPINOUT .......................................................................B3
TABLEB5TERMINALBLOCK2PIN48VDC ............................................................................B3
TABLEB6SU2ACPOWERPINASSIGNMENTS ..........................................................................B3
TABLEB7POWERCONNECTORFRONTVIEWANDPINOUT ........................................................B4
TABLEB8LANPOEM12CONNECTORPINOUT ......................................................................B4
TABLEB9ALARMCONNECTORPINOUT ..................................................................................B5
TABLEC1SUPPORTEDVARIABLES .......................................................................................... C4
TABLEC2PRIVATEMIBPARAMETERSHBS........................................................................... C6
TABLEC3PRIVATEMIBPARAMETERSHSU ........................................................................C39
TABLEC4MIBTRAPS ........................................................................................................C72
TABLED1SAFETYDISTANCESFORRADWIN5000HPMPFCCANDICPRODUCTS ......................D1
TABLED2SAFETYDISTANCESFORRADWIN5000HPMPETSIPRODUCTS ................................D2
TABLEE1SPATIALMULTIPLEXINGDIVERSITYSETTINGS ............................................................ E3
TABLEE2RADWIN5000HPMPAIRRATES ......................................................................... E3

RADWIN5000HPMPUserManual

Release3.5.50

xix

Part1:BasicInstallation

Release3.5.50

Chapter1:

AboutthisUserManual
ManualStructure
ThisUserManualisdividedintosevenfunctionallydistinctsectionsreflectingtheactivities
requiredtosetupaRADWIN5000HPMPsector.Thedivisionisshowninthefollowingtable:
Table11:UserManualGenerallayout
Section

GeneralContent

Purpose

BasicInstallation

Coreinformationtophysicallyinstallasector:Site
preparationandhardwareInstallation

SectorInstallation

UnderstandingtheRADWINManagerwindows.Usingthe
RADWINManagertobringupasector.

Finetuningforthebasestationandthesubscriberunits.
SectorConfiguration
UsingSmartBandwidthManagement,monitoring,
andManagement
diagnostics,bringingupamobilitysector.

SiteSynchronization

IntrasitewithHubSiteSynchronization,intersitewiththe
GPSSynchronizationUnit

Advanced
InstallationTopics

Softwareupgrade,VLAN,QoS,RadarMitigation,Dynamic
FrequencySelection(Radaravoidance),Capacityupgrade

FieldInstallation
Topics

LinkBudgetCalculator,SpectrumView,Webinterface

ProductReference

Technicalspecifications,wiringtables,MIBreference

TypographicalConvention
Whereatermisdefinedorintroducedforthefirsttime,itisshowninBoldface.

RADWIN5000HPMPUserManual

Release3.5.50

11

ViewingandPrinting

ViewingandPrinting
ThismanualisoptimizedforviewingonlineasaPDFfile.Tothisenditusesan11point
Tahomatypefaceformaintext.Tablesformostpart,use7or8pointfonts.Hereareafew
pointersforhardcopyprinting:

Thetextandtabletypefacesusedarelargeenoughtoprintthemanualattwopagesper
sheet
Forgoodlegibility,useacommercialgradelaserprinter.Acolorprinterisofcoursebest,
howeveramonochromeprintersettousegrayscalegivesacceptableresults
Betterqualityinkjetprintersalsogivegoodoutput

Notifications
NotificationsconsistofWarnings,CautionsandNotes.

Note

Warning

Caution

ThepurposeofaNoteisto
Drawyourattentiontosomethingthatmaynotbeobviousorcounter
intuitive
EmphasizeaspecialfeatureorpeculiarityoftheRADWIN5000HPMP
Offeranexternalreferenceforadditionalinformation
AddacaveatthatwouldnotqualifyasafullCautionorWarning(see
below)
Provideadditionalbackgroundtowhatfollows
Offerarecommendation
Highlightanindicationofsomethingtowatchoutfor
Adviseyouifanactionhassideeffectsi.e.itmaydisturbsomething
elsethatwouldbebestleftundisturbed
Remindyouofsomethingthatshouldbekeptinmind

AWarningisanotificationofriskofdangertopersonsoperatingnearthe
equipment

ACautionisanotificationofriskofdamagetoequipmentorofservice
degradation

OccasionallyweuseaNoteasaTip:

Thisisaboutausefulshortcutormethodnototherwiseobvious.

Tip

RADWIN5000HPMPUserManual

Release3.5.50

12

Terminology

Terminology

APointtoMultipointnetworkistypicallyabbreviatedtoPtMP.ThePtMPnetworks
describedinthisManualareofcourse,radiolinks.
APtMPlinkconsistsofatleastoneBaseStation(BS)radiolinkedtoseveralSubscriber
Unit(SU)radios.TheSUsaresometimescalledCustomerPremisesEquipment(CPEs).
Theterminologycomesfromthefieldoftelephony.
TheRADWIN5000HPMPproductsuiteprovidesthehighestcapacityandspectrumeffi
ciencyavailableinthePointtoMultipointsub6GHzband.Wedistinguishbetween
genericBSsandSUsandRADWINunits,relabelingtheformertoHBSandthelatterto
HSUs(H=highcapacity).
TheradiolinksareeffectedbyusingasectorantennawiththeHBS.TheHSUsusedirec
tionalantennasalignedtotheHBS.
ASectorconsistsofaHBSandagroupofHSUswithintheangularsectorcoveredbythe
HBSantenna.ASectoristypically60,90or120dependingonthechoiceofantenna.
HBSsmaybecollocatedtoprovidesectorialcoverageupto360.
TheRFcharacteristicsofaSectorwillbecommontoeachradio:Frequency(regulation),
bandandchannelbandwidth.AdjacentSectorsinaPtMPnetworkwilltypicallyuse
differentfrequenciesandnonoverlappingbandstomitigateHBSselfinterference.
AHSUmaybedefinedasfixed,nomadicormobile.
AfixedHSUisjustthatinstalledatafixedlocation.
AnomadicHSUisattachedtoavehiclethatmovesaboutwithinasectorandacrosssec
torsinsideawelldefinedarea.Serviceisprovidedwhenthevehicleisstationary.
AmobileHSU(HMU)providesservicewhilethevehicletowhichitisattachedismoving
orstationary.Thevehicleistypicallyarailwaycarriage,acar(automobile)oraship.A
classofHMUs,VehicularMobileUnits(VMU)provideWiFiserviceandincludeaninte
gratedGPSunit.
DownlinktrafficisdatatransferfromanHBStoanHSU.
UplinktrafficisdatatransferfromanHSUtoanHBS.
TimeslotsareassignedtoeachHSUtoprioritizethem.63timeslotsareavailablein
eachoftheuplinkanddownlinkdirections.
ForeachfixedornomadicHSU,Assuredthroughputisdeterminedbytheactualnum
beroftimeslotsallocatedtoitineitherdirection.Peakthroughput(higherthan
Assuredthroughput)maybeachievedbyallocatingunuseddownlinktimeslotsorunal
locateduplinktimeslotstoverybusyHSUs.ThisprocessiscalledSmartBandwidth
Management(SBM).SBMtakesuponetimeslotineachdirection.

RADWIN5000HPMPUserManual

Release3.5.50

13

Chapter2:

Introduction
WelcometoRADWIN5000!
RADWIN5000deliversupto250Mbpsandistheidealchoiceforlastmileenterprise
connectivityandhighendapplicationsthatdemandassuredperformancewithguaranteed
bandwidthpersubscriber.
RADWIN5000HPMPsectorbasestationdeliversupto250Mbps,providingthehighestend
usercapacityinthemarkettobestsupportdataandhighresolutionvideoapplications,today
andtomorrow.Bydeliveringhighcapacityoverasingleradiounit,RADWINsolutionsaves
valuabletowerspace,easesmaintenanceeffortsandreducesthetotalcostofownershipper
megabit.Offeringavarietyofpowerfulsubscriberunits(HSUs),RADWIN5000HPMPenables
servicecapacityofupto100Mbpsforenterprisecustomers.
TherearethreetypesofRADWIN5000subscriberunits:

Fixedpermanentlyinstalledatfixedlocations
Nomadicinstalledinavehiclethatmaymovefromonebasestationtoanother.Ser
viceisprovidedwhenthevehicleisstationary.
Mobileinstalledinanykindofmovingvehicle.Serviceiscontinuousandseamless
frombasestationsinthenetwork.Mobilesubscriberunitscanonlybeconfiguredina
Mobilesector,whichusesadifferenttypeofbasestationfromthatusedwithfixedand
nomadicunits.MobileunitsmayberegularformfactorordedicatedVehicularMobile
Units(VMUs)describedbelow.

RADWIN5000HPMPUserManual

Release3.5.50

21

WhatsNewinRelease3.5.50

WhatsNewinRelease3.5.50
GArelease3.5.50isarollupofimprovementsandnewfeaturessinceGArelease3.4.00.
ThenewandchangedfeaturesareshowninTable 21:
Table21:Newandchangedfeaturessincerelease3.4.00
Release

NewandChangedFeatures

3.4.50

SmartBandwidthManagement(DBA):
SupportedattheHBSmodeldependent
Supportforallavailable5,10,20and40MHzchannelbandwidths
SupportforallavailableFrequencyBands
TimeslotsallocationsSeparateUL/DLtimeslotsallocations(upto63time
slotsineachdirection)
SectorUtilizationEnhancedutilizationofunusedtimeslotresources
PeakrateHSUcanreachhighpeakrateofuptofullsectorcapacity
DelayImproveddelayperformance
SecuredSLASecuredSLAforeachHSU

3.4.70

SNMPv3:
SNMPv3incorporatesConfidentiality,IntegrityandAuthenticationforthe
Managementcommunication
RADWIN5000ODUssupportSNMPv3protocolwithsecuritylevelofDES
RADWIN5000ODUssupportbothSNMPv1,SNMPv3orboth
RNMSsupportsbothSNMPv1andSNMPv3
HSUMIMOModes:
EachHSUunitinthesectorcanbeconfiguretooperateunderDiversity
(parallelidenticalstreams),SpatialMultiplexing(splitstreamsformaximum
throughput)orAutoSelectionmode
Autoselectionmodeselectsthelinkmodulationandcodingscheme(MCS)
accordingtotheradiolinkconditionstoprovidehighservicequalityand
optimizedthroughputininterferedanddynamicenvironments
HBSThroughputModes:
HBSthroughputcannowbeconfiguredtoMaximumthroughputorOptimized
latencymodes:
Maximumthroughput(default)Providesthemaximumthroughput
accordingtothelinkconditions
OptimizedlatencyLowersthelinkratetominimizelatency

3.4.80

Supportfor3.650and3.700GHzFCCUnrestrictedContentionBasedProto
col(UCBP)
Supportfor6.4GHzUniversalforlowtemperature(55C)at5,10,20and
40MHzchannelbandwidth.Throughputsofbetween10and250Mbpsare
availabledependingonmodel.
Supportfor6.4GHzETSIforlowtemperature(35C)at5,10,and20MHz
channelbandwidth.Throughputsofbetween10and250Mbpsareavail
abledependingonmodel.
AES256Encryptionsupportwithlicencekey

RADWIN5000HPMPUserManual

Release3.5.50

22

WhatsNewinRelease3.5.50

Table21:Newandchangedfeaturessincerelease3.4.00(Continued)
Release

NewandChangedFeatures

3.4.85

3.5.50

AdditionofSNMPversionchoiceatlogon.Usersoperatingbehindafire
wallblockingSNMPv3messagescancircumventtheproblembycontinuing
toworkwithSNMPv1.
ThebulksectorsoftwarebackuppreviouslyavailableaspartoftheSoft
wareUpgradeprocedure,isnowavailableasastandaloneutility.Itcre
atesindividualsoftwarebackupfilesfortheHBSandeachHSUinthe
sector.ItcanalsobeinvokedfromanHSUwindowforthespecificHSU.
Mobility:
NewdedicatedHMU(VMU)foruseinalltypesofmotorvehicles
SmartBandwidthManagement(SBM)cannowbeusedinmobilitysectors
Antennamodemaynowbespatiallymultiplexed,diversityorautoselec
tion
VMUsmaybetrackedinaGoogleEarth(KMZ)filefromstoredGPSdata
HBS
TheWebInterfacefortheVMUshowsthecurrentGPSlocationanprovides
atabtodisplayaGoogleEarthmapcenteredontheVMUsposition
Ruggedvehicleunit(VMU):
Withstandsheat,cold,rain,humidity,dustandvibration
Roofmountedexternalantennasforextendrangeandperformance
Poweredfromoutsidesourceordirectlyfromthevehicle
Broadbandnetworkconnectivityfordevicesinandaroundthevehicle
FunctionasHMUorMobilityHBS(forsmallcloud)
BuiltinGPSfor:
Trackingandlocationbasedsolutions
MutualinterferenceavoidanceHBSTDDSync(1PPS)
PoE802.3afportsforexternaldevices,e.g.IPCamera
MultipleI/Oformonitoringandcontrolvariousvehiclesystems
MultibeamsmartantennaforNomadicapplications
WiFiInterface:
ConnectivityofWiFibaseddevices,functionsasAPorSTA
Unitmanagement
BuiltineMMCcardforavarietyofstorageapplications,e.g.Video

IPv6support
Supportforbothserial(standard)HSSandHSSoverEthernet
NewGSUusingeitherserial(standard)HSSorHSSoverEthernet
SupportforTTLperQoSqueueandstrictpriority
RSSindicationperhorizontalandverticalchain

RADWIN5000HPMPUserManual

Release3.5.50

23

KeyfeaturesofRADWIN5000

KeyfeaturesofRADWIN5000
General

Ethernetconnectivity
AdvancedOFDM&MIMO2x2fornLOSandNLOSperformance
Enhancedinterferencemitigationcapability
Inter&intrasitesynctoreduceselfinterference
Longrangeupto40km/25miles
Widerangeoffrequencybands2.32.7GHz,3.33.8GHz,4.96.4GHz
DedicatedBandwidthensuringSLA&latency
Lowandconstantlatencymin<3ms,typical4to20ms
Channelbandwidth5/10/20/40MHz
RegulationssupportedFCC/IC/ETSI/WPC/MII/Universal
MultibandHBSsandHSUs:2.32.4or2.52.7or3.33.8or4.96.0or5.96.4GHzinthe
sameunit
Simpletodeploy
WebInterfaceforsectormanagement(bothHBSandHSU)
SFPsupportwhenconnectingtoaIDUHinplaceofaPoEdevice

MobilityCapabilities

Upto100MbpsperHBSsectorandmobileunit
Highspeedupto250Kmperhour/150milesperhour
Longrangecoverageofupto10Km/6miles

BaseStation

HighcapacitysectorHBS
250Mbpsaggregatethroughput
Upto32SubscriberUnitsperHBS
FullyintegratedwithRADWINLegacysolutions:
Coexist(HBScollocatable)withRADWIN2000andWinLink1000products
CommonRADWINManager
CommonRNMS
SmartBandwidthManagement(SBM)usingdynamicbandwidthallocationtomaxi
mizeserviceproviderthroughputandadheretocustomerSLAs
Nomadicsupport(allHBSs)
Mobilitysupport(MobilityHBSsonly)

RADWIN5000HPMPUserManual

Release3.5.50

24

SubscriberUnits

SubscriberUnits

Highcapacity:ForFixedandNomadic,5/10/25/50/100Mbpsaggregatethroughput.
ForMobility,50/100Mbpsaggregatethroughput.
SupportscustomerSLAsbyassignmentofdedicatedbandwidthforuplinkanddown
linkperHSU,attheHBS
SeparateuplinkanddownlinkconfigurableMaximumInformationRate(MIR)perHSU
Upgradablesubscriberunitcapacityusingasoftwarekey
Fixed,nomadic,mobilitytypes

ComponentsofaRADWIN5000Pointto
MultipointSector
MajorComponents
ARADWIN5000PointtoMultipointSectorconsistsofanHBSequippedwithasector
antenna,communicatingwithupto32HSUslocatedwithinthebeamofitsantenna.

Figure21:SectorSchematic:MainComponents

RADWIN5000HPMPUserManual

Release3.5.50

25

Accessories

BoththeHBSandtheHSUscommunicaterespectively,withtheserviceproviderandusers
throughPoEdevices.Thecommunicationprotocolforboththeserviceproviderandtheusers
isEthernet.

HBSsmaybeconnectedthroughIDUHaggregationunits.

Note
Extendedradialcoveragecanbeachievedbysettingupadjacentsectorsusingcollocated
HBSs.

Accessories
TobuildaRADWIN5000sectoryouwillrequiresomeofthefollowingaccessories:

PoEdevicesBothGigabitand100Mbps
HSSunitCollocationunitforintrasiteserialsynchronization
IDUHAggregationunitforacollocatedhubsiteinsteadofmultiplePoEdevices(noHSS
unitrequired)
GSUforintersitesynchronization
AdditionalHSUtypesincludingACpoweredunits
AntennasAwidevarietyofdirectionalandsectorantennasisavailable
ODUandantennamountingkits
LightningprotectorforusewithallRADWINoutdoorproducts
EthernetrepeaterenablesyoutoextendnonGbEPoEODUcablesbeyondthe100m
limit
CAT5ecablesofvariouslengthsspecificallyforusewithRADWINradiosandPoE
devices
Groundingcables

SectorManagementTools
RADWINManager
TheRADWINManagerisanSNMPbasedmanagementapplicationwhichmanagesa
completesectoroverasingleIPaddress.ItcanalsomanageHSUsseparately.
Theintuitive,easytouseRADWINManagerhasarichgraphicaluserinterface.

RADWINWebInterfaceforManagement
TheWebInterfaceenablesyoutocarryoutbasicsectormanagementfunctionsusingaWeb
browser.Itisaneasywaytorapidlyconfigureandsetupalink.
Itmaybeusedto

Establishasectoronaminimalbasis
Checklinkparametersandmakebasicchanges

RADWIN5000HPMPUserManual

Release3.5.50

26

SectorManagementTools

ViewthelinkInventory
InspecttheRecentEventslogs

FulldetailsaresuppliedinChapter25.

RADWINNetworkManagementSystem(RNMS)
TheRADWINNetworkManagementSystemenablesServiceProviderstomanageallRADWIN
linksintheirnetworkfromaNetworkOperationsCenter(NOC).
UsingRNMS,ServiceProviderscanconfigureandmonitorupto10,000RADWINlinks1.The
intuitiveeasytouseRNMSprovidesafullrangeofnetworksurveillance,monitoring,
configurationandfaultmanagementcapabilities.Itoffersuserscompletevisibilityand
controlovertheirRADWINbasednetworks.

DocumentationsuppliedwithRADWIN5000HPMP
ThetechnicaldocumentationsuppliedwithaRADWIN5000HPMP,islocatedontheproduct
CD.Itincludesthefollowingitems:

AQuickInstallationGuideforexperiencedinstallers(alsohardcopy)
AfullUserManualthedocumentwhichyouarereading
AHelpfileaccessiblefromtheRADWINManager
LinkBudgetCalculator

1. Dependingonlicensetype

RADWIN5000HPMPUserManual

Release3.5.50

27

Chapter3:

SiteSurvey
PlanningtheSectorSite
Overview
Sectorsiteplanningconsistsofasetofsurveys,whichmustbecarriedoutbeforeany
equipmentisdeployed.Ifforsomereason,theoutcomeofanyofthesesurveysisnegative,
HBSorHSUrelocationwillneedtobeconsidered.
ASiteSurveyconsistsofthreestages:
1. PreliminarysurveyTheproposedsectorisanalyzedintheofficeusingatopographic
map.YoushoulduseadditionaltoolssuchastheLinkBudgetCalculatorortheRadioPlan
ner.
2. PhysicalsurveyThelocationsoftheindoorandoutdoorequipmentaredeterminedon
site.
3. RadioFrequency(RF)surveyItisrecommendedthattheinstallationareabescanned
withaspectrumanalyzer,toidentifyRFinterferencesoastodetermineaclearchannelfor
radioinstallation(onsite).

TheSiteSurvey
Introduction
RADWINwirelesslinksmustbeplannedbeforeinstallation.Thedesignatedinstallationsites
mustbeappraisedtodeterminethatthewirelesssystemisabletooperateefficientlyand
provideconnectivitywithoutsignaldegradation.
RADWIN5000HPMPoffersawideoperatingfrequencyrange.Afreefrequencychannelmust
bedeterminedwithintheoperatingrange,foroptimumperformance.

RADWIN5000HPMPUserManual

Release3.5.50

31

RecommendedEquipment

RecommendedEquipment
Stage1:PreliminarySurvey
Topologicalmapofthearea
Urbanmapofthearea
Compass
LinkBudgetCalculatorand/orRadioPlanner
Stage2:PhysicalSurvey
100metertapemeasure
Ohmmeter,tocheckgroundconnection
Binoculars
Map
Digitalcamera
Paper,pencil,andaclipboard
GPSdevice(optional)
Compass(optional)
Stage3:RFSurvey
SpectrumAnalyzerwithMaxHoldfunctionandscreencapturefacilitythatcanstore
multipleimages,fordocumentationpurposes
RFaccessories(connectorsandcables)
Communicationdevices(forexample,cellularphones,orasetofwalkietalkies)

Stage1:PreliminarySurvey
Apreliminarysurveyisnecessarybeforevisitingpotentialinstallationsites.Asmuchdetailas
possibleshouldbeobtainedaboutthedesignatedODUinstallationsitesandthearea
betweenthem.

Toperformapreliminarysurvey:
1.Markthedesignatedinstallationsitesonatopographicmapofthearea.
2.Measurethedistancebetweenthesites;checkthatitiswithinthespecifiedrangeof
theequipment.
3.Ontheurbanmap,checkfordevelopedareassituatedbetweentheinstallationsites.
Payattentiontotheseareaswhenperformingthephysicalsitesurvey;theremaybe
tallbuildings,RFtowers,ortransmitters,whichcouldcauseinterferencetoasector.
4.Checktheareabetweenthetwositesforobstructionssuchas:
Highgroundhillsormountains
Lakesorlargebodiesofwater.WaterhasareflectioneffectonRFsignalslikeabuild
ing.Thistypeofreflectioncausesthereceivedamplitudetobereduced.Asaruleof
thumb,thepresenceofalargebodyofwaterbetweensectorsitesmaydoublethe
requiredantennaheight.

RADWIN5000HPMPUserManual

Release3.5.50

32

Stage2:PhysicalSurvey

5.DetermineandrecordthecompassbearingsbetweenHBSandfixedHSUs,relativeto
north.
6.Ifthereareobstructionsbetweenthetwosites,calculatetheFresnelZone(see
Chapter23fordetails).
7.Ifthesiteschosendonotmeetrequirements,consideralternativesites.
8.UsetheLinkBudgetCalculator(ontheCDsuppliedwiththeequipmentorusingthe
RADWINManager)todeterminetheexpectedperformance.

Stage2:PhysicalSurvey
Thephysicalsitesurveyreviewstheenvironmentoftheproposedinstallationlocation,to
ensurethatthesectorsitesaresuitableforthewirelessnetwork.Theresultsofthephysical
sitesurveyshouldberecorded.
Itisadvisabletogoonaclearday,soyoucanmoreeasilyseeany
obstructionsbetweenthetwosites.

Note
Inwhatfollows,ODUmaybeanHBSorafixedHSU:

Toperformaphysicalsurvey:
1.Fromthecompassreadingstakeninthepreliminarysurvey,findtheazimuth(hori
zontalposition)thateachfixedHSUshouldfacetowardstheHBS.
2.Usingbinoculars,locateanyobstructionssuchastalltrees,highbuildings,hillsor
mountains.LookforotherRFtowersbetweenthetwosites.Markthelocationsof
theobstructionsonthemap.
3.DeterminethelocationfortheODUs(havingregardforexistingrooftopinstallations
andtowerspace).Theyshouldbeaboveanyobstructions,consideringtheFresnel
zone(seeChapter23).
4.IfyouneedtoinstallanytypeofODUonatower,makesurethatthetowerisfar
enoughfromoverheadelectricpowerlines.
5.Determinealocationfortheindoorequipment;itshouldbeascloseaspossibleto
theODU.Atanexistingsite,thereisprobablyanequipmentroomwithcablerouting
channels.
OutdoorCAT5e;Maximumcablelength:100mfor10/100BaseTand75m
for1000BaseT(GbEPoEs)

Note
6.MeasureandrecordthepathlengthofthecablefromeachODUpositiontothe
indoorequipmentroom.

RADWIN5000HPMPUserManual

Release3.5.50

33

AdditionalOutdoorSiteRequirements

7.Determinethegroundandlightningconnectionpointsoftheinstallation.TheODU
andPoEmustbothbegrounded.
8.UsingtheOhmmeter,measureandrecordtheresistanceoftherequiredinstallation
tothegroundingpoint.Theresistancemustbelessthan1Oohm.
9.Reviewtheresultsofthephysicalsitesurvey.Decideifthesiteissuitableforthe
wirelessnetworkinstallation.
Ifthesiteissuitable,continuewithstage3,theRFsurvey
Ifthesiteisnotsuitable,surveyanothersite

AdditionalOutdoorSiteRequirements
Theambientoutdooroperatingtemperatureshouldbe35to60C(31to140F).

AdditionalIndoorSiteRequirements
Theambientoperatingtemperatureshouldbe0to50C(32to122F)atahumidityofupto
90%,noncondensing

Stage3:RFSurvey
TheRFsurveyexaminesthewirelessenvironmentoftheinstallationsite,todetermine
whetherthereareavailablechannelswithintheradiooperatingfrequencyband.AnRF
surveyisperformedusingaspectrumanalyzer.
Itisadvisabletofamiliarizeyourselfwiththespectrumanalyzerbeforegoingoutonsite,
specificallytheMaxHoldandMarkerfunctions.
YoushouldperformtheRFsurveyateachoftheproposedsectorsites.
Thesurveyshouldbecarriedoutduringabusytimeofday,tobestjudgetheworstcaseradio
interference.Allow24hoursdurationforagoodRFsurvey.

RFPlanningforDenseInstallationsand
CollocatedSites
Interferencemayarisefrom

SelfinterferencefromcollocatedRADWINradios
Othercollocatedradiodevicesinstalledonthesamesite.

Toavoidorminimizeinterference,followtheserecommendations:

ForcollocatedRADWINunits,useanHSSunittosynchronizebetweenthem.Selecta
differentoperatingchannelforeachcollocatedRADWINunit.

RADWIN5000HPMPUserManual

Release3.5.50

34

RFPlanningforDenseInstallationsandCollocatedSites

IfoneormorecollocatedunitsarenotRADWINunits,ensurethatthereisaphysical
separationofatleastthreemetersbetweenaRADWINunitandanyothercollocated
radioonthesite.
Usethelargestpossiblefrequencygapbetweentheseunits
Choosethebestfrequencychannel(asclearaspossiblefrominterference).Youmaybe
abletochangethebandusedforthesectordependingonHBSmodelandregulations.
DecreasingtheTxPowerofasectorwillreducecollocationinterference
UsetheLinkBudgetCalculatortodeterminetheminimumTxPower
requiredtomaintainsectorstability.

Note

RADWIN5000HPMPUserManual

Release3.5.50

35

Chapter4:

HardwareInstallation
Overview
Thischaptercoverstherequirementsandproceduresforthehardwareinstallationand
alignmentofaRADWIN5000HPMPsectorinaccordancewithpriorplanning.(SeeChapter
3.)Itisintendedtoassistqualifiedfieldtechnicians.
ThematerialinthischapterislargelygenerictoallRADWINradioproducts
unlessstatedotherwise.ODUmaybeanHBSoranytypeofHSU.

Note

Warning

OutdoorunitsandantennasshouldbeinstalledONLYbyqualifiedfield
technicianswhoarefamiliarwithlocalbuildingandsafetycodesand,
whereverapplicable,arelicensedbytheappropriategovernment
regulatoryauthorities.Failuretodosomayexposetheenduserorthe
serviceprovidertolegalandfinancialliabilities.RADWINanditsresellersor
distributorsarenotliableforinjury,damageorviolationofregulations
associatedwiththeinstallationofoutdoorunitsorantennas.

Thischaptercoversthefollowingtopics:

Unpackingandcheckingsuppliedequipment:
HBSsandHSUs
PoEdevices
IDUHaggregationunit
Antennas
Accessories
Toolsrequiredforinstallation
Safetypractices
MountinganODU
ConnectinganODU
GroundingandlightningprotectionforanODU

RADWIN5000HPMPUserManual

Release3.5.50

41

Whatsinthebox

Networkconnection
Poweringup
Establishingaradiolink

Whatsinthebox
UnpackingandChecking

Foreachoftheitemsbelow:
1.Removetheequipmentfromthebox.
2.CheckthateverythinglistedontheenclosedBillofMaterialsorProformaInvoiceis
present.
3.Ifanyitemismissing,contactCustomerService.Youwillbeadvisedifthepackage
shouldbereturnedforreplacement,orifthemissingitemwillbesupplied
separately.
4.Donotdisposeofthepackaginguntiltheunitisinstalledandoperational.

BaseStationRadios
TheRADWIN5000HPMPHBS packageincludesthefollowingitems:

OneHBSseethefollowingfigureforfrontandrearviews
Rear

IntegratedAntenna

Connectorized

Front

Figure41:LargeHBSandHSUFormFactors
RADWIN5000HPMPUserManual

Release3.5.50

42

SubscriberUnits

AnHBSmountingkit
ACDcontaining
TheRADWINManagersoftware
QuickStartGuide
UserManual
LinkBudgetCalculator
AselfadhesivelabelwiththeMACaddressandalternativeCommunitystring.Keepthis
labelinasafeplaceforfuturereference.
Cableglands(tobeusedwiththeHBSPoEcable)
QuickStartGuideleaflet

SubscriberUnits
TheRADWIN5000HPMPHSU packageincludethefollowingitems:

OneHSULargeformfactorasshowninFigure 41orsmallformfactorasshownin
Figure 42.
Rear

IntegratedAntenna

Connectorized

Front

Figure42:SmallformfactorHSU
FurthertoFigure 42above:

Integrated Antenna ODU

ThisODUhasanintegrated370mm(1.2ft)flatpanelantenna.TheODUcontains
boththeradioandtheantennaasasingleunithousedinaweatherproof(IP67)
case.

Connectorized ODU

ThisODUhas2xNtypeconnectorsforconnectinganexternalantenna
RADWIN5000HPMPUserManual

Release3.5.50

43

MobileSubscriberUnittheHMU

Small Form Factor HSU with AC power feeding

ThesmallformfactorHSUhasanintegratedflatpanelantenna.IthasadirectAC
powerinlet,aLANportandaPoEoutportthatcanconnecttoapowereddevice
suchasavideocamera.

Figure43:SmallformfactorHSUwithACpowerfeeding

Embedded (Connectorized) ODU

TheEmbeddedODUhastwoNtypeconnectorsforanexternalantennaanda
builtinlowgainantenna.

AsmallformfactorHSUmountingkithasamountingkitadapterandtwometalties.
ACDcontaining
TheRADWINManagersoftware
QuickStartGuide
UserManual
LinkBudgetCalculator

AselfadhesivelabelwiththeMACaddressandalternativeCommunitystring.Keepthis
labelinasafeplaceforfuturereference.
Cableglands(tobeusedwiththeHSUPoEcable)

MobileSubscriberUnittheHMU
TheRADWINHMUisalargeformfactorunitasshowninFigure 41.Itisintendedforusein
railwayapplications,vesselsandmore.Itusestwosinglepoleantennas.

MobileSubscriberUnittheVehicularMobileUnit
TheVehicularMobileUnitisaruggedizedMobileRadioUnit(VMU),speciallydesignedfor
deploymentinvehiclesorinafullyoutdoorenvironment,connectingdirectlytothevehicle
powersource.
TheVehicularMobileUnit

CommunicateswithRADWIN5000HBSs.Itprovideshighcapacityaccessconnectivityof
upto50Mbpsnetaggregatethroughput
Supportsmultifrequencybandsfrom4.9to6.0GHzandcomplieswithFCC,IC(Canada)
WPC(India),MII(China)anduniversalregulations

RADWIN5000HPMPUserManual

Release3.5.50

44

MobileSubscriberUnittheVehicularMobileUnit

ProvidesWiFiaccesspointfunctionalitythatallowsconnectivityofmultipleWiFi
devicesinandaroundthevehicle tothebroadbandbackhaul
IncorporatesbuiltinGPSsupport

Figure44:VehicularMobileUnitFrontpanel

Figure45:VehicularMobileUnitRear

Figure46:VehicularMobileUnitSide,showingmountingears

RADWIN5000HPMPUserManual

Release3.5.50

45

MobileSubscriberUnittheVehicularMobileUnit

Figure47:VehicularMobileUnitTop,showingmountingears

HighlightsoftheVehicularMobileUnit

Ruggedizedvehicleunitthatwithstandsheat,cold,rain,humidity,dustandvibration
Roofmountedexternalantennasforextendedrangeandperformance
Broadbandnetworkconnectivityfordevicesinandaroundthevehicle
HighCapacityMobileUnitupto50Mbps
Widecoverageupto10km(6miles)
Highspeedupto250Km/h(150miles/h)
802.11b/g/nAccessPointfunctionalityforWiFidevices
BuiltinGPSforvehicletrackingandlocationbasedsolutions
PoE802.3afportforexternalpowereddevices,e.g.IPCamera
Connectsdirectlytothevehiclepowersource
Outstandingshortandconstantlatency
Singleradiosupportsmultiplebands
Robustandreliableoperationinharshenvironmentandextremetemperatures
Easeofoperationandmaintenance

RADWIN5000HPMPUserManual

Release3.5.50

46

PoweroverEthernet(PoE)Devices

PoweroverEthernet(PoE)Devices
RADWINsGigabitPoweroverEthernet
(GbEPoE)deviceprovidesdataand
powertoRADWIN5000outdoorunits.
ThePoEdeviceisavailablewitha
varietyofACcablesofferingvarious
plugtypes.
ThisistherecommendedPoEdevicefor
usewithHBSsandHSUs.
TheunitcomeswithaVACcable.The
cablelengthandplugareregion
dependent.
Figure48:GbEPoEdevice
TheOutdoor(Ruggedized)DCPoEdevicemaybeusedfor
boththeHBSandtheHSUs.ItdoesnotsupportGigabit
performanceontheHBS.Twomodelsareavailableusing
powerinputof20to60VDCor10to30VDC.Theunitcanbe
installedinavehicleusingrespectively24VDCor12VDC
powercircuits.

Figure49:RuggedizedDCPoEDevice

IDUHaggregationunit
TheIDUHprovidesaggregationformultipleRADWINODUsandHBSsatasinglehubsite.It
supportsallRADWINODUsandfeatures

SixPoEports(PoElegacymode/RADWINPoE)
Upto25WperPoEport
TwoLANInterfaces10/100/1000Mbps;autonegotiation
SFPInterfaces:2xSFPportsof1000Mbps(standardMSA)

TheIDUHisa19rackmounted,1Uandhalfwidthunit.Powerfeedingis44VDC56VDC,
DualredundantinputsthroughstandardIDUCtypeadapters.

RADWIN5000HPMPUserManual

Release3.5.50

47

IDUHaggregationunit

Figure410:IDUH
TheIDUHpackagecontains:

OneIDUH
Oneshortmountingear
Onelongmountingear
Onedualconnectortojointwounitsmountedsidebyside
TwoDCpowerplugsforpowercablesseeFigure 411below

Figure411:DCthreepinpowerplug
Thepowerconnectorsare3pininlinefemale,withpolarities(lefttoright)minus,groundand
plus.Ifrequired,anAC/DCpoweradaptershouldbeorderedseparately,dependingonthe
region.
TheIDUHmaybeinstalledinsingleordoubleconfigurations:

Figure412:IDUHfrontviewsingleconfiguration

RADWIN5000HPMPUserManual

Release3.5.50

48

ExternalAntennas

Figure413:IDUHfrontviewdoubleconfiguration

ExternalAntennas
HBS:SectorAntennas
TheHBSrequiresadualpolesectorantenna.

Figure414:ExternalAntennasforHBS60,90or120flatpanel

HSU:DirectionalAntennas
HSUsmayuseanysuitabledualpoledirectionalantenna.

Figure415:FlatPanelantennamaybeexternalorintegrated

RADWIN5000HPMPUserManual

Release3.5.50

49

Accessories

Figure416:ParabolicDishexternalantenna

Figure417:ParabolicGridexternalantenna

AntennaKits
ExternalantennasareavailablefortheRADWIN5000HPMPradios,varyinginoperating
frequencies,formfactor,sizeandgain.
SeetheRADWINproductscatalogforamoredetailedofferingofexternalantennas.External
Atypicalantennakitcontains

Anantenna
TwoRFcables1.2m(4)long
Mountingkit

Accessories
HubSiteSynchronization(HSS)Unit
TheHSSunitsynchronizescollocatedODUstopreventselfinterference.Itisparticularly
usefulatamultisectorbasestationemployingseveralHBSs.

RADWIN5000HPMPUserManual

Release3.5.50

410

Accessories

AsingleHSSunitsupportsuptotencollocatedODUs.Inadditiontoeachunitbeing
connectedtoitsPoEdevice,thecollocatedunithasanadditionalcablethatisconnectedto
theHSSUnit.TheHSSUnitisacompact,weatherproof(IP67)connectorboxthatisinstalled
onthesamemastastheODUs.AllcollocatedunitsconnecttothisboxusinganHSScable.A
varietyofcablesofdifferentlengthsareavailableforpurchase.
TheHSSunitissuppliedwithtenprotectivecovers;anyportnotinusemustbeclosedwitha
protectivecover.

Figure418:HSSInterconnectionUnit
SeeChapter13forfurtherdetailsabouttheuseofHSS.

RADWINGSU
TheGPSbasedsynchronizationunit(GSU)isdesignedtohandleintersiteinterferencesin
largescaledeploymentscenarios.
TheRADWINGSUisasmallformfactoroutdoorunitconsistingofGPSantennaandaPoE
device.

Figure419:RADWINGSUfrontandrearview.
TheRADWINGSUmaybeoperatedoverEthernetorconnectedtoanHSSUnitusinga
standardHSScable.ItsynchronizesthetransmissiontimingofmultipleHubSitestothesame
clocksourcethuseliminatingselfinterference(seeChapter16).
RADWIN5000HPMPUserManual

Release3.5.50

411

Accessories

Figure420:GeneralGSUconfigurationusingbothEthernetandanHSSunit

LightningProtectorUnit(LPU)
Theuseoflightningprotectionisdependentonregulatoryandenduserrequirements.The
RADWIN5000ODUisdesignedwithsurgelimitingcircuitstominimizetheriskofdamagedue
tolightningstrikes.ItisdesignedforusewithRADWINproducts.

Figure421:RADWINLightningProtector
Thelightningprotectorincorporateshighpowergasdischargetubeandcurrenttransistor
protectioninasingleprotectorunit.TechnicalspecificationsarelistedinAppendixA.

EthernetcableRepeater
TheRADWINEthernetrepeaterenablesyoutoextendthePoEtoODUcablebeyondthe
100mlimit(butnomorethan200m).Theunitissimilarinappearancetothelightning
protectiondeviceinFigure 421.Itsuseisverysimpleasshowninthefollowingschematic:
RADWIN5000HPMPUserManual

Release3.5.50

412

Toolsrequiredforinstallation

Figure422:UsinganEthernetrepeaterwithlightningprotectors

TheEthernetrepeatercannotbeusedwithGbEIDUODUcables.

Note

Toolsrequiredforinstallation
ThefollowingisalistoftheequipmentandmaterialsrequiredtoinstallRADWIN5000HPMP
hardware.

ToolsandMaterials

CrimpingtoolforRJ45(iftheODUPoEcableiswithoutconnectors)
Spanner/wrench13mm()
Drill(forwallmountingonly)
Cableties
Sealingmaterial
WaterproofingtapesuchasScotch23Tapewide,from3MtoensureIP67compliant
protectionagainstwateranddust

RADWIN5000HPMPUserManual

Release3.5.50

413

Cablesandconnectors

Cablesandconnectors

ODUgroundingcable10AWG
ODUPoEcable(outdoorclass,CAT5e,4twistedpairs,24AWG):
Upto100m.for100BaseTconnection.
Fora1000BaseTconnection(HBSonly)useanODUPoEcablenolongerthan75m.

Note

For1000BaseT,youshoulduseRADWINsuppliedODUPoEcables,which
guarantees1Gbperformance.RADWINcannotguarantee1Gb
performanceifyouusethirdpartycables.

ExternalCAT5ecablediametershouldbebetween79mmtoensurewaterproof
sealing.

SafetyPracticesandProvisions
PreventingOverexposuretoRFEnergy
ToprotectagainstoverexposuretoRFenergy,installtheODUssoastoprovideandmaintain
minimalseparationdistancesfromallpersons.
Whenthesystemisoperational,avoidstandingdirectlyinfrontoftheantenna.StrongRF
fieldsarepresentwhenthetransmitterison.TheODUmustnotbedeployedinalocation
whereitispossibleforpeopletostandorwalkinadvertentlyinfrontoftheantenna.

Grounding
AllRADWINproductsshouldbegroundedduringoperation.Inaddition:

AllODUsshouldbeearthedbyawirewithdiameterofatleast10AWG.
RADWIN5000HPMPODUsmustbeproperlygroundedtoprotectagainstlightning.Itis
theuser'sresponsibilitytoinstalltheequipmentinaccordancewithSection810ofthe
NationalElectricCode,ANSI/NFPANo.701984orSection54oftheCanadianElectrical
Code.Thesecodesdescribecorrectinstallationproceduresforgroundingoutdoorunits,
masts,leadinwiringanddischargeunits.Italsolaysdownthesizeofgrounding
conductorsandconnectionrequirementsforgroundingelectrodes.RADWIN5000
HPMPODUsmustbegroundedtoaProtectiveEarthinaccordancewiththeLocal
ElectricalRegulations.
TheearthlugonanIDUHshouldbeconnectedtotheprotectiveearthatalltimes,bya
wirewithadiameterof18AWGorwider.Rackmountedequipmentshouldbe
mountedonlyinearthedracksandcabinets.

Further,youshould

Alwaysmakethegroundconnectionfirstanddisconnectitlast
Neverconnecttelecommunicationcablestoungroundedequipment

RADWIN5000HPMPUserManual

Release3.5.50

414

ProtectionagainstLightning

Ensurethatallothercablesaredisconnectedbeforedisconnectingtheground

ProtectionagainstLightning
Theuseoflightningprotectionisdependentonregulatoryandenduserrequirements.All
RADWINoutdoorunitsaredesignedwithsurgelimitingcircuitstominimizetheriskof
damageduetolightningstrikes.RADWINrecommendstheuseofadditionalsurgearrestor
devicestoprotecttheequipmentfromnearbylightningstrikes.

General

Itisrecommendedthatinstallationofoutdoorunitsbecontractedtoaprofessional
installer
Beforeworkingonequipmentconnectedtopowerlinesortelecommunicationlines,
youshouldremovejewelryoranyothermetallicobjectthatmaycomeintocontact
withenergizedparts
Useextremecarewheninstallingantennasnearpowerlines
Useextremecarewhenworkingatheights
WhenusinganACpowersourceforRADWINdevices,alwaysusetheACpoweradapter
suppliedbyRADWIN
Usetherighttools!
DonotmountanODUupsidedownorhorizontally.Doingthismayvoidyouproduct
warranty.

InternalESDProtectioncircuits
RADWINequipmentisdesignedtomeettheETSI/FCC/Aus/NZ/CSAEMCandSafety
requirements.Tofulfilltheserequirements,thesystem'sTelecomlinesattheODU/PoEare
TransformerisolatedandincludeinternalESD(ElectroStaticDischarge)Protectioncircuits.

RADWIN5000HPMPUserManual

Release3.5.50

415

RegulatoryConsiderationsforHSUs

RegulatoryConsiderationsforHSUs

Warning

Caution

WheninstallinganACpoweredHSU:TomaintainOvervoltage
(Installation)CategoryII,installasuitablesurgesuppressordeviceinthe
branchcircuittolimitexpectedtransientstoOvervoltageCategoryII
values.
ThelimitsarebasedonIEC60664andarealsolocatedinTable2Hof
UL60950(formains150V,thetransientratingis1500V;for150V<mains
300V,thetransientratingis2500V;andfor300V<mains600V,the
transientratingis4000V).
ForoperationoftheRADWIN55xxHSUunderFCC/ICRegulations:
Whenoperatingthedevicewithcertain29dBidishantennas,theTxpower
maybenomorethan23dBminthefrequencychannel5845MHzfor5and
10MHzchannelbandwidth.PleasecheckwithRADWINCustomerService
forantennamodelssubjecttothisrequirement.
AllotherfrequenciesmayoperateusingmaximumTxpowerof25dBm.

HardwareInstallationWorkflowforaRADWIN
5000Sector
InstallingtheBaseStation
SiteSurvey
TheSiteSurveyiscarriedoutasdescribedinChapter3.RecallthattheSiteSurveyhasthree
mainsteps:

Stage1:PreliminarySurvey

Stage2:PhysicalSurvey
Stage3:RFSurvey

Sitepreparation
SitePreparationincludes

Obtaininganynecessarylegalandstatutorypermitsforinstallationofradioequipment
Clearingphysicalobstructionsasfaraspossible
Erectingamastortowerifrequired.AmastsitedODUtypicallyusesapoleattachedto
themast.
Installingapoleonabuildingwallifrequired
ConstructingaweatherproofcabinettohouseaPoEdeviceifitisnottobehoused
indoors
Ensuringavailabilityofpower,typicallystandardlocalACpower
EnsuringthatthereisaLANcableinplacefromtheusersswitchtothePoElocation

RADWIN5000HPMPUserManual

Release3.5.50

416

InstallingtheBaseStation

MountingtheHBS
UseamountingkittomounttheHBSonapoleasshowninthefollowingfigures:

Figure423:StandardformfactorStandardMountingkit

Figure424:LargeClamp

Figure425:SmallClamp

Figure426:Arm

Table41:BillofMaterials:Standardmountingkit
Item
Description
No.

Quantity

LargeClamp(seeFigure 424)

SmallClamp(seeFigure 425)

Arm(seeFigure 426)

ScrewhexheadM8x40

ScrewhexheadM8x70

WasherflatM8

RADWIN5000HPMPUserManual

Release3.5.50

417

InstallingtheBaseStation

Table41:BillofMaterials:Standardmountingkit(Continued)
Item
Description
No.

Quantity

WasherspringM8

M8Nuts

Figure427:Attachingthemountingkittothepole

Figure428:Mountingkitinplaceonthepole

Note

WhenmountinganHBSonapoleorwall,ensurethattheunitisori
entedsothatthecableconnectorsareatthebottom.
DonotmountanHBShorizontally
Ensurethattherearenodirectobstructionsinfrontofanintegrated
antennaHBSorinterferencefrommanmadeobstacles.

RADWIN5000HPMPUserManual

Release3.5.50

418

InstallingtheBaseStation

Figure429:MountedconnectorizedHBS
Figure430:MountedHBS:Integratedantenna
Thepurposeofthearm(Figure 426),istoenablesinglepoleantennas(deprecated)tobe
rotatedthrough90forcorrectverticalalignmentorsimplytodistancetheantennaorODU
fromthepole.

MountinganHBSExternalAntenna
TheHBSrequiresasectorantenna.Typically,aflatpanelantennasuchasthatshowin
Figure 414isused.Ithasfourboltsforamountingkitadapter.

Figure431:Flatpanelantennamountingkitadapter
ItismountedonapoleinexactlythesamemannerastheHBSitselfusingtheadaptershown
inFigure 431.Thelefthandviewinshowstheknurledsurfaceadjacenttothemountingkit
ear.Therighthandviewshowstherecessforthemountingkitholdingnut.

RADWIN5000HPMPUserManual

Release3.5.50

419

InstallingtheBaseStation

Figure432:FlatPanelantennarearwithmountingkitadapter

Figure433:FlatPanelantennamounted

GroundinganHBSexternalantenna
ExternalantennasshouldbeindividuallygroundedusingasuitableGroundingKitsuchasan
AndrewType2231582(http://www.commscope.com).

GroundingtheHBS
ThereisagroundinglugontherearoftheHBSasshowninFigure 434.Connectittoground
using10AWGwire.Groundingisoftencarriedoutinconjunctionwithlightningprotection.
RADWIN5000HPMPUserManual

Release3.5.50

420

InstallingtheBaseStation

Figure434:HBS:Groundinglug

InstallingaPoEdevice
ThePoEdevice(Figure 48)isaverysimplepieceofequipment.IthasarecessedthreepinAC
powerplug,amatchingpowercable,aLANInport(fromaswitch),aLANOutport(tothe
HBS)andapowerLED,greenundernormaloperation.Itistypicallystrappedintoanetwork
equipmentrackusingplasticties.Itmayalsositfreeonatrayortabletop.

ConnectingtheHBStothePoEdevice
ConnecttheHBStotheLANOutportonly.ItwillnotworkontheLANInport.

ConnectingthePoEDevicetoaNetwork
ConnectthePoEtonetworkequipmentsuchasaswitchfromtheLANInport.Connecting
networkequipmenttotheLANOutportmaydamageit.

PoweringuptheHBSfromaPoeDevice
ConnectingtheHBSportlabelledIDUtoapoweredupPoEissufficient.Ifyouhavenot
alreadyclosedandweathersealedtheHBSIDUport,theninsideityoucanseeanamber
coloredpowerLEDwhichturngreenwhentheHBSisactivated.(SeeChapter5.)

MountingtheLightningProtectionUnits
Theuseoflightningprotectionisdependentonregulatoryandenduserrequirements.The
RADWIN5000HPMPODUisdesignedwithsurgelimitingcircuitstominimizetheriskof
damageduetolightningstrikes.RADWINrecommendstheuseofadditionalsurgearrestor
devicestoprotecttheequipmentfromnearbylightningstrikes.
Inwhatfollows,ODUmaybeanytypeofRADWINoutdoorradiounitandIDUmaybeany
typeofRADWINIDUusedwithsuchproducts(PoEs,IDUH,etc).

RADWIN5000HPMPUserManual

Release3.5.50

421

InstallingtheBaseStation

Figure435:RADWINLightningProtectionKit
Table42:LPUKitcontents
Item

Qty

LPU(shown
wrapped)

Uwallclamp

RJ45
connectors
(shown
wrapped)

View/Remarks

RADWIN5000HPMPUserManual

Release3.5.50

422

InstallingtheBaseStation

Table42:LPUKitcontents(Continued)
Item

Qty

0.5mCAT5e
cable

Metaltie

Quick
Installation
Guide

View/Remarks

Pamphlet

ForanytypeofIDUODUconnection,lightningprotectionunits(LPUs)areinstalledinpairs,as
showninthenextfigure:

Figure436:Basicuseoflightningprotectors

RADWIN5000HPMPUserManual

Release3.5.50

423

InstallingtheBaseStation

ToinstallaLPUonapoleadjacenttoanODU(HBSorHSU):
1.MountoneLPUonthe
ODUpole,ascloseas
possibletotheODU.
2.GroundtheLPUtothe
poleusingthegrounding
lug.
3.Connectthe0.5meter
CAT5ecabletotheIDU
portoftheODU.
4.Connecttheotherendof
thecabletothetopof
theLPU.
5.TightenthetopcableLPU
glandcap.
6.ConnectthemainODU
IDUcablefromtheIDUtothebottomendoftheLPU.
7.TightenthebottomcableLPUglandcap.
8.RunthemainODUIDUcabletowardstheIDUlocation.
9.InsulatebothLPUconnections.Seethenextsection,AdditionalConsiderationsfor
Waterproofing below.

ToinstallaLPUonawalladjacenttoanIDU(PoEorIDUH):
1.Usethesuppliedwall
clamptomountthe
secondLPUasclose
aspossibletothe
indooraccesspoint
totheIDU.
2.GroundtheLPUto
anearthstripusing
thegroundinglug.
3.Removethetop
cableLPUglandcap
togetherwiththe
rubbersealingtube.
4.ThreadtheIDUcable
fromtheupperLPU,throughtheremovedcapfromthepreviousstep.
5.PlugitintothetopoftheLPU.
6.ScrewdownandtightentheLPUcap.

RADWIN5000HPMPUserManual

Release3.5.50

424

InstallingtheBaseStation

7.Connectthe0.5mCAT5ecabletotheBottomoftheLPU.
8.Connecttheotherend(viatheindooraccesspoint)totheIDU.
9.InsulatebothLPUconnections.Seethenextsection,AdditionalConsiderationsfor
Waterproofing below.

AdditionalConsiderationsforWaterproofing
LightningProtectorsandEthernetRepeaters
Iftheseunitsareinstalledatlocationsheavilyexposedtoheavydust,rainorcorrosive
moisture(forexample,closetothesea),youshouldprotectthemfurtherasinthefollowing
procedure.Intheremainderofthissection,unitreferstoeitheraLightningProtectionUnit
oraRepeater.

Tosealaunitagainstexcessivedustandmoisture:
1.ObtainahighqualitysealingmaterialsuchasScotch23Tapewide,from3Mto
ensureIP67compliantprotectionagainstwateranddust.
2.Cuttwopieceseach25cmlong,ofScotch23splicingtape.Removetheplasticcover
toexposethetackysideofthesealingtapeasshowninFigure 437.

Figure437:Exposingthetackysideofthesealingtape
3.AfterconnectingtheshortCAT5eIDU/ODUcable(providedinthebox)fromthe
ODUtotheunit,tightenthecableglandcapfirmlyandusetheinsulationtape
scotch23tofullycoverbothofthecableglands.
4.ConnectthetapewithtackysideuponthecableglandcapandtheCAT5ecable.
StartatStartPointatthebottomofthecableglandasshowninFigure 438.Finish
atEndPointoftheCAT5ecable,2.5cmaftertheendoftheshrinktubing.Stretch
thetapeandapplyhalfoverlappedtoformgapfreejoint.

RADWIN5000HPMPUserManual

Release3.5.50

425

InstallingtheBaseStation

Figure438:StartandEndpointsforprotectivetapingtheunit
5.Wraptwolayersofanyscotchvinylplasticelectricaltype(e.gScotchSuper88Vinyl
PlasticTapefrom3M)toprotectthejointsasshowninFigure 439.Ensurethatthe
bottomofthecableglandandtheendoftheCAT5ecablearecoveredwiththe
sealingsplicingtapeandwithvinylplastictape.

Figure439:Protectingtheunitjointswithvinyltape
6.MounttheunitonthepoleusingthemountingringasshowninFigure 440.Ground
theunitusingtheGNDscrew.Forlightningprotection,repeatthesameprocedureto
installthesecondunitconnectedtotheIDU.
RADWIN5000HPMPUserManual

Release3.5.50

426

TheIDUH:ABaseStationAlternativetoPoEDevices

Figure440:Mountedandstrappedtothepole
ExternalPortsforCAT5eCables
AllexternalHBSportsshouldbewatersealed.Usethesamematerialsandmethodasforthe
LPUcableglands.

TheIDUH:ABaseStationAlternativetoPoEDevices
UsinganIDUHinsteadofseveralPoEdevices
TheIDUHisanaggregationswitchwiththefunctionalityofsixPoEdevices.Itisidealforuse
atabasestationhavingseveralcollocatedHSUsorRADWIN2000radios.

Figure441:IDUH

InstallinganIDUH
TheIDUHcansitonatabletop,butisbestinstalledinarackusingthesuppliedearsasin
Figure 412andFigure 413.

ConnectingtheHBStoanIDUH
ConnecttheHBSIDUporttoanyofthesixPoEportsoftheIDUH.

ConnectingtheIDUHdevicetoanetwork
TheIDUHhastwoLANports,eitherofwhichmaybeusedfornetworkconnection.

RADWIN5000HPMPUserManual

Release3.5.50

427

TheIDUH:ABaseStationAlternativetoPoEDevices

GroundingandPoweringUptheIDUH
TheIDUHhasredundantpowerconnectioncircuits.Anenlargedviewofthepower
connectorsisshowninbelow:

Figure442:IDUHpowerconnectors,groundinglugandpowerplug.

FordirectDCconnection:Theconnectorsare3pininlinefemale,withpolarities(leftto
right)minus,ground,plus.
ForACconnection:ToavoiddamagetotheIDUH,alwaysuseanAC/DCadapterand
powerplugsuppliedbyRADWIN.

Groundtheunitwitha10AWGwirebeforeapplyingpower.

Warning
IDUHFunctionalOverview

Figure443:IDUHfrontpanel
Thefrontpanelisverystraightforward:TheSFPportsarestandard.TheLANportsare
EthernetandsupportGbE.ThesixODUWANportsfunctionidenticallytotheLANOutport
onaPoEdevice.

RADWIN5000HPMPUserManual

Release3.5.50

428

InstallingFixedSubscriberUnits

TheIDUHLEDs
Table43:IDUHLEDIndicators
Port

Green

Yellow

WAN(2xRJ45LEDs)

Link/Activity

DuplexorPortsPoEstatus(configurable)

LAN(2xRJ45LEDs)

Link/Activity

Duplex

SFP(2panelmountedLEDs)

Link/Activity

Duplex

InstallingFixedSubscriberUnits
Sitesurvey
ThesameconsiderationsasforanHBSholdfortheHSUs.

Sitepreparation
ThesameconsiderationsasforanHBSholdfortheHSUs.

MountingtheHSU
StandardformfactorHSUsaremountedinexactlythesamewayasanHBS.Smallformfactor
HSUsaredifferent:
AsmallformfactorHSUmountingkithasamountingkitadapterandtwometalties:

Figure444:SmallformfactorHSURear,metaltie
Themountingtiesarethreadedthroughthemountingslotsprovidedandtheunitmounted
onapole.

RADWIN5000HPMPUserManual

Release3.5.50

429

InstallingFixedSubscriberUnits

Figure445:Mountingadapter
Table44:MountingadapterkitforsmallformfactorHSUs
Item
Description
No.

Qty

Metalties

Mountingadapter

ScrewM5x10,CSK,Phillips,
stainlesssteel

ThemountingadapterisusedwiththestandardmountingkitshowninFigure 423.Itisnot
includedintheHSUpackageandmustbeorderedseparately.

TomountthesmallformfactorHSUusingamountingkit:
1.ReferringtoFigure 446below:Securetheadapter(3)totherearoftheHSU(2)
usingthetwoscrewsprovided(4).UseaPhillipsscrewdriversettoatorqueof2.0
NM.

Figure446:Securingthemountingadapter
2.ReferringtoFigure 447below:AttachtheODUmountingkit(1)tothemounting
adapterear(4)andproceedasabove,forastandardODU.

RADWIN5000HPMPUserManual

Release3.5.50

430

InstallingFixedSubscriberUnits

Figure447:Attachingastandardmountingkit

Note

WhenmountinganHSUonapoleorwall,ensurethattheunitisori
entedsothatthecableconnectorsareatthebottom.
DonotmountanHSUhorizontally
ForanHSUwithanintegratedantenna:DonottightentheHSUtoits
mountingbracketuntiltheantennaalignmentprocessiscomplete.
EnsurethattherearenodirectobstructionsinfrontoftheHSUor
interferencefrommanmadeobstacles.

MountinganHSUexternalantenna
ManyoftheantennasofthetypesshowninFigure 415toFigure 417usethestandard
mountingkitofFigure 423.Somethirdpartyantennasusepoleclamps,similartothose
shownbelow:

Figure448:Poleclampsforexternalantennas

Donotstandinfrontofaliveantenna.

Warning

RADWIN5000HPMPUserManual

Release3.5.50

431

InstallingFixedSubscriberUnits

GroundinganHSUexternalantenna
ExternalantennasshouldbeindividuallygroundedusingasuitableGroundingKitsuchasan
AndrewType2231582(http://www.commscope.com).Thesameconsiderationsasforthe
HBSantennasapplyhere.

GroundingtheHSU
AllHSUshaveagroundinglugasshowninFigure 449.Connectittogroundusing10AWG
wire.Groundingisoftencarriedoutinconjunctionwithlightningprotection.

Figure449:HSU:Groundinglugstandardandsmallformfactor

UsingACPoweredHSUs
TheACHSUhasanintegratedflatpanelantenna.IthasadirectACpowerinlet,aLANport
andaPoEoutporttoconnecttoapowereddevicesuchasavideocamera.

Figure450:SmallformfactorHSUwithACpowerfeeding
ItismountedandgroundedlikeanyothersmallformfactorHSU.

InstallingaPoEdevice
ThesameconsiderationsasforanHBSholdfortheHSUs.

ConnectingtheHSUtotheNetwork
ThesameconsiderationsasforanHBSholdfortheHSUs.

RADWIN5000HPMPUserManual

Release3.5.50

432

InstallingFixedSubscriberUnits

PoweringuptheHSUfromaPoEdevice
ThesameconsiderationsasforanHBSholdfortheHSUs.

EstablishingaRadioLinkAligningHSUstoaHBS
UsetheHSUsbuzzertoperformHSUantennaalignmenttoaHBS.

ToalignanHSUtoitsHBS:
1.EnsurethatthesectorantennaoftheHBSisalignedpreciselytothesectoritis
intendedtocover.Useacompassandtopographicalmapstodothis.
2.ForboththeHBSandHSUs:UsingacoaxcablewithNTypeconnectors,connectthe
verticalpolarizationconnectoroftheantennatotheANT1connectoroftheODU.
Then,usingasecondcoaxcablewithNTypeconnectors,connectthehorizontal
polarizationconnectoroftheantennatotheANT2connectoroftheODU.

Note

ThereisnoparticularreasontouseANT1andANT2inthatorder:Theyjust
havetobethesameforeachODUinthesector.Further,adoptinga
conventionlikeANT1isalwaysverticalavoidsmistakesacrossalarge
sector.

3.EnsurethatpowerisconnectedtothesitePoEsacrossthesector.
AnunalignedHSUstartsbeeping20secondsafterpowerup,andcontinuesbeeping
untilitisalignedtotheHBS.
Thealignmentdetailsaredescribedinthenexttwosteps.Antennarefersbothto
anexternalantennaandanintegratedantenna.Thetwostepsshouldbecarriedout
foreachHSUinthesector.
4.Makeahorizontalsweepof180degreeswiththeHSUantennasothatthestrongest
signalfromtheHBScanbedetected.
5.SlowlyturntheHSUantennabacktowardsthepositionoftheHBS,listeningtothe
toneuntilthebestsignalisreached.Seethefollowingfigureforaudiblesignal
variations.

Figure451:BeepSequenceforantennaalignment

RADWIN5000HPMPUserManual

Release3.5.50

433

InstallingaVehicularMobileUnit

Note

Threebeepsandapauseis'bestsignalsofar'
Twobeepsandapauseis'signalqualityincreased'
Onebeepandpauseis'nochangeinsignal'
Longbeepandshortpauseis'signalqualitydecreased'
Onebeepandalongpauseis'noairlink'
Anyothersignaldoesnotrelatetoantennaalignment

6.SecuretheHSUantennatothepole/wall.

Note

TheHSUbeepingwillstopcompletelywhenitisconfiguredusingthe
RADWINManager.Itmayalsobeunconditionallyswitchedofffromthe
Manager.

Connectinguserequipment
Typicaluserequipmentincludesswitchesandvideocameras.Beforeconnectinguser
equipmenttotheHSUthroughtheLANInportofthePoEdevice,ensurethatitpowered
down.IfyouareusinganACHSU,youmayusethePoEOutporttoconnectandpowera
videocamera.Followyourcameramanufacturersinstructionsscrupulouslytoavoiddamage
toyourequipment.

Mountinglightningprotectiondevices
ThesameconsiderationsasforanHBSholdfortheHSUs.

Additionalconsiderationforwaterproofing
LightningProtectorsandEthernetRepeaters
ThesameconsiderationsasforanHBSholdfortheHSUs.
ExternalPortsforCAT5eCables
ThesameconsiderationsasforanHBSholdfortheHSUs.
HSUACPowerports
Theyshouldalsowewaterproofedinthesamemannerastheotherports.

InstallingaVehicularMobileUnit
ScopeofthisSection
TheVMUcanbeinstalledintoalmostanygroundvehicle.Tokeepthissectionasrealisticas
possible,weuseasourexample,installationintoaprivateautomobile.Inourview,thiscan
bethemostdifficultandchallengingsituation,duetothelimitedspaceintypicalcompact
privatevehicles.

RADWIN5000HPMPUserManual

Release3.5.50

434

UnpackingtheVMU

UnpackingtheVMU
VMUKitContents

VMUradio

Figure452:VMUradio

1xPowercable7mwithfemale5pinM12connectorandlabelperwire

2xFusesforpowerandignition

Figure453:Inlinewaterprooffuseholderfor14AWG/20Aand12AWG/30Awiring

1xLANcable7mwithfemaleM12connectorandRJ45connector
Installationkit,including:
Mechanicalelementforcablesprotectionandunitdeployment
2xFerules
4xM5Screws
4xM12caps(Silicon,attachedtotheunit)
5xSMAcaps(Silicon,attachedtotheunit)
1xQuickInstallationGuide(pamphlet)

RADWIN5000HPMPUserManual

Release3.5.50

435

UnpackingtheVMU

InstallationSchematic

Figure454:VMUinstallationschematic
PowerwiringisshowninFigure 457below.

Antenna

Figure455:TypicalcompositeSharkFinantenna,forradiobroadband,WiFiandGPS
Twomultipurposesharkfinantennasaremountedontherearofthevehicleroofabouta
meterapart.Theyshouldbeorderedseparately.

RADWIN5000HPMPUserManual

Release3.5.50

436

MotorVehiclePowerSupply

Figure456:MountedtwinSharkFinantennas

MotorVehiclePowerSupply
TheVMUworkswith1036VDCpower.Itmaybeinstalledwithoutspecialprovisionsin
ordinarymotorvehiclesusinga12Vpowerorinheavyvehiclesusing24Vpower.

Figure457:VMUpowerwiringschematic

RADWIN5000HPMPUserManual

Release3.5.50

437

InstallationProcedure

InstallationProcedure
ForM12connectors,usealockingtorqueof0.49Nm.

Note

UnpackingandChecking

Foreachoftheitemsbelow,dothefollowing:
1.Removetheequipmentfromthebox.
2.CheckthateverythinglistedontheincludedBillofMaterialsorProformaInvoiceis
present.
3.Ifanyitemismissing,contactCustomerService.Youwillbeadvisedwhetherto
returnthepackageforreplacement,orwhetherthemissingitemcanbesupplied
separately.
4.Donotdisposeofthepackaginguntiltheunitisinstalledandoperational.

ToolsandAdditionalMaterials

Spanner/wrench,screwdriversvarious(primarilyforsmallelectricalconnections)
Drill
SealingmaterialorotherwaterproofingtapesuchasScotch23Tapewide,from3M
toensureprotectionagainstwateranddustforcableentryintothevehicle.

Installation
MounttheVMUinasafeprotectedlocation.Theambienttemperatureshouldbeinthe
range35Cto+60C(31Fto+140F).

TopreparethevehicleforVMUinstallation:
1.LocateandmarktheVMUintheplacewhereyouwanttomountit.
2.Determinethepreciselocationoftheantennasontherooftop.
3.RoutethecablesfromthevehiclebatteryareatotheVMUlocation.
4.RoutethecablesfromtheantennalocationtotheVMUlocation.
5.RoutethecablesfromthecabinPC/CameratotheVMUlocation.

TophysicallymounttheVMU:
1.Placetheunitagainstthesurfacetowhichitistobemounted.
2.Markthescrewplacementsusingfourofthemountingholesintheunitasguides.
3.Drillholesinthesurfaceusingyourmarks.

RADWIN5000HPMPUserManual

Release3.5.50

438

Installation

4.Iftheunitismounteddirectlytothecarchassis,usesheetmetalscrewsandstar
washers.
5.Iftheunitismountedonanonmetallicsurface,suchasplasticorwood,usesuitable
screwsorbands.
6.Fastenthescrewstosecuretheunitfirmlyinplace.
7.ConnectalltheinterfacestotheVMU.Powershouldbeconnectedlast!

RADWIN5000HPMPUserManual

Release3.5.50

439

Part2:SectorInstallation

Release3.5.50

Chapter5:

GettingStartedwiththe
RADWINManager
Whatwewilldohere
Thischapterisaquickhandsontourofarunningsector.Weshowyouhowtoinstallthe
RADWINManagersoftwareonyourmanagingPC,connectittoanoperatingbasestationand
thenlogon.WethenexplaintheuseofthevariousobjectsontheRADWINManagermain
window.
Thebackgroundacquiredherewillenableyoutounderstandthedirectionandpurposeof
thedetailedprocedures(describedinlaterchapters),requiredtobuildaRADWIN5000sector
fromthegroundup.

InstallingtheRADWINManagerApplication
MinimumSystemRequirements
TheRADWINManagerapplicationisdistributedonaCD.OperatingsystemspecificPC
resourcesrequiredbytheapplicationaresetoutinTable 51below:
Table51:PCRequirementsfortheRADWINManagerApplication
WindowsVersion
XPPro
Memory

512Mb

Processor

PIV

Vista/7/8
32bit

1Gb

64bit

2Gb
PIVDualCore

Requirementscommontoallsystemsare:
RADWIN5000HPMPUserManual

Release3.5.50

51

InstallingtheSoftware

Harddisk:1GBfreespace
Network:10/100BaseTNIC
Graphics:1024x768screenresolutionwith16bitcolor
AnymodernWebbrowsertoviewadditionalmaterial,usetheWebInterfaceorget
helpfromtheRADWINWebsite.

InstallingtheSoftware
AnyPCrunningtheRADWINManagerapplicationcanbeusedtoconfigureaRADWIN5000
HPMPsector.

ToinstalltheRADWINManagerapplication:
1.InserttheCDintotheCD/DVDdriveofyourcomputer.
2.TheCDopeningwindowappears:

3.ChooseInstallRADWINManagerandfollowtheonscreeninstructionsofthe
installationwizardtocompletethesetupoftheRADWINManagerapplication.
Iftheinstallationprogramfailstostart,browsetoyourCD/DVDdrive,chosethe
setup.exeprogramandrunit.

RADWIN5000HPMPUserManual

Release3.5.50

52

GettingStartedwiththeRADWINManager

GettingStartedwiththeRADWINManager
We will look at a preconfigured fixed sector, setup as follows:

Table52:PreconfiguredsetupHBS
Location

Attribute

IPv4

IPv6

Value

Address

10.104.50.200

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::200

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSinthesame
subnet

SectorID

EBGX20560334

InheritedbyallcommunicatingfixedHSUs.

NetworkID

EBX

Inheritedbyallcommunicatingnomadic

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1andv3

Contact

Bach

Optional

Name

Bach@HBS.01

LocationofContactoptional

Band

5.7305.845GHzFCC/IC

InheritedbyallcommunicatingHSUs

ChannelBandwidth

20MHz

InheritedbyallcommunicatingHSUs

UnitSerialNumber

PET540E000A00000

HBS.01

Geographiclocation
Latitude

37.8148

Longitude

144.9630

Azimuth(deg)

Beamwidth(deg)

90

Antennaheight(m)

130

UsedforinitialdefaultplacementofHSUs

RADWIN5000HPMPUserManual

Release3.5.50

FromRFplan,notused

53

GettingStartedwiththeRADWINManager

Table53:PreconfiguredsetupHSUs
Location

Attribute

IPv4

IPv6

Value

Address

10.104.50.1

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::1

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSin
thesamesubnet

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Haydn

Optional

Name

Haydn@HFU.01.01

LocationofContactoptional

HFU.01.01
Downlink

Uplink

TimeSlots

Mayvarywithcontext

UnitSerialNumber

P07030E000A0003E

Geographiclocation
Latitude

37.89651

Longitude

145.15716

Antennaheight(m)

10

IPv4

IPv6

Address

10.104.50.2

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::2

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

FromRFplan,notused

AllcommunicatingHSUsandHBSin
thesamesubnet

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Mozart

Optional

Name

Mozart@HFU.01.02

LocationofContactoptional

HFU.01.02
Downlink

Uplink

TimeSlots
UnitSerialNumber

Mayvarywithcontext
P07030E000A000422

Geographiclocation
Latitude

37.62400

Longitude

145.21484

Antennaheight(m)

60

RADWIN5000HPMPUserManual

Release3.5.50

FromRFplan,notused

54

GettingStartedwiththeRADWINManager

Table53:PreconfiguredsetupHSUs(Continued)
Location

Attribute

IPv4

IPv6

HFU.01.04
(Usedonlyto
illustrateAES
265)

Value

Address

10.104.50.4

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::4

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSin
thesamesubnet

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Handel

Optional

Name

Handel@HFU.01.04

LocationofContactoptional

Downlink

Uplink

TimeSlots

Mayvarywithcontext

UnitSerialNumber

P07030E000A0003B

SupportsAES256

Geographiclocation
Latitude

37.4018

Longitude

145.0086

Antennaheight(m)

60

FromRFplan,notused

Table54:PreconfiguredsetupLevelallocationformaximumnomadicHSUs
Level

Numberof
nomadicHSUs

TimeSots
Downlink

Uplink

RADWIN5000HPMPUserManual

Release3.5.50

Remark
IncludesHNU.0.01below

55

GettingStartedwiththeRADWINManager

Table55:Preconfigured setup - one nomadic HSU


Location

Attribute

IPv4

IPv6

Value

Address

10.104.50.3

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::3

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSin
thesamesubnet

HNU.01.01
Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Brahms

Optional

Name

Brahms@HNU.01.01

LocationofContactoptional

Downlink

Uplink

TimeSlots
UnitSerialNumber

Mayvarywithcontext
P07030E000A0003B

WehaveaddplaceholdersforafurtherthreenomadicHSUs.Thatis,uptofourvehicles
equippedtoworkinthisway,mayoperatesimultaneouslyinthesector.

Tip

Chooseyourunitlocationscarefully.Forexample,forthreecollocatedHBSs
eachwith32HSUscovering360,mattersgetoutofhandveryquicklyif
unitsarepoorlynamed.TheycanalwaysbeidentifiedbytheirIPaddresses,
butthatisapoorsubstituteforeffectivenaming.AURLlikenamingpattern
basedonHBS_n.HSU_yisclearandfamiliartoallInternetusers.Keeping
thenamesIPaddressindependentenablesyoutocopytheentiresector
setuptoadifferentgeographiclocationwithoutIPaddressduplication.
TostarttheRADWINManager:
1.ConnectthemanagingcomputertotheHBSPoELANport.
2.CheckthatyouhaveconnectivitytotheHBS.Youcandothisbyopeningupa
commandlinesession(Start|Runandthentype,cmd).Atthecommandprompt,
type
ping10.104.50.200
Youshouldseesomethinglikethis:

RADWIN5000HPMPUserManual

Release3.5.50

56

GettingStartedwiththeRADWINManager

Figure51:Pingingthebasestation.
UnderIPv6.thepingwilllooklikethis:
ping2005:104:50::200

Figure52:PingingthebasestationIPv6
AnyotherresponsefrompingmeansthattheHBSODUisnotresponding.Check
yourEthernetconnectionandthatboththePoEandODUareswitchedonandthen
tryagain.Ifyoudonotsucceed,seekassistancefromRADWINCustomerService.
PingingtheHSUsshouldyieldsimilarresponses.
3.Dismissthecommandlinesession.
4.OpentheRADWINManagerfromthedesktopicon,orclickStart|Programs|RADWIN
Manager|RADWINManager.
TheLogondialogboxappears.

RADWIN5000HPMPUserManual

Release3.5.50

57

TheRADWINManagerLogonConcept

Figure53:LogonwindowIPv4

Figure54:LogonwindowIPv6

TheRADWINManagerLogonConcept
RADWIN5000supportsSNMPv1andSNMPv3eitherseparatelyortogether.Thelogon
procedurediffersslightlybetweenoperationunderSNMPv1andSNMPv3.Inwhatfollows
below,weassumethatSNMPv1isinuse.InTable 56atendofthesection,weshowthe
differencebetweenSNMPv1andSNMPv3atlogontime.
TheRADWINManagerprovidesthreelevelsofaccessinoneoftwoentrymodes.Tosee
them,clickOptionsatanytimeintheLogonwindow(Figure 53above).Youareofferedan
extendedlogonwindow:

RADWIN5000HPMPUserManual

Release3.5.50

58

TheRADWINManagerLogonConcept

Figure55:Extendedlogonwindow
AttheUserTypefield,clickthelistbutton:

Figure56:Logonwindowexposingtheusertypes.
Therearethreeusertypes:

AnObserverhasreadonlyaccesstothesector.AnObservercanmonitorthesector,
generatereports,butmaynotchangeanysectorparameters.
AnOperatorcaninstallandconfigurethesector.
AnInstallercan,inadditiontofunctioningasanOperator,alsochangetheoperating
frequencyband(orregulation).Thelatterfunctionhaslegalramifications,requiring
familiaritywithlocalregulations.

TosettheSNMPversion,usetheSettingsbuttoninFigure 55.Alogonextensionwindow
opens:

RADWIN5000HPMPUserManual

Release3.5.50

59

TheRADWINManagerLogonConcept

Figure57:LogonwindowshowingSNMPsettings.
YoumaychoosetheSNMPversion.IfyourfirewallblocksSNMPv3messagesandforsecurity
reasonscannotbechangedthemuseSNMPv1.
IfyouareusingTrapAuthentication,entertheUserandPassword.Leavingthesefieldsblank
orincorrect,willnotpreventyoufromloggingon.Youwillnotbeabletoseetrapmessages
directedtothetrapmessageaddressassociatedwithadefineduser.Theallocationand
associationofatrapaddresswithauserisdescribedinChapter8,Management.
IfyouareconnectingthroughtheRNMSserverchecktheRMNSconnectbuttonandenter
yourserverIPaddress.
Thefollowingtablesummarizestheseoptions:
Table56:Usertypes,defaultpasswordsandfunction
SNMPv1
UserType

Default
Password

Function

Observer

admin

Operator
Installer

SNMPv3

Community

Communi
tyString

Password

Default
Value

Monitoring

ReadOnly

public

ReadOnly

public

admin

Installation,
configuration

ReadWrite

netman

ReadWrite

netman

wireless

Operatorplus
ReadWrite
setband

netman

ReadWrite

netman

RADWIN5000HPMPUserManual

Release3.5.50

510

LogonErrorsandCautions

TheNetworkManagershouldchangethedefaultpasswordsassoonaspossible,particularly
ifSNMPv3istobeused.

Continuingthelogonprocedure:
5.IfyourUserTypeisnotOperator,thenchooseitnow.
6.Enterthepassword.
7.IfyouareauserwithReadWritepermission,clickOptionstoentertheCommunity
optionsifrequired.

Note

LeavethedefaultCommunitypasswords,netmanforreadwrite,and
publicforreadonly.
Ifyouareauserwithreadonlypermission,thenyoumayonlylogon
asObserver.

LogonErrorsandCautions
UnsupportedDevice
AttemptingtoconnecttoanunsupporteddeviceonanotherwisevalidIPaddress(for
example,aLANprinter)willresultinthefollowingerrormessage:

Figure58:Unsupporteddevicemessage

IncorrectIPAddress
IftheIPaddresschosenisinvalidorthesectorisunreachable,thefollowingerrormessage
willbedisplayed:

RADWIN5000HPMPUserManual

Release3.5.50

511

IncorrectPassword

Figure59:Unreachabledevicemessage

IncorrectPassword
IfyoutypeanincorrectpasswordintheLoginwindow,thefollowingmessagewillbe
displayed:

Figure510:Invalidusertypeorpassword

InvalidRead/WriteCommunityStringorSNMPv3Passwords
ThiswillresultinthesamemessageasshowninFigure 59.

TodealwithlostorforgottenCommunityStrings:
1.SendanemailrequestfortoRADWINCustomerServiceforanalternativekey.Your
emailmustincludetheODUserialnumbershownontheadhesivestickeronrearof
oneofyourODUs.
2.Thereplywillcontainanalternativekey,whichfunctionsasatemporarymaster
CommunityString.Copy/pastethesuppliedalternativekeytoboththeReadOnly
andReadWritefieldsinthelogonwindow(Figure 55).Thisgetsyoutothe
RADWINManagermainwindow.
3.Usetheprocedureonpage 819toenternewCommunityStrings.

RADWIN5000HPMPUserManual

Release3.5.50

512

FourSectorDisplayViews

FourSectorDisplayViews
TableView
TheRADWINManageroffersthreesectordisplayviews.Thedefaultviewforafreshly
installedsectorisTableviewandlookslikethis:

Figure511:DefaultSectordisplayTableview

RADWIN5000HPMPUserManual

Release3.5.50

513

TableView

WhatsontheCardsTableView
TheindividualHSUdisplayboxesarecalledcards.Theyareusedwithsmallvariationsinthe
TableandMapviews.

fixedHSU

nomadicHSU

nomadicHSUplaceholder

Figure512:HSUCards
ThecardtitlebarholdsasmuchoftheHSUnameasfits.

TheIP(address)andLoc(ation)areasdefinedbyyouduringConfigurationorRegistra
tion
TheRSSfortheHSUandHBSareshownasbargraphsforconvenience.Theyshouldbe
balanced.IfforoneHSUthereisaconsistentimbalanceofeven1dBMorintermittent
imbalancesof23dBmyoushouldcheckitsantennaconnectionsandperhapstheunit
itself.IfseveralHSUsareoutofbalance,theremaybeaproblemwiththeHBS.
TheLevelinthenomadicHSU:Therearefourallowedlevels(AtoD)allowingameasure
ofprioritizationofnomadicHSUs.Wewillseehowthisisdoneonpage 632.
DownlinkandUplinkthroughput:ThegreenpartofeachbarshowstheAssured
throughputbasedonthenumberoftimeslotsallocatedtotheHSUsubjecttothecur
rentsectortrafficload.ThelightbluebarshowthePeakthroughput,againsubjectto
trafficconditions.Thepeakthroughputmayexceedtheassuredthroughputduetothe
operationofSmartBandwidthManagement(SBM),discussedindetailinChapter10.
TheRxandTxratesatthebottomofthecardaretheEthernetreceiveandtransmit
ratesfortheHSU.AnextendedviewshowingtheTxandTxratesforthetwoantenna
chainsinalsoavailable:

RADWIN5000HPMPUserManual

Release3.5.50

514

MapView

SeeSettingRADWINManagerPreferences,Advancedbelow.
Thelittleballonthetopleftofeachcardisastatuslight,whichwillbeexplainedin
Table 511below.

MapView
IfyouhaveanInternetconnection,youmayuseMapview.Themapviewusesdistinctive
iconstodistinguishbetweendifferenttypesofHSUsandtheHBS:

HBS

fixedHSU

nomadicHSU

HMU/VMU

Figure513:Mapviewicons
Thegreenbeaconlightontopoftheiconschangescoloraccordingtotheunitsstatus.The
colorcodesaredefinedinTable 511below.
ThedefaultRADWINManagermainwindowlookslikethis:

RADWIN5000HPMPUserManual

Release3.5.50

515

MapView

Figure514:SectordisplayDefaultMapview
Anewsectorwithdefaultvaluesforelementmapcoordinatesisshowncentredon
Greenwich(Figure 514).ThesectoriscenteredontheHBSazimuth(configurable).TheHSUs
distributedevenlywithinthesectorbeamwidth(configurable)withoutregardforgeographic
considerations.
IfyoudonothaveanInternetconnection,thedisplaybackgroundwillbesolidgray.
Forthisdemonstration,weuseasectorcenteredonMelbourne,Australia.Thelocationof
theHBSandtwofixedHSUsisbasedonaRadioPlanshowninTable 57.
ThenomadicHSUs,havingnopredefinedcoordinatesaredistributedevenlyacrossthesector.
LaterweshowyouhowtochangethepositionsoftheHSUiconsonthemap.

RADWIN5000HPMPUserManual

Release3.5.50

516

ListView

ListView
TheListviewlookslikethis:

Figure515:SectordisplayListview
AtthebottomoftheHSUdisplaypanel,thereisathinhorizontalscrollbar.Useittosee
furtherdetailsaboutthedisplayedHSUs.TheIndexandNamefieldsareprotectedsoyou
alwaysknowtowhichHSUsthedatabelongs.Thestatusindicatorballhasthesamemeaning
asitdoesfortheHSUcardsandmapicons.Fordetails,seeTable 511below.
Youmayrestrictthedisplayedfieldstothoseofinterest.Ifyourightclickanywhereinthelist
youareofferedaSelectColumnsbutton:

Clickingitopenthefiledchoicemenu:

RADWIN5000HPMPUserManual

Release3.5.50

517

ListView

Thegrayedoutitemsarealwaysdisplayed.Theothercheckeditemsareshownbydefault,
butmayberemoved.

RADWIN5000HPMPUserManual

Release3.5.50

518

UtilizationView

UtilizationView
TheUtilizationviewshowshowsectorresourcesareallocatedbetweenHSUs.Itisparticularly
importantsincetheSBMmechanismcantemporarilyassignunuseddownlinktimeslotstoa
verybusyHSU.Itcanalsotemporarilyassignunallocateduplinktimeslotsforthesame
purpose.

Figure516:DefaultSectordisplayUtilizationview
TheelementsoftheUtilizationviewareexplainedindetailinChapter10whereSBMis
discussed.

RADWIN5000HPMPUserManual

Release3.5.50

519

SwitchingBetweenViews

SwitchingBetweenViews

Toswitchbetweendisplays:

Clicktherelevant
tab.Fromlefttoright,thetabsare,
Mapview,Tableview,ListviewandUtilizationview.Theactivetab(Tableviewinthe
illustration)isshownenlarged.

DisplayViewPersistence
ThelastdisplayviewusedwillbethatopenedatyournextrestartorlogontotheRADWIN
Manager.

WhichDisplayViewShouldIUse?
Yourpreferredviewisclearlyapplicationdependent.Forageographicallylocalizedsector
say,videosurveillanceofaplantorasportscenterwithasmallnumberofcameras,Tableor
Listviewmightbeadequate.Ourownexampleisbasedonabackhaulsituationforwhichthe
Mapsviewisveryhelpful.

ContinuingwithourExampleSector
UsingtheMapView
Tosetupanewsectorortocarryoutsubstantialchangestoanexistingsector,youshould
haveaRadioPlanfromyourSiteSurvey.Theminimumrequirementisalistoflocationsand
theircoordinates.HereisourplanextractedfromTable 52:
Table57:RadioPlanforasmallsector
UnitType

SiteName

Latitude

Longitude

Antenna
height(m)

fixedHSU

Mozart@HFU.01.02

37.4018

145.0086

60

fixedHSU

Haydn@HFU.01.01

37.8762

145.0437

10

nomadicHSU

Brahms@HNU.01.03

n/a

n/a

n/a

HBS

Bach@HBS.01

37.8148

144.9630

130

Note

Aplanofthistypemaybepreparedbyhand,orbyusingasuitableRadio
Planningtool.Themethodusedhereallowedustospecifyantennaheight
aswellsoastoguaranteeLOS.Whileitisnotofdirectuseinwhatfollows,
antennaheightisrequiredtocarryoutphysicalinstallationassetoutin
Chapter4.

RADWIN5000HPMPUserManual

Release3.5.50

520

UsingtheMapView

TorelocateaHBSorHSUbysettinglatitudeandlongitudecoordinates:
1.RightclicktheHBS(Bach@HBS.01)toopenitsContextmenuandthenConfigure.
2.ClicktheCoordinatesbuttontoopentheCoordinateswindowandentertherequired
latitudeandlongitude.

Youmayenterthecoordinatesindecimalordegrees/minutes/secondsusingthe
inputtemplateshownbelow:

3.HBSonly:TheAzimuthandBeamWidthdeterminethesectorcenterlinedirection
andangleTheyareonlyusedforinitialdefaultdistributionofHSUsonthemap.
4.ClickOK.Theunitismovedtothenewlocation(possiblyoffscreen).
5.RepeatthepreviousfourstepsforeachHSUinthesector.Ifattheendoftheprocess,
theHBSisoffscreen,clicktheCenteronSectorbuttontoflytothesector.

UsingtheexampleinTable 57,hereistheoutcome:

RADWIN5000HPMPUserManual

Release3.5.50

521

UsingtheMapView

WehavelocatedtheentiresectortoMelbourne,Australiainaccordancewithour
RadioPlan.Thegreylinesandiconsarepreregisteredplaceholdersforadditional
nomadicHSUs.
YoucanmakemanuallocationadjustmentsusingtheGUI.

TorelocateaHBSorHSUusingtheGUI:
1.Selecttheunittomovebyclickingit.Itissurroundedbyabrownbox.
2.Mouseoverthetopedgeoftheboxtogetacontextbuttonbarasshownin.

Figure517:SelectedHBSorHSUwithcontextbuttonbar
Thefunctionsofthreebuttons(fromlefttoright)areasfollows:

RADWIN5000HPMPUserManual

Release3.5.50

522

UsingtheMapView

Table58:UnitContextButtonbarfunctions
Button

Tooltip

Purpose

Left

Show/Hidedetails

Show/Hidethestatuswindow

Center

Unlock/LockItem

Unlocktodragonmap,locktosecureposition

Right

Zoomin

Showmorebackgrounddetail.Alsodisplaysthe
unitstatuswindowifnotalreadyvisiblea

a. Youcanalsozoomin/outusingthemousescrollwheelinthestandardway
Theleftdetailsbuttonopensacard,similartothoseinFigure 512:.

HBS

fixedHSU

nomadicHSU

placeholderforanomadic
HSU

Figure518:MapCards
UnliketheTableViewcards,thestatusindicatorisontheiconitself.
3.ClicktheUnlockbutton.Dragthetowericontoitsnewlocation.Youmustconfirm
thechange:

RADWIN5000HPMPUserManual

Release3.5.50

523

ExploringtheRADWINManagerMainWindowHBS

Thechangeisthencarriedout.

Note

Theforegoingchangeconfirmationisimportant:Thereisnoundo
function.Ifyouinadvertentlymovetheunittoawrongplace,youwillhave
torestoreitspositionbyhand.

ExploringtheRADWINManagerMainWindow
HBS
ThefollowingsectionsdescribethepanelsofmainwindowshowninFigure 511.

HBSMainButtonMenu

Figure519:HBSmainbuttonmenu
Table59:HBSmainbuttonbarfunctions
MenuItem

Preferences

Purpose

CrossReference

MonitorFilelocation,intervalandthroughputunits

Monitor

EventsColorcodingforeventslogandeventslogfile
location

Events

AdvancedEnable/disablecheckforupdates,Monitoring
Advanced
intervalandtimeout,mapviewbackgroundmode
Software
Upgrade

Performsoftwareupgradeforasector

Upgradingan
InstalledSector

SWUside
arrow

BulkbackupofHBSandHSUsoftware

BulkSoftware
Backup

Get
Diagnostics

Runandstorediagnosticsforallorsomemembersofa
sector

Monitoringand
Diagnostics

LogOff

Returntologonwindow

Helpside
arrow

LinkBudgetCalculator

LinkBudget
Calculator

CheckUpdates
About
HelpButton

ViewthisUserManual

RADWIN5000HPMPUserManual

Release3.5.50

524

SectorStatusPanel

SectorStatusPanel
Thesectorlevelinformationisshownhere.Thereisnothingthatcanbechangedforanactive
sector.Theparametersaresetbeforethebasestationisactivatedandareduplicatedforeach
HSUinthesector.

Figure520:SectorStatuspanel
Thelasttwoitemsareofspecialinterest:TheStatus(shownasActive)indicateswhetherthe
HBShasbeenactivatedornot.TheTimeSlotsbarsindicatehowmanyoutof63timeslotsin
uplinkanddownlinkdirections,havebeenallocatedtoHSUs.Allocationoftimeslots
betweenHSUsprovidesabasicformofprioritizationbetweenthem.Normallyyouwouldnot
leaveunallocatedtimeslotsunlessyouintendedtoaddmoreHSUs.EveryHSUrequiresat
leastonetimeslot.TimeslotallocationiscloselyrelatedtoSBMperformancedetailedin
Chapter10.

BaseStationPanel
ThedisplayeditemsintheBaseStationpanelarestraightforward.

Figure521:BaseStationdetailPanel
TheTxRatioshowstheallocationofthroughputbetweendownlinkanduplinktrafficatthe
HBS.Hereitissetto70%downlinkand30%uplink.TheTxRatioisnotonlysectorwide:If
youuseHSS(Chapter13Chapter15)tocollocatedseveralHBSs(tocoveradjacentsectors),
theymustallusethesameTxRatio.
RADWIN5000HPMPUserManual

Release3.5.50

525

BaseStationPanel

TheRxRateandTxRatearetheEthernettrafficreceiveandtransmitratesthroughtheHBS
underload.
ThebuttonbarprovidesthenecessaryfunctionalitytoconfigureandmanagetheHBS.
Table510:HBSDetailPanelbuttonbarfunctions
Menu
Icon

Purpose

CrossReference

HBSConfiguration

ConfiguringaHBS

RecentEventsLog

RecentEvents

PerformanceMonitor

PerformanceMonitoring

ActiveAlarms

ActiveAlarms

SpectrumView

SpectrumView
ThroughputChecking
a

ChangingtheSectorBand
HSUConnectionTable

DeactivatingtheHBS
a. Installeronly
TheforegoingdescriptionrelatestoanactivatedHBS.TheDetailPaneltitlebarforaninactive
HBSlookslikethis:

ClickingtheActivatebuttoninitiatesanactivationWizard.TheActivatebuttoninthetitlebar
ishidden,leavingitlookinglikethis:

TheActivationprocessiscoveredindetailinChapter6.
Atanytime,thecurrentstatusoftheHBSisshownintheSectorStatusPanel,Figure 520.

RADWIN5000HPMPUserManual

Release3.5.50

526

HBSEventsLog

HBSEventsLog
TheEventsLogrecordssystemfailures,lossofsynchronization,lossofsignal,compatibility
problemsandotherfaultconditionsandevents.

Note

Theforegoingeventtypesincludeeventsfromalllinksforwhichthis
managingcomputerhasbeendefinedasthetrapsaddress.Onlyevents
fromRADWINequipmentwillbeshown.

Alarms(traps)aredisplayedintheEventsLoginthelowerpanelofthemainwindow.The
EventsLogmaybesavedasatextfile.
TheEventsLogincludesthefollowingfields:

Sequentialnumber(ID)
Dateandtimestamp
Message
Trapsource
IPaddressoftheODUthatinitiatedalarm.

ForcompleteinformationaboutinternaltrapsandalarmsseeChapter12.
TheeventsaredisplayedintheEventsLoginthelowerrighthandpaneloftheRADWIN
Managermainwindow:

Figure522:EventsLogpanel
Theeventslogprovidesacolorcodedeventlist.Blueitems(liketheoneinFigure 522)are
informational.Youcansetthecolorcodingforcritical,cautionaryandinformational
messagesfromthePreferencesbutton.
TheEventsLogishorizontallyscrollableifitistoowideforyourcomputerdisplay.
Usethetopleftdropdownlisttofilterthemessages:

Figure523:EventsLogfilterselection

RADWIN5000HPMPUserManual

Release3.5.50

527

HBSMainWindowHSUsPanel

HBSMainWindowHSUsPanel
TableViewFurtherdetails
IfyouhavealargenumberofHSUsinthesector,itmaybehelpfultofilterthedisplay.You
havethefollowingchoices:

Thefollowingcasehascoloredfieldsindicatingaproblemrequiringyourattention:

Figure524:HSUcardindicatingaproblem
IfyoumouseoverthecoloredRSSarea,youwillreceiveatooltiptellingyouthatRSSfor
Radio1islowerthanforRadio2,orsomethingsimilar.Wewillprovidefurtherdetailabout
thesecolorcodesbelow.
RightclickaHSUtogetitscontextmenu:

Figure525:HSUdisplaycontextmenu(rightclick)

RADWIN5000HPMPUserManual

Release3.5.50

528

HBSMainWindowHSUsPanel

MapView
HereagainistheMapviewoftheHBSMainWindow:

Figure526:HBSMainWindowMapview
HBS/HSUStatusLights

HBS/HSUStatuslightappearonthetowergraphic,
Figure 524).

RADWIN5000HPMPUserManual

Release3.5.50

andtheHSUdetail(forexample,

529

HBSMainWindowHSUsPanel

ThemeaningoftheStatuslightsisasfollows:
Table511:HBS/HSUStatuslightcolorcodes
Description
Color
HBS

HSU

Green

Active

Registered,insync

Red

Inactive

Registered,nosync

Purple N/A

Authenticationerror

Brown

N/A

SoftwareUpgrade
required

N/A

Belongstoanother
sector

Figure527:HBS/HSU
Blue
Statuslights

Static:Unregistered
Gray

N/A

Mobile:Not
synchronized

NavigationToolbar
Thelefthanddisplayboxshowsthelatitudeandlongitudeofthepointonthemapunderthe
tipofthemousecursor.
Therighthandbaristhedistancescaleasdefinedbythenumericlabel25kminthe
example.

Figure528:NavigationToolbar
Table512:Navigationtoolbarbuttonfunctions
MenuIcon

Purpose

Show/HidetheHBS/HSUStatuslights(Figure 527)
Show/HidetheHBS/HSUStatusboxes
Centeronthesector

RADWIN5000HPMPUserManual

Release3.5.50

530

HBSMainWindowHSUsPanel

Table512:Navigationtoolbarbuttonfunctions(Continued)
MenuIcon

Purpose

Showsdifferentmapviews.
AerialViewandShowLabelsare
setbydefault.

Navigationbuttons:Movesthesectoraboutonthe
displayedmap.

Showsdifferentlevelsofmap
detail

Thezoomitem
isaconveniencefunction.Thefoursidebuttonsshowthedetaillevel
associatedwiththezoomsliderposition.Alternatively,youmayclickoneofthesidebuttons
togetdirectlytotheindicatedzoomlevel.ThedefaultlevelisRegioncorresponding
roughlytoanareasufficienttodisplaythewholesector.
OtherMouseNavigationFunctions
Doubleclickingthemouseorrotatingthescrollwheelforwardcausestheviewtozoom
in(becomelarger,moredetailed)
Rotatingthescrollwheelbackcausestheviewtozoomout(becomesmaller,less
detailed)
Movingthemouseoverthemapwiththerightbuttondepresseddragsthesector(cen
teredontheHBS)inthedirectionofmovement

Rightclickinganywhereonthemapopensupthis

closetothemouselocation.Clickingthisbuttoncopiesthemousecursorlocationasa
comaseparatedtextmodelatitudelongitudepairtotheclipboard.Hereisacopy/
pastedexample:37.58896,145.69000.

TheHSUStatusbox
Thefollowingcaseshavecoloredfieldsindicatingaproblemrequiringyourattention:
RADWIN5000HPMPUserManual

Release3.5.50

531

HBSMainWindowHSUsPanel

Figure529:HSUstatuscardsindicatingproblems
IfyoumouseoverthecoloredRSSarea,youwillreceiveatooltiptellingyouthatRSSfor
Radio1ishigherthanforRadio2,orsomethingsimilar.Thecolorcodeshavethefollowing
meanings:

Normalwhite/greentogetherwithaconsistentRSSimbalancemaybecausedbydiffer
entTXPowersettingsateachsite.Thereisnowarningindicatorbutitmaybeeasily
correctedusingConfigure|Tx&AntennaorbyrerunningtheConfigurationwizard.
AyellowwarningcolorwillbedisplayedforanRSSdifferenceofmorethan8dBm
betweenthetwopolarizationsonthesamesite(theRSSdisplayisthecombinationof
bothpolarizationsonthissite)
AredwarningcolorindicatesanRSSdifferenceofmorethan16dBmbetweenthetwo
polarizationsonthesamesite

Thelattertwocasesareusuallytheresultofaphysicalproblemattheindicatedsite.Probable
causesare:

Interference
Antennapolarityproblem
ODUmalfunction

Thisisanormalsituation:

Figure530:HSUstatuscards:Left:fixedHSURight:nomadicHSU

RADWIN5000HPMPUserManual

Release3.5.50

532

HBSMainWindowHSUsPanel

Thearrowonthetoprighthandcornercanbeusedtominimizeorrestorefulldetail.Hereis
theHSUstatusboxminimized:
withasmalldisplay.

Thisdeviceisusefulforalargesector

RightclickanHSUimagetogetitscontextmenu:

Figure531:HSUdisplaycontextmenu(rightclick)

ListView
ListviewfunctionalityisobtainednyselectingaHSUandusingthetopbuttonbarto
configureit.

Figure532:HSUsonHBSdisplayextract.ScrollrightformoreHSUfields
IfyouhavealargenumberofHSUsinthesector,itmaybehelpfultofilterthedisplay.You
havethefollowingchoices:

RADWIN5000HPMPUserManual

Release3.5.50

533

ExploringtheRADWINManagerMainWindowHSU

ThebuttonbarinFigure 532followsthesamepatternasthecontextmenusinFigure 525..


Table513:HBSmainwindowcontextmenuandbuttonbarfunctions
MenuItem

Menu
Purpose
Icon

CrossReference

Register

RegisteraHSUtoasector

RegisteringafixedHSUfor
service

Configure

SiteconfigurationfortheHSU

ConfiguringanHSUfrom
theHBSMainWindow

RecentEvents

RecenteventslogperHSU

RecentEvents

Performance
Monitoring

PerformanceMonitoringperHSU

PerformanceMonitoring

ActiveAlarms

DisplayActiveAlarms

ActiveAlarms

Estimate
Throughput

EstimatethroughputperHSU

ThroughputChecking

UpdateService

Serviceevaluationandtimeslot
allocationperHSU;alsoSpatial
Multiplexing/Diversityselection

UpdatingHSUServices

Suspend...

SuspendService

SuspendinganHSU

Replace

ReplaceaHSU

ReplacinganHSU

LocateonMap

FlytothisHSUontheMapDisplay

Reset

ResettheHSU

Deregister

DeregistertheHSU

CopyHSUList

CopiesHSUList(showingserialno).
toclipboard

DeregisteringanHSU

ExploringtheRADWINManagerMainWindow
HSU
YoumaylogontoaHSUovertheairfromaHBSorbydirectlyconnectingaManaging
ComputertotheHSUwhetherthroughaswitchordirectlytoitsPoE.Youcanlogonoverthe
airtoanyregisteredHSU.TheHSUmainwindowisdifferentfromtheHBSmainwindow,
howeveritusesthesameGUIandthesamelabelsforcommonentryfields.
RADWIN5000HPMPUserManual

Release3.5.50

534

LoggingontoaHSU

LoggingontoaHSU
YoucanlogontoaHSUofanestablishedsector.Thelogonprocedureisthesameasfora
HBS.SupposewelogontoHSUwithIPaddress10.104.50.1:Weinitiallyreceivethefollowing
caution:

Figure533:LoggingontoaHSU
UponclickingOKtodismissthecaution,wegetavariationofthepreviousmainwindow:

Figure534:OpeningRADWINManagerwindowHSU

RADWIN5000HPMPUserManual

Release3.5.50

535

LoggingontoaHSU

ThedirectlogonwindowdiffersonlyinthebottomstatusbarwheretheConnectionMode
willshowNetworkinsteadofOvertheair.Thereareseveralfunctionaldifferencesbetween
thelogonmodes,whichwewillexplaininthefollowingchapters.

RADWIN5000HPMPUserManual

Release3.5.50

536

HSUMainButtonMenu

HSUMainButtonMenu
TheHSUmainbuttonmenuissimilartotheHBSmainbuttonmenu.Theonlynewitemisin
theConfigurebutton.

Figure535:HSUmainbuttonmenu
Table514:HSUmainbuttonbarfunctions
MenuItem

Purpose

TheConfigurebuttonopensHSUsiteconfiguration.Theadditional
functionsinthedetailmenuworkinthesamewayasthecorresponding
functionsfortheHBS.

Configure

SeeSoftwareBackupandUpgradeforthefifthandsixthitems.
MonitorFilelocation,intervalandthroughputunits
Preferences

EventsColorcodingforeventslogandeventslogfilelocation
AdvancedEnable/disablecheckforupdates,Monitoringintervaland
timeout

GetDiagnostics

Runandstorediagnosticsforallorsomemembersofasector

LogOff

Returntologonwindow
LinkBudgetCalculator

Helprightarrow

Checkforupdates
About

HelpButton

ViewthisUserManual

RADWIN5000HPMPUserManual

Release3.5.50

537

HSULinkStatus

HSULinkStatus

HSUEventsLog
TheHSUeventsdisplayisfunctionallyidenticaltothatoftheHBS.

HSULinkPerformance

Forconvenience

TheHSULinkPerformancepanelshowsthesamefieldsasinFigure 530.Forconveniencewe
alsodisplaythecorrespondingparametersfortheHBS.Thethroughputbargraphsandlabels
havethesamemeaningasthecorrespondingitemsontheHSUcards.

RADWIN5000HPMPUserManual

Release3.5.50

538

SettingRADWINManagerPreferences

SettingRADWINManagerPreferences
ThePreferencestabsappearingonboththeHBSandHSUrelateentirelytothewaythe
Managerdisplayscertainitemsfortheconnectedunit.Theyarecompletelylocaltothe
managingcomputer.TheyarealsofunctionallyverysimilarforboththeHBSandHSUs.
Eachtechnicianservicingasectorwillneedtosetuphismanaging
computer(typicallyalaptop)withhisownpreferences.

Note

Monitor

Figure536:MonitorPreferencesHBS

RADWIN5000HPMPUserManual

Release3.5.50

539

Monitor

Figure537:MonitorPreferencesHSU
TheMonitorfilecontainsavastamountofinformationandcanbecomeinordinatelylarge
veryquickly.Youshouldthereforechoosealongersamplingintervalifyouintendtostorethis
informationforalengthyduration.
FortheHBS,itwillshowdetailsfortheHBSitselfandallregisteredHSUs.TheKMZbuttonis
onlyrelevanttoMobilitysectorsandotherwisedoesnothing.
ForaMobilitysectoritopensastandardfilesearchdialog.Ifyounavigatetothelastsaved
Monitorfile,itextractsGPSinformationforVMUsandcreatesaKMZfilereadablebyGoogle
Earth.
ThelatterwillshowyouthepointstraversedbyVMUsduringtherecordingperiod.
ForaHSU,itwillrecordtheinformationjustforthatHSU.Youshouldusedistinctivefile
namesforHBSandHSUMonitorfiles.
ThecontentoftheMonitorfilewillbediscussedinmoredetailinChapter12.
TheUtilizationfileshowsthedataattherequestedintervalappearingatthebottomof
Figure 104.Italsocanbecomeverylargeveryquickly.
TheShowIPitemisusefulifyouareusingbothIPv4andIPv6addresses.Thechoiceof
compressedaddresseswilldropleadingzerosandusethe::notationwhereappropriate.For
example,theexpandedaddress,FE80:0000:0000:0000:5AFE:00AA:20A2compressesto
Fe80::5AFE:AA:20A2.
SwitchingtheShowIPandAddressFormatitemsresultinimmediate
displayupdatingwithoutthenedtopressOKorApply.

Note

RADWIN5000HPMPUserManual

Release3.5.50

540

Events

Events

HereyoumaychooseyourowncolorcodingfortheRecentEventdisplay(seeMonitoringand
Diagnostics).
Youmayalsochoosealocationandfilenamefortheeventslogforstorage.Thesesettingsare
again,perHBSorHSU.Toavoidoverwriting,youshouldusefilenamesreflectingtheir
sourceODU.
TheSNMPv3UserandPasswordarerelevantifyouareusingSNMPv3.Inthis,casetrap
messagesarekeyedtotheusernameandpasswordandnotvisibletoanyoneelse.The
preferencesenteredhere,relatetotrapmessagessenttothespecifieduserifspecifiedorto
alltrapmessages,otherwise.Forassociatingauserwithatrapaddress,seeChapter8,
Management.

RADWIN5000HPMPUserManual

Release3.5.50

541

Advanced

Advanced

Figure538:AdvancedPreferencesHBS

Figure539:AdvancedPreferencesHSU

ChangePassword
Youmaychangeyourlogonpasswordherefromthedefault,admin.

RADWIN5000HPMPUserManual

Release3.5.50

542

WhatComesNext?

RestoreAlerts
ManyalertmessagesintheRADWINManagerhaveanoptionoftheformDonotshowthis
messageagain.Thesealertmessagescanberevertedtotheirdefaultstate(shown)by
clickingtheRestoreAlertsbutton.Youwillbeaskedtoconfirm:

CheckforUpdates
IfyouarenotconnectedtotheInternet,disabletheCheckforupdatescheckbox.

EnableRSSBalanceIndicationforMobility
CheckingthisitemplacesacoloredrectanglearoundunbalancedRSSfieldsincardview.

EnableRSSExtendedView
CheckingthisboxenabledanextendedcardinTableview.SeeFigure 68andFigure 92.

MonitoringandTimeoutIntervals
ThemonitoringintervaldeterminesthelowestintervalbetweenrequesttotheODUfor
statusupdates.Thetimeout(default1sec,maximum5sec)mayhavetobeincreasedifyou
areonaslownetwork.

SettingtheMapViewBackgroundMode
Youhaveachoiceoftwomapproviders,adefaultoraselfchosenbackground.Ifyoulogon
withoutanInternetconnection,youwillgetadefaultgraybackgroundor,ifyouhavecaching
enabled,yourlastusedmap.

WhatComesNext?
ThepurposeofthischapterwastoofferanoverviewofarunningRADWIN5000asector.The
nextthreechapterswillcoverrespectively,detailedsectorsetupconsiderations,sector
managementandmonitoringanddiagnostics.Theforegoingbackgroundshouldprovide
sufficientsignpoststoensurethatyoudonotbecomelostintheplethoraofdetails
requiredtocommissionandmanageafullyoperationalsector.

RADWIN5000HPMPUserManual

Release3.5.50

543

Chapter6:

InstallingtheSector
ScopeofthisChapter
Chapter5offeredanoverviewofarunningSectorasmotivationforthetechnicalinstallation
detailssetoutbelow.
AssumingthattheSectorequipmentisinplaceasdescribedinearlierchapters,sector
installationhastwophases:

ConfiguringandactivatingtheHBS
BringinguptheHSUsconfigurationandregistration

ThesameRADWINManagerprogramisusedforboththeHBSandtheHSUs.Muchofthe
processiscommontobothtypesofODU.WewillcovertheHBSindetail;fortheHSUswewill
concentrateonthoseitemswhicharedifferent.Inanyevent,wheresetupproceduresare
commonwewillpointthemout.
ThischaptercoversfixedandnomadicHSUconfigurations.MobileHSUsarecoveredin
Chapter11.

Concepts
AHBSoutofthebox,mustbeconfiguredwith

BasicRFparameterssuchasfrequencyband,channelbandwidthsandSectorID
NetworkingparameterssuchasIPaddress,subnetmaskanddefaultgateway

Atthispoint,theHBSisinaninactivestate,poweredup,configurablebutnottransmitting
anything.
Uponactivation,theHBSwillcommencetransmittingandreceivingpacketsrelatedtosector
managementonlythatisnoservice.ActivationandDeactivationareeffectedquitesimply
byclickingatogglebutton.
AssumingthattheSectorHSUsaremountedalignedandpoweredup,theHSUswilldiscover
theHBSestablishinglinksformanagementonly.AtthispointtheHSUsmaybemanagedover
theair.
RADWIN5000HPMPUserManual

Release3.5.50

61

WorkingwithNomadicHSUs

AssoonastheHSUsareconfiguredtoyoursatisfaction,youmustregisterthemontheHBS.
RegistrationofanHSUenablesservicetrafficbetweentheHSUandtheHBS.TheHBSkeeps
trackofregisteredHSUsbymaintainingatableoftheirMACaddresses.RegisteredfixedHSUs
setaninternalflagsothattheycannotregistersimultaneouslytomorethanoneHBS.
Duringtheregistrationprocess,youassigntimeslotstoeachHSU.Atotalof63timeslotsare
availabletoeachHBSineachoftheuplinkanddownlinkdirections,tobedistributedamong
theHSUsinthesector.Therelativenumberoftimeslotsdeterminestherelativeamountof
serviceeachHSUwillreceive.EachHSUreceivesatleasttwotimeslots.TodisableanHSU
youmustderegisterit.(Asuspendmechanismisalsoavailable,tosuspendserviceonanHSU
foralimitedperiod.)
ForeachregisteredHSU,youcansetseparately,theuplinkanddownlinkMaximum
InformationRate(MIR)inMbpsorleaveitasUnlimited.
YoumayalsomanageanHSUConnectiontabletoenableanddisableconnectivitybetween
HSUsinasector.
HSUsmaybefixedornomadic.Thelattermaybemovearoundwithinandacrosssectors.
MobileHSUs(HMUs)mayalsomovearoundwithinandacrosssectors.Theyarecoveredin
Chapter11.

WorkingwithNomadicHSUs
EachnomadicHSUisallocatedtooneoffourHBSlevelslabelledA,B,CandD.Some
operatingparametersforeachlevel(suchasVLAN,MIR,QoS,timeslots,fixedrate,Spatial
Multiplexing/Diversityantennamode)canbedifferentforeachlevelallowingforbroad
prioritizationofservicebetweendifferenttypesofnomadicunits.Thisrequiresthateach
nomadicHSUbeassignedaleveltojoinasector.
AnomadicHSUmayonlysendandreceiveservicetrafficwhilestationary.AnomadicHSU
detectsthatitistimetoseektheanotherHBSuponsyncloss.Uponenteringandstoppingin
anewsector,itmaytakeseveralsecondstoestablishsyncwiththesectorHBS.
ChanginganyofVLAN,MIR,QoS,fixedrate,SpatialMultiplexing/Diversityantennamodefor
oneconfiguredHSUatagivenlevel,changesallotherHSUsatthatlevel.Ifyouaddanew
HSUtoasector(bydirectconnection)atagivenlevel,atsynctime,itwillacquiretheexisting
parametersforthatlevel.

Workflow
Inthischapter,weassumethatyouarefamiliarwiththegraphicaluserinterfacedescribedin
Chapter5,includingGeographiclocation.Wewillconcentratehereonsectorradiosetup
workflow.Tothisend,theinstallationwillbecarriedoutagainstablankwhitebackground.At
theendoftheprocesswewillcompletethesectorbyopeningthemaptoreflectour
Geographicpositioningdata.
Priortocommencing,youshouldhaveawrittensectorplanalongthelinesofTable 62.

RADWIN5000HPMPUserManual

Release3.5.50

62

DefaultRADWIN5000HPMPSettings

DefaultRADWIN5000HPMPSettings
ThedefaultsettingsoftheRADWIN5000HPMPconfigurationparametersarelistedin
Table 61below.
Table61:Defaultsettings
Unit

HBS

Parameter

DefaultValue

IPAddress

10.0.0.120

NetMask

255.0.0.0

DefaultGateway

0.0.0.0

Location

Location

Contact

Person

Name

Contact

Protocol

SNMPv1

Factorydefaultband

Product
dependent

ChannelBandwidth

20MHz

RADWINManagerlogonpasswords
Observer

admin

Operator

admin

Installer

wireless

LinkPassword

wirelessp2mp

Geographiclocation
Latitude

51.47885

Longitude

0.01060

Antennaheight(m)

130

RADWIN5000HPMPUserManual

Release3.5.50

63

DefaultRADWIN5000HPMPSettings

Table61:Defaultsettings(Continued)
Unit

HSU

Parameter

DefaultValue

IPAddress

10.0.0.120

NetMask

255.0.0.0

DefaultGateway

0.0.0.0

Location

Location

Contact

Person

Name

Name

Protocol

SNMPv1

RADWINManagerlogonpasswords
Observer

admin

Operator

admin

Installer

wireless

LinkPassword

wirelessp2mp

RADWIN5000HPMPUserManual

Release3.5.50

64

DefaultRADWIN5000HPMPSettings
For convenience, we repeat the tables of parameters used in our demonstration sector.
Parameters not listed are left at their default values:

Table62:PreconfiguredsetupHBS
Location

Attribute

IPv4

IPv6

Value

Address

10.104.50.200

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::200

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSinthesame
subnet

SectorID

EBGX20560334

InheritedbyallcommunicatingfixedHSUs.

NetworkID

EBX

Inheritedbyallcommunicatingnomadic

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1andv3

Contact

Bach

Optional

Name

Bach@HBS.01

LocationofContactoptional

Band

5.7305.845GHzFCC/IC

InheritedbyallcommunicatingHSUs

ChannelBandwidth

20MHz

InheritedbyallcommunicatingHSUs

UnitSerialNumber

PET540E000A00000

HBS.01

Geographiclocation
Latitude

37.8148

Longitude

144.9630

Azimuth(deg)

Beamwidth(deg)

90

Antennaheight(m)

130

UsedforinitialdefaultplacementofHSUs

RADWIN5000HPMPUserManual

Release3.5.50

FromRFplan,notused

65

DefaultRADWIN5000HPMPSettings

Table63:PreconfiguredsetupHSUs
Location

Attribute

IPv4

IPv6

Value

Address

10.104.50.1

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::1

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSin
thesamesubnet

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Haydn

Optional

Name

Haydn@HFU.01.01

LocationofContactoptional

HFU.01.01
Downlink

Uplink

TimeSlots

Mayvarywithcontext

UnitSerialNumber

P07030E000A0003E

Geographiclocation
Latitude

37.89651

Longitude

145.15716

Antennaheight(m)

10

IPv4

IPv6

Address

10.104.50.2

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::2

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

FromRFplan,notused

AllcommunicatingHSUsandHBSin
thesamesubnet

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Mozart

Optional

Name

Mozart@HFU.01.02

LocationofContactoptional

HFU.01.02
Downlink

Uplink

TimeSlots
UnitSerialNumber

Mayvarywithcontext
P07030E000A000422

Geographiclocation
Latitude

37.62400

Longitude

145.21484

Antennaheight(m)

60

RADWIN5000HPMPUserManual

Release3.5.50

FromRFplan,notused

66

DefaultRADWIN5000HPMPSettings

Table63:PreconfiguredsetupHSUs(Continued)
Location

Attribute

IPv4

IPv6

HFU.01.04
(Usedonlyto
illustrateAES
265)

Value

Address

10.104.50.4

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::4

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSin
thesamesubnet

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Handel

Optional

Name

Handel@HFU.01.04

LocationofContactoptional

Downlink

Uplink

TimeSlots

Mayvarywithcontext

UnitSerialNumber

P07030E000A0003B

SupportsAES256

Geographiclocation
Latitude

37.4018

Longitude

145.0086

Antennaheight(m)

60

FromRFplan,notused

Table64:PreconfiguredsetupLevelallocationformaximumnomadicHSUs
Level

Numberof
nomadicHSUs

TimeSots
Downlink

Uplink

RADWIN5000HPMPUserManual

Release3.5.50

Remark
IncludesHNU.0.01below

67

ConfiguringtheSectoroutoftheBoxIPAddresses

Table65:Preconfigured setup - one nomadic HSU


Location

Attribute

IPv4

IPv6

Value

Address

10.104.50.3

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::3

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSin
thesamesubnet

HNU.01.01
Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Brahms

Optional

Name

Brahms@HNU.01.01

LocationofContactoptional

Downlink

Uplink

TimeSlots
UnitSerialNumber

Mayvarywithcontext
P07030E000A0003B

WehavealsoaddplaceholdersforfournomadicHSUs.Thatis,uptofourvehiclesequipped
toworkinthisway,maysimultaneouslyenterthesector.

Tip

Chooseyourunitlocationscarefully.Forexample,forthreecollocatedHBSs
eachwith32HSUscovering360,mattersgetoutofhandveryquicklyif
unitsarepoorlynamed.TheycanalwaysbeidentifiedbytheirIPaddresses,
butthatisapoorsubstituteforeffectivenaming.AURLlikenamingpattern
basedonHBS_n.HSU_yisclearandfamiliartoallInternetusers.Keeping
thenamesIPaddressindependentenablesyoutocopytheentiresector
setuptoadifferentgeographiclocationwithoutIPaddressduplication.

ConfiguringtheSectoroutoftheBoxIP
Addresses
ThedefaultlogonIPaddressforallODUsinthesectoristhesame:10.0.0.120,subnetmask
255.0.0.0anddefaultgateway0.0.0.0.Togettheprocessstarted,setuptheIPaddressonthe
networkcardonthemanagingcomputertosomethinglike10.0.0.100,subnetmask
255.255.255.0andDefaultGateway0.0.0.0.
EnsurethatyouhaveadirectLANconnectiontotheHBS,runtheRADWINManagerandlog
ontoit.

RADWIN5000HPMPUserManual

Release3.5.50

68

ConfiguringtheSectoroutoftheBoxIPAddresses

Figure61:LoggingonwithfactorydefaultIPaddress
Alternatively,youcanlogonusingLocalConnectionwithoutneedtochangeyourNetwork
InterfaceCardaddress:

Figure62:LoggingonwithLocalConnection

TheLocalConnectionmethodusesbroadcastpacketstodiscover
theattachedODU
IfyoulogonusingLocalConnection,butyourphysicalconnectionis
notlocal(i.e.anythingotherthanadirectconnectionbetweenthe
managingcomputerandthePoEdevice),thenanyconfigurationyou
carryoutmayaffectotherlinksinthenetwork.Donotdothis!
Donotcarryoutthisprocedureusingamultihomedmanagingcom
puteralsoconnectedtoanetwork.Itwillfloodthenetworkwith
broadcastpackets.Further,itwillthrowanyotherlinksonthenetwork
intoInstallationorInactivemode.

Warning

Inanyevent,asaprecaution,defaultlogonoverLocalConnectionis
readonlymode.ChecktheRead/Writeenableboxtocarryoutinstal
lationprocedures.
Networklogon(IPaddresstotheODU)isrecommended.

RADWIN5000HPMPUserManual

Release3.5.50

69

LogOnUsingaIPv6Address

LogOnUsingaIPv6Address
InManagement,weshowhowtoconfigurethelinktouseIPv6address.Loggingonwithan
IPv6addressworksasexpected,howeverthereareseveralcaveatstoitsuse:
1. ThereisnoLocalConnectionunderIPv6,sinceitdoesnotsupportIPv4stylebroadcast
ing.
2. IfyouareconfrontedwithanODUconfiguredforIPv6andyoudonothaveitsIPaddress,
thereisnosimplewaytologontotheunit.ThisisalimitationofIPv6,notthehardware.
Toresolvetheproblem,youwillneedtocontactCustomerService.
3. Toavoidthissituation,useweatherproofadhesivestickerstolabeleachODUwithitsIPv6
address.

TheInitialRADWINManagerMainWindow
HereistheinitialmaindisplayusingLocalConnection:

Figure63:MainwindowforunconfiguredHBSODU

RADWIN5000HPMPUserManual

Release3.5.50

610

TheInitialRADWINManagerMainWindow

Noticetheredicononthetopleftcornerofthewindow.Itwillchangetogreenassoonas
theHBSisconfiguredandactivated.Hereistheworkflow:
4. ActivatetheHBSwhichincludessettingitsIPaddress.ItwillthenseethedeployedHSUs
regardlessoftheirIPaddress.
5. ConfiguretheHSUs
6. RegistertheHSUstotheHBSfortraffic
7. CompleteHSUconfigurationincludingHSUConnectionTableandanyotherrequiredfine
tuning.

ToactivateaHBS:
1.ClicktheActivatebutton.TheActivationWizardopens.

2.ClickNext:

RADWIN5000HPMPUserManual

Release3.5.50

611

TheInitialRADWINManagerMainWindow

EntertheSectorID,NameandLocation.Allfieldsaremandatory.Hereareentriesin
accordancewithTable 62.
AbouttheSectorID:
AnyunregisteredHSUwillestablishalinkwiththefirstHBSitdetectsandinheritthe
SectorIDfromtheHBS.AssoonastheHSUisregisteredforservicewiththeHBS,the
HSUsinheritedSectorIDcannolongerbechangedwhilelinked:Itislockedinto
theHBS.ThismechanismpreventsanHSUclosetoasectorboundaryfromdrifting
betweenHBSsforadjacentsectors.
NoticethattheSectorIDissplitintotwopartsasshowninthepreviousfigure.Fora
networkconsistingofsectorswithfixedHSUsonly,thesplitisimmaterial.Ifthesec
torispartofanetworkhavingnonfixedHSUs,theneachSectorIDforeachpartici
patingsectorshouldhavethesamefourcharacterNetworkID.Theremainingpartis
ignoredwhenanHBSestablishesalinkwithanonfixedHSU.Thisfeatureenables
nonfixedHSUstoestablishalinkwithanyHBSinthenetwork.

RADWIN5000HPMPUserManual

Release3.5.50

612

TheInitialRADWINManagerMainWindow

TheSectorIDissplitintoafourcharacterNetworkID(EBGX)andtheremainingpart
(20561334).

ForfixedHSUsyoumayignorethesplit.FornonfixedHSUs,theuseofthesplitSec
torIDisexplainedonpage 94.
ChooseyourSectorIDitcarefullyparticularlyifyouareusingcollocatedHBSsfor
extracoverage.TheSectorNameandLocationareconvenienceitemsbutshouldbe
chosentoensurethatthesectorisdocumentedandeasilyidentifiableinyourRF
planning.
3.OpentheCoordinatesdialogtosetthelocationoftheHBSinaccordancewith
Table 62:

4.TheLinkPasswordmayalsobechangedbyclickingChange:

RADWIN5000HPMPUserManual

Release3.5.50

613

TheInitialRADWINManagerMainWindow

FulldetailsforchangingtheLinkPasswordmaybefoundonpage 819.
Itisbestleftasisifthereisnopressingneedtochangeit.
Ifyouskippedanentry,itwillbeframedinredlikethis:

Note
5.FromthepreviousActivationWizardwindow,clickNext.

HereyoumayentertheIPdetailsifdidntdoitearlier.ClickNext.
6.Thenextwindowisusedtosetthefrequencyandchannels.

RADWIN5000HPMPUserManual

Release3.5.50

614

TheInitialRADWINManagerMainWindow

Thedefaultfrequencyisthelowestavailable(5.735GHz)intheoperatingband,
here,5.7305.845GHzFCC/IC.
7.ClickOthertoseeotheravailablebandsforthisHBS.

8.Forourpurposes,wechoose5.820GHz:

RADWIN5000HPMPUserManual

Release3.5.50

615

TheInitialRADWINManagerMainWindow

righthandselectorwheel

Observethattherighthandspinwheel
isnolongerdisplayed.Hadyou
leftOtherenabled,youcouldhavechosenafrequencybyworkingthroughthose
availablein5MHzincrements.
9.ChoosetherequiredChannelBandwidth:

Ifyourhardwaresupports200Mbpsnetaggregatecapacity,youshould
chose40MHzChannelBandwidthtoenableit.

Note
10.TouseACS,checktheAutomaticChannelSelectionbox:

RADWIN5000HPMPUserManual

Release3.5.50

616

TheInitialRADWINManagerMainWindow

YoucanperformacustomizedchannelselectionorclickSelectAlltocheckallthe
channelboxesasshown:

AutomaticchannelselectionattheHBSmakeslittlesensebeyondconfiguration
time.Youmayleaveallorseveralofthechannelsselectedfornow.Inpractice,after

RADWIN5000HPMPUserManual

Release3.5.50

617

TheInitialRADWINManagerMainWindow

havingfullyconfiguredthesectoryouwoulddisableallbuttheactualoperating
channel.
ForoperationusingLicensed3.XbandsunderFCCpart90subpartZandIC
RSS197supporting3.6503.700GHz:TheHBSdoesnotcommenceany
typeoftransmissionuntiltheActivationprocessiscompleted,in
compliancewiththoseregulations.

Note

11.ClickNext.TheAntennatypeandTxPowerwindowispresented:

ThechoiceofTxPower,antennagainandcableloss(betweentheradioandthe
antenna)determinestheEIRPandisaffectedbysuchconsiderationsasradiolimita
tionsandregulatoryrestrictions.
Beforecompletingantennainstallation,youmightliketoconsiderthebackground
informationaboutsettingantennaparameters,inAppendixE:

Warning

WhensettingRequiredTxPower,itisyourresponsibilitytochoseavaluein
compliancewithyourlocalregulations.

ChooseyourAntennaType,RequiredTxPower,AntennaGainandCableLoss.We
willsetRequiredTxPowerto5dBmforourexample.ClickNext.
12.TheSummarywindowoftheWizardisdisplayed.

RADWIN5000HPMPUserManual

Release3.5.50

618

TheInitialRADWINManagerMainWindow

CheckthatallinformationshowediscorrectandclickActivate.Afterafewmoments
thesectorHSUswillbedisplayedintheManagerHSUpanel.
ThefieldinstalledHSUsappearinaTableview:

RADWIN5000HPMPUserManual

Release3.5.50

619

ConfiguringafixedHSUFromtheHBS

Figure64:ActivatedHBSrecognizinginstalledbutunconfiguredHSUs
IftherearetoomanyHSUsfortheTableview,switchtothescrollableListview.
13.IfyouareusingLocalConnection,logoutandlogbackintotheHBSonitsIP
address.
Atthispoint,youareabletoconfiguretheHSUsforservice.
Youmayhaveobservedthatoperatingfrequency5.735GHzshown,isnotwhatwechose
(5.820GHz).TheHBStriestooptimizethefrequencytominimizeinterferenceeffects.
WenextconfigureandregistertheHSUs.ForfixedHSUsyoucandothisineitherorder.For
nomadicHSUsyoumustdefinetheHSUasNomadicpriortoregistration.Wewillshowthe
methodbelow.OurpreferenceistocarryoutconfigurationfirstforallHSUs.

ConfiguringafixedHSUFromtheHBS
TheHSUactivitiesdescribedinthissection,maybecarriedoutanytimeregardlessof
whetherornottheHSUisregisteredforserviceornot.Theseactivitiesincludeamongother
things,settingtheLocation,Contact,NameandIPaddress.
TheproceduresinthissectionshouldbecarriedoutforeachfixedHSUinthesector.
RADWIN5000HPMPUserManual

Release3.5.50

620

ConfiguringafixedHSUFromtheHBS

ToconfigureafixedHSUfromtheHBS:
1.RightclickanHSUtogetitscontextmenu:

Figure65:HSUContextmenu
2.ClickConfigure.TheConfigurationdialogisdisplayed.Ifyouhavenotalready,entera
NameContactandLocation:

Locationisasitenametypicallyabuildingortowername.Contactisthecontact
personatthatLocationandNameistheContactlocation.Itmightbejustatele
phonenumber.Hereareourentries:
RADWIN5000HPMPUserManual

Release3.5.50

621

ConfiguringafixedHSUFromtheHBS

3.SettheCoordinates(latitudeandlongitude)fortheHSUasshownintheSectorPlan:

4.SettheHSUTxPower(possiblyasrequiredbyregulations).ClickTx&Antenna.The
followingdialogisdisplayed:

RADWIN5000HPMPUserManual

Release3.5.50

622

ConfiguringafixedHSUFromtheHBS

SettheAntennaConnectionType,AntennaType,RequiredTxPower,AntennaGain
andCableLossasrequired.Forourexample,weuseexternalantennas,wesetTx
Powerto5dBmandtheAntennaGainto15dBi.Ifyouclickapply,youreceiveacon
firmationrequestlikethis:

Thereareseveralvariationsofthismessagewindow,dependingonwhatyou
change:

RADWIN5000HPMPUserManual

Release3.5.50

623

ConfiguringafixedHSUFromtheHBS

5.Inanyevent,clickingYesresultsinafurthermessageappearing:

6.ClickOK.TheHSUdisplayarearefresheswiththenewlyconfiguredHSUinitsnew
locationinthesector.
7.ReopentheConfigurationdialogfortheHSUandthenopentheManagementtab.

RADWIN5000HPMPUserManual

Release3.5.50

624

ConfiguringafixedHSUFromtheHBS

ChangethedefaultHSUIPAddress,SubnetmaskandDefaultGatewayasshown:

8.Fornow,wewillleavetheremainingfields.ClickOKtoexittheConfiguration
window.Youwillbeofferedacautionarymessage:

ClickYes.ThenewlyenteredparametersfortheHSUwillbedisplayedfollowingthe
nextsyncloss/restoretotheHSU.Youcanachievethesamethingbyissuingarestto
theHSUfromitscontextmenu.
RADWIN5000HPMPUserManual

Release3.5.50

625

ConfiguringanomadicHSUFromtheHBS

9.Repeatsteps1to8foronemoreHSU.

ConfiguringanomadicHSUFromtheHBS

ToconfigureanomadicHSUfromtheHBS:
1.Carryoutsteps1to7asintheprevioussectionforafixedHSU.
2.OpentheNomadictab:

3.FromtheTypelist,chooseNomadic.TherighthandLevellistisenabled:

RADWIN5000HPMPUserManual

Release3.5.50

626

RegisteringafixedHSUforservice

4.ThefourlevelsenableyoutosplitnomadicHSUsintouptofourservicegroupswith
(forexample)differentQoSparameters.ChooselevelAandthenOK.Thenumberof
timeslotsallocatedtotheHSUwillbeupdatedduringtheregistrationprocess.You
areofferedthefollowingconfirmationmessage:

TheHSUnolongerappearsontheHBSTableview.Itwillreturnfollowingregistra
tion,towhichwenowturn.

RegisteringafixedHSUforservice
WecontinueourillustrationusingtheHSU,HFU.10.101.

ToregisteranfixedHSUforservice:
1.RightclickafixedHSUtogetitscontextmenu:

RADWIN5000HPMPUserManual

Release3.5.50

627

RegisteringafixedHSUforservice

2.ClickRegister...IfyoudidnotconfiguretheantennatypefortheHSU,youareasked
todosonow:

ChoosetherequiredtypeandclickOK.
TheRegistrationwindowopens:

RADWIN5000HPMPUserManual

Release3.5.50

628

RegisteringafixedHSUforservice

3.YoumayeditoraddthesiteName,LocationandCoordinates.
4.IfyouareusingDualAntennas,youmaycheckaMIMOMode:SpatialMultiplexing
(default)splitsthedataintotwostreamsontransmissionandrecombinesiton
receptionprovidingmaximumthroughput.Diversitytransmitsthesamedataon
frombothantennasandcheckforcorrectnessonreception.ThechoiceisHSU
specific.ForfurtherdetailsaboutMIMOantennamodes,seeAppendixE.
5.ClicktheEvaluatebutton.Serviceevaluationtakesafewsecondsduringwhichthe
windowisdarkenedandinactive.Uponcompletionyoumayassigntimeslotstothe
HSU:

RADWIN5000HPMPUserManual

Release3.5.50

629

RegisteringafixedHSUforservice

Figure66:HSURegistrationdialog
NoticethattheEvaluatingactivityiconcontinuestorotateaftercompletionofthe
evaluation.TheManagermaintainsdynamicmonitoringofthesectorforinjection
intothesectorofHSUselsewhereandaccordinglyreducestheavailabletimeslots.
6.Usethesliderstochoosethenumberoftimedownlinkanduplinkslotstobe
allocatedtotheHSU.

RADWIN5000HPMPUserManual

Release3.5.50

630

RegisteringafixedHSUforservice

Thetimeslotallocationsmaybechangedlater.
7.UsethesliderstosetUplinkandDownlinkMaximumInformationRate(MIR).You
maydeferthisandcarryitoutusingtheHSUConfigureoption.TheMIRactsasa
throttle.
8.ClickRegisterittocompletetheprocess.Hereistheresultforourexample:

Figure67:TworegisteredHSUcardsmediumview
IfyouenabledRSSExtendedViewinPreferences(seeEnableRSSExtendedView),
thenthedisplaylookslikethis:

Figure68:TworegisteredHSUcardsextendedview

RADWIN5000HPMPUserManual

Release3.5.50

631

RegisteringanomadicHSUforservice

ObservethattheregisteredHSUiconLEDisnowgreenandthatthetimeslotsbaron
theleftreflectstheproportionofuplinkanddownlinktimeslotsallocated.
9.Repeatsteps1to8forotherfixedHSUs.

RegisteringanomadicHSUforservice
AlthoughweonlyhaveonenomadicHSUinourdemonstrationsector,inpracticewewould
makeprovisionforalargernumbertoenablemovementbetweensectors.Bywayof
example,wewillpreregisterfourHSUslotstolevelsA,BandCandtimeslotstoeachlevelas
shown:

ToconfigurenomadicHSUsfromtheHBS:
1.OpentheHBSConfigurationwindowandthenitsNomadicTab:

Figure69:HBSNomadicConfiguration

RADWIN5000HPMPUserManual

Release3.5.50

632

TheFinalOutcome

2.IntheAddDeviceswindow,clicktheAddspinwheelbuttonsandthetimeslotsspin
wheelsasshown.

3.ClicktheRegisterbuttontoregistertheHSUs.Notethatyoumayusethebottom
dialogtosaveoruploadasavedHBSconfiguration.Wewilldemonstrateuploadinga
savedconfigurationattheendofthischapter.
4.ExittheConfigurationdialog.

TheFinalOutcome
Hereistheoutcomeforourexample:

Figure610:FullyfunctionalmixedfixedandnomadicsectorTableview

RADWIN5000HPMPUserManual

Release3.5.50

633

TheFinalOutcome

IfyouhavetoomanyHSUstofitthetableview,youcangetareducedtableviewbyusingthe
righthandHSUbutton:

Figure 610lookslikethis:

HereisaMapviewofthesector:

Figure611:FullyfunctionalmixedfixedandnomadicsectorMapview

RADWIN5000HPMPUserManual

Release3.5.50

634

ChoosingDiversityAntennaModeDuringRegistration

YoumaynowcarryoutanyotheradjustmentstotheHSUsfromtheHBSorbydirect
connection.NoticethatweadjustedtheTxPowerforallelementsinthesectortokeepthe
RSSatareasonablelevel.
Asapartialalternativemethod,youmayentertheHSUNameandLocationfieldsduring
Registration.
Ifyoudonotseethechangesasshown,ahardresetoftheHSUswillcause
themtoappear.

Note

ChoosingDiversityAntennaModeDuring
Registration
SupposethatinFigure 610forHFU.10.101wehadchosenDiversitymode,theoutcome
wouldlooklikethis:

TheassuredthroughputinbothdirectionsonthisHSUhasdroppedtoabouthalfofits
previousvalue.(TheRxandTxratesdropslightly.Thereasonthatthereisnosignificant
changetotheRxandTxratesisthattheSBMmechanismisallocatingadditionaltimeslotsin
bothdirections.SeeChapter10fordetailsabouttheoperationofSBM.)TheotherHSUsare
leftunchanged.
ThisunderlinestheflexibilityoftheRADWIN5000systemwhichenablesHSUstobe
independentlyconfigureddependingontheirparticularlocation.

DeactivatingtheHBS
FromtheHBSbuttonbar,clicktherighthandbuttonfollowedbyDeactivate.

RADWIN5000HPMPUserManual

Release3.5.50

635

DeactivatingtheHBS

Youareofferedacautionarymessage:

Ifyouproceed,theHBSdisplaywillchangetoreflectthedeactivatedstate:

NoticethattheHSUsremainregistered,andwillreturntofullserviceaftertheHBSisre
activated.

RADWIN5000HPMPUserManual

Release3.5.50

636

DeregisteringanHSU

DeregisteringanHSU
AHSUmaybederegisteredbyusingtheDeregisterentryinanHSUcontextmenuorusingthe
buttonfromanHSUbuttonbar.

WherehasmyHSUgone?
SupposethatyouinstalledtwocollocatedHBSswithcontiguoussectors.Itispossiblethatan
HSUlocatedclosetothecommonsectorboundarymaydiscoverthewrongHBS.AHSUcan
beforcedacrosstoanotherHBSbychangingitsSectorIDtothatoftherequiredHBS.The
methodfordoingthisiscoveredinChapter9.

SavingtheHBSSettingsforReuseasa
Template
RefertoFigure 69ofwhichthefollowingisanexcerpt:

Followinganyfurtherfinetuning,openuptheHBSNomadictab,andclickSave.Youare
offeredthestandardSaveFiledialog.SavetheHBSNomadicsettingsfile
(MobilitySettings.mob)toaconvenientlocation.Forourexamplewechangedthefilename
toNomadicSettings.mob.

CreatingNomadicEntriesforaSectorfroma
HBSTemplate
Thesavedsettingsfilemaybeusedasatemplateforfurthersectors.

TocreateasectorfromaHBSNomadicsettingsfile:
1.StartingwithanewHBSandHSUs,logontotheHBS.
2.ActivatetheHBSintheusualway.
3.OpentheNomadictabintheConfigurationwindow.IntheSave/UploadSettings
window,clickUpload.*

RADWIN5000HPMPUserManual

Release3.5.50

637

CreatingNomadicEntriesforaSectorfromaHBSTemplate

Figure612:PreparingtouploadtheNomadicfile
4.InourcasewehaveoneHBS,soitissufficienttoentertheNomadicfileasshown
andthenclickStart.Afterafewmoments,theStatusfieldindicatesDone.

Theresultisasexpected:

NoticethatouronerealnomadicHSUhascomeupconfiguredandregistered.Thefixed
HSUsmustberegisteredbyhand.

RADWIN5000HPMPUserManual

Release3.5.50

638

CreatingNomadicEntriesforaSectorfromaHBSTemplate

TocreateasectorfromaHBSIPlistandaNomadicsettingsfile:
1.InthewindowofFigure 612,enteraHBSlistfile.Theformatofthefileislinesof
<IPaddress><ReadWritecommunity>

Forexample,
10.104.50.200netman
AlloftheHBSsneedtoactivatedandaccessible(viaaswitch)tothemanagingcom
puter.Theyneednotbeonthesamesubnet.
Alternatively,enterthemonebyoneusingthePlusbutton.
AnyunactivatedHBSswillbeshownasunavailable:

2.MakeanyfurtherchangestothedisplayedlistusingthePlus/Minusbuttons.
3.ClickStarttocommencetheprocess.
4.ThelistwindowwillindicatethesuccessorotherwiseoftheuploadforeachHBS.

RADWIN5000HPMPUserManual

Release3.5.50

639

Chapter7:

OperatingUndertheFCC
UnrestrictedContentionBased
Protocol
ScopeofthisChapter
ThischapterexplainshowtosetupaRADWIN5000sectoroperatingundertheFCC
UnrestrictedContentionBasedProtocol(UCBP)inthe3.6503.7GHzbandThedetailed
technicaloperationoftheprotocolisbeyondthescopeofthismanual.Avarietyof
publicationsonthesubjectareavailablefromtherelevantFCCWebsite,http://
wireless.fcc.gov/services/index.htm?job=service_home&id=3650_3700.Seealso,http://
hraunfoss.fcc.gov/edocs_public/attachmatch/FCC0556A1.pdf.

BringingupaSector
TheHBSforFCCUCBPispreconfiguredforthisregulationonly.Activationisthesameasfor
otherRADWIN5000products.Followingactivation,theHBSwillfinditsHSUsintheusual
way.TheonlyadditionalrequirementsaretwoextraparameterstobesetintheConfiguration
AirInterfacetab:

RADWIN5000HPMPUserManual

Release3.5.50

71

HSUOperation

Figure71:AirInterfaceTabforFCCUCBP
TheMaximumThroughputModeisirrelevanthereandshouldbeleftasis.TheSharing
Percentage,(between1575%,default50%)isthemaximumcapacitytheHBSispreparedto
relinquishinfavourofothertransmittersonthisband.(Theremaybeseveral.)TheMinimal
Contentionslotlength(520ms,default10ms)istheamountoftimetheHBSispreparedto
waittocheckagainforchannelavailabilityandifstillnotavailable,totransmitregardless.
Basicallytheideaisthis:SupposethattheHBSissettoSharingPercentageofsay20%and
MinimumContentionSlotlengthof10msasshown.Itsays,Iampreparedtobepoliteand
relinquishupto20%ofmycapacitybutIwillbuttinandtransmitaburstfrom10msafter
interferencedetection.
Theremainingtabsworkasexpected.

HSUOperation
SincetheHSUstaketheircuefromtheHBSinrespectofairinterfaceparameters,nothing
specialisrequiredintheirconfigurationandtimeslotallocation.OldermodelHSUs

RADWIN5000HPMPUserManual

Release3.5.50

72

HSUOperation

configuredforthe3.6503.7GHzbandshouldworkcorrectlybutyoushouldcheckwith
RADWINCustomerServicebeforeusingthemforUCBP.

RADWIN5000HPMPUserManual

Release3.5.50

73

Part3:SectorManagement

Release3.5.50

Chapter8:

ManagingtheSector
ScopeofthisChapter
ThischapterdealswithmanagingthesectorfromtheHBS.ItcoversHBSConfigurationand
HSUConfigurationfromtheHBS.HSUdirectorovertheairconfigurationisalittledifferent
andiscoveredinChapter9.
AConfigurationwindowisavailableforboththeHBSandtheHSUstochangesettingwithout
necessarilydroppingservice.Neverthelesscaremustbeexercisedwhenchangingthem.By
wayofexample,changingantennaparametersforaHSUresultsinaHSUreset.Itisnecessary
howevertohavethisfunctionintheConfigurationwindowsinceitisrequiredtoinitiallyset
uptheunit.
TheHBSitselfmaybeconfiguredovertheair:Ascenarioforthisiswherethesectorisback
hauledbyonoftheHSUs.Therearenosignificantdifferencesbetweenthetwomethods,
howeversomecareisrequired.Ifforexample,youdeactivatetheHBSovertheair,youwill
lockyourselfoutofthesector.
RunningSpectrumViewfromtheHBSmanagerovertheair,willlockyououtfortheduration
oftheSpectrumViewtimeoutperiod.

ConfiguringaHBS
ConfigurationMenuButtons
OpentheConfigurationwindow.

RADWIN5000HPMPUserManual

Release3.5.50

81

System

TheBackupandRestorebuttonsprovideforbackupandrestoreoftheHBSsoftware.

Note

Abackup(fullorconfiguration)mayberestoredtoanotherHBSprovided
thattheproductIDsandrevisionlevelsofthesourceandtargetHBSsare
identical.TheyareshownintheHBSInventorywindow.
Inaddition,thesupportedbandsandAESversion(128or256)mustbethe
sameforthesourceandrestoredHBSs.

TheRefreshbuttonrestoresthecurrentwindowtoitspreviousstateabandoninganychanges
youmade,providedthatyoudidnotclickApplyorOK.
WewillworkthrougheachoftheConfigurationtabsinturnwithemphasisontabsor
featuresnotencounteredinthepreviouschapters.

System

Theseitemsareconveniencefields.NameandLocationaretypicallyenteredduringHBS
activation.YoumayliketochangeContacthere,notsetduringactivation.TheCoordinates
buttonopensthesamewindowasusedduringactivation.

RADWIN5000HPMPUserManual

Release3.5.50

82

AirInterface

AirInterface

ThispanelhassimilarfunctionalityasthecorrespondingwindowintheActivationWizard
(seeChapter6).ChangingtheSectorIDwillpercolatetoallregisteredHSUs.Itwillof
course,bepickedupbynewlyinstalledandregisteredHSUs.

TheonlywaytochangetheOperatingChannelisbydeactivationandreactivation.
ChannelBandwidthandChannelSelectionchangeswillallbesectorwide.
UseofAutomaticChannelSelectiononlymakessenseatconfigurationtime.Choosea
singlechannelbasedonwhatACSshows.UsetheSpectrumViewtool(Chapter24)to
helpyoumakeyourchoice.

TheAdvancedbar(shownopen)enablesyoutochooseThroughputModethatdetermines
howtheAdaptiveModulationmechanismworks.MaximumThroughput(default)shouldbe
chosenifthroughputismoreimportantthanhigherdelay.Conversely,ReducedLatency
minimizesdelayattheexpenseoflowerthroughput.

RADWIN5000HPMPUserManual

Release3.5.50

83

TxandAntenna

TxandAntenna
ThistabisavailableforboththeHBSandHSUs.Ithasthesamemeaninginbothcases.

FortheHBS,changesmadeheremayaffectlinkqualityandinthecaseofantennatype,cause
asectorresync.
ChangingtheantennatypeforanHSUwillcausearesynctothatsiteonly.

RADWIN5000HPMPUserManual

Release3.5.50

84

HubSiteSync[HSS]

HubSiteSync[HSS]

TheExternalPulseswhichmightbedetected,maycomefromacollocatedHBS,aRADWIN
2000ODUoraRADWINGSUconfiguredasHubSyncMaster.ToenableHSS,checkthe
Enabledcheckbox.

EnsurethatthecorrectOperationalstateisselectedinourexample,HubSiteClient
ContinueTx.ClickApplyorOKtoenableHSS.

HSSsupportforRADWIN5000HBSsismodeldependent

Note

RADWIN5000HPMPUserManual

Release3.5.50

85

Management

SeeHubSiteSynchronizationforfurtherdetailaboutHSS.

Management
IfyousettheIPandrelatedaddressescorrectly,thereshouldbelittletochangehere.

IPVersion
YoumayconfigurealinkforIPv4,IPv6orboth:

HerewechoosebothandentertheIPv6addresses:

RADWIN5000HPMPUserManual

Release3.5.50

86

Management

UsingbothIPversionsisusefulinconjunctionwithapplicationsthatdonotfullysupportIPv6.
HerearetheresultsofsettingIPv6addressesforbothsitesandenablingShowIPtoIPv6in
Preferences|Monitor:

Thethreesubwindows,TrapDestinations,VLANManagementandProtocoldialogsare
generictotheHBSnadtheHSUs(directorovertheair)andarediscussedbelow.

RADWIN5000HPMPUserManual

Release3.5.50

87

Management

TrapDestinations

TochangeatrapIPaddress:
1.Openanentrywithitseditbutton:

Thefollowingentrywindowisdisplayed:

2.EntertheTrapDestinationIPAddressandPort.ItcouldbetheIPaddressofthe
managingcomputer.Theeventslogwillbestoredattheaddresseschosen.
3.ForSecuritymodelyoumaychoosebetweenSNMPv1orSNMPv3.Thechoiceissite
dependent.IfyouchooseSNMPv1,youmayonlyenteranIPaddressandport
number.ForSNMPv3,youshouldsupplyausernameandpassword:

RADWIN5000HPMPUserManual

Release3.5.50

88

Management

4.ClickOKtosaveyourchoice.
Notethatforeachactivetrapdestination,theClearTrapDestinationbuttonisenabled:

VLANforManagement
ManagementVLANConfiguration

Figure81:VLANforManagement

Caution

VLANIDsareusedbyRADWINproductsinthreeseparatecontexts:
ManagementVLAN,TrafficVLANandEthernetRing.Itisrecommendedthat
youusedifferentVLANIDsforeachcontext.

VLANManagementenablesseparationofusertrafficfrommanagementtrafficwhenever
suchseparationisrequired.Itisrecommendedthateachmemberofasectorbeconfigured
withdifferentVLANIDsformanagementtraffic.(Thisreducesyourchancesofaccidentally
lockingyourselfoutofthesector.)

ToenableVLANformanagement:
1.InthewindowofFigure 81,checktheEnabledbox.
2.EnteraVLANID.Itsvalueshouldbebetween2and4094.
AfterenteringtheVLANID,onlypacketswiththespecifiedVLANIDareprocessed
formanagementpurposesbytheHBS/HSUODU.Thisincludesalltheprotocolssup
portedbytheODU(ICMP,SNMP,TelnetandNTP).UsingVLANformanagementtraf
ficaffectsalltypesofmanagementconnections(local,networkandovertheair).
3.EnteraPrioritynumberbetween0and7.

RADWIN5000HPMPUserManual

Release3.5.50

89

Management

TheVLANpriorityisusedforthetrafficsentfromtheODUtothemanagingcom
puter.
4.ChangetheVLANIDandPriorityofthemanagingcomputerNICtobethesameas
thoseofsteps2and3respectively.
5.ClickApplyorOK.
LostorforgottenVLANID
IftheVLANIDisforgottenorthereisnoVLANtrafficconnectedtotheODU,thenresetthe
relevantODU.
Duringthefirsttwominutesofconnection,theODUusesmanagementpacketsbothwith
andwithoutVLAN.YoumayusethisperiodtoreconfiguretheVLANIDandpriority.

SupportedProtocols
SupportedprotocolsareshowninFigure 82:

Figure82:Supportedprotocols
SNMPsupportispermanentlyenabled.YoumaychoosebetweenSNMPv1,SNMPv3orboth.
IfyouchooseSNMPv3,youwillbeofferedthefollowingcautionarymessage:

Forasectormanagedaspartofanetwork,directaccesstoaHBS/HSUusingTelnetis
consideredtobeasecuritybreach.Telnetaccessmaybeenabledordisabledbyclickingthe
Protocoltabandenabling/disablingTelnetaccessusingtheTelnetcheckbox.Similar
considerationsapplytoaccessviatheWebInterface.

ForfurtherdetailsaboutTelnetaccessseepage 856.
ForfurtherdetailsabouttheWebInterface,seeChapter25.

TelnetandWebInterfaceaccessmodeswhenavailable,aresitespecific.Ifforexample,you
wantTelnetaccessfromspecificsectormembers,youshouldenableitforthesesitesand
disableitelsewhere.

RADWIN5000HPMPUserManual

Release3.5.50

810

Management

Conversely,IftheTelnetorWebInterfaceaccessmodesposeageneralsecurityrisk,youmust
disablethemforeachsectormemberseparately.

MultiuserSupportunderSNMPv3
IfyouchoseSNMPv3orbothversions,youareaskedtologonagain:

ForthefirstlogonunderSNMPv3,useaspassword,theUserName,admin.Thereisone
changetothemainwindow.ThetitlebarnowshowstheSNMPCv3username:

Further,thereisanadditionalbutton,SNMPv3Users,intheManagementwindow:

RADWIN5000HPMPUserManual

Release3.5.50

811

Management

Usingthenewbuttonopensupthefollowingentrylist:

Tomakeanyofthefollowingchanges,youmustbeloggedonasuseradmin.TheSNMPv3
passwordsforadminandoperatorareasfollows:
Table81:SNMPv3predefinedusers
UserName

Password

Profile

admin

netwireless

ReadWrite

operator

netpublic

ReadOnly

ToaddanSNMPv3user:
1.Clicktherighthandediticononanyemptylineofthelist:

RADWIN5000HPMPUserManual

Release3.5.50

812

Management

2.AnEditwindowisdisplayed:

Figure83:AddorEditauser
3.Enterausernameandpassword.Confirmthepasswordasindicated.
4.ChooseaProfile:

ReadOnlyprovidesObserverlevellogonaccess.
ReadWriteprovidesOperatorlevellogonaccess
Disabledstorestheuserdetailsinthedatabaseforfutureuse.Itmustbe
changedtoReadOnlyorReadWritetobecomeusable.

5.ClickOKtoaccept.HereistheresultofaddingonemoreReadWriteuser,oneRead
OnlyUserandoneDisableduser:

RADWIN5000HPMPUserManual

Release3.5.50

813

Management

Figure84:SNMPv3userslist

Toeditanexistinguser:
1.Usethesameprocedureasabovetochooseauserforediting.Forillustration,wewill
correctthespellingofTelemansname:

2.Clicktheeditbutton:

3.Correctthespellingofthename:
RADWIN5000HPMPUserManual

Release3.5.50

814

Management

4.Enterandconfirmtheuserspassword:

5.ClickOKtofinish.ThechangewillbereflectedinthedisplayofFigure 84.
6.Usethesamemethodtochangetheusersprofile.

Note

Passwordsareneverdisplayedascleartext.Ifauserlooseshispassword,
theonlywaythatthesituationcanbecorrectedistodeletetheusername
andrecreatethesameusernamewithanotherpassword.

LoggingonasaSNMPv3User

TologoffasuseradminandlogonasaReadWriteprofileuser(Vivaldi):
1.Hereisthedefaultlogondialog:

RADWIN5000HPMPUserManual

Release3.5.50

815

Management

Figure85:DefaultSNMPv3logondialog
2.Intherighthandwindow,entertheusername(Vivaldi)andpassword.
3.ForaReadWriteprofileuser,youmaylogonasanyusertype(Observer,Operator,
Installer).Forexample,logonVivaldiasOperator.SinceVivaldibelongstotheRead
Writeprofile,inthelefthandwindow,useadminforthePasswordandleaveUser
Typeasis.(Ifnecessary,youcanusewirelessandInstaller,respectively.)

RADWIN5000HPMPUserManual

Release3.5.50

816

Management

Inthemainwindowweseetheusernameinthetitlebar:

TologonasaReadOnlyprofileuser(Handel):
1.InFigure 85,logonasHandelinsteadofVivaldi.
2.Onthelefthandside,setusertypetoInstallerandpasswordtowireless.
Inthemainwindowweseetheusernameinthetitlebarasfollows:

Theruleis,thattheloggedonprivilegelevelwillbethelowestoftheSNMPv3usertype
andtheRADWINManagerusertype.

RADWIN5000HPMPUserManual

Release3.5.50

817

Inventory

Inventory
Youmightliketocaptureorcopytheinformationhere:

TheInventoryinformationwillberequiredbyCustomerServiceshouldyourequire
assistance.

RADWIN5000HPMPUserManual

Release3.5.50

818

Security

Security
ThissectionappliestoboththeHBSandHSUsunlessstatedotherwise.

Figure86:SectorSecuritysettings
TheSecuritydialogenablesyoutochangetheLinkPasswordandtheSNMPCommunity
strings.IfyouhaveAES256Encryptionsupport,thecheckboxwillbeenabledattheHBS.
ThisitemdoesnotappearontheHSUConfigurationpanelatall.Fordetailsaboutconfiguring
andusingAES256,seeConfiguringAES256EncryptionSupport.

ChangingtheLinkPassword
Thisitemisavailableasfollows:

AtanisolatedHBS(NoactiveHSUs)
AtanisolatedHSU
NeverforanactiveHSU

Herearethedetails:

RADWIN5000HPMPUserManual

Release3.5.50

819

Security

Thedefaultpasswordiswirelessp2mp.Optionally,youcanchangethelinkpasswordas
explainedhere.

Tochangethelinkpassword:
1.OpentheSecuritytab(Figure 86).
TheChangeLinkPassworddialogboxopens.

UsetheHidecharacterscheckboxformaximumsecurity

Note

Figure87:ChangeLinkPassworddialogbox
2.Enterthecurrentlinkpassword(ThedefaultlinkpasswordforanewODUiswireless
p2mp).
IfyouhaveforgottentheLinkPassword,clicktheForgottenLinkPasswordbutton.
Thefollowingwindowisdisplayed:

Figure88:LostorforgottenLinkPasswordrecovery
FollowtheinstructionstousetheAlternativeLinkPassword,andclickOKtofinish.
YouarereturnedtothewindowinFigure 87above.Continuewiththenextstep.

RADWIN5000HPMPUserManual

Release3.5.50

820

Security

3.Enteranewpassword.
4.RetypethenewpasswordintheConfirmfield.
5.ClickOK.
6.ClickYeswhenaskedifyouwanttochangethelinkpassword.
7.ClickOKatthePasswordchangedsuccessmessage.

Note

Alinkpasswordmustcontainatleasteightbutnomorethan16char
actersexcludingSPACE,TAB,andanyof>#@|*?;.
RestoringFactoryDefaultsreturnstheLinkPasswordtowireless
p2mp.

RADWINManagerCommunityStrings
Inthissection,ODUmaybeeitheranHBSoranHSU.

Note
TheODUcommunicateswiththeRADWINManagerusingtheSNMPv1orSNMPv3protocol.
TheSNMPv1protocoldefinesthreetypesofcommunities:

ReadOnlyforretrievinginformationfromtheODU
ReadWritetoconfigureandcontroltheODU
TrapusedbytheODUtoissuetraps.

TheCommunitystringmustbeenteredatlogon.Youmustknowthepasswordandthe
correctCommunitystringtogainaccesstothesystem.Youmayhavereadonlyprivileges.Itis
notpossibletomanagetheODUifthereadwriteorthereadCommunityvaluesare
forgotten.AnewCommunityvaluemaybeobtainedfromRADWINCustomerServiceforthe
purposeofsettingnewCommunity.Youmustalsohaveavailabletheserialnumberorthe
MACaddressoftheODU.
ThereadwriteCommunitystringsandreadonlyCommunitystringshaveaminimumoffive
alphanumericcharacters.(bru1andbru4097arenotpermitted).Changingthetrap
Communityisoptionalandisdonebyclickingthecheckbox.

EditingSNMPv1CommunityStrings
Wheneditingthesestrings,bothreadwriteandreadonlycommunitiesmustbedefined.
Uponloggingonforthefirsttime,usethefollowingasthecurrentCommunity:

ForReadWriteCommunity,usenetman.
ForReadOnlyCommunity,usepublic.
ForTrapCommunity,usepublic
TochangeaCommunitystring:
1.TypethecurrentreadwriteCommunity(defaultisnetman).

RADWIN5000HPMPUserManual

Release3.5.50

821

Security

2.Choosethecommunitiestobechangedbyclickingthecheckbox.
3.TypethenewCommunitystringandretypetoconfirm.Acommunitystringmust
containatleastfiveandnomorethan32charactersexcludingSPACE,TAB,andany
of>#@|*?;."
4.ClickOKtosave.

EditingSNMPv3Passwords
Tocommencetheprocess,youmustenterthecurrentReadWriteCommunitypasswordas
showninthefirstfieldofFigure 89below.ChangetheReadWriteandReadOnlypasswords
asindicated.Apasswordmustbebetween8and31characterslong.Thesamecharacter
restrictionsfortheSNMPv1communitystringsalsoapplyhere.

Figure89:ChangingtheCommunityStrings/Passwords

ForgottenSNMPv1CommunityString
IfthereadwriteCommunitystringisunknown,analternativeCommunitykeycanbeused.
ThealternativeCommunitykeyisuniqueperODUandcanbeusedonlytochangethe
Communitystrings.ThealternativeCommunitykeyissuppliedwiththeproduct,andshould
bekeptinasafeplace.
IfboththereadwriteCommunityandthealternativeCommunitykeyareunavailable,then
analternativeCommunitykeycanbeobtainedfromRADWINCustomerServiceusingthe
ODUserialnumberorMACaddress.Theserialnumberislocatedontheproductlabel.The
serialnumberandtheMACaddressaredisplayedintheSiteConfigurationinventorytab.
WhenyouhavethealternativeCommunitykey,clicktheForgotCommunitybuttonandenter
theAlternativeCommunitykey(Figure 810).ThenchangethereadwriteCommunitystring.

RADWIN5000HPMPUserManual

Release3.5.50

822

DateandTime

Figure810:AlternativeCommunityDialogbox

DateandTime
SettingtheDateandTime
TheODUmaintainsadateandtime.Thedateandtimeshouldbesynchronizedwithany
NetworkTimeProtocol(NTP)version3compatibleserver.
DuringpoweruptheODUattemptstoconfiguretheinitialdateandtimeusinganNTPServer.
IftheserverIPaddressisnotconfiguredorisnotreachable,adefaulttimeisset.
WhenconfiguringtheNTPServerIPaddress,youshouldalsoconfiguretheoffsetfromthe
UniversalCoordinatedTime(UTC).Ifthereisnoserveravailable,youcaneithersetthedate
andtime,oryoucansetittousethedateandtimefromthemanagingcomputer.Notethat
manualsettingisnotrecommendedsinceitwillbeoverriddenbyareset,powerup,or
synchronizationwithanNTPServer.

Note

TheNTPusesUDPport123.IfafirewallisconfiguredbetweentheODUand
theNTPServerthisportmustbeopened.
Itcantakeupto8minutesfortheNTPtosynchronizetheODUdateand
time.

Tosetthedateandtime:
1.DeterminetheIPaddressoftheNTPservertobeused.
2.Testitforconnectivityusingthecommand(WindowsXPand7),forexample:
w32tm/stripchart/computer:216.218.192.202

RADWIN5000HPMPUserManual

Release3.5.50

823

DateandTime

Figure811:DateandTimeConfiguration
3.IfenteringanIPaddressfortheNTPServer,clickClear,andthenenterthenew
address.
4.SetyoursiteOffsetvalueinminutesaheadorbehindGMT1.
5.Tomanuallysetthedateandtime,clickChangeandeditthenewvalues.

1. GreenwichMeanTime
RADWIN5000HPMPUserManual

Release3.5.50

824

EthernetServiceConfiguration

Figure812:ChangeDateandTime
6.ClickOKtoreturntotheConfigurationdialog.

EthernetServiceConfiguration

Figure813:SettingEthernetservices

RADWIN5000HPMPUserManual

Release3.5.50

825

EthernetServiceConfiguration

HBSAgingTime
TheHBSworksinBridgeMode.InBridgemodetheODUperformsbothlearningandaging,
forwardingonlyrelevantpacketsoverthesector.TheagingtimeoftheODUisbydefault,300
seconds.

EthernetPortsConfiguration
TheODUEthernetportmodeisconfigurableforlinespeed(10/100/1000BaseT)andduplex
mode(halforfullduplex).
Linespeed1000BaseTisonlyavailableiftheHBSisconnectedtoAGbEPoEdevice.

AnAutoDetectfeatureisprovided,wherebythelinespeedandduplexmodearedetected
automaticallyusingautonegotiation.Usemanualconfigurationwhenattachedexternal
equipmentdoesnotsupportautonegotiation.ThedefaultsettingisAutoDetect.
TheiconnexttotheCRCerrorcountmaybeclickedtoresetthecountertozero.

Caution

Youshouldnotreconfiguretheportthatisusedforthemanagingcomputer
connection,sinceawrongconfigurationcancauseamanagement
disconnectionorEthernetservicesinterruption.

ToconfiguretheEthernetMode:
IntheEthernetPortsConfigurationpane,usethedropdownmenutochoosethe
requiredmode.

TransmissionRatio(TxRatio,AsymmetricAllocation))
TheTransmissionRatioshowstheallocationofthroughputbetweendownlinkanduplink
trafficattheHBS.TheTransmissionRatioisnotonlysectorwide:IfyouuseHSS(Chapter13)
tocollocatedseveralHBSs(tocoveradjacentsectors),theymustallusethesame
TransmissionRatio.

RADWIN5000HPMPUserManual

Release3.5.50

826

EthernetServiceConfiguration

Figure814:HBSCollocatedclientorindependentunit
IfitisanHSSmaster,youwillseesomethinglikethis:

Figure815:HBSCollocatedmaster
Movingtheslidertotherightinstages,yieldsthefollowing:

TheeffectiveavailablerangeforAsymmetricallocationisdeterminedbychannelbandwidth
asshownaswellaslinkdistance.Inthiscontext,linkisacollocatedHBSorRADWIN2000
ODU.

QoSConfiguration
ToinstallandusetheEthernetQoSfeature,seeChapter21.

RADWIN5000HPMPUserManual

Release3.5.50

827

Nomadic

Advanced:Broadcast/MulticastFloodingProtection
Broadcast/MulticastFloodingProtectionprovidesameasureofprotectionbylimiting
multicastandbroadcastpacketstomomorethan12.5%ofavailablecapacity.

Youmaywishtouncheckthisitemifyourapplicationisbasedonmulticast/broadcast
packetsforexample,videosurveillanceusingmulticastdownlink,orvideoconferencing
usingmulticastuplink.

Nomadic

Seepage 627.

RADWIN5000HPMPUserManual

Release3.5.50

828

Operations

Operations
ThissectionappliestobothHBSsandHSUs.

RevertingtoFactorySettings

Figure816:RestoreFactorySettingsandLicenseActivation
ClickingtheRestoreDefaultsbuttonopensthefollowingselfexplanatorydialog:

RADWIN5000HPMPUserManual

Release3.5.50

829

Advanced:FalseRadarMitigationforHBS

LicenseActivation
YoumayaddadditionalbandsorcapacityusingthelicenseActivationfacility.Additional
bands(ifavailable)areobtainedusingtheChangeBandfunction,describedbelow.Capacity
upgradeisdescribedinChapter22.
Forasingleband,justenterthesuppliedlicenseKeyandclickActivate.Ifyouhavealistof
them(atextfile)youwillneedtousetheLicenseFileoption.
InsomeinstancesitmayinvolvepurchasingtherelevantlicensefromRADWIN.Youshould
contactCustomerServicefordetails.Youwillfindthetechnicalstepsrequiredtoobtainand
installextrabandsonpage 851.

Advanced:FalseRadarMitigationforHBS

Thistabisonlyvisibleif

YouareusingaRegulationrequiringRadarChannelAvoidanceand
YouareloggedonasInstaller

Forthisrelease,thisfeatureattheHBS,isonlyrelevanttothe5.3GHzETSIband.
ConfigurationofFalseRadarMitigationiscoveredinChapter19.

HSUConnectionTable
FromtheHBSbuttonbar,clicktherighthandbuttonfollowedbyHSUConnectionTable.

Thefollowingtableisdisplayed:

RADWIN5000HPMPUserManual

Release3.5.50

830

ConfiguringanHSUfromtheHBSMainWindow

Figure817:HSUIntercommunicationConnectionTable
Thegreenshadedsquaresshowintercommunicatingelementswithinthesector.MNGrefers
tomanagementtrafficwhichshouldalwaysbeopenbetweenHSUsandtheHBS.LANrefers
toservicetrafficbetweentheHBSandtheHSUs.Asshown,thetwoHSUsmaynot
communicatebetweenthemselves.Clickingthetopwhitesquarewouldenable
communication(viatheHBS)betweenthem.
YoumayinfactdisablealltrafficbetweentheHBSandtheHSUsandrestoreitusingthis
device.

ConfiguringanHSUfromtheHBSMain
Window
RightclickanHSUforitscontextmenuandclickConfiguretoopentheHSUConfiguration
window.

ConfigurationMenuButtons

RADWIN5000HPMPUserManual

Release3.5.50

831

ConfigurationMenuButtons

TheBackupandRestorebuttonshavethesamefunctionalityasthecorrespondingbuttons
fortheHBS.TheyprovideforbackupandrestoreoftheHSUsoftware.

Note

Abackup(fullorconfiguration)mayberestoredtopanotherHSUprovided
thattheproductIDsandrevisionlevelsofthesourceandtargetHSUsare
identical.
Inaddition,thecapacityandsupportedbandsmustbethesameforthe
sourceandrestoredHSUs.

TheBuzzerbuttonmaysetormutethebuzzer.

TheAutopositionmeansthattheBuzzerwillgivethebeepsshowninFigure 451during
installationoruponsyncloss.
TheAdvancedAutopositionmeansthatinaddition,thebuzzerwillbeepcontinuouslyat
differentratesuponsyncloss,antennamisalignmentandothereventsforuptotwominutes
followingrestorationofsync.
RecallthatthemainuseofthebuzzertoneisforHSUantennaalignment.
TheRefreshbuttonrestoresthecurrentwindowtoitspreviousstateabandoninganychanges
youmade,providedthatyoudidnotclickApplyorOK.
WewillworkthrougheachoftheConfigurationtabsinturn:

RADWIN5000HPMPUserManual

Release3.5.50

832

System

System

Figure818:HSUConfigurationwindow(HBS)
Theseitemsareconveniencefields.Theyaretypicallyenteredduringregistration.

RADWIN5000HPMPUserManual

Release3.5.50

833

Tx&Antenna

Tx&Antenna

Figure819:HSUConfigurationSettingantennatypeandparameters
TheremarksaboutchangingtheHBSparametersalsoapplyhere.Changingtheantennatype
willcausearesyncbetweentheHSUandtheHBS.

RADWIN5000HPMPUserManual

Release3.5.50

834

Management

Management

Figure820:HSUConfigurationIPaddresses
ThefunctionalityisidenticalasthatfortheHBS.

RADWIN5000HPMPUserManual

Release3.5.50

835

Inventory

Inventory

YoushouldnotethedetailsforeachHSU.

RADWIN5000HPMPUserManual

Release3.5.50

836

Security

Security

YoumaychangetheSNMPcommunitystringsonlyfortheHSUfromhere.Youcannotchange
theLinkpasswordfromanHSU.

RADWIN5000HPMPUserManual

Release3.5.50

837

Date&Time

Date&Time

ThefunctionalityisidenticalasthatfortheHBS.

RADWIN5000HPMPUserManual

Release3.5.50

838

Ethernet

Ethernet
EthernetconfigurationforaHSUfollowsthesamegeneralpatternasthecorrespondingtab
fortheHBSbutwithimportantdifferences.

EthernetPortsConfiguration
ThisitemissameforallPoEpoweredHSUsandtheHBS.Seepage 826.FortheSU2ACs(AC
poweredHSUs)EthernetPortsConfigurationpanelisdifferent:

TheODUentryisdisabled;onlytheLANandPoE(out)portsareavailableforconfiguration:
TheLANporthastheseoptions:

RADWIN5000HPMPUserManual

Release3.5.50

839

Ethernet

ThePoEportoffersthefollowingoptions:

Typically,avideocameraisattachedtothePoEport.Thelasttwooptionprovidebasic
cameramanagementfunctions.The
performanceinformation:

buttonnexttothePOElabeloffersbasicPoE

MaximumInformationRate
TheMaximumInformationRate(MIR)wasinitiallysetduringHSURegistration.Youmay
changeithere.Ifyouchangeit,theHSUcarddisplaychanges.HereisanexampleusingHSU
Mozart@HFU.01.02:

Thecardchangesasfollows:

RADWIN5000HPMPUserManual

Release3.5.50

840

Nomadic

NoticethelefthandorangebarsindicatingtheDownlinkandUplinkMIRandthevertical
orangelinesintheThroughputbarsshowingtheupperlimit.

VLANConfiguration
ForTrafficVLANconfiguration,seeChapter18.

QoSConfiguration
QoSconfigurationisdescribedinChapter21.

Nomadic

YoucannotchangeafixedHSUtoanomadicHSUherewithoutpriorderegistration.Fora
nomadicHSU,youmaychangeitsoperatinglevelorevenrevertittoafixedHSU:

RADWIN5000HPMPUserManual

Release3.5.50

841

Nomadic

RADWIN5000HPMPUserManual

Release3.5.50

842

Operations

Operations

ThisfunctionalityisidenticaltothatfortheHBS.

Advanced:FalseRadarMitigation

Thistabisonlyvisibleif

YouareusingaRegulationrequiringRadarChannelAvoidanceand
YouareloggedonasInstaller

Forthisrelease,thisfeatureforHSUs,isrelevanttothe5.3GHzETSIandthe5.4GHzFCC/IC
bands.
RADWIN5000HPMPUserManual

Release3.5.50

843

ReplacinganHSU

ConfigurationofFalseRadarMitigationiscoveredinChapter19.

ReplacinganHSU
AdefectiveHSUmaybereplacedbyanotherHSUbelongingtothesectorprovidedthatthe
replacementisnotregistered.Hereisatypicalscenario:

Figure821:Unit10.104.50.1down;unit10.104.50.3available,notregistered
Sincethereplacementprocedureisaratherdelicateprocess,wewillstepthroughitwitha
detailedexamplebasedonthescenarioinFigure 821.

ToreplaceadefectiveHSU:
1.Rightclickthedefectiveunitforitscontextmenu:

Ithasanewitem:Replace.
2.ClickReplace.YourareofferedalistofHSUsavailableasreplacements.Inour
examplethereisone:10.104.50.3

RADWIN5000HPMPUserManual

Release3.5.50

844

ReplacinganHSU

3.Selecttherequiredunitbyclickingonit.

4.ClickOK.Youareaskedtoconfirmbeforeproceeding:

5.ClickOKagain.Youreceivefurtherconfirmation:

Hereisthefinaloutcome:

RADWIN5000HPMPUserManual

Release3.5.50

845

UpdatingHSUServices

Noticethat10.104.50.3hasreplaced10.104.50.1inheritingmostofitssettings.

Note

TheIPaddressofthereplacementunitisnotchanged.Toensurethatall
10.104.50.1trafficactuallygetstothenewunit,youshouldalsochangeits
IPaddresstothatoftheoriginalunit,10.104.50.1.

UpdatingHSUServices
ChoosingUpdateServicesfromanHSUcontextmenuorclicking
fromtheHSUbutton
baropenstheRegistrationwindow.YoumayusethistoswitchtheHSUbetweenSpatial
Multiplexing,DiversityandAutomode.YoumayalsochangetheHSUtimeslotallocation.

SuspendinganHSU
Youmaybreakthelink(causeasyncloss)toanunregisteredHSUforafixedamountoftime.
Hereisthescenario:

HSU10.104.50.1isnotregistered.
RADWIN5000HPMPUserManual

Release3.5.50

846

ChangingtheSectorBand

TosuspendanunregisteredHSU:
1.ClickSuspendinitscontextmenu.Youarerequestedtoenterasuspendduration.

2.ChooseasuspendtimeandclickOK.Duringthesuspendduration,theHSUwillbe
deletedfromtheHBSMainWindowHSUpanel.TheHSUreturnstothemaindisplay
withresumptionofsync.

ChangingtheSectorBand
ChangingtheBandinuseisalwayscarriedoutatthesectorlevel(notperinstalledODU).To
theSectorBandyoumustbeloggedontotheHBSasInstaller.InInstallermode,theright
handbutton,

ontheBaseStationbuttonbarhasanextrafunction,ChangeBand.

TochangetheSectorBand:
1.ClickChangeBand.AlistofavailableBandsisdisplayed:

RADWIN5000HPMPUserManual

Release3.5.50

847

ChangingtheSectorBand

Figure822:ChangeorAddBands
2.SelecttherequiredBandandclickOK.Forourpurposes,wechoose5.7205.960GHz
Universal.Thebandishighlightedandrightbuttonisenabled.

RADWIN5000HPMPUserManual

Release3.5.50

848

ChangingtheSectorBand

Figure823:Add/ChangeBanddialog
3.Clicktherightbutton.Thefollowingwindowopens:

RADWIN5000HPMPUserManual

Release3.5.50

849

ChangingtheSectorBand

4.Hereyoumaychosetheworkingchannelbandwidthandchannelselectionasinthe
activationprocess.ClickOKtoacceptyourchoice.Youarereturnedtothedisplayin
Figure 823.
5.ClickOKagain.Thefollowingcautionarymessageisdisplayed:

6.ClickYestocontinue.Afterashortdelay,youareofferedafinalconfirmation:

RADWIN5000HPMPUserManual

Release3.5.50

850

ChangingtheSectorBand

7.ClickOK.Asectorresyncfollows.Hereisthefinalresult:

Havingsetthechannelbandwidthandoperatingchannelsearlier,thereisnoneed
fordeactivationandreactivation.
YoumayalsoaddnewBandsbyclickingtheAddBandsbutton.Thereareseveralprovisosto
this:

AdditionalBandsmustbeavailableforyourhardware
SuchadditionalBandsmustbeavailablewithintheframeworkofyourlocalregulations

TheforegoingappliestobothregulatedandunregulatedBands.

Toobtainandinstalladditionalbands:
1.MakealistofODUserialnumbersforallHBSsandallHSUstoreceiveadditional
bands.Thelistshouldbeasimpletextfile,oneserialnumberperline.(Theserial
numbersarelocatedonthestickersontheODUs.)
2.AsInstaller,openthewindowofFigure 822above,andclickAddBands.The
followinginstructionpanelisdisplayed:

RADWIN5000HPMPUserManual

Release3.5.50

851

ChangingtheSectorBand

Figure824:AddBandsInstructionsPanel
TheserialnumbersdisplayedrelatetotheODUsinthesector.ClickCopytoClip
board.
3.Thisstepappliesonlyifyouhaveadditionaluninstalledunits:
Beforeproceedingtostep2inFigure 824,openyourownlistinaplaintexteditor.If
thedisplayedserialnumbersareinthelist,selectyourlistandcopyitalltotheclip
board.Otherwiseappendtheclipboardcontentstoyourlist.Selectthewholelist
andsaveittotheclipboard.
4.Nowcarryoutsteps2to5inFigure 824.Step2willtakeyoutoaWebpage,which
containsaformlikethis:

RADWIN5000HPMPUserManual

Release3.5.50

852

ChangingtheSectorBand

5.Fillouttherequesteddetails.RemembertoterminatethedialogbyclickingtheGet
Keybutton.
6.Theresultsofyourrequestwillbedisplayedwithfurtherinstructions.

RADWIN5000HPMPUserManual

Release3.5.50

853

ConfiguringAES256EncryptionSupport

Afewminuteslater,youshouldreceiveanemail,containinginitsbody,alistof
licensekeys.

Note

YoumayseeerrormessagesintheStatusColumnsuchasBandnot
supportedorSerialnotfound.Supportedbandstypicallyreflectyourlocal
regulations.CheckmissingserialnumberswithRADWINCustomerService.

7.CopyandPastethelicensekeysintoaplaintextfileandsaveittoasafeknownplace.
8.OpentheConfigure|Operationstab(Figure 816).ChecktheLicenseFilebuttonand
navigatetothefileyousavedinthelaststep.
9.ClickActivate.ThenexttimeyouentertheChangeBandstab,thenewbandswillbe
available.

ConfiguringAES256EncryptionSupport
AES256supportisperHSUbutenabledfromtheHBS.

ToenableAES256Encryptionsupportforasector:
1.EnsurethattheHBSishardwarereadyforAES256:FromtheHBSConfigurationbut
ton,opentheInventorypageandcheckthatthehardwareversionis9orhigher.
Openatextfileandcopy/pastetheserialnumberoftheHBStoit.
2.DeterminewhichHSUsrequireAES256support.FromtheInventorypageforeach
HSU,checkthatthehardwareversionis9orhigher.Copy/pastetheserialnumberof
theHSUtothetextlist,oneserialnumberperline.Alternatively,usethecapture
buttoninlistmodeattheHBStocopypastealistofHSUs.

Inanyevent,youmuststillcheckthehardwarelevelofeachlistedHSU.
3.Savethetextfileandsendittoyourequipmentsupplierwithyourlicensepurchase
order.
4.Youwillreceivebyreturnemailatextattachmentshowingserialnumberandlicense
key.Savethefiletoaknownsafelocation.
5.AttheHBS,opentheConfiguration|Operationstab(Figure 816).ChecktheLicense
Filebuttonandnavigatetothefileyousavedinthelaststep.

RADWIN5000HPMPUserManual

Release3.5.50

854

ConfiguringAES256EncryptionSupport

6.ClickActivate.YocanconfirmactivationbyopeningtheSecuritytab.TheAES265
checkboxisavailable(Figure 86).CheckittocommenceAES256Encryption.
YoucanconfirmAES256supportperODUbylookingattheEncryptioniconatthebottom
righthandcornerofthemainwindowasshowninthefollowingtables:
Table82:AESIndicatorsforanHBS
AESLevel
Supported

HBSEncryptionIcon

128
256
Table83:AESIndicatorsforanHSU
AESLevel
Supported

LicensedforAES256 HSUEncryptionIcon

128

N/A
No

256
Yes
Inaddition,theSecuritytabonanyHSUConfigurationwidow(fromtheHBSordirectlogon)
willindicatewhenappropriate,thatAES256isenabled:

RADWIN5000HPMPUserManual

Release3.5.50

855

ConfigurationwithTelnet

AES256supportforlicensedHSUsisimmediateandglobaleitherall
licensedHSUsareAES256enabledornone.

Note

ConfigurationwithTelnet
TelnetAccesstotheHBS
ATelnetterminalcanbeusedtoconfigureandmonitortheRADWIN5000HPMP.
TostartaTelnetsessionontheHBS,usetelnet<ODU_IP>.
Forexample,ifyourunTelnetasfollows,
telnet10.104.50.200
youwillbeaskedforausernameandpassword.
TheTelnetlogonusernameisthepasswordthatyouusedtoentertheRADWINManager
(forexample,thedefault:admin).TheTelnetpasswordisthecorrespondingCommunity
string(default:netman).

RADWIN5000HPMPUserManual

Release3.5.50

856

TelnetAccesstotheHBS

Figure825:TelnetsessionlogontotheHBS
AReadOnlyCommunitystringallowsyoutousedisplaycommandsonlywhereasaRead
WriteCommunitystringallowsyoutousedisplaycommandsandexecutesetcommands.
SupportedHBSTelnetcommandsareshowninTable 84toTable 86.
Table84:HBSTelnetDisplayCommands
Command

Explanation

displayinventory

DisplaysODUproductname,Name,Location,
hardwareandsoftwarerevisions,uptime,MAC
address.

displaymanagement

DisplaysIP,subnet,Gateway,Trapstable

displaylink<param:all,reg,unreg>

DisplaysallstaticdetailsaboutthesectororHSU

displayethernet

DisplaysPorttable(State,Statusandaction)

displayethernet_errors

DisplaysCablestatistics

displayntp

DisplaysTime,ServerandOffset

displayPM<interface:AIR,LAN1>
<interval:current,day,month>

Showstheperformancemonitortablesforeach
interfaceaccordingtouserdefinedmonitoring
intervals

displaybands

Displaysavailablebands

RADWIN5000HPMPUserManual

Release3.5.50

857

TelnetAccesstotheHBS

Table85:HBSTelnetSetImmediateCommands
Command

Explanation

setip<ipaddr><subnetMask>
<gateway>

SettheODUIPaddress,subnetmaskandgateway.
TheusermustresettheODUafterthecommand
completion

settrap<index:110><ipaddr>
<port:065535>

Setaspecifictrapfromthetrapstable(e.g.settrap3
192.168..101162)

setreadpw<oldpasswd><passwd>

Setthereadaccesspassword(ReadCommunity)

setwritepw<oldpasswd><passwd>

Setthereadwriteaccesspassword(ReadWrite
Community)

settrappw<oldpasswd><passwd>

SetthetrapCommunitystring

settpc<power:Valuebetween
minimalTxpower,andmaximalTx
power>

SettheODUTxPower.Ifawrongvalueisentered,
bothminandmaxvaluesshallbedisplayedinthe
errorreply

setname<newname>

Setthenameofthelink

setlocation<newlocation>

Setthenameofthelocation

setcontact<newcontact>

Setthenameofthesitemanager

setethernet<port:LAN1>
<mode:AUTO,10H,10F,100H,100F,D
ISABLE>

SetthemodeandspeedoftheEthernetport

reboot

ResetstheODU.Theuseriswarnedthatthe
commandwillresettheODU.AnewTelnetsessionto
theODUmaybeopenedaftertheresetiscomplete.

help

Displaystheavailablecommands

Table86:HBSTelnetSetCommandsrequiringReset
Command

Explanation

setsecId<SectorID>

SetnewsectorIDResetrequired.

RADWIN5000HPMPUserManual

Release3.5.50

858

TelnetAccesstotheHSU

TelnetAccesstotheHSU
TheprocedureisthesameasfortheHBS.

Figure826:TelnetManagementwindowHSU
SupportedHSUTelnetcommandsareshowninTable 87toTable 89.
Table87:HSUTelnetDisplayCommands
Command

Explanation

displayinventory

DisplaysODUproductname,Name,Location,
hardwareandsoftwarerevisions,uptime,MAC
address.

displaymanagement

DisplaysIP,subnet,Gateway,Trapstable

displaylink

DisplaysallstaticdetailsabouttheHSU

displayethernet

DisplaysPorttable(State,Statusandaction)

displayethernet_errors

DisplaysCablestatistics

displayntp

DisplaysTime,ServerandOffset

displayPM<interface:AIR,LAN1>
<interval:current,day,month>

Showstheperformancemonitortablesforeach
interfaceaccordingtouserdefinedmonitoring
intervals

displaybands

Displaysavailablebands

RADWIN5000HPMPUserManual

Release3.5.50

859

TelnetAccesstotheHSU

Table88:HSUTelnetSetImmediateCommands
Command

Explanation

setip<ipaddr><subnetMask>
<gateway>

SettheODUIPaddress,subnetmaskandgateway.
TheusermustresettheODUafterthecommand
completion

settrap<index:110><ipaddr>
<port:065535>

Setaspecifictrapfromthetrapstable(e.g.settrap3
192.168..101162)

setreadpw<oldpasswd><passwd>

Setthereadaccesspassword(ReadCommunity)

setwritepw<oldpasswd><passwd>

Setthereadwriteaccesspassword(ReadWrite
Community)

settrappw<oldpasswd><passwd>

SetthetrapCommunitystring

setbuzzer
<mode:0=OFF,1=AUTO,2=ON>

Setthebuzzermode

settpc<power:Valuebetween
minimalTxpower,andmaximalTx
power>

SettheODUTxPower.Ifawrongvalueisentered,
bothminandmaxvaluesshallbedisplayedinthe
errorreply

setname<newname>

Setthenameofthelink

setlocation<newlocation>

Setthenameofthelocation

setcontact<newcontact>

Setthenameofthesitemanager

setethernet<port:LAN1>
<mode:AUTO,10H,10F,100H,100F,D
ISABLE>

SetthemodeandspeedoftheEthernetport

reboot

ResetstheODU.Theuseriswarnedthatthe
commandwillresettheODU.AnewTelnetsessionto
theODUmaybeopenedaftertheresetiscomplete.

help

Displaystheavailablecommands

Table89:HSUTelnetSetCommandsrequiringReset
Command

Explanation

setsecId<SectorID>

SetnewsectorIDResetrequired.

RADWIN5000HPMPUserManual

Release3.5.50

860

Chapter9:

DirectHSUConfiguration
ScopeofthisChapter
DirectmanagementofanHSUmaybecarriedoutbyaLANconnectiontoamanaging
computer(onsite)orovertheair(fromtheHBSsite).
ThereareseveraldifferencesintheconfigurationfunctionalityforadirectlymanagedHSU
comparedtothemethodofChapter8dependingonwhethertheHSUisregisteredtoaHBS,
unregisteredornotamemberofanysector.
WhereconfigurationfunctionisidenticalunderdirectconnectionandthroughtheHBS,we
willnotrepeatthedetails,whichmaybeseeninChapter8.

ConfiguringanHSU
LogontotheHSUeitherdirectlyorovertheairasshowninChapter5.ForaregisteredHSU,
youwillseeadisplaylikethis:

RADWIN5000HPMPUserManual

Release3.5.50

91

ConfiguringanHSU

Figure91:DirectorovertheairconnectiontoaregisteredHSU
IfyouenabledRSSExtendedView(seeEnableRSSExtendedView),thenthecenterpartof
thedisplaylookslikethis:

Figure92:RegisteredHSUextendedview
ForanunregisteredHSU,thethroughput(Tput)fieldsandtheSectorIDfieldwouldbe
empty.
IftheHBSisdeactivated,ortheHSUisstandaloneyouwillseeadisplaylikethis:

RADWIN5000HPMPUserManual

Release3.5.50

92

ConfigurationMenuButtons

Figure93:DirectconnectiontoastandaloneHSUoutofthebox
Inwhatfollows,weconfigurearegisteredHSUunlessspecificallyspecifiedotherwise.

ConfigurationMenuButtons

TheBackupandRestorebuttonshavethesamefunctionalityasthecorrespondingbuttons
fortheHBS.TheyprovideforbackupandrestoreoftheHSUsoftware.

Note

Abackup(fullorconfiguration)mayberestoredtoanotherHSUprovided
thattheproductIDs,revisionlevelsandcapacityofthesourceandtarget
HSUsareidentical.TheyareshownintheHSUInventorywindow.

TheBuzzerbuttonmaysetormutethebuzzer.

RADWIN5000HPMPUserManual

Release3.5.50

93

AirInterface

RecallthatthebuzzertoneisprimarilyusedforHSUantennaalignment.
TheRefreshbuttonrestoresthecurrentwindowtoitspreviousstateabandoninganychanges
youmade,providedthatyoudidnotclickApplyorOK.
TheconfigurationtabsheredifferfromtheHSUconfigurationtabsundertheHBSTableview
inonerespect:ThereisanAirInterfacetab,whichvariesinfunctionality,dependingon
whethertheHSUisregisteredornot.

AirInterface

Figure94:HSUConfig.AirInterfaceforRegisteredfixedHSU

RADWIN5000HPMPUserManual

Release3.5.50

94

AirInterface

ForaregisteredHSUthiswindowisforinformationonly.Foranunregisteredor
unsynchronizedfixedHSU,theSectorIDfieldwillbeblankorthelastSectorIDusedand
editableandtheChannelBandwidthfieldwillbesettodefaultandactive:

Figure95:HSUConfig.AirInterfaceforstandalonefixedHSU
ForanomadicHSUoraHMU,theAirInterfacedisplayisdifferent.First,theSectorIDis
replacedbytheNetworkID.ForaregisteredHSU,neithertheNetworkIDorCBWcanbe
touched:

Figure96:HSUConfig.AirInterface,registerednomadicHSUorHMU
ForanunregisteredorunsynchronizedHSU,youmayeditbothofthesefields:

Figure97:HSUConfig.AirInterface,standalonenomadicHSUorHMU
UsethisfeaturetoswitchanomadicHSUorHMUtoadifferentnetwork.

RADWIN5000HPMPUserManual

Release3.5.50

95

AirInterface

WherehasmyHSUgone?
SupposethatyouinstalledtwocollocatedHBSswithcontiguoussectors.Itispossiblethatan
HSUlocatedclosetothecommonsectorboundarymaydiscoverthewrongHBS.AHSUcan
beforcedacrosstoanotherHBSbychangingitsSectorIDtothatoftherequiredHBS.To
switchanHSUtoanotherHBS,makesurethatitisunregistered.Youwillneedtologontoit
directlyandgettotheAirInterfacewindow:

Figure98:HSUConfig.AirInterfaceUnregisteredHSU
EntertheSectorIDoftherequiredHBSandclickOK.TheHSUshouldthendiscoverthe
requiredHBS.

RADWIN5000HPMPUserManual

Release3.5.50

96

Security

Security

YoumayonlychangetheSNMPcommunitystringsoveradirectorovertheairconnection.
YoucanchangetheLinkPasswordforanunsynchronizedHSU.Otherwisethefunctionalityis
thesameasinpage 837.

Advanced:FalseRadarMitigation

Thistabisonlyvisibleif

YouareusingaRegulationrequiringRadarChannelAvoidanceand
YouareloggedonasInstaller

Forthisrelease,thisfeatureforHSUs,isrelevanttothe5.3GHzETSIandthe5.4GHzFCC/IC
bands.
ConfigurationofFalseRadarMitigationiscoveredinChapter19.

RADWIN5000HPMPUserManual

Release3.5.50

97

Chapter10:

SmartBandwidth
Management
WhatisSmartBandwidthManagement
SmartBandwidthManagement(SBM)enablesbusylinkstoutilizeunusedtimeslotresources
fromrelativelyidlelinks.ItappliestofixedandnomadicHSUs.Itoffers

Peakratesofover100%ofassuredstaticallocationforbusylinks
Enhancedoverallsectorutilization
Dynamicbandwidthallocationtomaximizeserviceproviderthroughputandadhereto
customerSLAs

Toachievebestsectorperformance,eachHSUisallocatedseparateuplinkanddownlinktime
slots.
DownlinktrafficisfullyunderHBScontrol,sothatitcanallocateanyunuseddownlinktime
slotswhetherallocatedornottoabusylink.Thebusylinkmayoperateatanextremelyhigh
peakrates,1000%utilizationnotbeinguncommon.
Uplinktrafficisunpredictable.Again,inthecaseofabusylinkwithotherlinksrelativelyidle,
theHBSwillallocateextrauplinktimeslotstothebusylinkfromfreepoolonly.Ifallofthe
uplinktimeslotsareallocated,thenSBMwillnotoperateintheuplinkdirection.
Theallocationofuplinkanddownlinktimeslotsbecomesanetworkpolicyissue.For
example,ifalltheHSUsprovideregularinternetservice,itmightbeadvisabletogiveeach
oneminimumtimeslotsinbothdirections(subjecttothe63timeslotmaximumineach
direction)andallowtraffictodynamicallydeterminetimeslotutilization.Alternatively,ifthe
HSUsareusedforbackhaul,theminimumnumberoftimeslotsineitherdirectionshouldbe
allocatedtomeetdefinedservicerequirements(suchasaSLAs).
TheRADWINManagerprovidesfacilitiestoconfigureseparateuplinkanddownlinktime
slots.Itfurthermonitorsperformance,providingtabularandgraphicutilizationstatistics.

RADWIN5000HPMPUserManual

Release3.5.50

101

ScopeofthisChapter

ScopeofthisChapter
UseofSmartBandwidthManagement(SBM)asatooltoenhanceresourceutilization
involvesnetworkmanagementissuesbeyondthescopeofaUserManual.Whatwewilldo
here,isshowhowSBMisconfiguredanddemonstrateseveralbasicscenarios.Ourintentisto
getyoustartedwithSBMbyassistingyoutodevelopyourownintuitionandnetworking
skillssettinguphighlyresourceefficientsectors.
ThefirstpointtokeepinmindisthattheSBMmechanismisalwaysactiveintheHBS.Itsnot
somethingyoucanswitchonorswitchoff.
Theissuehereishowtogetthebestoutofit.

TerminologyandConcepts:Recapitulation
Itisimportantbothinfollowingthediscussionbelow,andviewingtheRADWINManager
Utilizationwindowstoremember:

DownlinktrafficisdatatransferfromanHBStoanHSU
UplinktrafficisdatatransferfromanHSUtoanHBS
TheHBSallocatestimeslotstosectorHSUsinroundrobinfashiontoeffecttimeshar
ing.Thereareseparatesetsof64timeslotsforeachoftheuplinkanddownlinkdirec
tions.OnetimeslotineachdirectionisreservedforSBMmanagementleaving63in
eachdirectiontobeallocatedtosectorHSUs.Theuplinkanddownlinkallocationsare
independentandthereforeseparatelyassignable.
ForeachfixedornomadicHSU,Assuredthroughputisdeterminedbytheactualnum
beroftimeslotsallocatedtoitineitherdirection.Peakthroughput(higherthan
Assuredthroughput)maybeachievedbyallocatingunuseddownlinktimeslotsor
unallocateduplinktimeslotstoverybusyHSUs.
Timeslotallocationistheonlymechanismavailableforutilizationmanagement.
ManualtimeslotallocationforafixedHSUiscarriedoutduringregistrationorSer
viceupdate:

RADWIN5000HPMPUserManual

Release3.5.50

102

TerminologyandConcepts:Recapitulation

Figure101:Service(Timeslots)updateforafixedHSU

ManualtimeslotallocationfornomadicHSUsiscarriedoutfromtheHBSConfigura
tionwindow:

RADWIN5000HPMPUserManual

Release3.5.50

103

HowSBMWorks

Figure102:Service(Timeslots)updateforanomadicHSUs

HowSBMWorks
DownlinktrafficisfullyunderHBScontrol,sothatitcanallocateanyunuseddownlinktime
slotstoaverybusylink,whetherallocatedorinfreepool.Thebusylinkmayoperateatan
extremelyhighthroughput,1000%utilizationnotbeinguncommonaswillbeseeninan
examplebelow.
Uplinktrafficiscompletelyunpredictable.Again,inthecaseofaverybusylinkwithother
linksrelativelyidle,theHBSwillallocateextrauplinktimeslotstothebusylinkfromfreepool
only.Ifalloftheuplinktimeslotsareallocated,thenSBMwillnotoperateintheuplink
direction.
TheRADWINManagerprovidesfacilitiestoconfigureseparateuplinkanddownlinktimeslots
asshowninFigure 101andFigure 102above.Itfurthermonitorsperformance,providing
tabularandgraphicutilizationstatisticsdemonstratedbelow.
RADWIN5000HPMPUserManual

Release3.5.50

104

TrafficGenerationTools

TrafficGenerationTools
Forourexamplesinthischapter,weusedtheIperftrafficgeneratorwithitsGUIfrontend,
Jperf.Thesearefreeopensourcesoftwarepackagesfoundhere:
Iperf:http://sourceforge.net/projects/iperf/
Jperf:http://sourceforge.net/projects/jperf/
JperfincludestheIperfexecutable.
Theresultsbelowareindicativeratherthanaccurate.Accuratetrafficgenerationand
measurementrequirehardwaretools.Seeforexample,http://www.ixiacom.com/.

TrafficGenerationExamplesandmethod
EachcasedemonstratedbelowisbasedonasingleHBSwiththreefixedHSUs.Twoofthem
willbeidleandonewillbeheavilyloaded(thebusyHSU)todemonstratethefollowing
cases:
Table101:TrafficgenerationexamplesTimeslot(TS)Allocation
DownlinkTS
allocation

UplinkTS
allocation

Purpose

AllHSUs2TS

AllHSUs2TS

RequireddownlinkBWtakenfromunused
timeslots

BusyHSU2TS,
otherstakeall AllHSUs2TS
remainingTS

AllHSUs2TS

BusyHSU1TS,
otherstakeall
remainingTS

BusyHSUstarvedinuplinkdirection

AllHSUs2TS

BusyHSU1TS,
otherstakehalf
remainingTS

BusyHSUtakesunallocateduplinktime
slots

Example

RequireddownlinkBWtakenfrom
allocatedbutunusedtimeslots

WewilllookatExample1ingreatdetail,toensurethatyouunderstandeachitemappearing
intheSBMUtilizationwindow.Subsequentexampleswillbeexplainedmorebriefly,
concentratingonutilizationissuesratherthangraphicfeatures.
TrafficgenerationwasaccomplishedbyusingtwoparallelJperfsessions.Onesenttrafficat
100MbpsfromtheHBStotheHSU.Thesecondsenttrafficat50MbpsfromtheHSUtothe
HBS.Bothunitsweredrivenatmaximumcapacity.

RADWIN5000HPMPUserManual

Release3.5.50

105

Example1

Example1
Downlink
allocation

Uplink
allocation

Purpose

AllHSUs2TS

AllHSUs2TS

RequireddownlinkBWtakenfromunallocatedtimeslots

InFigure 103below,observethatthesectorisgrosslyunderallocated.Thissituationmight
beappropriateifalltheclientHSUweresupplyingInternetserviceonly.

Figure103:SectorstatusforExample1
TheRxandTxRatesfortheHBSinthemselvesdonotmeanverymuch.Butthechangesto
themwillbenoticeableinthenextthreeexamples,offeringacomparativebasisforvarious
timeslotallocations.

SectorUtilization
Sectorutilizationisdisplayedbyusingtherightmosttabonthemainwindowasseeninthe
nextscreencapture:

RADWIN5000HPMPUserManual

Release3.5.50

106

Example1

Figure104:SectorUtilizationPanefromthemainwindowforExample1
ThecurrentnumericalvaluesforeachmeasuredfieldfortheselectedHSUmaybeseenby
movingthehorizontalsliderjustbelowthebottomsegment.Thegraphsprovideatimeline.

RADWIN5000HPMPUserManual

Release3.5.50

107

Example1

Table 102explainsthepurposeofeachmeasurement.
Table102:TrafficstatisticsforeachHSU
Fieldname

Unit

Explanation

TrafficUL

Mbps

TrafficloadsenttotheHBS

TrafficDL

Mbps

TrafficloadreceivedfromtheHBS

SectorRelativeUL Percentage

PercentageofsectorULtimeslotsutilizedfor
transmissiontotheHBS.MaybeoverHSUsallocationif
thereareunallocatedULtimeslotsavailable.

SectorRelativeDL Percentage

PercentageofsectorDLtimeslotsutilizedforreception
fromtheHBS.MaybeoverHSUsallocationifthereare
availableULtimeslotsavailable,allocatedornot

HSUBased
RelativeUL

Percentage

PercentageofHSUULtimeslotsutilizedfortransmission
totheHBS.Maybeover100%ifthereareunallocated
ULtimeslotsavailable.

HSUBased
RelativeDL

Percentage

PercentageofHSUDLtimeslotsutilizedforreception
fromtheHBS.Maybeover100%ifthereareavailable
ULtimeslotsavailable,allocatedornot

Togetabetterideaofwhatishappening,wewillenlargeeachsectionofFigure 104inturn.
Thetoplefthandgraphshowssectorutilization:

Figure105:SectorUtilizationExample1
Figure 105showstheoverallsectorutilizationasseenbytheHBS.Atanypoint,youcan
mouseoveranyofthegraphstoseethecurrentvalueinalargermoreconvenientformat.

RADWIN5000HPMPUserManual

Release3.5.50

108

Example1

Thisisusefulifyouareusingalaptoporotherdevicewithasmallscreen.
ThevaluesinFigure 105areasexpected:TheHBSisusingalittleoverhalfitscapacityinthe
uplinkdirection.Theexcessisoverheadrequiredtomonitorthesector.Inthedownlink
direction,theexcessover50%isincidentalaswillbeseenfromthetoprightgraphshowing
sectorutilizationasatimeline:

Figure106:SectorUtilizationtimelineExample1
TheglitchesareduetoJperfandhostcomputerlimitations.
ThelowerpairofgraphsshowutilizationofaselectedHSUeithersectorrelativeorself
relative.UsetheselectorintheHSUutilizationtitlebartomakeachoice.

WefirstlookattheHSUbasedutilization.(Inourview,theSectorrelativemeasurementswill
makemoresenseifwefirstunderstandwhatishappeningattheHSUlevel.)
Figure 107showstheHSUrelativeutilizationfortheselectedHSU.Thegreenpercentage
barsareeasytounderstand.Theyarebothwellover100%sincethewholesectorisgrossly
underallocated.Bothvaluesareover1000%!Morespecifically,iftheHSUcouldonlyuseits
twoallocatedtimeslotsinbothdirections,itisfairlyeasytodemonstratethatitwouldnotbe
abletooperateatmaximumcapacity.Sinceitisabletoborrowtheunuseduplinkand
downlinktimeslots,itreachesmaximumthroughputandoperatesatovertentimesthe
assuredratedefinebytwotimeslotsinbothdirections.
RADWIN5000HPMPUserManual

Release3.5.50

109

Example1

TheblueuplinkanddownlinkbarsreflecttheamountoftrafficbeinghandledbythisHSU.
TheHSUitselfisa50Mbps(aggregate)unit,soitisoperatingatamaximumcapacityofabout
25Mbpsinbothdirections.Theblackfiguresaboveeachbarshowtheactualthroughputin
Mbpsandareupdatedaboutoncepersecond.

Figure107:HSUUtilizationHSURelativeExample1
HereisthetimelineforthesameHSU:

Figure108:HSUUtilizationHSURelativetimelineExample1
Next,weexaminethebehaviorofthisHSUrelativetothesector.

Figure109:HSUUtilizationSectorRelativeExample1
TheHSUutilizationacrossthesectorisnotverydifferentfromFigure 105,sincehaveone
busyHSUandtherestidle.
ThebusyHSUreceivesalltheresourcesitneeds,asreflectedbythebluethroughputbars
whicharealmostthesameasthoseinFigure 106.
Figure 1010showsthesectorrelativetimeline,whichisquitesteadyastobeexpected.
RADWIN5000HPMPUserManual

Release3.5.50

1010

Example2

Figure1010:HSUUtilizationSectorRelativetimelineExample1

Example2
Downlink
allocation

Uplink
allocation

Purpose

BusyHSU2TS,
otherstakeall AllHSUs2TS
remainingTS

RequireddownlinkBWtakenfromallocatedbutunused
timeslots

InFigure 1011below,observethatthesectorisfullyallocatedinthedownlinkdirection.

Figure1011:SectorstatusforExample2AllDLtimeslotsallocated

RADWIN5000HPMPUserManual

Release3.5.50

1011

Example3

SinceallunuseddownlinkslotsareavailabletothebusyHSU,theutilizationgraphsforthis
caseareverysimilartothoseofExample1andwewillnotrepeatthemall.Themain
differenceisinthesectorutilization:

Figure1012:SectorUtilizationExample2
ThedownlinkutilizationishigherthanforExample1,reflectingthefactthattheHBSmust
spendproportionallymoretimecheckingtheinactiveHSUs.
Similarly,theSectorrelativeHSUdownlinkutilizationishigherbythesameamount.

Example3
Downlink
allocation

Uplink
allocation

Purpose

AllHSUs2TS

BusyHSU1TS,otherstakeall
remainingTS

BusyHSUstarvedinuplinkdirection

Inthiscase,wearedeliberatelystarvingthebusyHSU,byallocatingitoneuplinktimeslot
anddividingtherestbetweentheinactiveHSUs.ThesituationisshowninFigure 1013.

RADWIN5000HPMPUserManual

Release3.5.50

1012

Example3

Figure1013:SectorstatusforExample3AllULtimeslotsallocated
TheeffectonsectorutilizationisquitedramaticasseeninFigure 1014below.

RADWIN5000HPMPUserManual

Release3.5.50

1013

Example3

Figure1014:SectorUtilizationPanefromthemainwindowforExample3
Uplinkutilizationis100%despitealmostnotrafficgettingthroughfromthebusyHSUtothe
HBSasseeninFigure 1015andtheenlargedlefthandbarchartinFigure 1016below:

Figure1015:HSUUtilizationSectorRelativetimelineExample3

RADWIN5000HPMPUserManual

Release3.5.50

1014

Example4

Figure1016:HSUUtilizationSectorRelativeExample3
Inallofthis,downlinkutilizationisunaffectedandremainsasforthefirstexample.
Theimportanceofleavingapoolofunallocateduplinktimeslots(ifpossible)isillustrated
inExample4,whichpreventsHSUstarvation.

Example4
Downlink
allocation

Uplink
allocation

AllHSUs2TS

BusyHSU1TS,otherstake
BusyHSUtakesunallocateduplinktimeslots
halfremainingTS

Purpose

Thisexample,asseeninFigure 1017leavesapoolofunallocatedULtimeslotstoavoidbusy
HSUstarvation.

RADWIN5000HPMPUserManual

Release3.5.50

1015

Example4

Figure1017:SectorstatusforExample4HalfULtimeslotsallocated

Figure1018:SectorUtilizationPanefromthemainwindowforExample4
RADWIN5000HPMPUserManual

Release3.5.50

1016

Example4

Figure1019:HSUUtilizationSectorRelativetimelineExample4
Thelefthandbargraphsforeachsectionareinstructive.Herefirst,isSectorUtilization:

Figure1020:SectorUtilizationExample4
ThedownlinkresultsreflectboththeactualtrafficandHBSmonitoringofalltheHSUs.The
uplinkfiguresreflectthesamething.Despitetherebeingmorethanadequatefreeuplink
timeslots,theHBSoverheadoftakingcareofinactiveHSUsisnoticeable.
HereisHSUselfrelativeutilization:

Figure1021:HSUUtilizationHSURelativeExample4
ThepercentageutilizationhereisveryhighsignificantlymoresothanExample1.Theactual
trafficthroughputstothebusyHSUareslightlylowerforthesameoverheadreasons.
SimilarconsiderationsarereflectedintheHSUssectorrelativeutilization:

RADWIN5000HPMPUserManual

Release3.5.50

1017

ExampleSummary

Figure1022:HSUUtilizationSectorRelativeExample4

ExampleSummary
Forreadabilityreasons,wewillusethelefthandbargraphsratherthanthetimelinesto
summarizethescenarios.Ineachcase,wehavechosenthebargraphstobeas
representativeaspossible.

RADWIN5000HPMPUserManual

Release3.5.50

1018

ExampleSummary

Ex.

AllHSUs2TS

AllHSUs2TS

BusyHSU1TS,othersallremainingTS

BusyHSU1TS,othershalfremainingTS

DL

AllHSUs2TS

BusyHSU2TS,others,remainingTS

AllHSUs2TS

AllHSUs2TS

HSUself

Sector

UL

HSUsector

Utilization

Table103:UnitizationSummaryforourfourexamples

RADWIN5000HPMPUserManual

Release3.5.50

1019

AboutHBSOverhead

AboutHBSOverhead
ThereisalwayssomeoverheadontheHBS.Recallthatonetimeslotineachoftheuplinkand
downlinkdirectionsisreservedbytheHBSforsectormanagement.
InourfourexampleswenotedthattheoccurrenceofHBSoverheadincreaseswhen
allocatingtimeslotseventoidleHSUs.
Aswesaw,thepercentagepointsectorloadincreasesasyouallocatefurtherdownlinktime
slots,ormaintainanyunusedbutallocateduplinktimeslots.
Itisstraightforwardtodemonstratethatoverheadisalsochannelbandwidthdependent.If
yourepeatthefourexamplesunder10and5MHzchannelbandwidth,theloadoverhead
percentageincreasesaschannelbandwidthdecreases.Conversely,ifyouareabletooperate
at40MHz,theoverheadpercentagedrops.
Toillustratetheeffectofdifferentchannelbandwidths,weshowinorder,Example3at10,20
and40MHz:

Figure1023:Example3:Halftheuplinktimeslotsreservedat10MHzCBW
Noticethatat10MHzchannelbandwidth,thesectorutilizationis100%inbothdirections!

RADWIN5000HPMPUserManual

Release3.5.50

1020

AboutHBSOverhead

Figure1024:Example3:Halftheuplinktimeslotsreservedat20MHzCBW
At20MHzchannelbandwidth,thesectorutilizationisaround80%intheuplinkdirectionand
abbot63%intheuplinkdirection.

RADWIN5000HPMPUserManual

Release3.5.50

1021

TCP/IPandotherSLAConsiderations

Figure1025:Example3:Halftheuplinktimeslotsreservedat40MHzCBW
At40MHzchannelbandwidth,thesectorutilizationisaround70%intheuplinkdirectionand
abbot26%intheuplinkdirection.Thepercentagesectorutilizationhasdroppeddramatically
forthesametrafficload.

TCP/IPandotherSLAConsiderations
TheforegoingexamplewereallbasedonUDPtraffic.IfthesectortraffichasaheavyTCP/IP
content(includingdependentprotocolssuchasHTTP/HTTPS)youmustallowsufficienttime
slotsparticularlyintheuplinkdirectiontoensurethethatTCP/IPACKmessagesare
transmittedwithoutdelay.Sometheoreticalcalculationsarepossible,butultimatelyyouwill
needtouseahardwaretrafficgeneratortoassistyourtimeslotallocation.Thisisparticularly
criticalifyouareoperatingasectorwithSLA.
ThesameholdstrueifyouareofferingabackhaulservicewithSLAregardlessofthetraffic
packetcomposition.

RADWIN5000HPMPUserManual

Release3.5.50

1022

Chapter11:

BringingUpaMobilitySector
ScopeofthisChapter
Mobilitysolutionsofferspowerful,easytodeploybasestationsthatguaranteehighcapacity
connectivitytoruggedizedmobileunitsmountedonvehicles,trainsandships.
RADWIN5000Mobilityenables:

Perimetersecuritytwowayvideotransmissionbetweenpatrolvehicles
OnboardvideosurveillanceandInternetaccessforpublictransportation
Oilrigtoshipvideoanddataconnectivity
Unmannedvehicleoperationremotecontrolofheavymachineryforminesandports

RADWIN5000isdesignedtoensurethatHMUsattaincontinuousservicewithinasectorand
seamlessservicewhencrossingintoanewsector.
Mobilityapplicationsaretypicallylargescaleprojects.Arailwayapplicationforexample,
requiresachainofoverlappedsectorsalonghundredsorthousandsofkilometersofrailway
track.
ThedetaileduseofRADWIN5000elementsinaMobilityapplicationisbeyondthescopeof
thismanual.ThepurposeofthischapteristodemonstratetheuseofRADWINManagerin
bringingupandmanagingaphysicallyinstalledMobilitysector.Inpractice,onesectorwould
bebuiltbyhand(aswewilldobelow).Thecompletesectorconfigurationcanbesavedand
uploadedtofurthersectors.
ForMobilityprojectmanagementquestions,pleaseconsultRADWINCustomerService.

Concepts
EachHMUisallocatedtooneoffourHBSlevelslabelledA,B,CandD.Theoperating
parametersforeachlevel(suchasVLAN,MIR,QoS,timeslots,fixedrate,Spatial
Multiplexing/Diversityantennamode)canbedifferentforeachlevelallowingforbroad
prioritizationofservicebetweendifferenttypesofmobileunits.ThisrequiresthateachHMU
beassignedaleveltojoinasector.TheactualjoiningprocessisquitedynamicsincetheHSU
willtypicallymovefromsectortosectorathighspeed.
RADWIN5000HPMPUserManual

Release3.5.50

111

WhatYouNeed

ChanginganyofVLAN,MIR,QoS,fixedrate,SpatialMultiplexing/Diversityantennamodefor
oneconfiguredHSUatagivenlevel,changesallotherHSUsatthatlevel.Ifyouaddanew
HSUtoasector(bydirectconnection)atagivenlevel,atsynctime,itwillacquiretheexisting
parametersforthatlevel.
AHMUmustbeabletosendandreceiveservicetrafficwhilemoving.Toavoidservice
glitcheswhileswitchingbetweensuccessiveHBSs,theHBShandovertimemustbevery
small.ForRADWIN5000HBSsitistypicallylessthan500ms,dependingonselectionof
Mobilitychannels.
AHMUdetectsthatitistimetoseekthenextHBSwhenitsratedropsbelowapredefined
minimumcapacitythresholdbasedonaminimumsupportedrate.TheHBSchosenwillbethe
firstfoundofferinganRSSlevelaboveaminimumthreshold(bydefault60dBm),whichyou
canconfigureforeachHMU.IfnoHBScanbefoundsatisfyingthelattercriterion,thenthe
HSUwillsyncwiththeHBSthathasthehighestRSSlevel(eventhoughitisbelowtheRSS
Threshold).
ItisuptotheMobilityProjectRFplannerstoensurethatHBSsarespacedwithcoverage
overlapsothatontheonehandtheHSURSSleveldoesnotfallsolowthatitloses
synchronizationbetweenHBSsandontheotherhand,successiveHBSsdonotinterferewith
oneanother.
InaMobilityproject,itisfairlytypicaltouseafixedchannelateachHBSandtohavethe
HSUsconfiguredtousethegroupofchannelsusedbytheHBSssoastominimizehandover
time.

WhatYouNeed
TheRADWIN5000Mobilityproductsaredifferentfromthefixed/nomadicproducts.They
havedifferentpartnumbers.EnsurethatyourHBSandHSUsasdeliveredaretheMobility
models.
Eachsectorcomeswithapreinstalledoperatingband.Youcanchangeitintheusualway.If
youdoensurethaneachoftheHSUsischanged.Alternatively(better),bringupthesectoras
isandchangethebandsectorwide.

GettingStarted
WewillcreateasectorwiththreeHMUs.Thereisnodifferenceinthelogonprocedureto
theHBS.Toavoidneedlessrepetitionandissuesnotreallyrelevanttothischapter,wewill
startoutwiththeHBSandtheHMUssettotherefactorydefaultsexceptfortheIPaddresses.
WewillmaintaintheIPaddressesusedinthepreviouschapters.Inpractice,theIPaddresses
ofsectorelementmaywellbeconfiguredusingDirectorLocalConnectionpriorto
reproductionofsectorparametersfromatemplatesector(suchaswearecreating)and
mostlikelybeforedeploymentinthefield.
FurtherwewillnotmakeanyuseoftheMapviewinthischapter.Onceagain,inpractice,a
MobilesystemwouldbemanagedfromaNOCusinganenterprisestandardNMS.
RADWIN5000HPMPUserManual

Release3.5.50

112

PreparingtheHBS

TheTableviewafterloggingontotheHBSlookslikethis:

Figure111:MobileHBSafterinitiallogon
YouactivatetheHBSintheusualway.Beawarethatuseoffixedversusautomaticchannel
selectionispartofyourRFplanning.
Wewillmaintainthenamingschemeusedinearlierchapters,butourHSUswillhavenames
likeHMU.01.01andsoon(insteadofHFUandHNUforfixesandnomadictypes).The
activationwizardpagesareidenticaltothoseusedforafixedsector.
ThefirstdifferencebetweenanewactivatedmobileandfixedsectoristhattheHSUsdonot
appearintheTableview.

PreparingtheHBS
OpentheConfigurationwindowandthentheMobilitytab:

RADWIN5000HPMPUserManual

Release3.5.50

113

PreparingtheHBS

Figure112:HBSMobilityConfiguration
ThemaximumdistanceisanominalcommondistanceassumedbytheHBSforallHMUsinits
sector.ItistakenasthemaximumdistanceanyHSUcanbefromaHBS.(Iteffectively
guaranteesanidenticalpropagationdelayforallHSUsinthesectortocompensateforrapid
HSUmovement.)Ifthedistanceissettoosmall,thereisariskofsynclossfordistantHSUs;if
itissettoolargeitwillreduceperformanceacrossthesector.ThechoiceispartofRF
planningforMobilityprojectsandisbeyondthescopeofthismanual.
WewillpreregisterthreeHSUslotstolevelsA,BandCandtimeslotstoeachlevelasshown:

RADWIN5000HPMPUserManual

Release3.5.50

114

PreparingtheHBS

Thetimeslotsasshownmean8downlinkand2uplinkperunitX3unitsatlevelAandsoon
upto63availabletimeslotsinbothdirections.ClickRegister,leavethemaximumdistanceas
isandclickOKtoleavetheconfigurationwindow.Hereistheresult:

WehaveplaceholdersforthemaximumallowableHMUsinthesector.

RADWIN5000HPMPUserManual

Release3.5.50

115

RegisteringHMUs

RegisteringHMUs
RegistrationofactualHMUsisaccomplishedbydirectconnection.Youassigneachonetoone
ofthefourlevels.Atthesametime,youmayconfigureotherparameterssuchasAir
Interface,IPaddress(thoughnotstrictlynecessary).Theprocessisslightlydifferentfor
VMUs.

ToassignaHMUtoalevelbydirectconnection:
1.LogontoaHMUintheusualway.Hereistheopeningwindow:

FortheVMU,thewindowisdifferent:

RADWIN5000HPMPUserManual

Release3.5.50

116

RegisteringHMUs

NoticetheGPSstatuspanelontheleftandtheWiFiactiveiconinthebottomstatus
bar.
2.OpentheConfigurationwindow.Updatethesystemparameters.

RADWIN5000HPMPUserManual

Release3.5.50

117

RegisteringHMUs

3.OpentheAirInterfacetab.

RADWIN5000HPMPUserManual

Release3.5.50

118

RegisteringHMUs

4.EntertheNetworkID(EBGXinourexample)andifnecessary,changetheChannel
Bandwidth.
5.OpentheTx&Antennatabandensurethattheantennatypeiscorrect.Youmay
changeanyotherantennaparametersaswell.WesetTxPowerforourexampleto5
dBm.
6.OpentheManagementtabandsettheHSUIPaddress.
7.FortheVMUs,opentheEthernettab.ThewindowisdifferentfromaregularHMU:

RADWIN5000HPMPUserManual

Release3.5.50

119

RegisteringHMUs

NoticetheequipmentPoEportisdisplayed.Further,youcanenable/disableWiFi
supporthere.Theeffectofcheckingoruncheckingthecheckboxisrespectively,to
poweruporpowerdowntheWiFiaccesspoint(notjusttostart/stopradiotransmit
/receive).
8.OpentheMobilitytab.Clicktherequiredlevel.WeleavethisHMUonA.Wewill
placeourothertwoHMUsinlevelB.

RADWIN5000HPMPUserManual

Release3.5.50

1110

RegisteringHMUs

9.SettheRSSthresholdparameter.
10.ChosetherequiredAvailableChannelsfromthelist.
11.Again,thefortheVMU,thewindowisslightlydifferent:

RADWIN5000HPMPUserManual

Release3.5.50

1111

RegisteringHMUs

TheVMUbatterymodeshutdowntimershouldbesethere.
12.ClickOKtoacceptyourchangesandclosethewindow.
13.RepeatabovestepsforeachHMU.
Forourexample,weassignoneHSUeachtolevelsA,BandC.Herethen,isthefinalresult:

RADWIN5000HPMPUserManual

Release3.5.50

1112

UpdateService

Figure113:ConfiguredMobilitysector
Fromthispoint,youmayusetheconfigurationandreportingfacilitiesintheusualway.

UpdateService
InaMobilitysector,serviceasdefinedbytimeslotallocationandthroughputsetting,is
carriedoutateachofthefourlevels,AD.Toshowhowitisdone,wewillupdatetheservice
atlevelAinthesectorofFigure 113.

ToupdatetheserviceatlevelA:
1.RightclickanyoneoftheHMUcardsinFigure 113.Thefollowingwindowisdis
played:

RADWIN5000HPMPUserManual

Release3.5.50

1113

UpdateService

EitherDiversityorAutoSelectionarerecommended.
2.Youmaychangetheratefromadaptivetofixedrate(theunitsareMbps):

Yourchoicewillbelargelyapplicationdependent.Forexample,forvideoapplica
tionsyouwoulduseafixedrate.ForInternetaccess,adaptiveisappropriate.
Forourexample,weleaveitatadaptive.
3.Forillustrativepurposes,changetheuplinktimeslotsperHMUfrom2to4.Youare
askedtoconfirmthechange:

4.ClickOKtoaccept.ThechangeisimmediatelyreflectedintheSectorstatuspanel:

RADWIN5000HPMPUserManual

Release3.5.50

1114

SavingtheHBSSettingsforReuseasaTemplate

Theallocatedpercentageofuplinktimeslotshasincreasedfrom29%to38%.

SavingtheHBSSettingsforReuseasa
Template
RefertoFigure 112ofwhichthefollowingisanexcerpt:

Followinganyfurtherfinetuning,openuptheHBSMobilitytab,andclickSave.Youare
offeredthestandardSaveFiledialog.SavetheHBSMobilitysettingsfile
(MobilitySettings.mob)toaconvenientlocation.

CreatingaSectorfromanHBSTemplate
Thesavedsettingsfilemaybeusedasatemplateforfurthersectors.

TocreateasectorfromaHBSMobilitysettingsfile:
1.StartingwithanewHBSandHSUs,logontotheHBS.
2.ActivatetheHBSintheusualway.
3.OpentheMobilitytabintheConfigurationwindow.IntheSave/UploadSettings
window,clickUpload.

RADWIN5000HPMPUserManual

Release3.5.50

1115

CreatingaSectorfromanHBSTemplate

Figure114:PreparingtouploadtheMobilityfile
4.InourcasewehaveoneHBS,soitissufficienttoentertheMobilityfileasshownand
thenclickStart.Afterafewmoments,theStatusfieldindicatesDone.

Theresultisasexpected:

YouwillofcourseneedtoseparatelyconfiguretheparticipatingHSUs.Ifweconnect
ourthreeconfiguredHMUs,wereverttoouroriginalsector.

RADWIN5000HPMPUserManual

Release3.5.50

1116

CreatingaSectorfromanHBSTemplateandanHBSList

CreatingaSectorfromanHBSTemplateand
anHBSList

TocreateasectorfromaHBSIPlistandaMobilitysettingsfile:
1.InthewindowofFigure 114,enteraHBSlistfile.Theformatofthefileislinesof
<IPaddress><ReadWritecommunity>

Forexample,
10.104.50.200netman
AlloftheHBSsneedtoactivatedandaccessible(viaaswitch)tothemanagingcom
puter.Theyneednotbeonthesamesubnet.
Alternatively,enterthemonebyoneusingthePlusbutton.

AnyunactivatedHBSswillbeshownasunavailable:

2.MakeanyfurtherchangestothedisplayedlistusingthePlus/Minusbuttons.
3.ClickStarttocommencetheprocess.
4.ThelistwindowwillindicatethesuccessorotherwiseoftheuploadforeachHBS.

WiFiConnectivityforaVehicularMobileUnit
GettingStarted
CompletingtheregularVMUregistrationisaprerequisitetoWiFiconnectivity.Thebase
stationbackhaulstheWiFitraffic.
Assupplied,theVMUisconfiguredassingleaccesspointwithSSIDInstall,andaccessible
overtheairfromalaptopequippedwithWiFihardware,runningunderWindows7orlater.
UnderWindows7,yourWiFisystemiconandWiFidisplayshouldlooksomethinglikethis:

RADWIN5000HPMPUserManual

Release3.5.50

1117

AccessingtheVMUwithaWebBrowser

Forinstallationpurposesonly,theVMUisaDHCP/DNSserverandyoudonotneedanyIP
address.YouhaveenoughconnectivitytopreconfiguretheVMUforservice;lateryouwillbe
abletoaccessitthroughitsLANcableorthroughaswitchtowhichitisconnected,toeffect
furtherconfigurationchanges.
WhileyouareconnectedtotheVMUforpreconfiguration,youwillprobablynothave
internetaccess,sincetheunitusesitsownbuiltingatewayandDNSresolver.

AccessingtheVMUwithaWebBrowser
Inwhatfollows,wewilluseMozillaFirefox,release16fordemonstrationpurposes.
Launchyourwebbrowser;ifyouhaveanonblankhomepage,youwillseesomethinglike
this:

Whateverthecase,cleartheURLfieldandtypeinonemorerandomcharacters:

RADWIN5000HPMPUserManual

Release3.5.50

1118

AbouttheOpenSourcelink

HittheEnterkey.Youareofferedalogonwindow.Theinitialusernameandpasswordare
respectively,adminandwireless.

Hereispartoftheopeningdisplay:

AbouttheOpenSourcelink
TheVMUWebsoftwaremakesuseofseveralOpenSourcepackages.Therelevantlicense
statementsarecontainedinatarball,whichmaybedownloaded,unpackedandviewed
fromtheOpenSourcelink.

RADWIN5000HPMPUserManual

Release3.5.50

1119

AboutPreConfiguration.

AboutPreConfiguration.
DuringtheuseoftheGUI,yourbrowsermaydisplaythismessage,followed
byapparentinactivity:

Note
UsethebrowserRefreshfunctiontoresumeactivity.
Inthissection,wewillvisitallofthebrowserfunctions,butwewillconfiguretheminimumto
getWiFioperational.

StartingPreConfiguration
ClicktheInterfacesbuttontoopentheInterfacesdisplay:

TheWANdisplayshowstheAPunitMACaddress,whichyoushouldstore.Ethernetmodeis
disconnectedthatis,theunitisnotavailableforservice.Later,wewillenableit.TheIP
addressisthedefaultIPaddressfortheunititself,formaintenancepurposes.Later,wewill

RADWIN5000HPMPUserManual

Release3.5.50

1120

ContinuingPreConfiguration

changeittomaketheunitaDHCPclientthroughaswitch.TheReceivedandTransmitted
figuresarecumulative.
TheVMUoperatesasoneormorevirtualAP(VAP)unitsuptoamaximumofeight.Forpre
configurationpurposes,thefirstavailableVAP,shownasWLAN1,issetupbydefaultwith
nameandSSIDInstall.

Caution

DonotchangetheWLAN1SSIDfromInstalltoanythingelseuntilyouare
certainthatyouaredonewithpreconfiguration.ChangingtheInstallSSID
movestheunitintoservicemodedisablingtheDHCP/DNSserver,
enablingEthernetserviceandbecomingaddressableonlyoverwirethrough
anIPaddress.

NoticefurtherfromtheWLAN1tablethateachVAPhasitsownMACaddress.Fromaservice
perspective,theVAPslooklikeseparatephysicalAPunits.
WewillconfigurethreeVAPsandcheckeachoneforconnectivitywitharemotelaptop.

Continuing Pre-Configuration
Preparing the Radio Parameters
TheSystempageitemsmaybeconfiguredlater.OpentheNetworkpage:

TheConnectionTypeisStaticIPaddressorDHCP.DHCPisthedefault.

ThedefaultIPaddressandsubnetmaskareprovidedforusewithastaticIPaddressorifthe
DHCPserverbecomesunavailable.Fordemonstrationpurposes,wewillleavethemasis.
Now,opentheWirelesspage.Themostimportantpartofpreconfigurationiscarriedout
here.

RADWIN5000HPMPUserManual

Release3.5.50

1121

PreparingtheRadioParameters

TheCountryCodeisanabsolutemust.Youcannotproceedwithoutit.

Note
RADWIN5000HPMPVMUcomplieswiththeIEEE802.11WiFistandardswhichvaryfrom
countrytocountry.Therearecountrydependentregulationsgoverningchannelallocation
andTxpowerconsiderationsforthe2.4GHzWiFiband.
Chooseyourlocation:

ClickSavetosaveyourchanges.Youwillnotbeabletoproceedwithoutsavingyourchanges.
Ifyoutouchanythingelseyouwillgetthefollowingprompt:

Thispromptwillreappearfromtimetotimeatmilestonesrequiringacommitbeforeyou
canproceed.
WithSavedone,youmaynowsetradiowideparameters:

RADWIN5000HPMPUserManual

Release3.5.50

1122

Security

Theradioisonbydefault.Youmayusethisbuttontoenableordisableitformaintenance.

Donotchangeitnow.Ifyoudo,youwilllockyourselfoutoftheunit.

Warning
TheModeb/g/nistheonlyoneavailable.WewillalsoaccepttheusualWiFidefaultchannel
6.Changeitlatertochannel1or11ifyouexperienceinterference.
Txpowermaybechosenfrom3dBmto16dBmforourlocation.Yourlocationmayoffera
differentmaximumTxpower.Forourpurposes,itmaystayat3dBm.

Security
Whileyouaredoingpreconfiguration,anyWiFiclientinrangecandetecttheunitwithSSID
Install.Hereisyourcurrentsituation:

RADWIN5000HPMPUserManual

Release3.5.50

1123

Security

CheckShowConnectedClients.Afterafewmomentsweseethis:

ThefirstMAC90:...isthedemonstrationworkstation.Theseconditemcommencing00:...is
unknownandpresumedasnooper.
ChangeNetworkAuthenticationfromDisabledasshown,toWPA2(PSK):

Changethepasswordandstoreitinasafeplace.Thepasswordlengthmustbebetweeneight
and32characters.

RADWIN5000HPMPUserManual

Release3.5.50

1124

PreparingAdditionalVAPs

ClickSavetopreserveyourchanges.Again,checkShowConnectedClients.Thistimethelist
isempty.Anyoneloggedonbeforemustlogonagainwiththepassword.

YoumayalsosetSSIDBroadcasttoOffwhenworkinginInstallmode.

Note

PreparingAdditionalVAPs
OpentheVirtualAP2page:

ClickCreate:

RADWIN5000HPMPUserManual

Release3.5.50

1125

PreparingAdditionalVAPs

First,noticethatthedefaultSSIDisdefault1andthecorrespondingbuttonisalsosolabeled.
Inlinewithourprogramofgettingservicestartedwithminimumconfiguration,wejust
changetheSSIDtosomethingmoremeaningful.
NextrepeattheprocedureforVirtualAP3.
Finally(thismustbethelaststep,aswearegoingtobedisconnected),changetheInstallSSID
aswell.
HereisthesituationpriortoourlastSave:

OnclickingSave,youareofferedaconfirmatorymessage:

ClickYestoacceptyourchanges.
RADWIN5000HPMPUserManual

Release3.5.50

1126

ConfirmingthePreConfiguration

Yourbrowsermaybecomeinactive,sincethereisnolongeranovertheairconnection.

ConfirmingthePreConfiguration
Toconfirmourworksofar,wemustconnecttheVMUunittoaDHCPserver,andthenaccess
eachoftheVAPsfromaremotelaptop.

CheckingtheGPS
ThefrontpaneloftheVMUhasaGPSstatusLED.TheGPSunitisfunctioningcorrectlywhen
theLEDissteadygreen.Otherconditionsareasfollows:
Table111:GPSStatusLEDs
LEDStatus

GPSStatus

Red

Disconnected

Amber

Connected,nosatellitesavailable(usuallywhenindoors)

Green,blinking

Connected,searching

Green

Connected,satellitefound

TheGPSdataaredisplayedontheVMUmainwindowstatusarea:

TheGPSdatamayalsobeviewedintheVMUWebInterface,whichinaddition,offersa
GoogleEarthmapcenteredonthecurrentlocation.SeeWEBInterfaceforVMUs.

RADWIN5000HPMPUserManual

Release3.5.50

1127

Chapter12:

MonitoringandDiagnostics
TheRADWINManagerapplicationenablesyoutomonitorthesector,aswellasperformbasic
diagnosticoperationssuchasthroughputtesting.
Thischaptercovers:

Retrievinglinkinformation
Throughputchecking
Recentevents
Performancemonitoring
ActiveAlarms
LinkBudgetCalculator
OnlineHelp
Obtainingsupport

RetrievingLinkInformation(GetDiagnostics)
TheGetDiagnosticsfeaturecollectsandwriteslinkandManagerinformationfromselected
sitesintoatextfile.Thefileinformationcanbeusedfordiagnosticsandshouldbesentto
RADWINCustomerServicetoexpediteassistance.
Thefollowingtablelistslinkandsysteminformationthatcanbemonitored.
Table121:GetDiagnosticsDataandDescription
Data

Description

SystemData

Generalinformationaboutthesystem

EventsLog

Listofsystemeventsincludingthosefromothersitesifthissite
isdefinedasthetrapdestination
Last256eventsfromallsites

SectorInformation InformationabouttheHBSandHSUsettings
SiteConfiguration

Dataaboutthesiteparameters

RADWIN5000HPMPUserManual

Release3.5.50

121

RetrievingLinkInformation(GetDiagnostics)

Table121:GetDiagnosticsDataandDescription(Continued)
Data

Description

Monitor

Detailedeventdatarecord

RestrictionTable

ThisistheConnectionTablefromFigure 817

ActiveAlarms

ActiveAlarmsareraisedforanyeventaffectingavailabilityorquality

Performance

Networkperformancedataoverdefinedtimeperiodsevery15

SpectrumAnalysis

ForHBS,selectedHSUsandgeneralinterfencestatisticsforthesector

Togetdiagnostics:
1.ClicktheGetDiagnosticsbutton:

Figure121:GetDiagnosticsDialogBoxHBS

RADWIN5000HPMPUserManual

Release3.5.50

122

RetrievingLinkInformation(GetDiagnostics)

Figure122:GetDiagnosticsDialogBoxHSU
2.Selectordeselectthedataoptions.IfthefileistobesenttoRADWINCustomer
Serviceleavealloptionschecked.
3.HBSonly:ChooseHSUstobeincluded.
4.ClickFilePathtospecifythefilenameandolderinwhichyouwanttosavethefile
andthenclickRuntosavetheinformation.
Oncompletion,thestatusofthecheckeditemsisconfirmed:

RADWIN5000HPMPUserManual

Release3.5.50

123

LinkCompatibility

ThecontentoftheDiagnosticsreportisanaggregateofallthemorespecificreports
discussedbelow.ItisprimarilyintendedforusebyRADWINCustomerService.

Note

TheSpectrumAnalysisoutputisavailabledirectlyfromtheSpectrumView
utilityasaCSVfile(seeChapter24).TheformatintheDiagnosticsreportis
intendedforusebyRADWINCustomerService.
TheSpectrumAnalysissectionoftheDiagnosticsreportisbasedonthelast
availablespectrumanalysis(ifany).Ifyouaresubmittingasupportrequest
involvinginterferenceissues,orifyouarespecificallyaskedbyCustomer
ServicetosubmitaDiagnosticsreportcontainingarecentspectrum
analysis,youshouldcarryouttheanalysisinaccordancewiththe
instructionsinChapter24priortousingtheGetDiagnosticsfacility.

LinkCompatibility
CompatibilitybetweentheHBSandanHSUisprimarilydeterminedbythesoftwarelevelof
eachelement.Advisorymessagesaretypicallydisplayedasfollows:

RADWIN5000HPMPUserManual

Release3.5.50

124

SoftwareUpgradeavailable

Figure123:TypicalincompatiblymessagesforHSUsonHBSdisplay
OntheHBSwindow,thesemessagescanonlybeseeninHSUlistmode,andintheHBSActive
Alarmslog.

Figure124:ThisHSUrequiresasoftwareupgrade
OntheHSUwindow,thesemessagesappearasshowninFigure 124.
Themessagesareasfollows:

SoftwareUpgradeavailable
Thisisanadvisorymessage.Iftheupgradeisnotcarriedout,thencorrectionsintheupgrade
willnotbeavailable.ThismessagemayappearforanactiveHBSoranyHSUinthesector,
registeredornot.

RADWIN5000HPMPUserManual

Release3.5.50

125

SoftwareUpgraderecommended

SoftwareUpgraderecommended
Thisisalsoanadvisorymessage.IttypicallyoccurswithanewHBSornewHSUsaddedtoa
sector.
Iftheupgradeisnotcarriedout,thentheHBSorHSU(s)willoperatewithlimitedor
degradedfunctionality.ThismessagemayappearforanactiveHBSoranyHSUinthesector,
registeredornot.

SoftwareUpgraderequired
ThismessagewillbedisplayedifaproductbandIDmismatchisdetected.
ThusforaHBS,itcannotoccurunlessoneormoreHSUsareregistered.AffectedHSUswill
alwaysshowitasdepictedaboveinFigure 124above.
ForsuchHSUs,trafficisdisabledandtheonlyservicesavailableareChangeBandand
SoftwareUpgrade.

ThroughputChecking
Inthismode,RADWIN5000HPMPestimatesEthernetthroughputbyfillingframesoverthe
airtomaximumfor30seconds.Thismodeshouldnotinfluenceservice.Thetestmaybe
carriedoutfortheHBSoranHSU.

TouseThroughputChecking:
1.HBS:ChoseEstimatedThroughputasshown:

HSUfromHBS:ChoseEstimatedThroughputasshown:

RADWIN5000HPMPUserManual

Release3.5.50

126

ThroughputChecking

HSUdirectorovertheair:Unavailable.
2.Ineithercase,youareaskedtoenterthetestingperiod:

3.EntertherequiredtimeandclickOKtocontinue.TheEthernetservicesareachanges
appearanceandtheestimatedthroughputisdisplayed:

Attheendof30seconds,thedisplayrevertstonormal.

RADWIN5000HPMPUserManual

Release3.5.50

127

RecentEvents

RecentEvents
TheRecentEventslogrecordssystemfailures,lossofsynchronization,lossofsignal,
compatibilityproblemsandotherfaultconditionsandevents.

Note

Theforegoingeventtypesincludeeventsfromalllinksforwhichthis
managingcomputerhasbeendefinedasthetrapsaddress.Onlyevents
fromRADWINequipmentwillbeshown.

Alarms(traps)aredisplayedintheEventsLoginthelowerpanelofthemainwindow.The
EventsLogmaybesavedasatextfile.
TheEventsLogincludesthefollowingfields:

Sequentialnumber(ID)
Dateandtimestamp
Message
Trapsource
IPaddressoftheODUthatinitiatedalarm.

YoumayfiltertheeventsshownbychoosingAllorInternal.

AfullreportmaybeseembyclickingRecentEvents:

RADWIN5000HPMPUserManual

Release3.5.50

128

PerformanceMonitoring

Figure125:RecentEvents:Lefttoright:HBS,HSUfromHBS,HSUdirect
Ineachcasethereporthasthesameformat:

Hereisamorereadableenlargementofthetablearea:

Theleftbuttonmaybeusedtosavethereporttoafile.

PerformanceMonitoring
RADWIN5000HPMPPerformanceMonitoringconstantlymonitorstrafficovertheradiolink
andcollectsstatisticsdatafortheairinterfaceandEthernetports.Itdoessocontinuously,
evenwhentheRADWINManagerisnotconnected.

RADWIN5000HPMPUserManual

Release3.5.50

129

HBS

Figure126:PerformanceMonitoring:L.toR.HBS,HSUfromHBS,HSU
Theonscreenandgeneratedreportshavethesamegeneralformats,butthereare
differencesinwhatisreported.

HBS
TheHBSPerformanceMonitoringwindowoffersthefollowingbuttonmenu:

Choosethedataperiodrequiredwiththe15Minutesbutton.

Currentgivesyouthelatestentry.
15Minutesprovidesdatainascrolldownlistin15minuteintervals
Daily(24hours)showsresultsforthelast30daysatmidnight.

TheThresholdbuttonenablesyoutosettheuppertrafficthresholdforreporting.Traffic
conditionsabovethethresholdindicatecongestionandprobablylostframes.

RADWIN5000HPMPUserManual

Release3.5.50

1210

HBS

Figure127:Settingtheuppertrafficthreshold
Togetdatafordisplay,clickGetData.Theprocessmaytakeafewseconds.
HereisanextractPerformanceMonitoringreportbasedon15minutesrecording:

Figure128:HBSPerformanceMonitoringreportValiddata
Themeaningofthecolumnheadingsisshowninthefollowingtable:
Table122:HBSPerformanceMonitoringFields
Abbreviation
Meaning

Description

Integrity

Validdataflag

Greentickforcurrentandvalid;Redcrossfor
invalidateddata(Seeexamplebelow).Notethatthe
PerformanceMonitoringdataisnotvalidifnotallthe
valueswerestored(e.g.,duetoclockchangeswithin
theintervalorpowerupreset)

Date&Time

Timestamp

Dataarerecordedevery15minutes;thelast30days
ofrecordingsaremaintained.Rolloverisatmidnight.

UAS

Unavailable
Seconds

Secondsinwhichtheinterfacewasoutofservice.

ES

Erroredseconds

Thenumberofsecondsinwhichtherewasatleast
oneerrorblock.

SES

SevereErrored
Seconds

Thenumberofsecondsinwhichtheservicequality
waslowasdeterminedbytheBBERthreshold.

ColumnHeading

RADWIN5000HPMPUserManual

Release3.5.50

1211

HSU

Table122:HBSPerformanceMonitoringFields(Continued)
ColumnHeading

Abbreviation
Meaning

Description

BBE

Background
BlockError

Thenumberoferroredblocksinaninterval.

RxMBytes

Received
Mbytes

ThenumberofMegabytesreceivedatthespecified
portwithintheinterval

TxMBytes

Transmitted
Mbytes

ThenumberofMegabytestransmittedatthe
specifiedportwithintheinterval.

AboveTraffic
Thresh

Thresholdsetin Secondscountwhenactualtrafficexceededthe
Figure 127
threshold

ActiveSeconds

ThenumberofsecondsthattheconfiguredEthernet
serviceisactive

Databecomesinvalidatedfollowingareset.Intheexamplebelow,theHBSwasresetshortly
after11:00.Alldatapriortothattimebecomesinvalidated.Theonlyvaliditemisthefirst
recordingafterresync.

Figure129:HBSPerformanceMonitoringreportShowinginvaliddata
UsetheSavebuttontostorethecurrentdatatofileandtheClearbuttontodeletecurrently
storedperformancedata.
HSU

ThePerformanceMonitoringwindowfortheHSUisslightlydifferentdependingonwhether
youaccessitfromtheHBSordirectly:

FromtheHBS

RADWIN5000HPMPUserManual

Release3.5.50

1212

HSU

Youmaychosebetweenanuplinkordownlinkreport.Theremainingbuttonshavethesame
functionalityastheydofortheHBS.(Thereisnosignificanceinmonitoringperiodbutton
label,Daily.TheoptionsareasfortheHBS.)

DirectorOvertheAir

Here,onlyadownlinkreportisavailable.Otherwisethebuttonshavethesamefunctionality
astheydofortheHBS.
Hereisanextractfroma15minutereport.Wehavebrokenitintothreepiecessothatitis
legible:

Figure1210:HSUPerformanceMonitoringValidandinvaliddata(1of3)

Figure1211:HSUPerformanceMonitoringValidandinvaliddata(2of3)

RADWIN5000HPMPUserManual

Release3.5.50

1213

HSU

Figure1212:HSUPerformanceMonitoringValidandinvaliddata(3of3)
TheHSUreportcontainsmanymorefieldsthantheHBS.Hereistheirmeaning::
Table123:HSUPerformanceMonitoringFields
Abbreviation
Meaning

Description

Integrity

Validdataflag

Greentickforcurrentandvalid;Redcrossfor
invalidateddata(Seeexamplebelow).Notethatthe
PerformanceMonitoringdataisnotvalidifnotallthe
valueswerestored(e.g.,duetoclockchangeswithin
theintervalorpowerupreset)

Date&Time

Timestamp

Dataarerecordedevery15minutes;thelast30daysof
recordingsaremaintained.Rolloverisatmidnight

UAS

Unavailable
Seconds

Secondsinwhichtheinterfacewasoutofservice

ES

Errored
seconds

Thenumberofsecondsinwhichtherewasatleastone
errorblock.

SES

SevereErrored Thenumberofsecondsinwhichtheservicequality
waslowasdeterminedbytheBBERthreshold
Seconds

BBE

Background
BlockError

ColumnHeading

Thenumberoferroredblocksinaninterval

MinRSL(dBm)

Theminimumofthereceivesignallevel(measuredin
dBm)

MaxRSL(dBm)

Themaximumofthereceivesignallevel(measuredin
dBm)

RSLThresh1(
88dBm)

ThenumberofsecondsinwhichtheReceiveSignal
Level(RSL)wasbelowthespecifiedthreshold.

RADWIN5000HPMPUserManual

Release3.5.50

1214

MoreontheThresholds

Table123:HSUPerformanceMonitoringFields(Continued)
ColumnHeading

Abbreviation
Meaning

Description

RSLThresh2(
88dBm)

ThenumberofsecondsinwhichtheRSLwasbelow
thespecifiedthreshold.

MinTSL(dBm)

Theminimumofthetransmitsignallevel(measuredin
dBm)

MaxTSL(dBm)

Themaximumofthetransmitsignallevel(measuredin
dBm)

TSLThresh(25
dBm)

ThenumberofsecondsinwhichtheTransmitSignal
Level(TSL)wasabovethespecifiedthreshold

BBERThresh
(1.0%)

ThenumberofsecondsinwhichtheBackgroundBlock
ErrorRatio(BBER)exceededthespecifiedthreshold

RxMBytes

Received
Mbytes

ThenumberofMegabytesreceivedatthespecified
portwithintheinterval

TxMBytes

Transmitted
Mbytes

ThenumberofMegabytestransmittedatthespecified
portwithintheinterval.

BelowCapacity
Thresh

(0.0Mbps)

Secondscountwhenthroughputfellbelowthe
thresholdsetinFigure 127

AboveTraffic
Thresh

Thresholdset
inFigure 127

Secondscountwhenactualtrafficexceededthe
threshold

AsfortheHBS,usetheSavebuttontostorethecurrentdatatofileandtheClearbuttonto
deletecurrentlystoredperformancedata.

MoreontheThresholds
RSLThresholds
TwoRSLThresholdscanbedefined.Theyareusedasanindicatorofproblemsintheradio
channel.YoucanchecktheRSSfromtheLinkBudgetCalculatorresultsduringinstallation.
Valuesof5dBand8dBfromthecurrentRSSaretypical.
TSLThreshold
Acounterismaintained,ofthenumberofsecondintervalsduringwhichTxpowerexceeds
thisthreshold.
BBERThreshold
TheBackgroundBlockErrorRatioismeasuredasapercentage.Thethresholdcanbesetfrom
0.1%upto50%.
An8%thresholdisrecommended.Iftherearenoproblemsduringtheinterval,thenforthat
threshold,therecommendedBBERvalueshouldbe0.Sincethesystemprovidesalossless

RADWIN5000HPMPUserManual

Release3.5.50

1215

RADWINManagerTraps

Ethernetservice,thereisthroughputdegradationincaseofinterference.Thedegradationis
proportionaltotheBBER.
EthernetThresholdsCapacity
ThisisusedasabasisforcheckingadherencetoaServiceLevelAgreement.Itisthenumber
ofsecondscountthatthelinkcapacityfallsbellowthethreshold.
EthernetThresholdsTraffic
Thenumberofsecondscountthatreceivedtrafficexceededthisthreshold.Itcanbeusedto
measuretrafficpeaks.

RADWINManagerTraps
TheRADWINManagerapplicationissuestrapstoindicatevariousevents,displayedinthe
EventsLog.
Table124:RADWINManagerTrapMessages
TrapMessage

Severity

Remarks

Cannotbindtotrapserviceport.Port Warning
162alreadyinusebyProcessName
(pid:ProcessId)

RADWINManagerwillnotcatchany
trapsfromtheODU,someother
applicationhasgrabbedthisport.

Deviceunreachable!

Error

CheckconnectivitytoODU

Connectedto<site_name>

Information

<site_name>Sitewillbereset.

Information

RestoreFactoryDefaultSettingsin
processonSite<site_name>

Information

FactorySettings:Theprocesswasnot Warning
finishedduetoconnectionissues.

Factorysettingfaileddueto
connectivityproblemtoODU

Reset:Theprocesswasnotfinished
duetoconnectionissues.

Factorysettingfaileddueto
connectivityproblemtotargetODU
willnotbereset

Warning

CannotWritetoMonitorfile.Thereis Warning
notenoughspaceonthedisk.

Freesomespaceondiskonthe
managingcomputerandretry

WindowsError:<error_ID>.Cannot
WritetoMonitorfile.

Warning

OperatingSystemerroronthe
managingcomputer

IdenticalIPaddressesat
<local_site_name>and
<remote_site_name>

Warning

SetupadifferentIPtoeachsite

TheProductisnotidentifiedatthe
<local_site_name>site.

Warning

RADWINManagerisincompatible
withtheODUsoftwareversion

RADWIN5000HPMPUserManual

Release3.5.50

1216

ActiveAlarms

Table124:RADWINManagerTrapMessages(Continued)
TrapMessage

Severity

TheProductisnotidentifiedatthe
<remote_site_name>site.

Warning

TheProductisnotidentifiedatboth
sites.

Warning

ProductNotIdentified!

Warning

TheManageridentifiedanewerODU Warning
releaseatthe<remote_site_name>
site.

Remarks

ODUreleaseisnewerthanRADWIN
Managerrelease.
Wizardsarenotavailable.RADWIN
Managerwillbeusedjustfor
monitoring.UpgradetheRADWIN
Manager.(Youwillgetthismessage
asapopup)

TheManageridentifiedanewerODU Warning
releaseatthe<local_site_name>
site.
NewerVersionidentifiedatthe
<local_site_name>site.

Warning

NewerVersionidentifiedatthe
<remote_site_name>site.

Warning

NewerVersionIdentified!

Warning

ODUreleaseisnewerthanRADWIN
Managerrelease.
Wizardsarenotavailable.RADWIN
Managerwillbeusedjustfor
monitoring.UpgradetheRADWIN
Manager.

ActiveAlarms
ActiveAlarmsareraisedforanyeventaffectingavailabilityorqualityofservice.
TheActiveAlarmsbutton,

isavailablefortheHBSandtheHSUs.Hereisanexample:

Hereisthetablepartinmoredetail:

RADWIN5000HPMPUserManual

Release3.5.50

1217

OtherDiagnosticAids

CurrentActiveAlarmsmaybesavedtoafile.Thelistdisplayedwillnotbeupdatedunlessyou
clickRefresh.

OtherDiagnosticAids
LinkBudgetCalculator
TheLinkBudgetCalculatorispartoftheRADWINManagersoftwareandisfoundintheHelp
menu.Thisusefulutilityenablesyoutocalculatetheexpectedperformanceofthewireless
linkandthepossibleconfigurationsforaspecificlinkrangeincludingantennasize,cableloss
andclimateconditions.Forfulldetails,seeChapter23.

ToruntheLinkBudgetCalculatorfromtheWindowsStartMenu:
GotoStart|Programs|RADWINManager|LinkBudgetCalculator

OnlineHelp
OnlinehelpcanbeaccessedfromtheHelpmenuonthemainwindowoftheRADWIN
Manager.UsingmostcommonWebbrowsers,itmayalsoberungoingto
Start|Programs|RADWINManager|UserManualRADWIN5000

CustomerService
CustomersupportforthisproductcanbeobtainedfromthelocalVAR,Integratoror
distributorfromwhomitwaspurchased.
Forfurtherinformation,pleasecontacttheRADWINdistributornearesttoyouoroneof
RADWIN'sofficesworldwide.

RADWIN5000HPMPUserManual

Release3.5.50

1218

Part4:SiteSynchronization

Release3.5.50

Chapter13:

HubSiteSynchronization
WhatisHubSiteSynchronization(HSS)
Whenseveralradiosarecollocatedatacommonhubsite,interferencemayoccurfromone
unittoanother.RADWINODUssupportthecollocationofmorethantwounitsatacentral
site.LikeanyotherRFdeployment,thewirelessoperationishighlydependentonfactors
suchasavailablefrequencies,thephysicalspacingbetweenradios,otherthirdparty
interferingradios,andwhetherotherRADWINradiosareinstalled.

Note

HSSdoesnoteliminatetheneedforcarefulRFplanningtoensurethe
designwillworkasplanned.SeeSiteSurveyforinformationoninstallation
sitesurvey.

RADWINHSS
TheRADWINHSSmethodusescarriespulsessenttoeachODU,whichsynchronizetheir
transmissionwitheachother.Thepulsesynchronizationensuresthattransmissionoccursat
thesametimeforallcollocatedunits.Thisalsoresultsinallofthehubsiteunitsreceiving
dataatthesametime,eliminatingthepossibilityofinterferencethatcouldresultifsome
unitstransmitwhileotherunitsatthesamelocationreceive.
Figure 131illustratesinterferencecausedbynonsynchronizedcollocatedunits.

RADWIN5000HPMPUserManual

Release3.5.50

131

RADWINHSS

Figure131:Interferencecausedbycollocatedunits
AddingHSSremovesinterferenceasshowninthenexttwofigures:

Figure132:CollocatedunitsusingHubSiteSynchronization(1)

Figure133:CollocatedunitsusingHubSiteSynchronization(2)
TheunitsareconnectedtoeachotherwithHSScablesandHSSDistributionUnits.
OneoftheradiosinthesiteisdefinedasHSSMasterandgeneratessynchronizationpulses.
TheothercollocatedradiosinthesitetheHSSClients,areconnectedtotheHSSMasterand
synchronizetheirtransmissiontothepulses.AnHSSClientcanbeconfiguredtoworkinone
oftwomodes:
RADWIN5000HPMPUserManual

Release3.5.50

132

RADWINHSS

HSSClientContinueTransmission(HSCCT):Iftheunitlosessynchronizationwiththe
HSSMaster,thelinkremainsactive.However,withoutsynchronizationpulses,itispos
siblethatthisunitwillcauseinterference.
HSSClientDisableTransmission(HSCDT):Iftheunitlosessynchronizationwiththe
HSSMaster,thelinkisdroppeduntilthesynchronizationpulsesresume.Thissetting
preventstheunitfromcausinginterference.

TheremoteODUsthatarenotlocatedatthehubsite,arecalledIndependentUnits(INU).
RADWINofferstwotypesofHSS:

SerialHSS
TheRADWINSerialHubSiteSynchronization(SHSS)methodusesacableconnected
fromthemasterODUtoallcollocatedODUs;thiscablecarriespulsessenttoeach
ODU,whichsynchronizetheirtransmissionwitheachother.SHSSiscoveredinChap
ter14.
EthernetHSS
TheEthernetHSS(HSSoE)methodrequiresLayer2Ethernetconnectivitybetween
collocatedODUs.Ithastworequirements:
CollocatedODUsprovidingEthernetservicesonly,shouldbeconnectedtoanIDUH
insteadofregularPoEdevices.Othersimpleswitchesmayworkwithdegradedper
formance.Theyarenotrecommendedandproblemsarisingfromtheirusewillnot
beeligibleforanykindofsupport.
CollocatedODUsprovidingE1/T1servicesshoulduseanIDUCorIDUEandthenbe
connectedtoanIDUHfunctioningasaswitch.OneoftheLANportsontheIDUCor
IDUEisconnectedtoanyofthesixIDUHPoEportsorthetwoLANports.(Thisis
possiblebecausetheIDUCorIDUELANcableonlyusesfourpinsfordata;the
powerpinsarenotusedsothereisnoriskofdamagetothem.)Inthisway,upto
eightsuchODUsmaybecollocated.

YoumayonlyuseoneIDUH.Thatis,theymaynotbecascaded.

Note

Caution

IfyouareusinganIDUC0(GbE)itmustbeconnectedtotheIDUHLANport
only.ConnectingittothePoEportswilldamagetheunitandinanyevent,it
willnotwork.

RADWIN5000HPMPUserManual

Release3.5.50

133

HSSConcepts:RadioFramePattern(RFP)

HSSConcepts:RadioFramePattern(RFP)
ARadioFramePattern(RFP)isthecycledurationoftransmitandreceiveoftheairframe.

WithoutHSS
WhenselectingTDMorEthernetservices,thesystemautomaticallyandtransparently
choosestheoptimalRFP.WhenTDMandEthernetservicesareconfigured,theRFPis
optimizedforTDM.

RFPandHSS
WhenHSSisused,theRFPforthecollocatedradiosmustbeselectedmanually.
RADWIN2000usestheTimeDivisionDuplex(TDD)mechanism.
UnderHSS,TDDenablessynchronizationoftransmissionforthecollocatedunitsasshownin
Figure 134:

Figure134:RadioFramePattern
TwoRFPtypes(labelledBandE)areavailable.UnderHSStheRFPmustbeconfiguredbythe
userdependingonthetypeoftheradioproducts,servicesandchannelbandwidthin
accordancewithTable 132.
ThetabledescribetheefficiencyoftheairinterfaceaccordingtotheRFPtype,servicesand
channelbandwidth.ThetablesmayalsobeviewedintheRADWINManagerandintheLink
BudgetCalculator.Theefficiencyoftheairinterfacewillvaryaccordingtotheproductused.
Table131:RadioFramePatternTableRADWIN5000HBS
RFP 5/10/20/40MHz
TDM
Ethernet
E
N/A
Bestfit
Table132:RadioFramePatternTableRADWIN2000
RFP 40MHz
20MHz
10MHz
5MHz
TDM
Ethernet TDM
Ethernet TDM
Ethernet TDM
Ethernet
B
Available Available Available Available Available Available Bestfit Bestfit
E
Bestfit Bestfit Bestfit Bestfit Bestfit Bestfit Available Available

RADWIN5000HPMPUserManual

Release3.5.50

134

RFP:GeneralRadioFramePattern

Table133:LegendforRadioFramePatternTables
Item

Description

Bestfit

OptimalRFPchoiceforTDMandEthernetservices

Available

AvailableRFPforTDMandEthernetservices,butnotoptima

N/A

Serviceunavailable

SelecttheRFPthatgivesyoutheBestFitorAvailableforrequiredsystemservicesandselect
thechannelbandwidthaccordingly.

TheRFPmustbethesameforeachlinkwithinthecollocatedsystem.

Note

RFP:GeneralRadioFramePattern
WhensettingtheRPF,thefollowingconsiderationsshouldbeborneinmind:

WhensynchronizingRADWIN5000HBSunitsyoumustuseRFPE
WhensynchronizingRADWIN5000HBSwithRADWIN2000orWinLink1000unitsyou
mustuseRFPE
RFPinfluencescapacityandlatency.
UsingtheLinkBudgetCalculator,youcanseetheeffectoftheRFPontheEthernet
throughput.

WhichTypeofHSStoUse
YoumayusebothformsofHSSwiththeHBS.Therearehoweversomelimitations:

IfyoucollocateanHBStobothaunitsupportingSHSSandHSSoE,theHBSmustalways
beHSM
IfyoucollocatewithaGSU,youcanonlyuseHSSoEandtheGSUmastbeHSM.

RADWIN5000HPMPUserManual

Release3.5.50

135

Chapter14:

SerialHubSiteSynchronization
RADWINSerialHSS
TheRADWINSerialHubSiteSynchronization(SHSS)methodusesaCAT5ecableconnected
fromthemasterODUtoallcollocatedODUs;thiscablecarriespulsessenttoeachODU,
whichsynchronizetheirtransmissionwitheachother.
SincetheSHSSunitisstillshownintheRADWINCatalogasanHSSunit,intheremainderof
thischapterwewillcontinuewiththisconventionontheclearunderstandingthatweare
dealingonlywithSHSS.

HardwareInstallation
ConnectinganHSSUnit
AsingleHSSunitsupportsuptotencollocatedODUs.Inadditiontoeachunitbeing
connectedtoitsIDUorPoEdevice,thecollocatedunithasanadditionalcablethatis
connectedtotheHSSUnit.TheHSSUnitisacompact,weatherproof(IP67)connectorbox
thatisinstalledonthesamemastastheODUs.Allcollocatedunitsconnecttothisboxusing
CAT5ecable.Cablesinpreparedlengthsareavailableforpurchase.
TheHSSunitissuppliedwithtenprotectivecovers;anyportnotinusemustbeclosedwitha
protectivecover.

RADWIN5000HPMPUserManual

Release3.5.50

141

ConnectinganHSSUnit

Figure141:HSSInterconnectionUnit

Note

ForasingleHSSunit,ensurethatthecollocatedunitsareconnectedin
sequencefromSYNC1.IfanODUisremovedfromthehubsite,then
allremainingODUsmustbereconnectedtomaintaintheconnectivity.
Youmaycascade(daisychain)twoormoreHSSUnitswithanHSS
cable.Themethodisdescribedindetailbelow.

ToconnectanODUtoanHSSunit:
1.UnscrewtheprotectivecoverfromtheportmarkedSYNC1.
2.ConnecttheRJ45connectorfromoneendofthepreparedCAT5ecabletoSYNC1.
3.ConnecttheotherendoftheCAT5ecabletotheODUconnectorlabeledSYNC.
4.TightentheprotectivesealthatisonthepreparedcableovertheRJ45connector.
5.RepeatforallODUsthataretobecollocatedatthehubsite.ThenextODUtobe
connectedisinsertedinSYNC1,SYNC2,followedbySYNC3andsoon.

RADWIN5000HPMPUserManual

Release3.5.50

142

UsingaSingleHSSUnit

UsingaSingleHSSUnit

Figure142:HSSWiringschematic
Thewiring,asshowninFigure 142isselfexplanatory.TheSyncsignalpathislessself
evident.IfwesetODU1(onSYNC1)toHSSMaster,thentheSyncsignalpathisasshownin
Figure 143.ThesignaltravelsfromODU1toSYNC1,fromSYNC1toSYNC2,fromSYNC2to
ODU2andbackagain.ThebackandforthpathsrepeatforthesecondtofourthODU,from
lefttoright.ThesignalexitstheHSSunitatSYNC5andterminatesinODU5.
ThechoiceoftheODUonSYNC1asHSSmasterisnotmandatory,butisgoodpractice.Iffor
exampleweweretouseODU3asHSSmaster,theSyncsignalpathwouldbeODU3toSYNC
3,thenleftandrighttoSYNC2andSYNC4.ItwouldthenpropagatetoODUs2and4,
terminatingatbothODUs1and5.

Figure143:HSSsyncsignalpathwithODU1asHSSMaster

UsingMorethanOneHSSUnit
Inalargecollocationsite,severalHSSunitsmaybecascaded(daisychained)subjecttothe
followingconditions:

RADWIN5000HPMPUserManual

Release3.5.50

143

UsingMorethanOneHSSUnit

Condition1:CablingSequence
1. UptonineODUsmaybeconnectedtothefirstHSSunitusingHSSportsSYNC1,SYNC2,
SYNC3,...uptoSYNC9inorderwithoutleavingemptyports.
2. ThenextavailableSYNCportofthefirstHSSunitshouldbeconnectedtoSYNC10
ofthesecondHSSunitasshowninFigure 144.Intheillustration,thenext
availableportonthefirstHSSunitisSYNC6.
3. ThesecondHSSunitmaybefilledoutwithuptoninemoreODUsinreverseorder.
Thatis,connectSYNC9,SYNC8,SYNC7...asshowninFigure 144.

Figure144:CascadingtwoHSSunits
4. ToaddaafurtherHSSunit:ConnectthenextavailableSYNCportfromthesecond
HSSunitindescendingorder(SYNC5inFigure 144)toSYNC1ofthethirdHSS
unit.
5. ODUsareconnectedtothethirdHSSunitfromSYNC2asshowninFigure 145,in
ascendingorder:

Figure145:CascadingthreeHSSunits

RADWIN5000HPMPUserManual

Release3.5.50

144

ODU/HSSUnitConnectionPinout

6. IffurtherODUsarerequired,observetheconventionthatadditionaleven
numberedunitsarepopulatedindescendingorderfromSYNC9andodd
numberedHSSunitsarepopulatedinascendingorderfromSYNC2.
IfanODUisdisconnectedfromanHSSunit,thenallremainingODUsmust
bemovedupordowntomaintaintheconnectivity.

Note
Condition2:TotalHSSCableLength
ThetotalpathoftheHSSsyncpulsemustnotexceed300m.Thisappliesnomatterhowmany
HSSunitsareused.Toillustratethemethodforcalculatingthesyncpulsepathlengthwe
showthreeexamples.Forourpurpose,let:
LmndenotethelengthoftheODUHSSunitcableatSYNCnonHSSunitm
HmbethelengthofthecablejoiningHSSunitmtoHSSunitm+1
OneHSSunitwithfivecollocatedODUs
PathLength = L 11 + 2 L 12 + 2 L 13 + 2 L 14 + L 15
TwocascadedHSSunitsasshowninFigure 144
PathLength = L 11 + 2 L 12 + 2 L 13 + 2 L 14 +
2 L 15 + H 1 + 2 L 29 + 2 L 28 + 2 L 27 + L 26
ThreecascadedHSSunitsasshowninFigure 145
PathLength = L 11 + 2 L 12 + 2 L 13 + 2 L 14 +
2 L 15 + H 1 + 2 L 29 + 2 L 28 + 2 L 27 + 2 L 26 +
H 2 + 2 L 32 + 2 L 33 + 2 L 34 + L 35

ODU/HSSUnitConnectionPinout
SeeTable B3.

SectorConfigurationandHSS
TheHubSiteSynchronizationSettingsdialogboxappearsintheHBSSiteConfiguration
window.

RADWIN5000HPMPUserManual

Release3.5.50

145

SectorConfigurationandHSS

Figure146:HSSSettingswindow
IfyouclicktheEnabledboxandchooseSerialorSerialandEthernet:

Thecentraldisplay(withOperationalstateopened)willlooklikethis:

RADWIN5000HPMPUserManual

Release3.5.50

146

SyncStatusMessagesandColorCodes

Figure147:SettingHBSasHSMorHSC
ContinueTxmeansthattheHBSasaclienttocontinuetoworkifthereisnoHSMpulse.
IfyouselectHubSyncMasterandclickApply,thedisplaychangesagain:

Figure148:HBSasHSM
SettinguptheHBSasaclientiscarriedoutinasimilarmanner.

SyncStatusMessagesandColorCodes
ThepossibleExternalPulsesconditionsareshowninthefollowingtable:

RADWIN5000HPMPUserManual

Release3.5.50

147

SyncStatusMessagesandColorCodes

Table141:ExternalPulseStatus
Color
code

HSSSyncStatus

Meaning

Generating

ODUisHSMandgeneratesthesyncpulse

Detected

ODUisHSCanddetectsthesyncpulse

Notdetected

ODUisindependent

Generatingand
detected

HSM,butotherHSMpresent

Generatingand
Improperly
Detected

RADWIN5000HBSisHSM,butdetectsaWinLink1000or
RRADWIN2000HSMsignalthatisnotRFPE

Notdetected

HSCbutnoHSMpresent

Improperly
detected

HSCbutHSMpulsedoesntfittheHSCasconfigured.Occurs
Red
onlyforRADWIN5000HBS,whichstopstransmitting.

RADWIN5000HPMPUserManual

Release3.5.50

Green

Orange

148

Chapter15:

HubSiteSynchronizationover
Ethernet
RADWINEthernetHSS
EthernetHSSRequirements
TheRADWINEthernetHubSiteSynchronization(HSSoE)methodprovidesintrasite
synchronizationwithouttheneedforexternalcablesoranHSSunit.Syncsignalsare
exchangedbetweencollocatedradiosovertheregularEthernetconnection.
TheEthernetHSS(HSSoE)methodrequiresLayer2Ethernetconnectivitybetweencollocated
ODUs.Ithastworequirements:
CollocatedODUsprovidingEthernetservicesonly,shouldbeconnectedtoanIDUH
insteadofregularPoEdevices.Othersimpleswitchesmayworkwithdegradedper
formance.Theyarenotrecommendedandproblemsarisingfromtheirusewillnot
beeligibleforanykindofsupport.
CollocatedRADWIN2000classODUsprovidingE1/T1servicesshoulduseanIDUCor
IDUEandthenbeconnectedtoanIDUHfunctioningasaswitch.OneoftheLAN
portsontheIDUCorIDUEisconnectedtoanyofthesixIDUHPoEportsorthetwo
LANports.(ThisispossiblebecausetheIDUCorIDUELANcableonlyusesfourpins
fordata;thepowerpinsarenotusedsothereisnoriskofdamagetothem.)Inthis
way,uptoeightsuchODUsmaybecollocated.

YoumayonlyuseoneIDUH.Thatis,theymaynotbecascaded.

Note

Caution

IfyouareusinganIDUC0(GbE)itmustbeconnectedtotheIDUHLANport
only.ConnectingittotheP0Eportswilldamagetheunitandinanyevent,it
willnotwork.

RADWIN5000HPMPUserManual

Release3.5.50

151

HSSoEConcepts

VLANTaggingshouldnotusetheVLANIDusedbyHSSoEandviceversa.

Caution

HSSoEConcepts
SyncFrames
SyncframesareexchangedbetweencollocatedODUsusingLayer2broadcasting.

Domain
Topreventnetworkflooding,eachgroupofcollocatedODUsisconfiguredwithaninternal
domainname.Thedefaultnamemustbechangedtopreventsyncframesbeingreceived
overtheLANbyanotherODU,whichcouldbethenmistakenlyconfiguredasaclientofan
HSMatthewronglocation.

Discovery
DiscoverybytheHSMandHSCsisprovidedusingthefollowingchoiceoffilters:

UsingdiscoveryattheHSM,youcanselectonlythoseHSCsintheHSMsdomain;when
configuringanewHSCyoumayusediscoverytopickthecorrectHSM.

VLAN
VLANisusedtoseparatesyncframesfromtrafficsoastogivesyncframeshighestpriority.If
youhavecollocatedODUsrunningclosetofullcapacity,failuretodoso,wouldresultin
excessivejitteranddroppedtrafficframes.

RADWIN5000HPMPUserManual

Release3.5.50

152

InstallingCollocatedHSSoEODUs

Bydefault,theVLANID1997andpriority7arereservedforHSS.YoumaychangetheVLANID
butnotthepriority.

InstallingCollocatedHSSoEODUs
EthernetServicesOnly
UseanIDUHforthecollocatedODUsinsteadofseparatePoEdevices.TheIDUHhastwo
LANports,oneofwhichwillbeconnectedtoaswitch.

EthernetandTDMServices
ForRADWIN2000classODUs:ToattainLayer2connectivityforuptotwosuchODUs,you
shouldconnectoneofthetwotheIDUC(orIDUE)LANportstotheIDUHLANports.You
mayusethesecondIDUC(orIDUE)LANporttoconnecttoaswitch.Aspointedoutearlier,
youmayonlycollocatetwoODUsinthisway.

LinkConfigurationandHSSoE
SetupforIllustration
WewillshowhowtosetupourdemonstrationlinkfromManagingtheSectorasHSMand
HSCinturn.(ThesecondcollocatedlinkisaRADWIN2000SCB,thesetupdetailsofwhich,
neednotconcernus).

ConfiguringtheHBSasanHSM

ToconfiguretheMasterODUasEHSSMaster:
1.LogontotheHBS.
2.OpentheConfigure|HubSiteSynctab.

RADWIN5000HPMPUserManual

Release3.5.50

153

ConfiguringtheHBSasanHSM

Figure151:HSSSettingswindow
3.ChecktheEnabledbox.ThegrayedoutbottompartofthewindowinFigure 151is
enabled.

RADWIN5000HPMPUserManual

Release3.5.50

154

ConfiguringtheHBSasanHSM

Figure152:ExtendedProtocolParametersforHSSoE
4.LeavetheOperationstateasisatHubSyncMaster.Hereisthefullrangeofoptions:

Later,wewillneedoneoftheclientoptionsforthecollocatedsite.
5.TheProtocolshouldbeleftasisatEthernet.(Forthemoment,therearenoother
options.)
6.TheDomainistheHSSdomainandreferstothecurrenthubsite.Itisusedto
distinguishbetweenhubsitestopreventinadvertentcollocationtoanovertheair
unit.Wesetitasshown,toPM_Lab.
7.LeavetheVLANIDasisat1977unlessthereissomereasontochangeit.
8.TheDiscoveryoptionsareasfollows:

Figure153:HSSdiscoveryfilters
9.ChooseAll.InourcaseitwillshowtheHBSasHSMandthecollocatedODUasHSC:

RADWIN5000HPMPUserManual

Release3.5.50

155

ConfiguringtheHBSasanHSM

YoucansavetheresultstoatextfileorchangethedisplaytypefromtheDiscovery
windowtoolbar:

ThechoicesarethesameasforFigure 153.
10.UsetheOKorApplybuttonstocommityourchanges.Hereistheoutcome:

RADWIN5000HPMPUserManual

Release3.5.50

156

ConfiguringtheHBSasanHSM

11.ClicktheDetailsbutton.AtableofotherEthernetHSMswiththesamedomainis
displayed:

Thisisamistake:ThereshouldnotbeasecondHSMinthisdomain.Changeittobe
HSCandthedisplayisupdated:

RADWIN5000HPMPUserManual

Release3.5.50

157

ConfiguringtheMasterODUasanHSC

NoticeadditionalHSCatIPaddress10.104.3.2:Itiscollocatedtotheforegoing
radiosusinganHSSunitconnectedtotheHBS.

ConfiguringtheMasterODUasanHSC
WeswitchHSSrolesbetweenourHBSandthecollocatedRADWIN2000SCB.

ToconfiguretheMasterODUasEHSSMaster:
1.Followsteps1to4forconfiguringtheHSM.
2.Atstep5forHSM,chooseHubSyncClientContinueTx.

Hereistheoutcome:

RADWIN5000HPMPUserManual

Release3.5.50

158

SyncStatusMessagesandColorCodes

NotethattheIPaddressoftheHSMisdisplayedforconfirmation.

SyncStatusMessagesandColorCodes
ThepossibleExternalPulsesconditionsareshowninthefollowingtable:
Table151:ExternalPulseStatus
Color
code

HSSSyncStatus

Meaning

Generating

ODUisHSMandgeneratesthesyncpulse

Detected

ODUisHSCanddetectsthesyncpulse

Notdetected

ODUisindependent

Generatingand
detected

HSM,butotherHSMpresent

Generatingand
Improperly
Detected

RADWIN2000SCBisHSM,butdetectsRRADWIN2000HSM Orange
signalthatisnotRFPE

Notdetected

HSCbutnoHSMpresent

Improperly
detected

HSCbutHSMpulsedoesntfittheHSCasconfigured.Occurs
Red
onlyforRADWIN2000C,whichstopstransmitting.

RADWIN5000HPMPUserManual

Release3.5.50

Green

159

Chapter16:

UsingtheRADWINGSU
Whatisitfor
TheGPSbasedsynchronizationunit(GSU)isdesignedtohandleintersiteinterferences
underlargescaledeploymentscenarios.
TheGSUisanoutdoorunitconsistingofasmallsizeenclosure,aGPSantennaandaPoE
device.
ItmaybeoperatedthroughanHSSunitoroverEthernet.
ForuseoverEthernet,theGSUrequiresLayer2connectivitytothemultipleHubSitesthatit
isrequiredtosynchronize.ItsynchronizesthetransmissiontimingoftheseHubSitestothe
sameclocksourcethuseliminatingmutualinterference.Typically,anIDUHisused.

RADWIN5000HPMPUserManual

Release3.5.50

161

GSUFunctionality

Figure161:GeneralGSUconfigurationusingbothEthernetandanHSSunit

GSUFunctionality
TheGSUreceivesasynchronizationsignalfromtheGPSoncepersecond.Itdistributesa
RADWINproprietarysynchronizationsignaltoallotherODUunitsusingaproprietary
synchronizationsignaloverEthernet.
WhentheGSUdoesntreceiveasynchronizationsignalfromtheGPSfor30seconds,itmoves
automaticallytoSelfGenerationmodeuntiltheGPSrecovers.

GSUKitContents
TheGSUpackageincludes:

1xGSU
1xGSUMountingKit
1xGPSAntenna
1xGPSAntennaMountingKit

RADWIN5000HPMPUserManual

Release3.5.50

162

CommissioningandInstallation

1xRFCable,1.5m
RADWINManagersuppliedeitheronCDorbyelectronicmeans

CommissioningandInstallation
PreparingtheGSUforUse
Atthedepot,logontotheunitusingLocalConnectionorIPaddress10.0.0.120tochangeits
IPaddressfromthedefault(10.0.0.120).ThemethodisthesameasisusedforanHBS.Inthe
examplescreencapturesbelow,weuse10.104.20.1withSubnetMask255.255.0.0and
Gateway10.104.10.21.

GSUInstallation
TheGSUlookslikeasmallformfactorODU.MountingtheGSUfollowsthestandardpattern.
TheGPSantennaismountedoutsideonawallorpole.

ConfiguringtheGSU
GettingStarted
ToconfiguretheGSU,youlogontoit,exactlyasinGettingStartedwiththeRADWIN
Manager.

TheGSUMainWindow
HereisthemainwindowforGSUconfiguration:

RADWIN5000HPMPUserManual

Release3.5.50

163

ConfiguringtheGSU

Figure162:GSUMainwidowatstartup
TheGPSsatellitedataiscontainedinthebottomleftpanel:

Figure163:GPSstatusundernormaluse

RADWIN5000HPMPUserManual

Release3.5.50

164

ConfiguringtheGSU

TheConfigurationWindow

Figure164:GSUConfigurationwindow
ThemaintabsofinterestareManagement,HubSiteSyncandGPSSync.
TheManagementtabisthesameasthecorrespondingHBSManagementtab.Ifyousetthe
IPandrelatedaddressescorrectly,thereshouldbelittletochangehere(seeManagement).
Theotherthreetabs,TrapDestination,VLANandProtocolalsohavethesamefunctionhere.
IntheHubSiteSyncwindow,ensurethatitisenabledandtheDomainitemsettobethe
sameasthecorrespondingiteminFigure 152.

RADWIN5000HPMPUserManual

Release3.5.50

165

ConfiguringtheGSU

TheGPSSynctaballowsyoutochooseanRFP(seeHSSConcepts:RadioFramePattern(RFP))
andsettheTransmissionRatioforthesector.Itsvalueisapplicationdependent:

(ThereasonthatthisisdoneattheGSUisthatTransmissionRatiomustalwaysbe
determinedattheunitgeneratingthesyncpulses.)
Foradministrativepurposes,youcanviewtheInventory:
RADWIN5000HPMPUserManual

Release3.5.50

166

ConfiguringtheGSU

RADWIN5000HPMPUserManual

Release3.5.50

167

Part5:AdvancedInstallationTopics

Release3.5.50

Chapter17:

SoftwareBackupandUpgrade
WhatistheSoftwareUpgradeUtility?
TheRADWINManagerprovidesaSoftwareUpgradeUtility(SWU)toupgradethesoftware
(firmware)ofinstalledODUsinanetwork.Theupdatefilesmaybelocatedanywhere
accessiblebytheoperator.
TheSWUprovidesfor:

Priorbackupofthecurrentfilespriortoupgrade
Upgradefromalist
Delayedupgrade
VariousODUresetoptions

Thedefaultlocationofthesoftwarefilesisintheinstallationarea,andcanbeusedtorestore
factorydefaults.

RADWIN5000HPMPUserManual

Release3.5.50

171

UpgradinganInstalledSector

UpgradinganInstalledSector

Toupgradesoftwareforalink:
1.IntheRADWINManager,clicktheSoftwareUpgradebutton.Thefollowingdetached
windowappears:

Figure171:SoftwareUpgradeUtilityMainwindow
ThedefaultsitesshownintheSoftwareUpgradelistpanelbelongtothecurrently
installedsector.ThelistmaybeemptyifyouarerunningtheRADWINManager
offline.
2.TheSoftwareupgradelisttitlebarhasthreebuttonsontherighthandside.

Figure172:Add/Removesitebuttons
TheleftbuttonopensupaWindowsfiledialogtolocatealistoflocationstoupdate.
Thelisthasthefollowingformat:
<IPaddress>,<ReadOnlycommunity>,<ReadWritecommunity>

Forexample:
10.104.50.200,netman
10.104.50.4,netman
10.104.50.2,netman
10.104.50.1,netman
10.104.50.3,netman

RADWIN5000HPMPUserManual

Release3.5.50

172

UpgradinganInstalledSector

ThelistshouldincludeHBSsandHSUsabletoacceptthesameupgrade.Thisis
unlikelytobeaproblemunlessyouareusingequipmentpriortothe3.3.00release
ofRADWIN5000.Nonupgradableitemswillresultinanerrormessage.ContactCus
tomerServiceaboutupgradingthem.
Thecenterbuttonallowsyoutoaddasinglesite:

Figure173:Addingasinglesiteforupgrade
EntertheIPaddressofthesite,theReadWriteCommunity(Default:netman)and
thenclickOK.ThesitewillappearintheSoftwareUpgradelistbox.
Itemsfromthelistcanbeclearedbyselectingthemandthenusingtherightbutton.
TherightbuttoninFigure 173,mayberusetoremoveoneormoreselectedsites.
3.Havingcreatedanupdatelist,clickUpgradePackagetochosetherelevantfiles.The
defaultfilesarelocatedintheSWUsubdirectoryintheRADWINManager
installationarea.YoumayseeoneormoreofthefollowingSWUfiles:
Table171:SWUFilesbyproduct
Filename

Product

SWU_1k.swu

WinLink1000

SWU_2k.swu

RADWIN2000

SWU_5k.swu

RADWIN5000

SWU_gs.swu

RADWINGSU

ForRADWIN5000,alwayschooseSWU_5k.swu.
4.Tobackupyourexistingsystem,checkBackupdevicesoftwarecheckbox.Thenclick
the
buttonforastandardfiledialog.ThedefaultlocationistheMy
Documentsdirectoryonthemanagingcomputerorthelastbackupdirectoryyou
used.

Note

Thebackuphereisthesameasthatonpage 81,andservesthesame
purpose.Itprovidesafallbackiftheupgradeprovesproblematic.Further
informationaboutthebackuputilityisprovidedonpage 175.

RADWIN5000HPMPUserManual

Release3.5.50

173

UpgradinganInstalledSector

5.Inadditiontothepreviousstep,youmayopttoperformadelayedupgrade.Check
theDelayedUpgradebox,andenterthedateandtimeforthedelayedupgrade.A
Calendardialogboxopens:

6.TheradiobuttonsontherightdetermineshowyourHSUsshouldbereset.Bearin
mindthatontheonehand,aresetinvolvesaserviceinterruption,butontheother
hand,thesoftwareupgradewillnotbecomeeffectiveuntilaftertheresetiscarried
out.Hereisatypicaldelayedupgradescenario:

7.ClickStartUpgradetocommencetheprocess.Foranimmediateupgradeyouwillbe
abletoobservetheupgradeprogressfromthegreenprogressbars:

RADWIN5000HPMPUserManual

Release3.5.50

174

BulkSoftwareBackup

Figure174:SoftwareupgradeinprogressNotethestopbutton

Figure175:Softwareupgradecompletedsuccessfully
8.UsethetitlebarexitbuttontodismisstheSoftwareupgradewindow..

Caution

Ifanysitesfailtoupdate,awarningnoticewillbedisplayed.
Ifoneormoresitesofasectorupdatefails,youshouldcorrecttheproblem
andupdatethefailedsitesassoonaspossible.Ifyoudonot,followingthe
nextresetoftheupdatedsites,youcouldexperiencealinksoftware
mismatchwhichmayaffectservice.

BulkSoftwareBackup
YoucanbackupthesectorsoftwareindependentlyofSoftwareUpgradeusingtheHBSmain
buttonmenu.

RADWIN5000HPMPUserManual

Release3.5.50

175

BulkSoftwareBackup

TheBulkBackuptabopensthefollowingwindow:

Figure176:BulkBackupsetupwindow
Themethodofselection,additionorremovalofitemsfollowsthesamepatternasinSWU
selection,Figure 171.
Saveconfigurationproducesatextfileintheformatforupgradinganinstalledsector,asin
theexampleonpage 172.

RADWIN5000HPMPUserManual

Release3.5.50

176

Chapter18:

VLANFunctionalitywith
RADWIN5000HPMP
VLANTaggingOverview
VLANTerminology
BoththetechnicalliteratureandtheRADWINManagerusethetermsVLANIDandVID
interchangeablytodenoteaVLANidentificationnumber.

VLANBackgroundInformationontheWeb
ThestandardsdefiningVLANTaggingareIEEE_802.1Qandextensions.
ForgeneralbackgroundaboutVLANseehttp://en.wikipedia.org/wiki/Virtual_LAN.
BackgroundinformationaboutDoubleTaggingalsoknownasQinQmaybefoundhere:
http://en.wikipedia.org/wiki/802.1QinQ.

ScopeofthisChapter
ThischapterdescribeshowthecomponentsofaRADWIN5000HPMPsectordealwith
tagginganduntagging.

Requirements
ItisassumedthatyouarefamiliarwithVLANusageandterminology.

RADWIN5000HPMPUserManual

Release3.5.50

181

VLANTagging

VLANTagging
VLANtaggingenablesmultiplebridgednetworkstotransparentlysharethesamephysical
networklinkwithoutleakageofinformationbetweennetworks:

Figure181:VLANscenarioshandledbyRADWIN5000HBS
IEEE802.1Qisusedastheencapsulationprotocoltoimplementthismechanismover
Ethernetnetworks.

QinQ(DoubleTagging)forServiceProviders
QinQisusefulforServiceProviders,allowingthemtouseVLANsinternallyintheirtransport
networkwhilemixingEthernettrafficfromclientsthatarealreadyVLANtagged.

RADWIN5000HPMPUserManual

Release3.5.50

182

VLANUntagging

Figure182:Separatingclientdatastreamsusingdoubletagging
Theoutertag(representingtheProviderVLAN)comesfirst,followedbytheinnertag.InQinQ
theEtherType=0x9100.VLANtagsmaybestackedthreeormoredeep.
WhenusingthistypeofProviderTaggingyoushouldkeepthefollowinginmind:

UnderProviderTagging,thesystemdoubletagsegressframestowardstheProviders
network.ThesystemaddsatagwithaVLANIDandEtherType=0x9100toallframes,as
configuredbytheserviceprovider(ProviderVLANID).
Thesystemalwaysaddstoeachframe,tagswithVLANIDandEtherType=0x9100.
Therefore,
ForaframewithoutatagthesystemwilladdatagwithVLANIDandEtherType=
0x9100sotheframewillhaveonetag
ForaframewithaVLANtagthesystemwilladdatagwithVLANIDandEtherType
=0x9100sotheframewillbedoubletagged

ForaframewithaVLANtagandaprovidertagthesystemwilladdatagwithVLANIDand
EtherType=0x9100sotheframewillbetripletaggedandsoon.
Attheegressside,theHSUremovestheQinQtagwithEtherType=0x9100nomatterwhat
thevalueofitsVLANID.

VLANUntagging
VLANUntaggingmeanstheremovalofaVLANoraProvidertag.

PortFunctionality
InaRADWIN5000sector,allVLANactivityisconfiguredandsupportedfromtheHSUs.
RADWIN5000HPMPUserManual

Release3.5.50

183

PortFunctionality

Tothisend,VLANfunctionalityissupportedattheMNGportoftheHSU.
TheHSUMNGportcanbeconfiguredtohandleEthernetframesattheingressdirection
(whereframesentertheHSU)andattheegressdirection(whereframesexittheHSU).

RADWIN5000HPMPUserManual

Release3.5.50

184

PortFunctionality

IngressDirection
Table181:PortsettingsIngressdirection
Transparent

TheportdoesnothingwithregardtoVLANsinboundframesareleft
untouched.
FramesenteringtheHSUportwithoutVLANorQinQtaggingaretaggedwith
VLANIDandPrioritya,whicharepreconfiguredbytheuser.Frameswhichare
alreadytaggedatingressarenotmodifiedandpassthrough.

Tag

FramesenteringtheHSUportaretaggedwithprovidersVLANIDand
Prioritywhicharepreconfiguredbytheuser.Frame.swhicharealready
taggedwithProvidertaggingattheingressarenotmodifiedandpassed
through
Providertag

.
a. Priority

Code Point (PCP) which refers to the IEEE 802.1p priority. It indicates the frame priority level
from 0 (lowest) to 7 (highest), which can be used to prioritize different classes of traffic (voice, video,
data, etc).

RADWIN5000HPMPUserManual

Release3.5.50

185

VLANConfigurationUsingtheRADWINManager

EgressDirection
Table182:PortsettingsEgressdirection
Transparent

TheportdoesnothingwithregardtoVLANsoutboundframesareleft
untouched.
PortconfiguredtountaguserVLADtagsforallframes.

Untagall

Filter

VLANConfigurationUsingtheRADWIN
Manager

Disclaimer

IfyouarenotaVLANexpert,pleasebeawarethatincorrectVLAN
configurationmaycausehavoconyournetwork.Thefacilitiesdescribed
belowareofferedasaservicetoenableyoutogetbestvaluefromyour
RADWIN5000HPMPlinksandareprovidedasis.Undernocircumstances
doesRADWINacceptresponsibilityfornetworksystemorfinancial
damagesarisingfromincorrectuseoftheseVLANfacilities.

ManagementTrafficandEthernetServiceSeparation
YoucandefineaVLANIDformanagementtrafficseparation.Youshouldconfigurethesystem
topreventconflictsasdetailedbelow.
Whenconfiguredforthedefaultoperationalmode,aProviderportwillhandleingress
trafficasfollows:

FiltersframesthatarenottaggedwiththeProviderVLANID
RemovestheProviderdoubletag

Therefore,ifaportisconfiguredformanagementtrafficseparationbyVLANandasProvider
port,thenthereceivedmanagementframesmustbedoubletaggedasfollows:

RADWIN5000HPMPUserManual

Release3.5.50

186

ManagingtheHBSovertheAirfromanHSU

TheoutertaghastobetheProviderstag(sotheframeisnotfiltered)
TheinternaltaghastobemanagementVLANID

Toavoidmixups,bestpracticeisto:

Separatethemanagementanddataports
DefineonlyadataportwithProviderfunction

ManagingtheHBSovertheAirfromanHSU
IftrafficVLANtaggingisinforcefortheHSUingressdirectionandmanagementVLANisinuse
attheHBS,thentheVLANIDattheHSUingressdirectionmustbethesameastheVLANID
formanagementattheHBS.

ConfigurationofVLANTaggingforEthernetService
VLANconfigurationiscarriedoutperHSU.Itisuptoyoutoensureconsistencybetweenthe
HSUs.
HSUVLANtaggingcanonlybeconfiguredfromone of the HSU views from the HBS.Youcan
notlogontoanHSUdirectlyanddoitfromtheHSUmainwindow.ThereasonisthattheHSU
maintainstheHSUtagginginformationinitsinternalperHSUconfigurationrecord.

TosetupanHSUforVLANtagging:
1.RightclickanHSUontheHBSwindow,andthenclickConfigure|Ethernet|VLAN
Configuration.TheVLANConfigurationwindowisdisplayed:

RADWIN5000HPMPUserManual

Release3.5.50

187

ConfigurationofVLANTaggingforEthernetService

InDisabledmode,Ethernetframespasstransparentlyovertheradiolinks.
2.ForProvidertagging,clicktheProviderRadiobutton:

InProvidermode,EthernetframesaretaggedwiththeprovidersVLANIDbefore
theyenterintotheprovidersnetwork/backbone.

RADWIN5000HPMPUserManual

Release3.5.50

188

ConfigurationofVLANTaggingforEthernetService

3.EnteraProviderVLANIDandPriority.TheVLANIDmustbeintherange2to4094.
TheVLANPrioritymustbeintherange0to7.YoumayalsochangetheTPIDfrom
thedefaultasshown.
Thisfacilityisprovidedtoenableconnectionthroughlegacyswitches
requiringit.Otherwise,thereisnoneedtochangetheTPID.

Note
4.ClickOKtoaccept.
5.ForuserVLANtagging,clicktheTagRadiobutton:

InTagmodeEthernetframesaretaggedoruntaggedtodistinguishbetweendiffer
entnetworks.
6.Forcompletelytransparentpassageoftaggedframes,thereisnothingfurthertodo.
ThefollowingtableshowsthepossiblesettingsforeachcombinationofIngressand
Egressmodes:

RADWIN5000HPMPUserManual

Release3.5.50

189

ConfigurationofVLANTaggingforEthernetService

7.ClickOK.
Table183:FurtherVLANConfigurationoptionsandresultsbyTagmode
Egress
Ingress

Transparent

Tag:

EnteraVID(1
4094)and
Priority(07)

Transparent

UntagAll

UntagFiltered

Filter

AllowVLANIDs:
Framesare
Allowupto4VIDs
notmodified
Allframeswith tobepassed
Allowupto4VIDs
andare
through.
VLANtagare
tobepassed
forwarded
UntagVLANIDs:
untagged
through.
transparentl
UntagtheVLAN
y
tagoftheselected
VLANIDs.
Framesare
notmodified
Allframeswith Allowupto4VIDs Allowupto4VIDs
andare
VLANtagare
tobepassed
tobepassed
forwarded
untagged
through
through
transparentl
y

RADWIN5000HPMPUserManual

Release3.5.50

1810

Chapter19:

FalseRadarMitigation
Facilities
Whoneedsit
IfyouareusingDFSfrequencybands5.3/5.4GHzETSIand5.4/5.8GHzFCCyoushouldusethis
facility.

DFSandFalseRadarMitigation
AboutDFS
UnderDFSfrequencybands,itmustbeensuredthatradiolinksdonotinterferewithcertain
radarsystemsinthe5GHzband.Ifradarisdetected,theradiolinkshouldmove
automaticallytoafrequencythatdoesnotinterferewiththedetectedradar.

WhatisFalseRadarMitigation
FalseRadarMitigationcapabilityisanadvancedmethodtoreduceoreliminatefalseradar
detectionandDFStriggering(Falsepositives).
Falseradardetectioncanbecausedbyotherradiostransmissionsorexternalinterference
thatcanbeinterpretedastrueradar.
ThisoptionisactiveonlyinDFSfrequencybands,5.3/5.4GHzFCC(HBSonly)and5.4/5.8GHz
ETSI(HBS&HSU).
Inwhatfollowsfalseradarmeansanysourceofradarlikesignalswhicharenotrealradar.
FalseRadarMitigationhastwocomponents:
1. Reductionoffalsepositiveradardetectionbyreductionoftheprobabilityofdetectingany
kindoffalseradars,whileallowingthesystemtodetectrealradarsignals.

RADWIN5000HPMPUserManual

Release3.5.50

191

ConfiguringFalseRadarMitigation

2. Eliminationofdetectionofspecificfalseradartypesbyblockingdetectionoffalseradars
ofaspecifictype.Therearethreetypesofradars:
Fixed:Falseradarswithfixedpulsewidthhavingfixedrepetitionfrequency
Variable:Falseradarswithvariablepulsewidthhavingvariablerepetitionfrequency
Staggered:Falseradarswithvariablerepetitionfrequencywithinaburstperiod
(Appliesto5.4GHzETSIonly)

ConfiguringFalseRadarMitigation
TheconfigurationmethodfortheHBS(ETSIandFCC/IC)isthesameasfortheHSUs(ETSI
only).WewilldemonstratetheHBSforasectorusingthe5.3GHzFCC/ICband:

ToconfigureFalseRadarMitigation:
1.LogontotheHBSasInstaller.
2.EntertheConfigurationwindowandopentheAdvancedtab.

Figure191:FalseRadarMitigation

RADWIN5000HPMPUserManual

Release3.5.50

192

FCC/ICRequirements

3.TheDFSFrequencyStatusTableatthebottomofFigure 191showsthetime,type
andfrequencyofthelastradarsdetected.Thistableshouldbeusedtoselectthe
bestoption(s)toreduceoreliminatefalseradardetectionwithoutcompletely
blockingoutrealradardetection.
4.Checkthemitigationfeaturestobeused.
5.Whenyouaresatisfiedwithyourconfigurationparameters,clickOKtosavethem
anddismisstheConfigurationwindow.

FCC/ICRequirements
TheFCCrequiresthatdevicesinstalledwithin35kmofanyTerminalDopplerWeatherRadars
(TDWR)locationshouldberegisteredinthevoluntaryWISPAsponsoreddatabase.For
convenience,wesupplyguidelinesaboutthewaythisisdoneinChapter20.

RADWIN5000HPMPUserManual

Release3.5.50

193

Chapter20:

FCC/ICDFSConsiderations
FCC5.4GHzDeviceRegistration
TheFCCrequiresthatdevicesinstalledwithin35kmofanyTDWRlocationshouldbe
registeredinthevoluntaryWISPAsponsoreddatabase.
TheFCChaspublishedaTDWRLocationInformationtablethatliststheexactlocationofall
TDWRtowers(seeTable 201attheendofthechapter).
1. Wheninstallinga5.4GHzdevicedefineyourexactlocation(latitudeandlongitude)
2. UsetheTDWRLocationInformationtabletodetermineifthedistancebetween
thedeviceandanyTDWRtowerislessthan35km.
3. Ifthedistanceislessthan35kmthenregisterthedeviceinthevoluntaryWISPA
sponsoreddatabase(followingsection)
4. Disablethefrequenciesbetween55705680MHzfromtheavailablechannels
list.
5. Thefrequencyrangebetween5.600to5.650GHzisnotincludedintheavailable
channelslist.

RegisteringtheDevice

Toregisteradevice:
1.Enterthewebsitehttp://www.spectrumbridge.com/udia/home.aspxandfollowthe
instructions.
Atyourfirstentryintothesite,youwillberequiredtoregisterasauser:

RADWIN5000HPMPUserManual

Release3.5.50

201

RegisteringtheDevice

2.ClicktheUserRegistrationbuttontoentertheregistrationpage.

RADWIN5000HPMPUserManual

Release3.5.50

202

RegisteringtheDevice

3.FillintheregistrationpageandclickRegister.
4.TocompletedeviceregistrationentertheRegisterDevicetabasshown:

RADWIN5000HPMPUserManual

Release3.5.50

203

RegisteringtheDevice

Youareofferedthis:

5.FillintherequiredinformationintheprecedingwebpageandclicktheRegister
Devicebutton.

RADWIN5000HPMPUserManual

Release3.5.50

204

TDWRTable

TDWRTable
ThefollowingtablecontainsthelatitudeandlongitudelocationsofTerminalDoppler
WeatherRadars(TDWR).UsethistabletodetermineiftheMasterorClientdeviceinstalledis
within35kmradiusofaTDWRlocation.Ifoneoftheinstalleddevicesiswithin35kmradius
ofanyTDWRlocationthendisableallfrequenciesbetween55705680MHzfromthe
availablechannelslist.
Table201:LatitudeandlongitudelocationsofTDWRs
STATE

CITY

LONGITUDE

LATITUDE

FREQUENCY

TERRAINELE
VATION
(MSL)[ft]

ANTENNA
HEIGHT
ABOVETER
RAIN[ft]

AZ

PHOENIX

W1120946

N332514

5610MHz

1024

64

CO

DENVER

W1043135

N394339

5615MHz

5643

64

FL

FTLAUDERDALE

W0802039

N260836

5645MHz

113

FL

MIAMI

W0802928

N254527

5605MHz

10

113

FL

ORLANDO

W0811933

N282037

5640MHz

72

97

FL

TAMPA

W0823104

N275135

5620MHz

14

80

FL

WESTPALMBEACH

W0801623

N264117

5615MHz

20

113

GA

ATLANTA

W0841544

N333848

5615MHz

962

113

IL

MCCOOK

W0875131

N414750

5615MHz

646

97

IL

CRESTWOOD

W0874347

N413905

5645MHz

663

113

IN

INDIANAPOLIS

W0862608

N393814

5605MHz

751

97

KS

WICHITA

W0972613

N373026

5603MHz

1270

80

KY

COVINGTONCINCINNATI

W0843448

N385353

5610MHz

942

97

KY

LOUISVILLE

W0853638

N380245

5646MHz

617

113

LA

NEWORLEANS

W0902411

N300118

5645MHz

97

MA

BOSTON

W0705601

N420930

5610MHz

151

113

MD

BRANDYWINE

W0765042

N384143

5635MHz

233

113

MD

BENFIELD

W0763748

N390523

5645MHz

184

113

MD

CLINTON

W0765743

N384532

5615MHz

249

97

MI

DETROIT

W0833054

N420640

5615MHz

656

113

MN

MINNEAPOLIS

W0925558

N445217

5610MHz

1040

80

MO

KANSASCITY

W0944431

N392955

5605MHz

1040

64

MO

SAINTLOUIS

W0902921

N384820

5610MHz

551

97

MS

DESOTOCOUNTY

W0895933

N345345

5610MHz

371

113

NC

CHARLOTTE

W0805306

N352014

5608MHz

757

113

NC

RALEIGHDURHAM

W0784150

N360007

5647MHz

400

113

NJ

WOODBRIDGE

W0741613

N403537

5620MHz

19

113

NJ

PENNSAUKEN

W0750412

N395657

5610MHz

39

113

NV

LASVEGAS

W1150026

N360837

5645MHz

1995

64

RADWIN5000HPMPUserManual

Release3.5.50

205

TDWRTable

Table201:LatitudeandlongitudelocationsofTDWRs(Continued)
STATE

CITY

LONGITUDE

LATITUDE

FREQUENCY

TERRAINELE
VATION
(MSL)[ft]

ANTENNA
HEIGHT
ABOVETER
RAIN[ft]

NY

FLOYDBENNETTFIELD

W0735249

N403520

5647MHz

97

OH

DAYTON

W0840723

N400119

5640MHz

922

97

OH

CLEVELAND

W0820028

N411723

5645MHz

817

113

OH

COLUMBUS

W0824255

N400020

5605MHz

1037

113

OK

AERO.CTRTDWR#1

W0973731

N352419

5610MHz

1285

80

OK

AERO.CTRTDWR#2

W0973743

N352334

5620MHz

1293

97

OK

TULSA

W0954934

N360414

5605MHz

712

113

OK

OKLAHOMACITY

W0973036

N351634

5603MHz

1195

64

PA

HANOVER

W0802910

N403005

5615MHz

1266

113

PR

SANJUAN

W0661046

N182826

5610MHz

59

113

TN

NASHVILLE

W0863942

N355847

5605MHz

722

97

TX

HOUSTONINTERCONTL

W0953401

N300354

5605MHz

154

97

TX

PEARLAND

W0951430

N293059

5645MHz

36

80

TX

DALLASLOVEFIELD

W0965806

N325533

5608MHz

541

80

TX

LEWISVILLEDFW

W0965505

N330353

5640MHz

554

31

UT

SALTLAKECITY

W1115547

N405802

5610MHz

4219

80

VA

LEESBURG

W0773146

N390502

5605MHz

361

113

WI

MILWAUKEE

W0880247

N424910

5603MHz

820

113

RADWIN5000HPMPUserManual

Release3.5.50

206

Chapter21:

QualityofService
Prerequisites
TousethefacilityyoumustbefamiliarwiththeuseofVLAN(802.1p)orDiffserv.

QoSOverview
QoSisatechniqueforprioritizationofnetworktrafficpacketsduringcongestion.
RADWIN5000sectorssupporttwoclassificationcriteria,VLANbasedorDiffservbased.You
maychoosewhichofthemtouse.
Table211:DefaultprioritiesandallocationbyVLANIDandDiffserv
Priority

Qualityqueue

Diffserv

VLAN

Realtime

4863

67

Nearrealtime(responsive
applications)

3247

45

Controlledload

1631

23

Besteffort

015

01

Basedupontheclassificationcriterionchosen,receivedpacketswillbemappedintooneof
fourqualitygroups:Realtime,Nearrealtime,ControlledloadandBesteffort.
YoumaypartitionthetotallinkcapacityacrossthefourQualityqueues.Thedefaultweights
aspercentagesareshowninTable 211.

SettingupQoS
QoSforRADWIN5000issetupintwophases:
RADWIN5000HPMPUserManual

Release3.5.50

211

SettinguptheHBSforQoS

1. Therequiredqueuesforthesectorandtheirrespectiveprioritymappingsmustbechosen.
2. ForeachHSUyoumustconfiguretherequiredqueues,queueweightsandqueueMaxi
mumInformationRate(MIR).ThelattermustbedoneforboththeUplinkandDownlink
directions.

SettinguptheHBSforQoS
FromtheHBSmanager,enterConfiguration,opentheEthernettabandthenQoS
configuration.QoSisdisabledbydefault.YoumaychoosebetweentheVLAN(802.1p)and
Diffservmethods.

ThedefaultsettingsforDiffservandVLANareasshowninthenexttwofigures:

RADWIN5000HPMPUserManual

Release3.5.50

212

SettingupanHSUforQoS

Ifyouuncheckaqueue,itwillbedisabledforthesector.ItwillnotpreventtheHSUfrom
configuringitaslive.ThepurposebehindthisistoavoidthenecessityofreconfiguringQoS
foreachHSU,shouldthequeuebereinstated.

SettingupanHSUforQoS
QoSsetupforanHSUiscarriedoutfromtheHBS.

ToconfigureanHSUforQoS:
1.RightclickanHSUintheHBSmanagerHSUwindow,andchooseConfiguration.
2.OpentheEthernettabandclickQoSConfiguration.Thefollowingwindowis
displayed:

3.EnsurethattheModefieldisEnabled.IfyoualreadyconfiguredtheHBS(sector)for
DiffservorVLAN,thenitwillbeenabledbydefault.Ifyouneedtochangethemode,
thenyouprobablydidnotsetthesectorwideQoStypebutyoucangobackanddo
itlater.
RADWIN5000HPMPUserManual

Release3.5.50

213

SettingupanHSUforQoS

4.Foreachqueue,bothdownlinkanduplink(fromtheHSU)entertherequiredweight
andMIR.Thelattermaybeleftunlimited.inwhichcasethesystemwilluseabest
effortmethod.
Ifyouexceed100%totalweight,youwillreceiveanerrormessage.

Youwillberequiredtocorrectthisbeforeleavingthewindowotherthanbycancel
lation.
Ifyouareunderbooked,forexamplebysettingaqueuetozero,theunusedweight
willbedistributedtotheremainingqueues.Theeffectofdoingthiswillonlybecome
apparentundercongestion.Inparticular,aqueuesettozeroweightwillbecome
nearlyblockedundercongestionwithpacketspassingthroughonabesteffortbasis.
5.UsingtheConfigurableTTL:ConfigurableTimetoLive(TTL)istypicallyusedfor
streamingapplicationslikemannedvideosurveillance.Apacketnottransmitted
withintheTTLperiodinacongestedlinkisdropped.Inthemannedvideo
surveillanceexample,thelossofpacketsundercongestionislessimportantthan
acquiringthemostrecentpackets.ThechoiceoftheTTLdurationistherefore,
dependentonthetoleranceoftheuserapplicationtotransmissionglitches.
6.Whenyoucompleteyourentries,clickOKtosavethemandcontinue.

RADWIN5000HPMPUserManual

Release3.5.50

214

Chapter22:

CapacityUpgrade
WhatisCapacityUpgrade
AnHSUmayhaveitscapacityincreasedbyapplicationofanupgradelicensekey.The
currentlyavailableupgradepathsare5Mbpsto10Mbps,5Mbpsto25Mbpsand10Mbpsto
25Mbps.Thecapacityupgradeprocessconsistsofthreesteps:

DataGatheringpreparationofalistofHSUsforupgradebyserialnumber
Acquisitionpurchasingtheupgradelicensekeys
ApplicationactivatingthecapacityupgradeusingtheRADWINManager

Applicability
CapacityupgradeisonlyavailableforfixedHSUsandnomadicHSUs.

DataGathering
Openthesectorlistview:

RADWIN5000HPMPUserManual

Release3.5.50

221

DataGathering

SelectalloftheHSUsandthenclickthecircledbutton.AsectorlistshowingdetailsoftheHBS
andalloftheHSUsissavedtotheclipboard.Youmayrecoveritasatextfileinanytexteditor.
Thebestviewisobtainedbysavingittoaanemptyspreadsheet.Hereforexample,isour
demonstrationconfiguration(withirrelevantcolumnssquashedtosavespace):

ExtractasubtableconsistingoftherelevantHSUs(inourexample,theredrectangles):

RADWIN5000HPMPUserManual

Release3.5.50

222

Acquisition

PrepareatablesimilartoTable 221:
Table221:HSUCapacityUpgradeList
HSUName
(1)

HSUSerialNumber
(2)

Brahms@HNU.01.01

PIN580I500A00003

Haydn@HFU.01.01

PIN580I500A00004

Mozart@HFU.01.02

PIN580I500A00005

CapacityUpgradeKey
(3)

Columns1isforyourownconvenience.Lateryouwillcopy/pastethecapacityupgradekey
intocolumn3asapermanentconvenientrecord.

Acquisition
SendthesupplierofyourequipmentaPurchaseOrderforyourCapacityUpgradeList(Use
eithertheoriginaltext/spreadsheetfileorcolumn2ofTable 221).Ensurethatyouincludea
currentemailaddressforreceiptofthekeylist.Uponcompletionoftheorder,youwill
receiveanemailwithanattachedlistconsistingofserialnumbersandalicencekeyperserial
number.Thelicencekeysarequitelonganditisimportantthatyoureceivethemin
electronicformatforsubsequentcopy/pasting.

Application
IndividualHSUCapacityUpgrade
ThefollowingprocedurecanbecarriedoutbydirectconnectiontoanHSU(typicallynot
activeinasector)orfromtheHBS.
UsingyourcompletedCapacityUpgradetable(orthesuppliedemail)andforeachHSUin
turn,opentheConfiguration|Operationswindow.(YoumaydothisfromtheHBSorby
directconnectionwhateverismostconvenient.)CopypastethelicensekeytotheLicense
Keyfield.ClicktheActivatebutton(willbecomesenabled).

RADWIN5000HPMPUserManual

Release3.5.50

223

Bulk(Sector)HSUCapacityUpgrade

Youwillreceiveaconfirmatorymessageiftheactivationsucceededoranerrormessageif
not.Inthelattercase,youwillneedtobeincontactwithyourequipmentsuppliertosolve
theproblem.

Bulk(Sector)HSUCapacityUpgrade
IfalltheHSUsarepartofasector(registeredornot),youmaybulkupgradeallofthe
memberHSUsfromthesuppliedtextfileattachedtotheemailyoureceivedfromyour
supplier.Saveittoaconvenientlocationforlateruse.
GotoheConfiguration|OperationswindowfortheHBSitself(ratherthaneachHSU
separately).UsetheLicenseFileoptiontonavigatetoyourtextfile.ClicktheActivatebutton,
whichisnowenabled.
Again,paycarefulattentiontotheconfirmationorerrormessages.

CompletingtheCapacityUpgrade
Tomaketheupgradeeffective,eachupgradedHSUmustbereset.

PersistencyoftheCapacityUpgrade
TheupgradeispersistentacrossanHSUreset.Ifhowever,yourestoreacapacityupgraded
HSUtofactorydefaults,youwillneedtoapplythecapacityupgradetoitagain.Thisfurther
underlinestheimportanceofsavingthelicensekeysattachmentfileinasafeplaceand
maintainingarecordlikeTable 221.

RADWIN5000HPMPUserManual

Release3.5.50

224

Part6:FieldInstallationTopics

Release3.5.50

Chapter23:

LinkBudgetCalculator
Overview
TheLinkBudgetCalculatorisautilityforcalculatingtheexpectedperformanceofthe
RADWIN5000HPMPwirelesslinkwithinasectorandthepossibleconfigurationsfora
specificlinkrange.
TheutilityallowsyoutocalculatetheexpectedRSSofthelink,andfindthetypeofservices
andtheireffectivethroughputasafunctionofthelinkrangeanddeploymentconditions.

UserInput
Youarerequiredtoenterorchoosethefollowingparameters.Dependingontheproduct,
someoftheparametershaveadefaultvaluethatcannotbechanged.

Band,whichdeterminesfrequencyandregulation
HSUseriesused
ChannelBandwidth(currently10and20MHz)
TxPower(maximumTxpowerpermodulationisvalidated)
AntennaType(currentlydual;cannotbechangedforODUwithintegratedantenna)
AntennaGainpersite(cannotbechangedforintegratedantenna)
CableLosspersite(cannotbechangedforintegratedantenna)
FadeMargin(currently6dB)
Rate
RequiredRangeandclimatetype

LinkBudgetCalculatorInternalData
Foreachproduct(orRegulationandBand)thecalculatorstoresthefollowingdatarequired
forlinkbudgetcalculations:

MaximumTransmitpower(permodulation)
ReceiverSensitivity(permodulation)forEthernetservice

RADWIN5000HPMPUserManual

Release3.5.50

231

Calculations

Maximumlinearinputpower(usedtocalculateminimumdistance)
AntennagainandcablelossforODUwithintegratedantenna
AvailableChannelBandwidths

Calculations
EIRP
EIRP = TxPower + AntennaGain SiteA CableLoss SiteA

ExpectedRSSandFadeMargin
ExpectedRSS = EIRP PathLoss + AntennaGain SiteB CableLoss SiteB
where:
SiteAisthetransmittingsite
SiteBisthereceivingsite
PathLossiscalculatedaccordingtothefreespacemodel,
PathLoss = 32.45 + 20 log 10 frequency MHz + 20 log 10 RequiredRange Km
ExpectedFadeM arg in = ExpectedRSS Sensitivity
whereSensitivityisdependentonairrate.

MinandMaxRange
MinRangeistheshortestrangeforwhich ExpectedRSS MaxInputPower perairrate.
MaxRange(withAdaptivechecked)isthelargestrangeforwhich
ExpectedRSS Sensitivity ,atthehighestairrateforwhichthisrelationshipistrue.Ina
linkwithadaptiveratethiswillbetheactualbehavior.
MaxRange(foragivenairrate)isthelargestrangeforwhich
ExpectedRSS Sensitivity + RequiredFadeM arg in .

Service
TheEthernetandconfiguredTDMtrunksthroughputiscalculatedaccordingtointernal
productalgorithms.

Availability
TheServiceAvailabilitycalculationisbasedontheVigantsBarnettmethodwhichpredictsthe
downtimeprobabilitybasedonaclimatefactor(Cfactor).
RADWIN5000HPMPUserManual

Release3.5.50

232

AntennaHeight

Availability
= 1 6 10
10

Cfactor frequency GHz RequiredRange KM

----------------------------------------------------------ExpectedFadeM arg in10

AntennaHeight
Therecommendedantennaheightrequiredforlineofsightiscalculatedasthesumthe
Fresnelzoneheightandtheboresightheight.SeeAbouttheFresnelZonebelow.Usingthe
notationofFigure 231below,splittingExpectedRangeintod1+d2,theFresnelzoneheight
atdistanced1fromthelefthandantenna,isgivenby
300
---------------------------------- d1 d2
frequency GHz
0.6 ----------------------------------------------------------d1 + d2
Forthemostconservativesetting,wetakethemidpointbetweentheantennas,setting
ExpectedRange
d 1 = d 2 = ----------------------------------------2
2
300
---------------------------------- ExpectedRange
----------------------------------------frequency GHz
2
whichgives 0.6 ------------------------------------------------------------------------------------------ExpectedRange
ExpectedRange
----------------------------------------- + ----------------------------------------2
2

ExpectedRange
simplifyingto 0.52 ----------------------------------------- .
frequency GHz
Theboresightclearanceheightiscalculatedas: R

Mean

ExpectedRange
+ ----------------------------------------2

R Mean

where R Mean = 6367.4425Km .

AbouttheFresnelZone
TheFresnelzone(pronounced"frAnel",withasilents)isanellipticallyshapedconicalzone
ofelectromagneticenergythatpropagatesfromthetransmittingantennatothereceiving
antenna.Itisalwayswidestinthemiddleofthepathbetweenthetwoantennas.

RADWIN5000HPMPUserManual

Release3.5.50

233

AbouttheFresnelZone

Figure231:Fresnelzone
Fresnellossisthepathlossoccurringfrommultipathreflectionsfromreflectivesurfaces
suchaswater,andinterveningobstaclessuchasbuildingsormountainpeakswithinthe
Fresnelzone.
Radiolinksshouldbedesignedtoaccommodateobstructionsandatmosphericconditions,
weatherconditions,largebodiesofwater,andotherreflectorsandabsorbersof
electromagneticenergy.
TheFresnelzoneprovidesuswithawaytocalculatetheamountofclearancethatawireless
waveneedsfromanobstacletoensurethattheobstacledoesnotattenuatethesignal.
ThereareinfinitelymanyFresnelzoneslocatedcoaxiallyaroundthecenterofthedirect
wave.TheouterboundaryofthefirstFresnelzoneisdefinedasthecombinedpathlengthof
allpaths,whicharehalfwavelength(1/2)ofthefrequencytransmittedlongerthanthe
directpath.Ifthetotalpathdistanceisonewavelength(1)longerthanthedirectpath,then
theouterboundaryissaidtobetwoFresnelzones.OddnumberFresnelzonesreinforcethe
directwavepathsignal;evennumberFresnelzonescancelthedirectwavepathsignal.
TheamountoftheFresnelzoneclearanceisdeterminedbythewavelengthofthesignal,the
pathlength,andthedistancetotheobstacle.Forreliability,pointtopointlinksaredesigned
tohaveatleast60%ofthefirstFresnelzonecleartoavoidsignificantattenuation.
TheconceptoftheFresnelzoneisshowninFigure 231above.Thetopoftheobstruction
doesnotextendfarintotheFresnelzone,leaving60%oftheFresnelzoneclear;therefore,
thesignalisnotsignificantlyattenuated.
FormoreaboutFresnelzone,seehttp://en.wikipedia.org/wiki/Fresnel_zone.

RADWIN5000HPMPUserManual

Release3.5.50

234

RunningtheLinkBudgetCalculator

RunningtheLinkBudgetCalculator
TheLinkBudgetCalculatorissuppliedontheRADWINManagerCD.Itmayberunstand
alonefromtheCDorfromtheRADWINManagerapplication.

ToruntheLinkBudgetCalculatorfromtheCD:
1.InserttheRADWINManagerCDintothedriveonthemanagingcomputer.Inthewin
dowwhichopens,clicktheLinkBudgetCalculatoroption.
2.IftheCDautorunapplicationdoesnotstartbyitself,thenpointyourbrowserto
Z:\RADWIN\Setup\DATA\LinkBudgetCalculator.htm
whereZshouldbereplacedwithyourownCDdrivename.

ToruntheLinkBudgetCalculatorfromtheRADWINManager:
ChooseHelp|LinkBudgetCalculatorfromthemainmenuoftheRADWINManager:

Figure232:AccessingtheLinkBudgetCalculator

ToruntheLinkBudgetCalculatorfromtheWindowsStartMenu:
GotoStart|Programs|RADWINManager|LinkBudgetCalculator

Howeverinvoked,yourbrowserdisplaysthefollowingpage(shownpartially):

Figure233:LinkBudgetwindowstartup

RADWIN5000HPMPUserManual

Release3.5.50

235

RunningtheLinkBudgetCalculator

MicrosoftInternetExplorerusersmayseeawarningmessagelikethis:

Note

Clicktheyellowbarandfollowtheinstructionstoallowblockedcon
tent.
TousetheLinkBudgetCalculatorforRADWIN5000HPMP:
1.ClicktheRADWIN5000tab.

Figure234:RADWIN5000HPMPLBCmainwindow
2.ChosetherequiredRADWIN5000HPMPband.

RADWIN5000HPMPUserManual

Release3.5.50

236

RunningtheLinkBudgetCalculator

Figure235:Bandselector
Forthepurposesofourexample,wewilluse5.7305.845GHzFCC/ICConnectorized.

Note

Thisreleasesupports5/10/20/40MHzChannelBandwidths
CollocatedHBSsuseRFPEsothereisnoHSSentry

3.Entertheradiodetails.
TheFademarginistheminimumrequiredforlineofsight(LOS)conditions.For
degradedlinkconditions,alargerFademarginshouldbeused.
TheEIRPisgivenindBmandWatts.
4.TheRateitemmaybeusedforcalculatingtheLinkBudgetunderbestandworst
scenarios.Inpractice,HBSsareconfiguredforAdaptiveratewhichmaynotbe
disabled.
5.Iftherequiredrangebetweenthetwolinksitesisknown,youmayenteritdirectly.
Alternatively,youmayenterthelatitudeandlongitudeofeachsiteinthelink,in
whichcasethedistancebetweenthemwillbecalculatedanddisplayed.

RADWIN5000HPMPUserManual

Release3.5.50

237

RunningtheLinkBudgetCalculator

Figure236:Calculationofdistancefromsitecoordinates
Ifforexample,weenter:
SiteA:41.1Nlat75.2WLong
SiteB:40.8Nlat75.0WLong
andpressSet,

therangewillbecalculatedanddisplayed:

RADWIN5000HPMPUserManual

Release3.5.50

238

RunningtheLinkBudgetCalculator

6.LocatedtotherightofthegreenCoordinatesbuttonisadropdownlistofClimacticC
Factorvalues.Itisonlyavailableifyouchooseanonadaptiverate.

Figure237:ClimacticCFactors
Forhelpaboutwhatthesemean,clickthe?buttontotherightofthelistin
Figure 237.

RADWIN5000HPMPUserManual

Release3.5.50

239

RunningtheLinkBudgetCalculator

Figure238:ClimacticCFactordescription
InFigure 239wedisplayamapoftheworldshowingCFactorcontours:

Figure239:WorldmapshowingCFactorcontours
7.ClickCalculatetoobtaintherequiredperformanceestimate.
Placingthecursorinanyothercalculatedfieldwillalsoupdatethe
calculatedresults.

Note

RADWIN5000HPMPUserManual

Release3.5.50

2310

RunningtheLinkBudgetCalculator

Figure2310:LBCResultssection
TheExpectedPerformanceparametersarecalculatedanddisplayed:

ExpectedRSStheexpectedRSSthattheRADWINManagershowswhentheRADWIN
5000HPMPODUsareoptimallyaligned

ServicesTypeEthernetonly
EthernetRatemaximumthroughputavailableforthechosenparametercombination
AntennaheightforLOStheminimumantennaheightrequiredforlineofsightopera
tion.Itisthesumoftheheightrequiredforboresightclearanceduetotheearthscur
vatureplustheheightrequiredtocleartheFresnelzone

Iftheexpectedperformanceisnotsuitableforyourapplication,trydifferentparametersand
repeatthecalculation.

RADWIN5000HPMPUserManual

Release3.5.50

2311

Chapter24:

SpectrumView
WhatisSpectrumView
TheRADWINManagerSpectrumViewutilityisanRFsurveytooldesignedtosupportthe
sectorinstallationpriortofullsectorserviceactivation.Thetoolprovidescomprehensiveand
clearspectralmeasurementinformationenablingeasier,fasterandbetterquality
installations.
Youcanviewrealtimespectruminformation,savethespectralinformationandview
retrievedspectralinformationfromhistoricspectrumscans.
SeparateinformationisgeneratedfortheHBSandHSUsallbyselection.Ageneralsector
levelHighestInterferenceviewisalsoprovided.
RADWINsspectrummeasurementandestimationalgorithmsaredesignedtoshowaccurate
informationaccommodatingvariationsinfrequency,temperatureandinterferencepower
andatthesametimeovercominganomaliesthattendtooccurinhighinterference
environments.

Whoneedsit
Asindicatedinthepreviousparagraph,SpectrumViewisprimarilyaprofessionaltoolforthe
technician.TheSpectrumViewreportsmaybegeneratedasimages,CSVfilesortextfilesas
partoftheGetDiagnosticsfeature.AlloftheseareintendedforusebytoRADWINCustomer
Servicetoassistwithdiagnosinginterferencerelatedproblems.

ScopeofthisChapter
Inviewofthenatureoftheintendedaudience,weassumethatthereaderknowsaboutRF
SpectrumAnalysis.Thischaptertherefore,isnotatutorialonRFSpectrumAnalysisandis
restrictedtoshowinghowtousetheSpectrumViewtoolwithoutanyfurthertheoretical
explanations.

RADWIN5000HPMPUserManual

Release3.5.50

241

TwoWaystoRunSpectrumView

TwoWaystoRunSpectrumView
SpectrumViewmayberunfromtheHBSinwhichcaseyouhaveachoiceofanalyzingallsites
inthesectorinonerun,ormakingaselection.
SpectrumViewmayalsoberunonamanagingcomputerdirectlyconnectedtoanHSU.
RememberthatinsuchacasetheresultswillbequitedifferentiftheHSUispartofasector
(registeredornot)orifitiscompletelystandalone,forexampleusingadifferentspectral
rangeandoperatingBandfromtheHBS.Intheformercase,expectanoisehumparound
thechannelsusedbythesector,duetothedutysignalsfromtheHBS.

WhereistheSpectrumViewDatastored
SpectrumViewdataisalwaysstoredintheODUoriginatingtheanalysis.TheHBSmaintains
thelastSpectrumViewanalysisdataforallmembersofthesector.IfyourunSpectrumView
fromadirectlyconnectedHSU,itstoresitsowndata,whichmaybequitedifferentfromthe
analysisobtainedforthesameHSUfromtheHBS.

SpectrumViewMainWindow:HBS
Inthissectionwereviewthemainwindowmanagementcontrols.
ClicktheSpectrumViewbutton
mode:

RADWIN5000HPMPUserManual

.TheSpectrumViewmainwindowopensinfullscreen

Release3.5.50

242

SpectrumViewMainWindow:HBS

UsethetopleftpaneltosettheSpectrumViewconfigurationparametersandchoosean
analysistypeEntireSectororSpecificHSU.

ThesettingsarestickyfortheHBSandwillbereused.Theanalysisrangeislimitedfrom
4900to6050MHzwithamaximumdifferenceof500MHz.Erroneousentrieswillbeshown
witharedborderlikethis:
Thetimeoutisthemaximumanalysistimepersite.Usethebottombuttonbartostartan
analysis,tostoparunninganalysisorrunaHighestInterferenceprofileforthesector:

IfyouchoosetoruntheanalysisforspecificHSUs,ThelefthandHSUpanelwillchange:

RADWIN5000HPMPUserManual

Release3.5.50

243

SpectrumViewMainWindow:HBS

ChecktherequiredHSUsandthenStart.
Sincealargesectorwillclutteruptherighthanddisplayarea,youmayselectivelyShow,
minimizeorremoveasectormember.Anotherwayoffreeingupmorespaceforanalysis
displaysistohidethelefthandpanelusingthecircledarrow:

IfforexampleyouclickShowontheHBS,thefollowingviewwillopenintherightpanel:

RADWIN5000HPMPUserManual

Release3.5.50

244

SpectrumViewDisplayFunctionButtons

Figure241:SpectrumViewdatapanelfortheHBS,readyfordata
ThestandardXbuttonclosesthewindowcompletely(butdoesnotloosedata).Thebutton
collapsestheviewtolooklikethis:

Thetwosidearrows(circled)areusedtoreorderastackofsuchviewonthedisplayarea:

TheremainingcontrolsontheSpectrumViewmainwindowrelatetoSpectrumViewdata
manipulation.Wewillcovertheminthenextsectionusingaliveanalysis.

SpectrumViewDisplayFunctionButtons
SpectrumViewdatamanipulationfunctionsareprovideonthetopbuttonbar:

Eachbuttonfunctionappliestoallofthesectormembersatonce.

Note

RADWIN5000HPMPUserManual

Release3.5.50

245

RunningSpectrumViewfromtheHBS

Table241:SpectrumViewAnalysisDisplayButtonsfunctionality
Butto
n

Purpose

Show/HideAntennaA

Show/HideAntennaB

Show/Hideaverage
Show/Hidecurrentchannel
(HSUsonly)
Show/Hidemaximum

Show/HideDFSinformation

Show/Hidepointvalues

SavetheanalysistoaCSVfile
Clearallsectormember
analysesfromthedisplay
(Theycanbeshownagain)

RunningSpectrumViewfromtheHBS
ChooseEntiresectorandclickStart.Youareofferedthefollowingcautionarymessage:

RADWIN5000HPMPUserManual

Release3.5.50

246

RunningSpectrumViewfromtheHBS

IfitisacceptabletodroptheserviceclickYes.Theprocessingmayappeartohavestopped
butitisnotcompleteuntilalloftheShowbuttonsforselectedHSUsareenabled.
HereistheresultfortheHBS:

Thekeystothecolorcodingispermanentlydisplayedatthebottomofthemainwindow:

Figure242:SpectrumViewAnalysiscolorcodes
ThegreenbandreflectsthecurrentHBSoperatingfrequency.Noticealsothesmallflyover
disketteicon(circled)totheupperleftofeithergraph.ClickingitopensaWindowsFileSave
dialogallowingyoutosavethegraphtodiskasajpgfile.
HereistheanalysisforoneoftheHSUs.Itisabitdifferent:

Thelightgreenrectangleinthebackgroundofbothantennadisplaysreflectsactualchannel
(20MHzwidehere)beingusedbytheHSU.ThetitlebaralsocontainstheHSUsIPaddress.
Thereisafurtherdisplayofinterest:HighestInterferenceforallHSUsinthesector:

RADWIN5000HPMPUserManual

Release3.5.50

247

RunningSpectrumViewfromaHSU

SeeFigure 242forthecolorcoding.

RunningSpectrumViewfromaHSU
ThereisnodifferenceinprinciplebetweenrunningaSpectrumViewanalysisforaHSUand
runningitforaHBS.ThereisamajordifferencebetweenrunningSpectrumViewonanactive
HSU(registeredornot)orintotalisolationfromthesector.Hereiswhathappensintotal
isolation:

Figure243:HSUspectrumanalysisincompleteisolationfromthesector
NowwereturntheHSUtothesector:

RADWIN5000HPMPUserManual

Release3.5.50

248

Zoominginandout

Figure244:HSUspectrumanalysiswithinthesector
ThehumpinFigure 244reflectsthedutycyclesignalfromtheHBScenteredonthecurrent
channel(circled).

Zoominginandout
Youmayzoominonarangeofinterestandenlargeit.Usethemousetoswipetherangefrom
lefttorightorreverseandthenclick.Theswipedrangeiszoomedin.Youmayrepeatthis
severaltimes.Thezoomappliestoallchartsforallelementintheanalysis.Anindicatoris
providedatthetoprightofeachchart:

RADWIN5000HPMPUserManual

Release3.5.50

249

Zoominginandout

ZoomOutreturnsyoutothepreviouszoomstate;Showallrevertsyoutotheoriginaldisplay.
Inazoomedstate,ahorizontalscrollbarenablesyoutoviewotherareasofthedisplayed
frequencyrange.

RADWIN5000HPMPUserManual

Release3.5.50

2410

Chapter25:

UsingtheWebInterface
WhatisitFor
TheWebInterface(WI)enablesyoutocarryoutbasicsectormanagementfunctionsusinga
Webbrowser.
Itmaybeusedto

Monitorasectoronaminimalbasis
Checksectorparametersandmakelimitedchanges
ViewthelinkInventory
InspecttheRecentEventslogs

WhoNeedsit
TheWIisatoolfortechnicianstoquickinstallaHSUinalinkwithminimumeffort.
Itmayalsobeemployedbyauserforaquicklookatcurrentoperatingparametersandthe
RecentEventslogs.

RADWIN5000HPMPUserManual

Release3.5.50

251

HowitWorks

HowitWorks
Assume the sector setup, which we used in Chapter5 and later. We repeat it here for
convenience:

Table251:PreconfiguredsetupHBS
Location

Attribute

IPv4

IPv6

Value

Address

10.104.50.200

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::200

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSinthesame
subnet

SectorID

EBGX20560334

InheritedbyallcommunicatingfixedHSUs.

NetworkID

EBX

Inheritedbyallcommunicatingnomadic

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1andv3

Contact

Bach

Optional

Name

Bach@HBS.01

LocationofContactoptional

Band

5.7305.845GHzFCC/IC

InheritedbyallcommunicatingHSUs

ChannelBandwidth

20MHz

InheritedbyallcommunicatingHSUs

UnitSerialNumber

PET540E000A00000

HBS.01

Geographiclocation
Latitude

37.8148

Longitude

144.9630

Azimuth(deg)

Beamwidth(deg)

90

Antennaheight(m)

130

UsedforinitialdefaultplacementofHSUs

RADWIN5000HPMPUserManual

Release3.5.50

FromRFplan,notused

252

HowitWorks

Table252:PreconfiguredsetupHSUs
Location

Attribute

IPv4

IPv6

Value

Address

10.104.50.1

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::1

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSin
thesamesubnet

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Haydn

Optional

Name

Haydn@HFU.01.01

LocationofContactoptional

HFU.01.01
Downlink

Uplink

TimeSlots

Mayvarywithcontext

UnitSerialNumber

P07030E000A0003E

Geographiclocation
Latitude

37.89651

Longitude

145.15716

Antennaheight(m)

10

IPv4

IPv6

Address

10.104.50.2

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::2

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

FromRFplan,notused

AllcommunicatingHSUsandHBSin
thesamesubnet

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Mozart

Optional

Name

Mozart@HFU.01.02

LocationofContactoptional

HFU.01.02
Downlink

Uplink

TimeSlots
UnitSerialNumber

Mayvarywithcontext
P07030E000A000422

Geographiclocation
Latitude

37.62400

Longitude

145.21484

Antennaheight(m)

60

RADWIN5000HPMPUserManual

Release3.5.50

FromRFplan,notused

253

HowitWorks

Table252:PreconfiguredsetupHSUs(Continued)
Location

Attribute

IPv4

IPv6

HFU.01.04
(Usedonlyto
illustrateAES
265)

Value

Address

10.104.50.4

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::4

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSin
thesamesubnet

Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Handel

Optional

Name

Handel@HFU.01.04

LocationofContactoptional

Downlink

Uplink

TimeSlots

Mayvarywithcontext

UnitSerialNumber

P07030E000A0003B

SupportsAES256

Geographiclocation
Latitude

37.4018

Longitude

145.0086

Antennaheight(m)

60

FromRFplan,notused

Table253:PreconfiguredsetupLevelallocationformaximumnomadicHSUs
Level

Numberof
nomadicHSUs

TimeSots
Downlink

Uplink

RADWIN5000HPMPUserManual

Release3.5.50

Remark
IncludesHNU.0.01below

254

WhatitProvides

Table254:Preconfigured setup - one nomadic HSU


Location

Attribute

IPv4

IPv6

Value

Address

10.104.50.3

NetMask

255.255.0.0

DefaultGateway

10.104.10.21

Address

2005:104:50::3

SubnetPrefixLength

32

DefaultGateway

2005:104:20::21

Remark

AllcommunicatingHSUsandHBSin
thesamesubnet

HNU.01.01
Protocol

SNMPv1

CanbesettoSNMPv3orbothv1

Contact

Brahms

Optional

Name

Brahms@HNU.01.01

LocationofContactoptional

Downlink

Uplink

TimeSlots
UnitSerialNumber

Mayvarywithcontext
P07030E000A0003B

Onthemanagingcomputer,pointyourbrowserto10.104.50.200andlogonasshownbelow.
YoucanalsologonovertheairtoregisteredHSUsinthesameway.
ForstandaloneorunregisteredHSUs,youmustconnectamanagingcomputerdirectlytothe
HSUandagainlogonasshownbelow.

WhatitProvides
TheWIisadevelopingtechnology.Itispossiblethatthecurrentdistributedreleasemayhave
additionalorslightlydifferentfeaturesfromthoseshownhere.Thedescriptionbelow,should
neverthelessgiveyouagoodideaofhowtousetheWI.

Prerequisites
Hardware
YouneedaregularLANconnectionbetweenamanagingcomputerandoneofthesector
ODUs.TheWIcanbeuseddirectlyoppositetheHBSanyofitsHSUs.Itcanalsobeusedover
theairfromtheHBStoanyregisteredHSU.
TheWIisavailableforRADWIN2000CandRADWIN2000BODUsatreleaselevel2.6.00or
lateralongwithRADWIN5000ODUs,fromrelease3.2.00orlater.

RADWIN5000HPMPUserManual

Release3.5.50

255

Software

Software
Yourcomputershouldhaveatleastversion6ofMSInternetExplorer.TheWebinterfacealso
workswithotherbrowserssuchasMozillaFirefoxversion3andlater.

TechnicalBackground
YoushouldbefamiliarwiththeconceptsunderlyingtheRADWINManagerandpreferably
withtheManageritself.

SpecialConsiderationsWorkingwiththeWI
AdvancedConfigurations
ForsetupconfigurationsusingfeaturessuchasHSS,VLANandQoS,youwillneedtousethe
RADWINManager.

OperationalEffects
SeveralWIfunctionscausetemporarysyncloss.Typically,changingthenumberofantennas
fallsintothiscategory.ThesecaseswillbepointedoutinWarningmessages.

SomeWorkingTips
Youcan:

LogontoaODUonthedefaultIPaddressof10.0.0.120/8,settheLinkIDandIP
addressinsteadofusingtheRADWINManagerasinChapter6.UnliketheLocalCon
nectionmethod,youneedtoresettheODUtoseethechangeintheWebInterface.
ChangetheoperatingBandofanHSUinsteadofusingtheRADWINManagerasin
Chapter8.Youcanrevertitthesamewayorbyadirectconnection,loggedonas
Installer.YoucannotchangetheoperatingBandoftheHBSinthisway.
LookatRecentEventsforeithersite

Youcannot:

ChangedefaultTxpower
ConfigureSpatialMultiplexing/Diversity
ManageotherfeaturessuchasGSU(whensupported),VLAN,QoS
PerformSoftwareupgrade

Beverycareful:

UsingthistoolifyourlinkisprovidingCustomerServicewhichmaynotbeinterrupted
withsynclosses

RADWIN5000HPMPUserManual

Release3.5.50

256

ScopeofthisChapter

ScopeofthisChapter
Theremainderofthischapterisdividedintothreesections:Loggingon,HBSConfiguration
andHSUConfiguration.

Loggingon
TousetheWebinterface,simplypointyourbrowsertotheIPaddressofthesitetowhichyou
areconnected.

Figure251:WebinterfaceLogon
TheUserNameandPasswordarerespectively,adminandnetmanasusedforTelnetaccess.
YoumustclicktheLogInbuttontoeffectentrytotheWI.Theforegoingappliestoboththe
HBSandtheHSUs.

RADWIN5000HPMPUserManual

Release3.5.50

257

HBSManagement

HBSManagement
TheMainWindow

Figure252:WebinterfaceMainwindow,HBS
TheSectorID(EBGX20560334)appearsallorinpartastheheading.TheHBSInfopanelisself
explanatory.ThegreenActiveindicatorwillvaryaccordingtothestatusoftheHSUshownby
theRADWINManager.

Figure253:SectorStatuspanel
(itwilltypicallybeActive,Inactive,Probingetc.)
ThebottompanelshowsallmemberHSUs.ThegreenLEDiconswillchangecolortoreflect
thestatusofHSUs.Forexample,deregisteringanHSUwillchangeittoblackasinthe
RADWINManager.

RADWIN5000HPMPUserManual

Release3.5.50

258

Configure

Figure254:HSUHaydnderegistered
Now,clickanywhereontheHBSInfopanel:

Configure
TheConfigurebuttonopensthefollowingdisplay:

RADWIN5000HPMPUserManual

Release3.5.50

259

Configure

System
TheName,ContactandLocationfieldmaybechanged.ClickingSavecommitsthem.Clicking
RefreshrevertsthefieldstotheirlastSavedvalues.

AirInterface
Thereisnothingthatcanbechangedonthispanel.ClickingtheAntenna&TxPowerbutton
opensupthefollowingwindow:

TheonlyitemthatcanbechangedistheAntennaType:

RADWIN5000HPMPUserManual

Release3.5.50

2510

Configure

ChangingAntennaTypewillcallasectorwidesyncloss.

Caution
Inventory
TheInventorydisplayisforinformationonly.

Management
TheManagementfieldsareallfullyeditable:

RADWIN5000HPMPUserManual

Release3.5.50

2511

Configure

Ifyouchangeanyofthesefields,youwillcauseaHBSreset:

RADWIN5000HPMPUserManual

Release3.5.50

2512

Configure

Other
YoumaychangetheHBSLANportconfiguration:

Youwillreceivethefollowingnotification:

Thisactionofcourse,hasnobearingonthesector.

RADWIN5000HPMPUserManual

Release3.5.50

2513

Events

Events
TheRecentEventListisdisplayed:

Reset
UsethisbuttontoresettheHBS.

HSUManagement
HSUmanagementfollowsthesamepatternasthatfortheHBS.Toavoidtediousrepetition,
Wewillonlypointoutsignificantdifferences.

TheMainWindow
HSUconfigurationisaccomplishedbyclickingtherequiredHSUinthebottompanelof
Chapter25.Forthepurposesofthissection,wehavederegisteredHaydnsothepanellooks
likethis:

ClickMozart.Hereiswhatyousee:

RADWIN5000HPMPUserManual

Release3.5.50

2514

TheMainWindow

ClickingConfigure,opensupanewtabinyoubrowser,pointingtoMozart:

HereistheHSUmainwindow:

RADWIN5000HPMPUserManual

Release3.5.50

2515

TheMainWindow

TheonlyitemhererequiringcommentistheConfigurebutton.Installisdisabledandthe
remainingthreebuttonsarethesameasfortheHBS.
HereistheConfiguredisplay:

Theonlyfunctionhere,whichdiffersfromthecorrespondingHBSfunction,istheAir
Interfacetab.

RADWIN5000HPMPUserManual

Release3.5.50

2516

TheMainWindow

InadditiontotheAntenna&TxPowerbutton,youmayalsochangeoperatingBand:

RADWIN5000HPMPUserManual

Release3.5.50

2517

TheMainWindow

Warning

Therearetwostrictcaveatstousingthisfunction:
Itisintendedasatoolforthefieldtechnician,replacinganHSUinthe
field.
IfyouchangetheoperatingBandofaregisteredHSU,youwillloose
itfromthesector.TheonlyremedyistologontotheHSUwitha
directconnectionandeitherreversetheaboveprocess,orlogonas
InstallerandusingtheregularChangeBand.

RADWIN5000HPMPUserManual

Release3.5.50

2518

WEBInterfaceforVMUs

WEBInterfaceforVMUs
TheVMUhasGPSsupportthatisreflectedinitsWIpage:

NoticethecurrentpositionoftheVMUinthelowerpartofthepanel.UsingtheMapView
tabopensaGoogleEarthpicturecenteredonthecurrentlocation:

RADWIN5000HPMPUserManual

Release3.5.50

2519

WEBInterfaceforVMUs

Thecurrentpositionismarkedwiththe

RADWIN5000HPMPUserManual

icon.

Release3.5.50

2520

Part7:ProductReference

Release3.5.50

AppendixA:

TechnicalSpecifications
ScopeoftheseSpecifications
Thisappendixcontainstechnicalspecificationsforthemajorlinkcomponentsappearingin
thisUserManual.Theyarecorrectatthedateofpublication,butareintendedforgeneral
backgroundonly.Thelatestauthoritativeandmostuptodatetechnicalspecificationsare
availableasDataSheetsobtainablefromRADWINCustomerService.
Inanyevent,RADWINreservestherighttochangethesespecificationswithoutnotice.

ODUHBSandHSU/HMU
Configuration
Architecture

ODUtoPoEInterface

ODU:OutdoorUnitwithIntegratedAntenna,
ConnectorizedforExternalAntennaorEmbedded
UsesRADWINPoEtypedeviceforEthernetonly
HBS:
OutdoorRADWINCAT5ecable.maximumcable
length:100mfor10/100BaseT.
OutdoorRADWINCAT5ecable.maximumcable
length:75mfor1000BaseT.
HSU:
OutdoorCAT5ecable;maximumcablelength:100m(10/
100BaseT)

Radio
Capacity

HSUsupport
Coverage

HBS:Upto250Mbpsaggregatenetthroughput
dependingonmodelandregulation
HSU:Upto50Mbpsaggregatenetthroughputdepending
onmodelandregulation
Upto32HSUsperHBS(varieswithHBSmodel)
Upto40km/25miles

RADWIN5000HPMPUserManual

Release3.5.50

A1

ODUHBSandHSU/HMU

RadioModulation
AdaptiveModulation&Coding
AutomaticChannelSelection
DFS
Diversity
SpectrumView
QoS
VLAN
TDDIntrasiteSynchronization
TDDInterSiteSynchronization
DuplexTechnology
ErrorCorrection

2x2MIMOOFDM(BPSK/QPSK/16QAM/64QAM)
Supported
Supported
Supported
Supported
Supported
Supported Packetclassificationto4queuesaccordingto
802.1pandDiffserv
Supported802.1Q,802.1P,QinQ
SupportedusingHSS
SupportedthroughcommonGPSreceiverpersite
TDD
FECk=1/2,2/3,3/4,5/6

RateDualAntenna[Mbps]at20
13
MHzCBW
RateSingleAntenna[Mbps]at
6.5
10MHzCBW
Modulation
BPSK

26

39

52

78

104

117

130

13

19.5

26

39

52

58.5

65

QPSK
1/2
3/4

16QAM
1/2
3/4

64QAM
2/3
3/4
5/6

FEC[k=]
1/2
MaxTxPower[dBm]for4.86
25
24
21
19
18
GHz
Sensitivity(dBm)@BER<10e9at
20MHzCBW
88
86
83
81
77
72
70
67
For10MHzCBW,deduct3dBm
Encryption
AES128;AES256availablebyupgradelicense.

RADWIN5000HPMPUserManual

Release3.5.50

A2

ODUHBSandHSU/HMU

SupportedBands
ThebandsshownbelowaresupportedbyRADWINproducts.Boththebandsandrelated
ChannelBandwidthsareproductdependent.
Band
(GHz)

Occupied
CBW
Regulation FrequencyRange
DFS?
(MHz)
(GHz)

2.3

Universal

2.4

FCC/IC

2.4

ETSI

2.5

FCCBRS

3.4

ETSI

3.5

ETSI

3.6

ETSI

IC

3.5

Universal

FCC/IC

2.30452.4745
2.3022.477
2.2972.482
2.2872.492
2.40952.4645
2.4072.467
2.4022.472
2.3922.482
2.40952.4745
2.4072.477
2.4022.482
2.3922.492
2.49652.6925
2.4942.695
2.4892.700
3.41053.4825
3.4083.485
3.4033.490
3.47753.6025
3.4753.605
3.4703.610
3.59753.7025
3.5953.705
3.5903.710
3.47553.6495
3.4733.652
3.4683.657
3.29753.8025
3.2953.805
3.2903.810
3.65053.6745
3.6503.675
3.6503.675

RADWIN5000HPMPUserManual

5
10
20
40
5
10
20
40
5
10
20
40
5
10
20
5
10
20
5
10
20
5
10
20
5
10
20
5
10
20
5
10
20

Compliance(Notes)

No

N/A(SupportedCBWproductdependent)

No

FCC47CFR,Part15,SubpartCandICRSS
210

No

ETSIEN300328(SupportedCBWproduct
dependent)

No

FCC47CFR,Part27,SubpartM(BRS/EBS)

No

ETSIEN3023262(Nominally,3.5GHz
ETSI)

No

ICRSS192

No

N/A

No

FCCPart90SubpartZandICRSS197
(Restricted)

Release3.5.50

A3

ODUHBSandHSU/HMU

Band
(GHz)

Occupied
CBW
Regulation FrequencyRange
DFS?
(MHz)
(GHz)

4.4

Universal

4.8

Universal

FCC/IC
4.9
Universal

5.0

Universal

ETSI
5.1
Universal

5.2

FCC/IC

4.39755.0025
4.3955.005
4.3905.010
4.80754.9025
4.8054.905
4.8004.910
4.7904.920
4.94254.9875
4.9404.990
4.9404.990
4.89755.0025
4.8955.005
4.8905.010
4.8805.020
4.99755.1525
4.9955.155
4.9905.160
4.9805.170
5.1505.350
5.1505.350
5.14755.3375
5.1455.340
5.1405.345
5.1305.355
5.25255.3475
5.2555.345
5.2555.345
5.2555.345

RADWIN5000HPMPUserManual

5
10
20
5
10
20
40
5
10
20
5
10
20
40
5
10
20
40
10
20
5
10
20
40
5
10
20
40

Compliance(Notes)

No

N/A

No

N/A

No

FCC47CFR,Part90,SubpartYandICRSS
111

No

N/A

No

N/A

Yes

ETSIEN301893

No

N/A

Yes

FCC47CFR,Part15,SubpartEandICRSS
210

Release3.5.50

A4

ODUHBSandHSU/HMU

Band
(GHz)

Occupied
CBW
Regulation FrequencyRange
DFS?
(MHz)
(GHz)
ETSI

FCC/IC

5.4
Universal

IC

ETSI

FCC/IC

5.8
MIIChina

WPCIndia

5.9

Universal

6.0

Universal

5.4755.720
5.4755.720
5.4755.720
5.47755.7175
5.4805.715
5.4805.715
5.4805.715
5.47255.7225
5.4705.725
5.4655.730
5.4555.740
5.47755.7175
5.4805.715
5.4805.715
5.4805.715
5.7255.875
5.7255.875
5.72755.8475
5.7255.850
5.7255.850
5.7255.850
5.73755.8375
5.7355.840
5.7305.845
5.7205.855
5.83255.8675
5.8305.870
5.8255.875
5.8155.885
5.72755.9525
5.7255.955
5.7205.960
5.7105.970
5.69756.0525
5.6956.055
5.6906.060
5.6806.070

RADWIN5000HPMPUserManual

10
20
40
5
10
20
40
5
10
20
40
5
10
20
40
10
20
5
10
20
40
5
10
20
40
5
10
20
40
5
10
20
40
5
10
20
40

Compliance(Notes)

Yes

ETSIEN301893

Yes

FCC47CFR,Part15,SubpartEandICRSS
210

No

N/A

Yes

ICRSS210

Yes

ETSIEN302502

No

FCC47CFR,Part15,SubpartCandICRSS
210

No

MIIChina(SupportedCBWproduct
dependent)

No

GSR38(SupportedCBWproduct
dependent)

No

N/A

No

N/A

Release3.5.50

A5

ODUHBSandHSU/HMU

Occupied
CBW
Regulation FrequencyRange
DFS?
(MHz)
(GHz)

Band
(GHz)

5/10/
No
20
10
No
20
5/10/
No
20/40

5.9286.400

ETSI

5.8956.4050
5.8906.410

6.4
Universal

5.7256.400

Compliance(Notes)

Lowtemperature,to35C
N/A
N/ALowtemperature,to55C

ThefollowingMaxTxPowerlimitationsapplytoallproductssupportingthe3.5GHzETSI
band:
OccupiedSub
Band
GHz

Center
Frequency
GHz

3.4033.490

3.4133.480

3.4703.610

3.4803.600

3.5903.710

3.6003.700

Note

Mode

Channel
Bandwidth
MHz

MaxTx
Power
dBm

Frequency
Step
KHz

17
Inactive

5,10,20

23()

250

25()

()The3.480GHzfrequencyisoverlapped,occurringintwodierentbands
asshown.Ifyouwishtousethe3.480GHzfrequency,youshouldsetMax
TXPowerto17dBm.
()The3.600GHzfrequencyisoverlapped,occurringintwodierentbands
asshown.Ifyouwishtousethe3.600GHzfrequency,youshouldsetMax
TXPowerto23dBm.

Management
ManagementApplication(per
sector)

RADWINManager

Protocol

SNMPandTelnet

NMS

RADWINNMSRNMS

Environmental
OperatingTemperatures

HBS/HSU:35Cto+60C/31Fto+140F

Humidity

HBS/HSU:Upto100%noncondensing,IP67

Storage

40to85C/40Fto185F

RADWIN5000HPMPUserManual

Release3.5.50

A6

HSUwithACPowerFeeding

Mechanical
HBSwithIntegratedAntenna
HBS/HSUConnectorized
HSUSFFwithEmbeddedantenna)
RADWIN5505HSUConnectorized

37.1/14.84(W)x37.1/14.84(H)x9.00/3.6(D)cm/in;3.5kg
/7lbs
19.5/7.7(W)x27.0/10.8(H)x5.5/2.2(D)cm/in;1.8kg/3.6
lbs
19.5/7.7(W)x27.0/10.8(H)x7/2.8(D)cm/in;1.8kg/3.6
lbs
19.5/7.7(W)x27.0/10.8(H)x5.5/2.2(D)cm/in;1.1kg/2.4
lbs

RADWIN5505HSUwithIntegrated
24.1/9.4(W)x19.7/7.7(H)x7.7/3(D)cm/in;1.3kg/2.8lbs
Antenna,alsoHSUAC

Power
PowerFeeding

PowerprovidedoverODUIDUcableusingPoE

PowerConsumptionalone

HBS:<25W,HSU:<20W,HSU505/510/525<10W

Safety
TUV
ETSI/IEC

UL609501,UL6095022,CAN/CSAC22.2609501,CAN/
CSAC22.26095022
EN/IEC609501,EN/IEC6095022

EMC
FCC

47CFRClassB,Part15,SubpartB

ETSI

EN300386,EN3014891,EN3014894

CAN/CSACEI/IEC

CISPR22ClassB

AS/NZS

CISPR22ClassB

HSUwithACPowerFeeding
Configuration
Architecture
ODUtoLANandPoEInterface

ODU:OutdoorUnitwithIntegratedAntenna
OutdoorRADWINCAT5ecable.Maximumcablelength:
100mfor10/100BaseT.

Radio
Capacity

10Mbpsnetaggregatethroughput

Range

Upto40km/25miles

ChannelBandwidth

Configurable:5,10,20and40MHz

Modulation

2x2MIMOOFDM(BPSK/QPSK/16QAM/64QAM)

RADWIN5000HPMPUserManual

Release3.5.50

A7

HSUwithACPowerFeeding

BandwidthAllocation

SymmetricandAsymmetric

DFS

Supported

AdaptiveModulation&Coding

Supported

AutomaticChannelSelection

Supported

Diversity

Supported

SpectrumViewer

Supported

MaxTxPower

25dBm

DuplexTechnology

TDD

ErrorCorrection

FECk=1/2,2/3,3/4,5/6

Encryption

AES128

EthernetInterface

10/100BaseT

PoEport

10/100BaseT,IEEE802.3af

Layer2

HubMode
Packetclassificationto4queuesaccordingto802.1pand
Diffserv,Dynamicschedulingaccordingtoairinterface
changes

QoS
VLAN

Supported802.1Q,8021.P,QinQ

Mechanical
Dimensions

24.1(w)x19.7(h)x7.7(d)cm

Weight

1.3kg/2.8lbs
19.7/7.7(W)x24.1/9.5(H)x9.0/3.6(D)cm/in;1.3kg/2.8
lbs

IntegratedAntenna

Power
PowerFeeding

DirectACpowerfeeding85265VAC

PowerConsumptionalone

<10W

Environmental
OperatingTemperatures
Humidity

35Cto+60C/31Fto+140F
100%condensing,IP67(totallyprotectedagainstdustand
againstimmersionupto1m)

Safety
TUV
ETSI/IEC

RADWIN5000HPMPUserManual

UL609501,UL6095022,CAN/CSAC22.2609501,CAN/
CSAC22.26095022
EN/IEC609501,EN/IEC6095022

Release3.5.50

A8

VMU

EMC
FCC

47CFRPart15,SubpartB,ClassB

ETSI

EN300386,EN3014891,EN3014894

CAN/CSA

CISPR22ClassB

AS/NZS

CISPR22ClassB

VMU
Configuration
Architecture

OutdoorUnitconnectorizedforexternalantennas

MobileBackhaulRadio
Capacity
Range
ChannelBandwidth
Modulation
ErrorCorrection
Bandwidthallocation
AdaptiveModulation&Coding
AutomaticChannelSelection
Diversity
SpectrumViewer
MaxTxPower
DuplexTechnology
Encryption

Upto50Mbpsnetaggregatethroughput(Actual
throughputdependsonrangeandspeedofthevehicle)
Upto10km/6.2miles
Configurable:5,10,20or40MHz
2x2MIMOOFDM(BPSK/QPSK/16QAM/64QAM)
FECk=1/2,2/3,3/4,5/6
Configurable:SymmetricorAsymmetric
Supported
Supported
Supported
Supported
25dBm
TDD
AES128;FIPS197

WiFiAccessPointRadio
FrequencyBand
Modulation
ChannelBandwidth
MaxTxPower
Encryption
VirtualAP
ConcurrentClients
FrequencyBand

2.4GHz;IEEE802.11b/g/n
2x2MIMOOFDM(BPSK/QPSK/16QAM/64QAM)
Configurable:20or40MHz
26dBm
WEP,WPAPSK,WPATKIP,WPA2AES,RADIUS
Upto8BSSIDs
Upto256
2.4GHz;IEEE802.11b/g/n

GPS
Type

AutonomousGPSwith1externalantenna,supporting
NMEA,TAIP

RADWIN5000HPMPUserManual

Release3.5.50

A9

VMU

Interfaces
LAN
POEout
Alarms

Autosensing10/100BaseT;M12Connector
Autosensing10/100BaseT+PoEout802.3af;M12
Connector
2alarminput;2relayoutput;M12Connector

Networking
Layer2
QoS
VLAN

BridgeMode
Packetclassificationto4priorityqueuesaccordingto
802.1porDiffserv
802.1Q,802.1P,QinQ,4094VLANS

Management
ManagementApplication
Protocol
NMSApplication

RADWINManagerorWebbasedmanagement
SNMPv1,SNMPv3,Telnet,HTTP,HTTPS
RADWINNetworkManagementSystem(RNMS)

Electrical
VoltageInputRange
PowerDissipation
PowerIgnitionControl

28VDC(1036V)6A
<25Watt(max)
Detectsignitionon/offstatusanddelayspoweroff
automatically

RADWIN5000HPMPUserManual

Release3.5.50

A10

IDUH(AggregationUnit)

SupportedBands
OccupiedFrequencyRangeatGivenChannelBandwidth
(GHz)

Band

5MHz

10MHz

20MHz

Radio
Compliance

40MHz

5.8GHzFCC/IC
(default)

5.72755.8475 5.7255.850

5.7255.850

5.7255.850

FCC47CFR,Part
15,SubpartC
andICRSS210

5.8GHzMII

5.73755.8375 5.7355.840

5.7305.845

5.7205.855

MIIfor5.8GHz

5.8GHzWPC
India

5.82755.8725 5.8255.875

5.8255.875

5.8255.875

WPCGSR38

5.4GHzFCC

5.47755.7175 5.4805.715

5.4805.715

5.4805.715

FCC47CFR,Part
15,SubpartE

5.4GHzIC

5.47755.7175 5.4805.715

5.4805.715

5.4805.715

ICRSS210

5.3GHzFCC/IC

5.25255.3475 5.2555.345

5.2555.345

5.2555.345

FCC47CFR,Part
15,SubpartE
andICRSS210

4.9GHzFCC/IC

4.94254.9875 4.9404.990

4.9404.990

N/A

FCC47CFR,Part
90,SubpartY
andICRSS111

5.9GHzUniversal 5.72755.9525 5.7255.955

5.7205.960

5.7105.970

Universal

5.4GHzUniversal 5.47255.7225 5.4705.725

5.4655.730

5.4555.740

Universal

5.3GHzUniversal 5.14755.3375 5.1455.340

5.1405.345

5.1305.355

Universal

5.0GHzUniversal 4.99755.1525 4.9955.155

4.9905.160

4.9805.170

Universal

4.9GHzUniversal 4.89754.9925 4.8954.995

4.8905.000

4.8805.00GHz Universal

IDUH(AggregationUnit)
EthernetInterface

LANInterfaceFraming/Coding

6xlegacymodePoEports(10/100/1000Mbps),upto
25Wperport
2xRJ45PHYportsof10/100/1000MbpsBasedT
Ethernet
IEEE802.3/U

LANInterfaceLineImpedance

100

PoEInterfaces
EthernetPorts

RADWIN5000HPMPUserManual

Release3.5.50

A11

IDUH(AggregationUnit)

LANInterfaceEthernetMode

Autonegotiation10/100/1000

SFPInterfaces

2xSFPportsof1000Mbps(standardMSA)

MACAddressEntries

Upto1KMACAddressentries

MaximalFrameSize

2048bytes

EthernetLatency

3ms

Mechanical
Dimensions

1U19Rackmounted,halfwidth

Weight

0.8Kg

Power
InternalPowerConsumption
PowerFeeding
Grounding
Protection

<15W@MaximalPowerfeeding
44VDC56VDC,Dualredundantinputs.3pinfemaleDC
connector
Frontpanelgroundinglug
DCinputLine&ReversePolarityprotection
PoEPortsover/underCurrent&over/underVoltage
protections

Environmental
OperatingTemperatures

40Cto55C/40Fto131F

Humidity

90%noncondensing

Storage

40to70C/40Fto158FHumidity95%

Safety
TUV

UL609501,CAN/CSAC22.2No.609501

ETSI/IEC

EN/IEC609501

EMC
FCC

47CFRPart15,SubpartB,ClassB

ETSI

EN300386;3014894;3014891

CAN/CSAAS/NZS

CISPR22ClassB

RADWIN5000HPMPUserManual

Release3.5.50

A12

GbEPoEDeviceIndoor,AC

GbEPoEDeviceIndoor,AC
Electrical
ACInputVoltage

100240VACnominal,90264VACmaxrange

InputFrequency

StandbyPower

4763Hz
2.0A(rms)115VACatMax.load
1.2A(rms)230VACatMax.load
30Afor115VACatMax.load
60Afor230VACatMax.load
0.5W(Max)at240Vac

DCOutputVoltage

56VDC

InputCurrent
Max.InrushCurrent

Protection
Indication

Shortcircuitprotection
Autorecovery
Overvoltageprotection

Greenledfornormaloperation

Interfaces

Ethernetinput

RJ45connector
OutdoorCAT5e;Maximumcablelength:75mfor
1000BaseTor100mfor10/100BaseT.
RJ45connector

ACinputondevice

StandardsocketIEC320C14type

ACcable

VarietyofACplugsavailable(seebelow)

Ethernet/ODU

RADWINRJ45connector

EthernetLANinterfacetype

RJ-45, 10/100/1000BaseT Interface (Line


Impedance -100)

PoEoutput
PoEtoODUInterface

Mechanical
Case

Plastic

Dimensions

16cm(W)x6.3cm(D)x3.33cm(H)

Weight

250g

Environmental
OperatingTemperatures

0Cto40C/32Fto104F

Humidity

90%noncondensing

RADWIN5000HPMPUserManual

Release3.5.50

A13

PoEDeviceOutdoor,DC

Safety
ULCSA

609501,C22.2No.609501

ETSI/IEC

IEC/EN609501

EMC
ESD

61000-42

RS

61000-43

EFT

61000-44

Surge

61000-45

CS

61000-46

DIPS

61000-411
FCCpart15classB,CISPRPub22classB,AS/NZSCISPR22
classB

EMI

PoEDeviceOutdoor,DC
Electrical
Inputvoltagerange

20to60VDC(singleinput)

Outputvoltage

48VDC/0.6A

PowerConsumption

0.5W(notincludingradio)

Protections

Differential15KW
Common3KW

Interfaces
EthernetLANinterfacetype

RJ45,10/100BaseTInterface(LineImpedance100W)

DCinput

2pinsconnector

ODU(PoEPort)

RJ45

Mechanical
Enclosure

Allweathercases

Dimensions

24.5cm(H)x13.5cm(W)x4.0cm(D)

Weight

1.0kg/2.2lbs

Environmental
OperatingTemperatures

RADWIN5000HPMPUserManual

35Cto60C/31Fto140F

Release3.5.50

A14

GSU

Humidity
Standards

Upto100%noncondensing
IEC6072134Class4M5
IP67

Safety
FCC/IEC/CAN/CSA

Designedtomeet609501,6095022

EMC
ETSI

DesignedtomeetEN300386;EN3014891

FCC

Designedtomeet47CFRPart15,SubpartB,ClassB

CAN/CSA

DesignedtomeetICES003ClassB

AS/NZS

DesignedtomeetCISPR22classB

GSU
Configuration
Architecture

OutdoorSynchronizationUnit;includingExternalGPS
AntennaandRFcable.(PoEdeviceshouldbeordered
separately)

GSUtoPoEInterface

OutdoorCAT5ecable;maximumcablelength:100m

Mechanical
Dimensions

21(w)x17(h)x7(d)cm

Weight

1.2kg/2.65lbs

Power
PowerFeeding

PowerprovidedbyPoEdevice

MaxPowerDissipation

<10Watt

Environmental
OperatingTemperatureRange
Humidity

40Cto60C/40Fto140F(Upto70C/158Ffor
limitedtimeorunderforcedconvection)
Upto100%noncondensing,IP67(totallyprotected
againstdustandagainstimmersionupto1m)

Safety
FCC/IC(cTUVus)
ETSI

RADWIN5000HPMPUserManual

UL609501,UL6095022,CAN/CSAC22.2609501,CAN/
CSAC22.26095022
EN/IEC609501,EN/IEC6095022
Release3.5.50

A15

LightningProtector

EMC
FCC

CFR47ClassB,Part15,SubpartB

ETSI

EN300386,EN3014891,EN3014894

CAN/CSACEI/IEC

CISPR2204ClassB

AS/NZS

CISPR222004ClassB

LightningProtector
Electrical
CompatibleInterfaces

10/100/1000BaseT

DataRates

Upto1000Mbps

NominalOperationalVoltage

48VDC

MaximumOperationalVoltage

60VDC650mA

MaximumContinuouscurrent

1A

Impedance

90to110Ohm

Connectiontype

RJ45CAT5eSTP(shielded)

Pin-out

8wires+shielding

PinsProtected

Allpinsprotected

Responsetime

<5microseconds(withODU)

Nominaldischargecurrents
LinetoLine

500A@8/20s

LinetoGround

2000A@8/20s

ImpulseDischargeCurrent
20000A,8/20s

1operationminimum

10000A,8/20s

>10operations

2000A,10/350s

1operation

200A,10/1000s

>300operations

200A,10/700s

>500operations

ImpulseSparkover
DCSpark-over20%@100V/s

150V

100V/s

350V

1000V/s

500V

RADWIN5000HPMPUserManual

Release3.5.50

A16

FastEthernetCAT5ecablerepeater

Capacitance

<2pF

DCHoldoverVoltage

80V

Mechanical
Enclosure

Metal

ConnectiontobondingNetwork

Screw

Dimensions

150mm

Weight

220gram(0.22Kg)

Environmental
Operatingtemperature

40Cto60C

Storagetemperature

50Cto70C

Enclosurerating

IP67

Humidity

100%noncondensing

FastEthernetCAT5ecablerepeater
Electrical
CompatibleInterfaces

100BaseT

DataRates

Upto1000Mbps

NominalOperationalVoltage

48VDC

MaximumOperationalVoltage

60VDC650mA

Currentconsumption

0.5A

Impedance

90to110Ohm

Connectiontype

RJ45CAT5eSTP(shielded)

Pin-out

8wires+shielding

Mechanical
Enclosure

Metal

ConnectiontobondingNetwork

Screw

Dimensions

150mm

Weight

220gram(0.22Kg)

RADWIN5000HPMPUserManual

Release3.5.50

A17

AntennaCharacteristics

Environmental
Operatingtemperature

40Cto60C

Storagetemperature

50Cto70C

Enclosurerating

IP67

Humidity

100%noncondensing

Safety
TUV
ETSI/IEC

UL609501,UL6095022,CAN/CSAC22.2609501,CAN/
CSAC22.26095022
EN/IEC609501,EN/IEC6095022

EMC
FCC

CFR47ClassB,Part15,SubpartB

ETSI

EN300386,EN3014894,EN3014891

CAN/CSAAS/NZS

CISPR22ClassB

AntennaCharacteristics
Anantennaistheradiatingandreceivingelementfromwhichtheradiosignal,intheformof
RFpower,isradiatedtoitssurroundingsandviceversa.Thetransmissionrangeisafunction
oftheantennagainandtransmittingpower.Thesefactorsarelimitedbycountryregulations.
TheRADWIN5000HPMPmaybeoperatedwithanintegratedantennaattachedtotheODU
unit,orwithanexternalantennawiredtotheODUviaNtypeconnectors.Allcablesand
connectionsmustbeconnectedcorrectlytoreducelosses.Therequiredantennaimpedance
is50.

RADWIN5000HPMPUserManual

Release3.5.50

A18

AppendixB:

WiringSpecifications
ODUPoECable(HBSandHSU)
TheODUPoEcableisshielded/outdoorclassCAT5e,4twistedpair24AWGterminatedwith
RJ45connectorsonbothends.AcableglandontheODUsideprovideshermeticsealing.
Thefollowingtableshowstheconnectorpinout:
TableB1:ODUPoERJ45ConnectorPinout
Function

Color

PoE

ODU

RxN

White/Green

RxT

Green

TxT

White/Orange

TxN

Orange

Power(+)

Blue

Power(+)

White/Blue

Power()

White/Brown

Power()

Brown

TableB2:LANGbEPoERJ45ConnectorPinout
Function

Color

PoE

LAN

TxRxA

White/Green

TxRxA

Green

TxRxB

White/Orange

TxRxB

Orange

TxRxC&Power(+)

Blue

RADWIN5000HPMPUserManual

Release3.5.50

B1

HBS/HSSUnitConnectionPinout

TableB2:LANGbEPoERJ45ConnectorPinout(Continued)
Function

Color

PoE

LAN

TxRxC&Power(+)

White/Blue

TxRxD&Power()

White/Brown

TxRxD&Power()

Brown

HBS/HSSUnitConnectionPinout
TableB3:HBS/HSSUnitConnectionPinout
Color

ODU
RJ45

HSSUNIT
RJ45

White/Green

Green
White/Orange

Notconnected

Orange

Blue

White/Blue

White/Brown

Brown

RADWIN5000HPMPUserManual

Release3.5.50

B2

UserPortConnectors

UserPortConnectors
LANPort
TheLAN10/100BaseTinterfaceterminatesinan8pinRJ45connector,wiredinaccordance
toTable B4.
TableB4:FastEthernetConnectorPinout
Function

Signal

Pin

TransmitData(positive)

TD(+)

TransmitData(negative)

TD()

ReceiveData(positive)

RD(+)

ReceiveData(negative)

RD()

DCPowerTerminals
DCPoE
TableB5:TerminalBlock2pin48VDC
Function

Pin

Right

Left

SU2ACPowerTerminal
TheSU2ACpowerportisafourpinmalesocketwithpinassignmentsasfollows:
TableB6:SU2ACpowerpinassignments
Pin

WireColor

Function

Red

Line

Notused

Black

Neutral

GreenorGreen
Yellow

Ground

RADWIN5000HPMPUserManual

Release3.5.50

B3

VMUConnectors

VMUConnectors
PowerConnector
Allwiringshouldbeatleast20AWG.
TableB7:Powerconnectorfrontviewandpinout
Connector

Function

WireColor

Pin

VMINU

Black

VPLUS

Red

VPLUS

Red

VMINU

Black

IGNITION

Yellow

LANandPoEConnectors
TableB8:LANPoEM12ConnectorPinout
Connector

Function

Color

MJ12

CAT5e

Tx+

White/Green

Tx

Green

Rx+

White/Orange

Rx

Orange

RTN

White/Brown

Brown

White/Blue

Blue

RADWIN5000HPMPUserManual

Release3.5.50

B4

DryContactAlarmConnector

DryContactAlarmConnector
TableB9:AlarmConnectorPinout
Connector

Function

Color

MJ12

ALRM_NO_OUT2

White/Green

ALRM_NO_OUT1

Green

ALRM_IN_COMMON

White/Orange

ALRM_IN1

Orange

ALRM_NC_OUT2

White/Brown

ALRM_NC_OUT1

Brown

ALRM_OUT_COMMON

White/Blue

ALRM_IN2

Blue

RADWIN5000HPMPUserManual

Release3.5.50

B5

AppendixC:

MIBReference
Introduction
AbouttheMIB
TheRADWINMIBisasetofAPIsthatenablesexternalapplicationstocontrolRADWIN
equipment.
TheMIBisdividedintopublicandaprivateAPIgroups:

Public:RFC1213(MIBII)variables,RFC1214(MIBII)SystemandInterfacessections
Private:ControlledbyRADWINandsupplementsthepublicgroup.

ThisappendixdescribesthepublicandprivateMIBusedbyRADWIN.

Terminology
Thefollowingtermsareusedinthisappendix.
Term

Meaning

MIB

ManagementInformationBase

API

ApplicationProgrammingInterface

SNMP

SimpleNetworkManagementProtocol

Inaddition,theMIBusesinternally,theoldernotionsofLocalsiteandRemotesitewhere
thismanualwouldusesiteAandsiteB.
Toavoidburdeningthereader,thisappendixwillfollowtheMIBusage.

RADWIN5000HPMPUserManual

Release3.5.50

C1

InterfaceAPI

InterfaceAPI
ControlMethod
TheRADWINManagerapplicationprovidesallthemeanstoconfigureandmonitora
RADWIN5000HPMPlink,communicatingwiththeSNMPagentineachODU.EachSNMP
agentcontainsdataoneachofthePoEsandODUsinthelink.Bothagentscommunicatewith
eachotherovertheairusingaproprietaryprotocol.

EachODUhasasingleMACaddressandasingleIPaddress.

Note
TocontrolandconfigurethedeviceusingtheMIB,youshouldadheretothefollowingrules:

Theconnectionforcontrolandconfigurationistothelocalsite,overanySNMP/UDP/IP
network.
AllParametersshouldbeconsistentbetweenbothoftheODUs.Notethatinconsistency
ofairparameterscanbreaktheairconnection.Tocorrectairparametersinconsistency
youmustreconfigureeachoftheODUs.
Commonpracticeistoconfiguretheremotesitefirstandthentoconfigurethelocal
site.
Forsomeoftheconfigurationparametersadditionalactionmustbetakenbeforethe
newvalueisloaded.Pleaserefertotheoperationintheparametersdescription.
SomeoftheMIBparametersvaluesareproductdependent.Itisstronglyrecommend
usingtheRADWINManagerApplicationforchangingthesevalues.Settingwrongvalues
maycauseindeterminateresults.

CommunityString
Tocontrolalink,allSNMPrequestsshouldgotothelocalsiteIPaddress.
SeeTable 56fordefaultCommunitystrings.

PrivateMIBStructure
ThesectionsintheprivateRADWINMIBanditslocationintheMIBtreeareshownin
Figure C1below:

RADWIN5000HPMPUserManual

Release3.5.50

C2

MIBParameters

FigureC1:TopLevelSectionsoftheprivateMIB
TheproductsMIBsectioncontainsthedefinitionoftheObjectIDsforthetwoformfactorsof
theODUs,IntegratedAntennaandConnectorized(referredintheMIBasexternalantenna)
andGSU(whereapplicable):

FigureC2:ProductMIB
TheGpsSynchronizerFamilyMIBdefinestheGSU.
ThegeneralMIBincludeasinglegenericparameterthatisusedbyalltrapsasatrap
descriptionparameter.

MIBParameters
ThefollowingsectiondescribesalloftheMIBparameters.TheMIBparametersfollowthe
followingnamingconvention:
RADWIN5000HPMPUserManual

Release3.5.50

C3

MIBParameters

<winlink1000><Section1>...<Sectionn><ParameterName>

Foreachoftheconfigurationandcontrolparameters(parameterswithreadwriteaccess),
theDescriptioncolumndescribeswhenthenewvalueiseffective.Itisrecommendedthat
youperformtheappropriateactiontomakethevaluesaffectiveimmediatelyafterany
change.Whereachangeisrequiredonbothsidesofthelink,itisrecommendedthatyou
changebothsidesofthelinkfirstandthenperformtheaction.

SupportedVariablesfromtheRFC1213MIB
TableC1:SupportedVariables
Access

Name

OID

Type

ifIndex

.1.3.6.1.2.1.2.2.1.1.xa

Integer

RO

Auniquevalueforeachinterface.Itsvalue
rangesbetween1andthevalueof
ifNumber.Thevalueforeachinterfacemust
remainconstantatleastfromonere
initializationoftheentity'snetwork
managementsystemtothenextre
initialization.

ifDescr

.1.3.6.1.2.1.2.2.1.2

DisplayString

RO

Atextualstringcontaininginformation
abouttheinterface.Thisstringshould
includethenameofthemanufacturer,the
productnameandtheversionofthe
hardwareinterface.

ifType

.1.3.6.1.2.1.2.2.1.3

Integer

RO

Thetypeofinterface,distinguished
accordingtothephysical/linkprotocol(s)
immediately`below'thenetworklayerin
theprotocolstack.

ifSpeed

.1.3.6.1.2.1.2.2.1.5

Gauge

RO

Anestimateoftheinterface'scurrent
bandwidthinbitspersecond.Forinterfaces
whichdonotvaryinbandwidthorfor
thosewherenoaccurateestimationcanbe
made,thisobjectshouldontainthe
nominalbandwidth.

ifPhysAddress

.1.3.6.1.2.1.2.2.1.6

PhysAddress

RO

Theinterface'saddressattheprotocol
layerimmediately`below'thenetwork
layerintheprotocolstack.Forinterfaces
whichdonothavesuchanaddress(e.g.,a
serialline),thisobjectshouldcontainan
octetstringofzerolength.

ifAdminStatus

.1.3.6.1.2.1.2.2.1.7

Integer

RW

Thedesiredstateoftheinterface.The
testing(3)stateindicatesthatno
operationalpacketscanbepassed.

ifOperStatus

.1.3.6.1.2.1.2.2.1.8

Integer

RO

Thecurrentoperationalstateofthe
interface.Thetesting(3)stateindicates
thatnooperationalpacketscanbepassed.

ifInOctets

.1.3.6.1.2.1.2.2.1.10.x

Counter

RO

Thetotalnumberofoctetsreceivedonthe
interface,includingframingcharacters.

ifInUcastPkts

.1.3.6.1.2.1.2.2.1.11.x

Counter

RO

Thenumberofsubnetworkunicastpackets
deliveredtoahigherlayerprotocol.

ifInNUcastPkts

.1.3.6.1.2.1.2.2.1.12.x

Counter

RO

Thenumberofnonunicast(i.e.,
subnetworkbroadcastorsubnetwork
multicast)packetsdeliveredtoahigher
layerprotocol.

ifInErrors

.1.3.6.1.2.1.2.2.1.14.x

Counter

RO

Thenumberofinboundpacketsthat
containederrorspreventingthemfrom
beingdeliverabletoahigherlayer
protocol.

RADWIN5000HPMPUserManual

Release3.5.50

Description

C4

MIBParameters

TableC1:SupportedVariables
Access

Name

OID

Type

Description

ifOutOctets

.1.3.6.1.2.1.2.2.1.16.x

Counter

RO

Thetotalnumberofoctetstransmittedout
oftheinterface,includingframing
characters.

ifOutUcastPkts

.1.3.6.1.2.1.2.2.1.17.x

Counter

RO

Thetotalnumberofpacketsthathigher
levelprotocolsrequestedbetransmittedto
asubnetworkunicastaddress,including
thosethatwerediscardedornotsent.

ifOutNUcastPkts

.1.3.6.1.2.1.2.2.1.18.x

Counter

RO

Thetotalnumberofpacketsthathigher
levelprotocolsrequestedbetransmittedto
anonunicast(i.e.,asubnetwork
broadcastorsubnetworkmulticast)
address,includingthosethatwere
discardedornotsent.

a. x is the interface ID

RADWIN5000HPMPUserManual

Release3.5.50

C5

PrivateMIBParameters

PrivateMIBParameters
HBS
TableC2:PrivateMIBParametersHBS(Sheet1of33)
Access

Name

OID

Type

Description

winlink1000OduAdmProductType

1.3.6.1.4.1.4458.1000.1.1.1

DisplayString

RO

ODUconfigurationdescription.

winlink1000OduAdmHwRev

1.3.6.1.4.1.4458.1000.1.1.2

DisplayString

RO

ODUHardwareVersion.

winlink1000OduAdmSwRev

1.3.6.1.4.1.4458.1000.1.1.3

DisplayString

RO

ODUSoftwareVersion.

winlink1000OduAdmLinkName

1.3.6.1.4.1.4458.1000.1.1.4

DisplayString

RW LinkName.Achangeiseffectiveimmediately.

winlink1000OduAdmResetCmd

1.3.6.1.4.1.4458.1000.1.1.5

Integer

RW ResetCommand.Asetcommandwithavalue
of3willcauseadevicereset.HBSonly:Aset
commandwithavalueof4willcauseadevice
resetfortheentiresector.Thereadvalueis
always0.

winlink1000OduAdmAddres

1.3.6.1.4.1.4458.1000.1.1.6

IPAddress

RW ODUIPaddress.Achangeiseffectiveafterreset.
Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.

winlink1000OduAdmMask

1.3.6.1.4.1.4458.1000.1.1.7

IPAddress

RW ODUSubnetMask.Achangeiseffectiveafter
reset.Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.

winlink1000OduAdmGateway

1.3.6.1.4.1.4458.1000.1.1.8

IPAddress

RW ODUdefaultgateway.Achangeiseffectiveafter
reset.Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.

winlink1000OduAdmBroadcast

1.3.6.1.4.1.4458.1000.1.1.1
0

Integer

RW ThisparameterisreservedfortheManager
applicationprovidedwiththeproduct.

winlink1000OduAdmHostsTable

N/A Trapdestinationstable.Eachtrapdestinationis
definedbyanIPaddressandaUDPport.Upto
10addressescanbeconfigured.

winlink1000OduAdmHostsEntry

N/A Trapdestinationstableentry.INDEX{
winlink1000OduAdmHostsIndex}

winlink1000OduAdmHostsIndex

1.3.6.1.4.1.4458.1000.1.1.1
2.1.1

Integer

RO

winlink1000OduAdmHostsIp

1.3.6.1.4.1.4458.1000.1.1.1
2.1.2

IPAddress

RW TrapdestinationIPaddress.Achangeiseffective
immediately.

winlink1000OduAdmHostsPort

1.3.6.1.4.1.4458.1000.1.1.1
2.1.3

Integer

RW UDPportofthetrapdestination.Achangeis
effectiveimmediately.

winlink1000OduAdmHostsSecurity
Model

1.3.6.1.4.1.4458.1000.1.1.1
2.1.4

Integer

RW Securitymodelusedforthistrapgeneration.

winlink1000OduAdmHostsUserNam 1.3.6.1.4.1.4458.1000.1.1.1
e
2.1.5

DisplayString

RW Usernameusedtogeneratethesnmpv3trap.

winlink1000OduAdmHostsPasswor
d

1.3.6.1.4.1.4458.1000.1.1.1
2.1.6

DisplayString

RW Passwordusedtogeneratethesnmpv3trap.

winlink1000OduAdmHostsIPv6

1.3.6.1.4.1.4458.1000.1.1.1
2.1.7

DisplayString

RW TrapdestinationIPv6address.Achangeis
effectiveimmediately.

winlink1000OduBuzzerAdminState

1.3.6.1.4.1.4458.1000.1.1.1
3

Integer

RW Thisparametercontrolstheactivationofthe
buzzerwhiletheunitisininstallmode.A
changeiseffectiveimmediately.Thevalidvalues
are:disabled(0)enabledAuto(1)
enabledConstantly(2)advancedAuto(3).

winlink1000OduProductId

1.3.6.1.4.1.4458.1000.1.1.1
4

DisplayString

RO

RADWIN5000HPMPUserManual

Release3.5.50

Trapdestinationstableindex.

ThisparameterisreservedfortheManager
applicationprovidedwiththeproduct.

C6

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet2of33)
Access

Name

OID

Type

winlink1000OduReadCommunity

1.3.6.1.4.1.4458.1000.1.1.1
5

DisplayString

RW ReadCommunityString.Thisparameteralways
returns*****whenretrievingitsvalue.Itis
usedbytheManagerapplicationtochangethe
ReadCommunityString.TheSNMPagent
acceptsonlyencryptedvalues.

winlink1000OduReadWriteCommu
nity

1.3.6.1.4.1.4458.1000.1.1.1
6

DisplayString

RW Read/WriteCommunityString.Thisparameter
alwaysreturns*****whenretrievingitsvalue.
ItisusedbytheManagerapplicationtochange
theRead/WriteCommunityString.TheSNMP
agentacceptsonlyencryptedvalues.

winlink1000OduTrapCommunity

1.3.6.1.4.1.4458.1000.1.1.1
7

DisplayString

RW TrapCommunityString.Thisparameterisused
bytheManagerapplicationtochangetheTrap
CommunityString.TheSNMPagentaccepts
onlyencryptedvalues.

winlink1000OduAdmSnmpAgentVe
rsion

1.3.6.1.4.1.4458.1000.1.1.1
8

Integer

RO

MajorversionoftheSNMPagent.

winlink1000OduAdmRemoteSiteNa 1.3.6.1.4.1.4458.1000.1.1.1
me
9

DisplayString

RO

Remotesitename.Returnsthesamevalueas
sysLocationparameteroftheremotesite.

winlink1000OduAdmSnmpAgentMi 1.3.6.1.4.1.4458.1000.1.1.2
norVersion
0

Integer

RO

MinorversionoftheSNMPagent.

winlink1000OduAdmLinkPassword

1.3.6.1.4.1.4458.1000.1.1.2
1

DisplayString

RW LinkPassword.Thisparameteralwaysreturns
*****whenretrievingitsvalue.Itisusedby
theManagerapplicationtochangetheLink
Password.TheSNMPagentacceptsonly
encryptedvalues.

winlink1000OduAdmSiteLinkPassw
ord

1.3.6.1.4.1.4458.1000.1.1.2
2

DisplayString

RW SiteLinkPassword.Thisparameteralways
returns*****whenretrievingitsvalue.Itis
usedbytheManagerapplicationtochangethe
LinkPasswordofthesite.TheSNMPagent
acceptsonlyencryptedvalues.

winlink1000OduAdmDefaultPasswo 1.3.6.1.4.1.4458.1000.1.1.2
rd
3

Integer

RO

ThisparameterindicatesifthecurrentLink
Passwordisthedefaultpassword.

winlink1000OduAdmConnectionTy
pe

1.3.6.1.4.1.4458.1000.1.1.2
4

Integer

RO

ThisparameterindicatesiftheManager
applicationisconnectedtothelocalODUorto
theremoteODUovertheair.Avalueof
'unknown'indicatescommunitystring
mismatch.

winlink1000OduAdmBackToFactory 1.3.6.1.4.1.4458.1000.1.1.2
SettingsCmd
5

Integer

RW BacktofactorysettingsCommand.Achangeis
effectiveafterreset.Thereadvalueisalways
0.

winlink1000OduAdmIpParamsCnfg

1.3.6.1.4.1.4458.1000.1.1.2
6

DisplayString

RW ODUIPaddressConfiguration.Theformatis:
<IP_Address>|<Subnet_Mask>|<Default_Gatew
ay>|

winlink1000OduAdmVlanID

1.3.6.1.4.1.4458.1000.1.1.2
7

Integer

RW VLANID.Validvaluesare1to4094.Initialvalue
is0meaningVLANunaware.

winlink1000OduAdmVlanPriority

1.3.6.1.4.1.4458.1000.1.1.2
8

Integer

RW VLANPriority.0islowestpriority7ishighest
priority.

winlink1000OduAdmSN

1.3.6.1.4.1.4458.1000.1.1.2
9

DisplayString

RO

ODUSerialNumber

winlink1000OduAdmProductName

1.3.6.1.4.1.4458.1000.1.1.3
0

DisplayString

RO

ThisistheproductnameasitexistsatEC

winlink1000OduAdmActivationKey

1.3.6.1.4.1.4458.1000.1.1.3
1

DisplayString

RW Activatesageneralkey.

winlink1000OduAdmRmtPermitted
OduType

1.3.6.1.4.1.4458.1000.1.1.3
2

DisplayString

RW MobileApplication:permittedpartnerOduType.

winlink1000OduAdmCpuID

1.3.6.1.4.1.4458.1000.1.1.3
3

Integer

RO

RADWIN5000HPMPUserManual

Release3.5.50

Description

CPUID

C7

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet3of33)
Access

Name

OID

Type

Description

winlink1000OduAdmOvrdCmd

1.3.6.1.4.1.4458.1000.1.1.3
4

DisplayString

RW AbilitytoperformspecialcommandintheODU.

winlink1000OduAdmLinkMode

1.3.6.1.4.1.4458.1000.1.1.3
5

Integer

RW UnitPMPoperationmode.

winlink1000OduAdmActualConnect 1.3.6.1.4.1.4458.1000.1.1.3
Mode
6

Integer

RO

Unitconnectedasparttoptporptmp.

winlink1000OduAdmAES256Suppor 1.3.6.1.4.1.4458.1000.1.1.3
t
7

Integer

RO

AES256securitysupportindication.

winlink1000OduAdmAES256State

1.3.6.1.4.1.4458.1000.1.1.3
8

Integer

RW Enable/DisableAES256securitymodeoverthe
airlink.

winlink1000OduAdmAES256Status

1.3.6.1.4.1.4458.1000.1.1.3
9

Integer

RO

winlink1000OduAdmBatterySavingS 1.3.6.1.4.1.4458.1000.1.1.4
hutdownTime
0

Integer

RW BatterySavingShutdownTimeinminutes0till
batteryrunout1ifnotsupported.

winlink1000OduAdmWiFiPowerMo 1.3.6.1.4.1.4458.1000.1.1.4
de
1

Integer

RW WIFIunitpowermode.

winlink1000OduAdmShutdownTim
er

1.3.6.1.4.1.4458.1000.1.1.4
2

Integer

RO

ShutdownTimerinseconds.

winlink1000OduAdmGPSState

1.3.6.1.4.1.4458.1000.1.1.4
3

Integer

RO

GPSstate

winlink1000OduAdmTemperatureC

1.3.6.1.4.1.4458.1000.1.1.4
4

Integer

RO

Thetemperature(Celsius)insidetheBoard.

winlink1000OduAdmIPStackMode

1.3.6.1.4.1.4458.1000.1.1.4
5

Integer

RW TheIPstackmode.

winlink1000OduAdmIPv6ParamsCnf 1.3.6.1.4.1.4458.1000.1.1.4
g
6

DisplayString

RW ODUIPv6addressConfiguration.Theformatis:
<IP_Address>|<Subnet_Mask>|<Default_Gatew
ay>|

winlink1000OduAdmIPv6Address

1.3.6.1.4.1.4458.1000.1.1.4
7

DisplayString

RO

ODUIPv6address.

winlink1000OduAdmIPv6Prefix

1.3.6.1.4.1.4458.1000.1.1.4
8

Integer

RO

ODUIPv6subnetmask.

winlink1000OduAdmIPv6DefaultGa 1.3.6.1.4.1.4458.1000.1.1.4
teWay
9

DisplayString

RO

ODUIPv6defaultgateway.

winlink1000OduSrvMode

1.3.6.1.4.1.4458.1000.1.2.1

Integer

RW Systemmode.Theonlyvaluesthatcanbeset
areinstallModeandslaveMode;normalMode
reservedtotheManagerapplicationprovided
withtheproduct.Achangeiseffectiveafter
linkresynchronization.

winlink1000OduSrvBridging

1.3.6.1.4.1.4458.1000.1.2.3

Integer

RO

AES256operatingstatus

BridgingMode.Validvaluesare:disabled(0)
enabled(1).

winlink1000OduSrvRingLinkMode

RW Modeofthelinkregardingringtopology.

winlink1000OduSrvRingTopologySu
pported

RO

winlink1000OduSrvRingVlanIdTable

N/A RingVLANIDstable.

winlink1000OduSrvRingVlanIdEntry

N/A VLANIDoftheinternalringmessages.Valid
valuesare1to4094.Initialvalueis0meaning
VLANunaware.INDEX{
winlink1000OduSrvRingVlanIdIndex}

winlink1000OduSrvRingVlanIdIndex

RO

winlink1000OduSrvRingVlanId

RW VLANIDoftheinternalringmessages.Valid
valuesare1to4094.Initialvalueis0meaning
VLANunaware.

winlink1000OduSrvRingEthStatus

RO

winlink1000OduSrvRingMaxAllowe
dTimeFromLastRpm

RW Definestheminimaltime(inms)requiredfor
determinationofringfailure.

RADWIN5000HPMPUserManual

Release3.5.50

RingTopologyoptionsare:supportednot
supported

IndexofVLANIDoftheinternalringmessages.

RepresentstheEthernetserviceblockingstate
ofaRingslink

C8

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet4of33)
OID

Type

Access

Name

Description

winlink1000OduSrvRingWTR

RW Definestheminimaltime(inms)requiredfor
ringrecovery.

winlink1000OduSrvQoSMode

RW ModeofQoSfeature.

winlink1000OduSrvQoSConfTable

N/A QoSconfigurationtable.

winlink1000OduSrvQoSConfEntry

N/A QoSconfigurationtable.INDEX{
winlink1000OduSrvQoSConfIndex}

winlink1000OduSrvQoSConfIndex

RO

IndexofQoSConfiguration.

winlink1000OduSrvConfVlanQGrou
ps

RO

FramesclassificationaccordingtoVLANPriority
IDs.

winlink1000OduSrvConfDiffservQGr
oups

RO

FramesclassificationaccordingtoDiffserv.

winlink1000OduSrvConfQueMir

RW DesiredPrivateMIR.

winlink1000OduSrvConfQueWeight

RW QoSqueueu'sweightsinpercent.

winlink1000OduSrvQoSVlanQGroup
sSetStr

RW FramesclassificationaccordingtoVLANIDs
stringforset.

winlink1000OduSrvQoSDiffservQGr
oupsSetStr

RW FramesclassificationaccordingtoDiffservIDs
stringforset.

winlink1000OduSrvQoSMaxRTQueP
ercent

RO

MaximalpercentforRT&NRTqueues.

winlink1000OduSrvVlanSupport

RO

ODUEthernetportVLANsupportand
configurationavailabilityindication.1ODU
VLANFunctionalityNotSupported2ODU
VLANFunctionalitySupported3ODUVLAN
FunctionalitySupportedandAvailable

winlink1000OduSrvVlanIngressMod
e

RW ODUEthernetportingressVLANmode.

winlink1000OduSrvVlanEgressMod
e

RW ODUEthernetportegressVLANmode.

winlink1000OduSrvEgressTag

RW ODUethernetportegressVLANtag.Right
mostdigitisVlanpriority(07)otherdigits
composeVlanId(24094)

winlink1000OduSrvEgressProviderT
ag

RW ODUethernetportegressProviderVLANtag.
RightmostdigitisVlanpriority(07)other
digitscomposeVlanId(24094)

winlink1000OduSrvVlanIngressAllo
wedVIDs

RW ODUethernetportVLANIDsthatwillnotbe
filteredoningress.w|w|w|w|w|w|w|w|(
wherew={04094}andw!=1)

winlink1000OduSrvVlanDisable

RW DisableVLANfunctionality.Thefollowingvalues
canbeset:3DisableODU&IDUVLAN
Configurations.

winlink1000OduServiceVlanProvide 1.3.6.1.4.1.4458.1000.1.2.6. DisplayString


rListTPIDstr
8

RO

HoldsthepossibleProviderTPIDs.

winlink1000OduEthernetRemaining 1.3.6.1.4.1.4458.1000.1.3.1
Rate

RO

CurrentEthernetbandwidthinbps.

Integer

winlink1000OduEthernetIfTable

N/A ODUEthernetInterfacetable.

winlink1000OduEthernetIfEntry

N/A ODUEthernetInterfacetableentry.INDEX{
winlink1000OduEthernetIfIndex}

winlink1000OduEthernetIfIndex

1.3.6.1.4.1.4458.1000.1.3.2. Integer
1.1

RO

ODUEthernetInterfaceIndex.

winlink1000OduEthernetIfAddress

1.3.6.1.4.1.4458.1000.1.3.2. DisplayString
1.5

RO

ODUMACaddress.

winlink1000OduEthernetIfAdminSt
atus

1.3.6.1.4.1.4458.1000.1.3.2. Integer
1.6

RW Requiredstateoftheinterface.

winlink1000OduEthernetIfOperStat 1.3.6.1.4.1.4458.1000.1.3.2. Integer


us
1.7

RADWIN5000HPMPUserManual

Release3.5.50

RO

Currentoperationalstateoftheinterface.

C9

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet5of33)
OID

Type

winlink1000OduEthernetIfFailActio
n

1.3.6.1.4.1.4458.1000.1.3.2. Integer
1.8

Access

Name

Description

RW Failureactionoftheinterface.

winlink1000OduEthernetNumOfPor 1.3.6.1.4.1.4458.1000.1.3.3
ts

Integer

RO

NumberofODUnetworkinterfaces.

winlink1000OduEthernetGbeSuppo 1.3.6.1.4.1.4458.1000.1.3.4
rted

Integer

RO

SupportedGigabitEthernetinODU.

winlink1000OduBridgeBasePortTabl
e

N/A ODUBridgePortstable.

winlink1000OduBridgeBasePortEntr
y

N/A ODUBridgePortstableentry.INDEX{
winlink1000OduBridgeBasePortIndex}

winlink1000OduBridgeBasePortInd
ex

RO

ODUBridgePortNumber.

winlink1000OduBridgeBaseIfIndex

RO

IfIndexcorrespondingtoODUBridgeport.

winlink1000OduBridgeTpMode

1.3.6.1.4.1.4458.1000.1.4.4. Integer
101

RW ODUbridgemode.Achangeiseffectiveafter
reset.Validvalues:hubMode(0)bridgeMode
(1).

winlink1000OduBridgeTpPortTable

N/A ODUTransparentBridgePortstable.

winlink1000OduBridgeTpPortEntry

N/A ODUTransparentBridgePortstableentry.
INDEX{winlink1000OduBridgeTpPortIndex}

winlink1000OduBridgeTpPortIndex

1.3.6.1.4.1.4458.1000.1.4.4. Integer
3.1.1

RO

ODUTransparentBridgePortNumber.

winlink1000OduBridgeTpPortInFra
mes

1.3.6.1.4.1.4458.1000.1.4.4. Counter
3.1.3

RO

Numberofframesreceivedbythisport.

winlink1000OduBridgeTpPortOutFr
ames

1.3.6.1.4.1.4458.1000.1.4.4. Counter
3.1.4

RO

Numberofframestransmittedbythisport.

winlink1000OduBridgeTpPortInByte 1.3.6.1.4.1.4458.1000.1.4.4. Counter


s
3.1.101

RO

Numberofbytesreceivedbythisport.

winlink1000OduBridgeTpPortOutBy 1.3.6.1.4.1.4458.1000.1.4.4. Counter


tes
3.1.102

RO

Numberofbytestransmittedbythisport.

winlink1000OduBridgeConfigMode

1.3.6.1.4.1.4458.1000.1.4.4. Integer
102

RO

ODUbridgeconfigurationmode

winlink1000OduAirFreq

1.3.6.1.4.1.4458.1000.1.5.1

Integer

RW InstallationCenterFrequency.Validvaluesare
productdependent.Achangeiseffectiveafter
linkresynchronization.

winlink1000OduAirDesiredRate

1.3.6.1.4.1.4458.1000.1.5.2

Integer

RW Deprecatedparameteractualbehaviorisread
only.RequiredAirRate.ForChannel
Bandwidthof20105MHzdividethevalueby
124respectively.

winlink1000OduAirSSID

1.3.6.1.4.1.4458.1000.1.5.3

DisplayString

RW ReservedfortheManagerapplicationprovided
withtheproduct.TheSectorIDinPointTo
MultiPointsystems.

winlink1000OduAirTxPower

1.3.6.1.4.1.4458.1000.1.5.4

Integer

RW RequiredTransmitpowerindBm.Thisisa
nominalvaluewhiletheactualtransmitpower
includesadditionalattenuation.Theminand
maxvaluesareproductspecific.Achangeis
effectiveimmediately.

winlink1000OduAirSesState

1.3.6.1.4.1.4458.1000.1.5.5

Integer

RO

CurrentLinkState.Thevalueisactive(3)during
normaloperation.

winlink1000OduAirMstrSlv

1.3.6.1.4.1.4458.1000.1.5.6

Integer

RO

Thisparameterindicatesifthedevicewas
automaticallyselectedintotheradiolinkmaster
orslave.Thevalueisundefinedifthereisno
link.Thevalueisrelevantonlyforpointto
pointsystems.

winlink1000OduAirResync

1.3.6.1.4.1.4458.1000.1.5.8

Integer

RW Settingthisparameterto1willcausethelinkto
restartthesynchronizationprocess.

RADWIN5000HPMPUserManual

Release3.5.50

C10

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet6of33)
Type

Access

Name

OID

winlink1000OduAirRxPower

1.3.6.1.4.1.4458.1000.1.5.9. Integer
1

RO

ReceivedSignalStrengthindBm.Relevantonly
forpointtopointsystems.

winlink1000OduAirTotalFrames

1.3.6.1.4.1.4458.1000.1.5.9. Counter
2

RO

Totalnumberofradioframes.

winlink1000OduAirBadFrames

1.3.6.1.4.1.4458.1000.1.5.9. Counter
3

RO

TotalnumberofreceivedradioframeswithCRC
error.Thevalueisrelevantonlyforpointto
pointsystems.

winlink1000OduAirCurrentRate

1.3.6.1.4.1.4458.1000.1.5.9. Integer
4

RO

Deprecatedparameter.Actualrateoftheair
interfaceinMbps.ForChannelBandwidthof
20105MHzdividethevalueby124
respectively.

winlink1000OduAirCurrentRateIdx

1.3.6.1.4.1.4458.1000.1.5.9. Integer
5

RO

Indexofcurrentairrate.

RO

ReceivedSignalStrengthofCpechainsindBm.
Chain1RSS:(1Byte)Chain2RSS:(1Byte)
Chain3RSS:(1Byte)

winlink1000OduAirChainsRxPower

Description

winlink1000OduAirTxPower36

1.3.6.1.4.1.4458.1000.1.5.1
0

Integer

RW Deprecatedparameter.Actualbehaviorisread
only.

winlink1000OduAirTxPower48

1.3.6.1.4.1.4458.1000.1.5.1
1

Integer

RW Deprecatedparameter.Actualbehaviorisread
only.

winlink1000OduAirCurrentTxPower 1.3.6.1.4.1.4458.1000.1.5.1
2

Integer

RO

CurrentTransmitPowerindBm.Thisisa
nominalvaluewhiletheactualtransmitpower
includesadditionalattenuation.

winlink1000OduAirMinFrequency

1.3.6.1.4.1.4458.1000.1.5.1
3

Integer

RO

MinimumcenterfrequencyinMHz.

winlink1000OduAirMaxFrequency

1.3.6.1.4.1.4458.1000.1.5.1
4

Integer

RO

MaximumcenterfrequencyinMHz.

winlink1000OduAirFreqResolution

1.3.6.1.4.1.4458.1000.1.5.1
5

Integer

RO

CenterFrequencyresolution.Measuredin
MHzifvalue<100otherwiseinKHz.

winlink1000OduAirCurrentFreq

1.3.6.1.4.1.4458.1000.1.5.1
6

Integer

RO

CurrentCenterFrequency.MeasuredinMHzif
centerfrequencyresolutionvalue<100
otherwiseinKHz.

winlink1000OduAirNumberOfChan
nels

1.3.6.1.4.1.4458.1000.1.5.1
7

Integer

RO

Numberofchannelsthatcanbeused.

winlink1000OduAirChannelsTable

N/A Tableofchannelsusedbyautomaticchannels
selection(ACS).

winlink1000OduAirChannelsEntry

N/A ACSchannelstableentry.INDEX{
winlink1000OduAirChannelsIndex}

winlink1000OduAirChannelsIndex

RO

ChannelIndex.

winlink1000OduAirChannelsFreque
ncy

RO

ChannelfrequencyinMHz.

winlink1000OduAirChannelsOperSt
ate

RW Channelstate.Canbesetbytheuser.
AutomaticChannelSelectionuseschannelsthat
areAirChannelsOperStateenabledand
AirChannelsAvailenabled.Achangeis
effectiveafterlinkresynchronization.Valid
values:disabled(0)enabled(1).Rewriteable
onlyinPointToPointproducts.

winlink1000OduAirChannelsAvail

RO

Channelstate.Productspecificandcannotbe
changedbytheuser.AutomaticChannel
Selectionuseschannelsthatare
AirChannelsOperStateenabledand
AirChannelsAvailenabled.Validvalues:
disabled(0)enabled(1).

winlink1000OduAirChannelsDefault
Freq

RO

Defaultchannel'savailabilityforallCBWs.The
validvaluesare:forbidden(0)available(1).

RADWIN5000HPMPUserManual

Release3.5.50

C11

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet7of33)
Access

Name

OID

Type

Description

winlink1000OduAirDfsState

1.3.6.1.4.1.4458.1000.1.5.1
9

Integer

RO

Radardetectionstate.Validvalues:disabled(0)
enabled(1).

winlink1000OduAirAutoChannelSel
ectionState

1.3.6.1.4.1.4458.1000.1.5.2
0

Integer

RO

Deprecatedparameter.IndicatingAutomatic
ChannelSelectionavailabilityatcurrentchannel
bandwidth.Validvalues:disabled(0)enabled
(1).

winlink1000OduAirEnableTxPower

1.3.6.1.4.1.4458.1000.1.5.2
1

Integer

RO

IndicatingTransmitpowerconfiguration
enabledordisabled.

winlink1000OduAirMinTxPower

1.3.6.1.4.1.4458.1000.1.5.2
2

Integer

RO

MinimumTransmitpowerindBm.

winlink1000OduAirMaxTxPowerTab
le

N/A TableofMaximumtransmitpowerperairrate
indBm.

winlink1000OduAirMaxTxPowerEnt
ry

N/A MaximumTransmitpowertableentry.INDEX{
winlink1000OduAirMaxTxPowerIndex}

winlink1000OduAirMaxTxPowerInd
ex

1.3.6.1.4.1.4458.1000.1.5.2
3.1.1

Integer

RO

Airinterfacerateindex.

winlink1000OduAirMaxTxPower

1.3.6.1.4.1.4458.1000.1.5.2
3.1.2

Integer

RO

MaximumTransmitpowerindBm.

winlink1000OduAirChannelBandwi
dth

1.3.6.1.4.1.4458.1000.1.5.2
4

Integer

RW ChannelbandwidthinKHz.Achangeiseffective
afterreset.

winlink1000OduAirChannelBWTabl
e

N/A ChannelBandwidthstable.

winlink1000OduAirChannelBWEntr
y

N/A ChannelBandwidthtableentry.INDEX{
winlink1000OduAirChannelBWIndex}

winlink1000OduAirChannelBWInde 1.3.6.1.4.1.4458.1000.1.5.2
x
5.1.1

Integer

RO

ChannelBandwidthindex.

winlink1000OduAirChannelBWAvail 1.3.6.1.4.1.4458.1000.1.5.2
5.1.2

Integer

RO

ChannelBandwidthavailabilityproduct
specific.Optionsare:Notsupportedsupported
withmanualchannelselectionsupportedwith
AutomaticChannelSelection.

winlink1000OduAirChannelsAdmin
State

1.3.6.1.4.1.4458.1000.1.5.2
5.1.3

DisplayString

RO

Channels'availabilityperCBW.

winlink1000OduAirChannelBWHSS
ATDDConflictPerCBW

1.3.6.1.4.1.4458.1000.1.5.2
5.1.4

Integer

RO

IndicationforpossibleLinkdropperCBWdueto
conflictbetweenHSSandATDD.

winlink1000OduAirChannelBWMin
RatioForSupporting

1.3.6.1.4.1.4458.1000.1.5.2
5.1.5

Integer

RO

MinimalTXratiothatmaybeusedbytheHSM
andstillenableproperoperationofthe
aforementionedCBW.

winlink1000OduAirChannelBWMax
RatioForSupporting

1.3.6.1.4.1.4458.1000.1.5.2
5.1.6

Integer

RO

MaximalTXratiothatmaybeusedbytheHSM
andstillenableproperoperationofthe
aforementionedCBW.

winlink1000OduAirRFD

1.3.6.1.4.1.4458.1000.1.5.2
6

Integer

RO

Currentradioframedurationinmicroseconds.

winlink1000OduAirRatesTable

N/A AirRateindexestableforcurrentchannel
bandwidth.

winlink1000OduAirRatesEntry

N/A AirRateindexestableentry.INDEX{
winlink1000OduAirRatesIndex}

winlink1000OduAirRatesIndex

RO

AirRateindex.

winlink1000OduAirRatesAvail

RO

AirRateavailabilitydependingonairinterface
conditions.

winlink1000OduAirDesiredRateIdx

1.3.6.1.4.1.4458.1000.1.5.2
8

Integer

RW RequiredAirRateindex.0reservedforAdaptive
Rate.Achangeiseffectiveimmediatelyafter
Setoperationtothemastersidewhilethelink
isup.

winlink1000OduAirLinkDistance

1.3.6.1.4.1.4458.1000.1.5.2
9

Integer

RO

RADWIN5000HPMPUserManual

Release3.5.50

Linkdistanceinmeters.Avalueof1indicates
anillegalvalueandisalsousedwhenalinkis
notestablished.

C12

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet8of33)
Access

Name

OID

Type

Description

winlink1000OduAirLinkWorkingMo
de

1.3.6.1.4.1.4458.1000.1.5.3
0

Integer

RO

Linkworkingmodeasaresultofcomparing
versionsofbothsidesofthelink.Possible
modesare:UnknownnolinkNormalversions
onbothsidesareidenticalwithfull
compatibilitywithrestrictedcompatibilityor
versionsonbothsidesaredifferentwith
softwareupgradeorversionsincompatibility.

winlink1000OduAirMajorLinkIfVersi 1.3.6.1.4.1.4458.1000.1.5.3
on
1

Integer

RO

Majorlinkinterfaceversion

winlink1000OduAirMinorLinkIfVersi 1.3.6.1.4.1.4458.1000.1.5.3
on
2

Integer

RO

Minorlinkinterfaceversion

winlink1000OduAirHssDesiredOpSt
ate

1.3.6.1.4.1.4458.1000.1.5.4
0.1

Integer

RW RequiredHubSiteSynchronizationoperating
state.ForHssSyncUnits:ForhssISU:[27]For
hssGSU:[26]ForHBS:[2345]

winlink1000OduAirHssCurrentOpSt
ate

1.3.6.1.4.1.4458.1000.1.5.4
0.2

Integer

RO

CurrentHubSiteSynchronizationoperating
state.

winlink1000OduAirHssSyncStatus

1.3.6.1.4.1.4458.1000.1.5.4
0.3

Integer

RO

HubSiteSynchronizationsyncstatus.

winlink1000OduAirHssExtPulseStat
us

1.3.6.1.4.1.4458.1000.1.5.4
0.4

Integer

RO

HubSiteSynchronizationexternalpulse
detectionstatus.InGSSmode:ifgenerating
then1PSPisautogeneratedbytheGSSUnit.if
generatingAndDetectingthen1PSPisgenerated
byGPSsatellitessignal.

winlink1000OduAirHssExtPulseType 1.3.6.1.4.1.4458.1000.1.5.4
0.5

Integer

RO

HubSiteSynchronizationexternalpulsetype.

winlink1000OduAirHssDesiredExtPu 1.3.6.1.4.1.4458.1000.1.5.4
lseType
0.6

Integer

RW HubSiteSynchronizationrequiredexternal
pulsetype.Validvaluesforreadwrite:
{typeA(2)typeB(3)typeC(4)typeD(5)typeE(6)
typeF(7)}.Validvalueforreadonly:
{notApplicable(1)}.

winlink1000OduAirHssRfpTable

N/A ODURadioFramePatterns(RFP)Table.

winlink1000OduAirHssRfpEntry

N/A ODURFPTableentry.INDEX{
winlink1000OduAirHssRfpIndex}

winlink1000OduAirHssRfpIndex

1.3.6.1.4.1.4458.1000.1.5.4
0.7.1.1

Integer

RO

ODURFPTableindex.Theindexrepresentthe
RadioFramePattern:typeA(2)typeB(3)
typeC(4)typeD(5)typeE(6).

winlink1000OduAirHssRfpEthChann 1.3.6.1.4.1.4458.1000.1.5.4
elBW5MHz
0.7.1.2

Integer

RO

RepresentsthecompatibilityofEthernetservice
underChannelBWof5MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpTdmChan 1.3.6.1.4.1.4458.1000.1.5.4
nelBW5MHz
0.7.1.3

Integer

RO

RepresentsthecompatibilityofTDMservice
underChannelBWof5MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpEthChann 1.3.6.1.4.1.4458.1000.1.5.4
elBW10MHz
0.7.1.4

Integer

RO

RepresentsthecompatibilityofEthernetservice
underChannelBWof10MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpTdmChan 1.3.6.1.4.1.4458.1000.1.5.4
nelBW10MHz
0.7.1.5

Integer

RO

RepresentsthecompatibilityofTDMservice
underChannelBWof10MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpEthChann 1.3.6.1.4.1.4458.1000.1.5.4
elBW20MHz
0.7.1.6

Integer

RO

RepresentsthecompatibilityofEthernetservice
underChannelBWof20MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpTdmChan 1.3.6.1.4.1.4458.1000.1.5.4
nelBW20MHz
0.7.1.7

Integer

RO

RepresentsthecompatibilityofTDMservice
underChannelBWof20MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpEthChann 1.3.6.1.4.1.4458.1000.1.5.4
elBW40MHz
0.7.1.8

Integer

RO

RepresentsthecompatibilityofEthernetservice
underChannelBWof40MHzinthespecific
RadioFramePattern.

RADWIN5000HPMPUserManual

Release3.5.50

C13

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet9of33)
OID

Type

Access

Name

Description

winlink1000OduAirHssRfpTdmChan 1.3.6.1.4.1.4458.1000.1.5.4
nelBW40MHz
0.7.1.9

Integer

RO

RepresentsthecompatibilityofTDMservice
underChannelBWof40MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpStr

1.3.6.1.4.1.4458.1000.1.5.4
0.8

DisplayString

RO

HubSiteSynchronizationsupportedpatterns

winlink1000OduAirHssHsmID

1.3.6.1.4.1.4458.1000.1.5.4
0.9

Integer

RO

AuniqueIDwhichiscommontotheHSMand
allitscollocatedODUs

winlink1000OduAirHssTime

1.3.6.1.4.1.4458.1000.1.5.4
0.10

DisplayString

RO

HubSiteSynchronizationGPStime

winlink1000OduAirHssLatitude

1.3.6.1.4.1.4458.1000.1.5.4
0.11

DisplayString

RO

HubSiteSynchronizationGPSLatitude

winlink1000OduAirHssNSIndicator

1.3.6.1.4.1.4458.1000.1.5.4
0.12

DisplayString

RO

HubSiteSynchronizationGPSN/SIndicator

winlink1000OduAirHssLongitude

1.3.6.1.4.1.4458.1000.1.5.4
0.13

DisplayString

RO

HubSiteSynchronizationGPSLongitude

winlink1000OduAirHssEWIndicator

1.3.6.1.4.1.4458.1000.1.5.4
0.14

DisplayString

RO

HubSiteSynchronizationGPSE/WIndicator

winlink1000OduAirHssNumSatellite 1.3.6.1.4.1.4458.1000.1.5.4
s
0.15

DisplayString

RO

HubSiteSynchronizationGPSNumberof
satellites

winlink1000OduAirHssAltitude

1.3.6.1.4.1.4458.1000.1.5.4
0.16

DisplayString

RO

HubSiteSynchronizationGPSAltitude

winlink1000OduAirHssRfpPhase

1.3.6.1.4.1.4458.1000.1.5.4
0.17

Integer

RW HubSiteSynchronizationGPSRFPphase

winlink1000OduAirHssInterSiteSync 1.3.6.1.4.1.4458.1000.1.5.4
hronizationMode
0.18

Integer

RW InterSiteSynchronizationModeindependent/
synchronized

winlink1000OduAirHssInterSiteSync 1.3.6.1.4.1.4458.1000.1.5.4
hronizationAvailability
0.19

Integer

RO

winlink1000OduAirHssSatellitesSatS
yncRequired
winlink1000OduAirHssDomainID

InterSiteSynchronizationAvailability

RW SatellitesSynchronizationIsRequired
1.3.6.1.4.1.4458.1000.1.5.4
0.21

DisplayString

RW EHSSdomain.IndentifysetofCUswithsame
HSSsynchronization

winlink1000OduAirHssSupportedSy 1.3.6.1.4.1.4458.1000.1.5.4
nchronizationProtocol
0.22

Integer

RO

winlink1000OduAirHssDesiredSync
hronizationProtocol

1.3.6.1.4.1.4458.1000.1.5.4
0.23

Integer

RW DesiredSynchronizationProtocols

winlink1000OduAirHssDiscover

1.3.6.1.4.1.4458.1000.1.5.4
0.24

Integer

RW InitiateDiscoveryprocessofODUsonthe
network.

winlink1000OduAirHssNumberOfDi 1.3.6.1.4.1.4458.1000.1.5.4
scoveredODUs
0.25

Integer

RO

SupportedSynchronizationProtocols

NumberOFDiscoveredODUsinnetwork.

winlink1000OduAirHssDiscoverTabl
e

N/A HSSDiscoverTable.

winlink1000OduAirHssDiscoverEntr
y

N/A ODUDiscoverTableentry.INDEX{
winlink1000OduAirHssDiscoverIndex}

winlink1000OduAirHssDiscoverInde
x

RO

HSSDiscoverTableIndex.

winlink1000OduAirHssDiscoverODU
Description

RO

HoldODUHSSstatusincompressformat:
DomainIPHSSRoleHsssupportEnabledHSS
protocolSyncStatusLocationIPv6.

winlink1000OduAirHssMasterSlave
Compatibility

1.3.6.1.4.1.4458.1000.1.5.4
0.27

Integer

RO

EHSMversioncompatibility.Relevantto
EthernetHSSClientsonly.

winlink1000OduAirHssNumberOfAs 1.3.6.1.4.1.4458.1000.1.5.4
sociatedCU
0.28

Integer

RO

NumberofassociatedEthernetHSSClients.
RelevanttoEthernetHSSMastersonly

winlink1000OduAirHssAssociatedC
UTable

RADWIN5000HPMPUserManual

N/A AssociatedEthernetHSSClientsTable.Releant
forEthernetHSSMastersonly.

Release3.5.50

C14

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet10of33)
OID

Type

winlink1000OduAirHssAssociatedC
UTableEntry

Access

Name

Description

N/A AssociatedEthernetHSSClientsTableEntry.
ReleantforEthernetHSSMastersonly.INDEX{
winlink1000OduAirHssAssociatedCUIndex}

winlink1000OduAirHssAssociatedC
UIndex

1.3.6.1.4.1.4458.1000.1.5.4
0.29.1.1

Integer

RO

AssociatedEthernetHSSClientsTableIndex.
ReleantforEthernetHSSMastersonly.

winlink1000OduAirHssAssociatedC
UDescription

1.3.6.1.4.1.4458.1000.1.5.4
0.29.1.2

DisplayString

RO

HoldsAssociatedEthernetHSSClients
Descriptionincompressformat:IPDelay
CompatibilityEthernetSpeedEthernetRxrate
IPv6

winlink1000OduAirHssSyncStatusEt 1.3.6.1.4.1.4458.1000.1.5.4
h
0.30

Integer

RO

EthernetHSSClientSynchronizationLevel

winlink1000OduAirHssEthVLANTag

1.3.6.1.4.1.4458.1000.1.5.4
0.31

Integer

RW EthernetHSSVLanTag:Theleastsignificate
decimaldigitistheVLanPriority(06)andthe
restofthedigitsrepresentsVLanID(24094)

winlink1000OduAirHssHSMIPAddre
ss

1.3.6.1.4.1.4458.1000.1.5.4
0.32

IPAddress

RO

HSMsIPaddress.RelevantforHSCsynchronized
overEthernet.

winlink1000OduAirHssDelayToHSM

1.3.6.1.4.1.4458.1000.1.5.4
0.33

Integer

RO

DelayinmicrosecondstoHSM.RelevantforHSC
synchronizedoverEthernet.

winlink1000OduAirHssSyncAcquisiti 1.3.6.1.4.1.4458.1000.1.5.4
onSeconds
0.34

Integer

RW Accumulatedquantityofsecondsinclock
acquisitionwhileconnectedtocurrentHSM

winlink1000OduAirHssHSMIPv6Add 1.3.6.1.4.1.4458.1000.1.5.4
ress
0.35

DisplayString

RO

winlink1000OduAirLockRemote

1.3.6.1.4.1.4458.1000.1.5.4
1

Integer

RW Thisparameterenableslockingthelinkwitha
specificODU.Thefollowingvaluescanbeset:
Unlock(default)TheODUisnotlockedona
specificremoteODU.Unlockcanonlybe
performedwhenthelinkisnotconnected.
LockTheODUislockedonaspecificremote
ODU.Lockcanonlybeperformedwhenthelink
isactive.

winlink1000OduAirAntennaGain

1.3.6.1.4.1.4458.1000.1.5.4
2

Integer

RW CurrentAntennaGainin0.1dBiresolution.User
definedvalueforexternalantenna.Legal
range:
MinAntennaGain<AntennaGain<MaxAntennaG
ain.

winlink1000OduAirFeederLoss

1.3.6.1.4.1.4458.1000.1.5.4
3

Integer

RW CurrentFeederLossin0.1dBmresolution.User
definedvalueforexternalantenna.

winlink1000OduAirMaxAntennaGai 1.3.6.1.4.1.4458.1000.1.5.4
n
4

Integer

RO

MaximumallowedAntennaGainin0.1dBi
resolution.

winlink1000OduAirMinAntennaGai
n

1.3.6.1.4.1.4458.1000.1.5.4
5

Integer

RO

MinimumallowedAntennaGainin0.1dBi
resolution.

winlink1000OduAirMaxEIRP

1.3.6.1.4.1.4458.1000.1.5.4
6

Integer

RO

MaximumEIRPvalueasdefinedbyregulationin
0.1dBmresolution.

winlink1000OduAirAntennaGainCo
nfigSupport

1.3.6.1.4.1.4458.1000.1.5.4
7

Integer

RO

AntennaGainConfigurabilityoptionsare
productspecific:supportednotsupported.

winlink1000OduAirAntennaType

1.3.6.1.4.1.4458.1000.1.5.4
8

Integer

RW ExternalAntennaType:MonopolarorBipolar.

winlink1000OduAirRssBalance

1.3.6.1.4.1.4458.1000.1.5.4
9

Integer

RO

RSSbalance.RelationbetweenRSSinradio1
andRSSinradio2.2:Radio2RSSismuch
strongerthanRadio1RSS.1:Radio2RSSis
strongerthanRadio1RSS.0:Radio2RSSis
equaltoRadio1RSS.1:Radio1RSSisstronger
thanRadio2RSS.2:Radio1RSSismuch
strongerthanRadio2RSS.

winlink1000OduAirTotalTxPower

1.3.6.1.4.1.4458.1000.1.5.5
0

Integer

RO

TotalTransmitPowerindBm.Thisisanominal
valueWhiletheactualtransmitpowerincludes
additionalattenuation.

RADWIN5000HPMPUserManual

Release3.5.50

HSMsIPv6address.RelevantforHSC
synchronizedoverEthernet.

C15

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet11of33)
Access

Name

OID

Type

Description

winlink1000OduAirInstallFreqAndC
BW

1.3.6.1.4.1.4458.1000.1.5.5
1

DisplayString

RW InstallationfrequencyChannelBW.Relevantin
pointtopointsystems.

winlink1000OduAirDFStype

1.3.6.1.4.1.4458.1000.1.5.5
2

Integer

RO

DFSregulationtype.

winlink1000OduAirComboSubBand
Table

N/A ODUMultibandSubBandsTable.

winlink1000OduAirComboSubBand
Entry

N/A ODUMultibandSubBandsTableentry.INDEX
{winlink1000OduAirComboSubBandIndex}

winlink1000OduAirComboSubBandI 1.3.6.1.4.1.4458.1000.1.5.5
ndex
3.1.1.1

Integer

RO

ODUMultibandsubbandstableindex.

winlink1000OduAirComboSubBandI 1.3.6.1.4.1.4458.1000.1.5.5
d
3.1.1.2

DisplayString

RO

RepresentstheMultibandsubbandID.

winlink1000OduAirComboSubBand
Description

DisplayString

RO

Multibandsubbanddescription.

winlink1000OduAirComboSubBandI 1.3.6.1.4.1.4458.1000.1.5.5
nstallFreq
3.1.1.4

Integer

RO

RepresentstheMultibandsubbandinstallation
frequencyinKHz.

winlink1000OduAirComboSubBand
AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.5

Integer

RO

RepresentstheMultibandsubband
administrativestate.

winlink1000OduAirComboSubBandI 1.3.6.1.4.1.4458.1000.1.5.5
nstallationAllowed
3.1.1.6

Integer

RO

ReflectsiftheMultibandsubbandallowes
installtion.

winlink1000OduAirComboFrequenc 1.3.6.1.4.1.4458.1000.1.5.5
yBandId
3.1.1.7

Integer

RO

ReflectsthefrequencybandId.

winlink1000OduAirComboSubBand
ChannelBW5AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.8

DisplayString

RO

ReflectstheCBW5MHzadminstatevector.

winlink1000OduAirComboSubBand
ChannelBW10AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.9

DisplayString

RO

ReflectstheCBW10MHzadminstatevector.

winlink1000OduAirComboSubBand
ChannelBW20AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.10

DisplayString

RO

ReflectstheCBW20MHzadminstatevector.

winlink1000OduAirComboSubBand
ChannelBW40AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.11

DisplayString

RO

ReflectstheCBW40MHzadminstatevector.

winlink1000OduAirComboSubBand
AllowableChannels

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.12

DisplayString

RO

Reflectstheallowablechannelsvector.

winlink1000OduAirComboSubBand
ChannelBWAvail

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.13

DisplayString

RO

ReflectstheavailableCBWsvector.

winlink1000OduAirComboSubBand
ChannelBandwidth

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.14

Integer

RO

Reflectsthesubbanddefaultchannel
bandwidth.

winlink1000OduAirComboSubBand
MinFreq

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.15

Integer

RO

Reflectsthesubbanddefaultminimal
frequency.

winlink1000OduAirComboSubBand
MaxFreq

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.16

Integer

RO

Reflectsthesubbanddefaultmaximal
frequency.

winlink1000OduAirComboSubBand
FrequencyResolution

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.17

Integer

RO

Reflectsthesubbandfrequencyresolution.

winlink1000OduAirComboSubBand
DefaultChannelList

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.18

DisplayString

RO

Reflectsthedefaultchannellistvector.

winlink1000OduAirComboSubBand
DfsState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.19

Integer

RO

ReflectsthesubbandDFSstate.

winlink1000OduAirComboNumber
OfSubBands

1.3.6.1.4.1.4458.1000.1.5.5
3.2

Integer

RO

RepresentsthenumberofMultibandsub
bands.

winlink1000OduAirComboSwitchSu 1.3.6.1.4.1.4458.1000.1.5.5
bBand
3.3

DisplayString

RW Switchsubbandoperationwithagivensub
bandID.Thegetoperationretrievesthe
currentsubbandID.

winlink1000OduAirComboCurrentS
ubBandDesc

DisplayString

RO

CurrentSubBanddescription.

Integer

RO

MaxEthernetthroughputofthesite(inKpbs).

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.3

1.3.6.1.4.1.4458.1000.1.5.5
3.4

winlink1000OduAirInternalMaxRate 1.3.6.1.4.1.4458.1000.1.5.5
4

RADWIN5000HPMPUserManual

Release3.5.50

C16

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet12of33)
OID

Type

winlink1000OduAirCapacityDirectio
n

Access

Name

Description

RW Capacitydirectionofthesite.

winlink1000OduAirSpectrumAnalysi 1.3.6.1.4.1.4458.1000.1.5.5
sOperState
6.1

Integer

RW SpectrumAnalysisoperationstate.The
configurablevaluesareSpectrumAnalysisStop
StartandRestart.NotSupportedvalue
indicatesthatthefeatureisnotsupportedon
thedevice.NotSupportedisnota
configurablestate.

winlink1000OduAirRxPowerAntenn
aA

1.3.6.1.4.1.4458.1000.1.5.5
6.2

Integer

RO

ReceivedSignalStrengthindBmofAntennaA.

winlink1000OduAirRxPowerAntenn
aB

1.3.6.1.4.1.4458.1000.1.5.5
6.3

Integer

RO

ReceivedSignalStrengthindBmofAntennaB.

winlink1000OduAirNumberOfSpect 1.3.6.1.4.1.4458.1000.1.5.5
rumChannels
6.4

Integer

RO

RepresentsthenumberofSpectrumChannels.

winlink1000OduAirSpectrumChann
elTable

N/A ODUSpectrumAnalysisChannelTable.

winlink1000OduAirSpectrumChann
elTableEntry

N/A ODUSpectrumAnalysisChannelTableentry.
INDEX{
winlink1000OduAirSpectrumChannelIndex}

winlink1000OduAirSpectrumChann
elIndex

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.1

Integer

RO

ODUSpectrumChannelindex.

winlink1000OduAirSpectrumChann
elFrequency

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.2

Integer

RO

ODUSpectrumChannelfrequencyinMHz.

winlink1000OduAirSpectrumChann
elScanned

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.3

Integer

RO

Anindicationofthevaildityofthechannel's
data.Ifthechannelwasscannedthedatais
valid,elsenot.

winlink1000OduAirSpectrumChann
elScanningTimestamp

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.4

TimeTicks

RO

Channellastscantimestampinhundredthsofa
secondsincedeviceuptime.Ifthechannel
wasnotscannedthanthereturnvaluewillbe0.

winlink1000OduAirSpectrumChann
elLastNFAntennaA

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.5

Integer

RO

NormalizedNoiseFloorvalueindBmof
AntennaA(including2neighborfrequencies).

winlink1000OduAirSpectrumChann
elLastNFAntennaB

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.6

Integer

RO

NormalizedNoiseFloorvalueindBmof
AntennaB(including2neighborfrequencies).

winlink1000OduAirSpectrumChann
elAverageNFAntennaA

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.7

Integer

RO

AveragenormalizedNoiseFloorvalueindBm
ofAntennaAoveralldwells.

winlink1000OduAirSpectrumChann
elAverageNFAntennaB

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.8

Integer

RO

AveragenormalizedNoiseFloorvalueindBm
ofAntennaBoveralldwells.

winlink1000OduAirSpectrumChann
elMaxNFAntennaA

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.9

Integer

RO

MaxnormalizedNoiseFloorvalueindBmof
AntennaAoveralldwells.

winlink1000OduAirSpectrumChann
elMaxNFAntennaB

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.10

Integer

RO

MaxnormalizedNoiseFloorvalueindBmof
AntennaBoveralldwells.

winlink1000OduAirSpectrumChann
elCACPerformed

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.11

Integer

RO

WasCACperformedonthechannel.

winlink1000OduAirSpectrumChann
elLastCACTimestamp

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.12

TimeTicks

RO

LastCACperformedtimestampinhundredths
ofasecondsincedeviceuptime.IfnoCAChas
performedonthechannelthereturnvaluewill
be0.

winlink1000OduAirSpectrumChann
elRadarDetected

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.13

Integer

RO

WasRadardetectedonthechannel.

winlink1000OduAirSpectrumChann
elRadarDetectionTimestamp

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.14

TimeTicks

RO

LastRadarDetectiontimestampinhundredths
ofasecondsincedeviceuptime.IfnoRadar
hasdetectedonthechannelthereturnvalue
willbe0.

winlink1000OduAirSpectrumChann
elAvailable

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.15

Integer

RO

WasRadardetectedonthechannel.

winlink1000OduAirSpectrumChann
elMaxBeaconRss

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.16

Integer

RO

ThemaxRSSvalueofareceivedbeacononthe
specificchannelindBm.

RADWIN5000HPMPUserManual

Release3.5.50

C17

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet13of33)
Access

Name

OID

Type

winlink1000OduAirSpectrumChann
elCompressed

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.17

OctetString

RO

CompressalltheSpectrumdataperchannel
intoonevariable.Frequency(4bytes)
Scanned(1byte)Timestamp(4bytes)LastNF
AntennaA(1byte)LastNFAntennaB(1byte)
AvgNFAntennaA(1byte)AvgNFAntennaB(1
byte)MaxNFAntennaA(1byte)MaxNF
AntennaB(1byte)CACPerformed(1byte)
LastCACTimestamp(4bytes)RadarDetected
(1byte)RadarDetectedTimestamp(4bytes)
ChannelAvailable(1byte)MaxBeaconRSS(1
byte).

winlink1000OduAirChipMinMaxFre
q

1.3.6.1.4.1.4458.1000.1.5.5
6.6

DisplayString

RO

Theminimumandmaximumfrequenciesin
MHzwhichthechipsupports.

winlink1000OduAirSpectrumAnalysi
sTimeout

Description

RW Spectrumanalysistimeoutinseconds.

winlink1000OduAirAntConfAndRate 1.3.6.1.4.1.4458.1000.1.5.5
sStatus
7

Integer

RO

Description:AntennaconfigurationandRates
status(1=Singleantennawithsingledata
stream2=Dualantennawithsingledata
stream3=Dualantennawithdualdata
stream).

winlink1000OduAirDualAntTxMode 1.3.6.1.4.1.4458.1000.1.5.5
8

Integer

RW Description:TransmissiontypewhenusingDual
radios(MIMOorAdvancedDiversityusingone
streamofdata).

winlink1000OduAirTxOperationMo
de

1.3.6.1.4.1.4458.1000.1.5.5
9

Integer

RW ThisparametercontrolstheOperationmodeof
framessentovertheair.TheOperationmode
iseithernormal(1)forregulartransmission
whereframesizeisdeterminedbythetrafficor
throughputtest(2)whentheuserrequestsan
actualovertheairthroughputestimationusing
fullframes.Thelatterlastsnomorethana
predeterminedinterval(default30sec).

winlink1000OduAirDesiredNetMast 1.3.6.1.4.1.4458.1000.1.5.6
erTxRatio
0.1

Integer

RW Thisparameterisreservedtotheelement
managerprovidedwiththeproduct.

winlink1000OduAirCurrentNetMast 1.3.6.1.4.1.4458.1000.1.5.6
erTxRatio
0.2

Integer

RO

RepresentstheactualNetMasterTxRAtio.

winlink1000OduAirMinUsableMast
erTxRatio

1.3.6.1.4.1.4458.1000.1.5.6
0.3

Integer

RO

Representstheminimalvaluetheusercan
configureforDesirednetmAsterTxRatio.

winlink1000OduAirMaxUsableMast
erTxRatio

1.3.6.1.4.1.4458.1000.1.5.6
0.4

Integer

RO

Representsthemaximalvaluetheusercan
configureforDesirednetmAsterTxRatio.

winlink1000OduAirAccumulatedUA
S

1.3.6.1.4.1.4458.1000.1.5.6
1

Integer

RO

AccumulatestheUnavailablesecondsoftheAir
Interface.Relevantforpointtopointsystems.

winlink1000OduAirDistStr

1.3.6.1.4.1.4458.1000.1.5.6
2

DisplayString

RO

PossibilitiesofthelinkaccordingtoRFPand
CBW

winlink1000OduAirChannelsDefault 1.3.6.1.4.1.4458.1000.1.5.6
FreqStr
3

DisplayString

RO

Astringrepresentingthechannelsavailable.
Eachcharacterrepresentsonefrequencywhen
'1'meansitsavailableand'0'meansitsnot.

winlink1000OduAirAntConnectionT 1.3.6.1.4.1.4458.1000.1.5.6
ype
4

Integer

RW Antennaconnectiontype(External(1)
Integrated(2)Embedded_External(3)
Embedded_Integrated(4)EmbeddedBSA(5)).

winlink1000OduAirAllowableChann 1.3.6.1.4.1.4458.1000.1.5.6
elsStr
5

DisplayString

RW Astringrepresentingtheallowablechannels.
Eachcharacterrepresentsonechannelwhen'1'
meansitsavailableand'0'meansitsnot.

winlink1000OduAirDfsAlgorithmTyp 1.3.6.1.4.1.4458.1000.1.5.6
eState
6.1

Integer

RW BitmapforstateofRadarAlgorithmType.Filters
bybit'sposition:0=ZeroPW1=Fixed2=
Variable3=Staggered4=Long.

winlink1000OduAirDfsLastDetected
Tbl

N/A Lastdetectedradarstable.

winlink1000OduAirDfsLastDetected
Entry

N/A ODUMultibandSubBandsTableentry.INDEX
{winlink1000OduAirDfsLastDetectedIndex}

RADWIN5000HPMPUserManual

Release3.5.50

C18

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet14of33)
OID

Type

Access

Name

Description

winlink1000OduAirDfsLastDetected 1.3.6.1.4.1.4458.1000.1.5.6
Index
6.2.1.1

Integer

RO

DfsLastDetectedRadarsTableIndex.

winlink1000OduAirDfsLastDetected 1.3.6.1.4.1.4458.1000.1.5.6
Time
6.2.1.2

TimeTicks

RO

Dfstimeofthelastdetectedradar.

winlink1000OduAirDfsLastDetected 1.3.6.1.4.1.4458.1000.1.5.6
AlgorithmType
6.2.1.3

Integer

RO

Dfstypeofthelastdetectedradar.

winlink1000OduAirDfsLastDetected 1.3.6.1.4.1.4458.1000.1.5.6
Frequency
6.2.1.4

Integer

RO

Dfsfrequencyofthelastdetectedradar.

winlink1000OduAirPreferredChann
elsStr

RW Astringrepresentingthepreferredchannels.
Eachcharacterrepresentsonechannelwhen'1'
meansitspreferredand'0'meansitsnot.

winlink1000OduAirSyncLossThresh
old

RW Whenthecurrentthroughputisbelowthis
threshold(inKbps)synclosswilloccur.

winlink1000OduAirGeoLocation

1.3.6.1.4.1.4458.1000.1.5.6
9

winlink1000OduAirAggregateCapaci 1.3.6.1.4.1.4458.1000.1.5.7
ty
0

DisplayString

RW Geographicdevicelocationinformat:latitude
longitude.

Integer

RO

AggregateCapacityoftheODUinMbps.

winlink1000OduAirALPMDataBuffer
Str

RW AstringthatholdsalloftheALPMeventsdata

winlink1000OduAirCurrentManualA
ngle

RO

Absolute(manual)angle(Deg.)oftheunit.

winlink1000OduAirCurrentManualE
levAngle

RO

AbsoluteElevationangle(Deg.)oftheunit.

winlink1000OduPerfMonCurrTable

N/A Thistabledefines/keepsthecountersofthe
current15mininterval.

winlink1000OduPerfMonCurrEntry

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000OduPerfMonCurrUAS

1.3.6.1.4.1.4458.1000.1.6.1. Gauge
1.1

RO

ThecurrentnumberofUnavailableSeconds
startingfromthepresent15minutesperiod.

winlink1000OduPerfMonCurrES

1.3.6.1.4.1.4458.1000.1.6.1. Gauge
1.2

RO

CurrentnumberofErroredSecondsstarting
fromthepresent15minutesperiod.

winlink1000OduPerfMonCurrSES

1.3.6.1.4.1.4458.1000.1.6.1. Gauge
1.3

RO

CurrentnumberofSeverelyErroredSeconds
startingfromthepresent15minutesperiod.

winlink1000OduPerfMonCurrBBE

1.3.6.1.4.1.4458.1000.1.6.1. Gauge
1.4

RO

CurrentnumberofBackgroundBlockErrors
startingfromthepresent15minutesperiod.

winlink1000OduPerfMonCurrIntegri 1.3.6.1.4.1.4458.1000.1.6.1. Integer


ty
1.5

RO

Indicatestheintegrityoftheentry.

winlink1000OduPerfMonCurrComp 1.3.6.1.4.1.4458.1000.1.6.1. OctetString


ressed
1.6

RO

Holdsacompressedstringofalldataper
interface.CompressedAirInterfaceStructure
(sizeinbrackets):UAS(4)ES(4)SES(4)BBE
(4)Integrity(1)MinRSL(1)MaxRSL(1)
RSLThresh1Exceeded(4)RSLThresh2Exceeded
(4)MinTSL(1)MaxTSL(1)TSLThresh1Exceed
(4)BBERThresh1Exceed(4)RxMBytes(4)
TxMBytes(4)EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)Compressed
EtherentODUinterface(sizeinbrackets):UAS
(4)ES(4)SES(4)BBE(4)Integrity(1)
RxMBytes(4)TxMBytes(4)
EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)ActiveSeconds(4)

winlink1000OduPerfMonIntervalTa
ble

N/A Thistabledefines/keepsthecountersofthelast
day(inresolutionof15minintervals).

winlink1000OduPerfMonIntervalEn
try

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndexwinlink1000OduPerfMonIntervalIdx}

winlink1000OduPerfMonIntervalIdx

RO

RADWIN5000HPMPUserManual

Release3.5.50

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

C19

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet15of33)
OID

Type

Access

Name

Description

winlink1000OduPerfMonIntervalUA
S

RO

ThecurrentnumberofUnavailableSecondsper
interval.

winlink1000OduPerfMonIntervalES

RO

CurrentnumberofErroredSecondsperinterval.

winlink1000OduPerfMonIntervalSE
S

RO

CurrentnumberofSeverelyErroredSecondsper
interval.

winlink1000OduPerfMonIntervalBB
E

RO

CurrentnumberofBackgroundBlockErrorsper
interval.

winlink1000OduPerfMonIntervalInt
egrity

RO

Indicatestheintegrityoftheentryperinterval.

winlink1000OduPerfMonIntervalCo
mpressed

RO

Holdsacompressedstringofalldataper
interface.CompressedAirInterfaceStructure
(sizeinbrackets):UAS(4)ES(4)SES(4)BBE
(4)Integrity(1)MinRSL(1)MaxRSL(1)
RSLThresh1Exceeded(4)RSLThresh2Exceeded
(4)MinTSL(1)MaxTSL(1)TSLThresh1Exceed
(4)BBERThresh1Exceed(4)RxMBytes(4)
TxMBytes(4)EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)Compressed
EtherentODUinterface(sizeinbrackets):UAS
(4)ES(4)SES(4)BBE(4)Integrity(1)
RxMBytes(4)TxMBytes(4)
EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)ActiveSeconds(1)

winlink1000OduPerfMonDayTable

N/A Thistabledefines/keepsthecountersofthelast
month(inresolutionofdays).

winlink1000OduPerfMonDayEntry

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonDayIdx}

winlink1000OduPerfMonDayIdx

RO

Thistableisindexedperintervalnumber.Each
intervalisof24hoursandtheoldestis30.

winlink1000OduPerfMonDayUAS

RO

ThecurrentnumberofUnavailableSecondsper
intervalof24hours.

winlink1000OduPerfMonDayES

RO

CurrentnumberofErroredSecondsperinterval
of24hours.

winlink1000OduPerfMonDaySES

RO

CurrentnumberofSeverelyErroredSecondsper
intervalof24hours.

winlink1000OduPerfMonDayBBE

RO

CurrentnumberofBackgroundBlockErrorsper
intervalof24hours.

winlink1000OduPerfMonDayIntegri
ty

RO

Indicatestheintegrityoftheentryperinterval
of24hours.

winlink1000OduPerfMonDayCompr
essed

RO

Holdsacompressedstringofalldataper
interface.CompressedAirInterfaceStructure
(sizeinbrackets):UAS(4)ES(4)SES(4)BBE
(4)Integrity(1)MinRSL(1)MaxRSL(1)
RSLThresh1Exceeded(4)RSLThresh2Exceeded
(4)MinTSL(1)MaxTSL(1)TSLThresh1Exceed
(4)BBERThresh1Exceed(4)RxMBytes(4)
TxMBytes(4)EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)Compressed
EtherentODUinterface(sizeinbrackets):UAS
(4)ES(4)SES(4)BBE(4)Integrity(1)
RxMBytes(4)TxMBytes(4)
EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)ActiveSeconds(1)

winlink1000OduPerfMonAirCurrTab
le

N/A Thistabledefines/keepstheaircountersofthe
current15mininterval.

winlink1000OduPerfMonAirCurrEnt
ry

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000OduPerfMonAirCurrMi
nRSL

RO

RADWIN5000HPMPUserManual

Release3.5.50

CurrentMinReceivedLevelReferencestarting
fromthepresent15minutesperiod.

C20

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet16of33)
OID

Type

Access

Name

Description

winlink1000OduPerfMonAirCurrMa
xRSL

RO

CurrentMaxReceivedLevelReferencestarting
fromthepresent15minutesperiod.

winlink1000OduPerfMonAirCurrRSL
Thresh1Exceed

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL1thresholdinthelast15
minutes.

winlink1000OduPerfMonAirCurrRSL
Thresh2Exceed

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL2thresholdinthelast15
minutes.

winlink1000OduPerfMonAirCurrMi
nTSL

RO

CurrentMinTransmitSignalLevelstartingfrom
thepresent15minutesperiod.

winlink1000OduPerfMonAirCurrMa
xTSL

RO

CurrentMaxTransmitSignalLevelstartingfrom
thepresent15minutesperiod.

winlink1000OduPerfMonAirCurrTSL
Thresh1Exceed

RO

NumberofsecondsTransmitSignalLevel
exceededtheTSL1thresholdinthelast15
minutes.

winlink1000OduPerfMonAirCurrBB
ERThresh1Exceed

RO

NumberofsecondsBackgroundBlockError
RatioexceededtheBBER1thresholdinthelast
15minutes.

winlink1000OduPerfMonAirInterval
Table

N/A Thistabledefines/keepstheaircountersofthe
lastday(inresolutionof15minintervals).

winlink1000OduPerfMonAirInterval
Entry

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndexwinlink1000OduPerfMonAirIntervalIdx
}

winlink1000OduPerfMonAirInterval
Idx

RO

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonAirInterval
MinRSL

RO

CurrentMinReceivedLevelReferenceper
interval.

winlink1000OduPerfMonAirInterval
MaxRSL

RO

CurrentMaxReceivedLevelReferenceper
interval.

winlink1000OduPerfMonAirInterval
RSLThresh1Exceed

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL1thresholdperinterval.

winlink1000OduPerfMonAirInterval
RSLThresh2Exceed

NumberofsecondsReceiveSignalLevel
exceededtheRSL2thresholdACCESSreadonly
perinterval.

winlink1000OduPerfMonAirInterval
MinTSL

RO

CurrentMinTransmitSignalLevelperinterval.

winlink1000OduPerfMonAirInterval
MaxTSL

RO

CurrentMaxTransmitSignalLevelperinterval.

winlink1000OduPerfMonAirInterval
TSLThresh1Exceed

RO

NumberofsecondsTransmitSignalLevel
exceededtheTSL1thresholdperinterval.

winlink1000OduPerfMonAirInterval
BBERThresh1Exceed

RO

NumberofsecondsBackgroundBlockError
RatioexceededtheBBER1thresholdper
interval.

winlink1000OduPerfMonAirDayTabl
e

N/A Thistabledefines/keepstheaircountersofthe
lastmonth(inresolutionofdays).

winlink1000OduPerfMonAirDayEntr
y

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonAirDayIdx}

winlink1000OduPerfMonAirDayIdx

RO

ThistableisindexedperDaynumber.EachDay
isof15minutesandtheoldestis96.

winlink1000OduPerfMonAirDayMin
RSL

RO

CurrentMinReceivedLevelReferenceperDay.

winlink1000OduPerfMonAirDayMa
xRSL

RO

CurrentMaxReceivedLevelReferenceperDay.

winlink1000OduPerfMonAirDayRSL
Thresh1Exceed

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL1thresholdperDay.

RADWIN5000HPMPUserManual

Release3.5.50

C21

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet17of33)
OID

Type

Access

Name

Description

winlink1000OduPerfMonAirDayRSL
Thresh2Exceed

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL2thresholdperDay.

winlink1000OduPerfMonAirDayMin
TSL

RO

CurrentMinTransmitSignalLevelperDay.

winlink1000OduPerfMonAirDayMa
xTSL

RO

CurrentMaxTransmitSignalLevelperDay.

winlink1000OduPerfMonAirDayTSL
Thresh1Exceed

RO

NumberofsecondsTransmitSignalLevel
exceededtheTSL1thresholdperDay.

winlink1000OduPerfMonAirDayBBE
RThresh1Exceed

RO

NumberofsecondsBackgroundBlockError
RatioexceededtheBBER1thresholdperDay.

winlink1000OduPerfMonEthCurrTa
ble

N/A Thistabledefines/keepstheethernetcounters
ofthecurrent15mininterval.

winlink1000OduPerfMonEthCurrEn
try

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000OduPerfMonEthCurrRx
MBytes

RO

CurrentRXMegaBytesstartingfromthe
present15minutesperiod.

winlink1000OduPerfMonEthCurrTx
MBytes

RO

CurrentTransmitMegaBytesstartingfromthe
present15minutesperiod.

winlink1000OduPerfMonEthCurrEt
hCapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdinthepresent15minutesperiod.
Relevantforpointtopointsystems.

winlink1000OduPerfMonEthCurrHi
ghTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdinthepresent15minutesperiod.

winlink1000OduPerfMonEthCurrAc
tiveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
swervicewasnotblockedinthepresent15
minutesperiod.

winlink1000OduPerfMonEthInterva
lTable

N/A Thistabledefines/keepstheethernetcounters
ofthelastday(inresolutionof15minintervals).

winlink1000OduPerfMonEthInterva
lEntry

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndexwinlink1000OduPerfMonEthIntervalIdx
}

winlink1000OduPerfMonEthInterva
lIdx

RO

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonEthInterva
lRxMBytes

RO

CurrentRXMegaBytesperinterval.

winlink1000OduPerfMonEthInterva
lTxMBytes

RO

CurrentTransmitMegaBytesperinterval.

winlink1000OduPerfMonEthInterva
lEthCapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdintheeachinterval.Relevantfor
pointtopointsystems.

winlink1000OduPerfMonEthInterva
lHighTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdintheeachinterval.

winlink1000OduPerfMonEthInterva
lActiveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedintheeachinterval.

winlink1000OduPerfMonEthDayTab
le

N/A Thistabledefines/keepstheethernetcounters
ofthelastmonth(inresolutionofdays).

winlink1000OduPerfMonEthDayEnt
ry

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonEthDayIdx}

winlink1000OduPerfMonEthDayIdx

RO

ThistableisindexedperDaynumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonEthDayRx
MBytes

RO

CurrentRXMegaBytesperday.

winlink1000OduPerfMonEthDayTx
MBytes

RO

CurrentTransmitMegaBytesperday.

RADWIN5000HPMPUserManual

Release3.5.50

C22

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet18of33)
OID

Type

Access

Name

Description

winlink1000OduPerfMonEthDayEth
CapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdeachday.Relevantforpointtopoint
systems.

winlink1000OduPerfMonEthDayHig
hTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdeachday.

winlink1000OduPerfMonEthDayAct
iveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedeachday.

winlink1000OduPerfMonTdmCurrTa
ble

N/A Thistabledefines/keepstheTDMcountersof
thecurrent15mininterval.

winlink1000OduPerfMonTdmCurrE
ntry

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000OduPerfMonTdmCurrA
ctiveSeconds

RO

winlink1000OduPerfMonTdmInterv
alTable

N/A Thistabledefines/keepstheTDMcountersof
thelastday(inresolutionof15minintervals).

winlink1000OduPerfMonTdmInterv
alEntry

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndex
winlink1000OduPerfMonTdmIntervalIdx}

winlink1000OduPerfMonTdmInterv
alIdx

RO

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonTdmInterv
alActiveSeconds

RO

ParameterindicatingwhethertheTDMservice
wasactive.UnderTDMbackuplinkthe
parameterindicateswhetherthebackuplink
wasactive.

winlink1000OduPerfMonTdmDayTa
ble

N/A Thistabledefines/keepstheTDMcountersof
thelastmonth(inresolutionofdays).

winlink1000OduPerfMonTdmDayEn
try

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonTdmDayIdx}

winlink1000OduPerfMonTdmDayId
x

RO

ThistableisindexedperDaynumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonTdmDayAc
tiveSeconds

RO

ParameterindicatingwhethertheTDMservice
wasactive.UnderTDMbackuplinkthe
parameterindicateswhetherthebackuplink
wasactive.

winlink1000OduPerfMonTxThresh1

RW WhentheTransmitpowerexceedsthis
thresholdaperformancemonitoringTSL1
counterisincremented.

winlink1000OduPerfMonRxThresh1

RW WhentheRXpowerexceedsthisthresholda
performancemonitoringRSL1counteris
incremented.

winlink1000OduPerfMonRxThresh2

RW WhentheRXpowerexceedsthisthresholda
performancemonitoringRSL2counteris
incremented.

winlink1000OduPerfMonBBERThres
h1

RW WhentheBBERexceedsthisthresholda
performancemonitoringBBERcounteris
incremented.Theunitsare1/10ofapercent.

winlink1000OduPerfMonEthCapacit
yThreshKbps

RW Whenthecurrentthroughputisbelowthis
thresholdthecorrespondingcounteris
incremented

winlink1000OduPerfMonHighTraffic
ThreshKbps

RW Whenthecurrenttrafficisabovethisthreshold
thencorrespondingcounterisincremented.

winlink1000OduAgnGenAddTrapExt

RW If'yes'ischosentheifIndexUnitSeverity
Time_TandAlarmIdfromthe
winlink1000OduAgnCurrAlarmTablewillbe
bindtotheendofeachprivatetrap.

RADWIN5000HPMPUserManual

Release3.5.50

ParameterindicatingwhethertheTDMservice
wasactive.UnderTDMbackuplinkthe
parameterindicateswhetherthebackuplink
wasactive.

C23

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet19of33)
OID

Type

Access

Name

Description

winlink1000OduAgnGenSetMode

RW Thisparameterisreservedtotheelement
managerprovidedwiththeproduct.

winlink1000OduAgnGenLocalConne
ctionMode

RW LocalConnection(Broadcast)Configuration
Mode.Optionsare:1SNMPReadWrite2
SNMPReadOnly.

winlink1000OduAgnNTPCfgTimeSer
verIP

RW IPaddressoftheserverfromwhichthecurrent
timeisloaded.

winlink1000OduAgnNTPCfgTimeOff
setFromUTC

RW OffsetfromCoordinatedUniversalTime
(minutes).Possiblevalues:1440..1440.

winlink1000OduAgnRealTimeAndD
ate

RW Thisparameterspecifiestherealtimeanddate
Format'YYYYMMDDHH:MM:SS'
(Hexadecimal).Adatetimespecification:
fieldoctetscontentsrange
112year
0..6553623month1..12
34day1..3145hour
0..2356minutes0..596
7seconds0..60(use60
forleapsecond)78deciseconds
0..9ForexampleTuesdayMay261992
at1:30:15PMEDTwouldbedisplayedas:
07c8051a0d1e0f00(1992526
13:30:15)

winlink1000OduAdmNTPCfgTimeSe
rverIPv6

RW IPv6addressoftheserverfromwhichthe
currenttimeisloaded.

winlink1000OduAgnCurrAlarmLastC
hange

RO

winlink1000OduAgnCurrAlarmTable

N/A Thistableincludesthecurrentlyactivealarms.
WhenaRAISEDtrapissentanalarmentry
isaddedtothetable.WhenaCLEARtrapissent
theentryisremoved.

winlink1000OduAgnCurrAlarmEntry

N/A Entrycontainingthedetailsofacurrently
RAISEDtrap.INDEX{
winlink1000OduAgnCurrAlarmCounter}

winlink1000OduAgnCurrAlarmCoun
ter

RO

Arunningcounterofactivealarms.Thecounter
isincrementedforeverynewRAISEDtrap.Itis
clearedafteradevicereset.

winlink1000OduAgnCurrAlarmSeve
rity

RO

CurrentAlarmseverity.

winlink1000OduAgnCurrAlarmId

RO

UniqueAlarmIdentifier(combinesalarmtype
andinterface).ThesameAlarmIdisusedfor
RAISEDandCLEAREDalarms.

winlink1000OduAgnCurrAlarmIfInd
ex

RO

InterfaceIndexwherethealarmoccurred.
Alarmsthatarenotassociatedwithaspecific
interfacewillhavethefollowingvalue:65535.

winlink1000OduAgnCurrAlarmUnit

RO

Unitassociatedwiththealarm.

winlink1000OduAgnCurrAlarmTrapI
D

RO

IDoftheraisedtrapthatwassentwhenthis
alarmwasraised.

winlink1000OduAgnCurrAlarmTime
T

RO

Timestampofthisalarm.Thisnumberisin
secondsfromMidnightJanuary1st1970.

winlink1000OduAgnCurrAlarmText

RO

Alarmdisplaytext(sameasthetextinthesent
trap).

winlink1000OduAgnLastEventsNum
ber

RO

Thiscounterindicatesthesizeofthe
winlink1000OduAgnLastEventsTable

winlink1000OduAgnLastEventsTable

N/A Thistableincludesthelastevents.Whenatrap
issentanevententryisaddedtothetable.

RADWIN5000HPMPUserManual

Release3.5.50

Thiscounterisinitializedto0afteradevice
resetandisincrementeduponeachchangein
thewinlink1000OduAgnCurrAlarmTable(either
anadditionorremovalofanentry).

C24

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet20of33)
OID

Type

Access

Name

Description

winlink1000OduAgnLastEventsEntr
y

N/A Entrycontainingthedetailsoflasttraps.INDEX
{winlink1000OduAgnLastEventsIndex}

winlink1000OduAgnLastEventsInde
x

RO

Theindexofthetable

winlink1000OduAgnLastEventsSeve
rity

RO

CurrentTrapseverity.

winlink1000OduAgnLastEventsIfInd
ex

RO

InterfaceIndexwheretheeventoccurred.Traps
thatarenotassociatedwithaspecific
interfacewillhavethefollowingvalue:65535.

winlink1000OduAgnLastEventsTime
T

RO

Timestampofthistrap.Thisnumberisin
secondsfromMidnightJanuary1st1970.

winlink1000OduAgnLastEventsText

RO

Trapdisplaytext(sameasthetextinthesent
trap).

winlink1000OduAgnUsersTable

N/A SNMPuserstable.Eachuserisdefinedbyname
passwordandprofile.

winlink1000OduAgnUsersEntry

N/A SNMPuserstableentry.INDEX{
winlink1000OduAgnUsersIndex}

winlink1000OduAgnUsersIndex

RO

winlink1000OduAgnUsersUserNam
e

RW SNMPusersusernames.

winlink1000OduAgnUsersPassword

RW SNMPuserspasswords.

winlink1000OduAgnUsersProfile

RW SNMPusersprofile(1=Disabled2=ReadOnly
3=ReadWrite).

winlink1000OduAgnUsersLastAcces
sTime

RO

SNMPuserslastaccesstime.

winlink1000IduAdmProductType

RO

IDUconfigurationdescription.

winlink1000IduAdmHwRev

RO

IDUHardwareRevision.

winlink1000IduAdmSwRev

RO

IDUSoftwareRevision.

winlink1000OduAdmNumOfExterna
lAlarmIn

RO

Indicatesthenumberofcurrentlyavailable
ExternalAlarmInputs.

winlink1000OduAdmExternAlarmIn
Table

N/A ThisistheExternalAlarmInputstable.

winlink1000OduAdmExternAlarmIn
Entry

N/A Entrycontainingtheelementsofasingle
ExternalAlarmInput.INDEX{
winlink1000OduAdmExternAlarmInIndex}

winlink1000OduAdmExternAlarmIn
Index

RO

winlink1000OduAdmExternAlarmIn
Text

RW ThisfielddescribestheExternalAlarmInput.It
isanoptionalstringofnomorethan64
characterswhichwillbeusedintheevent
beingsentasaresultofachangeinthestatusof
theExternalAlarmInput.DEFVAL{Alarm
Description}

winlink1000OduAdmExternAlarmIn
AdminState

RW ThisvalueindicatesifthisExternalAlarmInput
isenabledordisabled.

winlink1000OduAdmExternAlarmIn
Status

RO

Thisvalueindicatesthecurrentstatusofthe
ExternalAlarmInput.

winlink1000IduAdmSN

RO

IDUSerialNumber

winlink1000IduAdmIduDetectionM
ode

RW Theparameterdefineswhethertosend
EthernetframestodetectanIDU.Thevalid
writablevaluesare:userDisabled(3)
userEnabled(4).Achangerequiresaresetand
iseffectiveafterreset.

winlink1000IduAdmMountedTrunks

RO

NumberofmountedtrunksintheIDU

winlink1000IduAdmLicensedTrunks

RO

NumberofLicensedTrunksintheIDU

RADWIN5000HPMPUserManual

Release3.5.50

SNMPuserstableindex.

ThisvalueindicatestheindexoftheExternal
AlarmInputentry.

C25

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet21of33)
OID

Type

Access

Name

Description

winlink1000IduAdmVlanSupported

RO

winlink1000IduAdmVlanEgressMod
e

RW VLANtag/untagegressvalues

winlink1000IduAdmVlanIngressMo
de

RW VLANtag/untagingressvalues

winlink1000IduAdmVlanDefaultPor
tVIDs

RW VLANtag/untagdefaultVLANidsforeachport
RightmostdigitisVlanpriority(06)otherdigits
composeVlanId(14094)

winlink1000IduAdmVlanLan1Untag
gedVIDs

RW VLANuntaggedVIDsforLAN1port

winlink1000IduAdmVlanLan2Untag
gedVIDs

RW VLANuntaggedVIDsforLAN2port

winlink1000IduAdmVlanSfpUntagg
edVIDs

RW VLANuntaggedVIDsforSfpport

winlink1000IduAdmVlanLan1Filtere
dVIDs

RW VLANfilteredVIDsforLAN1port

winlink1000IduAdmVlanLan2Filtere
dVIDs

RW VLANfilteredVIDsforLAN2port

winlink1000IduAdmVlanSfpFiltered
VIDs

RW VLANfilteredVIDsforSfpport

winlink1000IduAdmPortsConnectio
n

RW IDUportsconnectionbitmap.bit0LAN1
LAN2bit1SFPLAN1bit2SFPLAN2bit
values:0portsaredisconnected.1ports
areconnected.

winlink1000IduAdmVlanMode

RW LocalIDUVlanMode.

winlink1000IduAdmVlanMembersh
ipVIDs

RW VLANMembershipVLANIDslist.

winlink1000IduAdmVlanMembersh
ipPortsCode

RW VLANMembershipportscode.Eachvalue
representtherelation(bitmap)Betweenthe
suitableVIDtotheIDUports.bit0LAN1bit
1LAN2bit2SFPbitvalue0notmember
ofappropriateVIDbitvalue1memberof
appropriateVID

winlink1000IduAdmVlanMembersh
ipUntaggedHandle

RW VLANMembershipUntaggedframeshandling.
The3valuesrepresentingLAN1LAN2andSFP
accordingly.Foreachporttheoptionalvalues
are:1Discard2Tag3LeaveUnmodified

winlink1000IduAdmVlanMembersh
ipTagUntagged

RW VLANMembershipUntaggedframestagging.
The3valuesrepresentingLAN1LAN2andSFP
accordingly.Thevalueoneachportentry
representthetaggingvaluewhichisbuiltof:
VLANID&VLANPriority.

winlink1000IduSrvDesiredTrunks

RW Requiredtrunksbitmap.Notethatthenumber
ofpossibletrunksthatcanbeconfiguredmay
varybasedontheIDUhardwareconfiguration
theselectedairinterfacerateandtherangeof
theinstallation.TheprovidedManager
applicationenablestheusertoselectonly
availableconfigurations.Achangeiseffective
immediatelyifappliedtoamasterunitandthe
linkisinservicemode.

winlink1000IduSrvServices

RO

ThisparameterisreservedtotheManager
applicationprovidedwiththeproduct.

winlink1000IduSrvActiveTrunks

RO

AbitmapdescribingthecurrentlyopenTDM
trunks.

RADWIN5000HPMPUserManual

Release3.5.50

IdentifiesifthelocalIDUsupportsVLANtag/
untag

C26

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet22of33)
OID

Type

Access

Name

Description

winlink1000IduSrvAvailableTrunks

RO

winlink1000IduSrvPossibleServices
Table

N/A IDUPossibleServicestable.

winlink1000IduSrvPossibleServices
Entry

N/A IDUServicestableentry.INDEX{
winlink1000IduSrvPossibleServicesIndex}

winlink1000IduSrvPossibleServicesI
ndex

RO

TableindexRateindexoftheairinterface.

winlink1000IduSrvPossibleTdmServi
ces

RO

Deprecatedparameter.Abitmapdescribingthe
TDMtrunksthatcanbeopenedinthe
correspondingAirRate.

winlink1000IduSrvPossibleEthServic
es

RO

Deprecatedparameter.Thisparameter
describesiftheEthernetServicecanbeopened
inthecorrespondingAirRate.Thevalidvalues
are:disabled(0)enabled(1).

winlink1000IduSrvRemainingRate

RO

CurrentEthernetbandwidthinbpsperairrate.

winlink1000IduSrvTrunkCost

RO

CostoftheTDMServiceinbps.

winlink1000IduSrvAvailServicesTabl
e

N/A ODUPossibleTDMServicestable.

winlink1000IduSrvAvailServicesEntr
y

N/A ODUTDMServicestableentry.INDEX{
winlink1000IduSrvAvailServicesIndex}

winlink1000IduSrvAvailServicesInde
x

RO

Tableindex.Theindexisthebitmaskofthe
TDMservice.

winlink1000IduSrvAvailServicesStat
e

RO

RepresentstheTDMserviceavailability.

winlink1000IduSrvAvailServicesMin
RateIdx

RO

Minimumrateindexoftheairinterfacewhich
maketheservicepossible.

winlink1000IduSrvAvailServicesMax
RateIdx

RO

Maximumrateindexoftheairinterfacewhich
maketheservicepossible.

winlink1000IduSrvAvailServicesRea
son

RO

InformationabouttheTDMServiceavailability.
NotApplicableiftheserviceisavailable.The
reasonsforTDMServiceunavailability:The
availablethroughputisn'tsufficientforService
demands;TheIDUHWdoesn'tsupportthe
service;ALinkPasswordmismatchwas
detected;Theexternalpulsetypedetectedis
improperforTDMservices;ASoftware
versionsmismatchwasdetected.ASymetric
TDDModeIsObligated.

winlink1000IduSrvEthActive

RO

RepresentstheEthernetserviceactivationstate.

winlink1000IduSrvEthAvailable

RO

RepresentstheEthernetserviceavailability
state.

winlink1000IduSrvEthThroughput

RO

CurrentavailableEthernetservicethroughputin
bps.

winlink1000IduSrvEthMaxInfoRate

RW Holdsthemaximumbandwidth(kbps)tobe
allocatedforEthernetservice.Valueofzero
meansthatEthernetserviceworksasbest
effort.Themaximumvalueisproductspecific.
Refertotheusermanual.

winlink1000IduSrvAvailableTrunksT
1

RO

RADWIN5000HPMPUserManual

Release3.5.50

AbitmapdescribingthenumberofTDMtrunks
thatcanbeopenedinthecurrentconfiguration.
ThevaluestakeintoaccounttheIDUhardware
configurationtheairrateandtheinstallation
range.

AbitmapdescribingtheTDMtrunksthatcanbe
openedunderT1configuration.Thevalues
takeintoaccounttheIDUhardware
configurationtheairrateandtheinstallation
range.

C27

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet23of33)
OID

Type

Access

Name

Description

winlink1000IduEthernetIfTable

N/A IDUEthernetInterfacetable.

winlink1000IduEthernetIfEntry

N/A IDUEthernetInterfacetableentry.INDEX{
winlink1000IduEthernetIfIndex}

winlink1000IduEthernetIfIndex

RO

IfIndexcorrespondingtothisInterface.

winlink1000IduEthernetIfAddress

RO

IDUMACaddress.

winlink1000IduEthernetNumOfLan
Ports

RO

NumberofLANinterfacesintheIDU.

winlink1000IduEthernetNumOfSfpP
orts

RO

ThenumberofSFPinterfacesintheIDU.

winlink1000IduEthernetSfpProperti
es

RO

SFPvenforproperties:VendorNamePNand
Revision.

winlink1000IduEthernetGbeSuppor
ted

RO

SupportedGigabitEthernetinIDU.

winlink1000IduEthernetOduInError
s

RO

Thenumberofinboundpacketsthatcontained
errorspreventingthemfrombeingdeliverable
toahigherlayerprotocol.

winlink1000IduBridgeTpAging

RW Timeoutinsecondsforaging.Notethatforthis
parametertobeeffectivetheODUmustbe
configuredtoHUBmode.Achangeiseffective
immediately.

winlink1000IduTdmTxClockAvailStat
es

RO

winlink1000IduTdmTxClockDesiredS
tate

RW RequiredstateoftheTDMTransmitClock
Control.Achangeiseffectiveafterreactivation
oftheTDMservice.

winlink1000IduTdmTxClockActualSt
ate

RO

ActualstateoftheTDMTransmitClockControl.

winlink1000IduTdmMasterClockAva
ilOptions

RO

AvailableoptionsoftheTDMMasterClock
Controleachinputstatusisrepresentedbya
bit.Whentheoptionisavailablethebitvalue
is1.Whentheoptionisunavailablethebit
valueis0.Theavailableoptionsare:bit2=
Automaticbit3=Trunk#1bit4=Trunk#2bit
5=Trunk#3bit6=Trunk#4Whennooptions
areavailablethereturnedvalueis:1

winlink1000IduTdmMasterClockDes
ired

RW RequiredTDMMasterClock.Achangeis
effectiveafterreactivationoftheTDMservice.

winlink1000IduTdmMasterClockAct
ual

RO

winlink1000IduTdmConfigTable

N/A IDUTDMLinksConfigurationtable.

winlink1000IduTdmConfigEntry

N/A IDUTDMLinksConfigurationtableentry.
INDEX{winlink1000IduTdmConfigIndex}

winlink1000IduTdmConfigIndex

RO

Tableindex.

winlink1000IduTdmIfIndex

RO

Linkindexintheinterfacetable.

winlink1000IduTdmLineCoding

RW ThisparameterappliestoT1trunksonly.The
parametercontrolsthelinecoding.Settingthe
valuetoeachoftheindicesappliestoall.A
changeiseffectiveafterthenextopenofthe
TDMservice.

RADWIN5000HPMPUserManual

Release3.5.50

AvailablestatesoftheTDMTransmitClock
Controleachinputstatusisrepresentedbya
bit.Whenthestateisavailablethebitvalueis
1.Whenthestateisunavailablethebitvalue
is0.Theavailablestatesare:bit2=
Transparentbit3=LocalLoopTimedbit4=
RemoteLoopTimedbit5=LocalInternalbit6
=RemoteInternal

ActualTrunkusedforTDMMasterClock.

C28

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet24of33)
OID

Type

Access

Name

Description

winlink1000IduTdmLoopbackConfig

RW Loopbackconfigurationtable.Eachofthe
trunkscanbesetNormalLineloopbackor
Reverselineloopback.Achangeiseffective
immediately.

winlink1000IduTdmLineStatus

RO

winlink1000IduTdmCurrentTable

N/A IDUTDMLinksStatisticstable.

winlink1000IduTdmCurrentEntry

N/A IDUTDMLinksStatisticstableentry.INDEX{
winlink1000IduTdmCurrentIndex}

winlink1000IduTdmCurrentIndex

RO

Tableindex(Sameas
winlink1000IduTdmLineIndex).

winlink1000IduTdmCurrentBlocks

RO

Numberofcorrectblockstransmittedtothe
line.

winlink1000IduTdmCurrentDrops

RO

Numberoferrorblockstransmittedtotheline.

winlink1000IduTdmCurrentTxClock

RW TDMTransmitClock.Achangeiseffectiveafter
reactivationoftheTDMservice.

winlink1000IduTdmCurrentBlocksHi
gh

RO

Highpartofthe64bitscounterCurrentBlocks

winlink1000IduTdmRemoteQual

RO

Estimatedaverageintervalbetweenerror
secondevents.Thevalidvaluesare12^31
whereavalueof1isusedtoindicatean
undefinedstate.

winlink1000IduTdmRemoteQualEva
l

RO

Estimatedaverageintervalbetweenerror
secondeventsduringevaluationprocess.The
validvaluesare12^31whereavalueof1is
usedtoindicateanundefinedstate.

winlink1000IduTdmSrvEval

RW EvaluatedTDMservicebitmask.Settingthis
parametertovaluethatisbiggerthanthe
activatedTDMservicebitmaskwillexecute
theevaluationprocessfor30seconds.Setting
thisparameterto0willstoptheevaluation
processimmediately.

winlink1000IduTdmBackupAvailabl
eLinks

RO

winlink1000IduTdmBackupTable

N/A IDUTDMLinksStatisticstable.

winlink1000IduTdmBackupEntry

N/A IDUTDMLinksStatisticstableentry.INDEX{
winlink1000IduTdmBackupIndex}

winlink1000IduTdmBackupIndex

RO

winlink1000IduTdmBackupMode

RW TDMbackupmode:EnableorDisablewhere
themainlinkistheairlinkortheexternallink.
Changeswillbeeffectiveimmediatly.

winlink1000IduTdmBackupCurrentA
ctiveLink

RO

winlink1000IduTdmJitterBufferSize

RW TDMJitterBufferSize.Thevaluemustbe
betweentheminimumandthemaximumTDM
JitterBufferSize.Theunitsare0.1x
millisecond.

winlink1000IduTdmJitterBufferDefa
ultSize

RO

TDMJitterBufferDefaultSize.Theunitsare0.1
xmillisecond.

winlink1000IduTdmJitterBufferMinS
ize

RO

TDMJitterBufferMinimumSize.Theunitsare
0.1xmillisecond.

winlink1000IduTdmJitterBufferMax
Size

RO

TDMJitterBufferMaximumSize.Theunitsare
0.1xmillisecond.

winlink1000IduTdmJitterBufferSizeE
val

RW TDMJitterBufferSizeforevaluation.The
valuemustbebetweentheminimumandthe
maximumTDMJitterBufferSize.Theunitsare
0.1xmillisecond.

RADWIN5000HPMPUserManual

Release3.5.50

Linestatus.

NumberofTDMbackuptrunks.

Tableindex.

TDMbackupcurrentactivelink:N/Aairlinkis
activeorexternallinkisactive.

C29

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet25of33)
OID

Type

Access

Name

Description

winlink1000IduTdmType

RW TDMType(Thevalueundefinedisreadonly).

winlink1000IduTdmTypeEval

RW TDMTypeforevaluation.

winlink1000IduTdmLineStatusStr

RO

Linestatus.

winlink1000IduTdmHotStandbySup
port

RO

IndicatesifHotStandbyissupported.

winlink1000IduTdmDesiredHotStan
dbyMode

RW DesiredHotStandbyMode.

winlink1000IduTdmHotStandbyOpe
rationStatus

RO

winlink1000IduTdmBackupLinkConf
iguration

RW Thecurrentconfigurationofthebackuplink.

winlink1000IduTdmLineInterfaceCo
nfiguration

RW TDMLineinterfaceconfiguration.

winlink1000IduTdmLineImpedance
Configuration

RW TDMlineimpedanceconfiguration(standardT1
100OhmnonStandardT1110Ohm)
ApplicableonlyforT1TDMtype.

winlink1000HbsAirState

RO

winlink1000HbsAirOpMode

RW HoldstheoperationmodeoftheHBS.

winlink1000HbsAirAvailTimeSlots

RO

Thisparameterholdsthenumberofavailable
timeslots(notinuse)intheairinterface.

winlink1000HbsAirSectorCbwSuppo
rtedStr

RO

Representsthechannelbandwidthwhichis
supportedbytheHBSandallconnectedHSUs.

winlink1000HbsAirCompressedMon

RO

HoldsHBSmonitordataincompressedformat:
HBSTrafficMonitorInBytes(4)OutBytes(4)
InFrames(4)OutFrames(4)HBSState(1)HBS
Freq(4)NumberofLinks(2)ECChange
Counter(4)CurrentRatio(2)TotalAirFrames
(4)HBSRxRateinKbps(4)HBSTxRateinKbps
(4)HBSRxRateinFps(4)HBSTxRateinFps
(4)HBSSetMode(1).

winlink1000HbsAirConfChanges

RO

16charactersthatrepresent16HSUs.Each
timeaconfigurationisbeenchangedincrement
therelevantcharacter.

winlink1000HbsAirConfTable

N/A HoldsthetableforallregisteredHSUsinthe
sector(16entries).

winlink1000HbsAirConfEntry

N/A HSUsconfigurationtableentry.INDEX{
winlink1000HbsAirConfIndex}

winlink1000HbsAirConfIndex

RO

winlink1000HbsAirConfUpMir

RW UplinkMIRtowardsspecificHSUinunitsof
kbps.

winlink1000HbsAirConfDownMir

RW DownlinkMIRtowardsspecificHSUinunitsof
kbps.

winlink1000HbsAirConfHsuName

RW HSUname.

winlink1000HbsAirConfHsuLocation

RW HSUlocation.

winlink1000HbsAirConfDualAntTxM
ode

RW TransmissiontypewhenusingDualAntennaon
bothlink'ssides.spatialMultiplexingDiversity
(usingasinglespatialstream)andAuto
Selection(OMScontrol).

winlink1000HbsAirConfNumOfTs

RW Numberoftimeslotwhichareallocatedto
specificHSU.

winlink1000HbsAirConfGeoLocatio
n

RW Geographicdevicelocationinformat:latitude
longitude.

winlink1000HbsAirConfHsuType

RW HSUtype(1=Fixed2=Stationary3=Mobile4
=Transport)

winlink1000HbsAirConfHsuLevel

RW HSUlevel(1..4)

RADWIN5000HPMPUserManual

Release3.5.50

TheLinkActualStatus.

HoldsthestateoftheHBS.

HSUsconfigurationtableindex.

C30

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet26of33)
OID

Type

Access

Name

Description

winlink1000HbsAirConfDesiredRate
Index

RW Therateindexofbothsidesofthelinktothis
HSU.

winlink1000HbsAirConfMacAddress

RO

winlink1000HbsAirConfNumOfTsUp

RW NumberofULtimeslotwhichareallocatedto
specificHSU.

winlink1000HbsAirLinkNumOfLinks

RO

winlink1000HbsAirLinkTable

N/A Holdsthetableforalllinksinthesector.

winlink1000HbsAirLinkEntry

N/A Linktableentry.INDEX{
winlink1000HbsAirLinkIndex}

winlink1000HbsAirLinkIndex

RO

HSUsconfigurationtableindex.

winlink1000HbsAirLinkHsuId

RO

HSUIDofspecificlink(ifregistered).
Unregisteredlinkshave1.

winlink1000HbsAirLinkState

RO

Holdsthestateofspecificlink.

winlink1000HbsAirLinkWorkingMod
e

RO

Indicatesthesubstatewithintheversion
compatibility.

winlink1000HbsAirLinkSessionId

RO

HoldstheSessionIDofthelink.

winlink1000HbsAirLinkHbsEstTput

RO

HoldstheEstimatedthroughputfromtheHBS
totheHSU.

winlink1000HbsAirLinkHsuEstTput

RO

HoldstheEstimatedthroughputfromtheHSU
totheHBS.

winlink1000HbsAirLinkRange

RO

Holdstherangeofspecificlink.

winlink1000HbsAirLinkHbsRss

RO

HoldstheRSSofspecificlink(HBSside).

winlink1000HbsAirLinkHbsRssBal

RO

HoldstheRSSBalanceofspecificlink(HBSside).
2:Radio2RSSismuchstrongerthanRadio1
RSS.1:Radio2RSSisstrongerthanRadio1
RSS.0:Radio2RSSisequaltoRadio1RSS.1
:Radio1RSSisstrongerthanRadio2RSS.2:
Radio1RSSismuchstrongerthanRadio2RSS.

winlink1000HbsAirLinkHsuRss

RO

HoldstheRSSofspecificlink(HSUside).

winlink1000HbsAirLinkHsuRssBal

RO

HoldstheRSSBalanceofspecificlink(HSUside).
2:Radio2RSSismuchstrongerthanRadio1
RSS.1:Radio2RSSisstrongerthanRadio1
RSS.0:Radio2RSSisequaltoRadio1RSS.1
:Radio1RSSisstrongerthanRadio2RSS.2:
Radio1RSSismuchstrongerthanRadio2RSS.

winlink1000HbsAirLinkHsuSerial

RO

HoldstheserialnumberforspecificHSU.

winlink1000HbsAirLinkTxOperMode

RO

HoldstheTXoperationmode.

winlink1000HbsAirHsuInBytes

RO

NumberofframesreceivedintheHSULanport.

winlink1000HbsAirHsuOutBytes

RO

NumberofframestransmittedfromtheHSU
Lanport.

winlink1000HbsAirHsuInFrames

RO

NumberofbytesreceivedintheHSULanport.

winlink1000HbsAirHsuOutFrames

RO

NumberofbytestransmittedfromtheHSULan
port.

winlink1000HbsAirHsuMacAddress

RO

HSUMACAddress.

winlink1000HbsAirMaxTputDown

RO

MaxThroughputDownlink.

winlink1000HbsAirMaxTputUp

RO

MaxThroughputUplink.

RADWIN5000HPMPUserManual

Release3.5.50

HSUMACAddress.

Numberoflinksinthelinkstable.

C31

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet27of33)
OID

Type

Access

Name

Description

winlink1000HbsAirLinkCompressed
Mon

RO

Holdsallthelinkinformationincompressed
binary(Bytes/octets).Fieldsincluded(sizein
bytes):LinkState(1)LinkWorking
Mode(1)SessionId(4)HBSEst.
Tput(4)HSUEst.Tput(4)HBSRss(1)
HBSRssBalance(1)HSURss(1)HSU
RssBalance(1)TxOperationMode(1)
HSUInBytes(4)HSUOutBytes(4)
HSUInFrames(4)HSUOutFrames(4)
HSUID(1bytes)HSURxRateInKbps(4)HSU
TxRateInKbps(4)HSURxRateInFps(4)HSU
TxRateInFps(4)PeakthroughputintheDL
direction(4)PeakthroughputintheUL
direction(4)Numberoflocalchangesat
HSU(1)ReservedforSmallCellSystems(1)HBS
Chain1Rss(1)HBSChain2Rss(1)HBSChain3
Rss(1)HSUChain1Rss(1)HSUChain2Rss(1)
HSUChain3Rss(1)CurrentRateIndex(2).

winlink1000HbsAirLinkCompressed
Static

RO

Holdsalltheconfigurationdataofthislinkin
compressedformat.HelpstheNMStogetinfo
regardingnewUnregisteredlinks.Fields
Included:SessionID(4bytes)HSUIPaddress
(4bytes)HSUName(32bytes)HSULocation
(32bytes)HSUSerialnumber(16bytes)HSU
MACAddress(12bytes)AirLinkRangeMax
ThroughputDown(4bytes)MaxThroughput
Up.(4bytes)CpacityLimit(4bytes)HSU
Antennatype(1byte)AggregateCapacity(4
bytes)

winlink1000HbsAirCpeCapacityLimi
t

RO

CapacityLimitinKilobitpersecond.

winlink1000HbsAirLinkAntennaTyp
e

RO

HSUExternalAntennaType:Monopolaror
Bipolar.

winlink1000HbsAirHsuRxRateInKbp
s

RO

HSURxRateinKbps.

winlink1000HbsAirHsuTxRateInKbp
s

RO

HSUTxRateinKbps.

winlink1000HbsAirHsuRxRateInFps

RO

HSUTxRateinFps.

winlink1000HbsAirHsuTxRateInFps

RO

HSUTxRateinFps.

winlink1000HbsAirLinkPeakTputDo
wn

RO

PeakthroughputintheDLdirection(kbps).

winlink1000HbsAirLinkPeakTputUp

RO

PeakthroughputintheULdirection(kbps).

winlink1000HbsAirLinkUtilDownSec
RelMill

RO

Theaveragetimepercentage(inthousandths)
outoftheBTSDLcapabilitythatwasusedfor
transmittingdatatotheSU.

winlink1000HbsAirLinkUtilUpSecRel
Mill

RO

Theaveragetimepercentage(inthousandths)
outoftheBTSULcapabilitythatwasusedfor
receivingdatafromtheSU.

winlink1000HbsAirLinkUtilDownAll
ocRelMill

RO

Thetimepercentage(inthousandths)relative
totheSUDLallocationthatwasusedfor
transmittingdatatotheSU.

winlink1000HbsAirLinkUtilUpAllocR
elMill

RO

Thetimepercentage(inthousandths)relative
totheSUULallocationthatwasusedfor
receivingdatafromtheSU.

winlink1000HbsAirLinkUtilDownTra
fficKbps

RO

Averagedatathroughput(ExportedinKbps)
transmittedintheDLtowardstheSUduring
thelastsecond.

RADWIN5000HPMPUserManual

Release3.5.50

C32

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet28of33)
OID

Type

Access

Name

Description

winlink1000HbsAirLinkUtilUpTraffic
Kbps

RO

Averagedatathroughput(ExportedinKbps)
receivedintheULfromtheSUduringthelast
second.

winlink1000HbsAirLinkUtilCompres
sedMon

RO

Onestringthatholdsthe6Utilizationperlink
values:DownSecRel(2bytes)UpSecRel
(2bytes)DownAllocRel(4bytes)UpAllocRel
(4bytes)DownTraffic(4bytes)UpTraffic(4
bytes).

winlink1000HbsAirComboSwitchSec
torFreqBandId

RW SwitchFrequencybandforthewholesector.

winlink1000HbsAirGeoAzimuth

RW Geographicsectorazimuthindegrees*10.

winlink1000HbsAirGeoBeamwidth

RW Geographicsectorbeamwidthindegrees*10.

winlink1000HbsAirMaxDistanceMet
ersMobility

RW Maximumdistanceinmeters.UsedbyMobility
linksonly.

winlink1000HbsAirComboSwitchSec
torFreqBandIdStr

RW SwitchFrequencybandforthewholesector
overridingsomeoftheComboparameters.

winlink1000HbsAirTimeSlotAllocati
onBitmap

RW TimeSlotsAllocationBitmapfortheentire
sector(HexValue).

winlink1000HbsAirAvailTimeSlotsU
p

RO

Thisparameterholdsthenumberofavailable
ULtimeslots(notinuse)intheairinterface.

winlink1000HbsAirDownUtilMill

RO

SectorAirInterfaceutilizationintheDownlink
direction(thousandths).Averagetime
percentageoutoftheentireBTSDLcapability
thatwasusedfortransmittingdatatoallthe
SUs.

winlink1000HbsAirUpUtilMill

RO

SectorAirInterfaceutilizationintheUplink
direction(thousandths).Theaveragenumber
oftimeslotsthatwereusedintheUL(byallthe
links)outoftheentirenumberoftimeslots.

winlink1000HbsAirDownTrafficKbps

RO

Averagedatathroughput(expressedinKbps)
transmittedintheDLtowardsalltheSUs
duringthelastsecond.

winlink1000HbsAirUpTrafficKbps

RO

Averagedatathroughput(expressedinKbps)
receivedintheULfromalltheSUsduringthe
lastsecond.

winlink1000HbsAirCompressedMon
Sec

RO

Onestringthatholdsthe4UtilizationperSector
values:DownUtil(2bytes)UpUtil(2bytes)
DownTraffic(4bytes)UpTraffic(4bytes).

winlink1000HbsAirDelayVsTputOpt

RW Delayvs.Throughputoptimizationtype:1=
Delaysensitivity2=Throughputoptimized

winlink1000HbsAirUCBPMinCS

RW MinimalcontentionslotlengthusedforUCBP
algorithm(inms.)between520ms.

winlink1000HbsAirUCBPSharingPer
centage

RW SharingpercentageusedbyUCBPalgorithm(15
75)

winlink1000HbsBridgeAgingTime

RW Timeoutinsecondsforaging.

winlink1000HbsBridgeVlanTable

N/A HoldsthebridgeVlanoperationstowardsallthe
registeredHSUs.

winlink1000HbsBridgeVlanEntry

N/A HBSbridgeVlantableentry.INDEX{
winlink1000HbsBridgeVlanIndex}

winlink1000HbsBridgeVlanIndex

RO

winlink1000HbsBridgeVlanIngress

RW HBSbridgeVlaningress.

winlink1000HbsBridgeVlanEgress

RW HBSbridgeVlanegress.

winlink1000HbsBridgeVlanFilterIn

RW HBSbridgeVlanfilterin.

winlink1000HbsBridgeVlanFilterOut

RW HBSbridgeVlanfilterout.

winlink1000HbsBridgeVlanDoubleT
ag

RW HBSbridgeVlandoubletag.

RADWIN5000HPMPUserManual

Release3.5.50

HBSbridgeVlantableindex.

C33

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet29of33)
OID

Type

Access

Name

Description

winlink1000HbsBridgeVlanDefaultI
d

RW HBSbridgeVlandefaultid.

winlink1000HbsBridgeMembership
Table

N/A Holdsthebridgemembershiprelationsforall
theregisteredHSUs.

winlink1000HbsBridgeMembership
Entry

N/A HBSbridgemembershiptableentry.INDEX{
winlink1000HbsBridgeMembershipIndex}

winlink1000HbsBridgeMembershipI
ndex

RO

winlink1000HbsBridgeMembership
State

RW HBSbridgemembershipstatebitmap.Eachbit
representsBlocked/Openedrelation
(membership)betweentwoHSUs.Blocked=0
(bit)Opened=1(bit).Thisobjectholdsthe
relationto32HSUs.

winlink1000HbsBridgeMembership
State2nd

RW HBSbridgemembershipstatebitmap.Eachbit
representsBlocked/Openedrelation
(membership)betweenHSUandLAN/Stackport
oftheHBS.Blocked=0(bit)Opened=1(bit).
Only2bitsareused.

winlink1000HbsBridgeFloodOverloa
dProtect

RW Floodoverloadprotection1Enabled2
Disabled.

winlink1000HbsServiceCommandSt
r

RW AbilitytoperformspecialcommandintheHBS.
Format(string):OperationIndexSession
Param1Param2....|ParamNTheindexand
SessionIDcanbeunitingtooneparameter.On
registeredHSUitisHSUIDandonUnregistered
itisSessionID.

winlink1000HbsServiceVlanTable

N/A HoldstheVlanoperationstowardsallthe
registeredHSUs.

winlink1000HbsServiceVlanEntry

N/A HBSserviceVlantableentry.INDEX{
winlink1000HbsServiceVlanIndex}

winlink1000HbsServiceVlanIndex

RO

winlink1000OduServiceVlanTblTag

RW TheVIDtobeusedwhenaddingTAGoradding
Provider

winlink1000OduServiceVlanTblPri

RW TheVlanpriority07tobeusedwhenadding
TAGoraddingProvider

winlink1000OduServiceVlanTblMaj
orMode

RW TheVlanmajormode

winlink1000OduServiceVlanTblEgre
ssMode

RW TheVlanmodeintheEgressdirection

winlink1000OduServiceVlanTblIngr
essMode

RW TheVlanmodeintheIngressdirection

winlink1000OduServiceVlanTblEgre
ssFilter1

RW VLANFilter1VID

winlink1000OduServiceVlanTblEgre
ssFilter2

RW VLANFilter2VID

winlink1000OduServiceVlanTblEgre
ssFilter3

RW VLANFilter3VID

winlink1000OduServiceVlanTblEgre
ssFilter4

RW VLANFilter4VID

winlink1000OduServiceVlanTblUnta
gFilteredBitmap

RW Represents(inbitmap)iftoUntagaframeafter
itisfiltered(Egressdirection)[4bitsrepresent4
filters].

winlink1000OduServiceVlanTblProv
iderTPID

RW HoldstheProviderTPIDthatisusedinall
provideroperations.

winlink1000HbsServiceQoSMode

RW QualityofServicemode.

RADWIN5000HPMPUserManual

Release3.5.50

HBSbridgemembershiptableindex.

HBSserviceVlantableindex.

C34

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet30of33)
OID

Type

Access

Name

Description

winlink1000HbsServiceQoSVlanQGr
oupsStr

RW FrameclassificationaccordingtoVLANpriority
(all4groupsseparatedbycomma).

winlink1000HbsServiceQoSDiffserv
QGroupsStr

RW FrameclassificationaccordingtoDiffserv(all4
groupsseparatedbycomma).

winlink1000HbsServiceQoSMaxRtQ
uePct

RO

winlink1000HbsServiceQoSTable

N/A HoldstheQoSoperationstowardsallthe
registeredHSUs.

winlink1000HbsServiceQoSEntry

N/A HBSserviceQoStableentry.INDEX{
winlink1000HbsServiceQoSIndex}

winlink1000HbsServiceQoSIndex

RO

winlink1000HbsServiceQoSConfAd
minState

RW QoSadministrativestate.Thevalidvaluesare:
enabled(1)disabled(2).

winlink1000HbsServiceQoSConfUp
QueMir

RW PrivateMIRforeachQoSgroupoftheUplink
direction(4valuesseparatedbycomma).

winlink1000HbsServiceQoSConfUp
QueWeight

RW WeightinpercentforeachQoSgroupofthe
Uplinkdirection(4valuesseparatedbycomma).

winlink1000HbsServiceQoSConfDo
wnQueMir

RW PrivateMIRforeachQoSgroupoftheDownlink
direction(4valuesseparatedbycomma).

winlink1000HbsServiceQoSConfDo
wnQueWeight

RW WeightinpercentforeachQoSgroupofthe
Downlinkdirection(4valuesseparatedby
comma).

winlink1000HbsServiceQoSUpTtlMs

RW TTLinmilisecondforeachQoSgroupofthe
Uplinkdirection(4valuesseparatedbycomma).

winlink1000HbsServiceQoSDownTtl
Ms

RW TTLinmilisecondforeachQoSgroupofthe
Downlinkdirection(4valuesseparatedby
comma).

winlink1000HbsServiceQoSUpStrict

RW StrictQOSBooleanindicationforeachQOS
groupoftheUplinkdirection(4values
separatedbycomma).

winlink1000HbsServiceQoSDownStr
ict

RW StrictQOSBooleanindicationforeachQOS
groupoftheDownlinkdirection(4values
separatedbycomma).

winlink1000HbsServiceMobilitySup
ported

RO

MobilitySupport(1=Notsupported2=
Supported3Transportsupported)

winlink1000HbsServiceMaxNumOf
HSUs

RO

HoldsthemaximumnumberofregisteredHSUs
intheHBS.

winlink1000HbsPerfMonThreshTabl
e

N/A Holdstheperformancemonitorthresholds
towardsalltheregisteredHSUs.

winlink1000HbsPerfMonThreshEntr
y

N/A HBSperformancemonitorthresholdtableentry.
INDEX{winlink1000HbsPerfMonThreshIndex}

winlink1000HbsPerfMonThreshInde
x

RO

winlink1000HbsPerfMonTxThresh1

RW HBSperformancemonitortransmitpower
threshold.

winlink1000HbsPerfMonRxThresh1

RW HBSperformancemonitorreceivepower
threshold1.

winlink1000HbsPerfMonRxThresh2

RW HBSperformancemonitorreceivepower
threshold2.

winlink1000HbsPerfMonBBERThres
h1

RW HBSperformancemonitorBBERthreshold.

winlink1000HbsPerfMonEstThroug
hputThreshKbps

RW HBSperformancemonitorestimated
throughputThreshold.

winlink1000HbsPerfMonHighTraffic
ThreshKbps

RW HBSperformancemonitorhightrafficthreshold.

RADWIN5000HPMPUserManual

Release3.5.50

MaximalpercentforRTandNRTqueues.

HBSserviceQoStableindex.

HBSperformancemonitorthresholdtable
index.

C35

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet31of33)
OID

Type

Access

Name

Description

winlink1000HbsPerfMonAirGenCur
rTable

N/A Thistabledefines/keepstheethernetcounters
ofthecurrent15mininterval.

winlink1000HbsPerfMonAirGenCur
rEntry

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000HbsPerfMonAirGenCur
rRxMBytes

RO

CurrentRXMegaBytesstartingfromthe
present15minutesperiod.(Representsthe
LANtrafficRXdirectiontowardtheHSU)

winlink1000HbsPerfMonAirGenCur
rTxMBytes

RO

CurrentTransmitMegaBytesstartingfromthe
present15minutesperiod.(Representsthe
LANtrafficTXdirectionfromtheHSU)

winlink1000HbsPerfMonAirGenCur
rEthCapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdinthepresent15minutesperiod.
Relevantforpointtopointsystems.

winlink1000HbsPerfMonAirGenCur
rHighTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdinthepresent15minutesperiod.

winlink1000HbsPerfMonAirGenCur
rActiveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
swervicewasnotblockedinthepresent15
minutesperiod.

winlink1000HbsPerfMonAirGenInte
rvalTable

N/A Thistabledefines/keepstheethernetcounters
ofthelastday(inresolutionof15minintervals).

winlink1000HbsPerfMonAirGenInte
rvalEntry

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndex
winlink1000HbsPerfMonAirGenIntervalIdx}

winlink1000HbsPerfMonAirGenInte
rvalIdx

RO

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000HbsPerfMonAirGenInte
rvalRxMBytes

RO

CurrentRXMegaBytesperinterval.
(RepresentstheLANtrafficRXdirectiontoward
theHSU).

winlink1000HbsPerfMonAirGenInte
rvalTxMBytes

RO

CurrentTransmitMegaBytesperinterval.
(RepresentstheLANtrafficTXdirectionfrom
theHSU)

winlink1000HbsPerfMonAirGenInte
rvalEthCapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdintheeachinterval.Relevantfor
pointtopointsystems.

winlink1000HbsPerfMonAirGenInte
rvalHighTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdintheeachinterval.

winlink1000HbsPerfMonAirGenInte
rvalActiveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedintheeachinterval.

winlink1000HbsPerfMonAirGenDay
Table

N/A Thistabledefines/keepstheethernetcounters
ofthelastmonth(inresolutionofdays).

winlink1000HbsPerfMonAirGenDay
Entry

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000HbsPerfMonAirGenDayIdx
}

winlink1000HbsPerfMonAirGenDay
Idx

RO

ThistableisindexedperDaynumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000HbsPerfMonAirGenDay
RxMBytes

RO

CurrentRXMegaBytesperday.(Represents
theLANtrafficRXdirectiontowardtheHSU)

winlink1000HbsPerfMonAirGenDay
TxMBytes

RO

CurrentTransmitMegaBytesperday.
(RepresentstheLANtrafficTXdirectionfrom
theHSU)

winlink1000HbsPerfMonAirGenDay
EthCapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdeachday.Relevantforpointtopoint
systems.

winlink1000HbsPerfMonAirGenDay
HighTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdeachday.

winlink1000HbsPerfMonAirGenDay
ActiveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedeachday.

RADWIN5000HPMPUserManual

Release3.5.50

C36

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet32of33)
OID

Type

Access

Name

Description

winlink1000HsuAirState

RO

HoldsthestateoftheHSU.

winlink1000HsuAirLinkState

RO

HoldsthestateoftheHSUlink.

winlink1000HsuAirHsuId

RO

HoldstheHSUIDassentbytheHBS.

winlink1000HsuAirLocalDeregister

RW PerformsLocalHSUDeregistrationwhenonly
whenthelinkisoff.

winlink1000HsuAirRemoteCompres
sedMon

RO

HoldsalltheconfigurationdataofTheHBSin
compressedformat.FieldsIncluded:Rss(1
byte)RssBalance(1byte)Est.Tput(4
bytes)InBytesofthewholesector(4bytes)
OutBytesofthewholesector(4bytes)In
Framesofthewholesector(4bytes)Out
Framesofthewholesector(4bytes)Max
ThroughputDownLink(4bytes)Max
ThroughputUpLink(4bytes)RxRateInKbpsof
thewholesector(4bytes)TxRateInKbpsof
thewholesector(4bytes)RxRateInFpsofthe
wholesector(4bytes)TxRateInFpsofthe
wholesector(4bytes)PeakThroughputinthe
DLdirectioninKbps(4bytes)PeakThroughput
intheULdirectioninKbps(4bytes)TxRatio(2
bytes)Chain1Rss(1byte)Chain2Rss(1byte)
Chain3Rss(1byte)CurrentRateIndex(2bytes)

winlink1000HsuAirRemoteCompres
sedStatic

RO

HoldsalltheconfigurationdataoftheHBSina
compressedformat.HelpstheNMStogetinfo
regardingnewUnregisteredlinks.Fields
Included:Location(32bytes)IPaddress(8
bytesinhexa)Subnetmask(8bytesinhexa)
HBSAntennatype(1byte)HBSAgentVersion
(4bytes)HBSName(32bytes)

winlink1000HsuAirRssThreshSync

RW HSUswillbesychnornizedimmediatelyifRSSis
betterthanthreshold.

winlink1000HsuAirAlignmentCmd

RW 1StartAlignmentprocessandinitializetheGIRO
2Evaluatecurrentmanualangle3Finish
Alignmentprocess4AbortAlignmentprocess

winlink1000HsuAirAlignmentStatus

RO

AntennaAlignmentstatus:1N/A(fornonBSA
products)1ISS(scanningforHBS)2CSA
(SynctoHBSwaitingforEvaluationcommand)
3Bidirectionallink4Evaluate2x25
Evaluate3x36AlignmentFinished.

winlink1000HsuAirAlignment3x3Ste
p

RO

StepnumberoutoftotalstepsinThroughput
evaluationfor3x3scenario.

winlink1000HsuAirAlignment3x3Tot
alSteps

RO

TotalstepsinThroughputevaluationfor3x3
scenario.

winlink1000HsuAirAlignmentEvalTo

RW Evaluationtimeout.

winlink1000HsuAirAlignmentLastRe
portManualAngle

RO

Theangleoftheantenna.Usedinthealignment
process.

winlink1000HsuAirAlignmentLastRe
portTputUpSector

RO

Expectedthroughputforthewholesectorinthe
Uplinkdirectioninthisangle.

winlink1000HsuAirAlignmentLastRe
portTputDownSector

RO

Expectedthroughputforthewholesectorinthe
Downlinkdirectioninthisangle.

winlink1000HsuAirAlignmentLastRe
portRssChain1

RO

RSSonchain1.

winlink1000HsuAirAlignmentLastRe
portRssChain2

RO

RSSonchain2.

winlink1000HsuAirAlignmentLastRe
portRssChain3

RO

RSSonchain3.

winlink1000HsuAirAlignmentLastRe
portMcsIndexUp

RO

MCSindexofthelinkintheuplinkdirection.

RADWIN5000HPMPUserManual

Release3.5.50

C37

PrivateMIBParameters

TableC2:PrivateMIBParametersHBS(Sheet33of33)
OID

Type

Access

Name

Description

winlink1000HsuAirAlignmentLastRe
portMcsIndexDown

RO

MCSindexofthelinkinthedownlinkdirection.

winlink1000HsuAirAlignmentLastRe
portState

RO

StateoftheEvaluation1Finishedsuccessfully
2PartialEvaluation(TimeoutExceeded)3
EvaluationAborted(TimeoutExceeded)4
Evaluationaborted(UnstableAntenna)5
Evaluationaborted(SyncLost)6Evaluation
aborted(Externalcommand)7Evaluating.

winlink1000HsuServiceCommandSt
r

RW AbilitytoperformspecialcommandintheHSU.
Format(string):OperationParam1Param2....|
ParamN.

winlink1000HsuServiceHsuType

RW HSUtype(1=Fixed2=Stationary3=Mobile4
=Transport)

winlink1000HsuServiceHsuLevel

RW HSUlevel(1..4)

winlink1000HsuEthernetPoESuppor
ted

RO

IndicatedifthisHSUhasspecialportforPoE
devices.

winlink1000HsuEthernetPoETempe
rature

RO

Holdsthetemperature(Celsius)ofthePOE
component.

winlink1000HsuEthernetPoEEquCo
nsumption

RO

Holdstheconsumptionoftheconnected
equipment(milliampere).

winlink1000HsuEthernetPoEEquVol
tage

RO

Holdsthevoltageoftheconnectedequipment
(Volt).

winlink1000GeneralTrapDescription 1.3.6.1.4.1.4458.1000.100.1 DisplayString

RO

Trap'sDescription.UsedforTrapparameters.

winlink1000GeneralTrapSeverity

1.3.6.1.4.1.4458.1000.100.2 Integer

RO

Trap'sSeverity.UsedforTrapparameters.

winlink1000GeneralCookie

1.3.6.1.4.1.4458.1000.100.3 DisplayString

RW ReservedfortheManagerapplicationprovided
withtheproductusedforsavinguser
preferencesaffectingODUoperation.

winlink1000GeneralEcChangesCoun 1.3.6.1.4.1.4458.1000.100.4 Integer


ter

RO

winlink1000GeneralTelnetSupport

1.3.6.1.4.1.4458.1000.100.5 Integer

RW Enable/DisableTelnetprotocol.

winlink1000GeneralWISupport

1.3.6.1.4.1.4458.1000.100.6 Integer

RW Enable/DisableWebInterfaceprotocol.
MandatoryDisabledNooptiontoenablethe
feature.MandatoryEnabledNooptionto
disablethefeature.

winlink1000GeneralSNMPSupport

1.3.6.1.4.1.4458.1000.100.7 Integer

RW Enable/DisableSNMPprotocols

RADWIN5000HPMPUserManual

Release3.5.50

Thiscounterisinitializedto0afteradevice
resetandisincrementeduponeachelement
constantwriteoperationviaSNMPorTelnet.

C38

PrivateMIBParameters

HSU
TableC3:PrivateMIBParametersHSU(Sheet1of33)
Access

Name

OID

Type

Description

winlink1000OduAdmProductType

1.3.6.1.4.1.4458.1000.1.1.1

DisplayString

RO

ODUconfigurationdescription.

winlink1000OduAdmHwRev

1.3.6.1.4.1.4458.1000.1.1.2

DisplayString

RO

ODUHardwareVersion.

winlink1000OduAdmSwRev

1.3.6.1.4.1.4458.1000.1.1.3

DisplayString

RO

ODUSoftwareVersion.

winlink1000OduAdmLinkName

1.3.6.1.4.1.4458.1000.1.1.4

DisplayString

RW LinkName.Achangeiseffectiveimmediately.

winlink1000OduAdmResetCmd

1.3.6.1.4.1.4458.1000.1.1.5

Integer

RW ResetCommand.Asetcommandwithavalue
of3willcauseadevicereset.HBSonly:Aset
commandwithavalueof4willcauseadevice
resetfortheentiresector.Thereadvalueis
always0.

winlink1000OduAdmAddres

1.3.6.1.4.1.4458.1000.1.1.6

IPAddress

RW ODUIPaddress.Achangeiseffectiveafterreset.
Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.

winlink1000OduAdmMask

1.3.6.1.4.1.4458.1000.1.1.7

IPAddress

RW ODUSubnetMask.Achangeiseffectiveafter
reset.Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.

winlink1000OduAdmGateway

1.3.6.1.4.1.4458.1000.1.1.8

IPAddress

RW ODUdefaultgateway.Achangeiseffectiveafter
reset.Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.

winlink1000OduAdmBroadcast

1.3.6.1.4.1.4458.1000.1.1.1
0

Integer

RW ThisparameterisreservedfortheManager
applicationprovidedwiththeproduct.

winlink1000OduAdmHostsTable

N/A Trapdestinationstable.Eachtrapdestinationis
definedbyanIPaddressandaUDPport.Upto
10addressescanbeconfigured.

winlink1000OduAdmHostsEntry

N/A Trapdestinationstableentry.INDEX{
winlink1000OduAdmHostsIndex}

winlink1000OduAdmHostsIndex

1.3.6.1.4.1.4458.1000.1.1.1
2.1.1

Integer

RO

winlink1000OduAdmHostsIp

1.3.6.1.4.1.4458.1000.1.1.1
2.1.2

IPAddress

RW TrapdestinationIPaddress.Achangeiseffective
immediately.

winlink1000OduAdmHostsPort

1.3.6.1.4.1.4458.1000.1.1.1
2.1.3

Integer

RW UDPportofthetrapdestination.Achangeis
effectiveimmediately.

winlink1000OduAdmHostsSecurity
Model

1.3.6.1.4.1.4458.1000.1.1.1
2.1.4

Integer

RW Securitymodelusedforthistrapgeneration.

winlink1000OduAdmHostsUserNam 1.3.6.1.4.1.4458.1000.1.1.1
e
2.1.5

DisplayString

RW Usernameusedtogeneratethesnmpv3trap.

winlink1000OduAdmHostsPasswor
d

1.3.6.1.4.1.4458.1000.1.1.1
2.1.6

DisplayString

RW Passwordusedtogeneratethesnmpv3trap.

winlink1000OduAdmHostsIPv6

1.3.6.1.4.1.4458.1000.1.1.1
2.1.7

DisplayString

RW TrapdestinationIPv6address.Achangeis
effectiveimmediately.

winlink1000OduBuzzerAdminState

1.3.6.1.4.1.4458.1000.1.1.1
3

Integer

RW Thisparametercontrolstheactivationofthe
buzzerwhiletheunitisininstallmode.A
changeiseffectiveimmediately.Thevalidvalues
are:disabled(0)enabledAuto(1)
enabledConstantly(2)advancedAuto(3).

winlink1000OduProductId

1.3.6.1.4.1.4458.1000.1.1.1
4

DisplayString

RO

RADWIN5000HPMPUserManual

Release3.5.50

Trapdestinationstableindex.

ThisparameterisreservedfortheManager
applicationprovidedwiththeproduct.

C39

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet2of33)
Access

Name

OID

Type

winlink1000OduReadCommunity

1.3.6.1.4.1.4458.1000.1.1.1
5

DisplayString

RW ReadCommunityString.Thisparameteralways
returns*****whenretrievingitsvalue.Itis
usedbytheManagerapplicationtochangethe
ReadCommunityString.TheSNMPagent
acceptsonlyencryptedvalues.

winlink1000OduReadWriteCommu
nity

1.3.6.1.4.1.4458.1000.1.1.1
6

DisplayString

RW Read/WriteCommunityString.Thisparameter
alwaysreturns*****whenretrievingitsvalue.
ItisusedbytheManagerapplicationtochange
theRead/WriteCommunityString.TheSNMP
agentacceptsonlyencryptedvalues.

winlink1000OduTrapCommunity

1.3.6.1.4.1.4458.1000.1.1.1
7

DisplayString

RW TrapCommunityString.Thisparameterisused
bytheManagerapplicationtochangetheTrap
CommunityString.TheSNMPagentaccepts
onlyencryptedvalues.

winlink1000OduAdmSnmpAgentVe
rsion

1.3.6.1.4.1.4458.1000.1.1.1
8

Integer

RO

MajorversionoftheSNMPagent.

winlink1000OduAdmRemoteSiteNa 1.3.6.1.4.1.4458.1000.1.1.1
me
9

DisplayString

RO

Remotesitename.Returnsthesamevalueas
sysLocationparameteroftheremotesite.

winlink1000OduAdmSnmpAgentMi 1.3.6.1.4.1.4458.1000.1.1.2
norVersion
0

Integer

RO

MinorversionoftheSNMPagent.

winlink1000OduAdmLinkPassword

1.3.6.1.4.1.4458.1000.1.1.2
1

DisplayString

RW LinkPassword.Thisparameteralwaysreturns
*****whenretrievingitsvalue.Itisusedby
theManagerapplicationtochangetheLink
Password.TheSNMPagentacceptsonly
encryptedvalues.

winlink1000OduAdmSiteLinkPassw
ord

1.3.6.1.4.1.4458.1000.1.1.2
2

DisplayString

RW SiteLinkPassword.Thisparameteralways
returns*****whenretrievingitsvalue.Itis
usedbytheManagerapplicationtochangethe
LinkPasswordofthesite.TheSNMPagent
acceptsonlyencryptedvalues.

winlink1000OduAdmDefaultPasswo 1.3.6.1.4.1.4458.1000.1.1.2
rd
3

Integer

RO

ThisparameterindicatesifthecurrentLink
Passwordisthedefaultpassword.

winlink1000OduAdmConnectionTy
pe

1.3.6.1.4.1.4458.1000.1.1.2
4

Integer

RO

ThisparameterindicatesiftheManager
applicationisconnectedtothelocalODUorto
theremoteODUovertheair.Avalueof
'unknown'indicatescommunitystring
mismatch.

winlink1000OduAdmBackToFactory 1.3.6.1.4.1.4458.1000.1.1.2
SettingsCmd
5

Integer

RW BacktofactorysettingsCommand.Achangeis
effectiveafterreset.Thereadvalueisalways
0.

winlink1000OduAdmIpParamsCnfg

1.3.6.1.4.1.4458.1000.1.1.2
6

DisplayString

RW ODUIPaddressConfiguration.Theformatis:
<IP_Address>|<Subnet_Mask>|<Default_Gatew
ay>|

winlink1000OduAdmVlanID

1.3.6.1.4.1.4458.1000.1.1.2
7

Integer

RW VLANID.Validvaluesare1to4094.Initialvalue
is0meaningVLANunaware.

winlink1000OduAdmVlanPriority

1.3.6.1.4.1.4458.1000.1.1.2
8

Integer

RW VLANPriority.0islowestpriority7ishighest
priority.

winlink1000OduAdmSN

1.3.6.1.4.1.4458.1000.1.1.2
9

DisplayString

RO

ODUSerialNumber

winlink1000OduAdmProductName

1.3.6.1.4.1.4458.1000.1.1.3
0

DisplayString

RO

ThisistheproductnameasitexistsatEC

winlink1000OduAdmActivationKey

1.3.6.1.4.1.4458.1000.1.1.3
1

DisplayString

RW Activatesageneralkey.

winlink1000OduAdmRmtPermitted
OduType

1.3.6.1.4.1.4458.1000.1.1.3
2

DisplayString

RW MobileApplication:permittedpartnerOduType.

winlink1000OduAdmCpuID

1.3.6.1.4.1.4458.1000.1.1.3
3

Integer

RO

RADWIN5000HPMPUserManual

Release3.5.50

Description

CPUID

C40

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet3of33)
Access

Name

OID

Type

Description

winlink1000OduAdmOvrdCmd

1.3.6.1.4.1.4458.1000.1.1.3
4

DisplayString

RW AbilitytoperformspecialcommandintheODU.

winlink1000OduAdmLinkMode

1.3.6.1.4.1.4458.1000.1.1.3
5

Integer

RW UnitPMPoperationmode.

winlink1000OduAdmActualConnect 1.3.6.1.4.1.4458.1000.1.1.3
Mode
6

Integer

RO

Unitconnectedasparttoptporptmp.

winlink1000OduAdmAES256Suppor 1.3.6.1.4.1.4458.1000.1.1.3
t
7

Integer

RO

AES256securitysupportindication.

winlink1000OduAdmAES256State

1.3.6.1.4.1.4458.1000.1.1.3
8

Integer

RW Enable/DisableAES256securitymodeoverthe
airlink.

winlink1000OduAdmAES256Status

1.3.6.1.4.1.4458.1000.1.1.3
9

Integer

RO

winlink1000OduAdmBatterySavingS 1.3.6.1.4.1.4458.1000.1.1.4
hutdownTime
0

Integer

RW BatterySavingShutdownTimeinminutes0till
batteryrunout1ifnotsupported.

winlink1000OduAdmWiFiPowerMo 1.3.6.1.4.1.4458.1000.1.1.4
de
1

Integer

RW WIFIunitpowermode.

winlink1000OduAdmShutdownTim
er

1.3.6.1.4.1.4458.1000.1.1.4
2

Integer

RO

ShutdownTimerinseconds.

winlink1000OduAdmGPSState

1.3.6.1.4.1.4458.1000.1.1.4
3

Integer

RO

GPSstate

winlink1000OduAdmTemperatureC

1.3.6.1.4.1.4458.1000.1.1.4
4

Integer

RO

Thetemperature(Celsius)insidetheBoard.

winlink1000OduAdmIPStackMode

1.3.6.1.4.1.4458.1000.1.1.4
5

Integer

RW TheIPstackmode.

winlink1000OduAdmIPv6ParamsCnf 1.3.6.1.4.1.4458.1000.1.1.4
g
6

DisplayString

RW ODUIPv6addressConfiguration.Theformatis:
<IP_Address>|<Subnet_Mask>|<Default_Gatew
ay>|

winlink1000OduAdmIPv6Address

1.3.6.1.4.1.4458.1000.1.1.4
7

DisplayString

RO

ODUIPv6address.

winlink1000OduAdmIPv6Prefix

1.3.6.1.4.1.4458.1000.1.1.4
8

Integer

RO

ODUIPv6subnetmask.

winlink1000OduAdmIPv6DefaultGa 1.3.6.1.4.1.4458.1000.1.1.4
teWay
9

DisplayString

RO

ODUIPv6defaultgateway.

winlink1000OduSrvMode

1.3.6.1.4.1.4458.1000.1.2.1

Integer

RW Systemmode.Theonlyvaluesthatcanbeset
areinstallModeandslaveMode;normalMode
reservedtotheManagerapplicationprovided
withtheproduct.Achangeiseffectiveafter
linkresynchronization.

winlink1000OduSrvBridging

1.3.6.1.4.1.4458.1000.1.2.3

Integer

RO

AES256operatingstatus

BridgingMode.Validvaluesare:disabled(0)
enabled(1).

winlink1000OduSrvRingLinkMode

RW Modeofthelinkregardingringtopology.

winlink1000OduSrvRingTopologySu
pported

RO

winlink1000OduSrvRingVlanIdTable

N/A RingVLANIDstable.

winlink1000OduSrvRingVlanIdEntry

N/A VLANIDoftheinternalringmessages.Valid
valuesare1to4094.Initialvalueis0meaning
VLANunaware.INDEX{
winlink1000OduSrvRingVlanIdIndex}

winlink1000OduSrvRingVlanIdIndex

RO

winlink1000OduSrvRingVlanId

RW VLANIDoftheinternalringmessages.Valid
valuesare1to4094.Initialvalueis0meaning
VLANunaware.

winlink1000OduSrvRingEthStatus

RO

winlink1000OduSrvRingMaxAllowe
dTimeFromLastRpm

RW Definestheminimaltime(inms)requiredfor
determinationofringfailure.

RADWIN5000HPMPUserManual

Release3.5.50

RingTopologyoptionsare:supportednot
supported

IndexofVLANIDoftheinternalringmessages.

RepresentstheEthernetserviceblockingstate
ofaRingslink

C41

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet4of33)
OID

Type

Access

Name

Description

winlink1000OduSrvRingWTR

RW Definestheminimaltime(inms)requiredfor
ringrecovery.

winlink1000OduSrvQoSMode

RW ModeofQoSfeature.

winlink1000OduSrvQoSConfTable

N/A QoSconfigurationtable.

winlink1000OduSrvQoSConfEntry

N/A QoSconfigurationtable.INDEX{
winlink1000OduSrvQoSConfIndex}

winlink1000OduSrvQoSConfIndex

RO

IndexofQoSConfiguration.

winlink1000OduSrvConfVlanQGrou
ps

RO

FramesclassificationaccordingtoVLANPriority
IDs.

winlink1000OduSrvConfDiffservQGr
oups

RO

FramesclassificationaccordingtoDiffserv.

winlink1000OduSrvConfQueMir

RW DesiredPrivateMIR.

winlink1000OduSrvConfQueWeight

RW QoSqueueu'sweightsinpercent.

winlink1000OduSrvQoSVlanQGroup
sSetStr

RW FramesclassificationaccordingtoVLANIDs
stringforset.

winlink1000OduSrvQoSDiffservQGr
oupsSetStr

RW FramesclassificationaccordingtoDiffservIDs
stringforset.

winlink1000OduSrvQoSMaxRTQueP
ercent

RO

MaximalpercentforRT&NRTqueues.

winlink1000OduSrvVlanSupport

RO

ODUEthernetportVLANsupportand
configurationavailabilityindication.1ODU
VLANFunctionalityNotSupported2ODU
VLANFunctionalitySupported3ODUVLAN
FunctionalitySupportedandAvailable

winlink1000OduSrvVlanIngressMod
e

RW ODUEthernetportingressVLANmode.

winlink1000OduSrvVlanEgressMod
e

RW ODUEthernetportegressVLANmode.

winlink1000OduSrvEgressTag

RW ODUethernetportegressVLANtag.Right
mostdigitisVlanpriority(07)otherdigits
composeVlanId(24094)

winlink1000OduSrvEgressProviderT
ag

RW ODUethernetportegressProviderVLANtag.
RightmostdigitisVlanpriority(07)other
digitscomposeVlanId(24094)

winlink1000OduSrvVlanIngressAllo
wedVIDs

RW ODUethernetportVLANIDsthatwillnotbe
filteredoningress.w|w|w|w|w|w|w|w|(
wherew={04094}andw!=1)

winlink1000OduSrvVlanDisable

RW DisableVLANfunctionality.Thefollowingvalues
canbeset:3DisableODU&IDUVLAN
Configurations.

winlink1000OduServiceVlanProvide
rListTPIDstr

RO

HoldsthepossibleProviderTPIDs.

RO

CurrentEthernetbandwidthinbps.

winlink1000OduEthernetRemaining 1.3.6.1.4.1.4458.1000.1.3.1
Rate

Integer

winlink1000OduEthernetIfTable

N/A ODUEthernetInterfacetable.

winlink1000OduEthernetIfEntry

N/A ODUEthernetInterfacetableentry.INDEX{
winlink1000OduEthernetIfIndex}

winlink1000OduEthernetIfIndex

1.3.6.1.4.1.4458.1000.1.3.2. Integer
1.1

RO

ODUEthernetInterfaceIndex.

winlink1000OduEthernetIfAddress

1.3.6.1.4.1.4458.1000.1.3.2. DisplayString
1.5

RO

ODUMACaddress.

winlink1000OduEthernetIfAdminSt
atus

1.3.6.1.4.1.4458.1000.1.3.2. Integer
1.6

RW Requiredstateoftheinterface.

winlink1000OduEthernetIfOperStat 1.3.6.1.4.1.4458.1000.1.3.2. Integer


us
1.7

RADWIN5000HPMPUserManual

Release3.5.50

RO

Currentoperationalstateoftheinterface.

C42

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet5of33)
OID

Type

winlink1000OduEthernetIfFailActio
n

1.3.6.1.4.1.4458.1000.1.3.2. Integer
1.8

winlink1000OduEthernetNumOfPor 1.3.6.1.4.1.4458.1000.1.3.3
ts

Integer

winlink1000OduEthernetGbeSuppo 1.3.6.1.4.1.4458.1000.1.3.4
rted

Integer

Access

Name

Description

RW Failureactionoftheinterface.
RO

NumberofODUnetworkinterfaces.
SupportedGigabitEthernetinODU.

winlink1000OduBridgeBasePortTabl
e

N/A ODUBridgePortstable.

winlink1000OduBridgeBasePortEntr
y

N/A ODUBridgePortstableentry.INDEX{
winlink1000OduBridgeBasePortIndex}

winlink1000OduBridgeBasePortInd
ex

RO

ODUBridgePortNumber.

winlink1000OduBridgeBaseIfIndex

RO

IfIndexcorrespondingtoODUBridgeport.

winlink1000OduBridgeTpMode

1.3.6.1.4.1.4458.1000.1.4.4. Integer
101

RW ODUbridgemode.Achangeiseffectiveafter
reset.Validvalues:hubMode(0)bridgeMode
(1).

winlink1000OduBridgeTpPortTable

N/A ODUTransparentBridgePortstable.

winlink1000OduBridgeTpPortEntry

N/A ODUTransparentBridgePortstableentry.
INDEX{winlink1000OduBridgeTpPortIndex}

winlink1000OduBridgeTpPortIndex

1.3.6.1.4.1.4458.1000.1.4.4. Integer
3.1.1

RO

ODUTransparentBridgePortNumber.

winlink1000OduBridgeTpPortInFra
mes

1.3.6.1.4.1.4458.1000.1.4.4. Counter
3.1.3

RO

Numberofframesreceivedbythisport.

winlink1000OduBridgeTpPortOutFr
ames

1.3.6.1.4.1.4458.1000.1.4.4. Counter
3.1.4

RO

Numberofframestransmittedbythisport.

winlink1000OduBridgeTpPortInByte 1.3.6.1.4.1.4458.1000.1.4.4. Counter


s
3.1.101

RO

Numberofbytesreceivedbythisport.

winlink1000OduBridgeTpPortOutBy 1.3.6.1.4.1.4458.1000.1.4.4. Counter


tes
3.1.102

RO

Numberofbytestransmittedbythisport.

winlink1000OduBridgeConfigMode

1.3.6.1.4.1.4458.1000.1.4.4. Integer
102

RO

ODUbridgeconfigurationmode

winlink1000OduAirFreq

1.3.6.1.4.1.4458.1000.1.5.1

Integer

RW InstallationCenterFrequency.Validvaluesare
productdependent.Achangeiseffectiveafter
linkresynchronization.

winlink1000OduAirDesiredRate

1.3.6.1.4.1.4458.1000.1.5.2

Integer

RW Deprecatedparameteractualbehaviorisread
only.RequiredAirRate.ForChannel
Bandwidthof20105MHzdividethevalueby
124respectively.

winlink1000OduAirSSID

1.3.6.1.4.1.4458.1000.1.5.3

DisplayString

RW ReservedfortheManagerapplicationprovided
withtheproduct.TheSectorIDinPointTo
MultiPointsystems.

winlink1000OduAirTxPower

1.3.6.1.4.1.4458.1000.1.5.4

Integer

RW RequiredTransmitpowerindBm.Thisisa
nominalvaluewhiletheactualtransmitpower
includesadditionalattenuation.Theminand
maxvaluesareproductspecific.Achangeis
effectiveimmediately.

winlink1000OduAirSesState

1.3.6.1.4.1.4458.1000.1.5.5

Integer

RO

CurrentLinkState.Thevalueisactive(3)during
normaloperation.

winlink1000OduAirMstrSlv

1.3.6.1.4.1.4458.1000.1.5.6

Integer

RO

Thisparameterindicatesifthedevicewas
automaticallyselectedintotheradiolinkmaster
orslave.Thevalueisundefinedifthereisno
link.Thevalueisrelevantonlyforpointto
pointsystems.

winlink1000OduAirResync

1.3.6.1.4.1.4458.1000.1.5.8

Integer

RW Settingthisparameterto1willcausethelinkto
restartthesynchronizationprocess.

RADWIN5000HPMPUserManual

Release3.5.50

C43

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet6of33)
Type

Access

Name

OID

Description

winlink1000OduAirRxPower

1.3.6.1.4.1.4458.1000.1.5.9. Integer
1

RO

ReceivedSignalStrengthindBm.Relevantonly
forpointtopointsystems.

winlink1000OduAirTotalFrames

1.3.6.1.4.1.4458.1000.1.5.9. Counter
2

RO

Totalnumberofradioframes.

winlink1000OduAirBadFrames

1.3.6.1.4.1.4458.1000.1.5.9. Counter
3

RO

TotalnumberofreceivedradioframeswithCRC
error.Thevalueisrelevantonlyforpointto
pointsystems.

winlink1000OduAirCurrentRate

1.3.6.1.4.1.4458.1000.1.5.9. Integer
4

RO

Deprecatedparameter.Actualrateoftheair
interfaceinMbps.ForChannelBandwidthof
20105MHzdividethevalueby124
respectively.

winlink1000OduAirCurrentRateIdx

1.3.6.1.4.1.4458.1000.1.5.9. Integer
5

RO

Indexofcurrentairrate.

winlink1000OduAirChainsRxPower

1.3.6.1.4.1.4458.1000.1.5.9. OctetString
6

RO

ReceivedSignalStrengthofCpechainsindBm.
Chain1RSS:(1Byte)Chain2RSS:(1Byte)
Chain3RSS:(1Byte)

winlink1000OduAirTxPower36

1.3.6.1.4.1.4458.1000.1.5.1
0

Integer

RW Deprecatedparameter.Actualbehaviorisread
only.

winlink1000OduAirTxPower48

1.3.6.1.4.1.4458.1000.1.5.1
1

Integer

RW Deprecatedparameter.Actualbehaviorisread
only.

winlink1000OduAirCurrentTxPower 1.3.6.1.4.1.4458.1000.1.5.1
2

Integer

RO

CurrentTransmitPowerindBm.Thisisa
nominalvaluewhiletheactualtransmitpower
includesadditionalattenuation.

winlink1000OduAirMinFrequency

1.3.6.1.4.1.4458.1000.1.5.1
3

Integer

RO

MinimumcenterfrequencyinMHz.

winlink1000OduAirMaxFrequency

1.3.6.1.4.1.4458.1000.1.5.1
4

Integer

RO

MaximumcenterfrequencyinMHz.

winlink1000OduAirFreqResolution

1.3.6.1.4.1.4458.1000.1.5.1
5

Integer

RO

CenterFrequencyresolution.Measuredin
MHzifvalue<100otherwiseinKHz.

winlink1000OduAirCurrentFreq

1.3.6.1.4.1.4458.1000.1.5.1
6

Integer

RO

CurrentCenterFrequency.MeasuredinMHzif
centerfrequencyresolutionvalue<100
otherwiseinKHz.

winlink1000OduAirNumberOfChan
nels

1.3.6.1.4.1.4458.1000.1.5.1
7

Integer

RO

Numberofchannelsthatcanbeused.

winlink1000OduAirChannelsTable

N/A Tableofchannelsusedbyautomaticchannels
selection(ACS).

winlink1000OduAirChannelsEntry

N/A ACSchannelstableentry.INDEX{
winlink1000OduAirChannelsIndex}

winlink1000OduAirChannelsIndex

RO

ChannelIndex.

winlink1000OduAirChannelsFreque
ncy

RO

ChannelfrequencyinMHz.

winlink1000OduAirChannelsOperSt
ate

RW Channelstate.Canbesetbytheuser.
AutomaticChannelSelectionuseschannelsthat
areAirChannelsOperStateenabledand
AirChannelsAvailenabled.Achangeis
effectiveafterlinkresynchronization.Valid
values:disabled(0)enabled(1).Rewriteable
onlyinPointToPointproducts.

winlink1000OduAirChannelsAvail

RO

Channelstate.Productspecificandcannotbe
changedbytheuser.AutomaticChannel
Selectionuseschannelsthatare
AirChannelsOperStateenabledand
AirChannelsAvailenabled.Validvalues:
disabled(0)enabled(1).

winlink1000OduAirChannelsDefault
Freq

RO

Defaultchannel'savailabilityforallCBWs.The
validvaluesare:forbidden(0)available(1).

RADWIN5000HPMPUserManual

Release3.5.50

C44

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet7of33)
Access

Name

OID

Type

Description

winlink1000OduAirDfsState

1.3.6.1.4.1.4458.1000.1.5.1
9

Integer

RO

Radardetectionstate.Validvalues:disabled(0)
enabled(1).

winlink1000OduAirAutoChannelSel
ectionState

1.3.6.1.4.1.4458.1000.1.5.2
0

Integer

RO

Deprecatedparameter.IndicatingAutomatic
ChannelSelectionavailabilityatcurrentchannel
bandwidth.Validvalues:disabled(0)enabled
(1).

winlink1000OduAirEnableTxPower

1.3.6.1.4.1.4458.1000.1.5.2
1

Integer

RO

IndicatingTransmitpowerconfiguration
enabledordisabled.

winlink1000OduAirMinTxPower

1.3.6.1.4.1.4458.1000.1.5.2
2

Integer

RO

MinimumTransmitpowerindBm.

winlink1000OduAirMaxTxPowerTab
le

N/A TableofMaximumtransmitpowerperairrate
indBm.

winlink1000OduAirMaxTxPowerEnt
ry

N/A MaximumTransmitpowertableentry.INDEX{
winlink1000OduAirMaxTxPowerIndex}

winlink1000OduAirMaxTxPowerInd
ex

1.3.6.1.4.1.4458.1000.1.5.2
3.1.1

Integer

RO

Airinterfacerateindex.

winlink1000OduAirMaxTxPower

1.3.6.1.4.1.4458.1000.1.5.2
3.1.2

Integer

RO

MaximumTransmitpowerindBm.

winlink1000OduAirChannelBandwi
dth

1.3.6.1.4.1.4458.1000.1.5.2
4

Integer

RW ChannelbandwidthinKHz.Achangeiseffective
afterreset.

winlink1000OduAirChannelBWTabl
e

N/A ChannelBandwidthstable.

winlink1000OduAirChannelBWEntr
y

N/A ChannelBandwidthtableentry.INDEX{
winlink1000OduAirChannelBWIndex}

winlink1000OduAirChannelBWInde 1.3.6.1.4.1.4458.1000.1.5.2
x
5.1.1

Integer

RO

ChannelBandwidthindex.

winlink1000OduAirChannelBWAvail 1.3.6.1.4.1.4458.1000.1.5.2
5.1.2

Integer

RO

ChannelBandwidthavailabilityproduct
specific.Optionsare:Notsupportedsupported
withmanualchannelselectionsupportedwith
AutomaticChannelSelection.

winlink1000OduAirChannelsAdmin
State

DisplayString

RO

Channels'availabilityperCBW.

winlink1000OduAirChannelBWHSS
ATDDConflictPerCBW

RO

IndicationforpossibleLinkdropperCBWdueto
conflictbetweenHSSandATDD.

winlink1000OduAirChannelBWMin
RatioForSupporting

RO

MinimalTXratiothatmaybeusedbytheHSM
andstillenableproperoperationofthe
aforementionedCBW.

winlink1000OduAirChannelBWMax
RatioForSupporting

RO

MaximalTXratiothatmaybeusedbytheHSM
andstillenableproperoperationofthe
aforementionedCBW.

RO

Currentradioframedurationinmicroseconds.

winlink1000OduAirRFD

1.3.6.1.4.1.4458.1000.1.5.2
5.1.3

1.3.6.1.4.1.4458.1000.1.5.2
6

Integer

winlink1000OduAirRatesTable

N/A AirRateindexestableforcurrentchannel
bandwidth.

winlink1000OduAirRatesEntry

N/A AirRateindexestableentry.INDEX{
winlink1000OduAirRatesIndex}

winlink1000OduAirRatesIndex

RO

AirRateindex.

winlink1000OduAirRatesAvail

RO

AirRateavailabilitydependingonairinterface
conditions.

winlink1000OduAirDesiredRateIdx

1.3.6.1.4.1.4458.1000.1.5.2
8

Integer

RW RequiredAirRateindex.0reservedforAdaptive
Rate.Achangeiseffectiveimmediatelyafter
Setoperationtothemastersidewhilethelink
isup.

winlink1000OduAirLinkDistance

1.3.6.1.4.1.4458.1000.1.5.2
9

Integer

RO

RADWIN5000HPMPUserManual

Release3.5.50

Linkdistanceinmeters.Avalueof1indicates
anillegalvalueandisalsousedwhenalinkis
notestablished.

C45

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet8of33)
Access

Name

OID

Type

Description

winlink1000OduAirLinkWorkingMo
de

1.3.6.1.4.1.4458.1000.1.5.3
0

Integer

RO

Linkworkingmodeasaresultofcomparing
versionsofbothsidesofthelink.Possible
modesare:UnknownnolinkNormalversions
onbothsidesareidenticalwithfull
compatibilitywithrestrictedcompatibilityor
versionsonbothsidesaredifferentwith
softwareupgradeorversionsincompatibility.

winlink1000OduAirMajorLinkIfVersi 1.3.6.1.4.1.4458.1000.1.5.3
on
1

Integer

RO

Majorlinkinterfaceversion

winlink1000OduAirMinorLinkIfVersi 1.3.6.1.4.1.4458.1000.1.5.3
on
2

Integer

RO

Minorlinkinterfaceversion

winlink1000OduAirHssDesiredOpSt
ate

1.3.6.1.4.1.4458.1000.1.5.4
0.1

Integer

RW RequiredHubSiteSynchronizationoperating
state.ForHssSyncUnits:ForhssISU:[27]For
hssGSU:[26]ForHBS:[2345]

winlink1000OduAirHssCurrentOpSt
ate

1.3.6.1.4.1.4458.1000.1.5.4
0.2

Integer

RO

CurrentHubSiteSynchronizationoperating
state.

winlink1000OduAirHssSyncStatus

1.3.6.1.4.1.4458.1000.1.5.4
0.3

Integer

RO

HubSiteSynchronizationsyncstatus.

winlink1000OduAirHssExtPulseStat
us

1.3.6.1.4.1.4458.1000.1.5.4
0.4

Integer

RO

HubSiteSynchronizationexternalpulse
detectionstatus.InGSSmode:ifgenerating
then1PSPisautogeneratedbytheGSSUnit.if
generatingAndDetectingthen1PSPisgenerated
byGPSsatellitessignal.

winlink1000OduAirHssExtPulseType 1.3.6.1.4.1.4458.1000.1.5.4
0.5

Integer

RO

HubSiteSynchronizationexternalpulsetype.

winlink1000OduAirHssDesiredExtPu 1.3.6.1.4.1.4458.1000.1.5.4
lseType
0.6

Integer

RW HubSiteSynchronizationrequiredexternal
pulsetype.Validvaluesforreadwrite:
{typeA(2)typeB(3)typeC(4)typeD(5)typeE(6)
typeF(7)}.Validvalueforreadonly:
{notApplicable(1)}.

winlink1000OduAirHssRfpTable

N/A ODURadioFramePatterns(RFP)Table.

winlink1000OduAirHssRfpEntry

N/A ODURFPTableentry.INDEX{
winlink1000OduAirHssRfpIndex}

winlink1000OduAirHssRfpIndex

1.3.6.1.4.1.4458.1000.1.5.4
0.7.1.1

Integer

RO

ODURFPTableindex.Theindexrepresentthe
RadioFramePattern:typeA(2)typeB(3)
typeC(4)typeD(5)typeE(6).

winlink1000OduAirHssRfpEthChann 1.3.6.1.4.1.4458.1000.1.5.4
elBW5MHz
0.7.1.2

Integer

RO

RepresentsthecompatibilityofEthernetservice
underChannelBWof5MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpTdmChan 1.3.6.1.4.1.4458.1000.1.5.4
nelBW5MHz
0.7.1.3

Integer

RO

RepresentsthecompatibilityofTDMservice
underChannelBWof5MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpEthChann 1.3.6.1.4.1.4458.1000.1.5.4
elBW10MHz
0.7.1.4

Integer

RO

RepresentsthecompatibilityofEthernetservice
underChannelBWof10MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpTdmChan 1.3.6.1.4.1.4458.1000.1.5.4
nelBW10MHz
0.7.1.5

Integer

RO

RepresentsthecompatibilityofTDMservice
underChannelBWof10MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpEthChann 1.3.6.1.4.1.4458.1000.1.5.4
elBW20MHz
0.7.1.6

Integer

RO

RepresentsthecompatibilityofEthernetservice
underChannelBWof20MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpTdmChan 1.3.6.1.4.1.4458.1000.1.5.4
nelBW20MHz
0.7.1.7

Integer

RO

RepresentsthecompatibilityofTDMservice
underChannelBWof20MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpEthChann 1.3.6.1.4.1.4458.1000.1.5.4
elBW40MHz
0.7.1.8

Integer

RO

RepresentsthecompatibilityofEthernetservice
underChannelBWof40MHzinthespecific
RadioFramePattern.

RADWIN5000HPMPUserManual

Release3.5.50

C46

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet9of33)
OID

Type

Access

Name

Description

winlink1000OduAirHssRfpTdmChan 1.3.6.1.4.1.4458.1000.1.5.4
nelBW40MHz
0.7.1.9

Integer

RO

RepresentsthecompatibilityofTDMservice
underChannelBWof40MHzinthespecific
RadioFramePattern.

winlink1000OduAirHssRfpStr

1.3.6.1.4.1.4458.1000.1.5.4
0.8

DisplayString

RO

HubSiteSynchronizationsupportedpatterns

winlink1000OduAirHssHsmID

1.3.6.1.4.1.4458.1000.1.5.4
0.9

Integer

RO

AuniqueIDwhichiscommontotheHSMand
allitscollocatedODUs

winlink1000OduAirHssTime

1.3.6.1.4.1.4458.1000.1.5.4
0.10

DisplayString

RO

HubSiteSynchronizationGPStime

winlink1000OduAirHssLatitude

1.3.6.1.4.1.4458.1000.1.5.4
0.11

DisplayString

RO

HubSiteSynchronizationGPSLatitude

winlink1000OduAirHssNSIndicator

1.3.6.1.4.1.4458.1000.1.5.4
0.12

DisplayString

RO

HubSiteSynchronizationGPSN/SIndicator

winlink1000OduAirHssLongitude

1.3.6.1.4.1.4458.1000.1.5.4
0.13

DisplayString

RO

HubSiteSynchronizationGPSLongitude

winlink1000OduAirHssEWIndicator

1.3.6.1.4.1.4458.1000.1.5.4
0.14

DisplayString

RO

HubSiteSynchronizationGPSE/WIndicator

winlink1000OduAirHssNumSatellite 1.3.6.1.4.1.4458.1000.1.5.4
s
0.15

DisplayString

RO

HubSiteSynchronizationGPSNumberof
satellites

winlink1000OduAirHssAltitude

1.3.6.1.4.1.4458.1000.1.5.4
0.16

DisplayString

RO

HubSiteSynchronizationGPSAltitude

winlink1000OduAirHssRfpPhase

1.3.6.1.4.1.4458.1000.1.5.4
0.17

Integer

RW HubSiteSynchronizationGPSRFPphase

winlink1000OduAirHssInterSiteSync
hronizationMode

RW InterSiteSynchronizationModeindependent/
synchronized

winlink1000OduAirHssInterSiteSync
hronizationAvailability

RO

winlink1000OduAirHssSatellitesSatS
yncRequired

RW SatellitesSynchronizationIsRequired

winlink1000OduAirHssDomainID

RW EHSSdomain.IndentifysetofCUswithsame
HSSsynchronization

winlink1000OduAirHssSupportedSy
nchronizationProtocol

RO

winlink1000OduAirHssDesiredSync
hronizationProtocol

RW DesiredSynchronizationProtocols

winlink1000OduAirHssDiscover

RW InitiateDiscoveryprocessofODUsonthe
network.

winlink1000OduAirHssNumberOfDi
scoveredODUs

RO

winlink1000OduAirHssDiscoverTabl
e

N/A HSSDiscoverTable.

winlink1000OduAirHssDiscoverEntr
y

N/A ODUDiscoverTableentry.INDEX{
winlink1000OduAirHssDiscoverIndex}

winlink1000OduAirHssDiscoverInde
x

RO

HSSDiscoverTableIndex.

winlink1000OduAirHssDiscoverODU
Description

RO

HoldODUHSSstatusincompressformat:
DomainIPHSSRoleHsssupportEnabledHSS
protocolSyncStatusLocationIPv6.

winlink1000OduAirHssMasterSlave
Compatibility

RO

EHSMversioncompatibility.Relevantto
EthernetHSSClientsonly.

winlink1000OduAirHssNumberOfAs
sociatedCU

RO

NumberofassociatedEthernetHSSClients.
RelevanttoEthernetHSSMastersonly

winlink1000OduAirHssAssociatedC
UTable

N/A AssociatedEthernetHSSClientsTable.Releant
forEthernetHSSMastersonly.

RADWIN5000HPMPUserManual

Release3.5.50

InterSiteSynchronizationAvailability

SupportedSynchronizationProtocols

NumberOFDiscoveredODUsinnetwork.

C47

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet10of33)
OID

Type

Access

Name

Description

winlink1000OduAirHssAssociatedC
UTableEntry

N/A AssociatedEthernetHSSClientsTableEntry.
ReleantforEthernetHSSMastersonly.INDEX{
winlink1000OduAirHssAssociatedCUIndex}

winlink1000OduAirHssAssociatedC
UIndex

RO

AssociatedEthernetHSSClientsTableIndex.
ReleantforEthernetHSSMastersonly.

winlink1000OduAirHssAssociatedC
UDescription

RO

HoldsAssociatedEthernetHSSClients
Descriptionincompressformat:IPDelay
CompatibilityEthernetSpeedEthernetRxrate
IPv6

winlink1000OduAirHssSyncStatusEt
h

RO

EthernetHSSClientSynchronizationLevel

winlink1000OduAirHssEthVLANTag

RW EthernetHSSVLanTag:Theleastsignificate
decimaldigitistheVLanPriority(06)andthe
restofthedigitsrepresentsVLanID(24094)

winlink1000OduAirHssHSMIPAddre
ss

RO

HSMsIPaddress.RelevantforHSCsynchronized
overEthernet.

winlink1000OduAirHssDelayToHSM

RO

DelayinmicrosecondstoHSM.RelevantforHSC
synchronizedoverEthernet.

winlink1000OduAirHssSyncAcquisiti
onSeconds

RW Accumulatedquantityofsecondsinclock
acquisitionwhileconnectedtocurrentHSM

winlink1000OduAirHssHSMIPv6Add
ress

RO

HSMsIPv6address.RelevantforHSC
synchronizedoverEthernet.

winlink1000OduAirLockRemote

1.3.6.1.4.1.4458.1000.1.5.4
1

Integer

RW Thisparameterenableslockingthelinkwitha
specificODU.Thefollowingvaluescanbeset:
Unlock(default)TheODUisnotlockedona
specificremoteODU.Unlockcanonlybe
performedwhenthelinkisnotconnected.
LockTheODUislockedonaspecificremote
ODU.Lockcanonlybeperformedwhenthelink
isactive.

winlink1000OduAirAntennaGain

1.3.6.1.4.1.4458.1000.1.5.4
2

Integer

RW CurrentAntennaGainin0.1dBiresolution.User
definedvalueforexternalantenna.Legal
range:
MinAntennaGain<AntennaGain<MaxAntennaG
ain.

winlink1000OduAirFeederLoss

1.3.6.1.4.1.4458.1000.1.5.4
3

Integer

RW CurrentFeederLossin0.1dBmresolution.User
definedvalueforexternalantenna.

winlink1000OduAirMaxAntennaGai 1.3.6.1.4.1.4458.1000.1.5.4
n
4

Integer

RO

MaximumallowedAntennaGainin0.1dBi
resolution.

winlink1000OduAirMinAntennaGai
n

1.3.6.1.4.1.4458.1000.1.5.4
5

Integer

RO

MinimumallowedAntennaGainin0.1dBi
resolution.

winlink1000OduAirMaxEIRP

1.3.6.1.4.1.4458.1000.1.5.4
6

Integer

RO

MaximumEIRPvalueasdefinedbyregulationin
0.1dBmresolution.

winlink1000OduAirAntennaGainCo
nfigSupport

1.3.6.1.4.1.4458.1000.1.5.4
7

Integer

RO

AntennaGainConfigurabilityoptionsare
productspecific:supportednotsupported.

winlink1000OduAirAntennaType

1.3.6.1.4.1.4458.1000.1.5.4
8

Integer

RW ExternalAntennaType:MonopolarorBipolar.

winlink1000OduAirRssBalance

1.3.6.1.4.1.4458.1000.1.5.4
9

Integer

RO

RSSbalance.RelationbetweenRSSinradio1
andRSSinradio2.2:Radio2RSSismuch
strongerthanRadio1RSS.1:Radio2RSSis
strongerthanRadio1RSS.0:Radio2RSSis
equaltoRadio1RSS.1:Radio1RSSisstronger
thanRadio2RSS.2:Radio1RSSismuch
strongerthanRadio2RSS.

winlink1000OduAirTotalTxPower

1.3.6.1.4.1.4458.1000.1.5.5
0

Integer

RO

TotalTransmitPowerindBm.Thisisanominal
valueWhiletheactualtransmitpowerincludes
additionalattenuation.

RADWIN5000HPMPUserManual

Release3.5.50

C48

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet11of33)
Access

Name

OID

Type

Description

winlink1000OduAirInstallFreqAndC
BW

1.3.6.1.4.1.4458.1000.1.5.5
1

DisplayString

RW InstallationfrequencyChannelBW.Relevantin
pointtopointsystems.

winlink1000OduAirDFStype

1.3.6.1.4.1.4458.1000.1.5.5
2

Integer

RO

DFSregulationtype.

winlink1000OduAirComboSubBand
Table

N/A ODUMultibandSubBandsTable.

winlink1000OduAirComboSubBand
Entry

N/A ODUMultibandSubBandsTableentry.INDEX
{winlink1000OduAirComboSubBandIndex}

winlink1000OduAirComboSubBandI 1.3.6.1.4.1.4458.1000.1.5.5
ndex
3.1.1.1

Integer

RO

ODUMultibandsubbandstableindex.

winlink1000OduAirComboSubBandI 1.3.6.1.4.1.4458.1000.1.5.5
d
3.1.1.2

DisplayString

RO

RepresentstheMultibandsubbandID.

winlink1000OduAirComboSubBand
Description

DisplayString

RO

Multibandsubbanddescription.

winlink1000OduAirComboSubBandI 1.3.6.1.4.1.4458.1000.1.5.5
nstallFreq
3.1.1.4

Integer

RO

RepresentstheMultibandsubbandinstallation
frequencyinKHz.

winlink1000OduAirComboSubBand
AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.5

Integer

RO

RepresentstheMultibandsubband
administrativestate.

winlink1000OduAirComboSubBandI 1.3.6.1.4.1.4458.1000.1.5.5
nstallationAllowed
3.1.1.6

Integer

RO

ReflectsiftheMultibandsubbandallowes
installtion.

winlink1000OduAirComboFrequenc 1.3.6.1.4.1.4458.1000.1.5.5
yBandId
3.1.1.7

Integer

RO

ReflectsthefrequencybandId.

winlink1000OduAirComboSubBand
ChannelBW5AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.8

DisplayString

RO

ReflectstheCBW5MHzadminstatevector.

winlink1000OduAirComboSubBand
ChannelBW10AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.9

DisplayString

RO

ReflectstheCBW10MHzadminstatevector.

winlink1000OduAirComboSubBand
ChannelBW20AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.10

DisplayString

RO

ReflectstheCBW20MHzadminstatevector.

winlink1000OduAirComboSubBand
ChannelBW40AdminState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.11

DisplayString

RO

ReflectstheCBW40MHzadminstatevector.

winlink1000OduAirComboSubBand
AllowableChannels

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.12

DisplayString

RO

Reflectstheallowablechannelsvector.

winlink1000OduAirComboSubBand
ChannelBWAvail

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.13

DisplayString

RO

ReflectstheavailableCBWsvector.

winlink1000OduAirComboSubBand
ChannelBandwidth

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.14

Integer

RO

Reflectsthesubbanddefaultchannel
bandwidth.

winlink1000OduAirComboSubBand
MinFreq

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.15

Integer

RO

Reflectsthesubbanddefaultminimal
frequency.

winlink1000OduAirComboSubBand
MaxFreq

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.16

Integer

RO

Reflectsthesubbanddefaultmaximal
frequency.

winlink1000OduAirComboSubBand
FrequencyResolution

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.17

Integer

RO

Reflectsthesubbandfrequencyresolution.

winlink1000OduAirComboSubBand
DefaultChannelList

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.18

DisplayString

RO

Reflectsthedefaultchannellistvector.

winlink1000OduAirComboSubBand
DfsState

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.19

Integer

RO

ReflectsthesubbandDFSstate.

winlink1000OduAirComboNumber
OfSubBands

1.3.6.1.4.1.4458.1000.1.5.5
3.2

Integer

RO

RepresentsthenumberofMultibandsub
bands.

winlink1000OduAirComboSwitchSu 1.3.6.1.4.1.4458.1000.1.5.5
bBand
3.3

DisplayString

RW Switchsubbandoperationwithagivensub
bandID.Thegetoperationretrievesthe
currentsubbandID.

winlink1000OduAirComboCurrentS
ubBandDesc

DisplayString

RO

CurrentSubBanddescription.

Integer

RO

MaxEthernetthroughputofthesite(inKpbs).

1.3.6.1.4.1.4458.1000.1.5.5
3.1.1.3

1.3.6.1.4.1.4458.1000.1.5.5
3.4

winlink1000OduAirInternalMaxRate 1.3.6.1.4.1.4458.1000.1.5.5
4

RADWIN5000HPMPUserManual

Release3.5.50

C49

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet12of33)
OID

Type

winlink1000OduAirCapacityDirectio
n

Access

Name

Description

RW Capacitydirectionofthesite.

winlink1000OduAirSpectrumAnalysi 1.3.6.1.4.1.4458.1000.1.5.5
sOperState
6.1

Integer

RW SpectrumAnalysisoperationstate.The
configurablevaluesareSpectrumAnalysisStop
StartandRestart.NotSupportedvalue
indicatesthatthefeatureisnotsupportedon
thedevice.NotSupportedisnota
configurablestate.

winlink1000OduAirRxPowerAntenn 1.3.6.1.4.1.4458.1000.1.5.5
aA
6.2

Integer

RO

ReceivedSignalStrengthindBmofAntennaA.

winlink1000OduAirRxPowerAntenn 1.3.6.1.4.1.4458.1000.1.5.5
aB
6.3

Integer

RO

ReceivedSignalStrengthindBmofAntennaB.

winlink1000OduAirNumberOfSpect 1.3.6.1.4.1.4458.1000.1.5.5
rumChannels
6.4

Integer

RO

RepresentsthenumberofSpectrumChannels.

winlink1000OduAirSpectrumChann
elTable

N/A ODUSpectrumAnalysisChannelTable.

winlink1000OduAirSpectrumChann
elTableEntry

N/A ODUSpectrumAnalysisChannelTableentry.
INDEX{
winlink1000OduAirSpectrumChannelIndex}

winlink1000OduAirSpectrumChann
elIndex

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.1

Integer

RO

ODUSpectrumChannelindex.

winlink1000OduAirSpectrumChann
elFrequency

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.2

Integer

RO

ODUSpectrumChannelfrequencyinMHz.

winlink1000OduAirSpectrumChann
elScanned

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.3

Integer

RO

Anindicationofthevaildityofthechannel's
data.Ifthechannelwasscannedthedatais
valid,elsenot.

winlink1000OduAirSpectrumChann
elScanningTimestamp

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.4

TimeTicks

RO

Channellastscantimestampinhundredthsofa
secondsincedeviceuptime.Ifthechannel
wasnotscannedthanthereturnvaluewillbe0.

winlink1000OduAirSpectrumChann
elLastNFAntennaA

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.5

Integer

RO

NormalizedNoiseFloorvalueindBmof
AntennaA(including2neighborfrequencies).

winlink1000OduAirSpectrumChann
elLastNFAntennaB

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.6

Integer

RO

NormalizedNoiseFloorvalueindBmof
AntennaB(including2neighborfrequencies).

winlink1000OduAirSpectrumChann
elAverageNFAntennaA

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.7

Integer

RO

AveragenormalizedNoiseFloorvalueindBm
ofAntennaAoveralldwells.

winlink1000OduAirSpectrumChann
elAverageNFAntennaB

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.8

Integer

RO

AveragenormalizedNoiseFloorvalueindBm
ofAntennaBoveralldwells.

winlink1000OduAirSpectrumChann
elMaxNFAntennaA

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.9

Integer

RO

MaxnormalizedNoiseFloorvalueindBmof
AntennaAoveralldwells.

winlink1000OduAirSpectrumChann
elMaxNFAntennaB

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.10

Integer

RO

MaxnormalizedNoiseFloorvalueindBmof
AntennaBoveralldwells.

winlink1000OduAirSpectrumChann
elCACPerformed

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.11

Integer

RO

WasCACperformedonthechannel.

winlink1000OduAirSpectrumChann
elLastCACTimestamp

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.12

TimeTicks

RO

LastCACperformedtimestampinhundredths
ofasecondsincedeviceuptime.IfnoCAChas
performedonthechannelthereturnvaluewill
be0.

winlink1000OduAirSpectrumChann
elRadarDetected

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.13

Integer

winlink1000OduAirSpectrumChann
elRadarDetectionTimestamp

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.14

TimeTicks

RO

LastRadarDetectiontimestampinhundredths
ofasecondsincedeviceuptime.IfnoRadar
hasdetectedonthechannelthereturnvalue
willbe0.

winlink1000OduAirSpectrumChann
elAvailable

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.15

Integer

RO

Isthechannelavailableforuse.

winlink1000OduAirSpectrumChann
elMaxBeaconRss

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.16

Integer

RO

ThemaxRSSvalueofareceivedbeacononthe
specificchannelindBm.

RADWIN5000HPMPUserManual

Release3.5.50

WasRadardetectedonthechannel.

C50

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet13of33)
Access

Name

OID

Type

winlink1000OduAirSpectrumChann
elCompressed

1.3.6.1.4.1.4458.1000.1.5.5
6.5.1.17

OctetString

RO

CompressalltheSpectrumdataperchannel
intoonevariable.Frequency(4bytes)
Scanned(1byte)Timestamp(4bytes)LastNF
AntennaA(1byte)LastNFAntennaB(1byte)
AvgNFAntennaA(1byte)AvgNFAntennaB(1
byte)MaxNFAntennaA(1byte)MaxNF
AntennaB(1byte)CACPerformed(1byte)
LastCACTimestamp(4bytes)RadarDetected
(1byte)RadarDetectedTimestamp(4bytes)
ChannelAvailable(1byte)MaxBeaconRSS(1
byte).

winlink1000OduAirChipMinMaxFre
q

1.3.6.1.4.1.4458.1000.1.5.5
6.6

DisplayString

RO

Theminimumandmaximumfrequenciesin
MHzwhichthechipsupports.

winlink1000OduAirSpectrumAnalysi
sTimeout

Description

RW Spectrumanalysistimeoutinseconds.

winlink1000OduAirAntConfAndRate 1.3.6.1.4.1.4458.1000.1.5.5
sStatus
7

Integer

RO

winlink1000OduAirDualAntTxMode 1.3.6.1.4.1.4458.1000.1.5.5
8

Integer

RW Description:TransmissiontypewhenusingDual
radios(MIMOorAdvancedDiversityusingone
streamofdata).

winlink1000OduAirTxOperationMo
de

Integer

RW ThisparametercontrolstheOperationmodeof
framessentovertheair.TheOperationmode
iseithernormal(1)forregulartransmission
whereframesizeisdeterminedbythetrafficor
throughputtest(2)whentheuserrequestsan
actualovertheairthroughputestimationusing
fullframes.Thelatterlastsnomorethana
predeterminedinterval(default30sec).

1.3.6.1.4.1.4458.1000.1.5.5
9

Description:AntennaconfigurationandRates
status(1=Singleantennawithsingledata
stream2=Dualantennawithsingledata
stream3=Dualantennawithdualdata
stream).

winlink1000OduAirDesiredNetMast
erTxRatio

RW Thisparameterisreservedtotheelement
managerprovidedwiththeproduct.

winlink1000OduAirCurrentNetMast
erTxRatio

RO

RepresentstheactualNetMasterTxRAtio.

winlink1000OduAirMinUsableMast
erTxRatio

RO

Representstheminimalvaluetheusercan
configureforDesirednetmAsterTxRatio.

winlink1000OduAirMaxUsableMast
erTxRatio

RO

Representsthemaximalvaluetheusercan
configureforDesirednetmAsterTxRatio.

winlink1000OduAirAccumulatedUA
S

1.3.6.1.4.1.4458.1000.1.5.6
1

Integer

RO

AccumulatestheUnavailablesecondsoftheAir
Interface.Relevantforpointtopointsystems.

winlink1000OduAirDistStr

1.3.6.1.4.1.4458.1000.1.5.6
2

DisplayString

RO

PossibilitiesofthelinkaccordingtoRFPand
CBW

winlink1000OduAirChannelsDefault 1.3.6.1.4.1.4458.1000.1.5.6
FreqStr
3

DisplayString

RO

Astringrepresentingthechannelsavailable.
Eachcharacterrepresentsonefrequencywhen
'1'meansitsavailableand'0'meansitsnot.

winlink1000OduAirAntConnectionT 1.3.6.1.4.1.4458.1000.1.5.6
ype
4

Integer

RW Antennaconnectiontype(External(1)
Integrated(2)Embedded_External(3)
Embedded_Integrated(4)EmbeddedBSA(5)).

winlink1000OduAirAllowableChann 1.3.6.1.4.1.4458.1000.1.5.6
elsStr
5

DisplayString

RW Astringrepresentingtheallowablechannels.
Eachcharacterrepresentsonechannelwhen'1'
meansitsavailableand'0'meansitsnot.

winlink1000OduAirDfsAlgorithmTyp 1.3.6.1.4.1.4458.1000.1.5.6
eState
6.1

Integer

RW BitmapforstateofRadarAlgorithmType.Filters
bybit'sposition:0=ZeroPW1=Fixed2=
Variable3=Staggered4=Long.

winlink1000OduAirDfsLastDetected
Tbl

N/A Lastdetectedradarstable.

winlink1000OduAirDfsLastDetected
Entry

N/A ODUMultibandSubBandsTableentry.INDEX
{winlink1000OduAirDfsLastDetectedIndex}

RADWIN5000HPMPUserManual

Release3.5.50

C51

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet14of33)
OID

Type

Access

Name

Description

winlink1000OduAirDfsLastDetected 1.3.6.1.4.1.4458.1000.1.5.6
Index
6.2.1.1

Integer

RO

DfsLastDetectedRadarsTableIndex.

winlink1000OduAirDfsLastDetected 1.3.6.1.4.1.4458.1000.1.5.6
Time
6.2.1.2

TimeTicks

RO

Dfstimeofthelastdetectedradar.

winlink1000OduAirDfsLastDetected 1.3.6.1.4.1.4458.1000.1.5.6
AlgorithmType
6.2.1.3

Integer

RO

Dfstypeofthelastdetectedradar.

winlink1000OduAirDfsLastDetected 1.3.6.1.4.1.4458.1000.1.5.6
Frequency
6.2.1.4

Integer

RO

Dfsfrequencyofthelastdetectedradar.

winlink1000OduAirPreferredChann
elsStr

RW Astringrepresentingthepreferredchannels.
Eachcharacterrepresentsonechannelwhen'1'
meansitspreferredand'0'meansitsnot.

winlink1000OduAirSyncLossThresh
old

RW Whenthecurrentthroughputisbelowthis
threshold(inKbps)synclosswilloccur.

winlink1000OduAirGeoLocation

1.3.6.1.4.1.4458.1000.1.5.6
9

winlink1000OduAirAggregateCapaci 1.3.6.1.4.1.4458.1000.1.5.7
ty
0

DisplayString

RW Geographicdevicelocationinformat:latitude
longitude.

Integer

RO

AggregateCapacityoftheODUinMbps.

winlink1000OduAirALPMDataBuffer
Str

RW AstringthatholdsalloftheALPMeventsdata

winlink1000OduAirCurrentManualA
ngle

RO

Absolute(manual)angle(Deg.)oftheunit.

winlink1000OduAirCurrentManualE
levAngle

RO

AbsoluteElevationangle(Deg.)oftheunit.

winlink1000OduPerfMonCurrTable

N/A Thistabledefines/keepsthecountersofthe
current15mininterval.

winlink1000OduPerfMonCurrEntry

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000OduPerfMonCurrUAS

1.3.6.1.4.1.4458.1000.1.6.1. Gauge
1.1

RO

ThecurrentnumberofUnavailableSeconds
startingfromthepresent15minutesperiod.

winlink1000OduPerfMonCurrES

1.3.6.1.4.1.4458.1000.1.6.1. Gauge
1.2

RO

CurrentnumberofErroredSecondsstarting
fromthepresent15minutesperiod.

winlink1000OduPerfMonCurrSES

1.3.6.1.4.1.4458.1000.1.6.1. Gauge
1.3

RO

CurrentnumberofSeverelyErroredSeconds
startingfromthepresent15minutesperiod.

winlink1000OduPerfMonCurrBBE

1.3.6.1.4.1.4458.1000.1.6.1. Gauge
1.4

RO

CurrentnumberofBackgroundBlockErrors
startingfromthepresent15minutesperiod.

winlink1000OduPerfMonCurrIntegri 1.3.6.1.4.1.4458.1000.1.6.1. Integer


ty
1.5

RO

Indicatestheintegrityoftheentry.

winlink1000OduPerfMonCurrComp 1.3.6.1.4.1.4458.1000.1.6.1. OctetString


ressed
1.6

RO

Holdsacompressedstringofalldataper
interface.CompressedAirInterfaceStructure
(sizeinbrackets):UAS(4)ES(4)SES(4)BBE
(4)Integrity(1)MinRSL(1)MaxRSL(1)
RSLThresh1Exceeded(4)RSLThresh2Exceeded
(4)MinTSL(1)MaxTSL(1)TSLThresh1Exceed
(4)BBERThresh1Exceed(4)RxMBytes(4)
TxMBytes(4)EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)Compressed
EtherentODUinterface(sizeinbrackets):UAS
(4)ES(4)SES(4)BBE(4)Integrity(1)
RxMBytes(4)TxMBytes(4)
EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)ActiveSeconds(4)

winlink1000OduPerfMonIntervalTa
ble

N/A Thistabledefines/keepsthecountersofthelast
day(inresolutionof15minintervals).

winlink1000OduPerfMonIntervalEn
try

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndexwinlink1000OduPerfMonIntervalIdx}

winlink1000OduPerfMonIntervalIdx

RO

RADWIN5000HPMPUserManual

Release3.5.50

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

C52

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet15of33)
OID

Type

Access

Name

Description

winlink1000OduPerfMonIntervalUA
S

RO

ThecurrentnumberofUnavailableSecondsper
interval.

winlink1000OduPerfMonIntervalES

RO

CurrentnumberofErroredSecondsperinterval.

winlink1000OduPerfMonIntervalSE
S

RO

CurrentnumberofSeverelyErroredSecondsper
interval.

winlink1000OduPerfMonIntervalBB
E

RO

CurrentnumberofBackgroundBlockErrorsper
interval.

winlink1000OduPerfMonIntervalInt
egrity

RO

Indicatestheintegrityoftheentryperinterval.

winlink1000OduPerfMonIntervalCo
mpressed

RO

Holdsacompressedstringofalldataper
interface.CompressedAirInterfaceStructure
(sizeinbrackets):UAS(4)ES(4)SES(4)BBE
(4)Integrity(1)MinRSL(1)MaxRSL(1)
RSLThresh1Exceeded(4)RSLThresh2Exceeded
(4)MinTSL(1)MaxTSL(1)TSLThresh1Exceed
(4)BBERThresh1Exceed(4)RxMBytes(4)
TxMBytes(4)EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)Compressed
EtherentODUinterface(sizeinbrackets):UAS
(4)ES(4)SES(4)BBE(4)Integrity(1)
RxMBytes(4)TxMBytes(4)
EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)ActiveSeconds(1)

winlink1000OduPerfMonDayTable

N/A Thistabledefines/keepsthecountersofthelast
month(inresolutionofdays).

winlink1000OduPerfMonDayEntry

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonDayIdx}

winlink1000OduPerfMonDayIdx

RO

Thistableisindexedperintervalnumber.Each
intervalisof24hoursandtheoldestis30.

winlink1000OduPerfMonDayUAS

RO

ThecurrentnumberofUnavailableSecondsper
intervalof24hours.

winlink1000OduPerfMonDayES

RO

CurrentnumberofErroredSecondsperinterval
of24hours.

winlink1000OduPerfMonDaySES

RO

CurrentnumberofSeverelyErroredSecondsper
intervalof24hours.

winlink1000OduPerfMonDayBBE

RO

CurrentnumberofBackgroundBlockErrorsper
intervalof24hours.

winlink1000OduPerfMonDayIntegri
ty

RO

Indicatestheintegrityoftheentryperinterval
of24hours.

winlink1000OduPerfMonDayCompr
essed

RO

Holdsacompressedstringofalldataper
interface.CompressedAirInterfaceStructure
(sizeinbrackets):UAS(4)ES(4)SES(4)BBE
(4)Integrity(1)MinRSL(1)MaxRSL(1)
RSLThresh1Exceeded(4)RSLThresh2Exceeded
(4)MinTSL(1)MaxTSL(1)TSLThresh1Exceed
(4)BBERThresh1Exceed(4)RxMBytes(4)
TxMBytes(4)EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)Compressed
EtherentODUinterface(sizeinbrackets):UAS
(4)ES(4)SES(4)BBE(4)Integrity(1)
RxMBytes(4)TxMBytes(4)
EthCapacityThreshUnder(4)
HighTrafficThreshExceed(4)ActiveSeconds(1)

winlink1000OduPerfMonAirCurrTab
le

N/A Thistabledefines/keepstheaircountersofthe
current15mininterval.

winlink1000OduPerfMonAirCurrEnt
ry

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000OduPerfMonAirCurrMi
nRSL

1.3.6.1.4.1.4458.1000.1.6.4. Integer
1.1

RADWIN5000HPMPUserManual

Release3.5.50

RO

CurrentMinReceivedLevelReferencestarting
fromthepresent15minutesperiod.

C53

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet16of33)
OID

Type

Access

Name

Description

winlink1000OduPerfMonAirCurrMa 1.3.6.1.4.1.4458.1000.1.6.4. Integer


xRSL
1.2

RO

CurrentMaxReceivedLevelReferencestarting
fromthepresent15minutesperiod.

winlink1000OduPerfMonAirCurrRSL 1.3.6.1.4.1.4458.1000.1.6.4. Gauge


Thresh1Exceed
1.3

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL1thresholdinthelast15
minutes.

winlink1000OduPerfMonAirCurrRSL 1.3.6.1.4.1.4458.1000.1.6.4. Gauge


Thresh2Exceed
1.4

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL2thresholdinthelast15
minutes.

winlink1000OduPerfMonAirCurrMi
nTSL

1.3.6.1.4.1.4458.1000.1.6.4. Integer
1.5

RO

CurrentMinTransmitSignalLevelstartingfrom
thepresent15minutesperiod.

winlink1000OduPerfMonAirCurrMa 1.3.6.1.4.1.4458.1000.1.6.4. Integer


xTSL
1.6

RO

CurrentMaxTransmitSignalLevelstartingfrom
thepresent15minutesperiod.

winlink1000OduPerfMonAirCurrTSL 1.3.6.1.4.1.4458.1000.1.6.4. Gauge


Thresh1Exceed
1.7

RO

NumberofsecondsTransmitSignalLevel
exceededtheTSL1thresholdinthelast15
minutes.

winlink1000OduPerfMonAirCurrBB
ERThresh1Exceed

RO

NumberofsecondsBackgroundBlockError
RatioexceededtheBBER1thresholdinthelast
15minutes.

1.3.6.1.4.1.4458.1000.1.6.4. Gauge
1.8

winlink1000OduPerfMonAirInterval
Table

N/A Thistabledefines/keepstheaircountersofthe
lastday(inresolutionof15minintervals).

winlink1000OduPerfMonAirInterval
Entry

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndexwinlink1000OduPerfMonAirIntervalIdx
}

winlink1000OduPerfMonAirInterval
Idx

RO

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonAirInterval
MinRSL

RO

CurrentMinReceivedLevelReferenceper
interval.

winlink1000OduPerfMonAirInterval
MaxRSL

RO

CurrentMaxReceivedLevelReferenceper
interval.

winlink1000OduPerfMonAirInterval
RSLThresh1Exceed

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL1thresholdperinterval.

winlink1000OduPerfMonAirInterval
RSLThresh2Exceed

NumberofsecondsReceiveSignalLevel
exceededtheRSL2thresholdACCESSreadonly
perinterval.

winlink1000OduPerfMonAirInterval
MinTSL

RO

CurrentMinTransmitSignalLevelperinterval.

winlink1000OduPerfMonAirInterval
MaxTSL

RO

CurrentMaxTransmitSignalLevelperinterval.

winlink1000OduPerfMonAirInterval
TSLThresh1Exceed

RO

NumberofsecondsTransmitSignalLevel
exceededtheTSL1thresholdperinterval.

winlink1000OduPerfMonAirInterval
BBERThresh1Exceed

RO

NumberofsecondsBackgroundBlockError
RatioexceededtheBBER1thresholdper
interval.

winlink1000OduPerfMonAirDayTabl
e

N/A Thistabledefines/keepstheaircountersofthe
lastmonth(inresolutionofdays).

winlink1000OduPerfMonAirDayEntr
y

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonAirDayIdx}

winlink1000OduPerfMonAirDayIdx

RO

ThistableisindexedperDaynumber.EachDay
isof15minutesandtheoldestis96.

winlink1000OduPerfMonAirDayMin
RSL

RO

CurrentMinReceivedLevelReferenceperDay.

winlink1000OduPerfMonAirDayMa
xRSL

RO

CurrentMaxReceivedLevelReferenceperDay.

winlink1000OduPerfMonAirDayRSL
Thresh1Exceed

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL1thresholdperDay.

RADWIN5000HPMPUserManual

Release3.5.50

C54

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet17of33)
OID

Type

Access

Name

Description

winlink1000OduPerfMonAirDayRSL
Thresh2Exceed

RO

NumberofsecondsReceiveSignalLevel
exceededtheRSL2thresholdperDay.

winlink1000OduPerfMonAirDayMin
TSL

RO

CurrentMinTransmitSignalLevelperDay.

winlink1000OduPerfMonAirDayMa
xTSL

RO

CurrentMaxTransmitSignalLevelperDay.

winlink1000OduPerfMonAirDayTSL
Thresh1Exceed

RO

NumberofsecondsTransmitSignalLevel
exceededtheTSL1thresholdperDay.

winlink1000OduPerfMonAirDayBBE
RThresh1Exceed

RO

NumberofsecondsBackgroundBlockError
RatioexceededtheBBER1thresholdperDay.

winlink1000OduPerfMonEthCurrTa
ble

N/A Thistabledefines/keepstheethernetcounters
ofthecurrent15mininterval.

winlink1000OduPerfMonEthCurrEn
try

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000OduPerfMonEthCurrRx
MBytes

1.3.6.1.4.1.4458.1000.1.6.7. Gauge
1.1

RO

CurrentRXMegaBytesstartingfromthe
present15minutesperiod.

winlink1000OduPerfMonEthCurrTx
MBytes

1.3.6.1.4.1.4458.1000.1.6.7. Gauge
1.2

RO

CurrentTransmitMegaBytesstartingfromthe
present15minutesperiod.

winlink1000OduPerfMonEthCurrEt
hCapacityThreshUnder

1.3.6.1.4.1.4458.1000.1.6.7. Gauge
1.3

RO

Thenumberoftimesthroughputwasbelow
thresholdinthepresent15minutesperiod.
Relevantforpointtopointsystems.

winlink1000OduPerfMonEthCurrHi
ghTrafficThreshExceed

1.3.6.1.4.1.4458.1000.1.6.7. Gauge
1.4

RO

Thenumberoftimesactualtrafficwasabove
thresholdinthepresent15minutesperiod.

winlink1000OduPerfMonEthCurrAc
tiveSeconds

1.3.6.1.4.1.4458.1000.1.6.7. Gauge
1.5

RO

ThenumberofsecondsinwhichRPLEthernet
swervicewasnotblockedinthepresent15
minutesperiod.

winlink1000OduPerfMonEthInterva
lTable

N/A Thistabledefines/keepstheethernetcounters
ofthelastday(inresolutionof15minintervals).

winlink1000OduPerfMonEthInterva
lEntry

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndexwinlink1000OduPerfMonEthIntervalIdx
}

winlink1000OduPerfMonEthInterva
lIdx

RO

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonEthInterva
lRxMBytes

RO

CurrentRXMegaBytesperinterval.

winlink1000OduPerfMonEthInterva
lTxMBytes

RO

CurrentTransmitMegaBytesperinterval.

winlink1000OduPerfMonEthInterva
lEthCapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdintheeachinterval.Relevantfor
pointtopointsystems.

winlink1000OduPerfMonEthInterva
lHighTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdintheeachinterval.

winlink1000OduPerfMonEthInterva
lActiveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedintheeachinterval.

winlink1000OduPerfMonEthDayTab
le

N/A Thistabledefines/keepstheethernetcounters
ofthelastmonth(inresolutionofdays).

winlink1000OduPerfMonEthDayEnt
ry

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonEthDayIdx}

winlink1000OduPerfMonEthDayIdx

RO

ThistableisindexedperDaynumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonEthDayRx
MBytes

RO

CurrentRXMegaBytesperday.

winlink1000OduPerfMonEthDayTx
MBytes

RO

CurrentTransmitMegaBytesperday.

RADWIN5000HPMPUserManual

Release3.5.50

C55

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet18of33)
OID

Type

Access

Name

Description

winlink1000OduPerfMonEthDayEth
CapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdeachday.Relevantforpointtopoint
systems.

winlink1000OduPerfMonEthDayHig
hTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdeachday.

winlink1000OduPerfMonEthDayAct
iveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedeachday.

winlink1000OduPerfMonTdmCurrTa
ble

N/A Thistabledefines/keepstheTDMcountersof
thecurrent15mininterval.

winlink1000OduPerfMonTdmCurrE
ntry

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000OduPerfMonTdmCurrA
ctiveSeconds

1.3.6.1.4.1.4458.1000.1.6.1
0.1.1

Gauge

RO

ParameterindicatingwhethertheTDMservice
wasactive.UnderTDMbackuplinkthe
parameterindicateswhetherthebackuplink
wasactive.

winlink1000OduPerfMonTdmInterv
alTable

N/A Thistabledefines/keepstheTDMcountersof
thelastday(inresolutionof15minintervals).

winlink1000OduPerfMonTdmInterv
alEntry

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndex
winlink1000OduPerfMonTdmIntervalIdx}

winlink1000OduPerfMonTdmInterv
alIdx

RO

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonTdmInterv
alActiveSeconds

RO

ParameterindicatingwhethertheTDMservice
wasactive.UnderTDMbackuplinkthe
parameterindicateswhetherthebackuplink
wasactive.

winlink1000OduPerfMonTdmDayTa
ble

N/A Thistabledefines/keepstheTDMcountersof
thelastmonth(inresolutionofdays).

winlink1000OduPerfMonTdmDayEn
try

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonTdmDayIdx}

winlink1000OduPerfMonTdmDayId
x

RO

ThistableisindexedperDaynumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000OduPerfMonTdmDayAc
tiveSeconds

RO

ParameterindicatingwhethertheTDMservice
wasactive.UnderTDMbackuplinkthe
parameterindicateswhetherthebackuplink
wasactive.

winlink1000OduPerfMonTxThresh1 1.3.6.1.4.1.4458.1000.1.6.2
0

Integer

RW WhentheTransmitpowerexceedsthis
thresholdaperformancemonitoringTSL1
counterisincremented.

winlink1000OduPerfMonRxThresh1 1.3.6.1.4.1.4458.1000.1.6.2
1

Integer

RW WhentheRXpowerexceedsthisthresholda
performancemonitoringRSL1counteris
incremented.

winlink1000OduPerfMonRxThresh2 1.3.6.1.4.1.4458.1000.1.6.2
2

Integer

RW WhentheRXpowerexceedsthisthresholda
performancemonitoringRSL2counteris
incremented.

winlink1000OduPerfMonBBERThres 1.3.6.1.4.1.4458.1000.1.6.2
h1
3

Integer

RW WhentheBBERexceedsthisthresholda
performancemonitoringBBERcounteris
incremented.Theunitsare1/10ofapercent.

winlink1000OduPerfMonEthCapacit 1.3.6.1.4.1.4458.1000.1.6.2
yThreshKbps
4

Integer

RW Whenthecurrentthroughputisbelowthis
thresholdthecorrespondingcounteris
incremented

winlink1000OduPerfMonHighTraffic 1.3.6.1.4.1.4458.1000.1.6.2
ThreshKbps
5

Integer

RW Whenthecurrenttrafficisabovethisthreshold
thencorrespondingcounterisincremented.

winlink1000OduAgnGenAddTrapExt 1.3.6.1.4.1.4458.1000.1.7.1. Integer


1

RADWIN5000HPMPUserManual

Release3.5.50

RW If'yes'ischosentheifIndexUnitSeverity
Time_TandAlarmIdfromthe
winlink1000OduAgnCurrAlarmTablewillbe
bindtotheendofeachprivatetrap.

C56

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet19of33)
OID

Type

winlink1000OduAgnGenSetMode

1.3.6.1.4.1.4458.1000.1.7.1. Integer
2

Access

Name

Description

RW Thisparameterisreservedtotheelement
managerprovidedwiththeproduct.

winlink1000OduAgnGenLocalConne
ctionMode

RW LocalConnection(Broadcast)Configuration
Mode.Optionsare:1SNMPReadWrite2
SNMPReadOnly.

winlink1000OduAgnNTPCfgTimeSer 1.3.6.1.4.1.4458.1000.1.7.2. IPAddress


verIP
1

RW IPaddressoftheserverfromwhichthecurrent
timeisloaded.

winlink1000OduAgnNTPCfgTimeOff 1.3.6.1.4.1.4458.1000.1.7.2. Integer


setFromUTC
2

RW OffsetfromCoordinatedUniversalTime
(minutes).Possiblevalues:1440..1440.

winlink1000OduAgnRealTimeAndD
ate

RW Thisparameterspecifiestherealtimeanddate
Format'YYYYMMDDHH:MM:SS'
(Hexadecimal).Adatetimespecification:
fieldoctetscontentsrange
112year
0..6553623month1..12
34day1..3145hour
0..2356minutes0..596
7seconds0..60(use60
forleapsecond)78deciseconds
0..9ForexampleTuesdayMay261992
at1:30:15PMEDTwouldbedisplayedas:
07c8051a0d1e0f00(1992526
13:30:15)

1.3.6.1.4.1.4458.1000.1.7.2. OctetString
3

winlink1000OduAdmNTPCfgTimeSe 1.3.6.1.4.1.4458.1000.1.7.2. DisplayString


rverIPv6
4

RW IPv6addressoftheserverfromwhichthe
currenttimeisloaded.

winlink1000OduAgnCurrAlarmLastC 1.3.6.1.4.1.4458.1000.1.7.3. Integer


hange
1

RO

winlink1000OduAgnCurrAlarmTable

N/A Thistableincludesthecurrentlyactivealarms.
WhenaRAISEDtrapissentanalarmentry
isaddedtothetable.WhenaCLEARtrapissent
theentryisremoved.

winlink1000OduAgnCurrAlarmEntry

N/A Entrycontainingthedetailsofacurrently
RAISEDtrap.INDEX{
winlink1000OduAgnCurrAlarmCounter}

winlink1000OduAgnCurrAlarmCoun 1.3.6.1.4.1.4458.1000.1.7.3. Integer


ter
2.1.1

RO

Arunningcounterofactivealarms.Thecounter
isincrementedforeverynewRAISEDtrap.Itis
clearedafteradevicereset.

winlink1000OduAgnCurrAlarmSeve
rity

1.3.6.1.4.1.4458.1000.1.7.3. Integer
2.1.2

RO

CurrentAlarmseverity.

winlink1000OduAgnCurrAlarmId

1.3.6.1.4.1.4458.1000.1.7.3. Integer
2.1.3

RO

UniqueAlarmIdentifier(combinesalarmtype
andinterface).ThesameAlarmIdisusedfor
RAISEDandCLEAREDalarms.

winlink1000OduAgnCurrAlarmIfInd
ex

1.3.6.1.4.1.4458.1000.1.7.3. Integer
2.1.4

RO

InterfaceIndexwherethealarmoccurred.
Alarmsthatarenotassociatedwithaspecific
interfacewillhavethefollowingvalue:65535.

winlink1000OduAgnCurrAlarmUnit

1.3.6.1.4.1.4458.1000.1.7.3. Integer
2.1.5

RO

Unitassociatedwiththealarm.

winlink1000OduAgnCurrAlarmTrapI 1.3.6.1.4.1.4458.1000.1.7.3. Integer


D
2.1.6

RO

IDoftheraisedtrapthatwassentwhenthis
alarmwasraised.

winlink1000OduAgnCurrAlarmTime 1.3.6.1.4.1.4458.1000.1.7.3. Integer


T
2.1.7

RO

Timestampofthisalarm.Thisnumberisin
secondsfromMidnightJanuary1st1970.

winlink1000OduAgnCurrAlarmText

RO

Alarmdisplaytext(sameasthetextinthesent
trap).

RO

Thiscounterindicatesthesizeofthe
winlink1000OduAgnLastEventsTable

1.3.6.1.4.1.4458.1000.1.7.3. DisplayString
2.1.8

winlink1000OduAgnLastEventsNum 1.3.6.1.4.1.4458.1000.1.7.4. Integer


ber
1

RADWIN5000HPMPUserManual

Release3.5.50

Thiscounterisinitializedto0afteradevice
resetandisincrementeduponeachchangein
thewinlink1000OduAgnCurrAlarmTable(either
anadditionorremovalofanentry).

C57

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet20of33)
OID

Type

Access

Name

Description

winlink1000OduAgnLastEventsTable

N/A Thistableincludesthelastevents.Whenatrap
issentanevententryisaddedtothetable.

winlink1000OduAgnLastEventsEntr
y

N/A Entrycontainingthedetailsoflasttraps.INDEX
{winlink1000OduAgnLastEventsIndex}

winlink1000OduAgnLastEventsInde
x

1.3.6.1.4.1.4458.1000.1.7.4. Integer
2.1.1

RO

Theindexofthetable

winlink1000OduAgnLastEventsSeve 1.3.6.1.4.1.4458.1000.1.7.4. Integer


rity
2.1.2

RO

CurrentTrapseverity.

winlink1000OduAgnLastEventsIfInd
ex

1.3.6.1.4.1.4458.1000.1.7.4. Integer
2.1.3

RO

InterfaceIndexwheretheeventoccurred.Traps
thatarenotassociatedwithaspecific
interfacewillhavethefollowingvalue:65535.

winlink1000OduAgnLastEventsTime 1.3.6.1.4.1.4458.1000.1.7.4. Integer


T
2.1.4

RO

Timestampofthistrap.Thisnumberisin
secondsfromMidnightJanuary1st1970.

winlink1000OduAgnLastEventsText

RO

Trapdisplaytext(sameasthetextinthesent
trap).

1.3.6.1.4.1.4458.1000.1.7.4. DisplayString
2.1.5

winlink1000OduAgnUsersTable

N/A SNMPuserstable.Eachuserisdefinedbyname
passwordandprofile.

winlink1000OduAgnUsersEntry

N/A SNMPuserstableentry.INDEX{
winlink1000OduAgnUsersIndex}

winlink1000OduAgnUsersIndex

1.3.6.1.4.1.4458.1000.1.7.5. Integer
1.1

RO

SNMPuserstableindex.

winlink1000OduAgnUsersUserNam
e

1.3.6.1.4.1.4458.1000.1.7.5. DisplayString
1.2

RW SNMPusersusernames.

winlink1000OduAgnUsersPassword

1.3.6.1.4.1.4458.1000.1.7.5. DisplayString
1.3

RW SNMPuserspasswords.

winlink1000OduAgnUsersProfile

1.3.6.1.4.1.4458.1000.1.7.5. Integer
1.4

RW SNMPusersprofile(1=Disabled2=ReadOnly
3=ReadWrite).

winlink1000OduAgnUsersLastAcces 1.3.6.1.4.1.4458.1000.1.7.5. Integer


sTime
1.5

RO

SNMPuserslastaccesstime.

winlink1000IduAdmProductType

RO

IDUconfigurationdescription.

winlink1000IduAdmHwRev

RO

IDUHardwareRevision.

winlink1000IduAdmSwRev

RO

IDUSoftwareRevision.

winlink1000OduAdmNumOfExterna
lAlarmIn

RO

Indicatesthenumberofcurrentlyavailable
ExternalAlarmInputs.

winlink1000OduAdmExternAlarmIn
Table

N/A ThisistheExternalAlarmInputstable.

winlink1000OduAdmExternAlarmIn
Entry

N/A Entrycontainingtheelementsofasingle
ExternalAlarmInput.INDEX{
winlink1000OduAdmExternAlarmInIndex}

winlink1000OduAdmExternAlarmIn
Index

RO

winlink1000OduAdmExternAlarmIn
Text

RW ThisfielddescribestheExternalAlarmInput.It
isanoptionalstringofnomorethan64
characterswhichwillbeusedintheevent
beingsentasaresultofachangeinthestatusof
theExternalAlarmInput.DEFVAL{Alarm
Description}

winlink1000OduAdmExternAlarmIn
AdminState

RW ThisvalueindicatesifthisExternalAlarmInput
isenabledordisabled.

winlink1000OduAdmExternAlarmIn
Status

RO

Thisvalueindicatesthecurrentstatusofthe
ExternalAlarmInput.

winlink1000IduAdmSN

RO

IDUSerialNumber

RADWIN5000HPMPUserManual

Release3.5.50

ThisvalueindicatestheindexoftheExternal
AlarmInputentry.

C58

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet21of33)
OID

Type

Access

Name

Description

winlink1000IduAdmIduDetectionM
ode

RW Theparameterdefineswhethertosend
EthernetframestodetectanIDU.Thevalid
writablevaluesare:userDisabled(3)
userEnabled(4).Achangerequiresaresetand
iseffectiveafterreset.

winlink1000IduAdmMountedTrunks

RO

NumberofmountedtrunksintheIDU

winlink1000IduAdmLicensedTrunks

RO

NumberofLicensedTrunksintheIDU

winlink1000IduAdmVlanSupported

RO

IdentifiesifthelocalIDUsupportsVLANtag/
untag

winlink1000IduAdmVlanEgressMod
e

RW VLANtag/untagegressvalues

winlink1000IduAdmVlanIngressMo
de

RW VLANtag/untagingressvalues

winlink1000IduAdmVlanDefaultPor
tVIDs

RW VLANtag/untagdefaultVLANidsforeachport
RightmostdigitisVlanpriority(06)otherdigits
composeVlanId(14094)

winlink1000IduAdmVlanLan1Untag
gedVIDs

RW VLANuntaggedVIDsforLAN1port

winlink1000IduAdmVlanLan2Untag
gedVIDs

RW VLANuntaggedVIDsforLAN2port

winlink1000IduAdmVlanSfpUntagg
edVIDs

RW VLANuntaggedVIDsforSfpport

winlink1000IduAdmVlanLan1Filtere
dVIDs

RW VLANfilteredVIDsforLAN1port

winlink1000IduAdmVlanLan2Filtere
dVIDs

RW VLANfilteredVIDsforLAN2port

winlink1000IduAdmVlanSfpFiltered
VIDs

RW VLANfilteredVIDsforSfpport

winlink1000IduAdmPortsConnectio
n

RW IDUportsconnectionbitmap.bit0LAN1
LAN2bit1SFPLAN1bit2SFPLAN2bit
values:0portsaredisconnected.1ports
areconnected.

winlink1000IduAdmVlanMode

RW LocalIDUVlanMode.

winlink1000IduAdmVlanMembersh
ipVIDs

RW VLANMembershipVLANIDslist.

winlink1000IduAdmVlanMembersh
ipPortsCode

RW VLANMembershipportscode.Eachvalue
representtherelation(bitmap)Betweenthe
suitableVIDtotheIDUports.bit0LAN1bit
1LAN2bit2SFPbitvalue0notmember
ofappropriateVIDbitvalue1memberof
appropriateVID

winlink1000IduAdmVlanMembersh
ipUntaggedHandle

RW VLANMembershipUntaggedframeshandling.
The3valuesrepresentingLAN1LAN2andSFP
accordingly.Foreachporttheoptionalvalues
are:1Discard2Tag3LeaveUnmodified

winlink1000IduAdmVlanMembersh
ipTagUntagged

RW VLANMembershipUntaggedframestagging.
The3valuesrepresentingLAN1LAN2andSFP
accordingly.Thevalueoneachportentry
representthetaggingvaluewhichisbuiltof:
VLANID&VLANPriority.

RADWIN5000HPMPUserManual

Release3.5.50

C59

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet22of33)
OID

Type

Access

Name

Description

winlink1000IduSrvDesiredTrunks

RW Requiredtrunksbitmap.Notethatthenumber
ofpossibletrunksthatcanbeconfiguredmay
varybasedontheIDUhardwareconfiguration
theselectedairinterfacerateandtherangeof
theinstallation.TheprovidedManager
applicationenablestheusertoselectonly
availableconfigurations.Achangeiseffective
immediatelyifappliedtoamasterunitandthe
linkisinservicemode.

winlink1000IduSrvServices

RO

ThisparameterisreservedtotheManager
applicationprovidedwiththeproduct.

winlink1000IduSrvActiveTrunks

RO

AbitmapdescribingthecurrentlyopenTDM
trunks.

winlink1000IduSrvAvailableTrunks

RO

AbitmapdescribingthenumberofTDMtrunks
thatcanbeopenedinthecurrentconfiguration.
ThevaluestakeintoaccounttheIDUhardware
configurationtheairrateandtheinstallation
range.

winlink1000IduSrvPossibleServices
Table

N/A IDUPossibleServicestable.

winlink1000IduSrvPossibleServices
Entry

N/A IDUServicestableentry.INDEX{
winlink1000IduSrvPossibleServicesIndex}

winlink1000IduSrvPossibleServicesI
ndex

RO

TableindexRateindexoftheairinterface.

winlink1000IduSrvPossibleTdmServi
ces

RO

Deprecatedparameter.Abitmapdescribingthe
TDMtrunksthatcanbeopenedinthe
correspondingAirRate.

winlink1000IduSrvPossibleEthServic
es

RO

Deprecatedparameter.Thisparameter
describesiftheEthernetServicecanbeopened
inthecorrespondingAirRate.Thevalidvalues
are:disabled(0)enabled(1).

winlink1000IduSrvRemainingRate

RO

CurrentEthernetbandwidthinbpsperairrate.

winlink1000IduSrvTrunkCost

RO

CostoftheTDMServiceinbps.

winlink1000IduSrvAvailServicesTabl
e

N/A ODUPossibleTDMServicestable.

winlink1000IduSrvAvailServicesEntr
y

N/A ODUTDMServicestableentry.INDEX{
winlink1000IduSrvAvailServicesIndex}

winlink1000IduSrvAvailServicesInde
x

RO

Tableindex.Theindexisthebitmaskofthe
TDMservice.

winlink1000IduSrvAvailServicesStat
e

RO

RepresentstheTDMserviceavailability.

winlink1000IduSrvAvailServicesMin
RateIdx

RO

Minimumrateindexoftheairinterfacewhich
maketheservicepossible.

winlink1000IduSrvAvailServicesMax
RateIdx

RO

Maximumrateindexoftheairinterfacewhich
maketheservicepossible.

winlink1000IduSrvAvailServicesRea
son

RO

InformationabouttheTDMServiceavailability.
NotApplicableiftheserviceisavailable.The
reasonsforTDMServiceunavailability:The
availablethroughputisn'tsufficientforService
demands;TheIDUHWdoesn'tsupportthe
service;ALinkPasswordmismatchwas
detected;Theexternalpulsetypedetectedis
improperforTDMservices;ASoftware
versionsmismatchwasdetected.ASymetric
TDDModeIsObligated.

winlink1000IduSrvEthActive

RO

RepresentstheEthernetserviceactivationstate.

winlink1000IduSrvEthAvailable

RO

RepresentstheEthernetserviceavailability
state.

RADWIN5000HPMPUserManual

Release3.5.50

C60

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet23of33)
OID

Type

Access

Name

Description

winlink1000IduSrvEthThroughput

RO

winlink1000IduSrvEthMaxInfoRate

RW Holdsthemaximumbandwidth(kbps)tobe
allocatedforEthernetservice.Valueofzero
meansthatEthernetserviceworksasbest
effort.Themaximumvalueisproductspecific.
Refertotheusermanual.

winlink1000IduSrvAvailableTrunksT
1

RO

winlink1000IduEthernetIfTable

N/A IDUEthernetInterfacetable.

winlink1000IduEthernetIfEntry

N/A IDUEthernetInterfacetableentry.INDEX{
winlink1000IduEthernetIfIndex}

winlink1000IduEthernetIfIndex

RO

IfIndexcorrespondingtothisInterface.

winlink1000IduEthernetIfAddress

RO

IDUMACaddress.

winlink1000IduEthernetNumOfLan
Ports

RO

NumberofLANinterfacesintheIDU.

winlink1000IduEthernetNumOfSfpP
orts

RO

ThenumberofSFPinterfacesintheIDU.

winlink1000IduEthernetSfpProperti
es

RO

SFPvenforproperties:VendorNamePNand
Revision.

winlink1000IduEthernetGbeSuppor
ted

CurrentavailableEthernetservicethroughputin
bps.

AbitmapdescribingtheTDMtrunksthatcanbe
openedunderT1configuration.Thevalues
takeintoaccounttheIDUhardware
configurationtheairrateandtheinstallation
range.

SupportedGigabitEthernetinIDU.

winlink1000IduEthernetOduInError
s

RO

winlink1000IduBridgeTpAging

RW Timeoutinsecondsforaging.Notethatforthis
parametertobeeffectivetheODUmustbe
configuredtoHUBmode.Achangeiseffective
immediately.

winlink1000IduTdmTxClockAvailStat
es

RO

winlink1000IduTdmTxClockDesiredS
tate

RW RequiredstateoftheTDMTransmitClock
Control.Achangeiseffectiveafterreactivation
oftheTDMservice.

winlink1000IduTdmTxClockActualSt
ate

RO

ActualstateoftheTDMTransmitClockControl.

winlink1000IduTdmMasterClockAva
ilOptions

RO

AvailableoptionsoftheTDMMasterClock
Controleachinputstatusisrepresentedbya
bit.Whentheoptionisavailablethebitvalue
is1.Whentheoptionisunavailablethebit
valueis0.Theavailableoptionsare:bit2=
Automaticbit3=Trunk#1bit4=Trunk#2bit
5=Trunk#3bit6=Trunk#4Whennooptions
areavailablethereturnedvalueis:1

winlink1000IduTdmMasterClockDes
ired

RW RequiredTDMMasterClock.Achangeis
effectiveafterreactivationoftheTDMservice.

winlink1000IduTdmMasterClockAct
ual

RO

winlink1000IduTdmConfigTable

N/A IDUTDMLinksConfigurationtable.

RADWIN5000HPMPUserManual

Release3.5.50

Thenumberofinboundpacketsthatcontained
errorspreventingthemfrombeingdeliverable
toahigherlayerprotocol.

AvailablestatesoftheTDMTransmitClock
Controleachinputstatusisrepresentedbya
bit.Whenthestateisavailablethebitvalueis
1.Whenthestateisunavailablethebitvalue
is0.Theavailablestatesare:bit2=
Transparentbit3=LocalLoopTimedbit4=
RemoteLoopTimedbit5=LocalInternalbit6
=RemoteInternal

ActualTrunkusedforTDMMasterClock.

C61

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet24of33)
OID

Type

Access

Name

Description

winlink1000IduTdmConfigEntry

N/A IDUTDMLinksConfigurationtableentry.
INDEX{winlink1000IduTdmConfigIndex}

winlink1000IduTdmConfigIndex

RO

Tableindex.

winlink1000IduTdmIfIndex

RO

Linkindexintheinterfacetable.

winlink1000IduTdmLineCoding

RW ThisparameterappliestoT1trunksonly.The
parametercontrolsthelinecoding.Settingthe
valuetoeachoftheindicesappliestoall.A
changeiseffectiveafterthenextopenofthe
TDMservice.

winlink1000IduTdmLoopbackConfig

RW Loopbackconfigurationtable.Eachofthe
trunkscanbesetNormalLineloopbackor
Reverselineloopback.Achangeiseffective
immediately.

winlink1000IduTdmLineStatus

RO

winlink1000IduTdmCurrentTable

N/A IDUTDMLinksStatisticstable.

winlink1000IduTdmCurrentEntry

N/A IDUTDMLinksStatisticstableentry.INDEX{
winlink1000IduTdmCurrentIndex}

winlink1000IduTdmCurrentIndex

RO

Tableindex(Sameas
winlink1000IduTdmLineIndex).

winlink1000IduTdmCurrentBlocks

RO

Numberofcorrectblockstransmittedtothe
line.

winlink1000IduTdmCurrentDrops

RO

Numberoferrorblockstransmittedtotheline.

winlink1000IduTdmCurrentTxClock

RW TDMTransmitClock.Achangeiseffectiveafter
reactivationoftheTDMservice.

winlink1000IduTdmCurrentBlocksHi
gh

RO

Highpartofthe64bitscounterCurrentBlocks

winlink1000IduTdmRemoteQual

RO

Estimatedaverageintervalbetweenerror
secondevents.Thevalidvaluesare12^31
whereavalueof1isusedtoindicatean
undefinedstate.

winlink1000IduTdmRemoteQualEva
l

RO

Estimatedaverageintervalbetweenerror
secondeventsduringevaluationprocess.The
validvaluesare12^31whereavalueof1is
usedtoindicateanundefinedstate.

winlink1000IduTdmSrvEval

RW EvaluatedTDMservicebitmask.Settingthis
parametertovaluethatisbiggerthanthe
activatedTDMservicebitmaskwillexecute
theevaluationprocessfor30seconds.Setting
thisparameterto0willstoptheevaluation
processimmediately.

winlink1000IduTdmBackupAvailabl
eLinks

RO

winlink1000IduTdmBackupTable

N/A IDUTDMLinksStatisticstable.

winlink1000IduTdmBackupEntry

N/A IDUTDMLinksStatisticstableentry.INDEX{
winlink1000IduTdmBackupIndex}

winlink1000IduTdmBackupIndex

RO

winlink1000IduTdmBackupMode

RW TDMbackupmode:EnableorDisablewhere
themainlinkistheairlinkortheexternallink.
Changeswillbeeffectiveimmediatly.

winlink1000IduTdmBackupCurrentA
ctiveLink

RO

winlink1000IduTdmJitterBufferSize

RW TDMJitterBufferSize.Thevaluemustbe
betweentheminimumandthemaximumTDM
JitterBufferSize.Theunitsare0.1x
millisecond.

RADWIN5000HPMPUserManual

Release3.5.50

Linestatus.

NumberofTDMbackuptrunks.

Tableindex.

TDMbackupcurrentactivelink:N/Aairlinkis
activeorexternallinkisactive.

C62

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet25of33)
OID

Type

Access

Name

Description

winlink1000IduTdmJitterBufferDefa
ultSize

RO

TDMJitterBufferDefaultSize.Theunitsare0.1
xmillisecond.

winlink1000IduTdmJitterBufferMinS
ize

RO

TDMJitterBufferMinimumSize.Theunitsare
0.1xmillisecond.

winlink1000IduTdmJitterBufferMax
Size

RO

TDMJitterBufferMaximumSize.Theunitsare
0.1xmillisecond.

winlink1000IduTdmJitterBufferSizeE
val

RW TDMJitterBufferSizeforevaluation.The
valuemustbebetweentheminimumandthe
maximumTDMJitterBufferSize.Theunitsare
0.1xmillisecond.

winlink1000IduTdmType

RW TDMType(Thevalueundefinedisreadonly).

winlink1000IduTdmTypeEval

RW TDMTypeforevaluation.

winlink1000IduTdmLineStatusStr

RO

Linestatus.

winlink1000IduTdmHotStandbySup
port

RO

IndicatesifHotStandbyissupported.

winlink1000IduTdmDesiredHotStan
dbyMode

RW DesiredHotStandbyMode.

winlink1000IduTdmHotStandbyOpe
rationStatus

RO

winlink1000IduTdmBackupLinkConf
iguration

RW Thecurrentconfigurationofthebackuplink.

winlink1000IduTdmLineInterfaceCo
nfiguration

RW TDMLineinterfaceconfiguration.

winlink1000IduTdmLineImpedance
Configuration

RW TDMlineimpedanceconfiguration(standardT1
100OhmnonStandardT1110Ohm)
ApplicableonlyforT1TDMtype.

winlink1000HbsAirState

RO

winlink1000HbsAirOpMode

RW HoldstheoperationmodeoftheHBS.

winlink1000HbsAirAvailTimeSlots

RO

Thisparameterholdsthenumberofavailable
timeslots(notinuse)intheairinterface.

winlink1000HbsAirSectorCbwSuppo
rtedStr

RO

Representsthechannelbandwidthwhichis
supportedbytheHBSandallconnectedHSUs.

winlink1000HbsAirCompressedMon

RO

HoldsHBSmonitordataincompressedformat:
HBSTrafficMonitorInBytes(4)OutBytes(4)
InFrames(4)OutFrames(4)HBSState(1)HBS
Freq(4)NumberofLinks(2)ECChange
Counter(4)CurrentRatio(2)TotalAirFrames
(4)HBSRxRateinKbps(4)HBSTxRateinKbps
(4)HBSRxRateinFps(4)HBSTxRateinFps
(4)HBSSetMode(1).

winlink1000HbsAirConfChanges

RO

16charactersthatrepresent16HSUs.Each
timeaconfigurationisbeenchangedincrement
therelevantcharacter.

winlink1000HbsAirConfTable

N/A HoldsthetableforallregisteredHSUsinthe
sector(16entries).

winlink1000HbsAirConfEntry

N/A HSUsconfigurationtableentry.INDEX{
winlink1000HbsAirConfIndex}

winlink1000HbsAirConfIndex

RO

winlink1000HbsAirConfUpMir

RW UplinkMIRtowardsspecificHSUinunitsof
kbps.

winlink1000HbsAirConfDownMir

RW DownlinkMIRtowardsspecificHSUinunitsof
kbps.

winlink1000HbsAirConfHsuName

RW HSUname.

winlink1000HbsAirConfHsuLocation

RW HSUlocation.

RADWIN5000HPMPUserManual

Release3.5.50

TheLinkActualStatus.

HoldsthestateoftheHBS.

HSUsconfigurationtableindex.

C63

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet26of33)
OID

Type

Access

Name

Description

winlink1000HbsAirConfDualAntTxM
ode

RW TransmissiontypewhenusingDualAntennaon
bothlink'ssides.spatialMultiplexingDiversity
(usingasinglespatialstream)andAuto
Selection(OMScontrol).

winlink1000HbsAirConfNumOfTs

RW Numberoftimeslotwhichareallocatedto
specificHSU.

winlink1000HbsAirConfGeoLocatio
n

RW Geographicdevicelocationinformat:latitude
longitude.

winlink1000HbsAirConfHsuType

RW HSUtype(1=Fixed2=Stationary3=Mobile4
=Transport)

winlink1000HbsAirConfHsuLevel

RW HSUlevel(1..4)

winlink1000HbsAirConfDesiredRate
Index

RW Therateindexofbothsidesofthelinktothis
HSU.

winlink1000HbsAirConfMacAddress

RO

winlink1000HbsAirConfNumOfTsUp

RW NumberofULtimeslotwhichareallocatedto
specificHSU.

winlink1000HbsAirLinkNumOfLinks

RO

winlink1000HbsAirLinkTable

N/A Holdsthetableforalllinksinthesector.

winlink1000HbsAirLinkEntry

N/A Linktableentry.INDEX{
winlink1000HbsAirLinkIndex}

winlink1000HbsAirLinkIndex

RO

HSUsconfigurationtableindex.

winlink1000HbsAirLinkHsuId

RO

HSUIDofspecificlink(ifregistered).
Unregisteredlinkshave1.

winlink1000HbsAirLinkState

RO

Holdsthestateofspecificlink.

winlink1000HbsAirLinkWorkingMod
e

RO

Indicatesthesubstatewithintheversion
compatibility.

winlink1000HbsAirLinkSessionId

RO

HoldstheSessionIDofthelink.

winlink1000HbsAirLinkHbsEstTput

RO

HoldstheEstimatedthroughputfromtheHBS
totheHSU.

winlink1000HbsAirLinkHsuEstTput

RO

HoldstheEstimatedthroughputfromtheHSU
totheHBS.

winlink1000HbsAirLinkRange

RO

Holdstherangeofspecificlink.

winlink1000HbsAirLinkHbsRss

RO

HoldstheRSSofspecificlink(HBSside).

winlink1000HbsAirLinkHbsRssBal

RO

HoldstheRSSBalanceofspecificlink(HBSside).
2:Radio2RSSismuchstrongerthanRadio1
RSS.1:Radio2RSSisstrongerthanRadio1
RSS.0:Radio2RSSisequaltoRadio1RSS.1
:Radio1RSSisstrongerthanRadio2RSS.2:
Radio1RSSismuchstrongerthanRadio2RSS.

winlink1000HbsAirLinkHsuRss

RO

HoldstheRSSofspecificlink(HSUside).

winlink1000HbsAirLinkHsuRssBal

RO

HoldstheRSSBalanceofspecificlink(HSUside).
2:Radio2RSSismuchstrongerthanRadio1
RSS.1:Radio2RSSisstrongerthanRadio1
RSS.0:Radio2RSSisequaltoRadio1RSS.1
:Radio1RSSisstrongerthanRadio2RSS.2:
Radio1RSSismuchstrongerthanRadio2RSS.

winlink1000HbsAirLinkHsuSerial

RO

HoldstheserialnumberforspecificHSU.

winlink1000HbsAirLinkTxOperMode

RO

HoldstheTXoperationmode.

winlink1000HbsAirHsuInBytes

RO

NumberofframesreceivedintheHSULanport.

winlink1000HbsAirHsuOutBytes

RO

NumberofframestransmittedfromtheHSU
Lanport.

winlink1000HbsAirHsuInFrames

RO

NumberofbytesreceivedintheHSULanport.

winlink1000HbsAirHsuOutFrames

RO

NumberofbytestransmittedfromtheHSULan
port.

RADWIN5000HPMPUserManual

Release3.5.50

HSUMACAddress.

Numberoflinksinthelinkstable.

C64

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet27of33)
OID

Type

Access

Name

Description

winlink1000HbsAirHsuMacAddress

RO

HSUMACAddress.

winlink1000HbsAirMaxTputDown

RO

MaxThroughputDownlink.

winlink1000HbsAirMaxTputUp

RO

MaxThroughputUplink.

winlink1000HbsAirLinkCompressed
Mon

RO

Holdsallthelinkinformationincompressed
binary(Bytes/octets).Fieldsincluded(sizein
bytes):LinkState(1)LinkWorking
Mode(1)SessionId(4)HBSEst.
Tput(4)HSUEst.Tput(4)HBSRss(1)
HBSRssBalance(1)HSURss(1)HSU
RssBalance(1)TxOperationMode(1)
HSUInBytes(4)HSUOutBytes(4)
HSUInFrames(4)HSUOutFrames(4)
HSUID(1bytes)HSURxRateInKbps(4)HSU
TxRateInKbps(4)HSURxRateInFps(4)HSU
TxRateInFps(4)PeakthroughputintheDL
direction(4)PeakthroughputintheUL
direction(4)Numberoflocalchangesat
HSU(1)ReservedforSmallCellSystems(1)HBS
Chain1Rss(1)HBSChain2Rss(1)HBSChain3
Rss(1)HSUChain1Rss(1)HSUChain2Rss(1)
HSUChain3Rss(1)CurrentRateIndex(2).

winlink1000HbsAirLinkCompressed
Static

RO

Holdsalltheconfigurationdataofthislinkin
compressedformat.HelpstheNMStogetinfo
regardingnewUnregisteredlinks.Fields
Included:SessionID(4bytes)HSUIPaddress
(4bytes)HSUName(32bytes)HSULocation
(32bytes)HSUSerialnumber(16bytes)HSU
MACAddress(12bytes)AirLinkRangeMax
ThroughputDown(4bytes)MaxThroughput
Up.(4bytes)CpacityLimit(4bytes)HSU
Antennatype(1byte)AggregateCapacity(4
bytes)

winlink1000HbsAirCpeCapacityLimi
t

RO

CapacityLimitinKilobitpersecond.

winlink1000HbsAirLinkAntennaTyp
e

RO

HSUExternalAntennaType:Monopolaror
Bipolar.

winlink1000HbsAirHsuRxRateInKbp
s

RO

HSURxRateinKbps.

winlink1000HbsAirHsuTxRateInKbp
s

RO

HSUTxRateinKbps.

winlink1000HbsAirHsuRxRateInFps

RO

HSUTxRateinFps.

winlink1000HbsAirHsuTxRateInFps

RO

HSUTxRateinFps.

winlink1000HbsAirLinkPeakTputDo
wn

RO

PeakthroughputintheDLdirection(kbps).

winlink1000HbsAirLinkPeakTputUp

RO

PeakthroughputintheULdirection(kbps).

winlink1000HbsAirLinkUtilDownSec
RelMill

RO

Theaveragetimepercentage(inthousandths)
outoftheBTSDLcapabilitythatwasusedfor
transmittingdatatotheSU.

winlink1000HbsAirLinkUtilUpSecRel
Mill

RO

Theaveragetimepercentage(inthousandths)
outoftheBTSULcapabilitythatwasusedfor
receivingdatafromtheSU.

winlink1000HbsAirLinkUtilDownAll
ocRelMill

RO

Thetimepercentage(inthousandths)relative
totheSUDLallocationthatwasusedfor
transmittingdatatotheSU.

winlink1000HbsAirLinkUtilUpAllocR
elMill

RO

Thetimepercentage(inthousandths)relative
totheSUULallocationthatwasusedfor
receivingdatafromtheSU.

RADWIN5000HPMPUserManual

Release3.5.50

C65

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet28of33)
OID

Type

Access

Name

Description

winlink1000HbsAirLinkUtilDownTra
fficKbps

RO

Averagedatathroughput(ExportedinKbps)
transmittedintheDLtowardstheSUduring
thelastsecond.

winlink1000HbsAirLinkUtilUpTraffic
Kbps

RO

Averagedatathroughput(ExportedinKbps)
receivedintheULfromtheSUduringthelast
second.

winlink1000HbsAirLinkUtilCompres
sedMon

RO

Onestringthatholdsthe6Utilizationperlink
values:DownSecRel(2bytes)UpSecRel
(2bytes)DownAllocRel(4bytes)UpAllocRel
(4bytes)DownTraffic(4bytes)UpTraffic(4
bytes).

winlink1000HbsAirComboSwitchSec
torFreqBandId

RW SwitchFrequencybandforthewholesector.

winlink1000HbsAirGeoAzimuth

RW Geographicsectorazimuthindegrees*10.

winlink1000HbsAirGeoBeamwidth

RW Geographicsectorbeamwidthindegrees*10.

winlink1000HbsAirMaxDistanceMet
ersMobility

RW Maximumdistanceinmeters.UsedbyMobility
linksonly.

winlink1000HbsAirComboSwitchSec
torFreqBandIdStr

RW SwitchFrequencybandforthewholesector
overridingsomeoftheComboparameters.

winlink1000HbsAirTimeSlotAllocati
onBitmap

RW TimeSlotsAllocationBitmapfortheentire
sector(HexValue).

winlink1000HbsAirAvailTimeSlotsU
p

RO

Thisparameterholdsthenumberofavailable
ULtimeslots(notinuse)intheairinterface.

winlink1000HbsAirDownUtilMill

RO

SectorAirInterfaceutilizationintheDownlink
direction(thousandths).Averagetime
percentageoutoftheentireBTSDLcapability
thatwasusedfortransmittingdatatoallthe
SUs.

winlink1000HbsAirUpUtilMill

RO

SectorAirInterfaceutilizationintheUplink
direction(thousandths).Theaveragenumber
oftimeslotsthatwereusedintheUL(byallthe
links)outoftheentirenumberoftimeslots.

winlink1000HbsAirDownTrafficKbps

RO

Averagedatathroughput(expressedinKbps)
transmittedintheDLtowardsalltheSUs
duringthelastsecond.

winlink1000HbsAirUpTrafficKbps

RO

Averagedatathroughput(expressedinKbps)
receivedintheULfromalltheSUsduringthe
lastsecond.

winlink1000HbsAirCompressedMon
Sec

RO

Onestringthatholdsthe4UtilizationperSector
values:DownUtil(2bytes)UpUtil(2bytes)
DownTraffic(4bytes)UpTraffic(4bytes).

winlink1000HbsAirDelayVsTputOpt

RW Delayvs.Throughputoptimizationtype:1=
Delaysensitivity2=Throughputoptimized

winlink1000HbsAirUCBPMinCS

RW MinimalcontentionslotlengthusedforUCBP
algorithm(inms.)between520ms.

winlink1000HbsAirUCBPSharingPer
centage

RW SharingpercentageusedbyUCBPalgorithm(15
75)

winlink1000HbsBridgeAgingTime

RW Timeoutinsecondsforaging.

winlink1000HbsBridgeVlanTable

N/A HoldsthebridgeVlanoperationstowardsallthe
registeredHSUs.

winlink1000HbsBridgeVlanEntry

N/A HBSbridgeVlantableentry.INDEX{
winlink1000HbsBridgeVlanIndex}

winlink1000HbsBridgeVlanIndex

RO

winlink1000HbsBridgeVlanIngress

RW HBSbridgeVlaningress.

winlink1000HbsBridgeVlanEgress

RW HBSbridgeVlanegress.

winlink1000HbsBridgeVlanFilterIn

RW HBSbridgeVlanfilterin.

RADWIN5000HPMPUserManual

Release3.5.50

HBSbridgeVlantableindex.

C66

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet29of33)
OID

Type

Access

Name

Description

winlink1000HbsBridgeVlanFilterOut

RW HBSbridgeVlanfilterout.

winlink1000HbsBridgeVlanDoubleT
ag

RW HBSbridgeVlandoubletag.

winlink1000HbsBridgeVlanDefaultI
d

RW HBSbridgeVlandefaultid.

winlink1000HbsBridgeMembership
Table

N/A Holdsthebridgemembershiprelationsforall
theregisteredHSUs.

winlink1000HbsBridgeMembership
Entry

N/A HBSbridgemembershiptableentry.INDEX{
winlink1000HbsBridgeMembershipIndex}

winlink1000HbsBridgeMembershipI
ndex

RO

winlink1000HbsBridgeMembership
State

RW HBSbridgemembershipstatebitmap.Eachbit
representsBlocked/Openedrelation
(membership)betweentwoHSUs.Blocked=0
(bit)Opened=1(bit).Thisobjectholdsthe
relationto32HSUs.

winlink1000HbsBridgeMembership
State2nd

RW HBSbridgemembershipstatebitmap.Eachbit
representsBlocked/Openedrelation
(membership)betweenHSUandLAN/Stackport
oftheHBS.Blocked=0(bit)Opened=1(bit).
Only2bitsareused.

winlink1000HbsBridgeFloodOverloa
dProtect

RW Floodoverloadprotection1Enabled2
Disabled.

winlink1000HbsServiceCommandSt
r

RW AbilitytoperformspecialcommandintheHBS.
Format(string):OperationIndexSession
Param1Param2....|ParamNTheindexand
SessionIDcanbeunitingtooneparameter.On
registeredHSUitisHSUIDandonUnregistered
itisSessionID.

winlink1000HbsServiceVlanTable

N/A HoldstheVlanoperationstowardsallthe
registeredHSUs.

winlink1000HbsServiceVlanEntry

N/A HBSserviceVlantableentry.INDEX{
winlink1000HbsServiceVlanIndex}

winlink1000HbsServiceVlanIndex

RO

winlink1000OduServiceVlanTblTag

RW TheVIDtobeusedwhenaddingTAGoradding
Provider

winlink1000OduServiceVlanTblPri

RW TheVlanpriority07tobeusedwhenadding
TAGoraddingProvider

winlink1000OduServiceVlanTblMaj
orMode

RW TheVlanmajormode

winlink1000OduServiceVlanTblEgre
ssMode

RW TheVlanmodeintheEgressdirection

winlink1000OduServiceVlanTblIngr
essMode

RW TheVlanmodeintheIngressdirection

winlink1000OduServiceVlanTblEgre
ssFilter1

RW VLANFilter1VID

winlink1000OduServiceVlanTblEgre
ssFilter2

RW VLANFilter2VID

winlink1000OduServiceVlanTblEgre
ssFilter3

RW VLANFilter3VID

winlink1000OduServiceVlanTblEgre
ssFilter4

RW VLANFilter4VID

winlink1000OduServiceVlanTblUnta
gFilteredBitmap

RW Represents(inbitmap)iftoUntagaframeafter
itisfiltered(Egressdirection)[4bitsrepresent4
filters].

RADWIN5000HPMPUserManual

Release3.5.50

HBSbridgemembershiptableindex.

HBSserviceVlantableindex.

C67

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet30of33)
OID

Type

Access

Name

Description

winlink1000OduServiceVlanTblProv
iderTPID

RW HoldstheProviderTPIDthatisusedinall
provideroperations.

winlink1000HbsServiceQoSMode

RW QualityofServicemode.

winlink1000HbsServiceQoSVlanQGr
oupsStr

RW FrameclassificationaccordingtoVLANpriority
(all4groupsseparatedbycomma).

winlink1000HbsServiceQoSDiffserv
QGroupsStr

RW FrameclassificationaccordingtoDiffserv(all4
groupsseparatedbycomma).

winlink1000HbsServiceQoSMaxRtQ
uePct

RO

winlink1000HbsServiceQoSTable

N/A HoldstheQoSoperationstowardsallthe
registeredHSUs.

winlink1000HbsServiceQoSEntry

N/A HBSserviceQoStableentry.INDEX{
winlink1000HbsServiceQoSIndex}

winlink1000HbsServiceQoSIndex

RO

winlink1000HbsServiceQoSConfAd
minState

RW QoSadministrativestate.Thevalidvaluesare:
enabled(1)disabled(2).

winlink1000HbsServiceQoSConfUp
QueMir

RW PrivateMIRforeachQoSgroupoftheUplink
direction(4valuesseparatedbycomma).

winlink1000HbsServiceQoSConfUp
QueWeight

RW WeightinpercentforeachQoSgroupofthe
Uplinkdirection(4valuesseparatedbycomma).

winlink1000HbsServiceQoSConfDo
wnQueMir

RW PrivateMIRforeachQoSgroupoftheDownlink
direction(4valuesseparatedbycomma).

winlink1000HbsServiceQoSConfDo
wnQueWeight

RW WeightinpercentforeachQoSgroupofthe
Downlinkdirection(4valuesseparatedby
comma).

winlink1000HbsServiceQoSUpTtlMs

RW TTLinmilisecondforeachQoSgroupofthe
Uplinkdirection(4valuesseparatedbycomma).

winlink1000HbsServiceQoSDownTtl
Ms

RW TTLinmilisecondforeachQoSgroupofthe
Downlinkdirection(4valuesseparatedby
comma).

winlink1000HbsServiceQoSUpStrict

RW StrictQOSBooleanindicationforeachQOS
groupoftheUplinkdirection(4values
separatedbycomma).

winlink1000HbsServiceQoSDownStr
ict

RW StrictQOSBooleanindicationforeachQOS
groupoftheDownlinkdirection(4values
separatedbycomma).

winlink1000HbsServiceMobilitySup
ported

RO

MobilitySupport(1=Notsupported2=
Supported3Transportsupported)

winlink1000HbsServiceMaxNumOf
HSUs

RO

HoldsthemaximumnumberofregisteredHSUs
intheHBS.

winlink1000HbsPerfMonThreshTabl
e

N/A Holdstheperformancemonitorthresholds
towardsalltheregisteredHSUs.

winlink1000HbsPerfMonThreshEntr
y

N/A HBSperformancemonitorthresholdtableentry.
INDEX{winlink1000HbsPerfMonThreshIndex}

winlink1000HbsPerfMonThreshInde
x

RO

winlink1000HbsPerfMonTxThresh1

RW HBSperformancemonitortransmitpower
threshold.

winlink1000HbsPerfMonRxThresh1

RW HBSperformancemonitorreceivepower
threshold1.

winlink1000HbsPerfMonRxThresh2

RW HBSperformancemonitorreceivepower
threshold2.

winlink1000HbsPerfMonBBERThres
h1

RW HBSperformancemonitorBBERthreshold.

RADWIN5000HPMPUserManual

Release3.5.50

MaximalpercentforRTandNRTqueues.

HBSserviceQoStableindex.

HBSperformancemonitorthresholdtable
index.

C68

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet31of33)
OID

Type

Access

Name

Description

winlink1000HbsPerfMonEstThroug
hputThreshKbps

RW HBSperformancemonitorestimated
throughputThreshold.

winlink1000HbsPerfMonHighTraffic
ThreshKbps

RW HBSperformancemonitorhightrafficthreshold.

winlink1000HbsPerfMonAirGenCur
rTable

N/A Thistabledefines/keepstheethernetcounters
ofthecurrent15mininterval.

winlink1000HbsPerfMonAirGenCur
rEntry

N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}

winlink1000HbsPerfMonAirGenCur
rRxMBytes

RO

CurrentRXMegaBytesstartingfromthe
present15minutesperiod.(Representsthe
LANtrafficRXdirectiontowardtheHSU)

winlink1000HbsPerfMonAirGenCur
rTxMBytes

RO

CurrentTransmitMegaBytesstartingfromthe
present15minutesperiod.(Representsthe
LANtrafficTXdirectionfromtheHSU)

winlink1000HbsPerfMonAirGenCur
rEthCapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdinthepresent15minutesperiod.
Relevantforpointtopointsystems.

winlink1000HbsPerfMonAirGenCur
rHighTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdinthepresent15minutesperiod.

winlink1000HbsPerfMonAirGenCur
rActiveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
swervicewasnotblockedinthepresent15
minutesperiod.

winlink1000HbsPerfMonAirGenInte
rvalTable

N/A Thistabledefines/keepstheethernetcounters
ofthelastday(inresolutionof15minintervals).

winlink1000HbsPerfMonAirGenInte
rvalEntry

N/A ThisisanentryintheIntervalTable.INDEX
{ifIndex
winlink1000HbsPerfMonAirGenIntervalIdx}

winlink1000HbsPerfMonAirGenInte
rvalIdx

RO

Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000HbsPerfMonAirGenInte
rvalRxMBytes

RO

CurrentRXMegaBytesperinterval.
(RepresentstheLANtrafficRXdirectiontoward
theHSU).

winlink1000HbsPerfMonAirGenInte
rvalTxMBytes

RO

CurrentTransmitMegaBytesperinterval.
(RepresentstheLANtrafficTXdirectionfrom
theHSU)

winlink1000HbsPerfMonAirGenInte
rvalEthCapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdintheeachinterval.Relevantfor
pointtopointsystems.

winlink1000HbsPerfMonAirGenInte
rvalHighTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdintheeachinterval.

winlink1000HbsPerfMonAirGenInte
rvalActiveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedintheeachinterval.

winlink1000HbsPerfMonAirGenDay
Table

N/A Thistabledefines/keepstheethernetcounters
ofthelastmonth(inresolutionofdays).

winlink1000HbsPerfMonAirGenDay
Entry

N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000HbsPerfMonAirGenDayIdx
}

winlink1000HbsPerfMonAirGenDay
Idx

RO

ThistableisindexedperDaynumber.Each
intervalisof15minutesandtheoldestis96.

winlink1000HbsPerfMonAirGenDay
RxMBytes

RO

CurrentRXMegaBytesperday.(Represents
theLANtrafficRXdirectiontowardtheHSU)

winlink1000HbsPerfMonAirGenDay
TxMBytes

RO

CurrentTransmitMegaBytesperday.
(RepresentstheLANtrafficTXdirectionfrom
theHSU)

winlink1000HbsPerfMonAirGenDay
EthCapacityThreshUnder

RO

Thenumberoftimesthroughputwasbelow
thresholdeachday.Relevantforpointtopoint
systems.

RADWIN5000HPMPUserManual

Release3.5.50

C69

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet32of33)
OID

Type

Access

Name

Description

winlink1000HbsPerfMonAirGenDay
HighTrafficThreshExceed

RO

Thenumberoftimesactualtrafficwasabove
thresholdeachday.

winlink1000HbsPerfMonAirGenDay
ActiveSeconds

RO

ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedeachday.

winlink1000HsuAirState

1.3.6.1.4.1.4458.1000.4.1.1

Integer

RO

HoldsthestateoftheHSU.

winlink1000HsuAirLinkState

1.3.6.1.4.1.4458.1000.4.1.2

Integer

RO

HoldsthestateoftheHSUlink.

winlink1000HsuAirHsuId

1.3.6.1.4.1.4458.1000.4.1.3

Integer

RO

HoldstheHSUIDassentbytheHBS.

winlink1000HsuAirLocalDeregister

1.3.6.1.4.1.4458.1000.4.1.5

Integer

RW PerformsLocalHSUDeregistrationwhenonly
whenthelinkisoff.

winlink1000HsuAirRemoteCompres 1.3.6.1.4.1.4458.1000.4.1.6
sedMon

OctetString

RO

HoldsalltheconfigurationdataofTheHBSin
compressedformat.FieldsIncluded:Rss(1
byte)RssBalance(1byte)Est.Tput(4
bytes)InBytesofthewholesector(4bytes)
OutBytesofthewholesector(4bytes)In
Framesofthewholesector(4bytes)Out
Framesofthewholesector(4bytes)Max
ThroughputDownLink(4bytes)Max
ThroughputUpLink(4bytes)RxRateInKbpsof
thewholesector(4bytes)TxRateInKbpsof
thewholesector(4bytes)RxRateInFpsofthe
wholesector(4bytes)TxRateInFpsofthe
wholesector(4bytes)PeakThroughputinthe
DLdirectioninKbps(4bytes)PeakThroughput
intheULdirectioninKbps(4bytes)TxRatio(2
bytes)Chain1Rss(1byte)Chain2Rss(1byte)
Chain3Rss(1byte)CurrentRateIndex(2bytes)

winlink1000HsuAirRemoteCompres 1.3.6.1.4.1.4458.1000.4.1.7
sedStatic

DisplayString

RO

HoldsalltheconfigurationdataoftheHBSina
compressedformat.HelpstheNMStogetinfo
regardingnewUnregisteredlinks.Fields
Included:Location(32bytes)IPaddress(8
bytesinhexa)Subnetmask(8bytesinhexa)
HBSAntennatype(1byte)HBSAgentVersion
(4bytes)HBSName(32bytes)

winlink1000HsuAirRssThreshSync

Integer

RW HSUswillbesychnornizedimmediatelyifRSSis
betterthanthreshold.

1.3.6.1.4.1.4458.1000.4.1.8

winlink1000HsuAirAlignmentCmd

RW 1StartAlignmentprocessandinitializetheGIRO
2Evaluatecurrentmanualangle3Finish
Alignmentprocess4AbortAlignmentprocess

winlink1000HsuAirAlignmentStatus

RO

AntennaAlignmentstatus:1N/A(fornonBSA
products)1ISS(scanningforHBS)2CSA
(SynctoHBSwaitingforEvaluationcommand)
3Bidirectionallink4Evaluate2x25
Evaluate3x36AlignmentFinished.

winlink1000HsuAirAlignment3x3Ste
p

RO

StepnumberoutoftotalstepsinThroughput
evaluationfor3x3scenario.

winlink1000HsuAirAlignment3x3Tot
alSteps

RO

TotalstepsinThroughputevaluationfor3x3
scenario.

winlink1000HsuAirAlignmentEvalTo

RW Evaluationtimeout.

winlink1000HsuAirAlignmentLastRe
portManualAngle

RO

Theangleoftheantenna.Usedinthealignment
process.

winlink1000HsuAirAlignmentLastRe
portTputUpSector

RO

Expectedthroughputforthewholesectorinthe
Uplinkdirectioninthisangle.

winlink1000HsuAirAlignmentLastRe
portTputDownSector

RO

Expectedthroughputforthewholesectorinthe
Downlinkdirectioninthisangle.

winlink1000HsuAirAlignmentLastRe
portRssChain1

RO

RSSonchain1.

winlink1000HsuAirAlignmentLastRe
portRssChain2

RO

RSSonchain2.

RADWIN5000HPMPUserManual

Release3.5.50

C70

PrivateMIBParameters

TableC3:PrivateMIBParametersHSU(Sheet33of33)
OID

Type

Access

Name

Description

winlink1000HsuAirAlignmentLastRe
portRssChain3

RO

RSSonchain3.

winlink1000HsuAirAlignmentLastRe
portMcsIndexUp

RO

MCSindexofthelinkintheuplinkdirection.

winlink1000HsuAirAlignmentLastRe
portMcsIndexDown

RO

MCSindexofthelinkinthedownlinkdirection.

winlink1000HsuAirAlignmentLastRe
portState

RO

StateoftheEvaluation1Finishedsuccessfully
2PartialEvaluation(TimeoutExceeded)3
EvaluationAborted(TimeoutExceeded)4
Evaluationaborted(UnstableAntenna)5
Evaluationaborted(SyncLost)6Evaluation
aborted(Externalcommand)7Evaluating.

winlink1000HsuServiceCommandSt 1.3.6.1.4.1.4458.1000.4.2.1
r

DisplayString

RW AbilitytoperformspecialcommandintheHSU.
Format(string):OperationParam1Param2....|
ParamN.

winlink1000HsuServiceHsuType

1.3.6.1.4.1.4458.1000.4.2.2

Integer

RW HSUtype(1=Fixed2=Stationary3=Mobile4
=Transport)

winlink1000HsuServiceHsuLevel

1.3.6.1.4.1.4458.1000.4.2.3

Integer

RW HSUlevel(1..4)

winlink1000HsuEthernetPoESuppor 1.3.6.1.4.1.4458.1000.4.3.1. Integer


ted
1

RO

IndicatedifthisHSUhasspecialportforPoE
devices.

winlink1000HsuEthernetPoETempe
rature

1.3.6.1.4.1.4458.1000.4.3.1. Integer
2

RO

Holdsthetemperature(Celsius)ofthePOE
component.

winlink1000HsuEthernetPoEEquCo
nsumption

1.3.6.1.4.1.4458.1000.4.3.1. Integer
3

RO

Holdstheconsumptionoftheconnected
equipment(milliampere).

winlink1000HsuEthernetPoEEquVol 1.3.6.1.4.1.4458.1000.4.3.1. Integer


tage
4

RO

Holdsthevoltageoftheconnectedequipment
(Volt).

winlink1000GeneralTrapDescription 1.3.6.1.4.1.4458.1000.100.1 DisplayString

RO

Trap'sDescription.UsedforTrapparameters.

winlink1000GeneralTrapSeverity

1.3.6.1.4.1.4458.1000.100.2 Integer

RO

Trap'sSeverity.UsedforTrapparameters.

winlink1000GeneralCookie

1.3.6.1.4.1.4458.1000.100.3 DisplayString

RW ReservedfortheManagerapplicationprovided
withtheproductusedforsavinguser
preferencesaffectingODUoperation.

winlink1000GeneralEcChangesCoun 1.3.6.1.4.1.4458.1000.100.4 Integer


ter

RO

winlink1000GeneralTelnetSupport

1.3.6.1.4.1.4458.1000.100.5 Integer

RW Enable/DisableTelnetprotocol.

winlink1000GeneralWISupport

1.3.6.1.4.1.4458.1000.100.6 Integer

RW Enable/DisableWebInterfaceprotocol.
MandatoryDisabledNooptiontoenablethe
feature.MandatoryEnabledNooptionto
disablethefeature.

winlink1000GeneralSNMPSupport

1.3.6.1.4.1.4458.1000.100.7 Integer

RW Enable/DisableSNMPprotocols

RADWIN5000HPMPUserManual

Release3.5.50

Thiscounterisinitializedto0afteradevice
resetandisincrementeduponeachelement
constantwriteoperationviaSNMPorTelnet.

C71

MIBTraps

MIBTraps
General
EachODUcanbeconfiguredwithupto10differenttrapdestinations.Whenthelinkis
operational,eachODUsendstrapsoriginatingfrombothSiteAandSiteB.
ThesourceIPaddressofthetrapisthesendingODU.Thetraporiginatorcanbeidentifiedby
thetrapCommunitystringorbythetrapdescriptiontext.
Eachtrapcontainsatrapdescriptionandadditionalrelevantinformationsuchasalarm
severity,interfaceindex,timestampandadditionalparameters.

TrapParameters
TableC4:MIBTraps(Sheet1of8)
Name

ID

Severity

Description

trunkStateChanged

normal

IndicatesachangeinthestateofoneoftheTDM
trunks.Raisedbybothsidesofthelink.Contains3
parameters:1Description:TDMInterface%n%x2
%n:Isthetrunknumber3%x:Isthealarmtypeand
canbeoneofthefollowing:NormalAISLOSLoopback

linkUp

normal

Indicatesthattheradiolinkisup.Containsasingle
parameterwhichisitsdescription:1Description:
RadioLinkSynconchannel%nGHz.%nIsthechannel
frequencyinGHz.

linkDown

critical

Indicatesthattheradiolinkisdown.Containsasingle
parameterwhichisitsdescription:1Description:
RadioLinkOutofSync.Thereasonis:%s.%sIsthe
reason.

detectIDU

normal

IndicatesthattheIDUwasdetected.Raisedbyboth
sidesofthelink.Containsasingleparameterwhichis
itsdescription:1Description:IDUofType%swas
Detected.%sIsthetypeoftheIDU.

disconnectIDU

major

IndicatesthattheIDUwasdisconnected.Raisedby
bothsidesofthelink.Containsasingleparameter
whichisitsdescription:1Description:IDU
Disconnected.

mismatchIDU

major

IndicatesamismatchbetweentheIDUs.Raisedbythe
masteronly.Containsasingleparameterwhichisits
description:1Description:IDUsMismatch:OneSide
is%sandtheOtheris%s.%sIsthetypeoftheIDU.

openedServices

normal

Indicatesthatserviceswereopened.Raisedbythe
masteronly.Contains3parameters:1Description:
%n2outof%n1RequestedTDMTrunkshavebeen
Opened2%n1:IstherequestednumberofTDM
truncks3%n2:IstheactualnumberofTDMtrunks
thatwereopened

closedServices

normal

Indicatesthatserviceswereclosed.Raisedbythe
masteronly.Containsasingleparameterwhichisits
description:1Description:TDMServicehasbeen
closed.Thereasonis:%s.%sIsthereason.

incompatibleODUs

critical

IndicatesthattheODUsareincompatible.Containsa
singleparameterwhichisitsdescription:1
Description:IncompatibleODUs.

incompatibleIDUs

10

major

IndicatesthattheIDUsareincompatible.Containsa
singleparameterwhichisitsdescription:1
Description:IncompatibleIDUs.

incompatibleOduIdu

11

major

IndicatesthattheODUandIDUareincompatible.
Containsasingleparameterwhichisitsdescription:1
Description:TheIDUcouldnotbeloaded.Thereasonis:
%s.%sIstheincompatibilitytype.

RADWIN5000HPMPUserManual

Release3.5.50

C72

MIBTraps

TableC4:MIBTraps(Sheet2of8)
Name

ID

Severity

Description

probingChannel

12

normal

IndicatesthattheODUismonitoringradaractivity.
Containsasingleparameterwhichisitsdescription:1
Description:Monitoringforradaractivityonchannel%n
GHz.%nisthechannelfrequencyinGHz.

radarDetected

13

normal

Indicatesthatradaractivitywasdetected.Containsa
singleparameterwhichisitsdescription:1
Description:Radaractivitywasdetectedin%son
channel%nGHz.%sIsthesitename.%nIsthe
channelfrequencyinGHz.

transmittingOnChannel

14

normal

IndicatesthattheODUistransmittingonchannel.
Containsasingleparameterwhichisitsdescription:1
Description:Transmittingonchannel%nGHz.%nIsthe
channelfrequencyinGHz.

scanningChannels

15

normal

IndicatesthattheODUisscanningchannels.Containsa
singleparameterwhichisitsdescription:1
Description:Channelscanninginprogress.

incompatiblePartner

16

critical

Indicatesthatconfigurationproblemwasdetectedand
thatlinkinstallationisrequiredinordertofixit.
Containsasingleparameterwhichisitsdescription:1
Description:Configurationproblemdetected.Link
installationrequired.

timeClockSet

17

normal

IndicatesthattheODUtimeclockwasset.Containsa
singleparameterwhichisitsdescription:1
Description:Thetimewassetto:%p.%pIsthedate
andtime.

configurationChanged

18

normal

IndicatesthattheODUrecoveredfromanerrorbut
thereareconfigurationchanges.Containstwo
parameters:1Description:Configurationchanged.
Errorcodeis:%n.2%nnumber.

hssOpStateChangedToINU

19

normal

IndicatesthattheHSSoperatingstatewaschangedto
INUtype.Containsasingleparameterwhichisits
description:1Description:HSSoperatingstatewas
changedto:INU.

hssOpStateChangedToHSM

20

normal

IndicatesthattheHSSoperatingstatewaschangedto
HSMtype.Containsasingleparameterwhichisits
description:1Description:HSSoperatingstatewas
changedto:HSM.

hssOpStateChangedToHSC

21

normal

IndicatesthattheHSSoperatingstatewaschangedto
HSCtype.Containsasingleparameterwhichisits
description:1Description:HSSoperatingstatewas
changedto:HSC_DT/HSC_CT.

vlanModeActive

22

normal

IndicatestononVLANPCthatafter2minutesthe
systemwillsupportonlyVLANtagonmanagement
interface.Containsasingleparameterwhichisits
description:1Description:VLANModeisactive.Non
VLANtrafficwillbeblockedin2minutes.

spectrumAnalysis

23

normal

IndicatesthattheODUisinSpectrumAnalysismode.
Containsasingleparameterwhichisitsdescription:1
Description:Spectrumanalysisinprogress.

hbsHsuDeregisteredOffline

24

normal

IndicatesthataHSUwasderegisteredoffline(outof
link)

hbsHsuDeregisteredSuccessfully

25

normal

IndicatesthataHSUwasderegisteredsuccessfully

hbsHsuRegisteredSuccessfully

26

normal

IndicatesthataHSUwasregisteredsuccessfully

hbsHsuRegistrationFailed

27

normal

Indicatesthatregistrationhasfailed

hbsHsuViolatedState

28

normal

Indicates(ontheHBSside)thataHSUisisviolatedstate

hsuViolatedState

29

normal

Indicates(ontheHSUside)thattheHSUisisviolated
state

hbsUnregisteredSynchronizedHsu

30

normal

IndicatesanunregisteredHSUhasbeensynchronized.

RADWIN5000HPMPUserManual

Release3.5.50

C73

MIBTraps

TableC4:MIBTraps(Sheet3of8)
Name

ID

Severity

hbsUnregisteredUnsynchronizedHsu

31

normal

Description
IndicatesanunregisteredHSUlostsynchronization.

cableQuality

32

normal

1Gbpsrateisnotsupportedduetobadlinequality.

httpAuthentication

33

normal

HTTPAuthenticationFailure.

telnetAuthentication

34

normal

TelnetAuthenticationFailure.

tdmServiceAlarm

100

major

IndicatesthatTDMServiceisinalarmstate.Containsa
singleparameterwhichisitsdescription:1
Description:TDMServiceAlarm.

ethServiceClosed

101

major

IndicatesthatEthernetServiceisclosed.Containsa
singleparameterwhichisitsdescription:1
Description:EthernetServiceisclosed.

ethServiceNotPermitted

102

major

IndicatesthatEthernetServiceisnotpermitted.
Containsasingleparameterwhichisitsdescription:1
Description:AvalidIDUcouldnotbedetectedat%s.
Pleasecheckyourconfiguration.%sIstheLocalSite
nameorRemoteSitenameorbothsidesoftheLink.

encryptionAlarm

103

major

Indicatesanencryptionkeymismatch.Containsa
singleparameterwhichisitsdescription:1
Description:EncryptionStatusFailed.NoServicesare
available.

changeLinkPasswordAlarm

104

major

Indicatesthatafailurehasoccurredwhileattemptingto
changetheLinkPassword.Containsasingleparameter
whichisitsdescription:1Description:Failedto
changetheLinkPasswordat/on:%s.%sIstheLocal
SitenameorRemoteSitenameorbothsidesofthe
Link.

externalAlarmInPort1Alarm

105

major

Thetrapissenteverytimeanalarmoccursinthe
ExternalAlarmInputofport#1.Containsasingle
parameterwhichisitsdescription:1Description:
ExternalAlarm1<UserText>Alarm.

externalAlarmInPort2Alarm

106

major

Thetrapissenteverytimeanalarmoccursinthe
ExternalAlarmInputofport#2.Containsasingle
parameterwhichisitsdescription:1Description:
ExternalAlarm2<UserText>Alarm.

bitFailedAlarm

107

major

Thetrapissentifthereisnowaytorecoverfromthe
situation.Containstwoparameters:1Description:
ODUpowerupbuiltintestfailed.Errorcodeis:%n2
%nnumber

wrongConfigurationLoadedAlarm

108

major

Thetrapissentifthereisawaytorecoverfromthe
situation.Containstwoparameters:1Description:
Wrongconfigurationloaded.Errorcodeis:%n2%n
number

lanPort1DisconnectedAlarm

109

major

IndicatestheLANport1statuschangedto
disconnected.Containsasingleparameterwhichisits
description:1Description:LANport1statuschanged
todisconnected.

lanPort2DisconnectedAlarm

110

major

IndicatestheLANport2statuschangedto
disconnected.Containsasingleparameterwhichisits
description:1Description:LANport2statuschanged
todisconnected.

mngPortDisconnectedAlarm

111

major

Indicatesthemanagementportstatuschangedto
disconnected.Containsasingleparameterwhichisits
description:1Description:Managementportstatus
changedtodisconnected.

externalAlarmInPort3Alarm

112

major

Thetrapissenteverytimeanalarmoccursinthe
ExternalAlarmInputofport#3.Containsasingle
parameterwhichisitsdescription:1Description:
ExternalAlarm3<UserText>Alarm.

RADWIN5000HPMPUserManual

Release3.5.50

C74

MIBTraps

TableC4:MIBTraps(Sheet4of8)
Name

ID

Severity

Description

externalAlarmInPort4Alarm

113

major

Thetrapissenteverytimeanalarmoccursinthe
ExternalAlarmInputofport#4.Containsasingle
parameterwhichisitsdescription:1Description:
ExternalAlarm4<UserText>Alarm.

swVersionsMismatchFullCompatibilityAlarm

114

warning

ThetrapissentifSWversionsmismatchwithfulllink
functionality.Containsasingleparameterwhichisits
description:1Description:Softwareversions
mismatchfulllinkfunctionality

swVersionsMismatchRestrictedCompatibilityAlarm

115

minor

ThetrapissentifSWversionsmismatchwithrestricted
linkfunctionality.Containsasingleparameterwhichis
itsdescription:1Description:Softwareversions
mismatchrestrictedlinkfunctionality

swVersionsMismatchSoftwareUpgradeRequired

116

major

ThetrapissentifSWversionsmismatchandSW
upgradeisrequired.Containsasingleparameter
whichisitsdescription:1Description:Software
versionsmismatchSoftwareupgraderequired

swVersionsIncompatible

117

critical

ThetrapissentifSWversionsareincompatible.
Containsasingleparameterwhichisitsdescription:1
Description:SWVersionsincompatible

hssMultipleSourcesDetectedAlarm

118

major

Indicatesthatmultiplesyncpulsesourceswere
detected.Containsasingleparameterwhichisits
description:1Description:HSSmultiplesyncsources
weredetected.

hssSyncToProperSourceStoppedAlarm

119

major

Indicatesthatsynchronizationtoapropersyncpulse
sourcewasstopped.Containsasingleparameter
whichisitsdescription:1Description:HSSsyncpulse
Down.Thereasonis:%s.%sIsthereasonforthe
syncdown.

hssSyncPulseDetectedAlarm

120

major

IndicatesthatHSSadditionalsyncpulsewasdetected.
Containsasingleparameterwhichisitsdescription:1
Description:HSSadditionalsyncpulsewasdetected.

tdmBackupAlarm

121

major

IndicatesthattheTDMbackuplinkwasactivated.
Containsasingleparameterwhichisitsdescription:1
Description:TDMbackupalarmbackuplinkwas
activated.

linkLockUnauthorizedRemoteODU

122

major

IndicatesthattheremoteODUisunauthorized.
Containsasingleparameterwhichisitsdescription:1
Description:UnauthorizedremoteODUconnection
rejected.

linkLockUnauthorizedODU

123

major

IndicatesthattheODUisunauthorized.Containsa
singleparameterwhichisitsdescription:1
Description:UnauthorizedODUconnectionrejected.

hotStandbyAlarm

124

major

Indicatesthatthehotstandbysecondarylinkwas
activated.Containsasingleparameterwhichisits
description:1Description:SecondaryLinkIsActive.

sfpInsertion

126

normal

IndicatesthatadevicewasinsertedtoSFPPort

sfpPort1DisconnectedAlarm

127

major

IndicatestheSFPport1statuschangedto
disconnected.Containsasingleparameterwhichisits
description:1Description:SFPport1statuschanged
todisconnected.

ringRplStateActiveAlarm

128

major

RPLstatechangedtoActive.

desiredRatioCanNotBeAppliedAlarm

129

normal

IndicatesDesiredUL/DLRAtioCanNotBeApplied.

cbwMismatch

130

major

IndicatesthataChannelBandwidthmismatchwas
detected.Containstwoparameters:1Description:
ChannelBandwidthMismatch:onesideis%n0MHzand
theotheris%n1MHz.%n0isthelocalChannel
BandwidthvalueinMHz.%n1istheremoetChannel
BandwidthvalueinMHz.

gpsNotSynchronized

131

major

IndicatesthattheGPSisnotsynchronizedwith
satellites.Pulsesareselfgenerated.

RADWIN5000HPMPUserManual

Release3.5.50

C75

MIBTraps

TableC4:MIBTraps(Sheet5of8)
Name

ID

Severity

Description

pdTooHighDueCbwLimitations

132

major

Indicatesthatlinkcannotbeestablishedbecauselink
rangeistoolargeforchannelbandwidth.

hbsEncryptionAlarm

133

major

Indicatesanencryptionkeymismatch.Containsa
singleparameterwhichisitsdescriptionincludingthe
HSU'sname

hbsEhServiceClosedToHsu

134

major

Indicatesanencryptionkeymismatch.Containsa
singleparameterwhichisitsdescriptionincludingthe
HSU'sname

hbsUnsynchronizedHsuAlarm

135

warning

IndicatesaregisteredHSUlostsynchronization.

hbsInactiveHbsAlarm

136

major

IndicatesHBSisInActive.

incompatibleHsu

137

critical

IndicatesthattheHSUisnotcompatibletoHBS.
Containsasingleparameterwhichisitsdescription:1
Description:IncompatibleODUs.

hsuUnsupportedBeacon

138

warning

IndicatesanunsupportedbeaconhasarrivedatHSU

lanPortDisconnectedAlarm

139

major

IndicatestheLANportstatuschangedtodisconnected.
Containsasingleparameter,whichisitsdescription:
1Description:LANportstatuschangedto
disconnected.

poePortDisconnectedAlarm

140

major

IndicatesthePOEportstatuschangedtodisconnected.
Containsasingleparameter,whichisitsdescription:
1Description:POEportstatuschangedto
disconnected.

poePowerConsumptionAlarm

141

major

IndicatesthePOEPowerConsumptionisaboveallowed
maximum.
Containsasingleparameter,whichisitsdescription:
1Description:POEconsumptionaboveallowed
maximum.portclosed.

hobupFaultyStateAlarm

149

major

ThisAlarmwillindicatethattheHotBackupmoduleisin
faultystate.
1Description:HotBackupfaultdetected:%sunit.
%sPrimaryOrSecondaryUnit

gpsOverCurrentAlarm

150

major

IndicatestheGPSAntennacurrentconsumptionis
aboveallowedmaximum.
Containsasingleparameter,whichisitsdescription:
1Description:GPSAntennacurrentconsumption
aboveallowedmaximum.GPSclosed.

gpsCommunicationFailiureAlarm

151

major

IndicatestheGPSdataisn'treceived.
Containsasingleparameter,whichisitsdescription:
1Description:GPSCommunicationfailiure.

temperatureThresholdAlarm

152

major

Indicatestheboardtemperatureisaboveallowed
maximum.
Containsasingleparameter,whichisitsdescription:
1Description:GPSAntennacurrentconsumption
aboveallowedmaximum.GPSclosed.

localRouterDiscoveryStatus

153

major

ThisAlarmwillindicatethatwehavenoconnection
withTracksiderouter.
1Description:MacLearningUpdatedetected
disconnectionwithTracksiderouter%s
%sDefaultgatewayIP

TrackRouterDiscoveryStatus

154

major

ThisAlarmwillindicatethatwehavenoconnection
withTracksiderouter.
1Description:MacLearningUpdatedetected
disconnectionwithTracksiderouter%s
%sDefaultgatewayIP

btsTargetUnreachable

156

major

ThisAlarmwillindicatethatwehavenoconnection
withBtsdesiredtarget.
1Description:TNCdetecteddisconnectionwiththe
BTStarget%s
%sDefaultgatewayIP

RADWIN5000HPMPUserManual

Release3.5.50

C76

MIBTraps

TableC4:MIBTraps(Sheet6of8)
Name

ID

Severity

Description

tdmServiceClear

200

major

IndicatesthatTDMServicefaultiscleared.Containsa
singleparameterwhichisitsdescription:1
Description:TDMServiceNormal.

ethServiceOpened

201

normal

IndicatesthatEthernetServicehasbeenopened.
Containsasingleparameterwhichisitsdescription:1
Description:EthernetServicehasbeenopened.

encryptionClear

203

normal

IndicatesthatencryptionisOK.Containsasingle
parameterwhichisitsdescription:1Description:
EncryptionStatusNormal.

changeLinkPasswordClear

204

normal

IndicatesthattheLinkPasswordwaschanged
successfully.Containsasingleparameterwhichisits
description:1Description:LinkPasswordhasbeen
changedat/on:%s.%sIstheLocalSitenameor
RemoteSitenameorbothsidesoftheLink.

externalAlarmInPort1Clear

205

normal

ThisTrapissenteverytimeanExternalAlarmInputfault
ofport#1iscleared.Containsasingleparameter
whichisitsdescription:1Description:ExternalAlarm
1<UserText>AlarmCleared.

externalAlarmInPort2Clear

206

normal

ThisTrapissenteverytimeanExternalAlarmInputfault
ofport#2iscleared.Containsasingleparameter
whichisitsdescription:1Description:ExternalAlarm
2<UserText>AlarmCleared.

lanPort1Clear

209

normal

IndicatestheLANport1statuschangedtoconnected.
Containstwoparameters:1Description:LANport1
statuschangedtoconnected%s2%sIstheEth.
mode(speed&duplex)

lanPort2Clear

210

normal

IndicatestheLANport2statuschangedtoconnected.
Containstwoparameters:1Description:LANport2
statuschangedtoconnected%s.2%sIstheEth.
mode(speed&duplex).

mngPortClear

211

normal

Indicatesthemanagementportstatuschangedto
connected.Containstwoparameters:1Description:
Managementportstatuschangedtoconnected%s2
%sIstheEth.mode(speed&duplex)

externalAlarmInPort3Clear

212

normal

ThisTrapissenteverytimeanExternalAlarmInputfault
ofport#3iscleared.Containsasingleparameter
whichisitsdescription:1Description:ExternalAlarm
3<UserText>AlarmCleared.

externalAlarmInPort4Clear

213

normal

ThisTrapissenteverytimeanExternalAlarmInputfault
ofport#4iscleared.Containsasingleparameter
whichisitsdescription:1Description:ExternalAlarm
4<UserText>AlarmCleared.

swVersionsMatchFullCompatibilityClear

214

normal

ThetrapissentifSWversionsmatch.Containsasingle
parameterwhichisitsdescription:1Description:
SoftwareVersionscompatible

swVersionsMatchRestrictedCompatibilityClear

215

normal

ThetrapissentifSWversionsmatchandlink
functionalityisnotrestricted.Containsasingle
parameterwhichisitsdescription:1Description:
SoftwareVersionscompatible

swVersionsMatchSoftwareUpgradeRequiredClear

216

normal

ThetrapissentifSWversionsmatchandSWupgradeis
successful.Containsasingleparameterwhichisits
description:1Description:SoftwareVersions
compatible

swVersionsCompatibleClear

217

normal

ThetrapissentifSWversionscompatibleContainsa
singleparameterwhichisitsdescription:1
Description:SoftwareVersionscompatible

hssMultipleSourcesDisappearedClear

218

normal

Indicatesthatmultiplesyncpulsesourcesdisappeared.
Containsasingleparameterwhichisitsdescription:1
Description:HSSmultiplesyncpulsesources
disappeared.

RADWIN5000HPMPUserManual

Release3.5.50

C77

MIBTraps

TableC4:MIBTraps(Sheet7of8)
Name

ID

Severity

Description

hssSyncToProperSourceAchievedClear

219

normal

IndicatesthatsynchronizationtoaproperSyncsource
wasachieved.Containsasingleparameterwhichisits
description:1Description:HSSsyncpulseUp.

hssSyncPulseDisappearedClear

220

normal

IndicatesthatHSSadditionalsyncpulsedisappeared.
Containsasingleparameterwhichisitsdescription:1
Description:HSSadditionalsyncpulsewasdisappeared.

tdmBackupClear

221

normal

IndicatesthattheTDMmainlinkwasactivated.
Containsasingleparameterwhichisitsdescription:1
Description:TDMmainlinkwasactivated.

linkLockAuthorizedRemoteODU

222

normal

IndicatesthattheremoteODUisauthorized.Contains
asingleparameterwhichisitsdescription:1
Description:AuthorizedremoteODUconnection
accepted.

linkLockAuthorizedODU

223

normal

IndicatesthattheODUisauthorized.Containsasingle
parameterwhichisitsdescription:1Description:
AuthorizedODUconnectionpermitted.

linkAuthenticationDisabled

224

normal

IndicatesthattheLinkLockisdisabled.Containsa
singleparameterwhichisitsdescription:1
Description:LinkAuthenticationhasbeendisabled.

hotStandbyClear

225

normal

IndicatesthatthePrimaryLinkWasActivated.Contains
asingleparameterwhichisitsdescription:1
Description:PrimaryLinkIsActive.

sfpExtraction

226

normal

IndicatesthatadevicewasextractedfromSFPPort

sfpPort1Clear

227

normal

IndicatestheSFPport1statuschangedtoconnected.
Containstwoparameters:1Description:SFPport1
statuschangedtoconnected%s2%sIstheEth.
mode(speed&duplex)

compatibleIdus

228

normal

IndicatesthattheODUhasidentifiedcompatibleIdus
onbothsidesofthelink.

desiredRatioCanNotBeAppliedClear

229

normal

IndicatesCurrentUL/DLRatioIsEqualToDesiredRatio.

cbwMatch

230

normal

IndicatesthataChannelBandwidthmatchwas
detected.Containsasingleparameterwhichisits
description:1ChannelBandwidthvalueinMHz.

switchCbwAndChannel

231

normal

IndicatesthatthesystemisswitchingChannel
Bandwidthandchannelfrequency.Containstwo
parameters:1SwitchingtoChannelBandwith%n0
MHzandtochannel%n1GHz.

ringRplStateIdle

232

normal

RPLstatechangedtoIdle.

ringEthServiceStatus

233

normal

IndicatesEthernetservice'sstateblocked\unblocked.
Containsasingleparameter:1Description:Ethernet's
state(blocked\unblocked)

ringFirstRpmReceived

234

normal

Ringapplication:innonRPLlinkindicatesfirstfroma
specificRPLwasreceived.Containsasingleparameter:
1Description:RPM'sVLANID

ringEthernetSrviceUnblockedTO

235

normal

Ringapplication:innonRPLlinkEthernetserviceis
unblockedduetoRPMtimeout.

gpsSynchronized

236

normal

IndicatesthattheGPSissynchronizedwithsatellites.

hbsEncryptionClear

237

normal

IndicatesthatencryptionisOK.Containsasingle
parameterwhichisitsdescriptionincludingtheHSU's
name

hbsEhServiceOpenedToHsu

238

normal

IndicatesthatencryptionisOK.Containsasingle
parameterwhichisitsdescriptionincludingtheHSU's
name

hbsSynchronizedHsuAlarm

239

normal

IndicatesaregisteredHSUissynchronized.

hbsActiveHbs

240

normal

IndicateswhenHBShasbeenactivated.

switchCBW

241

normal

SwitchingChannelBandwidth.

changeRatio

242

normal

HBSTxratiohaschanged.

RADWIN5000HPMPUserManual

Release3.5.50

C78

MIBTraps

TableC4:MIBTraps(Sheet8of8)
Name

ID

Severity

Description

lanPortClear

243

normal

IndicatestheLANportstatuschangedtoconnected.
Containstwoparameters:
1Description:LANportstatuschangedtoconnected
%s
2%sIstheEth.mode(speed&duplex)

poePortClear

244

normal

IndicatesthePOEportstatuschangedtoconnected.
Containstwoparameters:
1Description:POEportstatuschangedtoconnected
%s
2%sIstheEth.mode(speed&duplex)

poePowerConsumptionClear

245

normal

IndicatesthePOEpowerconsumptionisvalid.
Containstwoparameters:
1Description:POEconsumptionwithinlimits.portis
opened.
2%sIstheEth.mode(speed&duplex)

incompatibleHbsHsu

246

normal

IncompatibleHBS/HSUsoftwareversionsnoservice.

mobilityLinkOff

247

normal

MobilityLinkcannotbeestablisheddueto:
1TheHBSdoesnotsupportMobility
2LackofresourcesintheHBSforHSUlevel

enterLocalConnection

248

normal

EnteringLocalConnection(Broadcast)Mode.

hobupActiveStateFaultyClear

249

normal

ThisclearalarmwillindicatethattheHotBackupunitis
inactivestate.
Containsasingleparameter,whichisitsdescription:
1Description:HotBackup%sunitactivated.
%sPrimaryOrSecondaryUnit

hobupStandbyState

250

normal

Containsasingleparameter,whichisitsdescription:
1Description:HotBackupinStandbystate:%sunit.
%sPrimaryOrSecondaryUnit

gpsOverCurrentClear

251

normal

IndicatestheGPSAntennacurrentconsumptionisvalid.

temperatureThresholdClear

252

normal

Indicatestheboardtemperatureisvalid.

localRouterDiscoverySucceed

253

normal

Indicatedthewesucceededtodiscovertrainrouterinip
%sMACaddress%s
%sTrainIP
%sTrainMACAddress

TrackRouterDiscoverySucceed

254

normal

Indicatedthewesucceededtodiscovertrackrouterin
ip%sMACaddress%s
%sTrainIP
%sTrainMACAddress

btsTargetIsReachable

257

normal

Indicatedthewesucceededtoestablishconnection
withtheBtsdesiredtarget(%s)
%sTargetIP

RADWINManagerTraps
TheRADWINManagerapplicationissuestrapstoindicatevariousevents.Thesetrapsare
shownintheRADWINManagerrEventsLog.
AlistofTrapMessagesasdisplayedbytheRADWINManagerisshowninTable 124.

RADWIN5000HPMPUserManual

Release3.5.50

C79

AppendixD:

RFExposure
Theantennasusedforthefollowingtransmittersmustbeinstalledsoastoprovidea
minimumseparationdistancefrombystandersasspecifiedinthefollowingtables:
TableD1:SafetyDistancesforRADWIN5000HPMPFCCandICProducts
Frequency
Band
[GHz]

FCCID

ICID

Antennagain Min.Safety
Distance[cm]
[dBi]

5.8

Q3KRW5XMOD

5100ARW5XMOD

32

354

5.8

Q3KRW5XMOD

5100ARW5XMOD

29

251

5.8

Q3KRW5XMOD

5100ARW5XMOD

24

141

5.8

Q3KRW5XMOD

5100ARW5XMOD

16

60

5.8

Q3KRW5XMOD

5100ARW5XMOD

Allsectors

20

5.3/5.4

Q3KRW5XMOD

5100ARW5XMOD

Allgains

20

4.9

Q3KRW5XMOD

5100ARW5XMOD

32,29

96

4.9

Q3KRW5XMOD

5100ARW5XMOD

24

72

4.9

Q3KRW5XMOD

5100ARW5XMOD

16,15.5

31

4.9

Q3KRW5XMOD

5100ARW5XMOD

14,13

24

4.9

Q3KRW5XMOD

5100ARW5XMOD

12,11

20

2.4

Q3KRW24MOD

5100ARW24MOD

20

53

2.4

Q3KRW24MOD

5100ARW24MOD

17.5

43

2.4

Q3KRW24MOD

5100ARW24MOD

9,8,6.3

20

RADWIN5000HPMPUserManual

Release3.5.50

D1

RFExposure

TableD2:SafetyDistancesforRADWIN5000HPMPETSIProducts
FrequencyBand
[GHz]

5.8/5.3/5.4/2.4

Antennagain
[dBi]

Min.Safety
Distance
[cm]

Allgains

20

RADWIN5000HPMPUserManual

Release3.5.50

D2

AppendixE:

SettingAntennaParameters
AntennaIssues
ThechoiceofTxPower,antennagainandcableloss(betweentheradioandtheantenna)
determinestheEIRPandisaffectedbysuchconsiderationsasradiolimitationsandregulatory
restrictions.
Beforeproceedingtoantennainstallationdetails,thefollowingbackgroundinformation
shouldbeconsidered:

AboutSingleandDualAntennas
EachRADWIN5000HPMPODUismadeoftworadiotransceivers(radios).Theradiosmake
useofalgorithmsthatutilizebothSpatialMultiplexingandDiversityresultinginenhanced
capacity,rangeandlinkavailability.Thenumberofantennas(i.e.radios)usedisdetermined
byuserconfigurationandbyautomaticsystemdecisions,explainedbelow.

DualAntennasattheHBSandanHSU
Whenusingdualantennasatbothsites(singlebipolarantennaortwomounipolarantennas)
youcanchoosebetweenSpatialMultiplexingModeandDiversityMode.

SpatialMultiplexingMode
Underthismode,thesystemdoublesthelinkcapacity.Atthesametime,itkeepsthesame
rateandmodulationperradioaswasusedwithsingleantenna,thusincreasingcapacity,
rangeandavailability.
ForexamplewithadualantennaRADWIN5000HPMPcantransmitatmodulationof64QAM
andFECof5/6andgetanairrateof130Mbps,comparedto65Mbpswithsingleantenna.
Toworkinthismode,eachantennaportmustbeconnectedtoanantenna,theRSSlevelin
bothreceiversshouldbebalancedandaminimalseparationbetweentheantennasmustbe
maintained.(Forexample,byusingdualpolarizationantennasacrosspolarizationseparation
isattained).
RADWIN5000HPMPUserManual

Release3.5.50

E1

SingleAntennasatBothSites

UponselectingAntennaTypeasDual,RADWIN5000HPMPautomaticallyselectsthismode
anddoublestheairrates.
RADWINManagerindicatesacaseofunbalancedRSSbetweenthetwoantennasintheHBS
panels.

DiversityMode
DiversityModeusestwoantennastoimprovethequalityandreliabilityofthelink.Often,
thereisnotaclearlineofsight(LOS)betweentransmitterandreceiver.Insteadthesignalis
reflectedalongmultiplepathsbeforefinallybeingreceived.
Eachsuchbouncecanintroducephaseshifts,timedelays,attenuations,andeven
distortionsthatcandestructivelyinterferewithoneanotherattheapertureofthereceiving
antenna.Antennadiversityisespeciallyeffectiveatmitigatingthesemultipathsituations.
Thisisbecausemultipleantennasaffordareceiverseveralrecordingsofthesamesignal.Each
antennawillbeexposedtoadifferentinterferenceenvironment.Thus,ifoneantennais
undergoingadeepfade,itislikelythatanotherhasasufficientsignal.Collectivelysucha
systemcanprovidearobustlink.
Antennadiversityrequiresantennaseparationwhichispossiblebyusingadualpolarization
antennaorbytwospatiallyseparatedantennas.
UseDiversityinsteadofSpatialMultiplexinginthefollowingsituations:

WhenthesystemcannotoperateinSpatialMultiplexingMode
Whenoneofthereceivershashighinterferencecomparedtothesecondreceiver(i.e.
thesystemisunbalanced)
WhenyouachievehighercapacityinDiversityModethaninSpatialMultiplexingMode
WhenhighrobustnessisofimportanceandthecapacityofDiversityModeissufficient
(upto25Mbpsfullduplex)

SingleAntennasatBothSites
ByselectingasingleantennaattheHBSandHSU,theODUsoperatewithasingleradiothatis
connectedtotheANT1connector.Thesecondradioisautomaticallyshutdown.

SingleatOneSite,DualAntennasattheOther
InthismodeoneofthesitesusestheODUwithasingleantennawhiletheothersiteusesthe
ODUwithadualantenna.
Theadvantagesinthismodeincomparisontousingasingleantennainbothsitesare
doubledtotalTxPowerandadditionalpolarizationand/orspacediversity(dependingonthe
polarizationofinstalledantennas).
Theairratesusedinthismodearesameaswhenusingsingleantennasinbothsites.

RADWIN5000HPMPUserManual

Release3.5.50

E2

SingleatOneSite,DualAntennasattheOther

Table E1summarizesthesituation:(SM=SpatialMultiplexing)
TableE1:SpatialMultiplexingDiversitysettings
Numberof
Antennas

Mode

SiteA SiteB

MaxFull
Duplex
Capacity

SM

50Mbps

Diversity

25Mbps

25Mbps

25Mbps

25Mbps

SiteAandBmaybeHBSorHSU.
TheratesusedbyRADWIN5000HPMPareshowninTable E2below:
TableE2:RADWIN5000HPMPAirrates
AirRate[Mbps]
Antenna

Modulation

FEC

Single

BPSK

1/2

6.5

13.5

Single

QPSK

1/2

13

27

Single

QPSK

3/4

19.5

40.5

Single

16QAM

1/2

26

54

Single

16QAM

3/4

39

81

Single

64QAM

2/3

52

108

Single

64QAM

3/4

58.5

121.5

Single

64QAM

5/6

65

135

Dual

BPSK

1/2

13

27

Dual

QPSK

1/2

26

54

Dual

QPSK

3/4

39

81

Dual

16QAM

1/2

52

108

Dual

16QAM

3/4

78

162

Dual

64QAM

2/3

104

216

RADWIN5000HPMPUserManual

20MHz
CBW

40MHz
CBW

Release3.5.50

E3

ConsiderationsforChangingAntennaParameters

TableE2:RADWIN5000HPMPAirrates(Continued)
AirRate[Mbps]
Antenna

Modulation

FEC

Dual

64QAM

3/4

117

243

Dual

64QAM

5/6

130

270

20MHz
CBW

40MHz
CBW

ConsiderationsforChangingAntenna
Parameters
Let:
maxAvailableTxPowerdenotethemaximumTxPowerpracticallyavailablefromanODU.(It
appearsasTxPowerperRadio.)
maxRegEIRPdenotethemaximumEIRPavailablebyregulation.Itwillbedeterminedby
threefactors:

perband/regulation
perchannelbandwidth
antennagain

maxRegTxPowerdenotethemaximumregulatoryTxPowerfortheequipment,alsohaving
regardtheabovethreepoints.
Then,thefollowingrelationshipmustbesatisfied:
maxAvailableTxPower min(maxRegEIRP
AntennaGain + CableLoss maxRegTxPower)

...(*)

TheTxPower(perradio)indicatesthepowerofeachradioinsidetheODUandisusedforLink
BudgetCalculations.TheTxPower(System)showsthetotaltransmissionpoweroftheODU
andisusedtocalculatetheEIRPaccordingtoregulations.

Notes

ToseetherelationshipbetweenTxPower(radio)andTxPower(sys
tem),notethat dBm = 10 log 10milliWatt sothatifyoudouble
thepowerinmilliWatts(fortworadios)thendBmwillincreaseby
10 log 102 3 .

TheMaxEIRPlevelwillbeautomaticallysetaccordingtothe
selectedbandandregulation.
TheEIRPlevelisthesumoftheSystemTxPowerandtheAntenna
GainminustheCableLoss.
TheMaxEIRPlevelwillbeautomaticallysetaccordingtothe
selectedbandandregulation.
TheEIRPlevelisthesumoftheSystemTxPowerandtheAntenna
GainminustheCableLoss.

RADWIN5000HPMPUserManual

Release3.5.50

E4

ConsiderationsforChangingAntennaParameters

Theinequality(*)aboveisalwayssatisfiedbythesysteminaccordancewiththerelevant
regulation.
Thepreciserelationshipbetweentheitemsininequality(*)isasfollows:

RequiredTxPower(perradio)willbeadjusteddowntothelesserofthevalueentered
andmaxAvailableTxPower
TxPower(system)ismaxAvailableTxPower+3(for2radios)
MaxEIRPismaxRegEIRP.
EIRPismaxAvailableTxPower+AntennaGainCableLoss

RADWIN5000HPMPUserManual

Release3.5.50

E5

AppendixF:

RegionalNotice:French
Canadian
Procduresdescurit
Gnralits
Avantdemanipulerdumatrielconnectdesligneslectriquesoudetlcommunications,
ilestconseilldesedfairedebijouxoudetoutautreobjetmtalliquequipourraitentreren
contactavecleslmentssoustension.

Miselaterre
TouslesproduitsRADWINdoiventtremislaterrependantl'usagecourant.Lamisela
terreestassureenreliantlafiched'alimentationuneprisedecourantavecuneprotection
deterre.Enoutre:

Lacossedemassesurl'IDUCdoittreconstammentconnectelaprotectionde
terre,paruncbledediamtrede18AWGouplus.Lematrielmontsurrackdoittre
installseulementsurdesracksouarmoiresrelislaterre
UneODUdoitmiselaterreparuncbledediamtrede10AWGouplus
Ilnedoitpasyavoirdefusiblesoud'interrupteurssurlaconnectionlaterre

Deplus:

Ilfauttoujoursconnecterlaterreenpremieretladconnecterendernier
Ilnefautjamaisconnecterlescblesdetlcommunicationdumatrielnonlaterre
Ilfauts'assurerquetouslesautrescblessontdconnectsavantdedconnecterla
terre

RADWIN5000HPMPUserManual

Release3.5.50

F1

Protectioncontrelafoudre

Protectioncontrelafoudre
L'utilisationdedispositifsdeprotectioncontrelafoudredpenddesexigences
rglementairesetdel'utilisateurfinal.TouteslesunitsextrieuresRADWINsontconues
avecdescircuitsdelimitationdesurtensionafindeminimiserlesrisquesdedommagesdus
lafoudre.RADWINconseillel'utilisationd'undispositifdeparafoudresupplmentaireafinde
protgerlematrieldecoupsdefoudreproches.
Matrielsupplmentairerequis
L'quipementrequispourl'installationdumatrielestlesuivant:

PincesertirRJ45(siuncbleprassemblODU/IDUn'estpasutilis)
Perceuse(pourlemontagesurmurseulement)
CblesdeterreIDUetODU
Clef13mm()
CbleODUIDUsinoncommand(typeextrieur,CAT5e,4pairestorsades,24AWG)
Colliersdeserrage
OrdinateurportableavecWindows2000ouWindowsXP.

PrcautionsdescuritpendantlemontagedeODU
Avantdeconnecteruncblel'ODU,laborneprotectricedemasse(visse)del'ODUdoittre
connecteunconducteurexterneprotecteurouunpylnerelilaterre.Ilnedoitpasy
avoirdefusiblesoud'interrupteurssurlaconnectionlaterre.
Seulementunpersonnelqualifiutilisantl'quipementdescuritappropridoitpouvoir
montersurlepylned'antenne.Demme,l'installationouledmontagedeODUoude
pylnesdoittreeffectueseulementpardesprofessionnelsayantsuiviuneformation.

Pourmonterl'ODU:
1.Vrifierquelessupportsdefixationdel'ODUsontcorrectementmislaterre.
2.Monterl'unitODUsurlepylneousurlemur;serfrerlaInstallationsurpylne
etmuraudessous.
3.Connecterlacbledeterreaupointdechssissurl'ODU.
4.RelierlecbleODUIDUauconnecteurODURJ45.
5.Visserlespressestoupedecblespourassurerlescellementhermtiquedesunits
ODU.
6.AttacherlecbleaupylneouauxsupportsenutilisantdescolliersclasssUV.
7.Rpterlaprocduresurlesitedistant.

Nepasseplacerenfaced'uneODUsoustension.

Prudence

RADWIN5000HPMPUserManual

Release3.5.50

F2

ConnecterlaterreIDUC

ConnecterlaterreIDUC
Connecteruncbledeterrede18AWGlabornedemassedel'appareil.L'appareildoittre
constammentconnectlaterre.

Prudence

Lesappareilssontprvuspourtreinstallsparunpersonneldeser
vice.
Lesappareilsdoiventtreconnectsuneprisedecourantavecune
protectiondeterre.
LecourantCCduIDUCdoittrefourniparl'intermdiaired'undis
joncteurbipolaireetlediamtreducbledoittrede14mmavecun
conduitde16mm.

Installationsurpylneetmur
L'ODUoul'OPoEpeuventtremontssurunpylneouunmur.

ContenudukitdemontageODU
LekitdemontageODUcomprendlespicessuivantes:

unegrandeclame(voirFigure F1)
unepetiteclame(voirFigure F2)
unbras(voirFigure F3)
quatrevisseshextteM8x40
deuxvisseshextteM8x70
quatrerondellesplatesM8
troisrondelleslastiquesM8
deuxcrousM8.

FigureF1:grandeclame

RADWIN5000HPMPUserManual

FigureF2:petiteclame

Release3.5.50

FigureF3:bras

F3

Montagesurunpylne

Montagesurunpylne

FigureF4:Montagesurunpylne

RADWIN5000HPMPUserManual

Release3.5.50

F4

Montagesurunmur

Montagesurunmur

FigureF5:Montagesurunmur

RADWIN5000HPMPUserManual

Release3.5.50

F5

Montaged'uneantenneexterne

Montaged'uneantenneexterne
L'antenneexterneoptionnellepeuttremontesurunpylne.

Contenudukitdemontaged'uneantenneexterne
Lekitdemontaged'uneantenneexternecomprendlespicessuivantes

Douzerondellesplates
Huitrondelleslastiques
Huitcroushex
Quatreboulons
UnsupportenU
Unsupportpivotement
Deuxcourroiesdefixationenmtal
Pourinstalleruneantenneexternesurunpylne:
1.AttacherlesupportenUl'arriredel'antenneenutilisantquatrerondellesplates,
quatrerondelleslastiquesetquatrecroushex.
2.AttacherlesupportpivotementausupportenUenutilisanthuitrondellesplates,
quatrerondelleslastiques,quatrecroushexetquatreboulons.
3.Passerlesdeuxcourroiesdefixationparlesfentesverticalesdanslesupport
pivotement.
4.Attacherl'antenneaupylneenutilisantlesdeuxcourroiesdefixation.

Ajusterl'inclinaisonncessaireenutilisantl'chelleangulaireetserrertouslesboulonset
crouslapositionrequise.

RADWIN5000HPMPUserManual

Release3.5.50

F6

Index

Index

Numerics

3.Xbands,licensed618

A
accessingtheAP
withawebbrowser1118
Accessories410
additionalVAPs,preparing1125
AES256,configuring854
airinterface83,94
alarms
active1217
antenna
considerationsforchangingparameters
E4
dualattheHBSandanHSUE1
issuesE1
settingparametersE1
singleanddualE1
singleatbothsitesE2
singleatonesite,dualattheotherE2
Txand84
Assuredthroughput13,635
availability
LinkBudget232

B
BaseStationPanel525
BaseStationRadios42
BaseStation,Installing416

C
Cablesandconnectors414
CapacityUpgrade221
Bulk(Sector)HSU224
IndividualHSU223
Persistency224

RADWIN5000HPMPUserManual

CommunityStringsC2
ConfigurationMenuButtons81,831,93
configuring
FalseRadarMitigation192
GSU163
connectingtoeachVAPasaUser1127
CustomerService1218

D
dateandtime,setting823
DCPoEB3
DCPowerTerminalsB3
DeviceRegistrationFCC5.4GHz201
DFS
about191
FalseRadarMitigation191
registeringthedevice201
TDWRTable205
DiagnosticAids,other1218
DisplayViewPersistence520

E
Ethernet,serviceconfiguration825
events541
recent128
WebInterface2514
ExternalAntennas49

F
FalseRadarMitigation97
configuring192
described191
DFS191
facilities191
FCC/ICConsiderations193

Release3.5.50

Index1

FCC5.4GHzDeviceRegistration201
FCCUCBP,configurationanduse71

G
GPS
forVMU,checking1127
forVMU,WI2519
forVMU,WIMapView2520
Grounding414
GSU
configuring163
described161
functionality162
installation163
kitcontents162
Manager,mainwindow163
preparingforuse163
using161

H
HBS
configuring81
deactivating635
ManagerMainWindow524
managingovertheairfromanHSU187
Preparing113
runningSpectrumViewfrom246
savingsettingsastemplate637
settingupforQoS212
template,creatingnomadicentriesfora
sector637
throughputmode83
HMU
batterymode1112
updatingservices1113
HSS
andlinkconfiguration153
andRFP134
andsectorconfiguration145
cablingsequence144
connectinganHSSunit141
described131,141,151
errornotification145
hardwareinstallation134,141
RadioFramePattern(RFP)with134
toODUunitconnectionpinout134, 14
5
totalcablelength145

RADWIN5000HPMPUserManual

unitwithfivecollocatedODUs145
usingasingleunit143
usingmorethanoneHSSUnit143
HSU
AC44,432,839,A7
configuring91
ConfiguringafixedHSUFromtheHBS6
20
configuringfromHBS831
ConnectionTable830
deregistering637
diagnostics1212
directconfiguration91
downgradingsoftware175
EventsLog538
LinkPerformance538
LinkStatus538
lost637
MainButtonMenu537
Nomadic,configuringfromHBS626
registering
fixed627
nomadic632
Registeringmobile116
RegulatoryConsiderationsfor416
Replacing844
runningSpectrumViewfrom248
settingupforQoS213
Suspending846
updatingservices846,1113
HubSiteSynchronizationseeHSS

I
IDUH
ABaseStationAlternativetoPoEDevices
427
IDUHaggregationunit47
IncorrectIPAddress511
IncorrectPassword512
Installing
BaseStation416
SubscriberUnits429
ToolsandMaterials413,438
unpackingandchecking42
InternalESDProtectioncircuits415
InvalidRead/WriteCommunityString512
IPv6
configuring86
displaymode540

Release3.5.50

Index2

loggingonwith58,610

MinimumSystemRequirements51
Mobility
creatingasectorfromHBStemplate11
15,1117
Saving the HBS Settings for Reuse as a
Template1115

K
KMZfile,generatingforVMUs540

LANPortB3
LBC
antenna,height233
calculations232
EIRP232
ExpectedRSSandFadeMargin232
FresnelZone233
internaldata231
MinandMaxRange232
Overview231,231
running235
service232
userinput231
lightning,protectionagainst415
link
configurationandHSS153
LinkBudgetCalculator,seeLBC
LinkBudget,availability232
LinkCompatibility124
listview517
loggingon
totheWebInterface257
LoggingontoaHSU535
LogonErrorsandCautions511

Nomadic828,841

O
ODU
HBSandHSUA1
toHSSunitconnectionpinout134,145
toPoEcable(HBSandHSU)B1
OnlineHelp1218
OpenSourceCode,useof1119
overexposuretoRFEnergy,preventing414

P
Peakthroughput13
PerformanceMonitoring129
PoE
DCB3
toODUcable(HBSandHSU)B1
PowerOverEthernetDevicesseePoE
preconfiguration1121
confirming1127
starting1120
Preferences,setting539

ManagerTraps1216
mapview515
using520
MaximumInformationRate(MIR)631,840
MIB
controlmethodC2
InterfaceAPIC2
managertrapsC79
parametersC3
ReferenceC1,C1,C1,C72
structure,privateC2,C6
supportedvariablesfromRFC1213C4
terminologyC1
trapparametersC72
trapsC72

RADWIN5000HPMPUserManual

QoS
ConfigurableTimetoLive(TTL)214
overview211
prerequisites211,221
settingup211
settingupanHSUfor213
settinguptheHBSfor212
QualityofService,seeQoS

R
radioparameters1121
RF
ExposureD1
Planning34

Release3.5.50

Index3

RFP
andHSS134
GeneralRadioFramePattern135
RSSExtendedView543,631,92

zoominginandout249
SU2AC839,A7,B3
SubscriberUnits,Installing429
SubscriberUnits,seeHSU43
SwitchingBetweenViews520

S
SBM635,635,101
Assuredthroughput102
defined101
Peakthroughput102
sector
band
changing847
configurationandHSS145
managing81
siteplanning31
StatusPanel525
Security819,837,97
SettingManagerPreferences539
sitepreparation31
PhysicalSurvey33
PreliminarySurvey32
RFSurvey34
sitesurvey31
SmartBandwidthManagement
seeSBM101
SNMPv3
defaultuser,password510
logon815
multiusersupportunder811
predefinedusers812
settingtrapdestinations88
trapauthenticationinEventsPreferences
541
usr,passwordinlogon58
SoftwareUpgrade171
available125
described171
recommended126
required126
upgradinganinstalledsector172
SpectrumView241
described241
displayfunctionbuttons245
mainwindow,HBS242
runningfromHBS246
runningfromHSU248
twowaystorun242
wheredataisstored242

RADWIN5000HPMPUserManual

T
tableview513
Telnet
AccesstoHBS856
AccesstoHSU859
configurationwith856
terminology22
ThroughputChecking126
ThroughputModeforHBS83
TPID189
Traps,Manager1216
typographicalconventions11

U
UnsupportedDevice511
userportconnectorsB3

V
view
list517
map515
table513
VLAN
backgroundinformationontheWEB18
1
configuration of tagging for Ethernet
service187
configurationusingtheManager186
functionality181
managementandserviceseparation18
6
portfunctionality183
QinQ(DoubleTagging)182
requirements181
tagging182
terminology181
untagging183

W
WebInterface
advancedconfigurations256

Release3.5.50

Index4

described251,252
events2514
loggingon257
mainwindow2514
management26
operationaleffects256
prerequisites255,255,256
reset2514
technicalbackground256
using251
WiFi
activeicon117
Connectivity1117
enable,disable1110

RADWIN5000HPMPUserManual

Release3.5.50

Index5

Item

Version

Build

Date

UM

3.5.50

NMS

9.5.90.04

9564

29/07/2014

SWUInventory

3.5.50.00

3552.00

28/07/2014

MIB

9.5.90.00

9561

11/08/2014

9390

11/02/2014

LBC
Releasetype

GA

20/09/2014