Project :

PROPOSED HOSTEL COMPEX

Client:
Location

COLLEGE OF MEDICINE CICS LTD. U.I, IB.


1 to 2: A to
1ST FLOOR SLAB

Made by

2-WAY SPANNING INSITU CONCRETE SLABS to BS 8110:1997 (Table 3.14)

Checked

5.33
6.23

h mm 175
Top cover mm 25
Btm cover mm 25
LOADING characteristic
Self weight kN/m 4.20
Extra dead kN/m 2.40
Total Dead, gk kN/m 6.60
Imposed, qk kN/m 3.00
Design load, n kN/m 14.04

MAIN STEEL
s
M kNm/m
d mm
k'
k
Z mm
As req mm/m
As min mm/m
As deflection mm/m

mm
Layer
@ mm
As prov mm/m
= %
S max
Subclause
DEFLECTION
fs
Mod factor

P1

mm

Perm L/d

VALID DESIGN
2
Edge 1

A
Plan

f= 1.40

EDGE CONDITIONS
Edge 1
D
C = Continuous
Edge 2
C
D = Discontinuous
Edge 3
D

f= 1.60

Edge 4

Ly = 6.225 m

D
Edge 3

See Figure 3.8 and clauses 3.5.3.5-6

SHORT
SPAN

LONG
SPAN

EDGE 1
Free

EDGE 2
Continuous

EDGE 3
Free

EDGE 4
Free

0.060
24.0
144.0
0.156
0.046
136.2
452
420
792

0.044
17.3
132.0
0.156
0.040
125.4
354
420
620

0.000
0.0
144.0
0.156
0.000
136.8
0
420
~

0.058
23.1
132.0
0.156
0.053
123.7
478
420
~

0.000
0.0
144.0
0.156
0.000
136.8
0
420
~

0.000
0.0
132.0
0.156
0.000
125.4
0
420
~

12
B1

12
B2

12
T1

12
T2

12
T1

12
T2

125

175

250

225

250

250

905
0.628
444
(a)

646
0.490
408
(a)

452
0.314
444
(a)

503
0.381
408
(a)

452
0.314
444
(a)

452
0.343
408
(a)

137
1.928

150

260

TORSION STEEL

BS8110
Reference
Table 3.14

3.4.4.4
Table 3.25

%
Clause
3.12.11.2.7
Eqn 8
Eqn 7

Actual L/d

36.98

As enhanced 75.2% for deflection control

BOTH EDGES DISCONTINUOUS

10

mm/m
mm/m

452

mm/m
mm/m

0
905

mm

As req
As prov T
Additional As T req
As prov B

MA200

c 1.50
s 1.05

Density kN/m 24
(Normal weight concrete)

38.55

STATUS

fcu N/mm 25
fy N/mm 410

0
Job No

Edge 2

Revision

1999 BCA for RCC

MATERIALS

short span, lx
long span, ly

Page

07-Mar-2016

Edge 4

DIMENSIONS

Date
AAB

Lx = 5.325 m

Originated from RCC94.xls on CD

REINFORCED CONCRETE COUNCIL

Table 3.10

ONE EDGE DISCONTINUOUS

420

420
452
0
646

3.5.3.5

452
0
905

503
0
646

Bottom steel not curtailed in edge strips at free edges

SUPPORT REACTIONS (kN/m char uno)


EDGE 1
v
Dead

kN/m

Imposed
Vs

kN/m
kN/m

(See Figure 3.10)

EDGE 2

EDGE 3

Sum vx = 0.692
Sum vy = 0.750

EDGE 4

A, 1-2

2, -A

, 1-2

1, -A

0.346
12.16

0.450
15.82

0.346
12.16

0.300
10.54

5.53
25.9

7.19
33.6

5.53
25.9

4.79
22.4

equations
19 & 20

OUTPUT/SUMMARY
PROVIDE
MAIN STEEL

SHORT
SPAN

LONG
SPAN

EDGE 1
A, 1-2

EDGE 2
2, -A

EDGE 3
, 1-2

EDGE 4
1, -A

R12 @ 125 B1

R12 @ 175 B2

R12 @ 250 T1

R12 @ 225 T2

R12 @ 250 T1

R12 @ 250 T2

CORNER 2
2A

CORNER 3
2

CORNER 4
1

ADDITIONAL
TORSION STEEL
X direction

0
0
0

Y direction

CHECKS
Lx > Ly

OK

placed in edge strips

BAR
< COVER

SINGLY
REINFORCED

MIN
SPACING

MAX
SPACING

OK

OK

OK

OK

Table 3.15

DEFLECTION

OK

GLOBAL
STATUS
VALID DESIGN

Project :
Location

PROPOSED HOSTEL COMPEX


1ST FLOOR SLAB 1 to 2: A to
2-WAY SPANNING INSITU CONCRETE SLABS to BS 8110:1997 (Table 3.14)
Originated from RCC94.xls on CD

Made by

Job No MA200

Date 7-Mar-16

1999 BCA for RCC

APPROXIMATE WEIGHT of REINFORCEMENT


SUPPORT WIDTHS
(mm)

GRIDLINE

WIDTH

300

300

300

300

TOP STEEL

Type

Dia

Spacing

No

Length

Unit wt

Weight

Across grid A
Across grid 2
Across grid 0

R
R
R

12
12
12

@
@
@

250
225
250

24
23
24

1275
1575
1275

0.888
0.888
0.888

27.2
32.2
27.2

Across grid 1

12

250

21

1275

0.888

23.8

Along grid A
Along grid 2
Along grid 0
Along grid 1

R
R
R
R

12
12
12
12

@
@
@
@

250
250
250
250

4
6
4
4

4650
4250
4650
4250

0.888
0.888
0.888
0.888

16.5
22.6
16.5
15.1

Torsion bars

10

0.617

0.0

BOTTOM STEEL
Short span - middle
edges
Long span - middle
edges

R
R
R
R

12
12
12
12

38
10
23
6

4750
5550
5475
6350

0.888
0.888
0.888
0.888

160.3
49.3
111.8
33.8

SUMMARY
Reinforcement density (kg/m)

85.4

@
@
@
@

125
125
175
175

Total reinforcement in bay (kg)

536

Disclaimer
All advice or information from the British Cement Association and/or Reinforced Concrete
Council is intended for those who will evaluate the significance and limitations of its contents
and take responsibility for its use and application. No liability (including that for negligence)
for any loss resulting from such advice or information is accepted by the BCA, RCC or their
subcontractors, suppliers or advisors.
Users should note that all BCA software and
publications are subject to revision from time to time and should therefore ensure that they
are in possession of the latest version.
This spreadsheet should be used in compliance with the accompanying publication
'Spreadsheets for concrete design to BS 8110 and EC2' available from British Cement
Association, Telford Avenue, Crowthorne, Berkshire RG45 6YS.

Status of spreadsheet
Public release version.
Revision history RCC94 Two-way Slabs (Tables)

Date

Version

06-Aug-99 RCC94 v1.0

Action
First public release.
Includes version comments

Reinforced Concrete
ations of its contents
that for negligence)
he BCA, RCC or their
BCA software and
ore ensure that they

panying publication
rom British Cement

Size (kB)