Академический Документы
Профессиональный Документы
Культура Документы
13
1. A 4 pole, 50 Hz, 3 phase induction motor runs at a speed of 1470 rpm the
frequency of rotor current is ___________ Hz.
1.
1.
2.
25.
3.
50.
4.
60.
2. In the equivalent circuit of a double cage induction motor, the two rotor cage
can be considered
1.
To be in series-parallel.
2.
3.
To be in parallel.
4.
To be in series.
3. What is the relation between rotor copper loss and full load slip?
1.
2.
s / ( 1 - s ).
( 1 - s ) / s.
4.
1 / ( s - 1 ).
2.
3.
4.
5. A 4 pole 50 Hz 3 phase induction motor has a full load slip of 5 % the full load
speed is
1.
750 rpm.
2.
1425 rpm.
3.
2000 rpm.
4.
2600 rpm.
6. A 3 - , 4 pole 50 Hz is running at 1450 rpm under full load. The full load
current is 22 Amp, and the rotor resistance at standstill is 2 . Calculate the
mechanical power developed?
1.
31299 Watt.
2.
32000 Watt.
3.
32500 Watt.
4.
35000 Watt.
52 Nm .
2.
52.9 Nm.
3.
52.5 Nm.
4.
58 Nm.
B - C - A.
2.
B - C - A or C - A - B.
3.
B - C - A.
4.
A - C - B.
0.6.
2.
0.8.
3.
1.0.
4.
1.2.
10. If rotor power output 3 phase induction motor is 15 kW. Then rotor copper
losses at a slip of 4 % will be
1.
600 Watt.
2.
625 Watt.
3.
650 Watt.
4.
700 Watt.
11. The stator loss of a 3 - induction motor is 2 kW. What will be the rotor
copper loss if the motor is running with a slip of 4 % and power input 90 kW?
1.
3.53 kW.
2.
4.53 kW.
3.
2 kW.
4.
84.48 kW.
developed?
1.
45.89 kW.
2.
57.23 kW.
3.
59 kW.
4.
88 kW.
13. If an external resistance is to be added in the rotor circuit of a slip ring motor
then its maximum torque
1.
2.
3.
4.
2.
67 Nm.
3.
77 Nm.
4.
None of these.
15. If a 3 - slip ring induction motor is fed from the rotor side with stator
winding short circuited, then frequency of the current flowing in the short
circuited stator is
1.
supply frequency.
2.
slip frequency.
3.
4.
zero.
16. A 3 - 400 V star connected induction motor has a star connected rotor with
a stator to rotor turn ratio 6.5. The rotor resistance and standstill reactance per
phase are 0.05 and 0.25 respectively. The value of external resistance,
which are inserted in rotor circuit to obtain the maximum torque will be
1.
0.78 .
3.
0.3 .
4.
0.65 .
11 kW and 10 kVAr.
2.
12 kW and 12 kVAr.
3.
4.
2.
2.5 .
4.
23.06 KW.
2.
25.01 KW.
3.
24.11 kW.
4.
26.21 KW.
20. A induction motor full load torque of 60 Nm when delta connected develops a
starting torque of 120 Nm. For the same supply voltage, if motor is changed to
star connection then starting torque developed will be
1.
40 Nm.
2.
60 Nm.
3.
90 Nm.
010203040506070809101112
13
Your content : -