Вы находитесь на странице: 1из 1

Rev.

Date: 08 Feb, 2012

Quick Reference Installation Guide


Breaker Models

EHB 008 / EHB 01

EHB 02 / EHB 03 / EHB03P

EHB 04 / EHB 04H

EHB 05

8 ~ 10
n/a

8 ~ 10
n/a

10 ~ 12
n/a

15 ~ 17
n/a

EHB 06 / EHB 10

EHB 13

15 ~ 17
n/a

15 ~ 17
n/a

EHB 17

1)

Gas Charging Pressure


Back-head (Piston accumulator) 2)
High pressure accumulator

bar (psi)
bar (psi)

Pressure Adjust Valve Setting 3)


(Number of turns open from full-close)

(120~150)

n/a

(120~150)

n/a

(150~170)

n/a

(220~250)

n/a

(220~250)

n/a

(220~250)

n/a

15 ~ 17
60

(220~250)
(870)

1.5 ~ 2.0

Hydraulic Piping
Line size (min. internal diameter)
mm (in.)
Acceptable back pressure (max.) 4) bar (psi)

9.5
15

Hose Connections of breaker


Oil supply (IN) & return (OUT)
Air (A)

BSP 3/8" O-Ring Boss


n/a

BSP 1/2" O-Ring Boss


n/a

BSP 1/2" O-Ring Boss


n/a

BSP 1/2" O-Ring Boss


BSP 1/2" O-Ring Boss

BSP 3/4" O-Ring Boss


BSP 1/2" O-Ring Boss

BSP 3/4" O-Ring Boss


BSP 1/2" O-Ring Boss

BSP 1" O-Ring Boss


BSP 3/4" O-Ring Boss

bar (psi)

30 (450) + measured
max. operating pressure

30 (450) + measured
max. operating pressure

30 (450) + measured
max. operating pressure

30 (450) + measured
max. operating pressure

40 (600) + measured
max. operating pressure

40 (600) + measured
max. operating pressure

40 (600) + measured
max. operating pressure

-20 ~ +80 (-4 ~ +176)


1000 ~ 12

-20 ~ +80 (-4 ~ +176)


1000 ~ 12

-20 ~ +80 (-4 ~ +176)


1000 ~ 12

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

EHB 20 / EH 23 / EHB 23

EHB 25

EH 30 / EHB 30 / EHB 32

EHB 40 / EHB 42

EHB 50

EHB 52

RHB 370

15 ~ 17
60

15 ~ 17
60

15 ~ 17
60

15 ~ 17
60

16 ~ 18
60

Pressure Relief (min.)


Acceptable Hydraulic Oil
Operating temperature 5)
Viscosity

C (oF)
cSt

Breaker Models

(3/8)
(220)

12
15

(1/2)
(220)

12
15

(1/2)
(220)

12
15

(1/2)
(220)

19
15

(3/4)
(220)

19
15

(3/4)
(220)

25
10

(1)
(150)

1)

Gas Charging Pressure


Back-head (Piston accumulator) 2)
High pressure accumulator

bar (psi)
bar (psi)

Pressure Adjust Valve Setting 3)


(Number of turns open from full-close)

(220~250)
(870)

2.0 ~ 2.5

(220~250)
(870)

2.5 ~ 3.0

(220~250)
(870)

2.5 ~ 3.0

(220~250)
(870)

2.5 ~ 3.0

(230~260)
(870)

3.0 ~ 3.5

15 ~ 17
60

(220~250)
(870)

2.5 ~ 3.0

16 ~ 18
60

(230~260)
(870)

2.0 ~ 2.5

Hydraulic Piping
Line size (min. internal diameter)
mm (in.)
Acceptable back pressure (max.) 4) bar (psi)

25
10

Hose Connections of breaker


Oil supply (IN) & return (OUT)
Air (A)

BSP 1" O-Ring Boss


BSP 3/4" O-Ring Boss

BSP 1" O-Ring Boss


BSP 3/4" O-Ring Boss

BSP 1-1/4" O-Ring Boss


BSP 3/4" O-Ring Boss

BSP 1-1/4" O-Ring Boss


BSP 3/4" O-Ring Boss

BSP 1-1/2" O-Ring Boss


BSP 3/4" O-Ring Boss

BSP 1-1/2" O-Ring Boss


BSP 3/4" O-Ring Boss

BSP 1-1/2" O-Ring Boss


BSP 3/4" O-Ring Boss

bar (psi)

40 (600) + measured
max. operating pressure

40 (600) + measured
max. operating pressure

40 (600) + measured
max. operating pressure

40 (600) + measured
max. operating pressure

40 (600) + measured
max. operating pressure

40 (600) + measured
max. operating pressure

40 (600) + measured
max. operating pressure

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

-20 ~ +85 (-4 ~ +185)


1000 ~ 10

Pressure Relief (min.)


Acceptable Hydraulic Oil
Operating temperature 5)
Viscosity

C (oF)
cSt

(1)
(150)

25
10

(1)
(150)

32
10

(1-1/4)
(150)

32
10

(1-1/4)
(150)

32
10

(1-1/4)
(150)

32
10

(1-1/4)
(150)

Notes:
1) The prefill N2 gas pressure measured statically (breaker not operating) without down load on the tool at the stabilized gas temperature of +20oC. When checking at different gas temperature, refer to the operating manuals.
2) Recommended value at the normal operating condition (oil flow, oil temperature and viscosity, etc.)
3) The value which is set at the factory to obtain the nominal operating pressure at the middle value of oil flow and back-head gas pressure.
4) The maximum allowed oil pressure at the breaker's connection point to the return line (measured statically without the breaker)
5) The allowed temperature limits when using the oil of vicosity grade 46

32
10

(1-1/4)
(150)

Вам также может понравиться