Corrective Maintenance

6-7

6.1.1 Alarm Management


The alarm severity of each failure is indicated by the following alarm level and alarm
class. Alarm classes can be modified. Modification is done by Alarm Severity
Setting.
6.1.1.1

Alarm Class
Critical (CR) :
The Critical severity level indicates that a service affecting condition has occurred
and an immediate corrective action is required. Such a severity can be reported, for
example, when a managed object becomes totally out of service and its capability
must be restored.
Major (MJ):
The Major severity level indicates that a service affecting condition has developed
and an urgent corrective action is required. Such a severity can be reported, for
example, when there is a severe degradation in the capability of the managed object
and its full capability must be restored.
Minor (MN):
The Minor severity level indicates the existence of a non-service affecting fault
condition and that corrective action should be taken in order to prevent a more
serious (for example, service affecting) fault. Such a severity can be reported, for
example, when the detected alarm condition is not currently degrading the capacity
of the managed object.
Warning (WR):
The Warning severity level indicates the detection of a potential or impending
service affecting fault, before any significant effects have been felt. Action should be
taken to further diagnose (if necessary) and correct the problem in order to prevent it
from becoming a more serious service affecting fault.

Maintenance

NWD-115477-03E

Submission Prohibited
NEC Internal Use Only
6-8

Corrective Maintenance

6.1.2 Alarm and Status Indication Detail


6.1.2.1

ODU Alarms & Status

Indication

Category

Descriptions

Severity

ODU Alarm

Alarm

ODU hardware failure.

MJ

TX Power

Alarm

The TX PWR is lower than 3 dB.

MJ

TX Input

Alarm

The TX IF signal become out of range from


-29 dBm 5 dB.

MJ

RX Level

Alarm

The reception level becomes lower than -72 dBm ~


-94 dBm level. (It depends on the modulation system
and bit rates).

MJ

ODU CPU / Cable Open

Alarm

CPU of ODU is faulty or IF CABLE between IDU and


ODU is broken or is not connected.

MJ

Mute Status

Status

Indicates the control status of the ODU TX power


output. When the TX power is set to Mute, Status is
issued.

LO REF

Alarm

Loss of Ref LO signal of ODU.

MN

ODU TYPE MISMATCH

Alarm

Indicate connected ODU type is not supported at


iPASOLINK system, or ODU type cannot use in
provisioned modulation setting.

MJ

ODU Power Supply

Alarm

ALM in a case of Power supply interruption to ODU.

MJ

NWD-115477-03E

Maintenance

Submission Prohibited
NEC Internal Use Only
Corrective Maintenance

6.1.2.2

6-9

MODEM-A Alarms & Status

Indication

Category

Descriptions

Severity

Unequipped

Alarm

Reserved and installed optional card is removed from optional


slot.

MJ

Type Mismatch

Alarm

The equipped type of interface is different from configured


type.

MJ

Communication

Alarm

Communication failure of equipment internal control


communication.

MJ

Module

Alarm

Equipment fault

MJ

Tx Bus Error

Alarm

Data communication BUS failure condition in TX direction from


MODEM-A Card.

MJ

Rx Bus Error

Alarm

Data communication BUS failure condition in RX direction


from MODEM-A Card.

MJ

RX SW Status

Status

Radio interface RX SW usage state in Redundant


configuration

TX SW Status

Status

Radio interface TX SW usage state in Redundant


configuration

LOF

Alarm

Loss of Frame at radio side.

MJ

Frame ID

Alarm

Frame ID (route differentiation ID)

MJ

High BER

Alarm

Radio signal degradation (High BER threshold detection).


(Threshold :1E-3/1E-4/1E-5)

MJ

Low BER

Alarm

Radio signal degradation (Low BER threshold detection).


(Threshold. :1E-6/1E-7/1E-8/1E-9)

MN

Early Warning

Alarm

Radio signal degradation (Early Warning threshold detection).


(Threshold :1E-9)

MN

MOD

Alarm

Indicates the operating status of the MOD. When any failure


occurs in the modulator section, Alarm is issued.

MJ

IF Cable Short

Alarm

IF cable between IDU - ODU is in short condition.

MJ

XIF

Alarm

XIF cable connection error between XPIC master and slave


MODEM cards

MJ

InPhase

Status

In - Phase indicates the received signal DADE status between


No.1 and No.2 MODEM interfaces are in Phase condition. In
this condition, hitless switch over is available.

L2SYNC Loss

Alarm

Loss of frame synchronization of GFP frames on MODEM


port.

MJ

RDI

Alarm

RDI indication reception alarm on MODEM port

WR

UAE

Alarm

UAE alarm. Indicates the occurrence of an Unavailable state.

WR

XPIC Mode
Mismatch

Alarm

XPIC configuration of two MODEMs is not configured as


Master-Slave.

MJ

TDM / AMR Range

Alarm

Mismatch condition when the mapping number of E1 channels


are different between TX and RX modem ports or mismatch
condition of selected RX AMR modulation range and TX AMR
modulation range.

MJ

FAIL

Mismatch

Maintenance

NWD-115477-03E

Submission Prohibited
NEC Internal Use Only
6-10

Corrective Maintenance

Indication

Category

Descriptions

Severity

ATPC Power Mode

Status

ATPC control signal fault (90sec) as well as MAX Power


continuation 90sec.

TX SW Reverse
Request

Status

TXSW request signal receiving condition from the opposite


station:

TX SW Lock-in
Status

Status

TXSW Lockin state

Unlocked

Alarm

Wireless synchronization status of the local side.

MJ

MODEM Power
Supply Alarm

Alarm

Indicate power off condition of power switch which is in front of


MODEM-A card.

MJ

6.1.2.3

STM1-A Option Card Alarms & Status

Indication

Category

Descriptions

Severity

Unequipped

Alarm

Reserved and installed optional card is removed from


optional slot.

MJ

Type Mismatch

Alarm

The equipped type of interface is different from


configured type.

MJ

Communication FAIL

Alarm

Communication failure of equipment internal control


communication.

MJ

Module

Alarm

Equipment fault

MJ

Tx Bus Error

Alarm

Data communication BUS failure condition in TX


direction from STM1-A Card.

MJ

Rx Bus Error

Alarm

Data communication BUS failure condition in RX


direction from STM1-A Card.

MJ

APS Online Status

Status

APS line protection online status indication

SFP Type Mismatch

Alarm

Mismatch between SFP on LCT and installed SFP.

MJ

SFP Removed

Alarm

A SFP is removed.

MJ

STM-1 LOS

Alarm

LOS detection on STM-1 Optical port.

MJ

TF

Alarm

Transmit Failure detection on STM-1 optical port.

MJ

RS LOF

Alarm

SDH Frame synchronization lost in RS (Regenerator


Section) on STM-1 port.

MJ

RS TIM

Alarm

Trace Identifier Mismatch detected in RS


(Regenerator Section) on STM-1 port.

MJ

RS EXC

Alarm

B1 Byte error occurrence in RS (Regenerator


Section) on STM-1 port.

MJ

RS DEG

Alarm

B1 byte error in RS (Regenerator Section) (RS Degraded) on STM-1 port.

MN

MS AIS

Alarm

AIS detection in MS (Multiplex Section) on STM-1


port.

MJ

MS RDI

Alarm

Remote Defect Indication reception in MS (Multiplex


Section) on STM-1 port.

MJ

NWD-115477-03E

Maintenance

Submission Prohibited
NEC Internal Use Only
Corrective Maintenance

6-11

Indication

Category

Descriptions

Severity

AU AIS

Alarm

AIS detection in AU (Administrative Unit) on STM-1

MJ

AU LOP

Alarm

Loss of AU pointer happens on STM-1 port.

MJ

HP UNEQ

Alarm

HOP (Higher Order Path) Unequipped occurrence on


STM-1 port.

MJ

HP TIM

Alarm

HOP (Higher Order Path) Trace Identifier mismatch


occurrence on STM-1 port.

MJ

HP PLM

Alarm

Payload Label Mismatch occurrence in HOP (Higher


Order Path) on STM-1 port.

MJ

HP RDI

Alarm

RDI (Remote Defect Indication) reception in HOP


(Higher Order Path) on STM-1 port.

MJ

LOM

Alarm

Loss of Multi-Frame on STM-1 port.

MJ

TU AIS

Alarm

In TU (Tributary Unit), AIS detection on STM-1 port.

MJ

TU LOP

Alarm

Loss of TU Pointer on STM-1 port.

MJ

LP UNEQ.

Alarm

LP (Lower Order Path) Unequipped occurrence on


STM-1 port.

MJ

LP RDI

Alarm

Remote Defect Indicate reception by an LP (Lower


Order Path) on STM-1 port.

MJ

LP PLM

Alarm

Payload Label Mismatch Failure occurrence by an LP


(Lower Order Path) on STM-1 port.

MJ

ALS

Status

Indication of automatic laser shutdown condition at


STM-1 optical port.

RS UAS Status

Status

UAS status indication on STM port (Repeater


Section)

STM-1 AIS Generated

Status

AIS generation condition on STM port.

PJE

Status

Pointer justification Event indication at STM port.

port.

6.1.2.4

16E1-A Option Card Alarms & Status

Indication

Category

Descriptions

Severity

Unequipped

Alarm

Reserved and installed optional card is removed from


optional slot.

MJ

Type Mismatch

Alarm

The equipped type of interface is different from


configured type.

MJ

Communication FAIL

Alarm

Communication failure of equipment internal control


communication.

MJ

Module

Alarm

Equipment fault

MJ

Tx Bus Error

Alarm

Data communication BUS failure condition in TX


direction from 16E1-A Card.

MJ

Rx Bus Error

Alarm

Data communication BUS failure condition in RX


direction from 16E1-ACard.

MJ

Maintenance

NWD-115477-03E

Submission Prohibited
NEC Internal Use Only
6-12

Corrective Maintenance

Indication

Category

Descriptions

Severity

E1 LOS

Alarm

No signal input on E1 port

MJ

E1 AIS

Alarm /

PDH AIS

MJ / -

Status

ALARM/Status category can change according to "


AIS Received Condition Setting

Usage Error

Alarm

Unused E1 CH input signal detection.

MN

E1 AIS Generated

Status

AIS generation condition on every E1 Channels.

6.1.2.5

AUX-A Option Card Alarms & Status

Indication

Category

Descriptions

Severity

Unequipped

Alarm

Reserved and installed optional card is removed


from optional slot.

MJ

Type Mismatch

Alarm

The equipped type of interface is different from


configured type.

MJ

Communication FAIL

Alarm

Communication failure of equipment internal control


communication.

MJ

Module

Alarm

Equipment fault

MJ

Tx Bus Error

Alarm

Data communication BUS failure condition in TX


direction from AUX-A Card.

MJ

Rx Bus Error

Alarm

Data communication BUS failure condition in RX


direction from AUX-A Card.

MJ

Item Name (Input-x)

Status/
Alarm

HKA Status Indication {Alarm, Normal} for every


HKA input.

- or

Item Name (Cluster-x)


Item Name (Output-x)

Status

HKC Status {Alarm, Normal} for every HKC output.

NWD-115477-03E

Severity
selectable

Maintenance

Submission Prohibited
NEC Internal Use Only
Corrective Maintenance

6.1.2.6

6-13

GbE-A Option Card Alarms & Status

Indication

Category

Descriptions

Severity

Unequipped

Alarm

Reserved and installed optional card is removed from


optional slot.

MJ

Type Mismatch

Alarm

The equipped type of interface is different from


configured type.

MJ

Communication FAIL

Alarm

Communication failure of equipment internal control


communication.

MJ

Module

Alarm

Equipment fault

MJ

Tx Bus Error

Alarm

Data communication BUS failure condition in TX


direction from GbE-A Card.

MJ

Rx Bus Error

Alarm

Data communication BUS failure condition in RX


direction from GbE-A Card.

MJ

SFP Type Mismatch

Alarm

Mismatch between SFP on LCT and installed SFP.

MJ

SFP Removed

Alarm

A SFP is removed.

MJ

ETH LOS

Alarm

LOS detection at Optical ETH port.

MJ

ETH TF

Alarm

Transmit Fail detection at Optical ETH port.

MJ

LAN LINK

Alarm

LINK of the LAN Port is disconnected.

MJ

Speed & Duplex

Status

LAN Port setting (Speed&Duplex)

6.1.2.7

MSE-A Option Card Alarms & Status

Indication

Category

Descriptions

Severity

Unequipped

Alarm

Reserved and installed optional card is removed from

MJ

Type Mismatch

Alarm

The equipped type of interface is different from

Communication FAIL

Alarm

Communication failure of equipment internal control

optional slot.
MJ

configured type.
MJ

communication.
Module

Alarm

Equipment fault

MJ

Tx Bus Error

Alarm

Data communication BUS failure condition in TX

MJ

direction from MSE-A Card.


Rx Bus Error

Alarm

Data communication BUS failure condition in RX

MJ

direction from MSE-A Card.


TDM Buffer Underrun

Alarm

When packets at Ether side of the PWE path are not

MJ

received or a problem occurs with received packets.


Adaptive CLK Status

Status

Outputs when the adaptive clock state has changed.

(Acquired, Acquiring, Holdover)

Maintenance

NWD-115477-03E

Submission Prohibited
NEC Internal Use Only
6-14

Corrective Maintenance

6.1.2.8

MC-A4 Alarms & Status

Indication

Category

Descriptions

Severity

Module

Alarm

Equipment fault

MJ

Bus Error

Alarm

Data communication BUS failure condition.

MJ

Unequipped (PS)

Alarm

Installed Power Supply Card is removed from PS


slot.

MJ

Power Supply(PS)

Alarm

Alarm in case of power failure.

MJ

FAN FAIL

Alarm

FAN failure

MJ

Unequipped (FAN)

Alarm

Installed FAN Unit is removed from FAN slot.

MJ

EXT CLK Unequipped

Alarm

Installed CLK2M Module is removed from Main Card.

MJ

EXT CLK Type

Alarm

The equipped type of interface is different from


configured type.

MJ

IDU CPU Alarm

Alarm.

IDU CPU Alarm

MN

Memory FAIL

Alarm

Detection of memory failure

MJ

USB FAIL

Alarm

USB memory failure indication

WR

Temperature

Alarm

The temperature is over the threshold

MJ

Maintenance

Status

Maintenance declaration.

CLK FAIL

Alarm

Reference Clock Failed.

MN

CLK Drift

Alarm

Reference Clock source Frequency drift condition

MN

LTI

Alarm

Loss of all incoming timing source

MJ

CLK Status Changed

Status

Reference clock change status

Mismatch

(1) (Locked Ref1)


(2) (Locked Ref2)
(3) (Locked Ref3)
(4) Holdover
(5) Freerun
SSM FAIL

Alarm

Received Sync Status Message value is in unstable


condition.

MN

Squelch

Status

The condition of External CLK Output is in squelch


condition.

EXT CLK LOS

Alarm

Loss of Signal condition of External clock input.

MN

EXT CLK AIS

Alarm

AIS (Alarm Indication Signal) condition of External


Clock input.

MN

EXT CLK LOF

Alarm

Loss of frame condition of External Clock input.

MN

EXT CLK Loop

Alarm

Indication of EXTERNAL clock input is used as


EXTERNAL clock output.

MJ

E1 LOS

Alarm

No signal input on E1 port

MJ

NWD-115477-03E

Maintenance

Submission Prohibited
NEC Internal Use Only
Corrective Maintenance

6-15

Indication

Category

Descriptions

Severity

E1 AIS

Alarm /

PDH AIS

MJ / -

Status

ALARM/Status category can change according to "


AIS Received Condition Setting

PPS FAIL

Alarm

E1 SNCP Path Protection Switch failed

MJ

Usage Error

Alarm

Unused E1 CH input signal detection.

MN

E1 AIS Generated

Status

AIS generation condition on every E1 Channels.

ETH LOS

Alarm

LOS detection at Optical ETH port.

MJ

ETH TF

Alarm

Transmit Fail detection at Optical ETH port.

MJ

SFP Type Mismatch


(ETH)

Alarm

Mismatch between SFP on LCT and installed SFP.

MJ

SFP Removed (ETH)

Alarm

A SFP is removed.

MJ

LAN LINK

Alarm

LINK of the LAN Port is disconnected.

MJ

Speed & Duplex

Status

LAN Port setting (Speed&Duplex)

ETH-OAM LOC

Alarm

ETH OAM LOC ( Loss of connectivity) is detected on


the indicated MEP

MJ

ETH-OAM Mismerge

Alarm

ETH OAM Mismatch detection notice.

MN

ETH-OAM Unexpected
MEP

Alarm

ETH OAM Unexpected MEP and Ether OAM


Unexpected Period detection notice

MN

ETH-OAM RDI

Alarm

ETH OAM RDI reception detection notice

MJ

LLF Message Timeout

Status

Loss of a conditional signaling in which the LLF


control signal should be received continuously from
the opposite radio equipment.

LLF

Status

LLF force a LINKDOWN status. The Ethernet port


under "edge" mode becomes LINKDOWN.

IDU TOTAL ALM

Alarm

IDU TOTAL ALM

The highest
Severity will
be reported

6.1.2.9

Radio Traffic Aggregation Link Alarm

Indication

Category

Descriptions

Severity

Radio Traffic
Aggregation Link

Alarm

All of member ports belong to the radio group are


down.

MJ

6.1.2.10 ETH GRP Alarm


Indication

Category

Descriptions

Severity

LAG Link

Alarm

All of member ports belong to the ETH Link


Aggregation group are down.

MJ

Maintenance

NWD-115477-03E

Submission Prohibited
NEC Internal Use Only
6-16/END

Corrective Maintenance

6.1.2.11 TCN Alarms


Indication

Category

Descriptions

Severity

RF OFS

Alarm

Threshold Crossing Notification

MN

RF BBE

Alarm

Threshold Crossing Notification

MN

RF ES

Alarm

Threshold Crossing Notification

MN

RF SES

Alarm

Threshold Crossing Notification

MN

RF SEP

Alarm

Threshold Crossing Notification

MN

RF UAS

Alarm

Threshold Crossing Notification

MN

RS OFS

Alarm

Threshold Crossing Notification

MN

RS BBE

Alarm

Threshold Crossing Notification

MN

RS ES

Alarm

Threshold Crossing Notification

MN

RS SES

Alarm

Threshold Crossing Notification

MN

RS SEP

Alarm

Threshold Crossing Notification

MN

RS UAS

Alarm

Threshold Crossing Notification

MN

DMR RS OFS

Alarm

Threshold Crossing Notification

MN

DMR RS BBE

Alarm

Threshold Crossing Notification

MN

DMR RS ES

Alarm

Threshold Crossing Notification

MN

DMR RS SES

Alarm

Threshold Crossing Notification

MN

DMR RS SEP

Alarm

Threshold Crossing Notification

MN

DMR RS UAS

Alarm

Threshold Crossing Notification

MN

MS BBE

Alarm

Threshold Crossing Notification

MN

MS ES

Alarm

Threshold Crossing Notification

MN

MS SES

Alarm

Threshold Crossing Notification

MN

MS SEP

Alarm

Threshold Crossing Notification

MN

MS UAS

Alarm

Threshold Crossing Notification

MN

E1 CV

Alarm

Threshold Crossing Notification

MN

RX Level (MIN)

Alarm

Threshold Crossing Notification

MN

RX Drop Events

Alarm

Threshold Crossing Notification

MN

RX Undersize Pkts

Alarm

Threshold Crossing Notification

MN

RX Fragments

Alarm

Threshold Crossing Notification

MN

RX CRC Alignment

Alarm

Threshold Crossing Notification

MN

RX Oversize Pkts

Alarm

Threshold Crossing Notification

MN

TX Collisions

Alarm

Threshold Crossing Notification

MN

Errors

NWD-115477-03E

Maintenance