Вы находитесь на странице: 1из 13

010203040506070809101112

13

1. A 4 pole, 50 Hz, 3 phase induction motor runs at a speed of 1470 rpm the
frequency of rotor current is ___________ Hz.
1.

1.

2.

25.

3.

50.

4.

60.

Frequency of rotor current, f2 = s f = 0.02 50 = 1 Hz.

2. In the equivalent circuit of a double cage induction motor, the two rotor cage
can be considered
1.

To be in series-parallel.

2.

To be in parallel with stator.

3.

To be in parallel.

4.

To be in series.

The equivalent circuit of a double cage induction motor is shown below:

The inner and outer cages are in parallel.

3. What is the relation between rotor copper loss and full load slip?
1.

2.

s / ( 1 - s ).

( 1 - s ) / s.

4.

1 / ( s - 1 ).

4. In no load test of an polyphase induction motor, the measured power by the


wattmeter consists of
1.

Copper loss only.

2.

Core loss and copper loss.

3.

Core loss and windage and friction loss.

4.

Core loss and windage and friction.

5. A 4 pole 50 Hz 3 phase induction motor has a full load slip of 5 % the full load
speed is
1.

750 rpm.

2.

1425 rpm.

3.

2000 rpm.

4.

2600 rpm.

6. A 3 - , 4 pole 50 Hz is running at 1450 rpm under full load. The full load
current is 22 Amp, and the rotor resistance at standstill is 2 . Calculate the
mechanical power developed?
1.

31299 Watt.

2.

32000 Watt.

3.

32500 Watt.

4.

35000 Watt.

7. A 3 - , 4 pole, 50 Hz IM is running at 1440 rpm when energized at rated


voltage and frequency, the rotor induced voltage at standstill is equal to 120
Volt. Calculate the starting torque if per phase rotor resistance is 0.2 and per
phase leakage reactance at standstill is 1 ?
1.

52 Nm .

2.

52.9 Nm.

3.

52.5 Nm.

4.

58 Nm.

8. The direction of rotation of a 3 phase induction motor is clockwise. When it is


supplied with 3 phase sinusoidal voltage having phase sequence A - B - C. For
counter clock wise rotation of the motor the phase sequence of the motor the
phase sequence of the power supply should be
1.

B - C - A.

2.

B - C - A or C - A - B.

3.

B - C - A.

4.

A - C - B.

9. If starting current of 3 induction motor is 5 times the rated current, while


rated slip is 4%, then ratio of starting torque to full load torque is
1.

0.6.

2.

0.8.

3.

1.0.

4.

1.2.

10. If rotor power output 3 phase induction motor is 15 kW. Then rotor copper
losses at a slip of 4 % will be
1.

600 Watt.

2.

625 Watt.

3.

650 Watt.

4.

700 Watt.

11. The stator loss of a 3 - induction motor is 2 kW. What will be the rotor
copper loss if the motor is running with a slip of 4 % and power input 90 kW?
1.

3.53 kW.

2.

4.53 kW.

3.

2 kW.

4.

84.48 kW.

developed?
1.

45.89 kW.

2.

57.23 kW.

3.

59 kW.

4.

88 kW.

13. If an external resistance is to be added in the rotor circuit of a slip ring motor
then its maximum torque
1.

Increases but occurs at the same slip.

2.

Decreases but occurs at the same slip.

3.

Does not change but occurs at a lower slip.

4.

Does not change but occurs at a higher slip.

14. A 3 - , 4 pole 50 Hz induction motor has rated output of 10 kW at 1425


r.p.m. Calculate the full load torque?

2.

67 Nm.

3.

77 Nm.

4.

None of these.

15. If a 3 - slip ring induction motor is fed from the rotor side with stator
winding short circuited, then frequency of the current flowing in the short
circuited stator is
1.

supply frequency.

2.

slip frequency.

3.

frequency corresponding to rotor speed.

4.

zero.

16. A 3 - 400 V star connected induction motor has a star connected rotor with
a stator to rotor turn ratio 6.5. The rotor resistance and standstill reactance per
phase are 0.05 and 0.25 respectively. The value of external resistance,
which are inserted in rotor circuit to obtain the maximum torque will be
1.

0.78 .

3.

0.3 .

4.

0.65 .

17. A three phase, 400 V, 50 Hz supplies power to a 3 - phase balanced motor


load If the line current be 25 A, power factor being 0.85, what is the value of
real and reactive power consumed?
1.

11 kW and 10 kVAr.

2.

12 kW and 12 kVAr.

3.

12.7 kW and 10 kVAr.

4.

14.72 kW and 9.123 kVAr.

18. An induction motor running at a slip of 0.01 is operating from 50 Hz supply, if


rotor inductor is one henry, then reactance of the rotor at given slip would be
_____________ ohms .
1.

2.

2.5 .

4.

can not be found.

19. A 400 V, 50 Hz, 30 Hp, 3 phase induction motor is drawing 50 an current at


0.8 pf lagging. The stator and rotor copper loss is 1050 watt and the core losses
are 1200 W respectively. The air gap power of the motor will be
1.

23.06 KW.

2.

25.01 KW.

3.

24.11 kW.

4.

26.21 KW.

20. A induction motor full load torque of 60 Nm when delta connected develops a
starting torque of 120 Nm. For the same supply voltage, if motor is changed to
star connection then starting torque developed will be
1.

40 Nm.

2.

60 Nm.

3.

90 Nm.

010203040506070809101112
13

Please provide your valuable comments

Name : Enter your name here

Email : Enter your email here

Location : Enter your location here

Your content : -

Enter the above code here

2011-2016 electrical4u.The content is copyrighted to electrical4u and may


not be reproduced on other websites.

Вам также может понравиться