Академический Документы
Профессиональный Документы
Культура Документы
PATENT PENDING
REGISTERED EUROPEAN DESIGN
Modular design
One solution to maintain
Thermal excellence
Optical performance
Energy efficiency
5
Up to
40.000
lumens
SMART
& SIMPLE
PATENT PENDING
REGISTERED EUROPEAN DESIGN
Up to
6480
combinations
TMAX has been designed around the latest in Solid State
Lighting, captured inside a housing that is guaranteed to
last for decades within tunnel environments. Our drive was
to ensure that todays technology will still be applicable and
effective in the future. Under the extremes of actual working
environments the technology within TMAX has been
designed to deliver at up to 60C ambient temperatures.
At Holophane we have aspired to design lighting products
that last for decades, under the harsh conditions experienced
in outdoor environments. Now we have combined scalability
and technology, for one of the most challenging and toughest
conditions in industrial and road lighting applications.
TMAX has been developed to deliver over 110lm/W in as
many as 72 combinations of lumen packages and photometric
distributions. The TMAX concept provides a complete solution
for tunnel applications in a variety of mounting options. With
this wide range of possibilities we can now specifically address
every installation scenario, faced by planners when working
on tunnel lighting projects.
Performance Characteristics
Luminaire Designed to Achieve Ta +25C - Ambient
Configuration N LEDs
Drive
Power
Delivered
LPW at
CCT (K)
Current (mA) Consumption (W) Lumens at 25C (lm) 25C (lm/W)
.L064
8
600
59
c.6000
113
4.000
.L084
10
600
73
c.8000
113
4.000
.L104
13
600
95
c.10000
113
4.000
.L124
15
600
110
c.12000
113
4.000
.L164
20
600
147
c.16000
113
4.000
.L204
24
600
176
c.20000
113
4.000
.L314
40
600
286
c.31000
116
4.000
.L404
48
600
353
c.40000
113
4.000
Thermal Control
Employing the 3 principles of thermal transfer: Conduction via the aluminium housing, Convection through the
ventilations channels and Radiation from all critical components. The luminaire also employs a Venturi effect which allows
air movement over the glass lens which self cleans and provides enhanced lumen maintenance. The driver chamber is
external and housed away from critical LED components. This ensures that the complete system life is maximised.
Optical enclosure
Photometric
distributions
Ventilation filter (GORE) that regulates the pressure changes caused by temperature variations internal
and external of the luminaire. Eliminates condensation and stresses caused by these enviornmental
changes and ensures the IP seal is maintained for the life time of the product.
Fixing
Maintenance
Access to the gear is on the side of the luminaire via 4 Allen metric (5) screws. Cover designed to ensure IP66 seal
is maintained. Connection of luminaire via IP68 connectors. Earthing cable attached to the luminaire body.
Connection between the fixture and gear are achieved by providing an insulated EPR cable free from polyurethane halides which
is equiped with an IP68 connector for quick connection. The cable length is determined by the type of configuration selected.
There are 2 types of cable:
.FL3XX => 3-pin Cable
.FL5XX => 5-pin Cable
Gear Box
The driver is supplied in a bespoke housing. Upon request, we can supply the gear on a separate
gear-tray which excludes the bespoke gear box. This allows onsite installation flexibility.
The gear housing is manufactured from extruded aluminum 6060 T6 anodized. Side covers
are cast aluminum LM6 (EN AC-44100 AlSi12) low copper content <0.1%.
Finished
Anodized aluminum body. Side caps painted RAL-9006 Smooth Gloss (Silver Metallic).
Water Ingress
Protection
Impact Protection
Electrical
Specifications
Weight
10
Designed around the latest LED technology, with a luminous flux range from 6,000 lm to 40,000 lm and a color
temperature of 4,000K. (Neutral White, nw). CRI 70.
Operating current 600mA Ta +40C.
LED Technology
Utilises 8 to 48 LEDS that are attached to the PCB in zero oxygen atmosphere. This process ensures LED robustness
and relaibilty. All LED modules are stress tested prior to integration into the luminaire - this ensures reliability and
eliminates on site failures.
Lifetime
Operating
temperature
IEC 62722-2-1
Luminaire performance Part 2-1: Particular requirements for LED
luminaires
IEC 62717
LED modules for general lighting Performance requirements
European Directive - 2006/95/EC (Low Voltage)
European Directive - 2004/108/EC (EMC)
European Directive - 98/37/EC (Machinery): CE Marked
European Directive on Waste Electrical and Electronic Equipment (WEEE)
Directive 2012/19/EU
UNE-EN ISO 9227:2007
Corrosion tests in artificial atmospheres - Salt spray tests (ISO 9227:2006)
UNE-EN 60529:1992/A2:2013
Degrees of protection provided by enclosures (IP code)
UNE-EN 62384:2007
D.C. or A.C. supplied electronic control gear for LED modules - Performance
requirements (IEC 62348:2006).
UNE-EN 62493:2011
Assessment of lighting equipment related to human exposure to
electromagnetic fields
DIN 40050-9
Road vehicles; degrees of protection (IP-code); protection against foreign
objects; water and contact; electrical equipment
ANSI C136.31-2010
American National Standard for Roadway and Area Lighting Equipment
Luminaire Vibration
11
Modular installation
Modular distribution
TMX.L064.L1L7.GBOX.LRD.FL509.C9.1OLZG
TMX.L204.L1L7.GBOX.LRD.FL309.C9.1OLZG
TMX.L064.L1L7.GBOX.LRD.FL509.C9.1OLZG
TMX.L204.L1L7.GBOX.LRD.FL309.C9.1OLZG
TMX.L064.L1L7.GTRAY.LRD.C9.1OLZG
TMX.L204.L1L7.GBOX.LRD.FL309.C9.1OLZG
12
Modular assembly
Modular
design
Thin profile
extreme adaptability
72mm
13
Thermal
excellence
Long life
Extruded housing with
vented channels.
TMAX utilises natural air movement to convect heat away from the critical
electrical components. It takes advantage of the constant wind flow in the tunnel
to manage the heat and is further improved by the Piston Effect (Bernoulli Effect).
CO
NN
ON
100%
ECTI
Less Temperature
During the design process we have also been able to accommodate the harsh
ambient conditions of the Middle East. TMAX has the option of a 60C ambient.
14
LIFETIME
EFFICIENCY
COST SAVING
RELIABILITY
LONGEVITY
Conduction
LED boards
Radiation
LED boards
The often cited example of the
Bernoulli Effect is the reduction in
pressure which occurs when the fluid
speed increases.
Flow velocity
V1
Flow velocity
V2
A2 < A1
V2 < V1
P2 < P1 !
P2
P1
Piston Effect
Air
Movement
15
Stopping
point
Adaption
point
Product B
Portal
(LED)
TMAX
Stopping
point
Adaption
point
Portal
High-pressure
cleaning
With an IP66 rating T-MAX has been
designed to be hosed down on site
during maintenances.
16
TMAX
Connector between
led module and gear
box- IP68/IP69K
Connection between the luminaire
and gear housing/tray are achieved via
flying leads, fitted with a plug for easy
connection.
Lex
Exit Luminance
Product C
Product A
Portal
Lex
Exit Luminance
TMAX
TMAX
Portal
Hammer screws
Accessible
17
18
Optical Distribution
Long 60 & Wide 45/15
Long 70 & Wide 60/15
Long 70 & Narrow 20
Long 60 & Narrow 20
Long 60 & Narrow 30
Long 70 & Wide Symmetric 40
Long 60 & Narrow Symmetric 20
Long 70 & Narrow Symmetric 30
Asymmetric 50
Lumen
package
ranging from
6000lm to
40000lm
Optical Distributions
Aerial backflow
disposal and
distribution
Asymmetric 50 (.L8L7)
Distribution
and bilateral
symmetric
distribution
Symmetrical
distribution
and unilateral
distribution
Symmetrical
distribution
and overhead
mounting
Elevation
Elevation
Elevation
Floor plan
Floor plan
Elevation
Elevation
Elevation
Floor plan
Floor plan
19
20
Lifespan
Warranty
Security
Saving
Investment
return
Comparison
19%
LED
HPS
HPS /
Technology
LED
36%
LED
HPS
48%
LED
HPS
TMAX
Energy savings
TMAX
Energy savings
TMAX
Energy savings
21
Sealed
for Life
Our total commitment to quality is reflected in that TMAX is sealed for life, a
minimum life of 100,000 h L70B50.
The Gore vent equalizes pressure and prevents the housing seals from leaking.
Time [min]
Without Vents
1 x Vent
Sealing Leakage
22
Long life
components
Mounting options.
Fixing 10L
Fixing 1OL-ZG
24
Fixing 1ZL
Fixing 1ZL-ZG
25
Fixing 1ZL-ZG
Daytime lighting reinforcement. Luminaire and driverbox integrated forming a light spot. Adjustable light
spot. Zenith position focused on the longitudinal axis of
each driveway or lane and lateral position. Continuous
(linear) or point lighting system.
Fixing 20L-ZG
Fixing 2OLP
26
Fixing 2OLS
Fixing 2OLS-ZG
27
Gear Box
Connector
Fixing brackets
28
Gear Tray
Configurator
SERIE
TMX TMAX - Tunnel Luminaire
Code LAMP_TYPE
.L064
LED light engine producing c.6,000 lm with a nominal 4,000K colour temperature
.L084
LED light engine producing c.8,000 lm with a nominal 4,000K colour temperature
.L104
LED light engine producing c.10,000 lm with a nominal 4,000K colour temperature
.L124
LED light engine producing c.12,000 lm with a nominal 4,000K colour temperature
.L164
LED light engine producing c.16,000 lm with a nominal 4,000K colour temperature
.L204
LED light engine producing c.20,000 lm with a nominal 4,000K colour temperature
.L314
LED light engine producing c.31,000 lm with a nominal 4,000K colour temperature
.L404
LED light engine producing c.40,000 lm with a nominal 4,000K colour temperature
Code OPTICAL_DISTRIBUTION
.L1L7
Long 60 & Wide 45/15
.L7L0
Long 70 & Wide 60/15
.L5L6
Long 70 & Narrow 20
.L1L5
Long 60 & Narrow 20
.L1L6
Long 60 & Narrow 30
.L6L6
Long 70 & Wide Symmetric 40
.L1L1
Long 60 & Narrow Symmetric 20
.L7L7
Long 70 & Narrow Symmetric 30
.L8L7
Asymmetric 50
Code
GEAR EQUIPMENT
.GBOX With control gear box
.GTRAY*
Without control gear box (only gear tray)
Code OPTIONAL: HIGH AMBIENT
.D03
Suitable for a maximum ambient temperature of 60C
Code OPTIONAL: FUSE PROTECTION
.CFUS
With fuse included
Code OPTIONAL: CONTROL GEAR
.LRD
LED dimmable DALI protocol
.ANF
LED dimmable 1-10V
Code OPTIONAL: CABLE CONNECTION LENGTH**
.FL309
3 core cable (90 cm) with IP connector
.FL318
3 core cable (180 cm) with IP connector
.FL390
3 core cable (900 cm) with IP connector
.FL509
5 core cable (90 cm) with IP connector
.FL518
5 core cable (180 cm) with IP connector
.FL590 5 core cable (900 cm) with IP connector
Code
COLOUR
.C9
RAL 9006
.RAL**** RAL colour (customer choise)
Code
FIXING METHOD (2)
.1OL*
Kit 1 LED unit: Rotational Bracket for Luminaire
.1OLZG
Kit 1 LED unit: Rotational Bracket for Luminaire & Z
Bracket for Gbox
.1ZL*
Kit 1 LED unit: Z Bracket for Luminaire
.1ZLZG
Kit 1 LED unit: Z Bracket for Luminaire & Z Bracket for
Gbox
.2OLZG
Kit 2 LED unit: Rotational Bracket for Luminaire & Z
Bracket for GBox
.2ZLZG
Kit 2 LED unit: Z Bracket for Luminaire & Z Bracket
for Gbox
.2OPL*
Kit 2 LED unit: Rotational Bracket for Luminaire
Perpendicular
.2OPLZG
Kit 2 LED unit: Rotational Bracket for Luminaire
Perpendicular & Z Bracket for Gbox
. 2OSL*
Kit 2 LED unit: Rotational Bracketfor Luminaire Side
.2OSLZG
Kit 2 LED unit: Rotational Bracket for Luminaire Side
& Z Bracket for Gbox
Code OPTIONAL: OVERVOLTAGE PROTECTION
SYSTEM
.CPROTEC
With overvoltage protection
TMX .L064 .L1L7 .GBOX .D03 .C-FUS .LRD .FL309 .C9
.1OL
.C-PROTEC
* This version will be available under special request after confirm the required gear-tray dimmensions
** See the attached Configuration Matrix to select the option
29
GEARBOX FIXED ON
THE LUMINAIRE
FL3
3 Core cable
02 = 25cm
04 = 40cm
09 = 90cm
18 = 180cm
FL5
5 Core cable
04 = 40cm
09 = 90cm
18 = 180cm
.L164
.L204
.1OLZG
.FL302
.FL302
.FL504
.1ZLZG
.FL302
.FL302
.FL504
.L314
.L404
.2OLZG
.FL304
.FL504
.2ZLZG
.FL304
.FL504
GEARBOX SEPARATED
FROM THE LUMINAIRE
.L064 .L084 .L104
.L164
.L204
.1OLZG
.FL309
.FL318
.FL309
.FL318
.FL509
.FL518
.1ZLZG
.FL309
.FL318
.FL309
.FL318
.FL509
.FL518
.L314
.L404
.2OPLZG
.FL309
.FL318
.FL509
.FL518
.2OSLZG
.FL309
.FL318
.FL509
.FL518
30
Accessories TMAX
Code
Kit 1 LED unit:
TMX.1OLZG
TMX.1ZL (1)
TMX.1ZLZG
TMX.2OLZG
TMX.2ZLZG
TMX.2OPL (1)
TMX.2OPLZG
TMX.2OSL (1)
TMX.2OSLZG
TMX.FL302
TMX.FL304
TMX.FL309
TMX.FL318
TMX.FL390
TMX.FL504
TMX.FL509
TMX.FL518
TMX.FL590
Accessories
Rotational Bracket for Luminaire
Kit 1 LED unit: Rotational Bracket for Luminaire & Z Bracket for Gbox
Kit 1 LED unit: Z Bracket for Luminaire
Kit 1 LED unit: Z Bracket for Luminaire & Z Bracket for Gbox
Kit 2 LED unit: Rotational Bracket for Luminaire & Z Bracket for GBox
Kit 2 LED unit: Z Bracket for Luminaire & Z Bracket for Gbox
Kit 2 LED unit: Rotational Perpendicular Bracket for Luminaire Perpendicular
Kit 2 LED unit: Rotational Perpendicular Bracket for Luminaire & Z Bracket for Gbox
Kit 2 LED unit: Rotational Lateral Bracket for Luminaire
Kit 2 LED unit: Rotational Lateral Bracket for Luminaire Side & Z Bracket for Gbox
3 core cable (25 cm) with IP connector
3 core cable (40 cm) with IP connector
3 core cable (90 cm) with IP connector
3 core cable (180 cm) with IP connector
3 core cable (900 cm) with IP connector
5 core cable (40 cm) with IP connector
5 core cable (90 cm) with IP connector
5 core cable (180 cm) with IP connector
5 core cable (900 cm) with IP connector
31
Dimensions
150mm
.L164/.L204.GTRAY.1ZL
204
660
90
72
633
278
59,5
8,5
60
180
.L314/.L404.GTRAY.20SL
213
450
90
110
161
294
72
570
633
140
100
60
60
11 17
32
.L314/.L404.GTRAY.20PL
213
400
90
200
161
294
72
570
633
140
100
60
60
11 17
.L314/.L404.GBOX.2ZL-ZG
204
570
UP
211
72
633
570
59,5
8,5
60 180
33
.L064/.L084/.L104/.L124.GBOX.1ZL-ZG
150mm
370
204
UP
211
72
390
278
59,5
8,5
60
180
.L164/.L204.GBOX.1OL-ZG
90
213
83
332
UP
72
633
140
100
278
60
60
11 17
34
.L314/.L404.GBOX.2OL-ZG
90
213
83
332
UP
72
633
140
100
570
60
60
11 17
.L064/.L084/.L104.GBOX.1OL-ZG
90
213
83
332
UP
72
390
278
140
100
60
60
11 17
35
.L064/.L084/.L104/.L124.GBOX.1OL
150mm
90
213
83
210
72
390
140
278
100
60
60
11 17
.L164/.L204.1OL
90
213
83
210
72
278
633
140
100
60
60
11 17
36
37
38
39
www.holophane.co.uk