Вы находитесь на странице: 1из 2

GS 04

Forked photoelectric sensors

en 03-2010/11 50110846

Dimensioned drawing

20/30/50/80/120/220mm
10 - 30 V
DC

1,5 kHz

We reserve the right to make changes DS_GS_04_M_P_N_en.fm

z Sensitivity adjustment and light/dark


switching for optimal adaptation to the
application
z Sensitivity adjustment on the back of the
fork
z Robust metal housing and glass optics for
protection against environmental
influences
z Transmitter and receiver are installed in the
same housing, therefore easy and fast
mounting (excessive mounting brackets
and extensive alignment not necessary)

UL

A
B
C
D

Optical axis
Sensitivity adjustment
Light/dark switching
Indicator diode

GS 04M/-20
GS 04M/-30
GS 04M/-50
GS 04M/-80
GS 04M/-120
GS 04M/-220

E
Mw
20
30
50
80
120
220

F
Mt
24
34
54
54
54
114

F1

25
25
25
25
30
30

49
59
79
79
84
144

40
50
70
100
140
240

6
12
12
12
37
37

4,5
4,5
4,5
4,5
-

12,5
12,5
12,5
12,5
18
18

4,5
4,5
4,5
22
22

4,5
4,5
4,5
4,5
5
5

20
20

Electrical connection
US

LISTED

IEC 60947...

IEC 60947...

IP 67

GS 04 M/P ....

GS 04 M/N ....

Accessories:
(available separately)

z M8 connectors (KD )
z Cable with M8 connector (K-D...)

Leuze electronic GmbH + Co. KG


info@leuze.de www.leuze.com

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

GS 04 M/ - 03

GS 04
Specifications

Tables

Optical data
Mouth width
Light source
Wavelength

20/30/50/80/120/220mm
LED (modulated light)
640nm red light

Timing
Switching frequency
Response time
Delay before start-up

1500Hz
0.33ms
100ms

Electrical data

Operating voltage UB 1) 2)
Residual ripple
Open-circuit current
Switching output
Function characteristics
Signal voltage high/low
Output current
Sensitivity

10 30VDC (incl. residual ripple)


15% of UB
35mA
PNP/NPN transistor output
light/dark switching reversible
(UB -2V)/ 2V
200mA
adjustable (potentiometer, adjustment range 0 270)

Indicators
Red LED

state of switching output

Mechanical data
Housing
Weight
Optics cover
Connection type

diecast zinc
see order guide
glass
M8 connector, 3-pin

Environmental data
Ambient temp. (operation/storage)
Protective circuit 3)
VDE safety class
Protection class
Certifications
1)
2)
3)
4)

Diagrams

-10C +60C/-20C +70C


1, 2
III
IP 67
UL 508 4)

Functional extra-low voltage with reliable disconnection or protective extra-low voltage (VDE 0100/T 410)
Observe the safety regulations and installation instructions regarding power supply and wiring
1=polarity reversal protection, 2=short-circuit protection for all outputs
For UL applications: for use in class 2 circuits according to NEC only

Mouth width [mm]


20
30
50
80
120
220

Smallest detectable object [mm]


0,3
0,3
0,4
0,4
0,5
0,6

Reproducibility [mm]
0,02
0,02
0,04
0,06
0,08
0,08

Switching hysteresis [mm]


0,1
0,1
0,15
0,2
0,2
0,2

GS 04 M/ - 03

50
54
z

50
54

80
77
z

80
77

GS 04M/N-220-S8
Part No. 501 10788

30
36

GS 04M/P-220-S8
Part No. 501 10786

30
36
z

GS 04M/N-120-S8
Part No. 501 10787

20
28
z

GS 04M/P-120-S8
Part No. 501 10785

GS 04M/N-80-S8
Part No. 501 10790

PNP
NPN

GS 04M/P-80-S8
Part No. 501 10784

Equipment
Mouth width [mm]
Weight in g
Transistor output

GS 04M/N-50-S8
Part No. 501 10789

Order code

GS 04M/P-50-S8
Part No. 501 10783

Approved purpose:
GS 04M/N-30-S8
Part No. 501 10791

Selection table
GS 04M/P-30-S8
Part No. 501 10782

Remarks
GS 04M/P-20-S8
Part No. 501 10792

Order guide

The forked photoelectric


sensors are optical electronic
sensors for optical, contactless detection of objects.