For more than 3 years antsLABTM has built an enviable reputation for innovative design,
advanced technology and outstanding quality in the field of electric furnaces for
research, quality control and plant applications.
The Ants philosophy is to match proven design
with quality at every stage. Only the finest
materials are used and every component is
tested throughout production to ensure that our
products operate efficiently over a long working
life.
This brochure contains details of our
range of standard laboratory furnaces,
including Chamber, Tube, and Split Tube
designs.
2-3
3
4-5
6-7
8-9
10
FURNACE ACCESSORIES
7. Temperature sensing thermocouple and
digital display (150oC-1700oC)
11
2
Laboratory Chamber Furnaces (750oC-1200oC)
A robust range of laboratory furnaces, providing an excellent
level of versatility without compromising quality, safety or
reliability.
All units in this range have a continuous operating
temperature of 1200C. Heating is provided by two side-wall free
radiating elements manufactured from original Swedish Kanthal
high temperature resistance wire spirals supported on
recrystallized Alumina tubes for optimum uniformity. Free
radiating elements provide option of fast heating the furnace up
to 20oC/min.
The special swivel type door opens outwards keeping the hot face insulation away from the
operator. All units use vacuum formed fiber board low thermal mass insulation for fast, accurate
heating and cooling. The use of double skin construction allows natural air convection to maintain
a cool outer case. An exhaust chimney is fitted on optional basis.
Furnace entrance door is made from hard wearing Alumina bricks to handle wear over long life.
Modular design with easy access to elements & controls simplifies maintenance & servicing.
Optional Extras
Metal retorts A variety of metal retorts are available for use with this range of furnaces.
This type of retort is generally used to cater for the following process conditions:
a. To maintain controlled atmospheres within the heated chamber;
b. To protect the heating elements and insulation from chemical attack by aggressive
volatiles given off by fluxes, acids, etc.
Four sided heating This option upgrades the standard two sided heating to four sided heating
and is recommended in the following circumstances:
a. For use with metal retorts and ceramic liners;
b. To improve chamber temperature uniformity to meet specific process requirements;
c. To up rate the furnace power to cope with large loads.
3
R-Type thermocouple This option upgrades the standard K Type (mineral insulated inside
Inconel sheath) thermocouple to R-Type thermocouple and is recommended if furnace is going to
be used continuously at 1200oC.
Over-temperature protection This option is recommended to protect valuable contents & for
unattended operation.
Data logging and remote controlled controllers A range of sophisticated digital controllers,
multi-segment programmers and data loggers is available. These can be fitted with RS232 and
RS485.
Code
Maximum
Temp (oC)
Continuous
Operating
Temp (oC)
Time to
Temp
(minutes)
Internal
Dimension
(mm) hxwxd
External
Dimensions
(mm) hxwxd
Chamber
Sensing
Capacity Thermocou(Lt.)
ple
M1S11
1200
1100
55
150x150x200 725x470x475
4.5
3.4
M2S11
1200
1100
75
200x200x300 775x520x575
4.5
3.8
M1S12
1225
1200
65
150x150x200 725x470x475
12
6.2
M2S12
1225
1200
85
200x200x300 775x520x575
12
7.0
Power
(kW)
Code
Maximum
Temp (oC)
Continuous
Operating
Temp (oC)
Time to
Temp
(minutes)
Internal
Dimension
(mm) hxwxd
External
Dimensions
(mm) hxwxd
Chamber
Sensing
Capacity Thermocou(Lt.)
ple
M1E11
1150
1100
55
150x150x200 450x470x525
4.5
3.6
M2E11
1150
1100
75
200x200x300 500x520x625
12
6.6
Power
(KW)
4
High Temperature Chamber Furnaces (1200oC-1600oC)
A range of advanced high temperature general purpose chamber furnaces for use in both laboratory and light production applications.
5
Optional Extras
controllers, multi-segment programmers and data loggers is available. These can be fitted with
RS232 and RS485.
Code
Maximum
Temp (oC)
Continuous
Operating
Temp (oC)
Time to
Temp
(minutes)
Internal
Dimension
(mm) hxwxd
External
Dimensions
(mm) hxwxd
Chamber
Sensing
Capacity Thermocou(Lt.)
ple
M1S14
1400
1350
135
150x150x250 790x565x570
5.6
3.7
M2S14
1400
1350
135
200x200x300 840x615x670
12
6.2
M1S14
1425
1400
140
150x150x250 790x565x570
5.6
4.3
M2S14
1425
1400
140
200x200x300 840x615x670
12
6.7
M1S16
1600
1500
160
150x150x200 760x555x550
4.5
4.5
M2S16
1600
1500
160
200x200x300 810x605x650
12
6.5
Power
(kW)
Continuous
Short Term
Low
High
Low
High
750
-180
800
1100
-180
1300
1600
-50
1700
200
1700
1820
6
Laboratory Tube Furnace (750oC 1200oC)
For laboratory processes requiring the use of a tube furnace, Ants offers a variety of tube
diameters and lengths to meet most heat processing requirements.
Furnace insulation - Low thermal mass insulation is used throughout for rapid response rates
and maximum thermal efficiency and stability. A rugged metal sheathed thermocouple is
protected from accidental damage and allows full use of the work tube bore. In furnace were work
tube is integral part of furnace, a separate work tube is required when furnace is used with an
atmosphere or is likely to be contaminated by spillage. Tubes Insulating end plugs to minimise
heat loss and thermal gradients is offered as standard.
Over-temperature protection This option is recommended to protect valuable contents & for
unattended operation.
Data logging and remote controlled controllers A range of sophisticated digital controllers,
multi-segment programmers and data loggers is available. These can be fitted with RS232,
RS485.
7
Optional fittings include:
A wide range of tubes
Gas tight end fittings for work in controlled atmospheres
For increased uniform temperature zone length, three zone versions are available
Vacuum pump and related accessories
R-Type thermocouple this option upgrades the standard K Type (mineral insulated inside
Code
Maximum
Temp (oC)
Continuous
Operating
Temp (oC)
Time to
Temp
(minutes)
Outer Diameter
of Hot ZoneTube (mm)
Length of
Hot Zone
(mm)
External
Dimensions
(mm) hxwxl
Sensing
Thermocou- Power
ple
(kW)
T1S11
1200
1150
55
40
200
665x445x480
2.0
T2S11
1200
1150
70
60
250
685x465x530
3.2
T1S12
1225
1200
60
40
200
665x445x480
2.5
T2S12
1225
1200
75
60
250
685x465x530
3.8
OD
(mm)
ID
(mm)
Length (mm)
Quartz
40+/-1
37+/-1
Upto 2000mm
60+/-1
55+/-1
Upto 2000mm
40+/-2
32+/-2
Upto 1500mm
60+/-2
52+/-2
Upto 1500mm
40+/-2
32+/-2
Upto 1500mm
60+/-2
50+/-2
Upto 1500mm
80% Alumina
8
High Temperature Tube Furnace (1200oC 1600oC)
Furnace 1200oC 1400oC
These models have a continuous operating temperature of 1350C and 1400C
Furnace
9
This range of furnaces has a maximum operating temperature of 1600C. For operation at 1600
C and above work tube of 99.5% recrystallised Alumina is recommended.
Maximum
Temp (oC)
Continuous
Operating
Temp (oC)
Time to
Temp
(minutes)
Outer Diameter
of Hot ZoneTube (mm)
Length of
Hot Zone
(mm)
External
Dimensions
(mm) hxwxl
Sensing
Thermocou- Power
ple
(kW)
T1S11
1400
1350
120
60
250
745x525x645
4.0
T2S11
1425
1400
130
60
250
745x525x645
4.8
T1S12
1600
1500
150
60
300
755x535x655
4.0
10
Split Tube Furnace (1100oC 1600oC)
This enables easy access where work tubes are to be changed between jobs or where the
furnace is to be wrapped around the sample for example in tensile test rigs.
ANTS VALUES
Never Give Up
Team Work
Planning and Organization
Humility
Sharing