Вы находитесь на странице: 1из 28

Electrical Catalogue 2014/2015

Electrical Test Equipment from Beha-Amprobe

Beha-Amprobe two of the most famous brands


in the US and Germany have now incorporated
Robin Installation testers within the range
available to customers in the UK and Ireland.
Beha-Amprobe offers wide range of costeffective, innovative test equipment specifically
designed to make the electricians job faster
and easier. This includes the Robin range of
single, dual and multifunction 17th Edition
Installation Testers specifically designed for
testing fixed installations in the UK and Ireland.
Beha-Amprobe products are sold and supported
by a wide range of dealers and are backed up
by a professional support service. The vast
array of Beha-Amprobe products, plus the
incorporation of the Robin electrical range,
means the UK electrician has a one stop shop for
quality, value-priced products which include 17th
Edition Installation Testers, Voltage Detectors,

Multimeters, Clamp Meters, Thermometers


and Two Pole Testers - one of the largest ranges
available to the electrical contractor and engineer.

Single & Dual Function


Installation Testers. . . . . . . . . . . . . . . 3
Portable Appliance Testers . . . . . . . . . 7
Electrical Testers . . . . . . . . . . . . . . . . 9
Clamp-on Meters. . . . . . . . . . . . . . . 12
Digital Multimeters. . . . . . . . . . . . . . . 15
Temperature Measurement . . . . . . . 18
Other Test Equipment. . . . . . . . . . . . 21

Single and Dual Function Installation Testers


Multifunction Installation Testers

The five new Robin-Amprobe single function


testers give total flexibility, choose the tester
you need for the job. Also available in a kit of
three for 17th Edition test capability.
Robin-Amprobe Dual and Multifunction Testers
are specifically designed and built for the UK
electrician. Choose the KTS1625
for your 17th Edition test solution.

KMP7020/KMP7021 KMP7030
Digital RCD Tester

Loop Impedance Tester

KMP7020

KMP7021

Loop testing is a quick, convenient, and highly specific method


of evaluating an electrical circuit for its ability to engage
protective devices (circuit breakers, fuses, RCDs). A loop is
defined by including unsuspected elements, where current has
found parallel paths to ground. A ground loop determines the
effectiveness of protective devices, therefore it is crucial to be
able to measure it, in order to detect and correct problems.

Robin-Amprobe RCD testers are simple to use devices


designed to check for correct operation of RCD devices.
They feature three levels of trip currents with either Fast Trip
or Ramp Test for complete range of testing applications.

Non Trip Loop test

Fast testing

Instant reading

20, 200 & 2000 Loop measurement ranges

A residual-current device (RCD) disconnects a circuit whenever


the electric current is not balanced between the energised
and the neutral conductors. The imbalance indicates that
there is a leakage current outside of the system sometimes
caused by the person accidentally touching the energised part
of the circuit, and sometimes by lack of sufficient insulation
(excessive moisture or worn out, poor quality insulation
materials). RCDs are designed to disconnect quickly to mitigate
the harm caused by such shocks and to avoid current leaks
which may lead to fire and other dangerous situations.

PSC measurement up to 20kA

Displays mains voltage before test

Instant correct wiring status check

Designed to allow testing to BS7671

Three levels of trip currents (x1/2, x1, x5) for complete


range of testing applications
- Fast Trip Function (KMP7020)
- Ramp Test (KMP7021)

3-LED proper connection indicator

Phase switch selection 0 and 180 for


positive and negative semi-cycle testing

Designed to allow testing to BS7671


IEE 17th Edition regulations

Large display

Safety CAT III 300V

IEE 17th Edition regulations


n

Backlight display

Low Battery Indication

CAT III 300V

KMP7010

KMP7036

Robin-Amprobe Ground Resistance Testers are designed


to measure resistance of the grounding systems to verify
that the system has low enough resistance to provide
protection for people, equipment and structures.

The Robin-Amprobe Insulation-Continuity Tester is designed


to diagnose and prevent the breakdown of the insulation in
various parts of the electrical system such as wires, transformers
and motors. The KMP7036 features three testing voltages
covering wide range of commercial and residential applications.

A properly functioning grounding system is a critical safety


feature of an electrical system. It is used to mitigate the risk
when exposed metal parts come in contact with dangerous
voltages in the event an installation fails. The building
structures are protected by grounding systems to divert
energy of lightning strikes straight to ground. Connections to
ground limit the build-up of static electricity when handling
flammable products or when repairing electronic devices.
 easures Earth ground resistance M
3 point (fall of potential) or 2 point tests
n 
Voltage measurement prevents false measurements
n 
Test leads, auxiliary electrodes are
included for a complete instrument
n 
Built-in memory to store 20 measurements
n 
Designed to allow testing to BS7671 IEE 17th
Edition regulations
n 
Safety CAT III 600V
n

Insulation-Continuity Tester

The quality of insulation is critical to assure proper,


uninterrupted and safe functioning of electrical circuits.
 ests insulation of wires, cables,
T
transformers and electrical motors
n Selectable test voltages 250V, 500V and 1000V
n Test button hold to perform the

Dielectric Absorption Ratio Test
n Continuity test @ 200mA short-circuit
n Designed to allow testing to BS7671

IEE 17th Edition regulations
n Built in voltmeter and red light warning

for live circuit indication
n Automatic discharge of test object after

completion of measurement
n Test lead resistance zero facility
n Safety CAT III 600V
n

Single-Function Installation Testers

Ground Resistance Tester

Kits - Single Function Installation Testers


17A
KMP7036 Insulation Tester

17B
Carry case included
with both kits

+
KMP7030 Earth Loop Impedance Tester

+
KMP7036 Insulation Tester

KMP7020 RCD Tester

KMP7030 Earth Loop Impedance Tester

5
KMP7021 RCD Tester

KTS1625

Digital Multifunction Tester


(Insulation / Continuity / Loop / RCD / Voltage

Safety and performance are two most critical requirements


for every electrical system. The quality of insulation, properly
working grounding system and active protection are to
assure safety of people, electrical systems and buildings
against electrocution, fire, and other equipment damage.
Robin-Amprobe KTS1625 tester verifies the safety of electrical
installations in domestic, commercial and industrial applications. It
can ensure that fixed wiring is safe and correctly installed to meet
the requirements of BS7671 IEE 17th edition wiring regulations.

n Continuity Functions
- Continuity resistance @ 200mA
n Insulation Function
- Selectable test voltages 250V, 500V & 1000V
n Line / Loop Impedance Functions
- Prospective earth fault current
- Prospective short-circuit current
- Non Trip Loop test
- Fast testing
n RCD Functions
- Three levels of trip currents (X, X1, X5)
for complete range of testing applications
- Phase switch selection 0 and 180 for
positive and negative semi-cycle testing
- RCD ramp test
- Tests time delayed RCDs (S-type)
- Test pulse sensitive (DC) RCDs
- Auto RCD test
n 
Designed to allow testing to BS7671
IEE 17th Edition regulations
n 
Voltage and frequency measurements
n 
Instant correct wiring status check
n 
Dual measurement result display
n 
Large, backlit display
n 
Low battery indication
n 
Safety CAT III 300V

KMP7100

Dual Function Loop /


RCD Tester

Robin-Amprobe KMP7100 is a dual function installation


tester combining both Earth Loop Impedance tester and
RCD tester in one compact easy to use package. Ideal for
use with the Robin Amprobe 7036 Insulation tester.
n Loop Functions
- Non Trip Loop test
- Fast testing
- 20, 200 & 2000 Loop measurement ranges
- PSC measurement up to 20kA
- Displays mains voltage before test
- Instant correct wiring status check
n RCD Functions
- Three levels of trip currents (X1/2, X1, X5)
for complete range of testing applications
- Phase switch selection 0 and 180 for
positive and negative semi-cycle testing
- Test pulse sensitive (DC) RCDs
- Auto RCD test
- Selectable 25V/50V fault voltage for RCD test
n

n
n

 esigned to allow testing to BS7671


D
IEE 17th Edition regulations
Displays mains voltage before test
 Test lock for automatic start test
when connected to circuit
Dual measurement result display - primary display for
 CD/Loop measurement, secondary
R
display for circuit voltage

Built-in Volt meter

Safety CAT III 300V

Accessories for Robin-Amprobe testers


ERT2

Earth resistance kit

SL17B

Standard test lead set e/leads, probes,


alligator clips and mains lead

TP1625

Test probe with remote test button for KTS1625

SL7030

Standard test lead set for KMP7030

KP1700

Single function tester kit carry bag

SL17E

Fused test lead set w/probes, alligator clips

Portable Appliance Testers

Robin-Amprobe Portable Appliance Test


Built Tough to Test the Safety and Integrity
of Electrical Appliances

GT-400-UK

Portable Appliance Tester

The new Robin-Amprobe GT-400-UK Portable


Appliance Tester, is a light- weight, portable appliance
tester that tests the integrity of electrical devices.
Developed for the commercial electrician or facilities
maintenance persons to carry out a wide variety of
safety measurements of electrical appliances, the
GT-400-UK is extremely easy to use. Measuring
earth ground and insulation resistance, as well as
current, the GT-400-UK will ensure safety,
functionality and compliance of regulatory standards.
n

Intuitive and simple to use with no training required

Easily portable for on the go testing

Fast answers - Instantly measures safety and


integrity of electrical appliances

Measures earth bond resistance

Insulation resistance measurements up to 500V

Substitute Leakage Current measurements

Protective Conductor Current measurements

Rugged with high quality construction for years of service

Tests appliances for safety in accordance


with the IET Code of Practice, EN 61010 Safety Standards

Electrical Testers

The range of Beha-Amprobe Electrical Testers


include Non-contact & Two Pole Testers.

VP-700-E

Voltage Tester with


Rotary Field Indicator
n

Voltage test (12-690V AC/DC)

Two pole phase rotation

VP-710-E

Voltage Tester with


Phase Rotation
Voltage test (12-690V AC/DC)
n Two pole phase rotation indication,
no third hand required
n Single pole test for phase polarity
n Continuity test
n Switchable Load of 140 W with two
push buttons, tripping of 30 mA RCD
n Automation AC/DC voltage
indication, indication of polarity
n IP 64, splash-proof and
dust-tight protection
n Probe tip protection for reducing
the danger of injuries (attached
to lead - permanently available)
n

indication, no third hand required


n

Indication of polarity

Switchable Load of 140 W


with two push buttons,
tripping of 30 mA RCD

IP 64, splash-proof and


dust-tight protection

Probe tip protection for reducing


the danger of injuries (attached
to lead - permanently available)

Additional Features
n No unawared tripping of RCD
n No battery required
n Quick single-hand on 19 mm contact distance outlets,
without removing test probe from instrument
n Built and certified according latest voltage tester
standard EN-61243-3:2010, DIN VDE 0682-401:2011

Additional Features
n Quick single-hand on 19 mm contact distance outlets,
without removing test probe from instrument
n Torch function via white LED
n Built and certified according latest voltage tester
standard EN-61243-3:2010, DIN VDE 0682-401:2011

VP-720-E

Voltage Tester LCD with Phase Rotation


Voltage test via LCD-Display and
LED-Bargraph (12-690V AC/DC)
n Single pole test for phase polarity
n Continuity test
n Two pole phase indication,
no third hand required
n Switchable Load of 140 W
with two push buttons,
tripping of 30 mA RCD
n Automatic AC/DC voltage
indication, indication of polarity
n IP 64, splash-proof and
dust-tight protection
n Probe tip protection for reducing
the danger of injuries (attached
to lead - permanently available)
n

10

Additional Features
n Vibration function
n Test of 30mA RCD by both push buttons,
avoids unintended tripping of RCD
n Torch function via white LED
n Quick single-hand test on 19 mm
contact distance sockets
n Built and certified according to latest voltage tester
standard EN-61243-3:2010, DIN VDE 0682-401:2011

VP-440 RT

Non-contact Voltage
Tester
n

ECB50A-E

Circuit Breaker Finder

Non-contact, optical

detection of AC voltages
n

50-1000V AC

Fast, accurate detection of

fuses and assignment to circuits


n

Set consisting of transmitter and


receiver in robust carrying case

cables, e.g. cable drums


Compact, handy design

that fits in any pocket


n

Locating and tracing


of cables in walls

cable breaks in open-ended


n

Fast and accurate locating of

T
 ransmitter signal displayed
optically and acoustically

Wide range of applications

by the receiver

in trade and industry

T
 ransmitter with integrated
BS1363 UK plug enabling easy
connection to mains socket

Simple switching between fuse


and cable finder function

Continuous sensitivity

2050-D

VOLTfix plus non-contact


voltage tester
Non-contact, optical and acoustic

VP-450-E

Non-contact Voltage
Tester
n

Non-contact, optical and acoustic

location of line breaks in cables lying

50-600V AC

open e.g. cable drums. Reliable, automatic

Fast, accurate detection of

detection of AC voltages. Fast, exact

detection of AC voltages

self-test at start-up of the equipment

cable breaks in openended

by visual standby display. Compact,


handy design, which fits in any pocket.

Voltage Testers

adjustment of receiver

cables, e.g. cable drums


n

Reliable, automatic selftest of activated device with

CAT III 600 V

Optical and acoustic detection

Integrated flashlight

Compact, handy design

Optical standby display.

optical readiness indicator


n

Compact, handy design


that fits in any pocket

Wide range of applications


in trade and industry

Additional Features
n

On/off switch

11

Clamp-on Meters

Beha-Amprobe are renowned around


the world for innovative Clamp Meters.
The selection includes the Swivel Clamp
Meter and the high performance
Navigator Clamp.

12

ACD-14 PLUS

Current clamp with dual


display up to 600 A (AC)

ACDC-400

Clamp Multimeter 400A


Current, voltage and
resistance measurement
n Continuity test with beeper
n Automatic and manual
range selection
n Integrated measurement
memory (data hold, MIN/MAX)
n Relative measurement
n Additional bar graph display
n Jaw opening: 30 mm
n Auto power-off
n

Additional Features
n Dual display
n A measurement range for direct
measurement of ionisation
currents in heating systems

ACD-20SW

Swivel Clamp Meter 400A


Measures current, voltage
and resistance
n Audible continuity test
n Diode test
n Auto and manual ranging
n Measured data storage
(Data Hold)
n Accomodates conductors
up to 30 mm in diameter
n Auto-Power-Off

Additional Features
n AC/DC clamps are also suitable
for automotive applications,
emergency power supplies
and solar technology
n Backlight

ACDC-100

Clamp Multimeter 1000A


Current, voltage and
resistance measurement
n Continuity test with beeper
n Measurement of inrush
current (30 ms)
n Automatic and manual
range selection
n Integrated measurement
memory (data hold)
n Jaw opening: 50 mm
n Auto power-off

Additional Features
180 degree rotating head
for the perfect display
n Advanced VoltTect noncontact voltage detection

Clamp-on Meters

Current, voltage and


resistance measurement
n Continuity test with beeper
n Capacitance and frequency
measurement
n Temperature measurement
n Measurement of inrush current
n Automatic range selection
n Integrated measurement memory
(data hold and MAX hold)
n Jaw opening: 26 mm
n Auto power-off
n

Additional Features
Large, clear display

13

ACD-50NAV

600A AC Navigator Clamp

LH41

Current Clamp Meter AC/DC

Current, voltage and


resistance measurement
n Measurement of active
power (W)
n Measurement of the
power factor cos
n Acoustic continuity test
n Capacity and frequency
measurement
n Harmonics measurement for
current and voltage values
(up to the 25th harmonic)
n THD measurement
n Integrated measurement
memory (Data Hold,
n Measurement of the
MIN/MAX)
inrush current
n Display of the rotary
n Additional bargraph display
field direction
n Peak value measurement
n Automatic measuring
n Low Pass frequency filter
range selection
n Large clear display with
background light
n TRMS measurement (ACD52NAV, ACD-53NAV,
n Clamp opening 37 mm
ACD-54NAV only)
n Auto-Power-Off
n

Additional Features
Real effective value measurement AC+DC (TRMS)
Contactless voltage detection
Measurement point illumination by means of white LED

n
n
n

ACDC-54NAV

1000A AC/DC TRMS


Navigator Clamp
Current, voltage and
resistance measurement
n Acoustic continuity test
n Capacity and frequency measurement
n Temperature measurement
n Measurement of effective power (W)
n Measurement of the
power factor cos
n Harmonic measurement for
current and voltage values
(up to the 25th harmonic)
n Measurement of the inrush current
n Display of the rotary field direction
n Automatic measuring range selection
n Integrated measurement memory
(Data Hold, MIN/MAX)
n Additional bargraph display
n Peak value measurement
n Low Pass frequency filter
n Large clear display with
background light
n Clamp opening 42 mm
n Auto-Power-Off
n

14

Additional Features
n Real effective value measurement AC+DC (TRMS)
n Contactless voltage detection
n Measurement point illumination by means of white LED

Current measurement
from 1 mA AC and DC

Manual range selection

Jaw opening: 19 mm

Automatic zero-point (DC


measurement range)

Integrated 5 s measurement
memory (data hold)

Auto power-off

Additional Features
n

Minimum resolution: 1 mA

Shielded against external


interference

AC50A

Leakage Clamp Meter


n

Leakage current measurement

Voltage and resistance


measurement

Continuity test with beeper

Manual range selection

Integrated measurement
memory (data hold)

MIN/MAX and relative


value measurement

Additional bar graph display

Jaw opening: 30 mm

Auto power-off

Additional Features
n

Minimum resolution: 0.01 mA

Range of applications:
measurement of leakage
or fault currents, current
consumption of devices in
(customer) service sector
without breaking the circuit

Digital Multimeters

Beha-Amprobe offer a wide range of Digital


Multimeters for the UK electrician at
affordable prices.

15

AM-500-EUR

Compact Size DMM

AM-510-EUR
DMM

A
 utoranging feature
automatically sets up
voltage, current, and
resistance ranges for you
n V
 oltage up to 600V AC/DC
n R
 esistance
n A
 udible continuity
n D
 iode test
n D
 ata hold
n A
 uto power off
n L
 ow battery warning
n

600V AC/DC

10A AC/DC

Capacitance and frequency

Temperature measurement

Automatic and manual

measurement

range selection

S afety rated: CAT III 600V

Auto power off

Battery test (1,5V and 9V)

Non-contact voltage detection

Built-in flashlight

Contents

Contents

Model AM-510 EUR


Test leads

Model AM-500 EUR

Test leads

1 x 9V (6F22) battery (installed)

AAA x 2

Users manual

Users manual

AM-520-EUR
DMM

n
n
n

7 50V AC/DC
10A AC/DC
Capacitance and frequency

AM-530-EUR
DMM TRMS

AC 750V/DC 1000V

10A AC/DC

TRMS measurement

Capacitance and frequency

measurement

measurement

Temperature measurement

Temperature measurement

Automatic and manual

Automatic and manual

range selection
Auto power off

Auto power off

Non-contact voltage detection

Non-contact voltage detection

Built-in flashlight

Built-in flashlight

Contents

16

range selection

Contents

Model AM-520 EUR

Model AM-530 EUR

Test leads

Test leads

1 x Temperature probe

1 x Temperature probe

Carrying case

Carrying case

1 x 9V (6F22) battery (installed)

1 x 9V (6F22) battery (installed)

Users manual

Users manual

Hang strap

Hang strap

DMM

AM-550-EUR
DMM TRMS

1000V AC/DC
10A AC/DC
n Low pass filter for variable
frequency drives
n Capacitance and frequency
measurement
n Temperature measurement
n Automatic and manual
range selection
n Auto power off
n Non-contact voltage detection
n Built-in flashlight

Contents
n Model AM-540 EUR
n Test leads
n 2 x Temperature probe
n Carrying case
n 1 x 9V (6F22) battery (installed)
n Users manual
n Hang strap

Contents
n Model AM-550 EUR
n Test leads
n 2 x Temperature probe
n Carrying case
n 1 x 9V (6F22) battery (installed)
n Users manual
n Hang strap

DM73C

Pen Probe Style


Digital Multi-Tester
600 V AC and 600 V DC ranges
Cat III 300 V safety rated
n Cat II 600 V safety rated
n Improved DC basic
accuracy 0.5%
n Resistance to 34 MW
n Continuity beeper
n Includes alligator clip,
ground test lead, spare probe
tip and installed batteries
n 3400-count digital display
plus analog bargraph
n Auto power off
n UL 3111-1 listedp
n
n

1000V AC/DC
10A AC/DC
n TRMS measurement
n Low pass filter for variable
frequency drives
n Capacitance and frequency
measurement
n Temperature measurement
n Automatic and manual
range selection
n Non-contact voltage detection
n Built-in flashlight

PM55A

Digital Multimeters

AM-540-EUR

Digital Multimeter
AutoTect feature directs the
meter to know if it is measuring
AC volts, DC volts or resistance
with no user interface
n The AutoTect feature has
lower input impedance which
zero out ghost voltages
n Measures AC/DC current,
capacitance, frequency,
continuity with beeper plus
includes Voltect, a built-in,
non-contact voltage detector
n Large oversize digital display
n Protective silicon holster
included, attached test
leads, battery, deluxe
carry case and manual
n One-year, no-hassle warranty
n

17

Temperature Measurement

The Beha-Amprobe series of infrared and


contact thermometers are a complete
line of high performance diagnostic tools
designed for HVAC/R, electrical, industrial
maintenance applications.

18

Infrared Thermometer (10:1)


E xtremely accurate and reliable
P
 recise measurement with
distance to spot ratio 10:1
n W
 ide temperatures
ranges available up to
-0F to 716F
(-18C to 380C )
n R
 apid response time
n L
 aser pointer for accurate targeting
n 8
 seconds auto display
hold for easy read-out
n A
 djustable emissivity for
measuring a variety of materials
n D
 ual LCD display with backlight
n S
 electable F and C
n
n

IR-730-EUR

Infrared Thermometer (30:1)


E xtremely accurate and reliable
P
 recise measurement with
distance to spot ratio 30:1
n W
 ide temperatures
ranges available up to
-26F to 2282F
(-32C to 1250C )
n R
 apid response time
n L
 aser pointer for accurate targeting
n 8
 seconds auto display
hold for easy read-out
n A
 djustable emissivity for
measuring a variety of materials
n D
 ual LCD display with backlight
n S
 electable F and C
n
n

IR-720-EUR

Infrared Thermometer (20:1)


E xtremely accurate and reliable
P
 recise measurement with
distance to spotratio 20:1
n W
 ide temperatures
ranges available up to
-26F to 1922F
(-32C to 1050C )
n R
 apid response time
n L
 aser pointer for accurate targeting
n 8
 seconds auto display
hold for easy read-out
n A
 djustable emissivity for
measuring a variety of materials
n D
 ual LCD display with backlight
n S
 electable F and C
n
n

IR-750-EUR

Infrared Thermometer (50:1)


E xtremely accurate and reliable
P
 recise measurement with
distance to spot ratio 50:1
n W
 ide temperatures
ranges available up to
-58F to 2822F
(-50C to 1550C )
n R
 apid response time
n L
 aser pointer for accurate targeting
n 8
 seconds auto display
hold for easy read-out
n A
 djustable emissivity for
measuring a variety of materials
n D
 ual LCD display with backlight
n S
 electable F and C
n Stores up to 99 data points
n Thermocouple input
n USB interface
n

Temperature Measurement

IR-710-EUR

19

IR-450-EUR

Pocket Infrared Thermometer

IR608A

Infrared Thermometer
Laser Pointer

IR pocket thermometer with

8:1 distance to spot ratio


n

Selectable F / C

Holds temperature

measurement
n

Bright laser pointer

Built-in LED flashlight to

Switchable between C
and F measurement

reading for 10 seconds


n

Non-contact temperature

Integrated measurement
memory (data hold)

illuminate dark areas

Backlight

Distance to spot size ratio: 8:1

Auto power-off

Additional Features
n

Laser-based targeting

Handy and compact


pistol grip design

TMD-50

Thermometer
TMD-50, Type K
Dual (Temperature
measurement with connection
for two sensors)
n -60 to 1350 C, -58 to 2498 F
n Measurement of the
temperature difference
n Connection for two
temperature sensors type K
n Switchable for measurement
in C or F
n Integrated measurement
memory (Data Hold)
n MIN/MAX and relative
value measurement
n Measurement of the
average temperature
n Backlit display
n Auto-Power-Off

TH-3

Relative Humidity
Temperature Meter

20

Additional Features
n Best precision 0.1%
n T1-T2 (temperature
difference)
n Shock and impactresistant by standard
protective cover

Dual display

Relative function monitors

humidity and temperature


changes
n

Extended probe stem to easily

access air ducts


n

Min/Max readings

Data Hold
n

Capacitive sensor with

protective cover
n

Auto Power off

Soft Carrying Case

One-year warranty

Other Test Equipment

Need something a little different? Always


check the Beha-Amprobe range. This section
has a selection of other Beha-Amprobe
test equipment for electrical and HVAC
applications.

21

LAN-1

Lan Cable Tester

LM-100

Light Meter Manual Ranging

Light measurement

0 -200,000 lux

Manual range selection

Silicon sensor

Integrated measurement

Test pin configuration for:


10/100 base -T cable
10 base-2 cable
RJ45 modular cables
AT&T 258A cable
EIA/TIA 568A/568B cables
Token Ring Cable
n Verify the cable wiring for
continuity, opens, shorts or
incorrect wiring
n Test installed cable on wall
plate or the patch panels by
using the Remote
Termination module
n Perform Loopback Test
or Remote Test
n Buzzer sound warning for
error condition in cable
n Two sets of LED lights for
Source and Test indication

memory (data hold, MAX)

TMA10

Anemometer Thermometer
Anemometer with remote vane

 easure CFM by inputting


M
the vent dimensions
n Obtain air flow average by
taking up to eight data points
n Vane has three foot cord for
measurement flexibility
n Deluxe carrying case
n Measure air velocity or air flow
n RS232 interface output
with optional software
and cable, TM-SWA
n Continuous moving average
for up to 2 hours
n

LM-120

Light Meter with


Auto Ranging
n

Measure in Lux or Footcandles,

front panel switchable


n

Measuring Range to 200,000

Lux or 20,000 Foot candles


n

Silicon photodiode

sensor and filter


n

Data Hold to freeze reading

on the digital display


n

MIN / MAX ability to show

high and low readings


n

Autoranging plus Manual Range

Zero function to null

display before a reading


n

22

Auto Power Off to

PRM4

Phase Sequence and Motor


Rotation Tester
n Identifies

3-phase sequence
and open phase check
n Motor shaft rotation indication
protected by CAT III circuitry
n CAT III 600V rated for
both testing segments
n Meets current EN61010 safety
requirements, CSA, EN61557-7
n Supplied with three CAT III
rated color coded large
alligator clips and test leads
n Zippered carrying case
for portability

TACH20

Combo Tachometer

LT-10-EUR
Lamp Tester

Measures rotational
and surface speed
n Built-in memory
n Digital Display
n Auto power off function
n Easy to select units
and mode functions
n Contact and non-
contact measurement
n Select rpm using infrared
beam or adapter: m/min, m/sec,
ft/min, ft/sec, in/min, m, ft, and in.
n Includes 6 Adapters, Carrying
Case, Reflective Tapes,
Batteries and User Manual
n

Determine if fluorescent light


bulbs are operational prior
to installation or removal

Verify voltage presence without


the need for another tool with
built-in VolTect non-contact
voltage detection

Increase productivity
by minimising trips up
and down a ladder

All tests performed with easy,

Ultra-compact design

Industry leading 120cm

single button operation

SM-10

for portability

Sound Meter

retractable antenna
n

Measurement of sound level


n 30-130 dB
n Measurement according to
frequency evaluation filters A
and C, with direct display in dB
n Integrated measurement
memory (data hold, MAX)
n Switchable between fast
and slow response times
n Backlight

for safe testing

PQ55A

Compact Power Analyser


n

Comprehensive real time


monitoring, recording and
analysis of three phase
power systems
True-rms voltage and
current measurement
Power Factor and
phase angle results
Power Analysis (apparent,
active and reactive power)

Insulated antenna sleeve

Others

(48) removable, fully

TX900

Microwave Leakage
Detector
n

Measures for wave leakage

and tests oven power


n

8 dipole sensors allows

detection of plane wave signals


of any polarization
n

Temperature compensation

accurate reading regardless


of ambient temperature changes
n

Compact, ergonomic design

Low battery indication

Analog Bar Graph

Auto-zero

23

Technical Specification
Multi-Function Installation Testers
KTS1625

KMP7100

Specifications (At 23C 5C, 45% to 75% RH)

Specifications (At 23C 5C, 45% to 75% RH)

Insulation Resistance @
250V/500/1000V (Test
Current 1mA)

Operating Voltage

230Vac, 45Hz ~ 65 Hz

+10% to -15%

Earth Loop Impedance 20

0.01 ~ 19.99
@ Nominal Test
Current 25A

(3% rdg + 4 LSD)

Earth Loop Impedance 200

20.0 ~ 199.9
@ Nominal Test
Current 2.3A

(3% rdg + 4 LSD)

Earth Loop Impedance 2000

200 ~ 1999
@ Nominal Test
Current 15mA

(3% rdg + 4 LSD)

Non tripping Loop test 20

0.01 ~ 19.99

(3% rdg + 6 LSD)

Non tripping Loop test 200

20.0 ~ 199.9

(3% rdg + 7 LSD)

Prospective Short Circuit


Current (PSC)
200A / 2000A / 20kA

0.0 ~ 199.9 /
1999 / 19.9kA

PSC accuracy derived


from measured loop
impedance specification
and measured
voltage specification

Continuity @ IN 200mA,
Uo=5Vdc (Nominal)

0.00 ~ 199
(Buzzer threshold: 20)

(2% rdg + 5 LSD)

AC Voltage Measurement

0Vac ~ 400Vac

(5% rdg + 2 LSD)


@ 45 to 65Hz

Operating Voltage
(Loop and RCD)

230Vac, 45Hz ~ 65 Hz

+10% to -15%

Line Impedance (L N) @ 25A

0.01 ~ 1.99 / 2.0 ~ (5% rdg + 5 LSD)


19.9 / 20 ~ 2000

Loop Impedance
(L PE) @ 25A

0.01 ~ 1.99 / 2.0 ~ (5% rdg + 5 LSD)


19.9 / 20 ~ 2000

Loop impedance without


tripping @ 15mA

0.01 ~ 1.99 / 2.0 ~ (5% rdg + 12 LSD


19.9 / 20 ~ 2000
+ Noise Margin
(0.01 - 1.99))

RCD Test Current

10/30/100/300/500mA

0% to 10% @
1n and 5n
-10% to 0% @ n

Prospective Short Circuit


Current (PSC) @ 25A

PSC accuracy derived


from measured loop
impedance specification
and measured
voltage specification

RCD Trip Times @ X

0 ~ 2000ms
(10/30/100/300/500mA)

(1% rdg + 2 ms)

Prospective Earth Fault


Current (PSC) @ 25A

0.00A ~ 1.99A / 2.0A


~ 19.9A / 20A ~ 199A
/ 200A ~ 1.99kA
/ 2.0kA ~ 26kA

RCD Trip Times @ X1

0 ~ 1000ms (selective)
(10/30/100/300/500mA)

(1% rdg + 2 ms)

RCD Test Current

10/30/100/300/500mA

0% to 10% @
1n and 5n
-10% to 0% @ n

RCD Trip Times @ X1

0 ~ 1000ms
(10/30/100/300mA)

(1% rdg + 2 ms)

RCD Trip Times @ X5

0 ~ 2000ms
(10/30/100/300/500mA)

(1% rdg + 2 ms)

0 ~ 40ms
(10/30/100mA)

(1% rdg + 2 ms)

RCD Trip Times @ X

RCD Auto Test

RCD Trip Times @ X1

0 ~ 500ms (selective)
(10 / 30 / 100 /
300 / 500mA)

(1% rdg + 2 ms)

X / X1 / X5 (10
/ 30 / 100mA)

RCD Trip Times @ X1

0 ~ 300ms (10 / 30
/ 100 / 300mA)

(1% rdg + 2 ms)

Trip time: (1%


rdg + 2 ms)
Trip current: 0% to
10% @ 1n and 5n
-10% to 0% @ n

RCD RAMP Test

RCD Trip Times @ X5

0 ~ 40ms (10 /
30 / 100mA)

(1% rdg + 2 ms)

X / X1 / X5 (10 / 30
/ 100 / 300 / 500mA)

RCD Auto Test

X / X1 / X5 (10
/ 30 / 100mA)

Trip time: (1% rdg +


2 ms) Trip current: 0%
to 10% @ 1n and 5n
-10% to 0% @ n

50% ~ 110% Default


nominal residual
currents (In).
Increasing by 10%,
total 7 steps of
residual current

Fault Voltage Detection


(N PE conductor)

Selectable 25V or 50Vac

Voltage Measurement

0Vac ~ 600Vac

Operating Temperature

0C to +40C, 85% RH, no condensation

Storage Temperature

-20C to +60C, 90% RH, no


condensation (without batteries)

Power Supply

1.5V Alkaline Battery (AA Battery) 8 pcs

Dimensions (L x W x H)

189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)

RCD RAMP Test

24

0.00M ~ 250M
(5% rdg + 5 LSD)
@ 250V
0.00M ~ 500M
@ 500V
0.00M~1000M
@ 1000V
(Buzzer threshold: 2M)

X / X1 / X5 (10 / 30
/ 100 / 300 / 500mA)

50% ~ 110% Default


nominal residual
currents (In).
Increasing by
10%, total 7
steps of residual current

(2% rdg + 3 LSD)


@ 45Hz ~ 65 Hz

Fault Voltage Detection


(N PE conductor)

50Vac or more

Operating Temperature

0C to +40C, 85% RH, no condensation

Product Weight

Approx. 450g (0.99 lb)

Storage Temperature

-20C to +60C, 90% RH, no


condensation (without batteries)

Regulation Compliance

Power Supply

1.5V Alkaline Battery (AA Battery) 8 pcs

Dimensions (L x W x H)

189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)

Product Weight

Approx. 1.3 kg (2.87 lb) with batteries installed

Designed to allow testing to BS7671


IEE 17th Edition regulations
BS EN 61010-1 CAT III 300V
BS EN 61557-1 / -3 / -6 / -10
BS EN 61326-1 (EMC)

Regulation Compliance

Designed to allow testing to BS7671


IEE 17th Edition regulations
BS EN 61010-1 CAT III 300V
BS EN 61557-1 / -2 / -3 / -4 / -6 / -10
BS EN 61326-1 (EMC)

Included Accessories

3-wires mains test cord with UK plug, test leads


(red, black green), test probes (red, black,
green), alligator clips (red, black, green),
users manual, strap and carrying case

Included Accessories

3-Wires mains test cord set, test lead (red,


black green), test probe (red, black, green),
alligator clips (red, black, green), Test probe
with Remote Test Button, users manual,
strap and carrying case

Single-Function Installation Testers


KMP7020/KMP7021

KMP7030
Specifications (At 23C 5C, 45% to 75% RH)

Operating Voltage

230Vac, 50 Hz

+10% to -15%

Trip current @ X

10/20/30/100/300/500mA Trip current tolerance:


(trip time 0 to 2000ms) -10% to +10%
Trip Time: (2%
rdg + 2 LSD)

Trip current @ X1

10/20/30/100/300mA
(trip time 0 to 1000ms)
500mA (trip time
0 to 300ms)

Trip current tolerance:


0% to +10%
Trip Time: (2%
rdg + 2 LSD)

Trip current @ X5

10/20/30mA (trip
time 0 to 40ms)

Trip current tolerance:


0% to +10%
Trip Time: (2%
rdg + 2 LSD)

Fast Trip Current (KMP7020)

250mA (trip time


0 to 40ms)

Trip current tolerance:


0% to +10%
Trip Time: (2%
rdg + 2 LSD)

Ramp Test (KMP7021)

10/20/30/100/300/500mA -10% to +10%


Ramp increase by 10%
Default nominal residual currents
from 20% to 110%
Maximum measuring time 300ms x 10 times

Operating Temperature

0C to +40C, 80% RH, no condensation

Storage Temperature

-20C to +60C, 90% RH, no condensation

Power Supply

AC mains 230V +10% -15%, 50 Hz

Dimensions (L x W x H)

160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)

Product Weight

Approx. 450g (0.99 lb)

Regulation Compliance

Designed to allow testing to BS7671


IEE 17th Edition regulations
BS EN 61010-1 CAT III 300V
BS EN 61557-1, BS EN 61557-6
BS EN 61326-1 (EMC)

Included Accessories

3-Wires Mains Test Cord, Test Lead Set,


Users Manual, Strap and Carrying case

KMP7010

230Vac, 45Hz ~ 65 Hz

+10% to -15%

Loop Impedance 20
/ 200 / 2000

0 ~ 19.99 / 199.9
/ 1999

(3% rdg + 4 LSD)

AC Test Current

25A Nominal at 20

AC Test Period

10ms at 20

No Trip Loop Impedance


20 / 200

0 ~ 19.99 / 199.9 (L
(3% rdg + 6 LSD)
N impedance > 20 )

PSC Measurement 200A


/ 2000A / 20kA

0.0 ~ 199.9 /
1999 / 19.9kA

PSC accuracy derived


from measured loop
impedance specification
and measured
voltage specification

Voltage Measurement

100Vac ~ 300Vac

(2% rdg + 4 LSD)


@ 50/60Hz

Operating Temperature

0C to +40C, 85% RH, no condensation

Storage Temperature

-20C to +60C, 90% RH, no


condensation (without batteries)

Power Supply

1.5V Alkaline Battery (AA Battery) 8 pcs

Dimensions (L x W x H)

189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)

Product Weight

Approx. 450g (0.99 lb)

Regulation Compliance

Designed to allow testing to BS7671


IEE 17th Edition regulations
BS EN 61010-1 CAT III 300V
BS EN 61557-1, BS EN 61557-3
BS EN 61326-1 (EMC)

Included Accessories

Mains Test cord with Earth Probe,


Batteries (8 x AA), Users Manual,
Strap and Carrying Case

KMP7036

Specifications (At 23C 5C, 45% to 75% RH)

Specifications (At 23C 5C, 45% to 75% RH)

Earth Resistance Measurement

0.00 ~ 40.00
0.0 ~ 400.0
0 ~ 4000

(2% rdg + 20 LSD)


(2% rdg + 3 LSD)
(2% rdg + 3 LSD)

Voltage Measurement

0Vac ~ 400Vac

(1% rdg + 6 LSD)


@ 50 / 60 Hz

Operating Temperature

+5C to +40C, 80% RH, no condensation

Storage Temperature

-20C to +60C, 90% RH, no


condensation (without batteries)

Power Supply

1.5V Alkaline Battery (AA Battery) 6 pcs

Dimensions (L x W x H)

160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)

Product Weight

Approx. 500g (1.1 lb) with batteries installed

Regulation Compliance

Designed to allow testing to BS7671


IEE 17th Edition regulations
BS EN 61010-1 CAT III 400V
BS EN 61557-1, BS EN 61557-5
BS EN 61326-1 (EMC)

Included Accessories

Operating Voltage

Technical Specification

Specifications (At 23C 5C, 45% to 75% RH)

Three Test Leads (Green, Yellow and Red),


Auxiliary ground rods, Two test leads with
alligator clips, Batteries ( 6 x AA), Users
Manual, Strap and Carrying case

Insulation Resistance @
250V/500/1000V (Test
Current 1mA)

0.00M ~ 4.99M
5.0M ~ 49.9M
50M ~ 999M
1.00G ~ 1.99G
(Buzzer threshold: 4M)

(3% rdg + 5 LSD) for


0.00M ~ 99.9M
(5% rdg + 5 LSD) for
100M ~ 1.99G

Continuity @ IN 200mA,
Uo=5Vdc (Nominal)

0.00M ~ 9.99 M
10.0M ~ 99.9 M

(2% rdg + 5 LSD)

AC Voltage Measurement

30Vac ~ 750Vac

(2% rdg + 3 LSD)


@ 50 / 60Hz

Operating Temperature

0C to +35C, 75% RH, no condensation

Storage Temperature

-20C to +60C, 80% RH, no


condensation (without batteries)

Power Supply

1.5V Alkaline Battery (AA Battery) 6 pcs

Dimensions (L x W x H)

160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)

Product Weight

Approx. 450g (0.99 lb) with batteries installed

Regulation Compliance

Designed to allow testing to BS7671


IEE 17th Edition regulations
BS EN 61010-1 CAT III 600V
BS EN 61557-1 / -2 / -4 / -10
BS EN 61326-1 (EMC)

Included Accessories

Test Leads (red, black), probes (red, black),


alligator clips (red, black), Battery, Instruction
Manual, Carrying case, Strap

25

Technical Specification
Clamp-on Meters
Clamp Multimeter Comparison Guide

Measurement Ranges

Display
Current AC
Tolerance
Frequency Range
Current DC
Tolerance
Voltage AC
Tolerance
Frequency Range
Voltage DC
Tolerance
Continuity
Frequency
Resistance
Tolerance
Capacity
Active Power
Cos Phi
Harmonics
Jaw Opening
Pollution Degree
Features

Overvoltage Category
Safety
Power Supply
Dimensions
Weight

ACD-14 Plus
ACDC-400
ACD-20SW
LCD, 33/4-digit,
LCD, 3 Digit,
LCD, 3 Digit,
4000 digits
3999 Count
3999 Count
0.01 - 600 A
0.01 A - 400 A
0.01 - 400 A
(1.9% rdg. + 8 digits) (1.5% rdg. +3 Digits) (2% rdg +6 Digits)
50/60 Hz
50/60 Hz
50-60 Hz
0.01 A - 400 A
(1.5% rdg. +3 Digits)
0.001 - 600 V
0.1 mV - 600 V
1.0 mV-600,0 V
(1.5% rdg. + 5 digits) (1% rdg. +3 Digits) (1.2% rdg +5 Digits)
50 - 400 Hz
50 - 500 Hz
50 - 500 Hz
0.1 - 600 V
0.1 mV - 600 V
0.1 mV - 600 V
(0.5% rdg. + 3 digits) (0.8% rdg. +2 Digits) (0.5% rdg +2 Digits)
R < 120
R < 40
R < 25
0.001 Hz - 100 kHz
0.1 - 40.00 M
0.1 - 40 M
0.1 - 40 M
(0.8% rdg. + 6 digits) (1% rdg. +3 Digits) (1.0% rdg +4 Digits)
0.1 nF - 3000 F
26 mm
2

30 mm
2

CAT III/600 V
EN 61010/IEC 61010
2 x 3 V battery,
IEC CR2032
190 x 63 x 32 mm
approx. 200 g

30 mm
2

CAT III/600 V

CAT lll/600 V

DIN VDE 0411,


EN 61010, IEC 61010
2 x Battery 1.5 V,
IEC LR03
205 x 64 x 39 mm
approx. 280 g

DIN VDE 0411,


EN 61010/IEC 61010
2 x Batterie 1.5 V,
IEC LR03
240 70 41 mm
approx. 220 g

Clamp Multimeter Comparison Guide

Measurement Ranges

Display
Current AC
Tolerance
Frequency Range
Current DC
Tolerance
Voltage AC
Tolerance
Frequency Range
Voltage DC
Tolerance
Continuity
Frequency
Resistance
Tolerance
Capacity
Active Power
Cos Phi
Harmonics
Temperature
Input Impedance
Jaw Opening
Pollution Degree
Features

Overvoltage Category

26

Safety
Power Supply
Dimensions
Weight

ACDC-54NAV
LH41
AC50A
LCD, 3 Digit,
LCD, 3 Digit,
LCD, 3 Digit,
4000 Count
4000 Count
3999 Count
0.01-1000 A
0.001 - 40 A
0.01 mA - 60 A
(1.5 % rdg. +5 Digits) (1.3 % rdg. +5 Digits) (1.5% rdg. +5 Digits)
50 Hz - 400 Hz
40 - 400 Hz
40 Hz - 1 kHz
0,001 - 40 A
(1.3 % rdg. +5 Digits)
0,01 - 1000 V
0,1 - 400 V
(1 % rdg. +5 Digits)
(2% rdg. + 4 Digits)
50 - 500 Hz
40 Hz - 1 kHz
0.01 - 1000 V
(0.7% rdg. +2 Digits)
R < 30
R < 40
20.00 - 9.999 kHz
0.199.99 k
0.1 - 400
(1% rdg. +5 Digits)
(1% rdg. +2 Digits)
0 - 999.9 kW
-1.000.00 +1.00
display up to the 25th
-50 C-1000 C
10 M
37 mm
2
CAT IV 600V,
CAT III 1000V
DIN VDE 0411,
EN 61010/IEC 61010
1 x battery 9 V,
IEC 6F22
260 x 80 x 40 mm
approx. 480 g

19 mm
2

30 mm
2

CAT III/600 V

CAT III/600 V

DIN VDE 0411,


DIN VDE 0411
EN 61010, IEC 61010 EN 61010, IEC 61010
1 x Battery 9 V,
2 x Battery 1.5 V,
IEC 6LR61
IEC LR6
184 x 71 x 31 mm
210 x 62 x 36 mm
approx. 235 g
approx. 200g

ACDC-100
ACD-50NAV
LCD, 3 Digit,
LCD, 3 Digit,
4000 Count
4000 Count
0.1 A - 800 A
0.01 - 600 A
(1.5% rdg. +5 Digits) (1.5 % rdg. +5 Digits)
50 Hz - 400 Hz
0.1 A - 1000 A
(1.5% rdg. +4 Digits)
0.1 mV - 600 V
0.01 - 1000 V
(1% rdg. +4 Digits) (1 % rdg. +5 Digits)
50 - 500 Hz
50 Hz - 500 Hz
0.1 mV - 600 V
0.01 - 1000 V
(0.5% rdg. +3 Digits) (0.7 % rdg. +2 Digits)
R < 120
R < 30
20,00 - 9,999 kHz
0.1 - 40.00 M
0.199.99 k
(0.8% rdg. +6 Digits)
0 - 600.0 kW
-1.000.00 +1.00
display up to the 25th
50 mm
2

37 mm
2
CAT IV 600V,
CAT III/600 V
CAT III 1000V
DIN VDE 0411,
DIN VDE 0411,
EN 61010, IEC 61010 EN 61010, IEC 61010
2 x Battery 1.5 V,
1 x Battery 9 V,
IEC LR03
IEC 6F22
227 x 78 x 40 mm
260 x 80 x 40 mm
approx. 290 g
approx. 480 g

Digital Multimeters
AM-500-EUR

Events

Display

Features

Functions

MULTIMETER TYPE
Safety Rating

Safety

Measure voltage in noisy environments


Electrical panels, AC outlets
DC systems, auto/marine batteries
AC Current - electrical panels, appliances
DC Current - electronics, DC motors
Specified resistance and continuity
Flame sensors
Diodes in AC to DC converters
Fuses, lightbulbs, wire connections
Household batteries
Motor startup or run capacitors
Frequency verification
Non-contact voltage test
Electrical load-time on vs time off
Temp of air vents, fuses, transformers

True-rms
AC Voltage (V)
DC Voltage (V)
AC Current (A)
DC Current (A)
Resistance (MOhms)
Microamps
Diode Test
Continuity
Battery test
Capacitance
Frequency
Non-contact voltage
Duty cycle
Temperature inputs

Automatically selects measurement range


Manually select measurement range
Voltage on variable frequency drives
Detect stray voltages
Dimly lit areas

Autoranging
Manual ranging
Low pass filter
Low Z
Built-in flashlight

Meter resolution
Dimly lit areas
Monitoring fast changing signals
Two relative measurements on one screen

LCD Counts
Backlight
Bar graph
Dual display

Data memory
Difference between two measurements
Max/min peak measurement
Specialised signal measurements

Data hold
Relative reading
Max/min hold
Peak hold (crest)

AM-510-EUR

AM-520-EUR

AM-530-EUR

AM-540-EUR

AM-550-EUR

Autoranging

Com / Res

HVAC

Electrical

Adv. HVAC

Industrial

CAT III 600V

CAT III 600V

CAT III 600V


CAT II 1000

CAT III 600V


CAT II 1000

CAT IV 600
CAT III 1000

CAT IV 600
CAT III 1000

600
600
10
10
20

600
600
10
10
40

750
1000
10
10
40

750
1000
10
10
40

1000
1000
10
10
60

1000
1000
10
10
60

1
n

n
n

2,000

4,000

4,000

4,000

6,000

6,000

Portable Appliance Testers


GT-400-UK

Technical Specification

Series Selection Guide

Specifications GT-400-UK
Protective conductor resistance
Insulation resistance
Substitute leakage current
Supplied with

0.10 ... 2.00 (5% + 10 digits)


0.100 ... 9.999 M, 10.00 ... 20.00 M (5% + 2 Digits)
0.100 ... 9.999 mA, 10.00 ... 20.00 mA (5% + 2 Digits)
Test leads, alligator clip, test probe, IEC lead, carrying
case, 6 AA batteries, users manual

Protective Conductor Resistance


Measuring range
Display range
Resolution
Tolerance
Measuring current / voltage

0.10 ... 2.00


0.05 ... 2.00
0.01
(5% + 10 digits)
Min. 200 mA DC / > 4 V

Insulation Resistance
Measuring range
Display range
Resolution
Tolerance
Measuring current / voltage

0.1 ... 20 M
0.1 ... 20 M
0.1 ... 9.999 M 0.001 M / 10.00 ... 20.00 M 0.01 M
(5% + 2 digits)
Min. 500 V DC / >1 mA

Substitute Leakage Current


Measuring range
Display range
Resolution
Tolerance
Measuring current / voltage

0.1 ... 20 mA
0.1 ... 20 mA
0.1 ... 9.999 mA 0.001 mA / 10.0 ... 20.00 mA 0.01 mA
(5% + 2 digits)
Approximately 32 V AC

General Specifications
Power supply
Degree of pollution
Overvoltage category
Protection degree
Protection class
Electrical safety
EMC emission
EMC interference resistance
Dimensions (L x W x H)
Weight

6 x 1.5 V Batteries (IEC LR6 (AA)


6 x 1.2 V NiMH rechargeable batteries
2
CAT II 300 V
IP40
II
EN61010-1/VDE0411
EN61000-6-3
EN61326-1
Approximately 265 x 110 x 50 mm
Approximately 700 g

27
Subject to change

Robin-Amprobe Test Tools UK


52 Hurricane Way, Norwich, Norfolk, NR6 6JB, United Kingdom
Web: www.robin-amprobe.co.uk / www.beha-amprobe.com
Email: info@robin-amprobe.co.uk
Phone: +44 (0) 1603 25 6662 Fax: +44 (0) 1603 25 6664
12162-eng

Вам также может понравиться