Edition 2011-11_1
Sigunit D
Sigunit D
Construction
Uses
Sigunit D is suitable for dry spray gunite mixes of both mortar and concrete such as
those required for:
Tunnels
Galleries
Securing rock-faces
Embankments
Excavations
Thin section concrete shells
Swimming pools
Concrete repair works
Strengthening concrete structures
Characteristics /
Advantages
Sigunit D reacts in the mix to assist the hydration process, resulting in greatly
accelerated strength development within the first 24 hours. Other benefits include:
Improved watertightness
Simplified overhead spraying
Reduced rebound
Better adhesion to areas of slight seepage
Chloride free
High compressive and flexural strength
Quick setting and hardening
Product Data
Form
Appearance / Colours
White powder
Packaging
20 kg bags
Storage
Storage Conditions /
Shelf Life
6 months from the date of production if stored properly in original, unopened and
undamaged sealed packaging in dry conditions at temperatures between +5C and
+30C.
Technical Data
Chemical Base
Sigunit D
1/2
Typical Results
Design Mix
Cement type
W/C ratio
Temperature
OPC
0.35
+20C
Setting Time, minutes : seconds
Dosage, %
Initial
Final
3.0
8 : 20
10 : 00
4.0
3 : 10
8 : 20
5.0
2 : 10
5 : 00
6.0
1 : 30
2 : 40
7.0
1 : 00
1 : 30
Construction
System Information
Application Details
Dosage
Application Instructions
Dispensing
The required quantity of Sigunit D is added to the dry sand / cement or dry sand /
cement / chippings at the last moment, for example at the mixing rotor.
Cleaning of Tools
Clean all tools and application equipment with water immediately after use.
Hardened and/or cured material can only be removed mechanically.
Notes on Application /
Limitations
Rates of set for gunite mixes are slowed down when using cold materials or when
spraying onto cold substrates.
The type and age of the cement could also be an influencing factor. Therefore, it is
advisable to carry out trial mixes to determine the correct dosage rate.
Value Base
All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.
For information and advice on the safe handling, storage and disposal of chemical
products, users should refer to the most recent Material Safety Data Sheet (available
on request) containing physical, ecological, toxicological and other safety-related
data.
Legal Notes
Sigunit D
2/2