Академический Документы
Профессиональный Документы
Культура Документы
This document was prepared as an account of work sponsored by an agency of the United States
Government. Neither the United States Government nor the University of California nor any of their
employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for
the accuracy, completeness, or usefulness of any information, apparatus, product, or process
disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any
specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise,
does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United
States Government or the University of California. The views and opinions of authors expressed herein
do not necessarily state or reflect those of the United States Government or the University of California,
and shall not be used for advertising or product endorsement purposes.
HIGH ENERGY, HIGH BRIGHTNESS X-RAYS PRODUCED BY COMPTON
BACKSCATTERING AT THE LIVERMORE PLEIADES FACILITY
A.M. Tremaine*, S.G. Anderson, S. Betts, J. Crane, D.J. Gibson, F. V. Hartemann, J.S. Jacob,
LLNL, Livermore, CA., 94551
Reflectivity
Bragg
pulses to the interaction point. K-edge radiography at 115 Diffraction
Detector
keV on Uranium has verified the angle correlated energy
spectrum inherent in Compton scattering and high-energy
tunability of the Livermore source. Current upgrades to T probe - T pump
8
10 a b
7
10
γs
6
1
05 c d
1 40
60 80 10 120 140
0 0 Fig. 4. K-edge radiography through U. 4a. PLEIADES
X-ray Energy tuned to 115 keV k-edge, for on axis x-rays, which are
Fig. 2. Measured x-ray flux
(keV)(photons) vs. x-ray energy abosorbed by k-edge. 4b. PLEIADES tuned away from k-
edge, on axis x-rays begin being transmitted through foil.
In order to produce ultra-short x-rays, the electron 4 c and d are BLOWER simulations.
bunch was compressed in the 1st linac section.
Measurements from a CTR interferometer [8] done on the As expected the x-rays at the k-edge are absorbed by
electron bunch length, and a compressed length of 300 fs the U foil, and those x-rays with energies above or below
was achieved compared to 5 ps uncompressed. The beam the k-edge transmitted. The low angle x-rays (those on
was then overlapped with the FALCON laser, and fs, hard axis) have the highest energy, were tuned to the k-edge
x-rays generated. Fig. 3 shows the x-ray pulses generated and absorbed. The off axis x-rays are lower energy, off the
from the compressed (a) and uncompressed (b) electron k-edge and transmitted. The asymmetry in the k-edge
beam. While compression does transmission is due to the fact that the e-beam was
asymmetric at the IP leading to an asymmetric x-ray
pulse.
Figure 5 shows 30 keV x-rays diffracted from an
Indium Antimonide, (InSb) crystal. The main x-ray beam
is passed through a small aperture to eliminate the off-
axis, low energy x-rays. While this reduces the flux to the
a b
Fig. 3a. X-rays generated from the velocity compressed,
300fs, electron beam vs. (b) uncompressed 5 ps beam.