Product

DOP

Models

DOP-AE80
DOP-AE94
DOP-AE10
DOP-A80

Confidential level
ECN No.

Publication No.
FAE-01-H09204-000
Date of Publication
2009/02/04

Published by

Application
Engineering

Published to

TW Sales & PM , DCE , DEU , DPR , DES , DEJ , DEK

Publisher

Eden Chen

 General
 Classified
 Top secret

Purpose:
New version of software 1.05.80 support barcode reader with USB interface , explain how to apply it.

Description:
Applied in manufactory , we could recode the serial number of product by using barcode reader , and
barcode reader could be connected to DOP via USB interface , and we could have multi-HMI connected
with Ethernet module , and we could also organized data by using SCADA software.

QUALITY
RELIABLITY
Page 1/8
EXCELLENT

1. Software Version:

2. Barcode input setting:


a. Select BarCode Entry element

b. The Property table:

Barcode writing address

Barcode length

Input mode

Touch

Active

QUALITY
RELIABLITY
Page 2/8
EXCELLENT

c. What is the different between Touch input and Active input


Touch input : touch the element then you could use the barcode reader to input the barcode.
Active input : enable the interlock address then you could use the barcode reader to input the
barcode
3. Example for Barcode input:
Following was a simple example for Barcode input , including Touch input and Active input , and we
use keyboard to simulate the barcode reader , but if you have a barcode reader , of course you
could use it to input the barcode directly.

a. At Touch input side , must touch the element first and then you could input the barcode
b. At Active input side , must enable the interlock address first and then we could input barcode ,
when the 1st barcode was inputted , HMI will switch to next element automatically and wait for
the next barcode input . when the interlock address was disabled the barcode input will be stop
c. This function also support Two-dimension barcode reader . Cause the length of string is much
longer 1-Ds , so must depend on how many string is going to be read and then adjust the
barcode length.
Barcode length max support to 127
d. For more setting detail , please check the attached file which named barcode.dop

QUALITY
RELIABLITY
Page 3/8
EXCELLENT

4. HMI Ethernet structure


a. Connect multi-HMI with different IP address via Ethernet as figure below

QUALITY
RELIABLITY
Page 4/8
EXCELLENT

b. Setting
(1) Create a new project

Select AE series
Select modbus\TCPIP

(2) OptionsConfigurationCommunicationEthernet

Set IP address
of HMI

QUALITY
RELIABLITY
Page 5/8
EXCELLENT

(3) OptionsConfigurationCommunicationBase Port

Set IP address
of other device

QUALITY
RELIABLITY
Page 6/8
EXCELLENT

(4) If you have more then one device to connect with , press add to create new link

QUALITY
RELIABLITY
Page 7/8
EXCELLENT

(5) So the IP setting of each HMI will be like below figure shows

QUALITY
RELIABLITY
Page 8/8
EXCELLENT